• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 907
  • 81
  • 78
  • 78
  • 78
  • 68
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 922
  • 922
  • 454
  • 392
  • 234
  • 208
  • 160
  • 149
  • 100
  • 97
  • 81
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Fratura precoce da porcelana em restaurações com infra-estrutura de zircônia: influência de gradientes térmicos no desenvolvimento e magnitude de tensões residuais e transitórias

Benetti, Paula [UNESP] 01 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-01Bitstream added on 2014-06-13T20:45:49Z : No. of bitstreams: 1 benetti_p_dr_sjc.pdf: 1295026 bytes, checksum: 84c067e5318d9cb1124bfd1cbcf324f7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Esse estudo avaliou o desenvolvimento de tensões dentro da porcelana de restaurações metalo-cerâmicas (MC) e de zircônia-porcelana (ZC) como resultado de diferentes taxas de resfriamento a partir de temperaturas acima da transição vítrea (Tg). Restaurações unitárias (coroas) foram fabricadas com 1 ou 2 mm de espessura de porcelana. Termopares foram posicionados nas superfícies de cimentação (T1) e oclusal (T4) e inseridos na interface (T2) e dentro da porcelana (T3). Para o resfriamento rápido, o forno foi aberto imediatamente após o tempo de sinterização e desligado. O resfriamento lento foi obtido pela abertura do forno quando a 50°C abaixo da Tg. Modelos axi-simétricos foram construídos para simulação de tensões térmicas tempo-dependentes usando análise de elementos finitos (AEF). Equações de temperatura em função do tempo obtidas por termopares foram inseridas no modelo como condições das margens. A mudança do coeficiente de expansão térmica, densidade, módulo de cisalhamento, capacidade térmica e da Tg de acordo com a taxa de resfriamento foi considerada para simulação do comportamento da porcelana em temperaturas acima da Tg (visco-elástico). O comportamento dos materiais de infra-estrutura e da porcelana abaixo da Tg foi considerado elástico. A taxa de resfriamento na faixa de temperatura próxima a Tg foi 20°C/min e 900°C/min para resfriamento lento e rápido. Durante o resfriamento lento, os diferentes termopares mostraram temperaturas similares em ambas as coroas. Gradientes de temperatura foram observados no resfriamento rápido da coroa ZC (T1-T4 = 100°C) e, em menor magnitude, para a MC (T1-T4 = 30°C). Os resultados de AEF mostraram diferenças de tensão... / This study evaluated the development of transient and residual stresses within the porcelain of veneered restorations (zirconia- and metal-based) as a result of different cooling rates from temperatures above the glass transition temperature (Tg). All-ceramic (porcelain on zirconia-based ceramic) and porcelain-fused-to-metal (PFM) molar crowns were fabricated with 1 mm or 2 mm porcelain thickness. Thermocouples were attached to intaglio (T1) and occlusal (T4) surfaces and embedded within the ceramics interface (T2) and inside the porcelain (T3) to acquire temperature readings by time. For fast cooling, the furnace was opened immediately after the holding time and switched off afterward. Slow cooling was determined by opening the furnace when it reached 50 °C bellow the Tg. Axially-symmetric crown-like models were constructed to perform a simulation of time-dependent thermal stresses using finite element analyses (FEA). Time-dependent temperature equations from thermocouples were set as boundary conditions for surfaces of the model. Coefficient of thermal expansion, density, shear modulus, heat capacity and Tg dependency on cooling rate were considered for the porcelain simulation (visco-elastic above Tg). Porcelain below the Tg and the framework materials were considered to behave elastically. The cooling rates at Tg range were 20 °C/min and 900 °C/min for slow and fast cooling. During slow cooling, different thermocouples showed similar temperatures for both zirconia and metal crowns. Remarkable temperature gradients were observed for the fast cooled all-ceramic crown (T1-T4 = 100 °C) and, of lower magnitude, for PFM (T1-T4 = 30 °C). FEA results showed differences... (Complete abstract click electronic access below)
372

Influência de diferentes protocolos de jateamento na resistência à flexão e na estabilidade estrutural de uma cerâmica policristalina de zircônia tetragonal parcialmente estabilizada com ítria

