Spelling suggestions: "subject:"marginal gap"" "subject:"arginal gap""
1 |
Influência do modo de foto ativação no grau de conversão, e adaptação marginal e interna de restaurações classe II com resinas compostas bulk fill / Influence of light curing mode on degree of conversion, and marginal and internal adaptation of class II bulk fill resin restorationContreras, Sheila Celia Mondragón 19 January 2017 (has links)
Submitted by SHEILA CELIA MONDRAGÓN CONTRERAS null (sheilamondragon90@gmail.com) on 2018-01-23T00:06:22Z
No. of bitstreams: 1
SHEILA CELIA MONDRAGÓN CONTRERAS(1).pdf: 2157978 bytes, checksum: b607b65c3fd9d6ea2847c3311b4b6805 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-01-23T20:07:33Z (GMT) No. of bitstreams: 1
contreras_scm_me_sjc.pdf: 2157978 bytes, checksum: b607b65c3fd9d6ea2847c3311b4b6805 (MD5) / Made available in DSpace on 2018-01-23T20:07:34Z (GMT). No. of bitstreams: 1
contreras_scm_me_sjc.pdf: 2157978 bytes, checksum: b607b65c3fd9d6ea2847c3311b4b6805 (MD5)
Previous issue date: 2017-01-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a efetividade de diferentes modos de foto ativação das resinas compostas bulk fill comparando com as resinas convencionais, analisando sua influência na irradiância, no grau de conversão, assim como na formação de fendas internas e marginais em restaurações classe II tipo slot vertical, após envelhecimento artificial. Cento e sessenta incisivos bovinos foram cortados e desgastados para simular dentes posteriores, nos quais foram realizados preparos classe II. Os espécimes foram divididos em quatro grupos de acordo com o material restaurador utilizado: Tetric N-Ceram Bulk Fill (TB), Admira Fusion X-tra Bulk fill (AB), Tetric N-Ceram (TC) e GrandioSO (GO). As resinas bulk fill foram inseridas em incremento único de 4 mm e nos demais grupos foi utilizada a técnica incremental oblíqua (2 mm). A foto ativação foi realizada com os aparelhos do tipo Monowave (MW) ou Polywave (PW) nos dois modos (alta intensidade continua e rampa). A medição da irradiância foi feita utilizando espectroradiômetro Patient Simulator (MARC-PS). O grau de conversão foi avaliado através da reflectância total atenuada (ATR) do espectrômetro (FTIR). As superfícies superiores das amostras foram irradiadas in loco durante 20 s. O espectro da superfície inferior foi registrado em tempo real e após 15 min da irradiação. As fendas foram avaliadas em estereomicroscópio (50x). As fendas marginais externas foram avaliadas antes e após a ciclagem termomecânica. Para fenda interna, os espécimes foram seccionados e então avaliados. Os dados foram submetidos à ANOVA umo e dois fatores e teste Tukey. Em relação á irradiância o aparelho LED Monowave apresentou maior valor de irradiância (1822,2 mW/cm2 - AIC; 1748,1 mW/cm2 - R); na análise do GC, o teste ANOVA dois fatores mostrou diferença significativa (p<0,05) para o fator tipo de resina. A resina TB apresentou o menor grau de conversão, e AB o maior GC. Para fenda marginal foi encontrada diferença significativa para o fator fotopolimerização e interação resina x fotopolimerização (p<0,05). Resina TC fotopolimerizada PW/AIC apresentou maior média de fenda marginal (13,94 µm) e TC fotopolimerizada MW/AIC a menor (9,59 µm). Após o envelhecimento termomecânico a resina GO fotopolimerizada PW/R apresentou maior porcentagem de aumento de fenda marginal (48,54%) e maior fenda interna quando fotopolimerizada MW/AIC (85,05 µm). Concluiu-se que o tipo fotopolimerização não influenciou no grau de conversão. As restaurações polimerizadas com o fotopolimerizador Polywave apresentaram os maiores valores de fenda marginal externa. As resinas bulk fill apresentaram menores valores de fenda marginal e interna após o envelhecimento termomecânico quando comparadas com restaurações de resinas convencionais. / The objective