• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 907
  • 81
  • 78
  • 78
  • 78
  • 68
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 922
  • 922
  • 454
  • 392
  • 234
  • 208
  • 160
  • 149
  • 100
  • 97
  • 81
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
411

Avaliação in vitro da microinfiltração marginal em restaurações indiretas inlay de porcelana. Efeito de diferentes agentes cimentantes

Pinto, Xerxes de Campos [UNESP] 26 October 1999 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-10-26Bitstream added on 2014-06-13T20:12:02Z : No. of bitstreams: 1 pinto_xc_me_arafo.pdf: 425515 bytes, checksum: 918e193f0478baacea9e3c1230ddf157 (MD5) / O objetivo deste estudo foi de avaliar in vitro a microinfiltração marginal, somente nas paredes em dentina, de cavidades restauradas pela técnica indireta inlay de porcelana e cimentadas com cimentos resinosos do tipo Auto-Polimerizável, Dual e resinas Flow fotopolimerizável. Para a realização desta pesquisa, foram utilizados quarenta dentes terceiros molares de humanos recém-extraídos e isentos de cárie, os quais receberam preparos cavitários do tipo classe II padronizados. Os dentes foram restaurados com inlay de porcelana (Ceramco II) e cimentadas com: Panavia, Dual Cement, Enforce e Resina Flow (Renamel). Foi realizada a ciclagem térmica e os dentes foram colocados em uma solução evidenciadora de nitrato de prata a 50% e depois seccionados. A análise da microinfiltração marginal foi nas paredes localizadas abaixo 1mm da junção esmalte-cemento portanto somente em dentina. Concluiu-se que todos os materiais estudados apresentaram microinfiltração, e que houve diferença significante entre os materiais Dual Cement e Resina Flow (Renamel), onde o material Dual Cement apresentou a maior infiltração média e a resina Flow (Renamel) a menor. Os demais materiais comparados dois a dois tiveram comportamento semelhantes. Por ter obtido, um material não específico para cimentação, o melhor resultado, necessitamos de mais pesquisas sobre o assunto para podermos entender melhor os resultados. / The purpose of this in vitro study was to evaluate the microleakage around dentin cavosurface margins of cavities restored with porcelain indirect technique and bonded with a dual cure luting composite chemical cure resin and flow resins. Standardized preparations were cut in forty extracted human third molars. The teeth were restored with porcelain inlay (Ceramco II) and luted with: Panavia, Dual Cement, Enforce and Resina Flow (Renamel). The specimens were thermocycled and the microleakage was evaluated by use of 50% Silver nitrate. The depth of leakage was measured microscopically after the teeth were sectioned of dentin margins. Data analysis indicated microleakage of dentin margins in all groups. In dentin margins showed significant difference comparison between material Dual Cement and Flow resin (Renamel), the Dual Cement showed greater significant microleakage. Microleakage has ocurred ina a higher degree with Flow Resin (Renamel). In offscreen comparison between other materials, there was not significant difference in microleakage. The best effect of luting agents was a non specific material to cimentation. More research has required to understand the our results.
412

Avaliação da citotoxicidade de agentes clareadores dentais de uso profissional variando o mecanismo de ativação, fibroblastos de polpa humana

