Spelling suggestions: "subject:"medicamentos detectáveis"" "subject:"medicamentoso detectáveis""
1 |
Avaliação dos medicamentos injetáveis encaminhados ao INCQS no período de janeiro de 2000 a junho de 2006 pelas vigilâncias sanitárias municipais, estaduais e ANVISA / Evaluation of injectable drugs sent to INCQS from january 2000 to june 2006 by municipal and state sanitary surveillance and ANVISASouto, Claudia Ribeiro January 2008 (has links)
Made available in DSpace on 2014-07-28T18:10:47Z (GMT). No. of bitstreams: 2
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
92.pdf: 500261 bytes, checksum: cc3ebc440705580b4bf7b7d8d3035d95 (MD5)
Previous issue date: 2008 / Made available in DSpace on 2014-12-22T16:56:36Z (GMT). No. of bitstreams: 2
92.pdf: 500261 bytes, checksum: cc3ebc440705580b4bf7b7d8d3035d95 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2008 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / O Instituto Nacional de Controle de Qualidade em Saúde (INCQS) - FIOCRUZ é responsável pela realização das análises fiscais de todos os medicamentos injetáveis apreendidos pelas vigilâncias sanitárias estaduais, municipais e ANVISA. Estes medicamentos destinam-se à administração parenteral e são amplamente utilizados. Diante do risco associado ao uso destes medicamentos, o quesito esterilidade torna-se imprescindível, pois a presença de qualquer microrganismo vivo pode ser responsável pela ocorrência de infecções mais sérias. O objetivo deste trabalho é avaliar os medicamentos injetáveis encaminhados ao INCQS no período de janeiro de 2000 a junho de 2006, na modalidade fiscal, advindos da demanda espontânea das vigilâncias sanitárias municipais, estaduais e ANVISA, submetidos ao ensaio de esterilidade. / Background: The National Institute of Quality Control in Health – Fiocruz (INCQS) is responsible for fiscal analysis of all injectable drugs collected by local and federal sanitary surveillance agencies. These drugs are widely prescribed for intravenous use and sterility is paramount, once the presence of any living microorganism can raise the risk of infections. The purpose of this study is to evaluate the injectable drugs process sent to INCQS for fiscal analysis by municipal and state sanitary surveillance and the federal agency, from January 2000 to June 2006, submitted to sterility test. Methods: A survey was conducted using the Sample Management System (SGA). For bivariate analysis, being able for analysis and the final conclusion of the analytical report were considered dependent variables. For categorical variables the respective proportions and confidence intervals of 95% were calculated. Statistical significance was tested by chi-squared test. Data was entered in Epi Info v. 3.3.2 and analysed in SPSS 8.0. Results: Three hundred and sixty injectable drugs were eligible for the study and 297 were analysed. The main reason for not analyzing the remaining 63 drugs was the presence of irregularities in the moment of apprehension. The middle-west region had the best performance, with 95% of the drugs analysed. Thirty-eight drugs (12,8%) were disapproved; the principal reason was the label analysis, mainly from central nervous system drugs. Conclusions: The small proportion of drugs disapproved in the sterility test and in the final analytical report indicates that Brazilian population, except those who live in the North region, is using safe and effective injectable drugs.
