• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • Tagged with
  • 33
  • 33
  • 33
  • 17
  • 16
  • 14
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Tratamento das fraturas redutíveis e instáveis da extremidade distal do rádio - ensaio clínico randomizado comparativo dos métodos de fixação com placa volar bloqueada e com fixador externo / Treatment of reducible unstable fractures of the distal radius - randomized clinical study comparing the locked volar plate and external fixator methods.

Raduan Neto, Jorge [UNIFESP] January 2015 (has links) (PDF)
Submitted by Diogo Misoguti (diogo.misoguti@gmail.com) on 2016-06-24T15:00:05Z No. of bitstreams: 1 2015-12-doutorado-jorge-raduan-neto.pdf: 3009058 bytes, checksum: f417f06d1422ff0ff7fb5ef2c88c34c8 (MD5) / Approved for entry into archive by Diogo Misoguti (diogo.misoguti@gmail.com) on 2016-06-24T15:01:31Z (GMT) No. of bitstreams: 1 2015-12-doutorado-jorge-raduan-neto.pdf: 3009058 bytes, checksum: f417f06d1422ff0ff7fb5ef2c88c34c8 (MD5) / Made available in DSpace on 2016-06-24T15:01:31Z (GMT). No. of bitstreams: 1 2015-12-doutorado-jorge-raduan-neto.pdf: 3009058 bytes, checksum: f417f06d1422ff0ff7fb5ef2c88c34c8 (MD5) Previous issue date: 2015 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Introdução: No tratamento das fraturas instáveis da extremidade distal do rádio não há evidência conclusiva quanto à maior efetividade de um dos métodos de redução e fixação: incruenta com fixador externo (FE) ou aberta com placa volar bloqueada (PVB). Objetivo: O objetivo é determinar qual dos dois métodos é mais efetivo. Métodos: Oitenta pacientes foram incluídos neste ensaio clínico randomizado. O desfecho primário foi o questionário Disabilities of the Arm, Shoulder and Hand (DASH) e a mensuração da dor (EVA). A avaliação final deu-se com 12 meses de pós-operatório. Resultados: Na avaliação final não houve diferença entre os grupos nas avaliações do questionário DASH (3,71 para o grupo PVB e 2,72 para o grupo FE, p=0,58), e da dor pela EVA (0,84 para o grupo PVB e 0,53 para o grupo FE, p=0,39). O tratamento com PVB foi mais efetivo que aquele com FE na avaliação precoce com oito semanas para questionário DASH (21,82 para o grupo PVB e 39,88 para o grupo FE, p=0,0012). No grupo tratado com PVB, houve 11,7% de complicações e, no grupo tratado com fixador externo, 26,3%. Houve três falhas de tratamento no grupo tratado com PVB e nenhuma no outro grupo. Conclusão: Não se aferiram diferenças entre os grupos nas avaliações finais do questionário DASH e da dor pela EVA. Na avalição precoce com oito semanas, houve diferença favorável ao método de PVB. / Introduction: In the treatment of unstable fractures of the distal radius there is no conclusive evidence about the greater effectiveness of the reduction and fixation methods: bloodless external fixation (BEF) or open locked volar plate (LVP). The goal is to determine which of the two methods is most effective. Methods: Eighty patients were enrolled in this randomized clinical trial. The primary endpoint was the DASH questionnaire and measurement of pain (VAS). The final assessment was given at 12 months postoperatively. Results: In the final evaluation there was no difference between groups in assessments of the DASH questionnaire (3.71 for the LVP group and 2.72 for the BEF group, p = 0.58), and pain by VAS (0,84 to LVP group and 0.53 for the BEF group, p = 0.39). Treatment with LVP was more effective than one with BEF in early evaluation with eight weeks to DASH questionnaire (21.82 for the LVP group and 39.88 for the BEF group, p = 0.0012). In the group treated with LVP, there were 11.7% of complications and, in the group treated with external fixator, 26.3%. There were three treatment failures in the group treated with LVP and none in the other group. Conclusions: There were not assessed differences between groups in the final evaluations of the DASH questionnaire and the pain by VAS. In the early eight week assessment, there was positive difference to the LVP method. / FAPESP: 2012/00806-2
12

