• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desajuste Marginal de Infra-estruturas metálicas de próteses fixas sobre implantes considerando tipos de pilares, materiais e solda a laser / Marginal misfit of metallic structures of total fixed implant supported prosthesis considering abutments, material and laser welding

PEREIRA, Richard Esteves 24 March 2005 (has links)
Made available in DSpace on 2014-07-29T15:21:57Z (GMT). No. of bitstreams: 1 pre textuais richard esteves pereira.pdf: 111431 bytes, checksum: fed09c5e1bc065f1fe26c77537645e5e (MD5) Previous issue date: 2005-03-24 / The adaptation precision of metallic structures to implant abutments is a very questionable subject and the scientific literature lacks about the alloy that shows an adaptation closer to the ideal. This study had the proposal of: evaluating the vertical marginal misfit levels (in &#956;m) using a digital microscope of one-piece and after laser welding metallic structures of total fixed implant supported prosthesis casted in Nickel-Chrome, Nickel-Chrome-Titanium-Molibidenium and Palladium-Silver alloys and commercially pure Titanium, over two different kinds of abutments and, also, associate the misfit results observed at the one-piece structures phase with the data obtained after the laser welding treatment. After the fabrication of two master models, 40 pre-fabricated copings for both Estheticone and Micro-Unit type abutments were used at the survey. Eight metallic structures were casted with Ni-Cr, Ni-Cr-Ti-Mo, Pd-Ag and Ti-c.p., being two structures for each alloy. The vertical misfit values concerning the relation of the metallic structures and implant abutments from all alloys and on both stages one-piece and after laser welding were tabulated and then submitted to statistical tests. The values were exposed to the ANOVA and the significant statistic means were compared by the Tukey test considering a 5% significance value (p<0.05), as well as the standard deviation. The results evidenced that the one-piece structures showed misfit, but the mean values did not present statistic significant differences. The material (alloys) analysis showed that the Ti-c.p. did not show discrepant mean values, but the same did not occur with the other alloys. The comparison between all alloys showed no significant statistical differences, and, the Pd-Ag alloy (control group) showed the higher misfit mean values at the one-piece phase. The relation between the one-piece and after laser welding phases showed the presence of statistic significant values, based on the mean values (onepiece= 0.0953 &#956;m / laser welding=0.0452 &#956;m) and the marginal vertical misfit after laser welding appeared significantly decreased. / A precisão da adaptação das infra-estruturas sobre pilares de implantes é objeto de inúmeros questionamentos e a literatura ainda é carente em relação à liga que possa apresentar adaptação próxima do ideal. Assim, esta pesquisa teve como propósitos: avaliar os níveis de desajustes marginais verticais (em &#956;m) por meio de microscópio mensurador digital das infra-estruturas metálicas em monobloco e após soldagem a laser de próteses totais fixas fundidas em ligas de Níquel-Cromo, Níquel-Cromo-Titânio-Molibidênio, Paládio-Prata e Titânio Comercialmente Puro assentadas sobre dois tipos diferentes de pilares de implantes e, ainda, correlacionar os resultados obtidos dos níveis de desajustes das infra-estruturas monobloco com os das infra-estruturas pós-soldagem (a laser). A partir de dois modelos-mestre, foram enceradas 40 amostras sobre copings pré-fabricados de pilares de implantes tipo Estheticone e Micro-Unit (Conexão Sistema de Prótese-SP). Obteve-se oito infra-estruturas metálicas a partir da fundição das ligas Ni-Cr, Ni-Cr-Ti-Mo, Pd-Ag e Ti-c.p., sendo duas infraestruturas para cada liga. Os valores correspondentes às leituras das distâncias verticais (em !m) da relação infra-estruturas metálicas e pilares de implantes de todas as amostras das diferentes ligas metálicas utilizadas e das etapas monobloco e soldagem a laser foram tabulados e, em seguida, aplicado os testes estatísticos. Os valores foram sujeitos à análise de variância e as médias com diferenças estatísticas significativas foram comparadas pelo teste de Tukey com nível de significância 5% (p<0,05), bem como o desvio padrão. Os resultados evidenciaram que nas infra-estruturas em monobloco (sem solda), houve a presença de desajuste, porém os valores médios não apresentaram diferenças estatísticas significativas. Na avaliação do material empregado (ligas) verificou-se que as infra-estruturas em Ti-c.p. não apresentaram valores médios discrepantes, o que não ocorreu com as infra-estruturas obtidas com as demais ligas. Na comparação de todas as ligas utilizadas, os seus valores médios não apresentaram diferenças estatísticas significativas e a liga de Pd-Ag (Grupo Controle) foi a que apresentou valor médio de maior desajuste nas estruturas em monobloco. Na correlação das infra-estruturas monobloco e pós-soldagem (a laser), evidenciou-se a existência de diferenças estatísticas significativas, baseado nos valores médios (monobloco 0,0953&#956;m / solda a laser 0,0452&#956;m), sendo o desajuste marginal vertical para a infra-estrutura com solda a laser, significativamente menor.
