• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • Tagged with
  • 33
  • 33
  • 33
  • 17
  • 16
  • 14
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da lipocalina associada à gelatinase de neutrófilos (NGAL) em idosos após osteossíntese de fêmur /

Andrade Neto, José de Souza. January 2015 (has links)
Orientador: Noma Sueli Pinheiro Modolo / Banca: Luiz Antonio Vane / Banca: Vera Lucia Fernandes de Azevedo / Resumo: Introdução: A lesão renal aguda (LRA) ocorre em 23% dos pacientes hospitalizados. É responsável por alta morbimortalidade e, ainda assim, não há um marcador precoce e acurado de diagnóstico. Pacientes idosos estão em risco e frequentemente desenvolvem LRA no pós-operatório de grandes cirurgias ortopédicas. Objetivos: Avaliar o biomarcador NGAL plasmático como preditor precoce de LRA no período pós-operatório de fratura de fêmur em idosos. Método: 57 pacientes idosos submetidos à operação de correção de fratura de fêmur foram estudados prospectivamente após 48 horas do pós-operatório. Amostras de sangue foram coletadas para análise de NGAL logo ao término da cirurgia, no período de 4 e 24 horas depois. Amostras da creatinina foram coletadas na admissão hospitalar, 24 e 48 horas no pós-operatório. Foi analisada a acurácia da molécula de NGAL para diagnóstico de LRA. Resultados: Dezesseis (28%) pacientes desenvolveram LRA e apresentaram valores mais elevados de NGAL no plasma com diferença estatística significativa. A análise da área sob a curva Receiving Operator Characteristic demonstrou em 4 horas valor de 0.799 (0.663 a 0.936, p< 0,001); em 24 horas valor de 0.805(0.665 a 0.946, p<0,001). Conclusão: A molécula de NGAL apresentou uma boa acurácia para predição de LRA quando medido após 4 e 24 horas do período pós-operatório / Abstract: Introduction: Introduction: Acute kidney injury is common in hospitalized patients undergoing surgical procedures. It is responsible for a high mortality and yet, there is no early and reliable diagnostic marker. Elderly patients are at risk and often undergo orthopedic procedures as surgical repair of femur fractures. Objectives: To evaluate serum NGAL as a predictor of AKI in the postoperative correction of femur fractures in the elderly. Methodology: 56 elderly patients undergoing surgical repair of femoral fracture were studied prospectively for 48 hours postoperatively. Blood samples were collected for analysis of NGAL after surgery, 4 and 24 hours later. Creatinine measurements collected 24 and 48 hours postoperatively. Accuracy of NGAL was analyzed for diagnosis of acute kidney injury. Results: 16 (28.1%) of patients developed AKI and had significantly higher values of serum NGAL. In 4hours the AUROC = 0799 (0663-0936, p <0.001). In 24 hours the AUROC = 0.805 (0665-0946, p <0001). Conclusion: The molecule of NGAL showed good accuracy for prediction of AKI within 24 hours when measured after 04 hours and 24 hours postoperatively / Mestre
2

Avaliação do comportamento mecânico de três diferentes tipos de osteossíntese em fratura de côndilo mandibular : análise por elementos finitos 3D /

