• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 907
  • 81
  • 78
  • 78
  • 78
  • 68
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 922
  • 922
  • 454
  • 392
  • 234
  • 208
  • 160
  • 149
  • 100
  • 97
  • 81
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
421

Avaliação da reação tecidual de uma resina termoplástica em tecido subcutâneo de ratos /

Alfenas, Elizabeth Rodrigues. January 1995 (has links)
Orientador: José Roberto Sá Lima / Banca: Plínio Moroni / Banca: Lauro Cardoso Villela / Resumo: A reação tecidual do subcutâneo de ratos foi avaliada por meio da implantação de corpos de prova de uma resina termoplástica (T AK Hydroplastic-DFL). A resina termoplástica foi testada em suas diferentes cores (rosa, amarela, azul e branca). Utilizamos como grupo controle a resina acrílica termicamente ativada incolor. Os corpos de prova em forma de pastilhas, com aproximadamente 8 mm de diâmetro por 1 mm de espessura, foram inseridos em lojas cirúrgicas preparadas no dorso dos animais, que foram sacrificados após os períodos de observação de 2, 3, 6, e 12 semanas. Os tecidos adjacentes aos implantes foram removidos, receberam tratamento histológico de rotina, coloração pela hematoxilina e eosina e pelo tricrômio de Mallory. Os resultados foram analisados por microscopia óptica, e o tecido subcutâneo adjacente aos implantes de resina termoplástica exibiu reação inflamatória moderada nos períodos iniciais de observação (2 e 3 semanas) com reparação da área e formação de cápsula fibrosa envolvendo todos os corpos de prova no período final de 12 semanas. Os resultados obtidos nos permitiram concluir que: • a resina termoplástica nas cores rosa, amarela, azul e branca, não determinou reação tecidual desfavorável em 12 semanas de implantação; • a resina do Grupo controle e a resina termoplástica azul determinaram uma resposta tecidual menos favorável do que a da resina termoplástica nas cores rosa, amarela e branca / Abstract: Subcutaneous rat tissue reaction was evaluated using samples of a thermoplastic resin(TAK Hydroplastic-DFL) of different colours: pink, yellow, blue and white. As control, a transparent thermally activated acrylic resin was used. Samples with a diameter of approximately 8 mm and thickness of 1 mm were implanted in surgical wounds on the back of rats, which were then sacrificed at periods of 2, 3, 6, and 12 weeks. The adjacent tissue was removed and prepared histologically using hematoxilin-eosin and Mallory trichrorne techniques. Through optical microscopy, it was observed that the subcutaneous adjacent to the resin implants showed a moderate inflammatory reaction during the weeks 2 and 3. At the end of week 12, tissue recovery and capsular formation surrounding the resin implant were observed. It was concluded that: • the thermoplastic resin in pink, yellow, b1ue and white colours didn't determine unfavourable tissue reaction in the 12 weeks of implantation; • the resin of the control group and the blue thermoplastic resin determined a tissue response that was less favourable than the thermoplastic resin in pink, yellow and white colours / Mestre
422

Contração de polimerização e expansão higroscópica de resinas compostas: análise pela técnica de video-imagem /