of this study was to evaluate the influence of different photo activation modes on irradiance, the degree of conversion and formation of internal and external gaps in class II restorations using bulk fill resins. One hundred and sixty bovine incisors were cut and worn to simulate posterior teeth, in which class II preparations were performed. The specimens were divided into four groups according to the restorative material used: Tetric N-Ceram Bulk Fill (TB), Admira fusion X-tra Bulk fill (AB), Tetric N-Ceram (TC), GrandioSO (GO). The bulk fill resins were inserted in a single increment of 4 mm, and in the other groups, the incremental oblique technique was used. The photo activation was performed with a Monowave (MW) or Polywave (PW) light curing devices selecting two modes (high continuous intensity (HCI) and soft start (SS)). The irradiance measurement was performed using Patient Simulator (MARC-PS) in HCI and SS modes, for 20 s. For the degree of conversion, 2 mm and 4 mm high and 5 mm diameter molds were prepared for resin insertion directly on the attenuated total reflectance (ATR) spectrometer (FTIR). The upper surfaces of the samples were irradiated in situ for 20 s with the light curing apparatus in the modes (HCI) and (SS), the lower surface spectra was recorded continuously in real time and then at 15 min after irradiation. For the evaluation of the external gap each specimen was evaluated twice, one before and one after the thermomechanical cycling. For internal gap, the specimens were sectioned and evaluated using the stereomicroscope using a 50x magnification. About the irradiance, the Monowave LED showed the highest irradiance values (1822,2 mW/cm2 - HCI; 1748,1 mW/cm2 - SS), in the DC analysis, the two way ANOVA test showed significant difference (p <0.05) for the resin type. TB showed the lowest DC, with a statistical difference for AB. For the marginal gap, a significant difference was found for the photopolymerization factor and resin x photopolymerization interaction (p <0.05). TC light cured by PW/HCI showed the highest average marginal gap (13.94 μm) and TC light cured by MW / HCI revealed the lowest (9.59 μm) marginal gap. After thermomechanical aging, GO light cured by PW / SS had a higher percentage of increasing marginal gap (48.54%) and the highest internal gap when light cured by MW / HCI (85.05 μm). It was concluded that the type of photopolymerization did not influence the degree of DC. The restorations light cured by PW device showed the highest external marginal gaps. Bulk fill resins exhibited lower marginal and internal gap values after thermomechanical aging when compared with conventional resin.
|
2 |
Comportamento mecânico, resistência de união e longevidade de pilares e coroas de zircônia obtidas por sistema CAD-CAM: influência de diferentes tratamentos de superfície / Mechanical behavior, bond strength and reliability of YTZP abutments and crowns processed by CAD/CAM: The role of surface treatmentsDantas, Talita Souza 29 April 2015 (has links)
O objetivo do estudo foi avaliar a resistência de união à zircônia após diferentes tratamentos de superfície e o comportamento mecânico de pilares e coroas de zircônia associados aos mesmos tratamentos. Na primeira fase, 95 discos em zircônia foram obtidos e divididos em cinco grupos (n = 19): GC (grupo controle, sem nenhum tipo de tratamento); GAL (jateamento com partículas de Al2O3 antes da sinterização); GALS (jateamento com partículas de Al2O3 após sinterização); GRO (silanização com sistema Rocatec antes da sinterização) e GROS (silanização com sistema Rocatec após sinterização). Três amostras de cada grupo tiveram a superfície analisada em MEV e MCVL. Dez amostras de cada grupo foram submetidas a ensaio de microcisalhamento e as seis restantes foram submetidas à análise de interface