Jesus, Giorge Pessoa de. January 2013 (has links)
Orientador: Luís Geraldo Vaz / Co-orientador: Mário Francisco Real Gabrielli / Banca: Pedro Yoshito Noritomi / Banca: Marcelo Ferraz Mesquita / Banca: Valfrido Antonio Pereira Filho / Banca: Marisa Aparecida Cabrini Gabrielli / Resumo: O uso de duas miniplacas retas é o método mais indicado na literatura, para se prevenir complicações no tratamento de fraturas de côndilo. Diferentes estudos evidenciam que a estabilidade da osteossíntese é relacionada com as tensões mecânicas que ocorrem na região do côndilo, geradas pelos músculos da mastigação. O objetivo neste estudo foi avaliar o comportamento mecânico de três métodos de osteossíntese, por meio de um modelo mandibular de elementos finitos (MEF), comparando a distribuição de tensões e o comportamento dos materiais nas fraturas subcondilares baixas. Simulou-se uma fratura transversa subcondilar baixa, no modelo mandibular e a adaptação dos materiais de osteossíntese para a fixação da fratura. Três métodos de fixação com placas de titânio foram testados: 1) duas placas retas; 2) uma placa lambda e 3) uma placa trapezoidal. Os resultados mostraram que os métodos de osteossíntese proporcionam uma boa rigidez ao sistema de fixação, com pouco deslocamento na linha de fratura. Apesar disto, com a intensidade da força aplicada, todos os modelos estariam sujeitos a falhas, pois apresentaram valores de tensão de von Mises muito elevados. Comparando o desempenho dos três modelos de placas testados, observou-se que, a placa lambda se comportou melhor, havendo uma distribuição das tensões de von Mises sobre o material de fixação e tensão máxima principal sobre o osso mais homogênea. / Abstract: The use of two straight plates is the most indicated in literature, to prevent the subcondilar fractures complications. Different studies have highlighted that the osteosynthesis stability is related to the mechanical stresses that occur in the region of the condyle, generated by the chewing muscles. This study evaluated the biomechanical behavior of three methods of fixation, through a mandibular finite element model (FEM), comparing the stress distribution and behavior of materials in low subcondilar fractures. A transverse fracture was simulated in the mandibular model and on adapting osteosynthesis materials for fracture fixation. Three methods of fixations using titanium plates were tested: two straight plates; one lambda plate and; one trapezoidal plate. The results showed that the method of osteosynthesis provides a good stiffness on the fixation system with little displacement at the fracture line. Nevertheless, by the intensity of the applied force, all models would be subject to failure, because they presented very high stress values. Comparing the performance of the three plate's models tested, it was observed better behaviors for the lambda plate, with a more homogeneous distribution of von Mises stresses on the osteosynthesis devices and maximum principal strain over the bone. / Doutor
3

Avaliação dos princípios de fotobiomodulação e bioatividade na otimização do reparo ósseo na fixação de fraturas em ratas ovariectomizadas /

Polo, Tárik Ocon Braga. January 2019 (has links)
Orientador: Leonardo Perez Faverani / Coorientador Roberta Okamoto / Banca: Letícia Helena Theodoro / Banca: Ana Paula Farnezi Bassi / Banca: Claudio Maldonado Pastori / Banca: Cassio Edvard Sverzut / Resumo: Este trabalho teve como objetivo avaliar o efeito da biomodulação e bioatividade no reparo ósseo de ratas ovariectomizadas submetidas à simulação de fraturas femurais. Sessenta e quatro ratas Wistar (Rattus novergicus), fêmeas, com 6 meses de idade, em que metade dos animais foram submetidos à ovariectomia bilateral (OVX) e a outra metade à cirurgia fictícia de ovariectomia (SHAM), e um período de 3 meses foi acompanhado para a verificar se a osteoporose estava presente. As ratas foram submetidas à simulação de fratura em ambos os fêmures e a fratura foi fixada com miniplaca e parafusos do sistema 1,5 mm. A metade das amostras tiveram miniplacas com texturização de superfície tratadas por oxidação com plasma eletrolítico (PEO), que ficou em contato com o "gap" reparacional e, a outra metade com miniplacas convencionais, com superfície (CONV). Estes grupos experimentais não foram submetidos à biomodulação (CO). Para o mesmo desenho experimental dos grupos, no ato operatório, após a fixação das fraturas, os demais grupos experimentais foram submetidos à fotobiomodulação por meio da irradiação do laser de baixa intensidade (LASER), durante 5 minutos. Aos 14 e 42 dias de pós-operatório, foi administrada calceína e alizarina, respectivamente, pela via intramuscular, na dose de 20 mg/kg de peso. A eutanásia de todos os animais foi realizada aos 60 dias de pós-operatório. Os grupos experimentais (SHAM/LASER/CONV; SHAM/CO/CONV; SHAM/LASER/PEO; SHAM/CO/PEO; OVX/LASER/CONV; OVX/CO/CONV... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effect of biomodulation and bioactivity on the bone repair of ovariectomized rats submitted to simulation of femoral fractures. 64 female adults Wistar rats (Rattus novergicus), which half of the animals was submitted to bilateral ovariectomy (OVX) and the other half to the dummy ovariectomy surgery (SHAM), and after 3-month the osteoporosis was induced. The rats were submitted to fracture simulation in both of the femurs and the fracture was fixed with miniplate and screws of the system 1.5 mm. Half of the samples had surface-textured miniplates treated by with plasma electrolytic oxidation (PEO), which was in contact with the repair gap, and the other half with conventional miniplates with surface (CONV). These experimental groups were not submitted to biomodulation (CO). For the same experimental design of the groups, after fracture fixation, the other experimental groups were submitted to photobiomodulation through low level laser (laser), for 5 minutes. At 14 and 42 postoperative days, calcein and alizarin, respectively, were administered intramuscularly at a dose of 20 mg / kg body weight. The animals were euthanized at 60 postoperative days. The experimental groups (SHAM/LASER/CONV, SHAM/CO/CONV, SHAM/LASER/PEO, SHAM/CO/PEO, OVX/LASER/CONV, OVX/CO/CONV, OVX/LASER/PEO), after euthanasia, had the regions of interest, initially scanned in computerized microtomography to evaluate the bone volume parameters [BV / TV] and bone qualit... (Complete abstract click electronic access below) / Doutor
4