Nakáo, Mariana Pretti [UNESP] 15 May 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-05-15Bitstream added on 2014-06-13T20:31:52Z : No. of bitstreams: 1 nakao_mp_me_sjc.pdf: 575104 bytes, checksum: 3e65e53ea5787201a2552f5be4884109 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A proposta deste estudo foi avaliar a citotoxicidade do peróxido de hidrogênio (PH) liberado por dois géis clareadores, utilizados para a técnica de consultório, sobre cultura de fibroblastos de polpa humana (FP5). As células foram cultivadas em DMEM. Foram utilizadas células entre a quinta e décima passagens. Colocou-se sobre as células meios de cultura condicionados de acordo com os grupos de estudo (n=4): G1- PH 35% sem fotoativação; G2- PH 35% ativado por luz alógena; G3- PH 35% ativado por diodo emissor de luz (LED); G4- PH 38% sem fotoativação; G5- PH 38% ativado por luz alógena; G6- PH 38% ativado por LED. Uma curva padrão de viabilidade e crescimento celular foi obtida a partir de células que não receberam tratamento (controle). O ensaio com MTT ocorreu após 0, 24 e 48 horas, para avaliar a viabilidade e crescimento celular. Paralelamente, mediu-se colorimetricamente a quantidade de PH liberado nas condições experimentais, utilizando-se solução tampão de acetato no lugar do meio de cultura. Os dados foram analisados através do teste de Dunnet, ANOVA e teste de Tukey. Todos os grupos apresentaram diferença significativa em relação ao controle. O PH 38% apresentou maior citotoxicidade e quantidade de peróxido de hidrogênio liberada que o PH 35% nas condições experimentais. A ativação por luz alógena ocasinou maior citotoxicidade e maior quantidade de PH liberado, e a ativação com LED foi estatisticamente semelhante à ausência de ativação. A avaliação após 48 horas apresentou diferença estatística das avaliações de 0 e 24 horas. Concluiu-se que: a citotoxicidade foi proporcional à concentração do agente clareador; a fotoativação com luz alógena aumentou a liberação de peróxido de hidrogênio, e o metabolismo celular foi menor imediatamente após o contato com o meio condicionado, aumentando após 24 e/ ou48 horas. / The propose of this study was to evaluate hydrogen peroxide (HP) cytotoxicity, from two in office bleaching agents, on human pulp fibroblasts (FP5) culture. The cells were cultured in DMEM. Only cells between fifith and tenth passages were used. Each well of culture plate, corresponding to experimental groups, received conditioned middle according to the experimental groups: G1- HP 35% without light activation; G2- HP 35% activated by halogen light; G3- HP 35% activated by LED; G4- HP 38% without light activation; G5- HP 38% activated by halogen light; G6- HP 38% activated by LED. Viability and growth standard curve was obtained from an untreated group and was used as control. MTT assay was performed in four wells for each group, in periods of 0, 24 or 48 hours, to measure cells viability and growth. Hydrogen peroxide leased in experimental conditions was also measured, using acetate buffer instead culture middle. Results were analyzed by Dunnet test, variance analysis and Tukey test. All experimental groups showed difference from control. The cytotoxicity and quantity of hydrogen peroxide was higher with 38% hydrogen peroxide (Opalescence Xtra Boost) than with 35% hydrogen peroxide (Whiteness HP). Activation by halogen light caused smaller cell growth and viability but higher hydrogen peroxide amount, and LED was statically similar to the group without activation. 48 hours evaluation was different then 0 and 24 hour evaluations. Conclusions: cytotoxicity was proportional to quantity of hydrogen peroxide leased; halogen light activation increased the leased hydrogen peroxide, and cell viability was lower immediately after contact with conditioned middle, increasing after 24 and/or 48 hours.
413

Influência do preparo biomecânico na microdureza e selamento marginal do MTA e do polímero derivado da mamona em perfurações radiculares simuladas