Plasma rico em plaquetas, medula óssea ou quitosana nas osteossínteses minimamente invasivas na tíbia de cães

Filgueira, Fabrícia Geovânia Fernandes [UNESP] 17 June 2015 (has links) (PDF)
Made available in DSpace on 2015-10-06T13:03:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-06-17. Added 1 bitstream(s) on 2015-10-06T13:19:01Z : No. of bitstreams: 1 000848389_20160717.pdf: 645088 bytes, checksum: 7efbb789012e4c9a7edbfe4aafab7d47 (MD5) Bitstreams deleted on 2016-07-25T13:17:35Z: 000848389_20160717.pdf,. Added 1 bitstream(s) on 2016-07-25T13:18:44Z : No. of bitstreams: 1 000848389.pdf: 1956327 bytes, checksum: 7b8fc0ca64b60062269d66c525ec0fca (MD5) / A osteossíntese minimamente invasiva com placa (MIPO) tem sido cada vez mais aceita para o tratamento de fraturas em pequenos animais, especialmente pela capacidade de preservação do hematoma inicial do foco fraturado. Outra forma de auxiliar o processo cicatricial ósseo é a utilização de biomateriais, tais como o plasma rico em plaquetas (PRP), aspirado de medula óssea (MO) e a quitosana (QUI). Objetivou-se, na presente pesquisa, avaliar a consolidação óssea obtida da MIPO e injeção percutânea de PRP, MO e QUI, no foco de fraturas tibiais de cães, por meio de exames clínicos, radiográficos e de densitometria óptica. Foram utilizados trinta cães apresentando fraturas da tíbia e atendidos na rotina cirúrgica do Hospital Veterinário da Faculdade de Ciências Agrárias e Veterinárias da UNESP, Jaboticabal. Os grupos foram formados de acordo com o biomaterial injetado sendo: grupo 1 (nada foi injetado), grupo 2 (MO), grupo 3 (PRP) e grupo 4 (QUI). Foram injetados 2 mL de cada biomaterial no foco da fratura, imediatamente após o procedimento de osteossíntese minimamente invasiva com placa bloqueada. Os animais foram avaliados quanto a intensidade de formação do edema (EDE), atividade deambulatória (DEAM), exames radiográficos e densitometria óptica no momento imediato após a cirurgia e 15, 30, 60, 90 e 120 dias pós-operatórios. Não houve diferença estatística significativa entre os grupos com relação ao EDE e DEAM. Setenta por cento dos animais operados nos diversos grupos apresentaram apoio do membro grau 4 ou 5 aos 15 dias de pós-operatório. Aos 30 dias, todos os animais apresentavam deambulação grau 5. Dentre os grupos (1, 2, 3 e 4) não se observou diferença estatística quanto ao uso do membro, entretanto o grupo 2 foi o que apresentou maior porcentagem (60%) de apoio aos 15 dias (grau 5). Houve diferença quanto ao momento da consolidação, ocorrendo mais cedo no grupo 2 (46,87 dias). Não houve... / Minimally invasive plate osteosynthesis (MIPO) has become widely accepted for the treatment of fractures in small animals, especially because of the preservation of the initial hematoma and minimization of the soft tissues damage. Another way to improve bone healing is the use of biomaterials, such as platelet-rich plasma (PRP), aspirated bone marrow (MO) and chitosan (QUI). The aim of this study was to evaluate the bone healing after the association of MIPO and percutaneous injection of PRP, MO, and QUI in the treatment of tibial fractures in dogs. Clinical and radiographic examination and optical densitometry were used. Thirty dogs from the surgical routine of the Veterinary Teaching Hospital of the Faculty of Agricultural and Veterinarian Sciences (UNESP, Jaboticabal) presenting tibial fractures were used. The groups were formed according to injected biomaterial: group 1 (nothing was injected), group 2 (MO), group 3 (PRP) and group 4 (QUI). Two mililiters of each biomaterial was injected into the fracture site percutaneously just after the surgery. The dogs were evaluated for the intensity of edema formation (EDE), ambulatory activity (DEAM), radiographs and optical densitometry, immediately after surgery and 15, 30, 60, 90 and 120 days postoperatively. There was no significant difference between groups considering EDE and DEAM. Seventy percent of the animals presented member support grade 4 or 5 at 15 days postoperatively. After 30 days, all dogs presented without lameness. Among the groups, there was no statistical difference in the walk, however the group 2 showed the highest percentage (60%) of weight bearing at 15 days. There was a difference considering clinical union in the group 2 (46,87 days). There was no statistical difference in the mineral density of the bone callus formed between the groups and the moments assessed. The PRP, MO and QUI associated with MIPO help bone regeneration in the treatment of tibial fractures in ...
13

