Spelling suggestions: "subject:"mass spectrometry"" "subject:"dass spectrometry""
101 |
Mass spectrometry of lens fiber membrane proteinsShearer, David B. 03 April 2012 (has links)
Gap junctions are communicating junctions between cells that allow small molecules to pass from the cytoplasm of one cell to the cytoplasm of an adjacent cell. The pores of gap junctions are comprised of two adjacent connexons on neighboring cells, and each connexon is comprised of six connexin proteins. The eye lens of vertebrates is an avascular tissue that is dependent on gap junctions for the distribution of nutrients as well as the removal of waste products. In addition, as the lens cells develop into fibers, they lose their intracellular organelles including the membrane-bound organelles, and are highly dependent on connexons for movement of metabolites and waste materials. Only two connexins, in Bos Taurus Cx44 and Cx49, are highly expressed in lens fiber cells. Thus, the lens offers an excellent system for studying gap junctions. In this study, high-pressure liquid chromatography (HPLC) and mass spectrometry (MS) techniques were used to isolate and characterize connexin proteins from the eye lens of the cow and mouse. Despite over 300 proteins being identified from bovine lens using MS techniques, it was still possible to identify the two connexin proteins following proteolytic digests and MS analysis of the resultant peptides. Several post- translational modifications (PTMs) were identified and characterized in lens fiber connexins, including phosphorylations, acetylations and deamidations and proteolytic cleavages. Changes in phosphorylation of several other lens proteins upon the activation of protein kinase C were also identified.
Detection of the orthologous proteins in mouse lens proved more challenging, but peptides derived from both connexin proteins were also detected from this tissue and PTMs of mouse connexins were also observed. Glutathione-S-transferase fusions to mouse Cx44 and Cx50 were used to identify a number of proteins that may interact with the mouse connexins, and the relevance of those interactions was considered.
The utility of mass spectrometry to the identification of specific proteins from complex mixtures was clearly demonstrated, and its application to understanding the functional relevance of PTMs was discussed.
|
102 |
Enzymatic Digestion in Aqueous-Organic Solvents: A Mass Spectrometry-Based Approach in Monitoring Protein Conformation ChangesTuvilla, Mavreen Rose 03 October 2013 (has links)
The three dimensional structure of a protein is important for its function. When misfolded, a protein may be rendered inactive or adapt a conformation that could be toxic. Studying protein folding requires an understanding of protein conformation. Traditionally, protein conformation has been studied using x-ray crystallography and nuclear magnetic resonance (NMR). X-ray crystallography is limited in the analysis of crystallized proteins and is computationally intensive. NMR deals with proteins in solution but reports only an average of conformation and the technique severely suffers from spectral overlapping due to the thousands of resonances of the protein. More recently, mass spectrometry has been employed not only to elucidate primary structures but also gather information on the three-dimensional conformation of proteins.
In this study, a mass spectrometric-based approach is used to study the changes in conformation of cytochrome c and the green fluorescent protein when subjected to aqueous-organic solvent systems. The technique involved trypsin digestion and generation of peptide mass maps.
For cytochrome c, the experiments were done with ethanol, methanol and acetonitrile to gain insights on naturation and denaturation. An apparent solvent effect to the rate of digestion and propensity for missed cleavages attributed to weakening of hydrophobic interactions and strengthening of intramolecular hydrogen bonding was observed.
For the green fluorescent protein, sulfolane, a known supercharging agent, was used to gain insights on the effect of supercharging to protein conformation. Addition of 2.0% sulfolane shifted the charge state envelope of the protein towards lower m/z while adding lower amounts of sulfolane enhanced lower charge states while broadening the charge state envelope. The time course study showed different patterns of digestion dependent on solvent conditions implying changes in conformation. Furthermore, absorbance and fluorescence measurements suggested that addition of sulfolane protects the fluorophore from quenching. The activity of trypsin is not affected by addition of low amounts of sulfolane.
|
103 |
First tests of a square wave radio frequency quadrupole cooler and buncher for TITANBlomeley, Laura Gail. January 2007 (has links)
A high frequency, large amplitude helium filled RFQ (Radio Frequency Quadrupole) beam cooler and buncher was developed and tested for use in the TITAN (TRIUMF's Ion Trap for Atomic and Nuclear science) Penning trap mass spectrometer facility. This device will cool and bunch radioactive ion beams for use in TITAN's high precision mass measurements of short-lived isotopes and other experiments. A test stand was built to test the transmission and properties of ions from a surface ion source through injection optics, the linear Paul trap RFQ and the extraction optics in both continuous and pulsed modes. The efficiency of the device was determined to be on the order of 60% in continuous mode. The present measurements confirm a transverse emittance of the extracted beam in bunched mode operation of 4 pi-mm-mrad at an extraction energy of 4 keV.