Borges, Alexandre Luiz Souto. January 2014 (has links)
À fundação de Amparo à Pesquisa do estado de São Paulo (FAPESP) / Banca: Estevão Tomomitsu Kimpara / Banca: Rafael Leonardo Xediek Consani / Banca: Mário Alexandre Coelho Sinhoreti / Banca: Marcelo Coelho Goiato / Banca: Regina Tamaki / Resumo: O presente estudo teve como finalidade avaliar a contração de polimerização e o efeito volumétrico da sorção de água (expansão higroscópica), por meio do aumento de volume, registrado pela técnica de video-imagem. Métodos: Treze tipos de resinas compostas (n=10) de 8 fabricantes com diferentes características físicas, tipos e quantidade de carga, viscosidade, polímeros constituintes e aplicação clínica com cor A2 para dentina (4Seasons, Grandio, Venus, Amelogen Plus, P90, Z350, Esthet-X, Amaris, Vita-l-escence, Natural-Look, Charisma, Z250 and Opallis), foram avalidos. A porcentagem de contração de polimerização foi calculada usando um aparelho de video-imagem (ACUVOL - Bisco Dental), onde volumes iguais foram padronizados usando uma matriz de poliuretano em forma de calota com 3mm de diâmetro e 2mm de altura e após 5 minutos de descanso no pedestal do aparelho o volume inicial da massa foi medido e calculado para servir como valor inicial (baseline) e 18J de energia fornecidos a massa por meio de uma unidade de luz LED para fotopolimerização e assim calcular o valor da contração de polimerização de cada resina. Os espécimes então foram armazenados em ambiente seco e com ausência de luz e após 24 horas medidos novamente para verificação do novo volume inicial. A partir deste dados todos os espécimes foram termociclados em uma sequencia de 5.000, 10.000, 15.000 e 20.000 ciclos completos em água destilada a 5°C e 55°C. Ao final de cada marcação os corpos de prova foram secos com um leve jato de ar por 15s e levados novamente à máquina de medição, para compararmos com o volume final. Resultados: O teste ANOVA uma fator para medidas repetidas (α = 0.05) foi aplicado e mostrou que todas as resinas tiveram o volume influenciado pelo número de ciclos térmicos. Os volumes após 5 minutos da polimerização (12,47 ± 0,08) foi significantemente menor que o da porção total inicial... / Abstract: To evaluate the volumetric changes due to polymerization and thermocycling on different resin-composites. Methods: Thirteen A2 Universal Dentin shade resin-composites (n = 10) from eight manufacturers were evaluated (4Seasons, Grandio, Venus, Amelogen Plus, P90, Z350, Esthet-X, Amaris, Vita-l-escence, Natural-Look, Charisma, Z250 and Opallis). The polymerization shrinkage percentage (PS) was calculated using an image measurement device (ACUVOL - Bisco Dental). Equal volumes of material, standardized by a semisphere polyurethane matrix (d = 3mm) were used and, after 5 minutes of relaxation, the baseline volume measurements were obtained with 18 J of energy dose from the LED light-curing unit. Measurements were obtained after 5 minutes and PS values calculated. Specimens were stored in a drydark environment for 24 hours and re-measured. Specimens were then thermocycled in distilled water between 5oC and 55oC for 20,000 cycles, subjected to another volume measurement at 5,000 cycle intervals. Specimens were gently dried prior to each measurement. Results: Repeated measurements were made using ANOVA (α = 0.05) showed that all resin-composite volumes were influenced by the number of cycles. Volumes at 5 minutes post-polymerization (12.47 ± 0.08) were significantly lower than those at baseline (12.80 ± 0.09). Volumes at 24 hours (12.43 ± 0.19) were insignificantly lower than those at 5 minutes postpolymerization. With regards to the impact of thermocycling, all specimens showed statistically significant increases in volume after 5,000 cycles (13.04 ± 0.22). Although statistically different from those after 5,000 cycles, there was no statistically significant difference between volumes measured at 10,000 (12.87±0.21), 15,000 (12.92±0.24), and 20,000 (12.84±0.23) cycles. Conclusion: According to the video-imaging analysis, thermocycling caused a significant expansion in resin-composites tested, the volume increase was not able to...
423

Avaliação in vitro da eficácia e durabilidade da ação de agentes dessensibilizantes na redução da permeabilidade dentinária /