Souza, Rodrigo Othávio de Assunção e [UNESP] 13 August 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-08-13Bitstream added on 2014-06-13T19:05:09Z : No. of bitstreams: 1 souza_roa_dr_sjc.pdf: 6581184 bytes, checksum: 4f86438bdc1d92ecc5aaf0fbfa8a4c53 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou o efeito de diferentes protocolos de jateamento na resistência à flexão biaxial e na estabilidade estrutural de uma cerâmica de Y-TZP. Para tanto, duzentos e dezesseis discos sinterizados de Y-TZP (Lava, 3M ESPE) (ISO 6872, diâmetro: 15 mm, espessura: 2 mm) foram confeccionados pelo fabricante. Para o ensaio de resistência à flexão, 180 discos (n=10) foram divididos entre 18 grupos de acordo com os fatores “tipo de partícula (Al2O3- 50 e 110μm; SiO2- 30 e 110 μm)”, “pressão (2,5 e 3,5 bar)” e “ciclagem mecânica (CM) (com e sem)”. O jateamento foi realizado a uma distância de 10 mm e com duração de 20 s: Gr1- Controle – (sem tratamento de superfície); Gr2- Al2O3 50 μm/2,5 bar; Gr3- Al2O3 50 μm/3,5 bar; Gr4- Al2O3 110 μm/2,5 bar; Gr5- Al2O3 110 μm/3,5 bar; Gr6- SiO2 30 μm/2,5 bar; Gr7- SiO2 30 μm/3,5 bar; Gr8- SiO2 110 μm/2,5 bar; Gr9- SiO2 110 μm /3,5 bar. Os grupos Gr10 a Gr18 são respectivamente os grupos anteriores submetidos à CM (100.000 ciclos, 50 N, 4 Hz, água 370C. Em seguida todas as amostras foram submetidas ao ensaio de resistência à flexão biaxial (ISO 6872) em máquina de ensaio universal (EMIC, 1 mm/min). Após ensaio de flexão, os dados obtidos (MPa) foram submetidos ao teste de Dunnett (5%) e à Análise de Variância (3 fatores). Para determinar a quantidade e profundidade de possíveis transformações de fase da zircônia (t→m) induzida pelo jateamento e/ou pela ciclagem mecânica, foi realizada a análise de difração de Raios-X em vinte amostras (n=2) dos grupos Gr1 ao Gr9 e Gr18, antes e após tratamento térmico (ciclo de queima da VM9/Vita). Os resultados demonstraram que todos os protocolos de jateamento promoveram um aumento significativo da resistência à flexão da cerâmica de Y-TZP em relação... / This study evaluated the effect of different air-particle-abrasion protocols on the biaxial flexural strength and on the structural stability of Y-TZP ceramic. Disc shaped (ISO 6872, Ø: 15 mm, thick: 2 mm) sintered zirconia specimens (N=216) were obtained from the manufacturer (Lava, 3M ESPE). To the flexure test 180 discs (n=10) were divided among the groups according to the factors “particle (Al2O3 50 and 110μm; SiO2 30 and 110 μm)”, “pressure (2.5 and 3.5 bar)” and “mechanical cycling (MC)(with and without)”. The air-particle-abrasion protocols were performed with 10 mm of distance and duration of 20 s: Gr1- Control – (without air-particle-abrasion); Gr2- Al2O3 50 μm/2,5 bar; Gr3- Al2O3 50 μm/3,5 bar; Gr4- Al2O3 110 μm/2,5 bar; Gr5- Al2O3 110 μm/3,5 bar; Gr6- SiO2 30 μm/2,5 bar; Gr7- SiO2 30 μm/3,5 bar; Gr8- SiO2 110 μm/2,5 bar; Gr9- SiO2 110 μm /3,5 bar. The groups Gr10 to Gr18 are those groups before submitted to MC, respectively (100.000 cycles; 50 N, 4 Hz, water 370C). After, all specimens were tested for biaxial flexural strength (ISO 6872) in a universal testing machine (EMIC). After, all specimens were tested for biaxial flexural strength (ISO 6872) in a universal testing machine (EMIC). The data were submitted to statistical tests ANOVA and Dunnett (5%). To determine the percentage and deep of possible zirconia transformations (te mo) after the air-particle-abrasion protocols and/or MC, the X-Ray diffraction was performed on 20 samples (n=2) from the groups Gr1 to Gr9 and Gr18, before and after thermal treatment (VM9/Vita firing cycle). The results showed that all air-particle-abrasion protocols increased significantly the flexure strength of the Y-TZP ceramic compared to the negative Control... (Complete abstract click electronic access below)
373

Profundidade de polimerização de cimentos resinosos utilizados na cimentação de pinos translúcidos e sua influência sobre a resistência adesiva antes e após ciclagem mecânica