2

Resistência mecânica e desajuste marginal do titânio comercialmente puro submetido a dois métodos de soldagem: TIG e Laser / Mechanic resistance and marginal misfit of pure Ti submitted to two welding methods TIG and Laser

Atoui, Juliana Abdallah 05 December 2008 (has links)
O objetivo deste trabalho foi avaliar o efeito da soldagem TIG (\"tungsten inert gas\") e compará-la com soldagem a laser, em hastes cilíndricas e supra-estruturas implantosuportadas, confeccionadas em titânio comercialmente puro (Ti cp) por meio dos ensaios de resistência mecânica (tração e flexão) e desajuste marginal, respectivamente. Foram confeccionados noventa corpos-de-prova em titânio cp, sendo sessenta, na forma de hastes cilíndricas, obtidas por fundição de hastes de latão, e trinta na forma de supra-estruturas implanto-suportadas, obtidas por modelo de gesso com quatro análogos de implantes Microunit (Conexão), com dez repetições para cada grupo (controle, solda TIG, solda a Laser). Para a obtenção dos corpos-de-prova, foi realizada inclusão em revestimento Rematitan Plus, de acordo com as instruções fabricante. Os anéis foram submetidos aos ciclos térmicos e posicionados na máquina de fundição (Rematitan), sob arco voltaico, vácuo e atmosfera de argônio, com injeção de titânio sob vácuo-pressão. Após resfriamento, as fundições foram desincluídas e jateadas com óxido de alumínio. Os corpos-de-prova obtidos em forma de hastes cilíndricas foram distribuídos aleatoriamente, em três grupos, para ambos os ensaios, resistência à tração e flexão: grupo controle (sem solda), solda TIG e solda a Laser. As trinta supra-estruturas foram divididas aleatoriamente em três grupos: I- controle - monobloco; II-B- pós-soldagem TIG e III-B- pós-soldagem a Laser; os grupos II-A e III-A, foram constituídos dos espécimes antes do processo de soldagem: II-A- pré-soldagem TIG e III-A- pré-soldagem a Laser. Os dados obtidos para o Ensaio de Tração (MPa) foram analisados estatisticamente pelos testes ANOVA e Tukey (&alpha;= 0,05). O teste complementar de Tukey (p = 0,05) evidenciou que houve diferença entre o grupo controle (605,84 ± 19,83) e os métodos de soldagem TIG (514,90 ± 37,76) e Laser (515,85 ± 62,07). Para o Ensaio de Flexão (MPa), o teste não-paramétrico de Kruskal-Wallis mostrou que não houve diferença estatisticamente significante entre os processos de soldagem TIG (1559,66) e Laser (1621,64), contudo a diferença foi significante entre estes grupos e o controle (1908,75). Para análise dos resultados do desajuste marginal (&mu;m) das supra-estruturas implanto-suportadas, o teste nãoparamétrico de Kruskal-Wallis revelou que não houve diferença estatisticamente significante entre os grupos pós-soldagem TIG (250) e pós-soldagem Laser (241), entretanto, o grupo controle (770) apresentou o maior desajuste. Pelos resultados obtidos e dentro das limitações deste estudo, pode-se afirmar que a soldagem a TIG propicia a obtenção de resultados similares à soldagem a Laser. / The aim of this study was to evaluate the effect of TIG welding (tungsten inert gas) and compare it with Laser welding, of the cylindrical rods and implant-supported frameworks, obtained by in commercially pure titanium (cp) through the mechanical resistance (tensile and flexural strength) and misfit marginal, respectively. Ninety specimens have been fabricated titanium cp, and sixty, cylindrical rods, obtained by casting of the brass rods, and thirty implant-supported frameworks, obtained by plaster die with four similar - Microunit implants (Connection), with ten repetitions for each group (control, TIG welding, laser welding). The specimens