• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do seio maxilar após fratura do complexo zigomático-maxilar tratado com fixação interna rígida em dois pontos : estudo radiográfico em humanos /

Kayatt, Fernando Esgaib. January 2002 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Resumo: O complexo zigomático maxilar é a segunda área da face mais atingida por injúrias, superada apenas pelos ossos nasais. É elemento essencial na configuração da face, uma vez que é a principal estrutura formadora do terço médio facial. É importante na biomecânica, está situado entre o víscero e o neurocrânio, desempenha papel fundamental na absorção e escoamento das forças de mastigação através dos pilares de reforço e sustentação. Nesse contesto encontra-se o seio maxilar cujas funções destacamse: diminuição do peso do crânio; auxiliar a ressonância da voz, a produção e a armazenagem do muco, a umidificação do ar inspirado, a manutenção do aquecimento da fossa nasal, servir como acessório do olfato, definir o contorno facial, entre outras. Avaliamos, através de radiografias PA de Waters, 40 pacientes, sendo 20 pacientes traumatizados nessa região, que foram submetidos à fixação interna rígida em dois pontos e 20 pacientes hígidos, comparando a projeção da imagem do contorno do seio maxilar. Estas avaliações foram realizadas em um período pós-operatório superior a 6 meses. Após análise dos resultados, concluímos que baseado nos achados radiográficos e nos valores de áreas dos seios maxilares, a fixação interna rígida em dois pontos mostrou-se eficaz no tratamento das fraturas não cominutivas do complexo zigomáticomaxilar. / Abstract: The ZMC is the second facial area most affected by injuries, only surpassed by nasal bones fractures. It's an essential element in facial configuration because it's the middle third facial main structure. It's important biomechanical being situated between the visceral and neurocranium, develop fundamental absorving and draining of the chewing forces job, across the sustaintation and strenghten pillars. Inside this complex the maxillary sinus and its functions are: to reduce head weight, to help voice ressonance, to produce and to store mucus, to umidificate the breathen air, to maintain the nasal fossa warm, olfative accessory and to define the facial contour and others. The research was performed through PA Waters radiography; 40 patients: 20 traumatizated patients in this region, submitted to the two points IRF and 20 health patients were evaluated, comparing the image projection of the maxillary sinus and observating the stability of this kind of fixation. These evaluations were made in post-operative periods, latter 6 months. After result analysis we concluded, based radiography evidence and measurement maxillary sinus area, the two points IRF are efficient on treatment of ZMC fractures not cominutive. / Mestre
2

Estudo comparativo dos resultados de enxertos de vidro bioativo e osso autógeno, associados ou não ao plasma rico em plaquetas, em seio maxilar de coelho : análise fractal, densitométrica e histomorfométrica /

Suedam, Ivy Kiemle Trindade. January 2007 (has links)
Resumo: O objetivo do presente estudo foi avaliar o efeito da associação de osso autógeno (OA) e de vidro bioativo (VB) ao plasma rico em plaquetas (PRP) como substitutos ósseos no interior de seios maxilares (SM) de coelhos, por meio de análise radiográfica da densidade óssea e da dimensão fractal e análise histomorfométrica. Adicionalmente, pretendeu-se validar os métodos da densidade óssea e dimensão fractal como indicadores da neoformação óssea. Para tanto, 20 coelhos divididos em dois grupos (G1 e G2) foram submetidos à cirurgia de levantamento de SM. No G1, 10 SM esquerdos foram enxertados com OA e 10 SM direitos com VB. No G2, 10 SM esquerdos foram enxertados com uma combinação de OA+PRP e 10 SM direitos com VB+PRP. Após 90 dias, os animais foram sacrificados e radiografias padronizadas dos SMs foram obtidas. Os valores médios (desvio padrão) da densidade óssea, expressa em milímetros equivalentes de alumínio, para os tratamentos OA, VB, OA+PRP e VB+PRP foram, respectivamente, 1,79(0,316), 2,04(0,398), 1,61(0,285) e 1,53(0,309), sendo que diferenças estatisticamente significantes (p<0,05) foram encontradas entre os valores de VB e OA, e, VB+PRP e VB. Na dimensão fractal, os valores encontrados, que podem variar de 1 a 2, foram 1,48(0,040), 1,35(0,084), 1,44(0,043) e 1,44(0,066), respectivamente. Diferenças significantes (p<0,05) foram encontradas entre os valores de VB e OA, e, OA+PRP e VB. Na histometria, expressa em porcentagem de preenchimento ósseo, os valores obtidos foram 63,30l8,609, 52,65(10,415), 55,25(7,018) e 51,07(10,255), respectivamente. Não foram encontradas diferenças estatísticas entre os tratamentos. Não houve correlação estatisticamente significante entre as variáveis densidade óssea, dimensão fractal e porcentagem de osso. Na análise histológica dos SM tratados com OA observou-se tecido ósseo neoformado, ricamente... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of the present study was to evaluate the use of autogenous bone (AB) and bioactive glass (BG) and the association of these materials with platelet-rich plasma (PRP), as bone substitutes in the rabbit maxillary sinus (MS) by means of radiographical bone density and fractal dimension and by histomorphometrical analysis. In addition, the study aimed at validating the two radiographic methods as indicators of bone formation. Twenty rabbits divided into two groups (G1 and G2) were submitted to sinus lift surgery. In G1, 10 left MS were grafted with AB and 10 right MS were grafted with BG. In G2, 10 left MS were grafted with AB+PRP and 10 right MS were grafted with VB+PRP. Ninety days after, the animals were sacrificed and standardized radiographs were taken. Mean values (standard deviation) of bone density, expressed as aluminium equivalent milimeters, in MS grafted with OA, VB, OA+PRP and VB+PRP were 1,79l0,316, 2,04l0,398, 1,61l0,285 and 1,53l0,309, respectively. Statistically significant differences (p <0,05) were observed in bone density between BG and AB, and between BG+PRP and BG. Mean values of fractal dimension, which can vary from 1 to 2, were 1,48l0,040, 1,35l0,084, 1,44l0,043 and 1,44l0,066, respectively. Significant differences were observed between BG and AB and AB+PRP and BG. Mean values of percentage of bone inside MS, assessed by histometrical analysis were, respectively, 63,30l8,609, 52,65l10,415, 55,25l7,018 and 51,07l10,255. Differences were not statistically significant. No correlations were observed among bone density, fractal dimension and percentage of bone. Histological analysis showed that MS treated with AB presented newly formed and mature lamellar bone, with active bone formation presenting several vessels and osteoblasts. The other groups showed minor bone formation, with a diffuse marrow and thin network of newly... (Complete abstract click electronic access below) / Orientador: Gulnara Scaf / Coorientador: Elcio Marcantonio Junior / Banca: Maria Lúcia Rubo de Rezende / Banca: Eduardo Sant'Ana / Banca: Eduardo Hochuli Vieira / Banca: Joni Augusto Cirelli / Doutor
3