Estudo mecânico comparativo da estabilização de fratura ilíaca com dois tipos de implantes (parafusos com placa de compressão dinâmica e parafusos associados ao polimetilmetacrilato) em hemipelves caninas sintéticas

Prada, Tiago Carmagnani [UNESP] 24 February 2015 (has links) (PDF)
Made available in DSpace on 2015-08-20T17:09:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-24. Added 1 bitstream(s) on 2015-08-20T17:26:26Z : No. of bitstreams: 1 000835505.pdf: 765609 bytes, checksum: c2d6333de2a901979de6850158d1e391 (MD5) / As fraturas da pelve correspondem a 20-30% das fraturas encontradas nos cães e, geralmente são ocasionadas por trauma de grande intensidade na região caudal do animal. Nos casos onde há fraturas completas, principalmente com desvio ósseo, o tratamento cirúrgico é recomendado. O estudo mecânico das técnicas cirúrgicas que podemos utilizar é de extrema importância para avaliação da melhor maneira de tratamento destas lesões. O objetivo deste estudo foi comparar, do ponto de vista biomecânico, a fixação das fraturas do ílio utilizando placa de compressão dinâmica ou parafusos associados ao polimetilmetacrilato através de um teste estático. Foram utilizadas 16 pelves caninas de origem sintética, nas quais uma osteotomia transversa foi realizada no corpo do ílio. As fixações foram divididas em dois grupos: fixação com placa de compressão dinâmica e parafusos ou parafusos associados ao polimetilmetacrilato. Posteriormente à fixação com os implantes foi aplicada uma carga no acetábulo de cada corpo de prova até a falha. A estabilização com o polimetilmetacrilato mostrou ser mais resistente, pois resistiu a uma maior quantidade de carga em relação à placa de compressão dinâmica em todos os corpos de prova / Pelvic fractures correspond 20 to 30 % of the fractures observed in dogs. They are usually caused by trauma in the posterior region. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques that we can use is very important to evaluate the best way to treat these fractures. The aim of this study was to compare, biomechanically, the use of a dynamic compression plate or screws and polymethylmethacrylate to stabilize a ilial body fracture using a static test. Sixteen canine synthetic pelvis (test specimens) with a transverse osteotomy of the ilial body were used. After the fixation with the implants a load to the acetabulum was applied until fail. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate, resisting to a greater amount of charge in all test specimens
14

Osteossíntese de tíbia com uso de fixador esquelético externo conectado ao pino intramedular "tie-in" em cães /