Fonseca, Manuela Bafini [UNESP] 30 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-30Bitstream added on 2014-06-13T19:31:22Z : No. of bitstreams: 1 fonseca_mb_me_sjc.pdf: 399685 bytes, checksum: 9bb763e92887dff625815a9d52e9f57f (MD5) / Neste estudo foram utilizados 96 dentes incisivos laterais bovinos que foram padronizados por meio de perfurações circulares com 2mm de diâmetro na face vestibular. As raízes foram divididas em 4 grupos de acordo com o material utilizado: G1-mineral trióxido agregado (MTA) sem proteção, G2- MTA protegido com cianoacrilato (SB), G3- MTA protegido com cimento de ionômero de vidro, G4- cimento derivado do polímero da mamona (CPM) sem proteção. Em seguida os canais foram preparados pela técnica seriada. As raízes foram seccionadas no sentido longitudinal. Catorze hemisecções foram utilizadas para análise de microinfiltração e 10 para análise de microdureza, para cada grupo. Para a análise de microinfiltração, as hemisecções foram impermeabilizadas e colocadas em solução tamponada de Rodamina 2% por 24 horas. No teste de microdureza as hemisecções foram incluídas em resina acrílica e desgastadas na face vestibular. Os dados da microinfiltração e microdureza foram avaliados através da análise estatística em nível de significância de 5%. Pôde-se observar que apesar do CPM ter o menor índice de infiltração (0.652 mm), observando-se as médias correspondentes (1.143 mm -MTA, 1.302 mm -SB, 1.029 mm - CIV) estatisticamente não houve diferença significante entre os grupos. No teste de microdureza pôde-se observar que todos os grupos com MTA (94,69HV -MTA, 92,25 HV - SB, 97,68 HV -CIV) demonstraram maior dureza em relação ao grupo do CPM (8,477 HV) com diferenças estatisticamente significante. Pode-se concluir que não houve injúria dos materiais quando submetidos aos agentes químicos e mecânicos. A realização das proteções do cimento de MTA não proporcionou melhoria nos resultados de microdureza. Todos os materiais mantiveram médias baixas de infiltração demonstrando serem eficientes como materiais seladores. O CPM se mostrou um material com boas propriedades seladoras, porém apresentou baixa dureza. / In this study 96 bovine lateral incisor teeth were used that were standardized through perforations with 2mm of diameter in the buccal surface. The roots were divided into 4 groups according to the used material: G1 - mineral trioxide aggregate (MTA) without sealing, G2 - MTA sealed with cianoacrilate (Super Bonder, Henkel, São Paulo, Brazil) - SB, G3 - MTA sealed with glass ionomer cement (Vidrion R, S.S.White, Rio de Janeiro, Brazil) - CIV, G4 - castor oil bean cement (CPM) without sealing. Afterwards the roots were prepared by stepback technique. The roots were split up in the longitudinal direction. Fourteen roots were used in microleakage analysis and ten in microhardness test of each group. For the microleakage the specimens were waterproof and put in buffer solution of 2% Rodhamina by 24 hours. In the microhardness test the specimens were included in acrylic resin and consumed in the buccal direction. The data of the microleakage and microhardness tests were appraised through the statistical analysis (level of significance 5%). It was observed that in spite of CPM having the smallest infiltration index (0.652 mm), was observed the corresponding averages (1.143 mm - MTA, 1.302 mm - SB, 1.029 mm - CIV) however there was no statistically significant difference among the groups. In the microhardness test the difference was analyzed among the materials. And all of the groups with MTA (94,69HV - MTA, 92,25 HV - SB, 97,68 HV - CIV) demonstrated higher hardness comparing to the CPM group (8,477 HV). It was concluded that there was no harmful of the materials when submitted to the chemical and mechanical agents. The performance of the sealing of the MTA cement did not provide improvement in the microhardness results. All the materials maintained low averages of infiltration. All materials demonstrated to be efficient and CPM was shown as a material with good sealing properties on the other hand showed low hardness.
414

Avaliação dos sistemas MTwo Retratamento e ProTaper Universal Retratamento na remoção de guta-percha e novos cimentos endodônticos dos canais radiculares

Moreira, Camila Said [UNESP] 12 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-12Bitstream added on 2014-06-13T20:12:44Z : No. of bitstreams: 1 moreira_cs_me_sjc.pdf: 548037 bytes, checksum: 08067892942db60d34c48b98e0615b5c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar, in vitro, a eficácia dos sistemas MTwo Retratamento e ProTaper Universal Retratamento na remoção de diferentes cimentos endodônticos associados à guta-perchas das paredes dos canais radiculares. Sessenta dentes unirradiculares humanos extraídos foram instrumentados com limas rotatórias e divididos de forma aleatória em 3 grupos (n=20). Os canais radiculares foram obturados com guta-percha associada aos cimentos AHPlus Jet®, MTA Fillapex® e RoekoSeal Automix®. Os espécimes foram radiografados após a obturação para conferência do preenchimento radicular. Após 30 dias mantidos em estufa a 37ºC e umidade relativa em 100%, os espécimes foram desobturados seguindo duas diferentes técnicas de retratamento: com limas rotatórias MTwo Retratamento® e com limas rotatórias ProTaper Universal Retratamento®. Através de películas tomográficas feitas antes e após a desobturação, pelo método do feixe cônico, os espécimes foram avaliados quanto à área total de material obturador e quanto à quantidade de material obturador remanescente nos canais radiculares após a desobturação. Durante o retratamento, o tempo de desobturação foi cronometrado. Os dados relativos à quantidade de material remanescente e tempo de desobturação foram submetidos à análise estatística utilizando ANOVA e teste de Tukey com nível de significância de 5%. Nenhum sistema rotatório foi capaz de remover todo o material obturador dos canais radiculares. Não houve diferenças significantes entre os sistemas rotatórios, porém ambos se mostraram rápidos e eficientes. O cimento AHPlus Jet foi o mais difícil de ser removido e foi o cimento que deixou maior quantidade de material obturador remanescente nas paredes radiculares / The purpose of this study was to evaluate, in vitro, the efficacy of MTwo Retreatment and ProTaper Universal Retreatment Systems in the removal of filling material from root canals. Sixty single-rooted human teeth were prepared by using nickel-titanium rotary files and randomly allocated into 3 groups (n=20). The root canals were filled with gutta-percha and AHPlus Jet®, MTA Fillapex® and RoekoSeal Automix®. After 30-day storage at 37oC and 100% humidity, the root fillings were removed using MTwo Retreatment or ProTaper Universal Retreatment files. The specimens were analyzed through tomographic images after root canal filling and after retreatment. The images were digitalized and analyzed by software Image Tool for Windows (version 3.0) for evaluation of remaining filling material. During the retreatment, time required for endodontic filling removal was analyzed. Data were submitted to statistical analysis by ANOVA and Tukey tests at the significance of 5%. None of the rotarysystems was able to remove the entire root canal filling material. There were no significant differences between the rotary systems, but both proved to be fast and efficient. The AHPlus Jet sealer was the most difficult to be removed and it was the sealer that left more remaining filling material on the walls root
415