Galhano, Graziela Ávila Prado [UNESP] 16 May 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-05-16Bitstream added on 2014-06-13T18:46:00Z : No. of bitstreams: 1 galhano_gap_dr_sjc.pdf: 385997 bytes, checksum: e9e65faf9da79b458c552d9829193cca (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve com objetivo analisar a capacidade de um pino translúcido transmitir luz para o interior do canal radicular, bem como analisar o efeito desta polimerização na resistência mecânica e adesiva do conjunto pino, cimento, dente. Além disso, foi avaliada a resistência adesiva de diferentes tipos de cimentos resinosos. Foram utilizados 70 dentes humanos unirradiculares. O canal foi preparado com as fresas n°3 dos sistemas de pinos Light-Post (Bisco Inc, EUA). As raízes foram pintadas com esmalte preto para evitar a passagem de luz pela lateral do dente. Todos os dentes foram tratados com o sistema adesivo All Bond 2 (Bisco) e cimentados com três tipos de cimento formando os seguintes grupos: G1) Cimento Dual Duolink (Bisco) não fotopolimerizado, G2) Cimento Dual duolink fotopolimerizado, G3) Cimento Químico (C&B - Bisco) e G4) cimento fotopolimerizável (Illusion, Bisco). Cada grupo foi subdividido segundo a execução ou não de ciclagem mecânica. Em seguida, os dentes foram cortados perpendicular ao longo eixo do dente obtendo espécimes de 2mm de espessura. Cada secção era correspondente a uma região do dente (cervical, média, apical), possibilitando observar a polimerização do cimento nas diferentes profundidades da raiz realizando a analise Raman em três dentes de cada grupo. Em seguida, foi realizado o teste de push-out.Como resultado foi observado menor grau de conversão em direção apical para os cimentos foto-ativados, enquanto o cimento dual sem foto-ativaçao apresentou maiores valores. Para a resistência adesiva foi observada semelhança estatística inicial entre o cimento Duolink foto-ativado ou não, sendo que q ciclagem mecânica diminui consideravelmente a RA do Duolink quimicamente polimerizado. O cimento fotopolimerizável apresentou valores muito baixos de resistência adesiva e o cimento químico C&B apresentou os maiores valores antes e apos ciclagem mecânica. / This study aimed to evaluate the light transmittance of a translucent post in the root canal, as well as the effects of light polymerization onto fatigue resistance and bond strengths at the post/cement/tooth joint. Moreover, the bond strengths obtained with different types of resin cement were determined. 70 human teeth were used. The root canals were prepared with Light Post drills (Bisco Inc, EUA) (size 3). Afterwards, the outer surface of each tooth was covered with black nail varnish to avoid passage of light through the root lateral walls. All teeth were treated with All Bond 2 (Bisco) bonding agent. They were divided into groups according to the resin cement: G1) non light-cured Duo-link dual-cure cement (Bisco), G2) light-cured Duo-link dual-cure cement, G3) C&B chemical-cure cement (Bisco) and G4) Illusion light-cure resin cement (Bisco). Each group was divided into subgroups, to designate the specimens subjected to mechanical cycling or not. Following that, the teeth were sectioned perpendicular to their long axis into 2mm sections. Each section corresponded to one of three study regions (cervical, middle and apical regions of the root canal preparation), allowing the determination of the degree of conversion at different levels of the root by using Raman spectroscopy in three teeth per group. Afterwards, the segments were subjected to Push-out bond strength test. The light-activated cements had the lowest degree of conversion towards the apical region whereas the dual-activated one presented the highest values. As for bond strength, the light- and non light-activated Duo-link groups were statistically similar in the beginning, but the mechanical cycling decreased the bond strength of the non light-activated group. The light-activated cement had the lowest bond strengths and the chemical cement (C&B) presented the highest bond strength values before and after mechanical cycling.
374

Síntese e caracterização de novos materiais compósitos orgânicos/inorgânicos, fotopolimerizáveis, para uso em restaurações odontológicas

Gatti, Alexandre [UNESP] 10 September 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-09-10Bitstream added on 2014-06-13T18:46:24Z : No. of bitstreams: 1 gatti_a_dr_araiq.pdf: 2376278 bytes, checksum: dc9083c530518cab8f1c2e3fee92577b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O presente trabalho de tese envolveu o estudo de formulações e o desenvolvimento de compósitos orgânicos/inorgânicos, fotopolimerizáveis, para uso em odontologia, tomando-se por base formulações comerciais. Estudou-se o efeito do tipo dos monômeros nas propriedades mecânicas e na cinética de polimerização de compósitos experimentais, utilizando-se como fotoiniciador o BAPO (Irgacure 819®), que foi escolhido com base em resultados de fotocalorimetria. O compósito com a maior resistência e módulo flexural foi obtido utilizando-se como monômeros uma mistura de bisfenol A diglicidil éter dimetacrilato (Bis-GMA), trietilenoglicol dimetacrilato (TEGDMA) e uretano dimetacrilato (UDMA), na proporção mássica de 40:40:20, contendo 50% (m/m) de partículas de sílica funcionalizadas. Foram sintetizadas esferas de sílica opalescentes, monodispersas, com tamanho médio de 160 nm, através da metodologia de Stöber. Estas foram funcionalizadas superficialmente com grupos metacrílicos para serem utilizadas como reforço. Posteriormente, foi preparada uma segunda classe de compósitos contendo oxoclusters de zircônio modificados por grupos metacrílicos, sintetizados pela mistura de alcoóxidos de zircônio, em meio alcoólico, e ácido metacrílico, em diferentes proporções molares. A adição de 5% (m/m) do oxocluster formado pela mistura de 1:5 (mol/mol) de n-butóxido de zircônio (em solução de n-butanol) e ácido metacrílico, respectivamente, fez com que a resistência à flexão do polímero puro aumentasse de 62,70 MPa para 129,9 MPa (aumento de 107%) e seu módulo passasse de 1770 MPa para 3260 MPa (aumento de 84,2%). Resultados de Espalhamento de raios X em Baixo Ângulo (SAXS) levaram à identificação dos oxoclusters no meio polimérico com padrões de dispersão bem definidos. Como resultado tecnológico do trabalho de tese foi proposta uma empresa através... / In the present thesis is showed the study and development of experimental dental photopolimerizable organic/inorganic composites, based upon commercial formulations. It was studied the influence of the monomers types on the mechanical and kinetical behavior of some experimental composite formulations, using BAPO (Irgacure 819®) as photoinitiator, that was prior chosen through photocalorimetry measurements. The most resistant composite was obtained using as monomers a mixing of bisphenol A diglycidyl ether dimethacrylate (Bis-GMA), triethylene glycol dimethacrylate (TEGDMA) and urethane dimethacrylate (UDMA) in the mass proportion of 40:40:40, containing 50% (w/w) of functionalized silica particles. It was synthesized monodisperse silica spheres, with an average size of 160 nm, through Stöber’s methodology. It receives a methacrylic surface treatment to be used as reinforcement. Afterwards, a second group of composites were prepared using as reinforcement methacrylic modified zirconium oxoclusters prepared through the mixing of zirconium alkoxides, in alcoholic medium, and methacrylic acid, in different molar ratios. The addition of 5% (w/w) of the oxocluster synthesized through the mixture of 1:5 (mol/mol) of the zirconium n-butoxide (in n-butanol solution) and methacrylic acid, respectively, in the polymer, makes it flexural strength raises from 62.70 MPa to 129.9 MPa (increase of 107%) and the Young’s modulus changes from 1170 MPa to 3260 MPa (increase of 84.2%). Small Angle X ray Scattering (SAXS) measurements allow the identification of the oxoclusters in the polymeric medium with a well defined dispersion pattern. As result of this thesis a company was proposed through the Program of Innovative Research in the Small Company (PIPE) fomented by the Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) that is a government foundation which supports the research in the São Paulo State – Brazil.
375