Sales, Ana Luisa Leme Simões. January 2013 (has links)
Orientador: Carlos Rocha Gomes Torres / Banca: Alessandra Bühler Borges / Banca: Andréa Anido Anido / Resumo: O objetivo desse estudo foi avaliar o efeito de diferentes tipos de agentes dessensibilizantes na redução da permeabilidade dentinária, verificada após ciclos de escovação. Material e Método: Foram utilizados 60 dentes incisivos bovinos, obtendo-se discos de dentina com 6 mm de diâmetro e 1 mm de espessura, e um modelo de câmara dividida, conectada a uma fonte de pressão hidrostática. A permeabilidade dentinária máxima foi medida após a remoção da smear layer e abertura tubular. Os espécimes foram divididos em 6 grupos (n=10), de acordo com o dessensibilizante utilizado: PF)Profluorid Varnish - Verniz a base de NaF a 5% (Voco); BF)Bifluoride 12 - Verniz a base de NaF a 6% e CaF2 a 6% (Voco); AP)Admira Protect (Voco); CS) Colgate Sensitive Pro-Alívio para uso profissional (Colgate); NP) NanoP (FGM); CON) Grupo controle - Nenhum tratamento. Após a aplicação, os espécimes foram imersos em saliva artificial por 24 h e a permeabilidade mensurada. A seguir eles foram submetidos a 10.950 ciclos de escovação e a permeabilidade novamente mensurada. Os dados foram submetidos ao teste estatístico ANOVA um fator e o teste de tukey (p<0,05). Resultados: Porcentagem media da permeabilidade em relação ao valor máximo: AP 13,22A; PF 23,45A; NP 23,84A; BF 25,14A; CS 54,59B; CON 89,39C. Porcentagem media da permeabilidade em relação ao valor máximo depois da escovação: AP 15,10A; NP 24,87AB; PF 28,73AB; BF 33,92AB; CS 37,71B; CON 94,46. Conclusão: Todos os dessensibilizantes testados tiveram efeito na redução da permeabilidade em relação ao grupo controle. Em relação ao valor inicial, a aplicação do Admira Protect, NanoP, Profluoride e Bifluoride 12 mostraram efeitos similares na redução da permeabilidade, mas tiveram efeito maior em comparação com a Colgate Sensitive. Depois da escovação, apenas Admira Protect mostrou um efeito maior em relação a Colgate Sensivite, embora as diferenças não sejam.... / Abstract: The aim of this study was to evaluate the different types of agents in the desensitizing reduction. This was verified after brushing cycles. Material and method: There have been used 60 (sixty) bovine incisive teeth, from which 6 mm diameter and 1 mm thick dentine discs were obtained. The dentin permeability was measured in the presence of the smear layer, and after the tubular opening. The samples were divided in six groups (n=10), in accordance with the agent used: PF) Profluorid Varnish - varnish based on NaF 5% (Voco); BF) Bifluoride 12 - varnish based on NaF 6% and CaF 6% (Voco); AP) Admira Protect (Voco); CS) Colgate Sensitive Pro-Relief for professional use (Colgate); NP) NanoP (FGM); CON) Control Group - no treatment. After the experiment the samples were immersed in artificial saliva for 24 h and the permeability was measured. After that, they went through 10.950 brushing cycles, and their permeability measured again. The data were submitted to the statistics ANOVA test, one factor and the Tukey test (p<0,005). Results: Percentage of permeability compared with the maximum: AP 13,22A; PF 23,45A; NP 23,84A; BF 25,14A; CS 54,59B; CON 89,39C The values after brushing were: AP 15,10A; NP 24,87AB; PF 28,73AB; BF 33,92AB; CS 37,71B; CON 94,46. Conclusion: All the agents tested succeeded in the permeability reduction in comparison with the control group. In reference to the initial value the use of Admira Protect, NanoP, Profluoride and Bifluoride 12 proved similar effects in the reduction, but a greater one comparing with Colgate Sensitive. After brushing only Admira Protect proved a greater effect compared to Colgate Sensitive, although the differences cannot be considered as significant, or even observed on others / Mestre
424

Efeito da inclusão de fibras de vidro na resistência flexural e módulo de elasticidade de resinas compostas indiretas em função da espessura e do padrão de poilimerização /