Dias, Luis Gustavo Gosuen Gonçalves. January 2006 (has links)
Orientador: João Guilherme Padilha Filho / Banca: Júlio Carlos Canola / Banca: Jorge Luiz Oliveira Costa / Resumo: A incidência de fratura de tíbia em cães representa 21% das que ocorrem nos ossos longos. Vários métodos são utilizados nas osteossínteses deste osso, tais como: pinos intramedulares; fixadores esqueléticos externos; placas ósseas e; associações entre eles. O método usado foi uma modificação da configuração denominada "tie-in", na qual um PIM é conectado externamente a pinos de Schanz ou parafusos de aço inoxidável fixados com metil-metacrilato. O PIM é introduzido através de um orifício confeccionado na face medial da tíbia, próximo à crista tibia!. A configuração foi utilizada em 21 cães com fratura de tíbia atendidos no Hospital Veterinário do Câmpus da UNESP de Jaboticabal-SP. Os animais foram avaliados clínica e" radiograficamente, no período pré e pós-operatório imediato e a cada 30 dias, até completar quatro meses. Os animais recuperaram, clinicamente, a função do membro no período médio de 11 dias após a cirurgia. Nove animais tiveram a configuração dinamizada, por meio da desconexão do PIM; remoção do PIM ou dos implantes de fixação e retirada dos implantes de fixação e manutenção do PIM. Radiograficamente verificou-se consolidação óssea em média de 76 dias de pós operatório, e apenas um animal apresentou não-união. A configuração "tie-in" mostrou se eficaz como método de osteossíntese em fraturas tibiais de cães. / Abstract: The incidence of tibial fractures in dogs assumes 21 % of ali fractures that occur in long bones. Several methods are used in the osteosynthesis, of these fractures like external skeletal fixator, bone plates and associated techniques. The aim of this study is to describe the method and perform a radiographic and clinical evaluation of a group of 21 dogs with tibial fractures from the veterinary teaching hospital of the UNESP SÃO PAULO STATE UNIVERSITY- CAMPUS OF JABOTICABAL. The used method was a modification of the termed "tie-in" configuration, in that an IMP was connected externally with Schanz pins or stainless steel screws fixed together with methylmethacrylat. The pin was applied through hole on the medial tibia near the tibial crest. Clinical and radiographic evaluations were performed in pre-and post-operatory period and at 30, 60, 90 and 120 days. Animais recovered the function of the affected limb in a mean period of 11 days afier the surgery. Nine dogs underwent dynamization through: a) IMP disconnection, b) IMP or, c) fixation pins takeout and d) fixation pins takeout and maintenance of the IMP. Radiographicaly, the fracture union occurred in 20 dogs, in a mean period of 76 days; non-union was observed in only one dog. T~erefore, the "tie-in" modificated frame configuration showed efficacy as a method of osteosynthesis in tibial fractures of dogs. / Mestre
15

Estudo mecânico comparativo da estabilização de fratura ilíaca com dois tipos de implantes (parafusos com placa de compressão dinâmica e parafusos associados ao polimetilmetacrilato) em hemipelves caninas sintéticas /