Efeito de protocolos de cimentação na carga de fratura para uma cerâmica de dissilicato de lítio

Carvalho, Rodrigo Furtado de [UNESP] 09 May 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-05-09Bitstream added on 2015-05-14T16:59:04Z : No. of bitstreams: 1 000822600.pdf: 941944 bytes, checksum: 97d90be7cb4e5c631df49dc5b45df407 (MD5) / Foi proposto avaliar a carga de fratura de restauração cerâmica à base de dissilicato de lítio (IPS e.max CAD) submetida a diferentes protocolos de cimentação. Foram confeccionadas 70 bases de um material resinoso análogo à dentina (NEMA grade G10) simulando de maneira padronizada dentes preparados para coroa total (término em chanfro com paredes de 6 graus de convergência) e a anatomia da raiz. A porção radicular foi coberta com poliéter e incluída em poliuretano. Setenta coroas cerâmicas foram fabricadas pelo sistema CAD/CAM. Depois de avaliar a espessura do filme de cimento (técnica do cimento análogo) as coroas foram limpas em ultra-som com água destilada (5 min). Posteriormente, as coroas foram submetidas a diferentes protocolos de cimentação: FZ-cimento de fosfato de zinco; IVMR-cimento de ionômero de vidro modificado por resina; RDCS-ácido fluorídrico 5 % (20 s) + silano (1 min) + cimento resinoso dual; RDCST-ácido fluorídrico 5% (20 s) + silano (1 min) + tratamento térmico forno 100 °C (2 min) + cimento resinoso dual; RDS-silano (1 min) + cimento resinoso dual; RDST-silano (1 min) + tratamento térmico forno 100 °C (2 min) + cimento resinoso dual; RAACS-ácido fluorídrico 5% (20 s) + silano (1 min) + cimento resinoso auto-adesivo. Todas as amostras foram submetidas à ciclagem termomecânica (2.000.000 ciclos - 100 N, 4 Hz, 5 ºC - 55 ºC, tempo de permanência 60 s), com um pistão de aço inoxidável (Ø=4mm) no centro da superfície oclusal. O teste da carga de fratura foi realizado em uma máquina de ensaios universal (v = 1 mm/min à 37 °C em água destilada). Os dados de carga de fratura (N) foram submetidos aos testes ANOVA (um fator) e Tukey, com α = 0,05. Realizou-se a análise de elementos finitos para verificação da distribuição das tensões na coroa. Por meio do microscópio eletrônico de varredura foram realizadas, em duas amostra de cada... / It was proposed to evaluate the load of fracture of a ceramic restoration-based lithium disilicate (IPS e.max CAD) submitted to different protocols cementation. 70 bases were made of a resin material similar to dentin (NEMA grade G10) to provide standardized preparations, machined to simulate a tooth prepared for full crown (ending Bevel with walls of 6 degrees of convergence) and the anatomy of the root. The root portion was covered with polyurethane poliétere included. Seventy ceramic crowns were fabricated by CAD / CAM system. After evaluating the film thickness of cement (cement analogue technique) crowns were cleaned with distilled water in ultra-som (5 min). Subsequently, the crowns were subjected to different protocols cementation: FZ-zinc phosphate cement; IVMR-ionomer resin modified glass; RDCS-hydrofluoric acid 5% (20 s) + silane (1 min) + dual resin cement , RDCST-hydrofluoric acid 5% (20 s) + silane (1 min) + heat treatment furnace 100 °C (2 min) + dual resin cement; RDS-silane (1min) + dual resin cement; RDST silane (1 min) + heat treatment furnace 100 °C (2 min) + dual resin cement; RAACS-hydrofluoric acid 5% (20 s) + silane (1 min) + self-adhesive resin cement. All samples were subjected to thermomechanical cycling (2,000,000 cycles - 100N, 4 Hz, 5 ºC - 55 ºC, dwell time 60 s), with a stainless steel piston (Ø = 4 mm) in the center of the occlusal surface. The fracture toughness test was performed in a universal testing machine (v = 1 mm/min at 37 ° C in distilled water). Data fracture resistance (N) were subjected to ANOVA (one factor) and Tukey's test with α = 0.05. We conducted a finite element analysis to check the distribution of the stresses on the crown. Through scanning electron microscopy were performed on two samples from each group, representative photomicrographs of surface treatment . For fractographic analysis, we used the stereo type of fracture...
376

Caracterização de uma cerâmica 3Y-TZP e avaliação do efeito de tratamentos de superfície na adesão da cerâmica ao glaze ou cimento resinoso