por meio de MEV. A análise estatística utilizou modelo de regressão linear com efeitos mistos e teste de Tukey (p < 0,01). Na segunda fase, 70 pilares do tipo hexágono externo foram obtidos em zircônia e associados a coroas totais com copings de zircônia. Os conjuntos análogo-pilar-coroa também foram divididos em cinco grupos (n=14) e submetidos aos mesmos tratamentos previamente descritos. Ainda, foram realizadas mensurações para verificação da adaptação dos copings sobre os pilares e rugosidade superficial dos discos, copings e pilares em MCVL. Foi realizado ensaio de fadiga mecânica dos conjuntos com carga progressiva de 80, 120, 160, 200, 240, 280 e 320 N, frequência de 5 Hz, totalizando 20.000 ciclos em cada estágio. A ciclagem térmica foi realizada com temperaturas entre 5º C e 55º C. Após os ensaios mecânicos, os resultados foram submetidos à análise estatística (probabilidade de sobrevida, teste de Log-Rang, p < 0,05) Os resultados apontaram que o grupo ROS apresentou valores de resistência de união significativamente superiores (p < 0,01) e que a rugosidade superficial foi semelhante para discos e copings (p = 0,22) e para discos e pilares (p = 0,96), e diferente entre copings e pilares (p < 0,01). A desadaptação marginal foi maior para o grupo RO (p < 0,01) e a probabilidade de sobrevida dos conjuntos foi similar para todos os grupos testados (p = 0,57). Concluiu-se que a utilização do Rocatec aumenta os valores de resistência de união à zircônia, não compromete o comportamento mecânico do material e sua utilização é viável em peças já sinterizadas. / The aim of this study was to evaluate the bond strength to zirconia after different surface treatments and to evaluate the mechanical behavior of zirconia abutments and crowns associated with these treatments. In the first phase, 95 discs in zirconia were obtained and divided into five groups (n = 19): GC (control group, without any treatment), GAL (air particle abrasion with Al2O3 particles before sintering), GALS (air particle abrasion with Al2O3 particles after sintering), GRO (silanization with Rocatec system before sintering) and GROS (silanization with Rocatec system after sintering). Three samples of each group had the surfaces analyzed in SEM and CLSM. Ten samples of each group were subjected to microshear test and the other remaining six had their interface examined by SEM. The statistical analysis used a linear regression model with mixed effects and Tukey test (p <0.01). In the second stage, 70 external hex abutments were obtained in zirconia and associated with crowns and zirconia copings. The analog-abutment-crown assemblies were also divided into five groups (n = 14) and subjected to the same treatments described previously. Measurements to verify the adaptation of copings on the abutments and surface roughness of the discs, copings and abutments were performed in CLSM. A fatigue test was carried with progressive load of 80, 120, 160, 200, 240, 280 and 320 N, frequency of 5 Hz and 20,000 cycles at each stage. Thermal cycling was performed with temperatures between 5° C and 55° C. After mechanical tests, the results were subjected to statistical analysis (survival probability, Log-Rang test, p <0.05) The results showed that the ROS group had significantly higher bond strength values (p < 0.01) and that the surface roughness was similar for discs and copings (p = 0.22) and for discs and abutments (p = 0.96), and was different between copings and abutments (p < 0.01). The marginal gap was higher for RO group (p < 0.01) and the survival probability of the sets was similar for all tested groups (p = 0.57). It was concluded that the use of Rocatec increases the bond strength values to zirconia, does not compromise the mechanical behavior of the material and its use is now feasible in sintered parts.