Osseointegração de implantes usinados e oxidados em seio maxilar preenchido por coágulo com ou sem osso autógeno : estudo histológico, histométrico e de RFA em macacos /

Palma, Vinícius Canavarros. January 2006 (has links)
Resumo: O objetivo deste estudo experimental foi comparar histologicamente o preenchimento do assoalho do seio maxilar por coágulo local com ou sem a associação de osso autógeno (controle), bem como investigar a osseointegração em duas diferentes superfícies de implante sob essas condições, através de medidas histométricas, análises histológicas e em freqüência de ressonância (RFA). Quatro macacos prego (tufted capuchin) tiveram todos os pré-molares e os primeiros molares superiores extraídos. Após quatro meses de reparo, os animais foram submetidos a cirurgia para acessar o assoalho do seio maxilar, através de uma janela óssea, para elevação da membrana do seio. O seio direito foi deixado para que se reparasse espontaneamente (somente coágulo), enquanto o esquerdo foi preenchido com enxerto ósseo autógeno. A membrana dos seios foram mantidas elevadas pela inserção simultânea de dois implantes (um usinado e outro oxidado eletroliticamente, Sistema Branemark®, Nobel Biocare) em cada lado da maxila. A estabilidade dos implantes foi acessada através da freqüência de ressonância (RFA, Ostell®) no momento da fixação dos implantes e no dia do sacrifício. Com a injeção de fluorocromos foi possível investigar o processo de neoformação óssea nos animais bem como relacioná-lo às diferentes superfícies dos implantes. Os animais foram sacrificados 6 meses após a cirurgia para análise histológica e de histomorfometria (contato-osso-implante - BIC, área de osso nas roscas - BA, e área de osso em um retângulo desenhado - BAR). Concluímos que não houve diferença entre o seio preenchido somente com coágulo local e o seio preenchido com osso autógeno, em relação à RFA, BIC, BA e BAR...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This experimental study aimed at comparing histologically the use of coagulum alone or autogenous bone graft (control) for sinus floor augmentation procedures as well as investigating the role played by implants surface on osseointegration under such circumstances, as measured by histological, histometric and resonance frequency analysis (RFA). Four tufted capuchin monkeys had all upper premolars and 1st molar extracted bilaterally. Four months later the animals underwent maxillary sinus floor augmentation surgery using the window technique. The right sinus was left to heal spontaneously (coagulum alone), whilst the left sinus was filled with autogenous bone graft. The Schneider's membrane was kept elevated by insertion of two implants (machined and oxidized, Bränemark System) in both sinuses. Implant stability was assessed through resonance frequency analysis (RFA, Osstell) at installation and at sacrifice. The pattern of bone formation in all experimental sites as well as related to the different implants surface was investigated using fluorochromes. The animals were sacrificed 6 months after MSFA for histology and histomorphometry (bone-to-implant contact - BIC, bone area in threads - BA, and bone area in rectangle - BAR). The results showed no difference between coagulum and bone graft sites regarding RFA, BIC, BA and BAR. As to BIC, the oxidized implants exhibited improved integration compared with machined ones. Oxidized implants showed higher BA compared to machined implants in bone grafts. The amount of bone tissue do not differ in coagulum alone and autogenous bone sites. Histologically, new bone is frequently deposited in contact with Schneider's membrane in coagulum alone sites, confirming the osseoinductive potential of the membrane. The oxidized implants should be preferred to machined implants in sinus floor augmentation procedures. / Orientador: Osvaldo Magro Filho / Coorientador: Luiz Antônio Salata / Banca: Luis Eduardo Marques Padovan / Banca: Renato Mazzonetto / Banca: João Gualberto Cerqueira Luz / Banca: Idelmo Rangel Garcia Júnior / Banca: Paulo Sérgio Perri de Carvalho / Doutor

Page generated in 0.0815 seconds