Mello, Elson Braga de. January 2004 (has links)
Orientador: José Roberto Rodrigues / Resumo: Este estudo ín vitro avaliou a influência da inclusão de fibras de vidro em resinas compostas lndiretas, visando confirmar a possibilidade de redução de sua espessura, sem prejuízo a resistência flexural e módulo de elasticidade. Foram constituídos 18 grupos de três materiais restauradores, cada um com diferente padrão de polimerização (Artglass - Heraeus Kulzer; BelleGiass - KerrLab e Targis -lvoclar Vivadent), em três diferentes espessuras (1mm; 1,5mm e 2mm), sem ou com inclusão de fibras (Fibrex Medial, Angelus e Vectris, lvoclar Vlvadent), além de três grupos experimentais, de diferentes espessuras, associando Targis/Fibrex. Os corpos-de-prova (25x2x2mm) foram armazenados em água destilada a 37ac por 24h, e, após, submetidos a ensaio de flexão em máquina universal de ensaios (EMIC DL2000). Os resultados, analisados por ANOVA one-way e testes de Ounnet e Tukey (u=0,05), apontaram diferenças entre os materiais, com BelleGiass exibindo maiores médias de resistência flexural e módulo de elasticidade, e, ainda, aumento significativo da resistência flexural em todos os materiais quando reforçados por fibras, sem benefício ao módulo de elasticidade. A fibra Fibrex foi superior à Vectris, sem diferença estatística. Em relação às espessuras, verificou-se que os espécimes de 1 mm, com reforço, exibiram comportamento semelhante aos de 2mm, sem retorço, com todos os materiais. Foi possível concluir que a inclusão de fibras de vidro propiciou aumento da resistência flexural dos materiais testados, sugerindo viabilidade da redução de desgaste dentário sem prejuízo às propriedades flexurais / Abstract: The aim of thís in vitro study was to evaluate the influence of glass-fiber reínforcement on indirect composíte resins, to confírm the víabílity of thickness reduction with no damage of ffexural strength and elastic modulus. Eighteen groups (n=10) of three restoratíve materiais with different pofymerization patterns (Artglass- Heraeus-Heraeus Kulzer; BelleG/ass- KerrLab and Targis- /voclar Vivadent-Vivadent) and wíth three tickness (1mm, 1,5mm and 2mm) were constituted and half of them received glass-fiber reinforcement (Vectris, lvoclar Vivadent and Fibrex, Angelus). Therefore, three experimentais groups were constituted with Targis!Fibrex. The specimens (25x2x2mm) were stored in distilled water at 37"'C for 24h and them submitted a three-poínt bend test on universal testing machine (EM/C DL2000). The statistical analysis (One-way ANOVA and post-hoc comparisons, a =. 05) of the resufts suggested differences ln polymerization patterns among the materiais with BelleGiass exihibiting greater flexural strength (FS) and elastic modulus (EM). The strength of Fibrex was slightly greater than Vectrís. There were no statistic dífferences. As for the thicknesses, the 1 mm reínforced-composites were similar in strength to the 2mm samples without g/ass-fiber reinforcement for ali materiais. Jt was concluded that the inc/usion of glass-fiber a!lowed greater FS of the tested materiais, suggesting the decreasíng of the dental wear with no damage to the flexural properties for avaliated indirect composite resíns / Doutor
425

Avaliação in vitro da resistência estrutural em dentes fragilizados utilizando reforços intra-radiculares /

Carvalho, Cláudio Antonio Talge. January 2002 (has links)
Orientador: Marcia Carneiro Valera / Banca: Silvia Lustosa de Castro / Banca: Maria Antonia Pereira / Banca: Alberto Siqueira e Silva / Banca: Ana Paula Martins Gomes / Resumo: Dentes com rizogênese incompleta quando sofrem trauma com conseqüente necrose pulpar permanecem com suas paredes dentinárias finas e fragilizadas, tornando-se mais suscetiveis a reincidências de fraturas. A proposta deste trabalho foi avaliar através do teste de compressão a resistência à fratura de dentes bovinos fragilizados que receberam reforços intra-radiculares com resina composta ou pino de fibra de zircônia. Para tanto, utilizou-se 56 dentes bovinos, os quais tiveram suas coroas seccionadas padronizando o tamanho das raízes em 30mm. Os dentes foram divididos em quatro grupos experimentais (14 dentes} e, com exceção do grupo 04 (Controle negativo), todos os canais radiculares foram preparados biomecanicamente até o instrumento de nº 80 e alargados com brocas Gates-Glidden nos 3, 4, 5 e 6 até 20mm de profundidade. A porção coronária foi alargada com broca diamantada tronco cônica nº 721 até a junção cemento-esmalte vestibular e, com broca diamantada tronco cônica nº 716, realizou-se a fragilização das paredes dentinárias do canal radicular a 20mm de profundidade, deixando aproximadamente 2mm de espessura em cada parede. Após, as raízes foram divididas em grupos: grupo 01-receberam reforço intra-radicular com resina composta, fotopolimerizada com o auxílio do sistema Luminex , seguida da obturação do canal; grupo 02-obturação do canal deixando os 10mm apicais com material obturador, e reforço intra-radicular com pino de fibra de zircõnia cimentado com cimento resinoso; o grupo 03-(Controle positivo) não recebeu reforço intra-radicular e foi obturado pela técnica da condensação lateral ativa; no grupo 04-(Controle negativo), os dentes não foram fragilizados. Os espécimes foram embutidos em blocos metálicos, os quais foram adaptados a um dispositivo cilíndrico, de modo que os espécimes foram fixados a 45°. Este dispositivo foi adaptado a um... / Abstract: lmmature teeth when suffer trauma with consequent necrosis pulpar they stay with its dentinal walls thin and brittle, becoming more susceptible to the second injuries. The purpose of this work is to evaluate through the compression test, the resistance to fracture of teeth bovine brittleness that received reinforcements within the root canal with composite resin or pins of zircônia fiber. lt was used 56 bovine teeth, which had its crowns sectioned in the medium third standardizing the size of the specimens in 30mm of length. The teeth were divided in four experimental groups (14 teeth) and, except for the group 04 (negative control), all the root canal was instrumented to #80 and enlarged firstly with drills Gates-Glidden numbers 3, 4, 5 and 6 to 20mm of depth, after, lhe coronary portion was enlarged with the conical drill number 721 until the cementoenamel junction facial and, with lhe conical drill number 716, the brittleness of the dentinal walls of the root canal at 20mm of depth, leaving 2mm of thickness approximately in each wall. After, the specimens of the group 01 received reinforcement within the root canal with composite resin, that was cured by aid of the Luminex system and, after, they were obturated; in lhe group 02, the specimens were obturated. Just leaving the 10mm apical with material, and they received reinforcement within the root canal with zircônia fiber pins cemented with resinous cement; the group 03 (positive control) it didn't received reinforcement within the root canal and it was obturated by the technique of the active lateral condensation; in the group 04 (negative control), the teeth were not brittleness. After, all the specimens were embedded with acrylic resin chemically activated, in metallic blocks, which were adapted to a cylindrical device, so that the specimens were fractured by load in angle of 45°. This device was adapted to a lnstron machine, ... / Doutor
426