|
3 |
Comportamento mecânico, resistência de união e longevidade de pilares e coroas de zircônia obtidas por sistema CAD-CAM: influência de diferentes tratamentos de superfície / Mechanical behavior, bond strength and reliability of YTZP abutments and crowns processed by CAD/CAM: The role of surface treatmentsTalita Souza Dantas 29 April 2015 (has links)
O objetivo do estudo foi avaliar a resistência de união à zircônia após diferentes tratamentos de superfície e o comportamento mecânico de pilares e coroas de zircônia associados aos mesmos tratamentos. Na primeira fase, 95 discos em zircônia foram obtidos e divididos em cinco grupos (n = 19): GC (grupo controle, sem nenhum tipo de tratamento); GAL (jateamento com partículas de Al2O3 antes da sinterização); GALS (jateamento com partículas de Al2O3 após sinterização); GRO (silanização com sistema Rocatec antes da sinterização) e GROS (silanização com sistema Rocatec após sinterização). Três amostras de cada grupo tiveram a superfície analisada em MEV e MCVL. Dez amostras de cada grupo foram submetidas a ensaio de microcisalhamento e as seis restantes foram submetidas à análise de interface por meio de MEV. A análise estatística utilizou modelo de regressão linear com efeitos mistos e teste de Tukey (p < 0,01). Na segunda fase, 70 pilares do tipo hexágono externo foram obtidos em zircônia e associados a coroas totais com copings de zircônia. Os conjuntos análogo-pilar-coroa também foram divididos em cinco grupos (n=14) e submetidos aos mesmos tratamentos previamente descritos. Ainda, foram realizadas mensurações para verificação da adaptação dos copings sobre os pilares e rugosidade superficial dos discos, copings e pilares em MCVL. Foi realizado ensaio de fadiga mecânica dos conjuntos com carga progressiva de 80, 120, 160, 200, 240, 280 e 320 N, frequência de 5 Hz, totalizando 20.000 ciclos em cada estágio. A ciclagem térmica foi realizada com temperaturas entre 5º C e 55º C. Após os ensaios mecânicos, os resultados foram submetidos à análise estatística (probabilidade de sobrevida, teste de Log-Rang, p < 0,05) Os resultados apontaram que o grupo ROS apresentou valores de resistência de união significativamente superiores (p < 0,01) e que a rugosidade superficial foi semelhante para discos e copings (p = 0,22) e para discos e pilares (p = 0,96), e diferente entre copings e pilares (p < 0,01). A desadaptação marginal foi maior para o grupo RO (p < 0,01) e a probabilidade de sobrevida dos conjuntos foi similar para todos os grupos testados (p = 0,57). Concluiu-se que a utilização do Rocatec aumenta os valores de resistência de união à zircônia, não compromete o comportamento mecânico do material e sua utilização é viável em peças já sinterizadas. / The aim of this study was to evaluate the bond strength to zirconia after different surface treatments and to evaluate the mechanical behavior of zirconia abutments and crowns associated with these treatments. In the first phase, 95 discs in zirconia were obtained and divided into five groups (n = 19): GC (control group, without any treatment), GAL (air particle abrasion with Al2O3 particles before sintering), GALS (air particle abrasion with Al2O3 particles after sintering), GRO (silanization with Rocatec system before sintering) and GROS (silanization with Rocatec system after sintering). Three samples of each group had the surfaces analyzed in SEM and CLSM. Ten samples of each group were subjected to microshear test and the other remaining six had their interface examined by SEM. The statistical analysis used a linear regression model with mixed effects and Tukey test (p <0.01). In the second stage, 70 external hex abutments were obtained in zirconia and associated with crowns and zirconia copings. The analog-abutment-crown assemblies were also divided into five groups (n = 14) and subjected to the same treatments described previously. Measurements to verify the adaptation of copings on the abutments and surface roughness of the discs, copings and abutments were performed in CLSM. A fatigue test was carried with progressive load of 80, 120, 160, 200, 240, 280 and 320 N, frequency of 5 Hz and 20,000 cycles at each stage. Thermal cycling was performed with temperatures between 5° C and 55° C. After mechanical tests, the results were subjected to statistical analysis (survival probability, Log-Rang test, p <0.05) The results showed that the ROS group had significantly higher bond strength values (p < 0.01) and that the surface roughness was similar for discs and copings (p = 0.22) and for discs and abutments (p = 0.96), and was different between copings and abutments (p < 0.01). The marginal gap was higher for RO group (p < 0.01) and the survival probability of the sets was similar for all tested groups (p = 0.57). It was concluded that the use of Rocatec increases the bond strength values to zirconia, does not compromise the mechanical behavior of the material and its use is now feasible in sintered parts.