were invested in Rematitan Plus, according to the manufacturer instructions. The rings were subjected to thermal cycling and positioned in the machine of casting (Rematitan) under voltaic arc, vacuum and atmosphere of argon, with injection of titanium vacuumpressure. After cooling, were manually and airbone-particle abraded with aluminum oxide. The specimes cylindrical rods were randomly distributed in three groups, for tests, tensile and flexural strength: the control group (without welding), TIG welding and soldering laser. The above thirty-structures were randomly divided into three groups: I- one-piece-cast (control)-, II-B-after-TIG welding and III-B-after-Laser welding, the Group II-A, III-A, consisted of specimens before the process of welding: II-A-before-TIG welding and III-A before-Laser welding. The results for the test Traction were submitted to variance analysis ANOVA (p < 0.05) being observed difference between groups. The supplementary Tukey test (p = 0.05) showed that there was a difference between the control group (605.84 ± 19.83) and the methods of welding TIG (514.90 ± 37.76) and laser (515.85 ± 62.07). To test the Flexion nonparametric test Kruskal-Wallis showed that there was no statistically significant difference between the processes of TIG welding (1559.66) and Laser (1621.64), but the difference was significant between these groups and control (1908.75). For analysis of the results of marginal misfit implant-supported frameworks, the non-parametric Kruskal-Wallis test revealed that there was no statistically significant difference between groups after-TIG welding (250) and after- Laser welding (241), however, the control group (770) showed the largest misfit. With these and the limitations of this study TIG welding in may be to Laser welding.
3

Resistência mecânica e desajuste marginal do titânio comercialmente puro submetido a dois métodos de soldagem: TIG e Laser / Mechanic resistance and marginal misfit of pure Ti submitted to two welding methods TIG and Laser

Juliana Abdallah Atoui 05 December 2008 (has links)
O objetivo deste trabalho foi avaliar o efeito da soldagem TIG (\"tungsten inert gas\") e compará-la com soldagem a laser, em hastes cilíndricas e supra-estruturas implantosuportadas, confeccionadas em titânio comercialmente puro (Ti cp) por meio dos ensaios de resistência mecânica (tração e flexão) e desajuste marginal, respectivamente. Foram confeccionados noventa corpos-de-prova em titânio cp, sendo sessenta, na forma de hastes cilíndricas, obtidas por fundição de hastes de latão, e trinta na forma de supra-estruturas implanto-suportadas, obtidas por modelo de gesso com quatro análogos de implantes Microunit (Conexão), com dez repetições para cada grupo (controle, solda TIG, solda a Laser). Para a obtenção dos corpos-de-prova, foi realizada inclusão em revestimento Rematitan Plus, de acordo com as instruções fabricante. Os anéis foram submetidos aos ciclos térmicos e posicionados na máquina de fundição (Rematitan), sob arco voltaico, vácuo e atmosfera de argônio, com injeção de titânio sob vácuo-pressão. Após resfriamento, as fundições foram desincluídas e jateadas com óxido de alumínio. Os corpos-de-prova obtidos em forma de hastes cilíndricas foram distribuídos aleatoriamente, em três grupos, para ambos os ensaios, resistência à tração e flexão: grupo controle (sem solda), solda TIG e solda a Laser. As trinta supra-estruturas foram divididas aleatoriamente em três grupos: I- controle - monobloco; II-B- pós-soldagem TIG e III-B- pós-soldagem a Laser; os grupos II-A e III-A, foram constituídos dos espécimes antes do processo de