Efeitos do tipo de sistema adesivo e região do dente sobre a resistência adesiva à dentina /

Melo, Renata Marques de. January 2005 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Paulo Sérgio Mutarelli / Banca: Carlos Rocha Gomes Torres / Resumo: Este estudo foi realizado no intuito de avaliar a resistência de união à dentina coronária e do canal radicular com dois sistemas adesivos de condicionamento total (dois e três passos) e um sistema autocondicionante. Os canais de trinta incisivos e caninos humanos superiores foram instrumentados e preparados com brocas. Os pinos usados na cimentação foram réplicas em cimento resinoso dual Duo-link do pino Aestheti Plus #2. Assim, constituíram-se três grupos (n = 10), segundo o sistema adesivo utilizado: condicionamento total três passos (CT3) - AII-Bond 2 + pino em cimento resinoso (pcr)+ Duo-link (DI); condicionamento total 2 passos (CT2) - One-Step Plus + pcr + DI; autocondicionante (AC) - Tyrian/One-Step Plus+ pcr + DI. Apôs a cimentação, foram obtidas oito secções transversais (1,5mm), a partir de 4mm acima da JEC até 4mm aquém do ápice do canal, envolvendo dentina coronária e radicular. As secções foram submetidas ao ensaio de push-out em máquina de ensaio universal EMIC (1 mm.min-1). Os dados de resistêncía adesiva foram analisados com o teste ANOVA de dois fatores de medidas repetidas (α<0,05). Foi observado que o efeito interação foi estatisticamente significante, isto é, o relacionamento entre os adesivos não foi o mesmo para as diferentes regiões. Comparando-se as médias obtidas com os adesivos em cada região (Tukey; α<0,05), observou-se que o CT3 (média± desvio padrão: 5,22 ± 1,70) foi superior ao CT2 (2,60 ± 1,74) e ao AC (1,68 ± 1,85). Para as condições estudadas, obteve-se melhor adesão à dentina com a utilização do sistema adesivo de condicionamento total com três passos, sobretudo na região coronária / Abstract: This study aimed to evaluate lhe bond strengths between two total etching adhesive systems and (two and three steps) anda self-etching system to coronal and root canal dentin. The root canal of thirty human anterior teeth were endodontically instrumented and prepared with specific burs. Aestheti Plus #2 posts were duplicated in dual resin cement (Duo-link) and three groups (n=10) were formed, according to the adhesive sysfem used: 3 steps total etching adhesive system (3TE) - All-Bond 2 + resin cement post (rcp) + Duo-link (DI); 2 steps total etching adhesive system (2TE) - One-Step Plus + rcp + DI; sef-etching system (SE) Tyrian/One-Step Plus + rcp +DI. Following cementation, the teeth were cut transversally in eight sections (1,5mm), from the CEJ to 4mm above the canal apex. The sections were subjected to the push-out test in a universal testing machine (1mm.min-1). The data of bond strength were statistically analyzed with 2-way Anova of repeated measures (α<0.05), which showed that the interaction effect was significant. This meant that the relationship between the adhesives was not the same depending on the tooth region. Regarding the "adhesive factor'' the comparison of means with Tukey test (α<0.05) showed that 3TE (mean ± standard deviation: 5,22 ± 1,70) was statistically superior to 2TE (2,60 ± 1,74) and SE (1,68 ± 1,85). Under the conditions of the present study, the three step total etching system had the highest bond strengths to dentin, especially in the coronal region / Mestre
427