|
4 |
Análise da efetividade de polimerização, adaptação marginal e interna de restaurações Classe II de resinas compostas de inserção em bloco utilizando diferentes matrizes / Effectiveness of cure, marginal and internal adaptation of Class II bulk-fill composites restorations made with different matrices bandsGutierrez, Natália Cortez [UNESP] 11 February 2016 (has links)
Submitted by NATÁLIA CORTEZ GUTIERREZ null (natycg22@hotmail.com) on 2016-04-05T16:41:57Z
No. of bitstreams: 1
TESE NATALIA CORTEZ GUTIERREZ.pdf: 1565983 bytes, checksum: f66fa4688260558df32b38d76df46e78 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-04-07T19:24:53Z (GMT) No. of bitstreams: 1
gutierrez_nc_dr_sjc.pdf: 1565983 bytes, checksum: f66fa4688260558df32b38d76df46e78 (MD5) / Made available in DSpace on 2016-04-07T19:24:53Z (GMT). No. of bitstreams: 1
gutierrez_nc_dr_sjc.pdf: 1565983 bytes, checksum: f66fa4688260558df32b38d76df46e78 (MD5)
Previous issue date: 2016-02-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi analisar a efetividade de polimerização, a adaptação marginal e interna de resinas compostas para dentes posteriores, empregando diferentes matrizes associadas ao envelhecimento artificial. Cento e vinte incisivos bovinos foram cortados e desgastados para simular dentes posteriores, nos quais foram realizados preparados de Classe II, com o ângulo cavosuperficial gengival em dentina. As cavidades tinham 6 mm de altura (ocluso-cervical), 3 de largura (vestibulo-lingual) e 1,5 de profundidade (mesio-distal). Os espécimes foram divididos em seis grupos de acordo com o material restaurador utilizado: GrandioSO (Voco)– convencional incremental, G-aenial universal flo (GC)– fluída incremental, X-tra fil (Voco)– convencional com inserção em bloco, X-tra base (Voco)– fluída com inserção em bloco, Venus Bulk Fill (Kulzer)– fluída com inserção em bloco e SureFil SDR (Dentsply)– fluída com inserção em bloco. As resinas fluídas com inserção em bloco foram inseridas em incremento de 4 mm e receberam uma cobertura oclusal de 2 mm utilizando a resina GrandioSO, com exceção da X-tra fil que foi coberta com uma camada adicional do mesmo material. Nos demais grupos foi utilizada uma técnica incremental de 2 mm. Metade dos espécimes foi restaurada com matriz metálica e a outra metade com matriz de poliéster. O percentual de polimerização foi mensurado através da dureza Knoop e da relação dureza base/topo. A média da largura das fendas marginais presentes nas margens de cada restauração foi calculada após medição, em micrometros, no microscópio óptico (100x). Os espécimes foram submetidos à ciclagem mecânica (500,000 ciclos) e térmica (1,000 ciclos) e a fenda marginal foi avaliada novamente. Para fenda interna, os espécimes foram seccionados em uma cortadeira de precisão e o comprimento, em milímetros, da parede gengival que apresentava fenda foi mensurado no microscópio óptico. Foi calculada então a porcentagem de fenda em relação ao comprimento total da parede (1,5 mm). Os dados foram submetidos à ANOVA dois e três fatores. Com relação ao percentual de polimerização, houve diferença para o fator resina (p=0,001). As resinas G-aenial universal flo (82,08%) e GrandioSO (84,62%) apresentaram os maiores percentuais de cura. Para fenda marginal foi encontrada diferença significativa para todos os fatores (p<0,05). As resinas Venus Bulk e SDR apresentaram as menores médias de fenda marginal (19,16 e 19,62 µm, respectivamente) e GrandioSO a maior (26,88 µm). As restaurações com matriz de poliéster resultaram em fendas menos largas (21,08 µm) que com matriz metálica (23,27 µm). Todos os grupos apresentaram fendas marginais mais largas após a ciclagem. Com relação à fenda interna, houve diferença apenas para o fator resina (p=0,001). Somente a resina GrandioSO apresentou fenda em mais da metade da parede gengival (53,96%). As resinas de incremento em bloco