|
104 |
A mass measurement of the short-lived halo nucleus ¹¹Li with the TITAN Penning trap spectrometerSmith, Mathew Jonathon 05 1900 (has links)
New measurements of the masses of the isotopes⁸,⁹,¹¹Li were made using recently commissioned TITAN Penning trap mass spectrometer at TRIUMF. The measurement of the halo nucleus ¹¹Li represents a new standard in Penning trap mass spectrometry, as it is the shortest lived, t₁/₂ = 8.8 ms, isotope ever weighed using this technique. Low energy, E = 20 keV, beams of these radioactive isotopes were produced using the ISAC facility. These were subsequentlycooled and bunched using a square-wave-driven Radio-
Frequency Quadrupole (RFQ) ion guide, which was filled with hydrogen
gas. The cooled ion bunches were then passed into a Penning trap where
the mass measurements were made.
A description of the RFQ in the ISAC hall is given along with some
results from the commissioning of the device. A new set of harmonic deceleration
optics is presented which have been successfully used to inject ions
into the RFQ. Cooling of lithium ions with high DC efficiencies of 20%, in
helium, and 40%, in hydrogen, are shown. Extraction of extremely short
ion bunches, 30 ns FWHM, is also demonstrated. Storage times for stable
lithium ions in helium and hydrogen were investigated. It was found that
lithium ions could be cooled in hydrogen for up to 30 ms without significant
losses whereas cooling in helium lead to exponential losses with a half-life of
5.7(1)ms. The TITAN Penning trap is described and the ⁸,⁹,¹¹Li data presented.
Final values for the mass excess of ∆(⁸Li) = 20945.70(38) keV, ∆(⁹Li) =
24954.80(60) keV and ∆(¹¹Li) = 40728.1(12) keV are obtained. The ⁹,¹¹Li
results are then used to obtain a new value for two neutron separation energy
of ¹¹Li, S₂n = 369.3(1.3) keV. This agrees with the recent measurement from
the MISTRAL spectrometer, 376(5) keV, at the two sigma level, but shows
over three standard deviations from the most recent atomic mass evaluation,
300(20) keV
|
105 |
New frontiers for mass spectrometry in forensic science :Coumbaros, Ioannis. Unknown Date (has links)
Thesis (PhDAppliedScience)--University of South Australia, 2002.
|
106 |
Analysis of organic explosives residues in water by solid phase micro-extraction in combination with gas chromatography - mass spectrometry /Likadja, Dra. Leely L. Herewila Unknown Date (has links)
Thesis (MAppSc(Chem))--University of South Australia, 2000
|
107 |
The characterisation and fragmentation of peptides by mass spectrometry / by Adrian Morley Bradford.Bradford, Adrian Morley January 1996 (has links)
Copies of author's previously published articles inserted. / Bibliography: leaves 191-213. / xiv, 213 leaves : ill. (some col.) ; 30 cm. / Title page, contents and abstract only. The complete thesis in print form is available from the University Library. / Thesis (Ph.D.)--University of Adelaide, Dept. of Chemistry, 1997
|
108 |
Negative ion mass spectrometry of the carbonyl groupJanposri, Sompong January 1976 (has links)
v, 157 leaves : ill. ; 30 cm. / Title page, contents and abstract only. The complete thesis in print form is available from the University Library. / Thesis (Ph.D.)--University of Adelaide, Dept. of Inorganic Chemistry, 1977
|
109 |
Some studies in organic mass spectrometryNussey, Brian January 1974 (has links)
Reprints of five arricles by the author bound in at back of volume / iv, 201 leaves : ill. ; 27 cm. / Title page, contents and abstract only. The complete thesis in print form is available from the University Library. / Thesis (Ph.D.)--University of Adelaide, Dept. of Organic Chemistry, 1974
|
110 |
Mechanistic studies in organic mass spectrometryWhite, Peter Yelland January 1971 (has links)
iv, 173 leaves : ill., offprints / Title page, contents and abstract only. The complete thesis in print form is available from the University Library. / Thesis (Ph.D.)--University of Adelaide, Dept. of Organic Chemistry, 1972
|
Page generated in 0.0638 seconds