Resistência de união de cimentos resinosos, ao cisalhamento, variando o substrato e o material restaurador /

Ariki, Eurípedes Kaizo. January 2009 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Eduardo Galera da Silva / Banca: Marco Antonio Meloncini / Resumo: O objetivo deste estudo foi avaliar a resistência de união ao cisalhamento de três diferentes tipos de agentes cimentantes: auto-condicionante (Panavia F / P), convencional (RelyX ARC - R) e auto-adesivo (RelyX U100 - U), usando dois tipos de substratos (esmalte / E e dentina / D) e dois tipos de materiais restauradores (cerâmica - C e resina composta laboratorial - R). Foram utilizados cento e vinte incisivos bovinos incluídos em resina acrílica, de modo que uma parte da face vestibular ficasse exposta. Os dentes foram desgastados até se obter uma área lisa e plana, de aproximadamente de 25 mm2, em metade dos espécimes foi exposto esmalte, na outra metade dentina. Uma fita adesiva com um orifício no centro com 3 mm de diâmetro foi colada sobre estas áreas, delimitando a área a ser usada no teste. Foram confeccionados sessenta cilindros de cerâmica a base de dissilicato de lítio (IPS e.max) e sessenta cilindros de resina composta (SR Adoro) com dimensões de 3mm de diâmetro e 3mm de altura. Os cilindros foram cimentados aos substratos com os três tipos de cimento resinoso, formando doze grupos experimentais: G1(PEC); G2(PER); G3(PDC); G4(PDR); G5(REC), G6(RER); G7(RDC); G8(RDR): G9(UEC); G10(UER); G11(UDC) e G12(UDR). Após um período de uma semana, os corpos-de-prova foram levados à máquina de ensaios universais para a realização do teste de cisalhamento com velocidade de 0,5 mm/min. Os resultados (foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey em nível de 5% de significância. Verificou-se que o maior valor médio obtido foi do G5 (17,46 MPa) diferindo significativamente dos demais grupos, exceto do G1 (14,60 MPa). O G12 (1,03 MPa) apresentou o menor valor de resistência, não apresentando semelhança estatística com os outros grupos. A adesão em esmalte... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study was to evaluate the shear bond strength of three types of luting agents: self-etching (Panavia F, P), conventional (Rely X ARC, R) and self-adhesive (Rely X U100, U), using enamel (E) or dentin (D) as substrates and two types of restorative materials (ceramic, C and laboratorial composite, R). One hundred and twenty-five bovine incisors were embedded in acrylic resin leaving their bucal side exposed. The teeth were ground flat until a 5mm2 area was created. Half of the specimens had enamel exposed and the other half had dentin exposed. A piece of tape with a 3 mm hole was used to delimitate the bonding area. Sixty cylinders of ceramic (IPS E.max Press) and sixty of composite (SR Adoro), 3 mm in diameter and 3 mm in height, were confectioned. The cylinders were luted to the substrates, forming twelve groups: G1 (PEC); G2 (PER); G3 (PDC); G4 (PDR); G5 (REC), G6 (RER); G7 (RDC); G8(RDR): G9 (UEC); G10(UER); G11(UDC) and G12(UDR). After one week, the specimens were subjected to a shear test in a universal testing machine at a crosshead speed of 0,5 mm/min. The results were submitted to both the Anova and Tukey tests (p<0.05) for statistical analysis. It was observed that the mean of G5 (17,46 MPa) was significantly different from the other groups means, except for G1 (14,60 MPa). Statistically G12 (1,03) had the lowest bond strength differing from the other groups. Bondings between was ceramic and enamel determined the highest bond strength for all luting agents. Due to the low bond strength and the failures between cement and substrate, using the self-adhesive cement and laboratorial composite to make bonds is not advisable. / Mestre
428