Prada, Tiago Carmagnani. January 2015 (has links)
Orientador: Bruno Watanabe Minto / Banca: Luis Gustavo Gosuen Gonçalves Dias / Banca: Sheila Canevese Rahal / Resumo: As fraturas da pelve correspondem a 20-30% das fraturas encontradas nos cães e, geralmente são ocasionadas por trauma de grande intensidade na região caudal do animal. Nos casos onde há fraturas completas, principalmente com desvio ósseo, o tratamento cirúrgico é recomendado. O estudo mecânico das técnicas cirúrgicas que podemos utilizar é de extrema importância para avaliação da melhor maneira de tratamento destas lesões. O objetivo deste estudo foi comparar, do ponto de vista biomecânico, a fixação das fraturas do ílio utilizando placa de compressão dinâmica ou parafusos associados ao polimetilmetacrilato através de um teste estático. Foram utilizadas 16 pelves caninas de origem sintética, nas quais uma osteotomia transversa foi realizada no corpo do ílio. As fixações foram divididas em dois grupos: fixação com placa de compressão dinâmica e parafusos ou parafusos associados ao polimetilmetacrilato. Posteriormente à fixação com os implantes foi aplicada uma carga no acetábulo de cada corpo de prova até a falha. A estabilização com o polimetilmetacrilato mostrou ser mais resistente, pois resistiu a uma maior quantidade de carga em relação à placa de compressão dinâmica em todos os corpos de prova / Abstract: Pelvic fractures correspond 20 to 30 % of the fractures observed in dogs. They are usually caused by trauma in the posterior region. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques that we can use is very important to evaluate the best way to treat these fractures. The aim of this study was to compare, biomechanically, the use of a dynamic compression plate or screws and polymethylmethacrylate to stabilize a ilial body fracture using a static test. Sixteen canine synthetic pelvis (test specimens) with a transverse osteotomy of the ilial body were used. After the fixation with the implants a load to the acetabulum was applied until fail. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate, resisting to a greater amount of charge in all test specimens / Mestre
16

Estudo comparativo do Titânio versus Polímero vegetal para fixação interna rígida de fraturas orbitárias de coelhos /

Nunes, Elifas Levy. January 2006 (has links)
Orientador: Silvana Artioli Schellini / Banca: Claudia Helena Pellizon / Banca: Jair Cortez Montovani / Banca: Antonio Carlos Neder / Banca: Suzana Matayoshi / Resumo: Nas últimas décadas, os materiais utilizados para reparações ósseas de estruturas faciais tiveram um aprimoramento que muito facilitou a fixação interna rígida. Entretanto, este campo permanece aberto para as pesquisas até os dias atuais, uma vez que não se tem ainda o material ideal para este fim. Objetivo: avaliar a reparação de fraturas da parede orbitária usando a fixação interna rígida com miniplacas de titânio e de polímero vegetal comparando-as. Material e método: foi realizado um estudo experimental, prospectivo, na Faculdade de Medicina de Botucatu, no qual foram utilizados 45 coelhos albinos, submetidos a fratura do assoalho da órbita e divididos em três grupos especiais... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the last few decades, the advances in material used for repairing facil bone fractures have greatly improved internal rigid fixing. However research in this area remains open as there still no ideal material. Objective: to evaluate the repair of orbital wall fractures with internal rigid fixings comparing mini titanium and reabsorbable vegetal polymer plates... (Complete abstract, click eletronic address below) / Doutor
17

Tratamento cirúrgico intrabucal das fraturas de ângulo mandibular com uma miniplaca de titânio : estudo clínico e radiográfico /