Análise mecânica e fotoelástica de diferentes métodos de fixação mandibular na região do forame mentual

Itana Santos Fernandes January 2013 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2015-04-15T02:15:48Z No. of bitstreams: 1 Itana Santos Fernandes.pdf: 716606 bytes, checksum: bfc40cd2b0d01dcd144f4f7220ea267e (MD5) / Made available in DSpace on 2015-04-15T02:15:48Z (GMT). No. of bitstreams: 1 Itana Santos Fernandes.pdf: 716606 bytes, checksum: bfc40cd2b0d01dcd144f4f7220ea267e (MD5) Previous issue date: 2013 / O tratamento de fraturas de mandíbula na região de sínfise e parassínfise com uso de miniplacas e parafusos é especialmente problemático devido às forças de torção presentes nestas áreas. Os primeiros estudos a cerca do tema sugerem o uso de duas miniplacas do sistema 2,0mm fixadas acima e abaixo do forame mentual, com parafusos monocorticias, para neutralizar as cargas funcionais. Com a melhoria das ligas metálicas e o desenvolvimento de novos tipos de dispositivos de fixação, é possível sugerir que a utilização de uma única placa na zona de tensão da mandíbula seja suficiente para estabilizar a fratura durante o período de reparo ósseo. O objetivo deste trabalho foi revisar a literatura sobre as técnicas de fixação interna de fraturas de parassínfise mandibular ressaltando a possibilidade de alteração de técnica para a diminuição do número de placas para a estabilização das fraturas.
5

Avaliação da lipocalina associada à gelatinase de neutrófilos (NGAL) em idosos após osteossíntese de fêmur / Lipocalin assessment gelatinase associated with neutrophil (NGAL) in elderly patients after femoral osteosynthesis

Andrade Neto, José de Souza [UNESP] 22 May 2015 (has links) (PDF)
Made available in DSpace on 2015-10-06T13:02:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-05-22. Added 1 bitstream(s) on 2015-10-06T13:19:37Z : No. of bitstreams: 1 000847770.pdf: 603210 bytes, checksum: 9378a25e0f01dd3c1f600007a516b9f2 (MD5) / Introdução: A lesão renal aguda (LRA) ocorre em 23% dos pacientes hospitalizados. É responsável por alta morbimortalidade e, ainda assim, não há um marcador precoce e acurado de diagnóstico. Pacientes idosos estão em risco e frequentemente desenvolvem LRA no pós-operatório de grandes cirurgias ortopédicas. Objetivos: Avaliar o biomarcador NGAL plasmático como preditor precoce de LRA no período pós-operatório de fratura de fêmur em idosos. Método: 57 pacientes idosos submetidos à operação de correção de fratura de fêmur foram estudados prospectivamente após 48 horas do pós-operatório. Amostras de sangue foram coletadas para análise de NGAL logo ao término da cirurgia, no período de 4 e 24 horas depois. Amostras da creatinina foram coletadas na admissão hospitalar, 24 e 48 horas no pós-operatório. Foi analisada a acurácia da molécula de NGAL para diagnóstico de LRA. Resultados: Dezesseis (28%) pacientes desenvolveram LRA e apresentaram valores mais elevados de NGAL no plasma com diferença estatística significativa. A análise da área sob a curva Receiving Operator Characteristic demonstrou em 4 horas valor de 0.799 (0.663 a 0.936, p< 0,001); em 24 horas valor de 0.805(0.665 a 0.946, p<0,001). Conclusão: A molécula de NGAL apresentou uma boa acurácia para predição de LRA quando medido após 4 e 24 horas do período pós-operatório / Introduction: Introduction: Acute kidney injury is common in hospitalized patients undergoing surgical procedures. It is responsible for a high mortality and yet, there is no early and reliable diagnostic marker. Elderly patients are at risk and often undergo orthopedic procedures as surgical repair of femur fractures. Objectives: To evaluate serum NGAL as a predictor of AKI in the postoperative correction of femur fractures in the elderly. Methodology: 56 elderly patients undergoing surgical repair of femoral fracture were studied prospectively for 48 hours postoperatively. Blood samples were collected for analysis of NGAL after surgery, 4 and 24 hours later. Creatinine measurements collected 24 and 48 hours postoperatively. Accuracy of NGAL was analyzed for diagnosis of acute kidney injury. Results: 16 (28.1%) of patients developed AKI and had significantly higher values of serum NGAL. In 4hours the AUROC = 0799 (0663-0936, p <0.001). In 24 hours the AUROC = 0.805 (0665-0946, p <0001). Conclusion: The molecule of NGAL showed good accuracy for prediction of AKI within 24 hours when measured after 04 hours and 24 hours postoperatively
6