Feitosa, Sabrina Alves [UNESP] 12 February 2015 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:33:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-12. Added 1 bitstream(s) on 2015-06-18T12:48:09Z : No. of bitstreams: 1 000827138.pdf: 1409159 bytes, checksum: 0b9d93f3a376f761231d70d0d839d707 (MD5) / O objetivo do presente estudo foi avaliar os parâmetros de adesão entre glaze e full-contour zirconia (FCZ) e FCZ glazeada e cimento resinoso. Zircônia e glaze tiveram as suas propriedades caracterizadas. Amostras de FCZ foram divididas em 5 grupos: (GL) aplicação de glaze; (AL+GL) jateamento com óxido de alumínio + glaze; (CJ+GL) partículas de óxido de alumínio modificada por sílica (Cojet®) + glaze; (SP+GL) tratamento químico com solução piranha + glaze; (CJ) Cojet. Microscopia eletrônica de varredura (MEV) e de força atômica (MFA) foram realizadas para avaliar a topografia das amostras. Scratch test foi realizado para avaliar o tipo de união entre zircônia e glaze após os diferentes tratamentos [(GL), (AL), (CJ) e (SP). Durante a cimentação, os grupos glazeados [(GL), (AL+GL), (CJ+GL) e (SP+GL)] foram tratados com ácido fluorídrico (HF) e silano; e o grupo não glazeado (CJ) apenas com silano. O cimento resinoso foi unido à zircônia utilizando um dispositivo específico para o teste de cisalhamento (SBS). Para a realização do teste SBS, metade dos espécimes de cada tratamento foi ensaiada 24 h após a cimentação e a outra metade foi envelhecida (armazenagem e termociclagem). Para a avaliação da retenção, foram confeccionados coroas FCZ e preparos para coroa total em substrato de resina epóxica (G10) (simulando um dente). Os grupos que receberam tratamento na superfície interna da coroa [(GL), (CJ+GL), (SP+GL) e (CJ)] foram cimentados com cimento resinoso sem MDP (Multilink Automix, 3M). O grupo que não recebeu tratamento na superfície interna (PF) foi cimentado utilizando um cimento resinoso contendo MDP (Panavia F, Kuraray). Os dados de adesão foram analisados estatisticamente (ANOVA e Tukey test). A full-contour zirconia apresentou alta densidade, microestrutura homogênea e propriedades mecânicas comparáveis à zircônia tradicional. O glaze ... / The aim of the present study was to evaluate the adhesive parameters between glaze and full-contour zirconia (FCZ) and overglazed FCZ and resin cement. Zirconia and glaze were tested to determined theirs properties. FCZ samples were divided into 5 groups: (GL) glaze application; (AL+GL) sandblasting with aluminum oxide + glaze; (CJ+GL) tribochemical silica coating (Cojet®) + glaze; (SP+GL) chemical surface treatment with piranha solution+glaze; (CJ) Cojet. Electron scanning microscopy (SEM) and atomic force microscopy (MFA) were performed to evaluate the FCZ topography. Scratch test was executed to evaluate the bonding between FCZ and glaze after the different surface pretreatment. For the bonding procedures the glazed groups [(GL), (AL+GL), (CJ+GL) and (SP+GL)] were etched with hydrofluoric acid (HF) and treated with a silane coupling agent and the group without glaze (CJ) was treated only with a silane. The resin cement was bonded to the zirconia surface using a dedicated device for the shear test (SBS). For the SBS test, half of the samples were tested after 24 h and the other half after storage and thermocycling. To evaluate the tensile retention of FCZ crowns cemented on epoxy resin (G10) specimens simulating fullcontour crowns were made. Pretreated groups [(GL), (CJ+GL), (SP+GL) and (CJ)] were bonded with a resin cement without MDP (Multilink Automix, 3M). The group without surface pretreatment (PF) was bonded with a MDP-based resin cement (Panavia F, Kuraray). The adhesive data were statistically analysed (ANOVA e Tukey test). FCZ showed high density, homogeneous microstructure and mechanical properties similar to the traditional zirconia. FCZ glaze was characterized as a leucite with irregular shape and size morphology. The scratch test pattern was similar for all the evaluated groups and classified as a cohesive failure of the glaze. The shear data suggested that the chemicall ...
377

Desenvolvimento e validação de um novo protocolo para ciclagem térmica de materiais dentários