Érnica, Natasha Magro. January 2002 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Cássio Edvard Sverzut / Banca: Wilson Roberto Poi / Resumo: O objetivo deste estudo foi avaliar, clínica e radiograficamente, pacientes com fraturas de ângulo mandibular tratadas por meio de redução cirúrgica e fixação com uma miniplaca de titânio de 2,0 mm de espessura, associada a parafusos monocorticais. Foram avaliados retrospectivamente 21 pacientes, com 22 fraturas fraturas de ângulo mandibular, tratados pela equipe de Cirurgia e Traumatologia Buco-Maxilo- Facial da Faculdade de Odontologia de Araçatuba - UNESP, na Santa Casa de Misericórdia de Araçatuba e Santa Casa de Misericórdia de Birigüi, Estado de São Paulo, no período de julho de 1999 a fevereiro de 2002. Todas as fraturas de ângulo mandibular avaliadas foram fixadas utilizando uma miniplaca de 2,0 mm de espessura, com parafusos monocorticais, disposta ao longo da linha oblíqua mandibular, sem utilização de fixação intermaxilar no pós-operatório. O tempo de proservação variou de 6 a 44 meses, com média de 15 meses e 1 dia. Foi observada, para essas fraturas, incidência de 14,3% de complicações pós-operatórias, sendo 4,8% infecção, 4,8% má-oclusão e 4,8% distúrbios sensoriais - hiperestesia no local de retenção da miniplaca. Dentre as complicações, a única que exigiu nova intervenção cirúrgica sob anestesia local foi a infecção pós-operatória. Assim, pode-se concluir que o método empregado foi clinicamente adequado para o tratamento de fraturas simples de ângulo mandibular, a presença de apenas uma miniplaca não interferiu no índice de complicações pós-operatórias, e o método evitou a fixação intermaxilar pós- operatória. / Abstract: The aim of this study was to evaluate clinical and radiographic, mandibular angle fractures treated by open reduction and one single 2.0 mm titanium miniplate fixation associated with monocortical screws. The author retrospectively evaluated 21 patients, with 22 mandibular angle fractures, operated by Oral and Maxillofacial Surgery Division from the Dental School of Araçatuba, UNESP, Brazil, during the period from July 1999 to February 2002. All mandibular angle fractures studied were treated by open reduction and internal fixation with one single 2.0 mm miniplate, positioned along the mandible oblique line, without post-operative intermaxilar fixation. Follow-up ranged from 6 to 44 months, with a mean of 15 months and 1 day. Complications occurred in 3 patients (14,3%). One patient (4,8%) presented post-operative infection, one (4,8%) malocclusion, and one (4,8%) sensory disturbance - hyperesthesia in the region of the retained miniplate. The only case requiring a further surgical intervention under general anesthesia was the infection case. Thus, results allowed to conclude that the fixation method was suitable for treatment of simple mandibular angle fractures, the presence of only one single miniplate did not interfere on the post-operative complication rate, and the method avoided post-operative intermaxilar fixation. / Mestre
18

Caracterização físico-química, morfológica, análise mecânica e de elementos finitos 3D, de diferentes placas e parafusos metálicos e técnicas de fixação interna, empregadas em fraturas de ângulo mandibular /

Guastaldi, Fernando Pozzi Semeghini. January 2013 (has links)
Orientador: Eduardo Hochuli Vieira / Banca: Sérgio Alexandre Gehrke / Banca: Eduardo Sanches Gonçales / Banca: Idelmo Rangel Garcia Junior / Banca: Luis Geraldo Vaz / Resumo: Proposição: Realizar uma caracterização físico-química, morfológica e comparar o comportamento mecânico de uma liga experimental de Ti-Mo, ao sistema de fixação análogo à base de Ti, em fraturas de ângulo mandibular, favoráveis ao deslocamento. Adicionalmente, análises de elementos finitos 3D foram realizadas para avaliar o padrão de distribuição de tensões nas placas e nos parafusos. Material e Método: Vinte e oito réplicas de mandίbulas de poliuretano foram usadas e uniformemente seccionadas na região do ângulo mandibular esquerdo. Estas foram divididas em 4 grupos considerando o material das placas e as técnicas de fixação interna: grupo Eng 1P, uma placa (zona de tensão da mandίbula) e 4 parafusos de 6 mm de comprimento; grupo Eng 2P, duas placas (uma na zona de tensão da mandίbula e a outra na zona de compressão), a primeira fixada com 4 parafusos de 6 mm de comprimento e a segunda com 4 parafusos de 12 mm de comprimento, sendo todo o material de fixação do sistema 2.0-mm. Os mesmos grupos foram criados para a liga Ti-15Mo. Cada grupo foi submetido a uma carga vertical linear no primeiro molar. As médias e os desvios-padrão foram comparados para avaliação estatίstica (ANOVA; p < .05). Adicionalmente, foi construído um modelo de elementos finitos 3D considerando as mesmas variáveis para avaliar as tensões equivalentes de von Mises (σvM) nas placas e nos parafusos. Resultados: Diferença estatisticamente significativa (p < .05) foi encontrada quando foi realizada a comparação entre ambas as técnicas de fixação (1 e 2 placas), independentemente do material das placas (cpTi and Ti-15Mo). Quando considerado os valores das tensões equivalentes de von Mises (σvM) para... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose: Perform a physico-chemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures, favorable to displacement. Additionally, finite element analysis was performed to assess the stress distribution in the plates and screws. Material and Method: Twenty eight polyurethane mandible replicas were used and uniformly sectioned on the left mandibular angle. These were divided into 4 groups considering the material of the plates and the internal fixation techniques: group Eng 1P, one 2.0-mm plate (tension zone of the mandible) and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates (one in the tension zone of the mandible and the other in the compression zone), the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the titanium alloy (Ti-15Mo). Each group was subjected to linear vertical loading at the first molar. Means and standard deviations were compared with respect to statistical significance (ANOVA; p < .05). Additionally, an three-dimensional finite element model reproducing the characteristics of the specimens used in the mechanical tests were created to evaluate the von Mises equivalent stress (σvM) in the plates and screws. Results: Statistically significant difference (p < .05) was found when the comparison between both internal fixation techniques (1 and 2 plates) was performed, regardless the materials of the plates (cpTi and Ti-15Mo). When considering the von Mises equivalent stress (σvM) values for the comparison between both groups (Eng and Ti-15Mo) with 1 plate, an decrease of 10.5% in the plate and an decrease of 29.0% in the screws... (Complete abstract click electronic access below) / Doutor
19