apresentaram menores valores de fenda marginal e interna do que a resina convencional. Porém, não apresentaram eficiência de cura superior à 80% (dureza da base em relação ao topo). / The aim of this study was to analyze the effectiveness of cure, marginal and internal adaptation of composite resins for posterior teeth using different matrices bands associated with artificial aging. One hundred and twenty bovine incisors were cut and flattened in order to simulate posterior teeth, and then were prepared for class II cavities with gingival cavosurface margin in dentin. Cavities had 6 mm height (occluso-cervical), 3 mm width (bucco-lingual) and 1.5 mm deep (mesio-distal). Specimens were divided into six groups according to the restorative material: GrandioSO (Voco)- conventional, G-aenial universal flo (GC)- flowable, X-tra fil (Voco)- conventional bulk, X-tra base (Voco)- flowable bulk, Venus Bulk Fill (Kulzer)- flowable bulk, and SureFil SDR (Dentsply)- flowable bulk. Bulk-fill composites were placed in single increment of 4mm and received a 2mm occlusal coverage of GrandioSO, with the exception of X-tra fil which was covered with a layer of the same material. The remmaing groups were restored in 2 mm incremental technique. Half of the specimens were restored with metallic and the other half with polyester matrix. Effectiveness of cure was measured by Knoop hardness and the bottom/top hardness ratio was evaluated. The average width of marginal gaps present in the restoration was calculated after optical microscope measuring (100x), in microns. The specimens were subjected to mechanical (500.000 cycles) and thermal cycling (1.000 cycles) and marginal gap was evaluated again. For internal adaptation, the specimens were sectioned and the gap length, in millimeters, present on the gingival wall was measured in an optical microscope. The percentage of gap length in relation to the total length of the wall was also calculated. Data were analyzed with three and two-way ANOVA and Tukey´s test. Regarding effectiveness of cure, significant differences were observed for resin factor. Composites G-aenial universal flo (82.08%) and GrandioSO (84.62%) had the highest cure rates. For marginal gap, significant differences were observed for all factors (p<0.05). Venus Bulk (19.16 µm) and SDR (19.62 µm) had the narrower and GrandioSO (26.88 µm) the wider gap. For matrix factor, groups restored with polyester (21.08 µm) had narrower gaps than metallic (23.27 µm). All groups showed wider gaps after aging. For internal adaptation, the only difference found was for resin factor (p=0.001). Conventional composite GrandioSO presented gap in more than half of the gingival wall (53.96%). Bulk-fill composites showed lower values of marginal and internal gap than conventional composite. However, none of the bulk-fill composites showed efficiency of cure of 80% or more.
|
5 |
Influência de propriedades físico químicas dos materiais resinosos e da técnica de inserção na adaptação marginal de restaurações classe II / Influence of physicochemical properties of resin materials and insertion technique on marginal adaptation of class II restorationsSilvia Maria Ribeiro de Alencar Gonçalves 25 February 2013 (has links)
A contração de polimerização das resinas compostas é uma característica indesejável que compromete a integridade da interface dente/restauração. O objetivo deste estudo foi avaliar in vitro a influência de diferentes materiais usados em restaurações classe II de resina composta, quanto ao grau de conversão, tensão de contração, resistência a flexão, módulo de elasticidade e formação de fenda marginal. Foram realizados preparos classe II com dimensões de 4x4x2mm em terceiros molares recém-extraídos para a avaliação da formação de fenda marginal. As cavidades foram niveladas com cimento de ionômero de vidro Riva Light Cure (SDI) (CIV), resina de baixa contração