Marinho, Caroline Cotes [UNESP] 06 February 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-06. Added 1 bitstream(s) on 2015-09-17T15:48:10Z : No. of bitstreams: 1 000843412.pdf: 3288737 bytes, checksum: cc08736358fae84d0cc13c384a8935a4 (MD5) / Este trabalho teve como objetivos: avaliar a variação térmica que ocorre em ambiente bucal para predizer a quantidade e duração das variações de temperatura por dia, a temperatura máxima e mínima encontrada na cavidade oral e sugerir um novo protocolo de ciclagem térmica baseado nestas informações; e comparar os resultados de resistência de união após várias formas de envelhecimento. Para tal, foi instalado um sensor térmico wireless no palato de um aparelho parcial removível de seis voluntários, e estes foram monitorados durante três dias para desenvolvimento de um novo protocolo de ciclagem térmica. Após esta etapa, 40 blocos de cerâmica feldspática foram cimentados entre si (N=20), divididos em cinco grupos (n=4) e cortados em fatias. As fatias foram submetidas aos seguintes tipos de envelhecimento: C, teste imediato (sem envelhecimento); A, armazenagem em água por 30 dias; E, protocolo de ciclagem térmica experimental desenvolvido neste estudo; CIB, ciclagem intra-bucal; e ISO, protocolo de ciclagem térmica estabelecido pela norma ISO 11405 (2003). As fatias foram cortadas em palitos, os quais foram submetidos ao teste de microtração. A análise de falha foi realizada com o auxílio de um estereomicroscópio. A temperatura máxima encontrada foi de 47,59 ̊C, a mínima foi de 13,11 ̊C. A média de temperatura diária manteve-se entre 34 ̊C e 36 ̊C. A média de variação de temperatura por dia foi de 5,3 vezes, com duração média de 183 s. Os grupos A, CIB, E apresentaram valores de resistência de união estatisticamente menor que o grupo C (p-valor=0,0002), sendo semelhantes entre si. O grupo ISO foi semelhante aos grupos C e CIB. O modo de falha mais encontrado para todos os grupos foi do tipo mista. Conclui-se que ocorrem em média 6 variações térmicas por dia, com duração de 180 segundos. O protocolo de ciclagem térmica sugerido pela ISO não foi capaz de reduzir a resistência de uniâo. A ciclagem.. / This study aimed to evaluate the thermal variation that occurs in the oral environment; predicted the number of thermal cycles and temperature variation which occurs during certain time periods and compared the results of the bond strength of ceramic and luting agent after different aging protocols. For this purpose, six volunteers used a removable device with wireless thermal sensor and they were monitored for three days, to develop a new thermal cycling protocol. After this step, 40 feldspathic ceramic blocks were cemented together with a resin luting agent (N = 20), divided into five groups (n = 4) and cut into slices. Aging of the slices were: C, immediate test (without aging); A, storage in water for 30 days; E, thermal cycling experimental protocol developed in this study; CIB, storage of the slices in mouth for 30 days; and ISO, thermal cycling protocol established by ISO 11405 (2003). The slices were cut into sticks for microtensile test. The failure analysis were performed in a stereomicroscope. Maximum temperature observed was 47.59 ̊C, the lowest temperature was 13.11 ̊C. The average daily temperature is between 34 ̊C and 36 ̊C. The average temperature change per day was 5.3 times, with an average duration of 183 s. A, CIB, and E groups showed strength values statistically lower than C group (p-value = 0.0002), and they were similar among them. The ISO group was similar to the groups C and IB. The failure type most commonly found for all groups was mixed mode. It concluded that occurs daily 6 temperature variations, with duration of 180 seconds. The ISO thermocycling protocol did not reduce the bond strength. The experimental cycling used in E, 180 thermal cycles with a temperature range of 50 ̊C and 10 ̊C for 180 seconds each and 36 ̊C intermediate baths was able to accelerate the degradation process of bond between ceramic and cement that occurred during storage in water for 30 days
378

Efeito de nanofilmes depositados a plasma na resistência de união de um cimento resinoso a uma cerâmica à base de zircônia

Figueiredo, Viviane Maria Gonçalves de [UNESP] 07 October 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-07. Added 1 bitstream(s) on 2015-09-17T15:47:44Z : No. of bitstreams: 1 000843821.pdf: 3702436 bytes, checksum: d6873085a79717fb329e4d79616a41ad (MD5) / Esta pesquisa objetivou avaliar o efeito de diferentes nanofilmes depositados a plasma na resistência de união entre cimento resinoso e cerâmica à base de zircônia. 120 blocos/espécimes (15,2 x 12,5 x 1,7 mm) e 18 discos (11,0 x 1,4 mm) de zircônia (Y-TZP) (VITA In-Ceram Zirconia, Vita Zahnfabrik, Alemanha) receberam diferentes tratamentos de superfície (n = 20 para os blocos) (n = 3 para discos): zircônia sem tratamento (Zrpolida), jateamento de alumina revestida por sílica (30 μm) (Zrjat#), nanofilme à base de sílica (ZrSiO2), jateamento de alumina (45 μm) + nanofilme à base de sílica (Zrjat+SiO2), e nanofilme à base de fluoreto (ZrF) e jateamento de alumina (45 μm) + nanofilme à base de fluoreto (Zrjat+F). Os nanofilmes foram depositados por meio da técnica a plasma PECVD. As superfícies cerâmicas foram caracterizadas pela morfologia (MEV e MFA), química (XPS) e molhabilidade (ângulo de contacto), realizada nos discos. O agente de união silano foi aplicado em cada superfície e um cilindro de cimento resinoso foi construído sobre os espécimes tratados. Metade dos espécimes de cada grupo (n = 10) foram submetidos a 6.000 ciclos térmicos. A resistência de união foi avaliada pelo teste de cisalhamento e análise fractográfica pelo estereomicroscópico, MEV e EDS. Para análise estatística utilizou-se ANOVA 1-Fator e o teste de Tukey, para presença e ausência de envelhecimento (p = 0,05). A zircônia apresentou-se mais hidrofílica após a deposição dos nanofilmes. Ligações químicas entre Si-O foram encontradas em ZrSiO2; ZrF promove um processo de fluoração na superfície da cerâmica Y-TZP, convertendo-a em oxifluoreto de zircônio. Os valores de resistência de união iniciais obtidos pelos tratamentos de superfície a plasma não superaram os valores de união da silicatização. Após o envelhecimento, todas as amostras do grupo ZrSiO2(TC) sofreram falhas pré-teste. OS valores de resistência de.... / This study aimed to evaluated the effects of differents plasma nanofilms on the bond strength between resin cement and zirconia ceramic. 120 blocks / specimens (15.2 x 12.5 x 1.7 mm) and 18 discs (11.0 x 1.4 mm) of zirconia (Y-TZP) (VITA In-Ceram Zirconia, Vita Zahnfabrik, Germany) received differents treatments surface (n = 20 for the blocks) (n = 3 for discs): untreated zirconia (Zrpolida), silica-coated (30 μm) (Zrjat#), silica nanofilm (ZrSiO2), sandblasted by air-borne particle abrasion with aluminum oxide particles (45 μm) + silica nanofilm (Zrjat+SiO2) and fluoride nanofilm (ZrF) and sandblasted by air-borne particle abrasion with aluminum oxide particles (45 μm) + fluoride nanofilm (Zrjat+F). The nanofilms were deposited by PECVD technique of the plasma. The ceramic surfaces were characterized by morphology (SEM and AFM), chemical (XPS) and wettability (Contact angle), that was performed on discs. The silane agent was applied to each surface treatment and a cylinder of resin cement was built on the specimens. Half of the samples of each group (n = 10) were subjected to 6.000 thermalcycles. The bond strength was evaluated by shear test and fractographic analysis by stereoscopic, SEM and EDS. Statistical analysis was performed using one-way ANOVA and Tukey's test for the presence and absence non-aged (p = 0.05). Zirconia presented more hydrophilic after nanofilms deposition. Chemical bonds between Si-O were found in ZrSiO2; ZrF promotes a process of fluorination on the Y-TZP surface, promoting the conversion of zirconia in zirconium oxyfluoride. The initial values of bond strength obtained by plasma treatment did not exceed the bond values of the silica-coated. After aging, all samples of the group ZrSiO2 (TC) falied. The values of bond strength of ZrF (TC) (3.8 MPa) were lower than Zrjat# (TC) (15.4 MPa) and Zrpolida (TC) (6.3 MPa). The silica nanofilm showing detachment after shearing. Adhesive failures were predominant among the...
379