Comparação biomecânica e da redução óssea do Clamp and Rod Internal Fixation e placa de reconstrução bloqueada em fraturas de acetábulo / Comparação biomecânica e da redução óssea de Clamp and Rod Internal Fixation (CRIF) e placa de reconstrução bloqueada em fraturas de acetábulo

Bregadioli, Thales 19 April 2017 (has links)
Este estudo objetivou comparar, biomecanicamente, por meio dos ensaios de flexão destrutível e ciclagem, bem como a qualidade da redução óssea, após avaliação do molde da superfície articular de osteotomias centrais do acetábulo de cão fixadas com Clamp and Rod Internal Fixation (CRIF) 2,7 mm ou placa de reconstrução bloqueada 2,7 mm. Os implantes foram divididos em dois grupos, denominados grupo CRIF (GC) e grupo Placa (GP). Foram utilizadas nove pelves de cadáveres de cão com peso corporal entre 15 e 35 kg, posteriormente as pelves foram subdivididas em 18 hemipelves e distribuídas aleatoriamente para testar os dois implantes, um contralateral ao outro em uma mesma pelve. Para realização dos testes, foi simulado uma fratura central no acetábulo, por meio de osteotomia linear, realizada com auxílio de serra oscilatória e em seguida, fixadas segundo os padrões AO/SIF, sendo utilizados três parafusos craniais e dois caudais a osteotomia. Após comparação biomecânica de resistência máxima à flexão o GP (22,38&#177;8,44 N.m) demonstrou superioridade estatística em relação ao GC (15,60&#177;5,76 N.m), (p=0,02408). Na comparação do molde da superfície articular após 30 ciclos o GP (0,27 &#177; 0,24mm) demonstrou valores menores para lacuna da linha articular que o GC (0,49 &#177; 0,29mm), sendo o GP estatisticamente superior, (p=0,04784). Em conclusão, a aplicação da placa de reconstrução bloqueada é simples e deve ser considerada para redução de fraturas do acetábulo que necessitem de reconstrução anatômica. / The aim of this study was to compare the accuracy of reduction and biomechanical characteristics of acetabular osteotomies repaired with 2.7-mm Clamp and Rod Internal Fixation (CRIF) constructs or 2.7-mm locking reconstruction plates in cyclic and load to failure flexion tests. Nine dog cadavers with body weight between 15 and 35 kg were included in this study. All 18 hemipelves were randomly assigned into two groups named after the implants tested, group CRIF (GC) and group Plate (GP). All pelves were used to test both groups with each hemipelvis belonging to a different implant group. Acetabular osteotomies were created with an oscillatory saw and then fixed according to the AO/ASIF standards, using either 5-hole, 2.7-mm locking reconstruction plates with three locked screws cranial and two caudal to the osteotomy line, or CRIF constructs with 5 clamps, three located cranial and two caudal to the osteotomy line. Load to failure at GP (22.38 &#177; 8.44N.m) was significantly higher than GC (15.60 &#177; 5.76N.m), (p = 0.02408). Imprinted cast of acetabular reduction gap after 30 cycles was statistically smaller at GP (0.27 &#177; 0.24mm) than GC (0.49 &#177; 0.29mm) (p = 0.04784). We concluded that the appliance of locking reconstruction plates is simple and should be considered for acetabular fractures, that require perfect anatomical reconstruction.
20