SureFilSDR (Dentsply) (SDR), resina flow FiltekZ350Flow (3M/ESPE) (Z350F) e resina composta FiltekP90 (3M/ESPE) (P90). As restaurações (n=3) foram avaliadas com lupa estereoscópica. A resistência a flexão foi avaliada por meio de ensaio de flexão em três pontos. Para este ensaio foram confeccionados dez corpos de prova (n=10) de cada material com dimensões de 10x2x1mm. Para o teste de tensão de contração foram utilizados cilindros de polimetacrilato com 5 mm de diâmetro e 13 ou 28mm de comprimento. Os bastões foram fixados na EMIC com um espaço de 2mm entre eles, onde os materiais foram inseridos. Foram realizadas cinco repetições para cada grupo (n=5) e a tensão proveniente da contração foi medida por até 10 minutos após o início da fotopolimerização. O Grau de Conversão (GC) foi determinado por espectroscopia no infravermelho com transformada de Fourier (FTIR). Os resultados foram tratados estatisticamente por análise de variância (ANOVA) e Teste de Tukey (p<0,05). Fenda marginal: Z350F = CIV > SDR = P90. Tensão de contração: Z350F > SDR > CIV = P90. Resistência a flexão: P90 > SDR = Z350F > CIV. Módulo de Elasticidade: P90 > CIV = SDR = Z350F. GC: Z350F = SDR > P90 > CIV. Conclusões: existe correlação entre a formação de fenda marginal e as propriedades físico químicas dos materiais testados, sendo as resinas de baixa contração que proporcionaram melhor adaptação marginal; existe correlação entre resistência a flexão, módulo de elasticidade, tensão de contração e a composição dos materiais, já que os compósitos com melhores resultados foram os que apresentaram os maiores percentuais de carga, no entanto, maior grau de conversão não representou melhores propriedades mecânicas. / The shrinkage of composite resin polymerization is an undesirable characteristic that compromises the integrity of the tooth / restoration interface. The aim of this study was to evaluate in vitro the influence of different materials used in composite resin class II restorations in terms of contraction stress, flexural strength, degree of conversion and marginal gap formation. Class II preparation were performed with 4x4x2mm dimensions in third molars freshly extracted for the evaliation of marginal gap formation. The cavities were filled with Riva Light Cure (SDI) glass ionomer cement (CIV), SureFil SDR (Dentsply) low shrinkage resin (SDR), Filtek Z350Flow (3M/ESPE) flowable composite (Z350F) and Filtek P90 (3M/ESPE) composite resin (P90). The restorations (n = 3) were evaluated with magnifying stereoscopic. The flexural strength was assessed by means of three point bending test. For this test ten specimens (n = 10) of each material were made, each with 10x2x1mm dimensions. For the shrinkage stress test polymethacrylate cylinders with 5 mm in diameter and 13 or 28mm in length were used. Bats were attached to the EMIC with a 2mm space between them, where the materials were inserted. The test were repeated five times for each group (n = 5) and the contraction stress was measured for up to 10 minutes after initiation of photopolymerization. The Degree of Conversion (DC) was determined by Fourier transform infrared (FTIR). The results were statistically analyzed by the variance analysis (ANOVA) and Tukey test (p <0.05). Marginal gap: Z350F = CIV > SDR = P90. Contraction stress: Z350F > SDR> CIV = P90. Flexural strength: P90 > SDR = Z350F > CIV. Elasticity Modulus: P90 > CIV = SDR = Z350F. DC: Z350F = SDR > P90 > CIV. Conclusion: There is a correlation between formation of marginal gap and physicochemical properties of the materials tested whereas low shrinkage resins provided better marginal adaptation; correlation exists between flexural strength, elastic modulus, shrinkage stress and material composition, since better results were obtained from composites with larger quantity of load; higher conversion degree did not represent better mechanical properties.