Estudo de propriedades físicas de materiais adesivos ortodônticos /

Seixas, Michela Melissa Duarte. January 2005 (has links)
Orientador: João Carlos Silos Moraes / Banca: Fernanda de Carvalho Panzeri / Banca: Walter Katsumi Sakamoto / O avanço tecnológico trouxe grandes benefícios para a prática odontológica. Na ortodontia fixa, a colagem direta dos acessórios ortodônticos revolucionou a confecção de aparelhos ortodônticos. A introdução do condicionamento ácido do esmalte dental permitiu o desenvolvimento e aperfeiçoamento da fixação direta dos acessórios ortodônticos aos dentes, fazendo da colagem direta um procedimento clínico rotineiro. As resinas compostas passaram a ser largamente utilizadas como material de colagem devido às suas propriedades adesivas, e os bráquetes foram confeccionados de modo a apresentarem retenções mecânicas. Para a utilização de um material adesivo em ortodontia, é fundamental que o agente cimentante promova adesão suficiente entre o acessório ortodôntico e a superfície dentária. Outra característica importante é que o mesmo apresente um coeficiente de expansão térmica próximo ao do dente. O estudo da eficiência dos adesivos é sempre uma motivação e tem auxiliado os profissionais a obterem melhores resultados clínicos. Desta forma, este trabalho teve como objetivo avaliar a resistência ao cisalhamento com e sem termociclagem das resinas compostas Concise Ortodôntico e Fill Magic Ortodôntico, por meio de ensaios mecânicos, assim como estudar as diferenças de dilatação térmica entre os materiais do sistema dente-resina-bráquete, utilizando-se da técnica de extensometria. O Concise Ortodôntico apresentou os melhores resultados de resistência ao cisalhamento com e sem termociclagem e um menor coeficiente de expansão térmica comparados aos respectivos resultados de cisalhamento e expansão térmica da resina Fill Magic Ortodôntico. O material utilizado na confecção do bráquete ortodôntico apresentou um coeficiente de expansão térmica mais próximo ao do esmalte dental. Por outro lado, apresentou coeficiente... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The technological progress brought great benefits in the practice of dentistry. In the orthodontics, the direct bonding of the orthodontic attachments revolutionized the making of the orthodontic appliances. The introduction of the acid etching technique allowed the development and improvement of the direct fixation of the brackets to the teeth, becoming the direct bonding a routine clinical procedure. The composites are used broadly as bonding material due to their adhesive properties and the brackets present good mechanical retention. The material adhesive to be used has to promote enough adhesion between the bracket and the dental surface. Besides, it is important that it presents a coefficient of thermal expansion similar to the one of the tooth. The study of the efficiency of the adhesives systems is always a motivation and it aids the professionals to obtain better clinical results. Therefore, this work had as objective to evaluate the shear bond strength with and without thermoclycling of the composed Orthodontic Concise and Fill Magic, through mechanical tests, as well as to study the thermal expansion of the materials of the tooth-resin-bracket system by extensometry technique. The Concise resin presented the better results of shear bond strength with and without thermoclycling and a smaller coefficient of thermal expansion when compared to the respective results for Fill Magic resin. The bracket's material presented a coefficient of thermal expansion similar to the dental enamel. On the other hand, its coefficient is smaller than those of the two evaluated resins (twice smaller than to of Concise and three times to of Fill Magic). / Mestre
429

Avaliação da biocompatibilidade de dois adesivos dentinários pelo estudo das reações teciduais em conjuntivo de ratos /