Avaliação clínica de restaurações classe v restauradas com a técnica direta e semidireta

Rodrigues, Patrícia Silva Hamester January 2013 (has links)
Made available in DSpace on 2015-06-16T02:06:47Z (GMT). No. of bitstreams: 1 000468076-Texto+Completo-0.pdf: 1121444 bytes, checksum: 65fc7c05be36d73bf2d8b7f5853d6a61 (MD5) Previous issue date: 2013 / Objective: The objective of this study was to evaluate in 6 months Class V restorations clinically with composite resin ( Glacier ) and glass ionomer cement ( Riva selfcure ) with the direct technique and restorations semidirect technique, cemented with self-adhesive resin cement ( SeT ) and total etching cement ( RelyX ARC ).Methods: One hundred and twenty restorations were performed by a single operator in 30 patients. Each patient received a composite resin restoration ( RGLA ), glass ionomer cement ( RVA ), ceromer cemented with RelyX ARC ( RARC ), and cemented with SeT (RSET ). After 6 months, the evaluation was performed using the USPHS criteria for the presence of restoration, marginal integrity, color and presence of secondary caries .Results: The results were obtained through statistical analysis of generalized linear mixed model and showed that only the restorations cemented with SeT were statistical difference, with significant loss of restorations. No patient had secondary caries after 6 months of evaluation. The marginal integrity and color were not significantly different between groups .Conclusion: We conclude that restorations cement with self-adhesive SeT failed. Thus the direct restorations had a better behavior than the semidirect restorations. However semidirects restorations cemented with Adper Single Bond 2 + RelyX ARC and total etching presented along with the RVA group the highest predictive average. / Objetivo: O Objetivo deste trabalho foi avaliar clinicamente no período de 6 meses restaurações classe V em resina composta (Glacier) e cimento de ionômero de vidro (Riva selfcure) pela técnica direta, e restaurações com cerômero pela técnica semidireta cimentadas com cimento resinoso autoadesivo (SeT) e com condicionamento total (RelyX ARC).Material e método: Cento e vinte restaurações foram realizadas por um único operador em 30 pacientes. Cada paciente recebeu uma restauração de resina composta (RGLA), Cimento de ionômero de vidro (RVA), cerômero cimentada com RelyX ARC (RARC), e cerômero cimentada com SeT (RSET). Após 6 meses as avaliações foram realizadas através dos critérios do USPHS modificado quanto à presença da restauração, integridade marginal, descoloração marginal e presença de cárie secundária. Resultados: Os resultados foram obtidos através da análise estatística de modelo linear misto generalizado e mostraram que somente as restaurações de cerômero cimentadas com SeT apresentaram diferença estatística, com perda significativa das restaurações. Nenhum paciente apresentou cárie secundária após os 6 meses de avaliação. A integridade marginal e descoloração marginal não apresentaram diferença estatística entre os grupos. Cconclusão: Concluímos que as restaurações realizadas com cimento autoadesivo SeT falharam. Desta forma as restaurações diretas tiveram um comportamento melhor que as restaurações semidiretas. Todavia as restaurações semidiretas cimentadas com Adper Single Bond 2 + RelyX ARC e condicionamento ácido total apresentaram junto com o grupo RVA a maior média preditiva.
416

Efeito biológico do Biodentine® e do MTA sobre exposição de tecido pulpar e periodontal da furca: estudo em ratos / Biological Effect Of Biodentine® And Mta On Rats´ Dental Pulp And Furcal Periodontal Tissues