|
6 |
Influência de propriedades físico químicas dos materiais resinosos e da técnica de inserção na adaptação marginal de restaurações classe II / Influence of physicochemical properties of resin materials and insertion technique on marginal adaptation of class II restorationsSilvia Maria Ribeiro de Alencar Gonçalves 25 February 2013 (has links)
A contração de polimerização das resinas compostas é uma característica indesejável que compromete a integridade da interface dente/restauração. O objetivo deste estudo foi avaliar in vitro a influência de diferentes materiais usados em restaurações classe II de resina composta, quanto ao grau de conversão, tensão de contração, resistência a flexão, módulo de elasticidade e formação de fenda marginal. Foram realizados preparos classe II com dimensões de 4x4x2mm em terceiros molares recém-extraídos para a avaliação da formação de fenda marginal. As cavidades foram niveladas com cimento de ionômero de vidro Riva Light Cure (SDI) (CIV), resina de baixa contração SureFilSDR (Dentsply) (SDR), resina flow FiltekZ350Flow (3M/ESPE) (Z350F) e resina composta FiltekP90 (3M/ESPE) (P90). As restaurações (n=3) foram avaliadas com lupa estereoscópica. A resistência a flexão foi avaliada por meio de ensaio de flexão em três pontos. Para este ensaio foram confeccionados dez corpos de prova (n=10) de cada material com dimensões de 10x2x1mm. Para o teste de tensão de contração foram utilizados cilindros de polimetacrilato com 5 mm de diâmetro e 13 ou 28mm de comprimento. Os bastões foram fixados na EMIC com um espaço de 2mm entre eles, onde os materiais foram inseridos. Foram realizadas cinco repetições para cada grupo (n=5) e a tensão proveniente da contração foi medida por até 10 minutos após o início da fotopolimerização. O Grau de Conversão (GC) foi determinado por espectroscopia no infravermelho com transformada de Fourier (FTIR). Os resultados foram tratados estatisticamente por análise de variância (ANOVA) e Teste de Tukey (p<0,05). Fenda marginal: Z350F = CIV > SDR = P90. Tensão de contração: Z350F > SDR > CIV = P90. Resistência a flexão: P90 > SDR = Z350F > CIV. Módulo de Elasticidade: P90 > CIV = SDR = Z350F. GC: Z350F = SDR > P90 > CIV. Conclusões: existe correlação entre a formação de fenda marginal e as propriedades físico químicas dos materiais testados, sendo as resinas de baixa contração que proporcionaram melhor adaptação marginal; existe correlação entre resistência a flexão, módulo de elasticidade, tensão de contração e a composição dos materiais, já que os compósitos com melhores resultados foram os que apresentaram os maiores percentuais de carga, no entanto, maior grau de conversão não representou melhores propriedades mecânicas. / The shrinkage of composite resin polymerization is an undesirable characteristic that compromises the integrity of the tooth / restoration interface. The aim of this study was to evaluate in vitro the influence of different materials used in composite resin class II restorations in terms of contraction stress, flexural strength, degree of conversion and marginal gap formation. Class II preparation were performed with 4x4x2mm dimensions in third molars freshly extracted for the evaliation of marginal gap formation. The cavities were filled with Riva Light Cure (SDI) glass ionomer cement (CIV), SureFil SDR (Dentsply) low shrinkage resin (SDR), Filtek Z350Flow (3M/ESPE) flowable composite (Z350F) and Filtek P90 (3M/ESPE) composite resin (P90). The restorations (n = 3) were evaluated with magnifying stereoscopic. The flexural strength was assessed by means of three point bending test. For this test ten specimens (n = 10) of each material were made, each with 10x2x1mm dimensions. For the shrinkage stress test polymethacrylate cylinders with 5 mm in diameter and 13 or 28mm in length were used. Bats were attached to the EMIC with a 2mm space between them, where the materials were inserted. The test were repeated five times for each group (n = 5) and the contraction stress was measured for up to 10 minutes after initiation of photopolymerization. The Degree of Conversion (DC) was determined by Fourier transform infrared (FTIR). The results were statistically analyzed by the variance analysis (ANOVA) and Tukey test (p <0.05). Marginal gap: Z350F = CIV > SDR = P90. Contraction stress: Z350F > SDR> CIV = P90. Flexural strength: P90 > SDR = Z350F > CIV. Elasticity Modulus: P90 > CIV = SDR = Z350F. DC: Z350F = SDR > P90 > CIV. Conclusion: There is a correlation between formation of marginal gap and physicochemical properties of the materials tested whereas low shrinkage resins provided better marginal adaptation; correlation exists between flexural strength, elastic modulus, shrinkage stress and material composition, since better results were obtained from composites with larger quantity of load; higher conversion degree did not represent better mechanical properties.
|
Page generated in 0.0663 seconds