Efetividade e sensibilidade com uso de géis clareadores experimental e comercial à base de peróxido de carbamida

Santana, Rosemary Soares de [UNESP] 24 November 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-11-24. Added 1 bitstream(s) on 2015-09-17T15:47:37Z : No. of bitstreams: 1 000843725.pdf: 2672521 bytes, checksum: ef18b307626f61cbba5deea1437f2396 (MD5) / Este estudo clínico avaliou a sensibilidade dentária (SD) e a efetividade do clareamento caseiro, bem como a reincidência de cor após uso de géis, à base de peróxido de carbamida (CP) comerciais contendo nitrato de potássio e fluoreto (PF) e experimentais (EX) contendo também tripolifosfato de sódio (STP). Cem pacientes foram submetidos ao tratamento de clareamento dental, sendo divididos aleatoriamente em 5 grupos (n = 20 / grupo): 1) Peróxido de carbamida PF Mint gel experimental 10% (EX10); 2) Peróxido de carbamida PF Mint gel experimental 20% (EX20); 3) Peróxido de carbamida comercial 10% (Opalescence PF 10% Mint) (OP10); 4) Peróxido de carbamida comercial 20% (Opalescence PF 20% Mint) (OP20); 5) Gel placebo de peróxido de carbamida (PL). Realizou-se clareamento em uma única arcada de cada paciente, por 2 horas/dia, durante 14 dias. Para análise da cor utilizou-se análise por espectrofotômetro, análise fotográfica e pela escala Vita Bleachedguide 3D Master nos períodos: inicial, 7 e 14 dias após o início do tratamento e 30 dias após o término para verificar a estabilidade da cor. A SD foi avaliada diariamente qualificando a intensidade da dor em: ausência, discreta, moderada, considerável e severa. Os resultados foram analisados pelos testes ANOVA (medidas repetidas) para mensuração por espectrofotômetro, teste Kruskal-Wallis para sensibilidade e Dunn para escala visual, significância 5%. A análise de cor visual apresentou p < 0.05, e a sensibilidade 0.0482 < 0.05. O gel de clareamento OP10 promoveu melhores resultados de cor e menor sensibilidade comparado ao EX10. O grupo EX20 apresentou maior ação clareadora com mesmo nível de sensibilidade que o grupo OP20. Concluiu-se que os grupos OP10 e EX20 promoveram os melhores resultados quanto ao clareamento com menor índice de sensibilidade quando comparados com os grupos de mesmas concentrações e que o STP influenciou na efetividade do clareamento / This clinical study assessed tooth sensitivity (SD) and the effectiveness of home bleaching as well as the color relapse after the use of based on commercial carbamide peroxide gels (CP) containing potassium nitrate and fluoride (PF) and experimental gels (EX) also containing sodium tripolyphosphate (STP). A hundred patients, who underwent tooth whitening treatment, were divided randomly into 5 groups (n = 20/groups): 1) 10% carbamide peroxide experimental gel PF Mint (EX10); 2) 20% carbamide peroxide experimental gel PF Mint (EX20); 3) 10% commercial carbamide peroxide gel (Opalescence 10% Mint PF) (OP10); 4) 20% commercial carbamide peroxide (Opalescence 20% Mint PF) (OP20); 5) placebo 0% carbamide peroxide gel PF mint (PL). Bleaching was performed on a single arch of each patient for 2 hours during 14 days. In order to evaluate the color, it was used spectrophotometer, photographic analysis, and Vita 3D Master Bleachedguide in the periods: initial, 7 and 14 days after the start of the treatment and 30 days after the end to verify the color stability. The SD was daily evaluated, according in the following grades: absence, mild, moderate, substantial and severe. The results were analyzed by ANOVA (repeated measures) for measurement by spectrophotometer, Kruskal-Wallis and Dunn tests, 5% of significance to sensitivity to visual scale. Comparisons of shade guide the color analysis showed p < 0.05, and sensitivity to 0.0482 < 0.05. The whitening gel OP10 promoted better color results and minor sensitivity compared to the EX10. And the EX20 group showed greater lightening action with same level of sensitivity as the OP20 group. It was concluded that the groups OP10 and EX20 promoted the best results regarding the whitening with the smallest rate of sensibility when compared to the groups with the same concentrations and there was STP influence on the whithening effectiveness
380