Osteossíntese minimamente invasiva com placa bloqueada nas fraturas de tíbia em cães /

Rosa-Ballaben, Nátalie Massaro. January 2014 (has links)
Orientador: Bruno Watanabe Minto / Banca: Cláudia Valéria Seullner Brandão / Banca: Paola Castro Moraes / Resumo: Avanços na compreensão da biologia óssea e das complicações das fraturas têm levado a modificações na abordagem da fixação interna das mesmas, sendo a osteossíntese minimamente invasiva com placa (MIPO) uma das mais recentes evoluções para o manejo biológico das fraturas. O objetivo do presente estudo foi avaliar o uso de placas bloqueadas aplicadas de forma minimante invasiva em fraturas de tíbia de cães. Foram utilizados 10 cães apresentando fraturas de tíbia, de idades e raças variadas. Os animais foram avaliados quanto a deambulação, intensidade do edema, exames radiográficos, e densitometria óptica nos períodos 0, 15, 30, 60, 90 e 120 dias de pós-operatório. Após 15 dias de pós-operatório 80% dos cães já utilizavam o membro ao caminhar e apresentavam formação de edema leve a ausente no membro operado. Após 30 dias de pós-operatório 100% dos cães já apoiavam o membro ao caminhar e não apresentavam formação de edema no membro. Todos os pacientes apresentaram sinais radiográficos e densitométricos de início de consolidação óssea após 15 dias de pós-operatório. O tratamento de fraturas de tíbia por meio da MIPO é uma alternativa eficaz, resultando em utilização precoce do membro e união clínica efetiva, e pode ser realizada sem uso de intensificadores de imagem / Abstract: Advances in the comprehension of the bone healing and complications of the treatment of the fractures have been changed some concepts. Less invasive procedures have been advocated. A minimally invasive plate osteosynthesis (MIPO) is one of the best ways to avoid over tissue damage. The aim of this study was to evaluate the use of MIPO in tibial fractures in dogs. Ten dogs presenting a tibial fracture were used. Deambulation, swelling intensity and radiographic changes were evaluated preoperatively, just after the procedure and at 15, 30, 60, 90 e 120 days postoperatively. Six of 10 (60%) dogs were able to walk at 15 days postoperatively with slight swelling and mild lameness. Two of 10 (20%) presented normal walking at the same period. At 30 days postoperatively all dogs were able to walk normally. Six of them were not lame and 9 did not present swelling. Bone healing could be followed by radiographic evaluation. All dog presented initial radiographic signs of bone healing after 15 days postoperatively. Two of 10 showed clinical union at this time. In five of 10 (50%) clinical union could be observed after 60 days. The treatment of tibial fractures by MIPO is an effective alternative resulting in early and effective clinical union and can be performed without the use of image intensifiers / Mestre
7

Avaliação do seio maxilar após fratura do complexo zigomático-maxilar tratado com fixação interna rígida em dois pontos : estudo radiográfico em humanos /