Reis, Magda de Sousa January 2015 (has links)
Made available in DSpace on 2016-02-13T01:07:16Z (GMT). No. of bitstreams: 1 000477246-Texto+Completo-0.pdf: 2952696 bytes, checksum: 9a8e4368b83491c5888a26990b0c9ddc (MD5) Previous issue date: 2015 / The aim of this study was to evaluate dental pulp and furcal periodontal tissue responses to mineral trioxide aggregate (MTA) and to a calcium silicate-based material (Biodentine™). The lower first molars in hundred forty (140) male Wistar rats were divided into groups according to the experimental site and period (14 and 21 days) testing two materials (n=8 per group/period in pulpotomy and n=6 per group/period in furcal perforation). Groups capped and sealed with MTA or Biodentine™ were restored with silver amalgam; in an additional test group, teeth were capped and restored with Biodentine™. Teeth capped with gutta-percha and restored with silver amalgam served as a positive control and untouched teeth were negative control. Histological evaluation of pulp responses and macroscopic examination of coronal sealing were performed. Inflammation extension and intensity, degenerative events and formation of mineralized tissue barrier were assessed. In the experiment of furcal perforations, inflammation extension and intensity, bone resorption and cement formation were assessed histologically. All results underwent ANOVA and Tukey post hoc tests (p<. 05). In pulpotomy, Biodentine™ and MTA presented satisfactory results, which were characterized by a mild inflammatory response (p<. 0001) and more pronounced formation of mineralized barrier (p<. 0001) compared to teeth capped with gutta-percha. When used as a restorative material, Biodentine™ kept coronal sealing in only 37. 5% of the samples. As to furcal perforations, Biodentine™ and MTA presented satisfactory results, which were characterized by a milder inflammatory response compared to the control, regardless of the material used for coronal sealing and of the experimental period evaluated (p<. 0001). All test groups showed less bone resorption than the positive control after 21 days (p<. 05), being this difference more pronounced in teeth restored with silver amalgam. Cement repair occurred in 30% of MTA and Biodentine™ samples, and was not detected in any specimen of the positive control group. In conclusion, Biodentine™ and MTA promoted similar responses when used to pulp capping and furcal perforation sealing. On the other hand, the use of Biodentine™ as temporary restorative material did not promote efficient coronal sealing. Although further investigations are required, Biodentine™ can be considered an alternative for pulpotomy and furcal perfuration. / O objetivo deste estudo foi comparar a resposta tecidual, após pulpotomias e perfurações de furca, utilizando agregado trióxido de mineral (MTA) e o material à base de silicato tricálcico (Biodentine®). Os primeiros molares inferiores de 140 ratos Wistar machos foram utilizados em dois tempos (14 e 21 dias) e divididos em grupos conforme o experimento e materiais utilizados (pulpotomia n=8 e perfuração de furca n=6). Nos dois experimentos, grupos capeados e selados com MTA e Biodentine® foram restaurados com amálgama de prata; um grupo adicional utilizou somente Biodentine® e o controle positivo recebeu guta-percha e restauração de amálgama; dentes intactos serviram de controle negativo. No experimento de pulpotomias, realizou-se exame macroscópico e radiográfico do selamento coronário e exame histológico dos eventos inflamatórios (intensidade e extensão), degenerativos e de formação de barreira mineralizada. No experimento de perfurações de furca, foram avaliados histologicamente os eventos inflamatórios (intensidade e extensão), de reabsorção óssea e reparo de cemento. Os dados foram comparados através da análise de variância (ANOVA) e posthoc de Tukey (p<. 05). Nas pulpotomias, o Biodentine® e MTA apresentaram resultados satisfatórios, com menor resposta inflamatória (p<. 0001) e pronunciada formação de barreira mineralizada (p<. 0001) comparada aos dentes do controle positivo. O Biodentine®, utilizado como restauração, manteve o selamento coronário em apenas 37. 5% das amostras. Nas perfurações de furca, o Biodentine e MTA apresentaram resultados satisfatórios, caracterizados por uma resposta inflamatória mais suave em comparação ao controle positivo, independentemente do material utilizado para o selamento coronário e período experimental avaliado (p<. 0001). Todos os grupos testes mostraram menor reabsorção óssea do que o controle positivo após 21 dias (p<. 05), sendo esta diferença mais acentuada em dentes restaurados com amálgama de prata. A reparação de cemento ocorreu em 30% das amostras de MTA e Biodentine, e não foi detectada em qualquer amostra do grupo do controle positivo. Concluiu-se que houve respostas similares após o uso de Biodentine® e MTA no capeamento da polpa exposta e selamento de perfurações de furca. Por outro lado, o uso do Biodentine® como material restaurador provisório não promoveu selamento coronário eficiente. Embora sejam necessárias novas investigações, o Biodentine deve ser considerado como uma alternativa frente aos tratamentos propostos.
417