Caracterização microestrutural e crescimento subcrítico de trincas em cerâmicas odontológicas

Ramos, Nathália de Carvalho [UNESP] 04 December 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-04. Added 1 bitstream(s) on 2015-09-17T15:47:29Z : No. of bitstreams: 1 000843256.pdf: 2592220 bytes, checksum: 1ec5f3c0ca72d4c6345c86434648f82e (MD5) / O objetivo do trabalho foi caracterizar a microestrutura de quatro cerâmicas odontológicas CAD/CAM e avaliar a susceptibilidade à corrosão sob tensão. MEV-FEG e análise química com EDS foram realizados para a caracterização microestrutural. Para avaliar o padrão de cristalização das cerâmicas foi usado DRX e FT-IR. Módulo elástico, coeficiente de Poisson, densidade e tenacidade à fratura também foram mensurados. Os espécimes foram submetidos ao ensaio de flexão biaxial sob cinco taxas de tensão constante (0,006; 0,06; 0,6; 6 e 60 MPa/s), a fim de se determinar os parâmetros de crescimento subcrítico da trinca (CST) (n = coeficiente se susceptibilidade ao CST). Vinte e cinco espécimes foram ensaiados na maior taxa de tensão em óleo mineral para determinar a resistência inerte e realizar a análise de Weibull. Duzentos e quarenta discos cerâmicos (12 mm de diâmetro e 1,2 mm de espessura) foram feitos de quatro cerâmicas: cerâmica infiltrada por polímero - CIP (Vita Enamic, Vita Zahnfabrik, Bad Sackingen, Alemanha), cerâmica feldspática - FEL (Vita Mark II, Vita Zahnfabrik), cerâmica de dissilicato de lítio - DSL (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) e cerâmica de silicato de lítio reforçada por zircônia - SLZ (Vita Suprinity, Vita Zahnfabrik). A CIP foi caracterizada como geopolímero reforçado com polímeros, apresentando uma fase orgânica e outra inorgânica, obteve n = 29,1 ± 7,7 e módulo de Weibull (m) de 8,96. A FEL apresentou n = 36,6 ± 6,8 e m = 8,02. O DSL mostrou uma estrutura com grãos afilados de dissilicato envoltos em uma matriz vítrea e obteve o menor valor de n (8,4 ± 0,8) e m = 6,19. O SLZ mostrou grãos semelhantes a bastonetes, n = 11,2 ± 1,4 e m = 9,98. FEL apresentou menor susceptibilidade à corrosão sob tensão, DSL e SLZ apresentaram maior susceptibilidade. A CIP apresentou menor módulo elástico e nenhum cristal em sua composição. SLZ mostrou a presença... / The aim of this study was to characterize the microstructure of four dental CAD-CAM ceramics and evaluate their susceptibility to stress corrosion. SEM and EDS were performed for microstructural characterization. For evaluation of the pattern of crystallization of the ceramics and the molecular composition, XRD and FTIR, respectively, were used. Elastic modulus, Poisson's ratio, density and fracture toughness were also measured. The specimens were subjected to biaxial flexure under 5 stress rates (0.006, 0.06, 0.6, 6 and 60 MPa/s) to determine the subcritical crack growth parameters (n and D). Twenty five specimens were further tested in mineral oil for determination of Weibull parameters. Two hundred forty ceramic discs (12 mm diameter and 1.2 mm thick) were made of four ceramics: feldspathic ceramic - FEL (Vita Mark II, Vita Zahnfabrik), ceramic-infiltrated polymer- PIC (Vita Enamic, Vita Zahnfabrik), lithium disilicate - LD (IPS e.max CAD, Ivoclar Vivadent) and zirconia-reinforced lithium silicate- LS (Vita Suprinity, Vita Zahnfabrik). PIC was characterized as a geopolymer reinforced by polymers. It presented organic and inorganic phases (n = 29.1 ± 7.7) and Weibull modulus (m) of 8.96. The FEL showed n = 36.6 ± 6.8 and m = 8.02. The LD showed a structure with needle-like disilicate grains in a glassy matrix and had the lowest value of n (8.4 ± 0.8) and m= 6.19. The ZLS showed similar rod-like grains, n = 11.2 ± 1.4 and m= 9.98. The FEL showed the lowest susceptibility to SCG corrosion, where as LD and ZLS presented the highest. The PIC presented the lowest elastic modulus and no crystals in its composition. ZLS presented tetragonal zirconia in its composition and showed the highest Weibull modulus among the materials studied

Page generated in 0.1033 seconds