soldagem: II-A- pré-soldagem TIG e III-A- pré-soldagem a Laser. Os dados obtidos para o Ensaio de Tração (MPa) foram analisados estatisticamente pelos testes ANOVA e Tukey (&alpha;= 0,05). O teste complementar de Tukey (p = 0,05) evidenciou que houve diferença entre o grupo controle (605,84 ± 19,83) e os métodos de soldagem TIG (514,90 ± 37,76) e Laser (515,85 ± 62,07). Para o Ensaio de Flexão (MPa), o teste não-paramétrico de Kruskal-Wallis mostrou que não houve diferença estatisticamente significante entre os processos de soldagem TIG (1559,66) e Laser (1621,64), contudo a diferença foi significante entre estes grupos e o controle (1908,75). Para análise dos resultados do desajuste marginal (&mu;m) das supra-estruturas implanto-suportadas, o teste nãoparamétrico de Kruskal-Wallis revelou que não houve diferença estatisticamente significante entre os grupos pós-soldagem TIG (250) e pós-soldagem Laser (241), entretanto, o grupo controle (770) apresentou o maior desajuste. Pelos resultados obtidos e dentro das limitações deste estudo, pode-se afirmar que a soldagem a TIG propicia a obtenção de resultados similares à soldagem a Laser. / The aim of this study was to evaluate the effect of TIG welding (tungsten inert gas) and compare it with Laser welding, of the cylindrical rods and implant-supported frameworks, obtained by in commercially pure titanium (cp) through the mechanical resistance (tensile and flexural strength) and misfit marginal, respectively. Ninety specimens have been fabricated titanium cp, and sixty, cylindrical rods, obtained by casting of the brass rods, and thirty implant-supported frameworks, obtained by plaster die with four similar - Microunit implants (Connection), with ten repetitions for each group (control, TIG welding, laser welding). The specimens were invested in Rematitan Plus, according to the manufacturer instructions. The rings were subjected to thermal cycling and positioned in the machine of casting (Rematitan) under voltaic arc, vacuum and atmosphere of argon, with injection of titanium vacuumpressure. After cooling, were manually and airbone-particle abraded with aluminum oxide. The specimes cylindrical rods were randomly distributed in three groups, for tests, tensile and flexural strength: the control group (without welding), TIG welding and soldering laser. The above thirty-structures were randomly divided into three groups: I- one-piece-cast (control)-, II-B-after-TIG welding and III-B-after-Laser welding, the Group II-A, III-A, consisted of specimens before the process of welding: II-A-before-TIG welding and III-A before-Laser welding. The results for the test Traction were submitted to variance analysis ANOVA (p < 0.05) being observed difference between groups. The supplementary Tukey test (p = 0.05) showed that there was a difference between the control group (605.84 ± 19.83) and the methods of welding TIG (514.90 ± 37.76) and laser (515.85 ± 62.07). To test the Flexion nonparametric test Kruskal-Wallis showed that there was no statistically significant difference between the processes of TIG welding (1559.66) and Laser (1621.64), but the difference was significant between these groups and control (1908.75). For analysis of the results of marginal misfit implant-supported frameworks, the non-parametric Kruskal-Wallis test revealed that there was no statistically significant difference between groups after-TIG welding (250) and after- Laser welding (241), however, the control group (770) showed the largest misfit. With these and the limitations of this study TIG welding in may be to Laser welding.

Page generated in 0.0317 seconds