Kayatt, Fernando Esgaib. January 2002 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Resumo: O complexo zigomático maxilar é a segunda área da face mais atingida por injúrias, superada apenas pelos ossos nasais. É elemento essencial na configuração da face, uma vez que é a principal estrutura formadora do terço médio facial. É importante na biomecânica, está situado entre o víscero e o neurocrânio, desempenha papel fundamental na absorção e escoamento das forças de mastigação através dos pilares de reforço e sustentação. Nesse contesto encontra-se o seio maxilar cujas funções destacamse: diminuição do peso do crânio; auxiliar a ressonância da voz, a produção e a armazenagem do muco, a umidificação do ar inspirado, a manutenção do aquecimento da fossa nasal, servir como acessório do olfato, definir o contorno facial, entre outras. Avaliamos, através de radiografias PA de Waters, 40 pacientes, sendo 20 pacientes traumatizados nessa região, que foram submetidos à fixação interna rígida em dois pontos e 20 pacientes hígidos, comparando a projeção da imagem do contorno do seio maxilar. Estas avaliações foram realizadas em um período pós-operatório superior a 6 meses. Após análise dos resultados, concluímos que baseado nos achados radiográficos e nos valores de áreas dos seios maxilares, a fixação interna rígida em dois pontos mostrou-se eficaz no tratamento das fraturas não cominutivas do complexo zigomáticomaxilar. / Abstract: The ZMC is the second facial area most affected by injuries, only surpassed by nasal bones fractures. It's an essential element in facial configuration because it's the middle third facial main structure. It's important biomechanical being situated between the visceral and neurocranium, develop fundamental absorving and draining of the chewing forces job, across the sustaintation and strenghten pillars. Inside this complex the maxillary sinus and its functions are: to reduce head weight, to help voice ressonance, to produce and to store mucus, to umidificate the breathen air, to maintain the nasal fossa warm, olfative accessory and to define the facial contour and others. The research was performed through PA Waters radiography; 40 patients: 20 traumatizated patients in this region, submitted to the two points IRF and 20 health patients were evaluated, comparing the image projection of the maxillary sinus and observating the stability of this kind of fixation. These evaluations were made in post-operative periods, latter 6 months. After result analysis we concluded, based radiography evidence and measurement maxillary sinus area, the two points IRF are efficient on treatment of ZMC fractures not cominutive. / Mestre
8

Técnica experimental para inserção de parafuso no processo articular da coluna cervical inferior /

Azevedo, Gláucio Coelho de. January 2001 (has links)
Orientador: Hamilton da Rosa Pereira / Resumo: Este trabalho experimental propõe uma nova e eficiente técnica para in-trodução de parafuso no processo articular cervical, com menor risco. Utilizando um novo dispositivo e determinando o comprimento efetivo médio do parafuso. Foram usadas cinco colunas cervicais de esqueleto humano de C3 a C7, num total de 25 vértebras e 50 perfurações. Foram selecionados dois grupos de vértebras: um de C3 a C6, outro de C7. No primeiro grupo, o ponto inicial do parafuso situou-se a 2 mm. mediais e caudais do ponto central do processo articular, dirigindo-se a ponta do parafuso a 21,5º no sentido cranial. No outro grupo, o ponto inicial foi localizado a 2mm. da linha média vertical, logo abaixo da superfície articular superior, dirigindo-se a ponta do parafuso a 16,5º no sentido caudal. Em ambos os grupos, o parafuso foi desviado lateralmente a 42,5º. Concluímos que a nossa técnica é eficiente e segura porque: 1) utiliza um dispositivo que mede o ângulo de introdução do parafuso, bloqueando-o após a ultrapassagem da cortical anterior, introduzindo somente o comprimento ideal para cada processo articular, diminuindo o risco de lesão; 2) não causa lesão da artéria vertebral e da raiz nervosa; 3) apresenta baixa incidência de violação da superfície articular, 7,5% nas vértebras C3 a C6 e 0% nas C7; 4) apresenta um comprimento efetivo do parafuso de 10,7 mm. para ambos os grupos vertebrais oferecendo boa fixação óssea e boa margem de segurança, em relação às estruturas anatômicas importantes. / Abstract: This experimental paper presents a new and efficient technique to insert a screw in the cervical lateral mass with the less risk of damaging the vertebral artery, the nerve root and the articular facet. This procedure is carried out by using a new device which measures the screw insertion angle and lock the screw after it goes through the posterior cortical area. This paper also aims at determining the effective screw length to be used in this technique. Five human lower cervical spines from C3 to C7 - were used. Two holes were made in both sides of these 25 vertebrae. Therefore 50 holes were made. Two vertebrae groups were selected: C3-C6 and C7. In the C3-C6 group the start point of the screw was placed in a medial and caudal position 2mm. in relation to the central point of the articular prossece; the screw tip was directed to the half of the lateral vertebral line at a 21,5° angle in the cranial direction; for the C7 vertebrae the screw initial point was placed at a 2 mm. medial position in the vertical mean line just below the upper articular level; the screw tip was directed to the half of the lateral vertebral line at a 16,5° angle in the caudal direction. In both vertebral groups the screw was laterally deviated at a 42,5° angle. The conclusion is that this new technique is efficient and safe because: 1) it utilizes a new device to guide and measure the screw insertion and lock the screw after it goes through the posterior cortical area; the in-sertion is thus adequate for each specific lateral mass and decreases the risk of damage to the vertebral artery and to the nerve root; in fact it did not occur in both vertebral groups; 2) it presents a low rate of articular facet violation; 3) it presents a 10,7 mm. screw length which is effective for both vertebral groups; 4) therefore there occurs a good bone fixation and the important anatomic structures are preserved. / Doutor
9