Efeito da lubrificação sobre a pré-carga e o torque de remoção de parafusos odontológicos de conexão submetidos a ciclos de aperto e desaperto

Kunz, Tiago January 2015 (has links)
Made available in DSpace on 2016-02-12T01:05:11Z (GMT). No. of bitstreams: 1 000477181-Texto+Completo-0.pdf: 2813092 bytes, checksum: 4a31e9fa6f6b00754e7f702733f5c592 (MD5) Previous issue date: 2015 / Screw loosening is often a complication reported in prosthetic implants. The torque develops a compressive clamping force between parts called preload, which holds the components together and the reducing of friction between the surfaces has been shown to increase its value. Dry lubricants, also called coatings have been used and the results are satisfactory, but the use of liquid lubricants is still little explored, which is the aim of this study. For this, 14 titanium screws and 14 screws with (Diamond-Like Carbon) DLC coating were randomly assigned to four groups (Titanium; DLC, Titanium with oil, and DLC with oil) and subjected to five cycles of tightening and loosening. The screws of groups Titanium with oil and DLC with oil were lubricated with castor oil. The preload was measured by a preload gauge cell, especially developed for the study. The results of preloads and average removal torques for torques of 20 and 32Ncm at 2 different times were analyzed: after the first grip and after five consecutive grips. At the end of the analysis, the thread pitches were measured to rule out plastic deformation. The Group DLC had higher pre-load values at all time points, but it was only significant after the sequence grips with 32 Ncm, and in the absence of oil. It was concluded, therefore, that the castor oil lubrication was not able to significantly increase the preload values or removal torque. / O afrouxamento do parafuso é uma complicação frequentemente reportada em próteses sobre implantes. O torque desenvolve uma força compressiva de aperto entre as partes chamada pré-carga, que mantém os componentes unidos, e a redução do atrito entre as superfícies tem demonstrado aumentar o seu valor. Lubrificantes secos, também chamados de recobrimentos, têm sido utilizados e os resultados são satisfatórios, contudo o emprego de lubrificantes líquidos ainda é pouco explorado, sendo o objetivo deste estudo. Para isso, 14 parafusos de titânio e 14 parafusos com recobrimento de Diamond-Like Carbon (DLC) foram aleatoriamente alocados em quatro grupos (Titânio; DLC; Titânio com Óleo; e DLC com Óleo) e submetidos a cinco ciclos de aperto e desaperto. Os parafusos dos grupos Titânio com Óleo e DLC com Óleo foram lubrificados com óleo de mamona.A pré-carga foi mensurada por meio de uma célula aferidora de pré-carga, desenvolvida especialmente para o estudo. Foram analisados os resultados das pré-cargas e torques de remoção médios para os torques de 20 e 32 Ncm em dois momentos distintos: após o primeiro aperto e depois de cinco apertos consecutivos. Ao fim das análises, os passos de roscas foram mensurados para descartar deformações plásticas. O Grupo DLC apresentou maiores valores de pré-carga em todos os momentos de avaliação, contudo ele só foi significativo após a sequência de apertos com 32 Ncm, e na ausência do óleo. Concluiu-se, portanto, que a lubrificação com óleo de mamona não foi capaz de aumentar significativamente os valores da pré-carga ou do torque de remoção.
418

Análise da adaptação marginal de facetas laminadas confeccionadas pela tecnologia CAD/CAM: estudo in vitro