|
2 |
Um simulador baseado em realidade virtual para o treinamento de estudantes na administração de medicamentos injetáveisMacedo, Eline Raquel de 11 December 2015 (has links)
Submitted by Fernando Souza (fernandoafsou@gmail.com) on 2017-08-14T13:55:03Z
No. of bitstreams: 1
arquivototal.pdf: 3282966 bytes, checksum: b072b071b37891067b1ce95fac754224 (MD5) / Made available in DSpace on 2017-08-14T13:55:03Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 3282966 bytes, checksum: b072b071b37891067b1ce95fac754224 (MD5)
Previous issue date: 2015-12-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Virtual reality-based simulators can improve health educational processes by adding simulated practice in a safe and realistic environment. A medical procedure which is often target for criticism, due to its error reports, is the administration of injectable drugs. Many researches suggest professional deficiencies in that area. Considering that this deficiency is originated at the formation of the health professional, the main goal of this work is to propose a training tool based on virtual reality for the administration of injectable drugs. Furthermore, this work also presents the modeling of evaluation metrics used on the user evaluation modules by the simulator, discussing the relevance of the establishment of these metrics for use on virtual reality simulators. / Simuladores baseados em realidade virtual podem auxiliar nos processos educacionais em saúde, acrescentando a prática simulada em um ambiente seguro e realista. Um procedimento médico que é alvo de críticas, devido aos relatos de erros, é a administração de medicamentos injetáveis. Várias são as pesquisas que apontam as deficiências dos profissionais nessa técnica. Considerando que essa deficiência venha desde a formação do profissional da saúde, o objetivo principal deste trabalho é propor uma ferramenta de treinamento baseada em realidade virtual para a administração de medicamentos injetáveis. Além disso, este trabalho também apresenta a modelagem das métricas de avaliação utilizadas no módulo para avaliação do usuário pelo simulador, discutindo a importância do estabelecimento dessas métricas para serem utilizadas em simuladores de realidade virtual.
|
3 |
Desenvolvimento de uma metodologia para o controle de qualidade de medicamento injetável, sem violação da ampola, usando espectroscopia NIR e técnicas quimiométricas / Development of a Methodology for Quality Control of Injection Drug, without violation of the ampoule, using NIR spectroscopy and chemometric techniques.Sanches, Fátima Aparecida Castriani 30 November 2009 (has links)
Made available in DSpace on 2015-05-14T13:21:36Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 1804909 bytes, checksum: e1d49807a80dbd1ae8f860dca35fbb15 (MD5)
Previous issue date: 2009-11-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work, a new methodology is proposed that uses a combination of Near Infrared
Spectroscopy (NIR) with chemometric methods of multivariate analysis for the determination of
active ingredient in parenteral drug. The drug used in this study was dipyrone. To create the models
of multivariate calibration, standard samples of dipyrone prepared in laboratory and commercial
samples were used. NIR spectra were recorded, pre-processed and used to build models of pattern
recognition and multivariate calibration. For the initial analysis of data, an exploratory analysis was
performed from PCA models. Then, SIMCA models were developed and used for Screening
analysis of the samples, at a confidence level of 95%. These tests served to confirm which set of
samples (commercial and prepared in the laboratory) could be used in the composition of sets of
calibration, validation and prediction employed in the development of the methodology. For the
selection of samples from the sets we used the SPXY algorithm. Initially, the calibration set
containing commercial and prepared in the laboratory samples was used to build PLS1, MLR-SPA,
SW-MLR, MLR-ASA and MLR-GA multivariate calibration models. These models were validated
using a test set and applied to the determination of dipyrone using a prediction set. The results
showed that all models presented satisfactory prediction errors with respect to the reference method,
and it is very promising for predicting the dipyrone content in drugs injection. As the proposed
methodology uses a non invasive process it is not necessary a previous treatment of the samples, no
reagent was used, and a relatively high analytical rate is achieved. / Neste trabalho, é proposta uma nova metodologia que utiliza a combinação da
espectrometria no infravermelho próximo (NIR) com métodos quimiométricos de
análise multivariada para a determinação do teor de princípio ativo em um medicamento
de uso parenteral. O medicamento utilizado neste estudo foi a dipirona sódica injetável.