Estudo comparativo entre as osteossínteses de tornozelo com implantes convencionais e bioabsorvíveis / Comparative study of osteosynthesis of ankle with conventional and bioabsorbable implants

Gaiarsa, Guilherme Pelosini 06 March 2013 (has links)
O padrão ouro no tratamento cirúrgico das fraturas de tornozelo são as sínteses metálicas, sejam de titânio ou aço. Os implantes bioabsorvíveis foram desenvolvidos para evitar o efeito do stress shielding, ou escudo de carga, e a retirada de material de síntese. O uso de materiais absorvíveis é bem documentado, e com bons resultados em grande número de fraturas craniofaciais. O objetivo deste estudo foi comparar os resultados funcionais de fraturas de tornozelo tratadas com placas metálicas e absorvíveis. Os pacientes foram randomizados e seguidos de forma prospectiva em dois grupos, metálico e absorvível. No período pós operatório imediato os pacientes foram imobilizados com tala gessada por uma semana, substituída por órtese removível por mais 4 semanas. Carga parcial foi autorizada com 3 semanas, e carga total com 6 semanas. Dezenove pacientes foram seguidos por nove meses, e avaliados radiográfica e funcionalmente aos 6 e 9 meses. Todos consolidaram entre 8 e 12 semanas. A recuperação funcional foi similar nos dois grupos. Aos 6 meses, três pacientes no grupo metálico queixaram-se de problemas locais, e tiveram seus implantes removidos. Um paciente do grupo absorvível teve uma deiscência da sutura, tratado com boa evolução. Aos 9 meses foi aplicado o escore da AOFAS para todos os pacientes. Os resultados funcionais foram semelhantes nos dois grupos, após a retirada de implante de três pacientes no grupo metálico. Os implantes absorvíveis permitiram resultados clínicos e funcionais semelhantes aos metálicos em fraturas de tornozelo / The current gold standard fixation system for surgical ankle fractures are the metallic implants, steel or titanium made. Resorbable implants have been developed to avoid stress shielding and a new surgery for implant removal, common with metal implants. Use of resorbable implants is well documented in the literature for a range of craniofacial fractures, with good results. The purpose of this study was to compare the outcome of ankle fractures using biodegradable and metal plates. Patients were randomly and prospectively treated with resorbable or metal fixation system. Post-operatively, the ankle was immobilized with a plaster cast for 1 week, removable cast for other 4 weeks. Half and full weight bearing were allowed at weeks 3 and 6. nineteen patients were followed for 9 months. Functional recovery was similar in both groups at 6 and 9 months, three patients in metal group complained implant-related problems, and had their implants removed, and one in resorbable had an acute dehiscence, solved with surgical debridement and closure. At 6 and 9 months, the AOFAS score was applied for all patients. The functional results were similar in both groups. Implant removal was necessary in three patients from the metallic group. The resorbable plate provided qualitatively similar fracture healing results as the metal plate

Page generated in 0.1497 seconds