Pereira, Duziene Denardini January 2016 (has links)
Made available in DSpace on 2016-04-08T03:07:20Z (GMT). No. of bitstreams: 1 000477935-Texto+Parcial-0.pdf: 597 bytes, checksum: 10775e484d6bf1f1e42f8cc96adb6e1c (MD5) Previous issue date: 2016 / The Computer-aided design/Computer-aided manufacturing (CAD/CAM) system has been widely used for the production of prosthetic restorations. The objective of this study was to analyze the marginal adaptation of veneers made by this technology using different restorative materials. To this they are milled 25 samples of laminates and divided into each following materials tested. Group 1: E-max (lithium disilicate); Group 2: Empress (leucite); Group 3: Lava Ultimate (ceromer); Group 4: Suprinity (lithium disilicate reinforced with zirconium oxide); and Group 5: Vita Mark II (feldspatic). The veneers were cemented in their respective preparations and then we obtained imagens in digital microscopy (Caltex Systems VZM-2003D Digital – Video Mensurement Inspection) with 7. 5X increase. They have been transferred to the software ImageTool for the analysis of marginal gap (mesial and distal; and the third cervical, middle and incisal). It was observed that the largest gap value found in the cervical region of the restoration was made with the Vita Mark II ceramic, and even though there was no statistically significant difference between the ceramic studied (p=0,2 mesial and p=0,4 distal), the incisal third had higher mismatches. It can be concluded that all the ceramics showed good marginal adaptation in the cervical region. / O sistema Computer-aided design/Computer-aided manufacturing (CAD/CAM) tem sido amplamente utilizado para a produção de restaurações protéticas. O objetivo deste trabalho foi analisar a adaptação marginal de facetas laminadas confeccionadas por esta tecnologia utilizando diferentes materiais restauradores. Para tal, foram fresadas 25 amostras de laminados e divididas em cada um dos seguintes materiais testados: Grupo 1: E-max (Dissilicato de lítio); Grupo 2: Empress (Leucita); Grupo 3: Lava Ultimate (Cerômero); Grupo 4: Suprinity (Dissilicato de lítio reforçado com óxido de zircônio) e Grupo 5: Vita Mark II (Feldspática). As facetas laminadas foram cimentadas nos seus respectivos preparos e, então, foram obtidas imagens em microscopia digital (Caltex Systems VZM-2003D Digital – Video Mensurement Inspection) com 7. 5X de aumento. As mesmas foram transferidas para o programa ImageTool para a análise do gap marginal (faces mesial e distal; nos terços cervical, médio e incisal). Observou-se que o maior valor de gap encontrado na região cervical foi da restauração confeccionada com a cerâmica Vita Mark II e, mesmo não havendo diferença estatisticamente significante entre as cerâmicas estudadas (p=0,2 mesial e p=0,4 distal), o terço incisal obteve maiores desadaptações. Pode-se concluir que todas as cerâmicas apresentaram boa adaptação marginal na região cervical.
419

Comparação in vitro da citotoxidade dos anéis ortodônticos com e sem soldagem à prata em diferentes linhagens celulares

Jacoby, Letícia Spinelli January 2016 (has links)
Made available in DSpace on 2016-05-07T12:04:32Z (GMT). No. of bitstreams: 1 000478491-Texto+Parcial-0.pdf: 409701 bytes, checksum: ece1c9e62d9b0d680c9b4a7d64a27079 (MD5) Previous issue date: 2016 / Introduction: The aims of this study were to assess the in vitro cytotoxicity of orthodontic bands, with and without silver solder, and to compare the viability of the HaCaT, HGF, MRC-5, and Vero cell lines, when exposed to orthodontic band extracts. Material and Methods: An MTT assay was performed on the extracts of the tested materials. The culture medium alone was used as a negative control and copper strip extracts were used as a positive control. Results: A one-way Analysis of Variance (ANOVA) showed a difference between all of the groups in all of the cell lines and Tukey’s post-hoc test revealed no significant differences between the stainless steel orthodontic bands and the negative control group. There was a significant difference between the negative control group and the stainless steel orthodontic bands with silver solder joints in the HaCaT and MRC-5 cell lines. A great variability in the percentages of cell viability was observed. According to these results, the stainless steel orthodontic bands did not induce cytotoxic effects on any of the cell lines. When associated with silver solder, the orthodontic bands decreased the cell viability in the HaCaT, HGF, MRC-5, and Vero cell lines, but there was only a statistical significance in the HaCaT and MRC-5 cell lines. Conclusions: More than one type of cell line must be tested in a cytotoxicity assay due to the outcome variability from one cell line to another. / Introdução: Os objetivos deste estudo foram avaliar, in vitro, a citotoxicidade dos anéis ortodônticos com e sem soldagem à prata e comparar a viabilidade celular nas linhagens FGH, HaCaT, MRC-5 e Vero após a exposição aos extratos dos anéis ortodônticos. Materiais e Métodos: Foi realizado o ensaio de redução de MTT após a exposição das culturas celulares aos extratos dos materiais testados. Foram utilizados como controles negativo e positivo, respectivamente, meio de cultura DMEM e extratos de tira de cobre. Resultados: A análise de variância de uma via (ANOVA) mostrou que houve diferença estatisticamente significativa entre os grupos em todas as linhagens avaliadas. O teste de comparações múltiplas de Tukey detectou ausência de diferença significativa entre os grupos controle negativo e anéis ortodônticos de aço inoxidável. Houve diferença estatisticamente significativa entre os grupos controle negativo e anéis ortodônticos de aço inoxidável com soldagem à prata nas linhagens celulares HaCaT e MRC-5. Observou-se grande variabilidade nas percentagens de viabilidade celular entre as linhagens. Conclusões: Ao avaliar a citotoxicidade de anéis ortodônticos com e sem soldagem à prata, existe variabilidade nos resultados quando linhagens diferentes são comparadas. Anéis ortodônticos de aço inoxidável não induziram efeitos citotóxicos em nenhuma das linhagens testadas. Quando associados à solda de prata, os extratos dos anéis ortodônticos reduziram a viabilidade celular nas linhagens FGH, HaCaT, MRC-5 e Vero, embora essa redução tenha ocorrido de forma estatisticamente significativa apenas nas linhagens HaCaT e MRC-5.
420