Análise biomecanica de placa modificada de tplo em modelo experimental de falha óssea proximal em tíbias sintéticas caninas /

Sembenelli, Guilherme. January 2017 (has links)
Orientador: Luis Gustavo Gosuen Gonçalves Dias / Banca: Antonio Carlos Shimano / Banca: Bruno Watanabe Minto / Resumo: O objetivo do presente estudo foi desenvolver placa de TPLO bloqueada modificada e avaliar a eficácia da estabilização óssea proporcionada pelo implante desenvolvido comparativamente a outros dois métodos convencionais de fixação óssea (placa bloqueada e placa bloqueada associada a pino intramedular). Por meio de estudos biomecânicos, avaliaram-se as construções às forças de torção, flexão craniocaudal, flexão mediolateral e compressão axial. Foram utilizadas sessenta tíbias sintéticas dividas em três grupos. O Grupo 1 (placa TPLO modificada), o Grupo 2 (placa bloqueada) e o Grupo 3 (placa bloqueada associada a pino intramedular) foram qsubdivididos em quatro grupos de cinco tíbias. Os ensaios foram realizados até a falha da montagem (implantes e/ou tíbia) e os resultados obtidos comparados entre os grupos. As variáveis estudadas foram analisadas sob delineamento inteiramente casualizado no esquema fatorial 3 por 4 com 5 repetições para cada combinação do esquema fatorial. Os resultados foram submetidos à análise de variância e as médias comparadas entre si pelo teste de Tukey a 5% de probabilidade. No ensaio de compressão axial houve diferença significativa em relação a variável força máxima em que o Grupo 3 obteve maior média, não havendo diferença significativa entre os Grupos 1 e 2. Todas as montagens falharam devido à flexão da placa na região de falha no corpo de prova. No ensaio de flexão em três pontos craniocaudal houve diferença significativa em relação às três vari... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to develop modified TPLO locked plate and to evaluate the effectiveness of stabilization provided by the implant developed compared to two other conventional methods of stabilization (locked plate and plate-rod). Through biomechanical studies the constructions were evaluated to craniocaudal and mediolateral bending, axial compression and torsional forces. Sixty synthetic tibias were used divided into three groups. Group 1 (modified TPLO plate), Group 2 (locked plate) and Group 3 (plate-rod) were subdivided into four groups of five tibiae. The tests were perfomed until failure of the construction (implants / tibia) and the results compared between the groups. The variables studied were analyzed under a completely randomized design in the factorial scheme 3 by 4 with 5 replicates for each combination of the factorial scheme. The results were submitted to analysis of variance and the means compared to each other by the Tukey test at 5% probability. In the axial compression test there was a significant difference in relation to the variable maximum force in which Group 3 obtained higher mean, not having significant difference between Groups 1 and 2. All constructions failed due to plate bending in the gap region of the synthetic tibia. In the three-point craniocaudal flexion test there was a significant difference in relation to the three variables studied. In the variable force maximum G2> G3 = G1, in the variable deflection G3> G1 = G2 and in the varia... (Complete abstract click electronic access below) / Mestre
10