Gomes, Ana Paula Martins. January 1994 (has links)
Orientador: Jaime Freitas Ribeiro / Banca: Carlos Eduardo Aun / Banca: Maria Amélia Maxímo de Araújo / Resumo: A biocompatibilidade de dois adesivos dentinários (Scotchbond MultiPurpose- 3M e Optibond Multi-Use - Kerr) foi avaliada por meio de implantes em tecido conjuntivo subcutâneo de ratos. Os implantes foram realizados, utilizando-se tubos de polietileno preenchidos com os respectivos adesivos e inseridos em lojas cirúrgicas preparadas no dorso dos animais, os quais foram sacrificados nos periodos de observação de 14, 30, 60 e 84 dias. Os tecidos circunjacentes aos implantes foram removidos, incluídos em parafina e corados com hematoxilina e eosina para análise em microscopia óptica. Os resultados mostraram moderado a discreto infiltrado inflamatório nos períodos iniciais de observação (14 e 30 dias) e reparação da área nos períodos posteriores (60 e 84 dias), com formação de cápsula fibrosa envolvendo todos os implantes. Os resultados obtidos nos permitiram concluir que: a) os dois adesivos dentinários são biologicamente aceitáveis quando colocados em contato com o tecido conjuntivo subcutâneo de ratos; b) houve reação moderada do tecido conjuntivo subcutâneo de ratos aos dois adesivos dentinários no período de observação de 14 dias, a qual persistiu com o adesivo Optibond MultiUse-light cure- (Kerr) aos 30 dias; c) as reações teciduais provocadas pelos dois adesivos nos períodos de observação de 60 e 84 dias foram semelhantes e biologicamente aceitáveis / Abstract: The biocompatibility of two dentin adhesives (Scotchbond MultiPurpose- 3M and Optibond Multi-Use - Kerr) was evaluated in rats subcutaneous connective tissue implants. Polyethylene tubes filled with the adhesives were surgically implanted into the dorsal subcutaneous tissues of rats. The tubes were left implanted for periods of 14, 30, 60 and 84 days, following wich the animais were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microscopy. After 14 and 30 days the tubes were surrounded by a mild to moderate inflammatory infiltration. After 60 and 84 days microscopic examination revealed the formation of a connective tissue capsule around each tube. The microscopic examination of the biopsy specimens allowed to conclude that: a) both dentin adhesives are considered biologically acceptable when placed in contact with rats subcutaneous connective tissue; b) in the observation period of 30 days there were moderate tissue reaction to the Optibond Multi-Use -light cure- (Kerr); c) after 60 and 84 days the use of both dentine adhesives did not interfere in the healing of the surrounding connective tissue / Mestre
430

Adesivos multi-uso-avaliação da resistência adesiva a dentina frente a teste de cisalhamento, estereomicroscopia e microscopia eletrônica de varredura /

Gonçalves, Sérgio Eduardo de Paiva. January 1994 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: Dan Mihail Fichman / Banca: Rogerio Lacaz Neto / Resumo: Adesão tem sido a meta das pesquisas Odontológicas nas últimas décadas. Para determinar se os mais recentes sistemas adesivos denominados como MULTI-USO poderiam ser utilizados associados a diferentes marcas comerciais de resina composta, em dentina, foram realizados testes de resistência ao cisalhamento. Setenta e dois corpos de prova foram confeccionados utilizando-se dentes pré-molares humanos íntegros, embutidos em resina acrílica, expondo-se a dentina por tratamento com lixas d'água de granulações 180, 400 e 600. Os corpos de prova foram divididos em três grupos: Grupo 1 Scotchbond Multi-Purpose (3M), grupo 2 - Optibond Light Cure (Kerr) e grupo 3 - Optibond Dual Cure (Kerr). Todos os grupos foram subdivididos em sub-grupos de 8 dentes, nos quais foram inseridas as resinas compostas: a-Z1 00 (3M do Brasil), bPrisma APH (Dentsply) e c- Herculite XRV(Kerr). Os corpos de prova foram submetidos à ciclagem térmica e após 24 horas de armazenamento em água destilada 370C, aos testes de resistência ao cisalhamento em máquina lnstron 4301 seguidos de análise em estereomicroscópio Technivai-Carl Zeiss de aumento para avaliar o tipo de fratura e, análise em microscopia eletrônica de varredura (M.E.V.). A aplicação do modelo estatístico de análise de variância permitiu a constatação de que o fator Adesivo apresentou um valor significante (p<0,05) independente do fator Resina, tendo o adesivo Optibond Light Cure propiciado a maior resistência média ao cisalhamento (15,446 MPa), seguido do Scotchbond Multi-Purpose (13,340 MPa) e do Optibond Dual Cure (1 0,019 MPa). A interaçâo Adesivo x Resina apresentou um valor estatisticamente significante (p<0,05), onde os melhores resultados foram obtidos entre as resinas Z100 e Herculite XRV com o adesivo Optibond Light Cure, e entre a Resina APH com o adesivo Scotchbond Multi-Purpose. Concluímos que o adesivo Optibond... / Abstract: Recent bonding systems have been advocated as "multi-purpose bonding agents". The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose / Mestre

Page generated in 0.085 seconds