Estudo da biocompatibilidade da liga Ti-6AI-7Nb e titânio de grau 2 em tíbia de coelhos /

Momose, Dalton Reis. January 2002 (has links)
Orientador: Yasmin Rodarte Carvalho / Banca: Carlos Alberto Alves de Cairo / Banca: Antonio Olavo Cardoso Jorge / Resumo: O presente trabalho teve como objetivo analisar a reação do tecido ósseo a implantes confeccionados com a liga de titânio contendo alumínio e nióbio (Ti-6AI-7Nb) em relação ao titânio comercialmente puro (titânio de grau 2). Foram obtidos 48 pinos por metalurgia do pó, os quais foram usinados em implantes de 2,0mm de diâmetro, 7,5mm de comprimento e com 1 ,67mm de rosca, o suficiente para fixação iniciai. O experimento foi realizado em 24 coelhos da raça Nova Zelândia com 3,5 Kg e com aproximadamente três meses e meio de vida. Quatro implantes foram colocados por animal, sendo na tíbia esquerda implantados dois implantes da liga Ti-6AI-7Nb, equidistantes 4cm, e na direita o titânio grau 2. Após os períodos de 21, 42 e 84 dias, os animais foram sacrificados e a interface entre o implante e o tecido ósseo foi analisado em nível histológico, em cortes descalcificados e não descalcificados. As imagens dos cortes não descalcificados foram digitalizadas e submetidas ao programa de análise de imagem, por meio do qual foi calculada a área do osso neoformado entre os passos da rosca. Os resultados mostraram que não houve diferenças da resposta do tecido ósseo ao tipo de material implantado. Em relação ao período de análise, observou-se aos 21 dias maior quantidade de espaços medulares e menor quantidade de osso neoformado que nos outros períodos. Não houve diferença significativa entre os grupos de 42 e 84 dias, que apresentavam tecido ósseo com aspecto mais maduro. Concluiu-se, com o trabalho, que os períodos de 21 e 42 dias são suficientes para analisar a ósseo integração de implantes que não sofreram cargas funcionais, e que a liga de titânio Ti-6AI-7Nb apresentou comportamento semelhante ao titânio de grau 2, podendo ser empregada como alternativa de uso na biomedicina / Abstract: The aim of this work was to analyzed bane tissue reaction concemig to implants materials made of by titanium alloy containing aluminum and niobium (Ti-6Af-7Nb) and compared with pure commercial titanium (grade 2)- The essay was performed in 24 rabbits - New Zealand strain - about 3, 5 Kg e a eh and three and half months of age, in which were placed bodies test manufactured by powder metallurgical technology, and latter on trimmed to aflow final dimensions around 2, O mm in diameter: 7,5 mm in length and 1,67mm in screw saw, size enough to initial bane fixation. Four implants were p/aced on each animal: two Ti-6Af-7Nb in to left tibia bone, distant 4cm from one each other, and last two grade 2 titanium ín to right tibia bone. The animals were sacrificed at different periods of time (21, 42 and 84 days), and the interfaces between implants and bone tissue were histologically analyzed in decalcified and non decalcified samples. image from non decalcified samples were obtained, and then analyzed in a specific image software (lmage G - NIH, USA). Area of new bane tissue formation between grooves were calculated. Data were statistically analyzed by ANOVA and Tukey test. Our results showed there were no statstical differences in bane tissue responses related to this two implant materials. Conceming to the analyzed period we should realized that in 21-dayssamples a quite large amount of medullar spaces and woven bane were presented when compared with the others two periods. The following 42-days-samples and 84-dayssamples díd not show any differences among them. We may conclude that 21 and 42 days were sufficient enough time to analyze osseo integration over implants that did not submitted to functional stress. Finally, we may say that Ti-6Af-7Nb alloy showed similar behavior compared to grade 2 titanium, and tl1erefore, it might be used in medicine for biological applications / Mestre

Page generated in 0.1052 seconds