Plasma rico em plaquetas, medula óssea ou quitosana nas osteossínteses minimamente invasivas na tíbia de cães /

Filgueira, Fabrícia Geovânia Fernandes. January 2015 (has links)
Orientador: Bruno Watanabe Minto / Banca: Paola Castro Moraes / Banca: Sheila Canevese Rahal / Banca: Cláudia Valéria Seullner Brandão / Banca: Olícies da Cunha / Resumo: A osteossíntese minimamente invasiva com placa (MIPO) tem sido cada vez mais aceita para o tratamento de fraturas em pequenos animais, especialmente pela capacidade de preservação do hematoma inicial do foco fraturado. Outra forma de auxiliar o processo cicatricial ósseo é a utilização de biomateriais, tais como o plasma rico em plaquetas (PRP), aspirado de medula óssea (MO) e a quitosana (QUI). Objetivou-se, na presente pesquisa, avaliar a consolidação óssea obtida da MIPO e injeção percutânea de PRP, MO e QUI, no foco de fraturas tibiais de cães, por meio de exames clínicos, radiográficos e de densitometria óptica. Foram utilizados trinta cães apresentando fraturas da tíbia e atendidos na rotina cirúrgica do Hospital Veterinário da Faculdade de Ciências Agrárias e Veterinárias da UNESP, Jaboticabal. Os grupos foram formados de acordo com o biomaterial injetado sendo: grupo 1 (nada foi injetado), grupo 2 (MO), grupo 3 (PRP) e grupo 4 (QUI). Foram injetados 2 mL de cada biomaterial no foco da fratura, imediatamente após o procedimento de osteossíntese minimamente invasiva com placa bloqueada. Os animais foram avaliados quanto a intensidade de formação do edema (EDE), atividade deambulatória (DEAM), exames radiográficos e densitometria óptica no momento imediato após a cirurgia e 15, 30, 60, 90 e 120 dias pós-operatórios. Não houve diferença estatística significativa entre os grupos com relação ao EDE e DEAM. Setenta por cento dos animais operados nos diversos grupos apresentaram apoio do membro grau 4 ou 5 aos 15 dias de pós-operatório. Aos 30 dias, todos os animais apresentavam deambulação grau 5. Dentre os grupos (1, 2, 3 e 4) não se observou diferença estatística quanto ao uso do membro, entretanto o grupo 2 foi o que apresentou maior porcentagem (60%) de apoio aos 15 dias (grau 5). Houve diferença quanto ao momento da consolidação, ocorrendo mais cedo no grupo 2 (46,87 dias). Não houve... / Abstract: Minimally invasive plate osteosynthesis (MIPO) has become widely accepted for the treatment of fractures in small animals, especially because of the preservation of the initial hematoma and minimization of the soft tissues damage. Another way to improve bone healing is the use of biomaterials, such as platelet-rich plasma (PRP), aspirated bone marrow (MO) and chitosan (QUI). The aim of this study was to evaluate the bone healing after the association of MIPO and percutaneous injection of PRP, MO, and QUI in the treatment of tibial fractures in dogs. Clinical and radiographic examination and optical densitometry were used. Thirty dogs from the surgical routine of the Veterinary Teaching Hospital of the Faculty of Agricultural and Veterinarian Sciences (UNESP, Jaboticabal) presenting tibial fractures were used. The groups were formed according to injected biomaterial: group 1 (nothing was injected), group 2 (MO), group 3 (PRP) and group 4 (QUI). Two mililiters of each biomaterial was injected into the fracture site percutaneously just after the surgery. The dogs were evaluated for the intensity of edema formation (EDE), ambulatory activity (DEAM), radiographs and optical densitometry, immediately after surgery and 15, 30, 60, 90 and 120 days postoperatively. There was no significant difference between groups considering EDE and DEAM. Seventy percent of the animals presented member support grade 4 or 5 at 15 days postoperatively. After 30 days, all dogs presented without lameness. Among the groups, there was no statistical difference in the walk, however the group 2 showed the highest percentage (60%) of weight bearing at 15 days. There was a difference considering clinical union in the group 2 (46,87 days). There was no statistical difference in the mineral density of the bone callus formed between the groups and the moments assessed. The PRP, MO and QUI associated with MIPO help bone regeneration in the treatment of tibial fractures in ... / Doutor

Page generated in 0.1549 seconds