Para construção dos modelos de calibração multivariada foram empregadas amostras
padrão de dipirona sódica preparadas no laboratório e amostras comerciais. Os espectros
NIR foram registrados, pré-tratados e utilizados para a construção de modelos de
reconhecimento de padrões e calibração multivariada. Para a análise inicial dos dados,
uma análise exploratória foi realizada a partir de modelos PCA. Em seguida, modelos
SIMCA foram elaborados e utilizados para uma análise Screening das amostras,
empregando um nível de confiança de 95%. Essas análises serviram para constatar que
todas as amostras (comerciais e preparadas no laboratório) poderiam ser utilizadas na
composição dos conjuntos de calibração, validação e predição, empregados no
desenvolvimento da metodologia. Para a seleção das amostras dos conjuntos utilizou-se
o algoritmo SPXY. Inicialmente, o conjunto de calibração contendo amostras comerciais
e as preparadas no laboratório foi empregado na construção de modelos de calibração
multivariada PLS1, MLR-SPA, MLR-SW, MLR-ASA e MLR-GA. Esses modelos foram
validados usando um conjunto de teste e foram aplicados para a determinação do teor de
dipirona usando um conjunto de predição. Os resultados mostraram que todos os
modelos apresentaram erros de previsão satisfatórios com relação ao método de
referência, sendo bastante promissores para a predição do teor de dipirona sódica em
medicamentos injetáveis. Como a metodologia proposta utiliza um processo não
invasivo, não é necessário um tratamento prévio das amostras, nenhum reagente foi
usado, e uma freqüência analítica relativamente elevada de análise é alcançada.
|
4 |
Um fotômetro LED-NIR duplo feixe microcontrolado e portátil para análise screening e quantitativa de medicamentos injetáveis de forma não invasiva / A micro-processor controlled and portable dual-beam LED-NIR photometer for noninvasive quantitative and screen analyses of injectable drugsSanches, Fatima Aparecida Castriani 27 September 2013 (has links)
Made available in DSpace on 2015-05-14T13:21:31Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 4300715 bytes, checksum: 6618808ff4fc3b330190a5a4b7fe14f3 (MD5)
Previous issue date: 2013-09-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work, a portable LED - NIR double beam micro-processor controlled photometer
for non-destructive/non-invasive screening and quantitative analysis of injectable medicines
was developed to assess conformity with values established by the Brazilian Pharmacopoeia.
The product analyzed was injectable dipyrone (1g/2 mL) sold in amber colored vials of 1.1 cm
outer diameter, and 6 cm in height. Initially, spectroscopic studies were carried out employing
a commercial spectrophotometer to assess the best NIR spectrum regions that might be used.
The instrument developed used two twin LEDs with NIR radiation emissions rated at 1050 ±
50 nm. Two InGaAs photodiodes (also identical), and a PIC18F455 microcontroller were used
as well. The output of the instrument used a PIC microcontroller coupled to a 20x2 liquid
crystal display which communicated with a PC by USB 2.0 for communication. The instrument
evaluated commercial dipyrone injection samples using absorbance measurements made
directly from ampoules of the injectable medicines. The photometer was calibrated with
standard solutions of dipyrone, and its performance was evaluated by an analysis of 620 of the
commercial dipyrone injection samples, where 320 were expired. The instrument had a high
success rate for screening analysis (91%). For quantitative determination of the active
dipyrone, a linear response was obtained [R2 = 0.9964, A = 0.0068 + 0.0043 C (% w/v)] in the
concentration range of 5 to 60% m/v. We also obtained a low relative error of 0.40%, and good
accuracy in the analyses with a relative standard deviation of 2.13%. / Neste trabalho foi desenvolvido um fotômetro LED-NIR duplo feixe
microcontrolado e portátil para análise screening e quantitativa de medicamentos
injetáveis de forma não destrutiva/não invasiva, visando investigar a conformidade
desses com os valores estabelecidos na Farmacopéia Brasileira. O medicamento
analisado foi a dipirona sódica injetável 1g/2mL, comercializados em ampolas de
coloração âmbar. Foram realizados inicialmente estudos espectroscópicos empregando
um espectrofotômetro comercial para avaliar quais as melhores regiões do espectro NIR
que poderiam ser empregadas para a determinação da espécie de interesse. O
instrumento desenvolvido utiliza dois LEDs-NIR com emissão de radiação nominal em
1050 ± 50 nm gêmeos (de mesmas especificações técnicas), dois fotodiodos de InGaAs
também idênticos e um microcontrolador PIC18F455. Como dispositivos de saída do
instrumento foram empregados o microcontrolador PIC acoplado a um display de cristal
líquido 20x2, o qual também se comunica com um microcomputador portátil por
comunicação USB 2.0. O instrumento foi avaliado com amostras comerciais de dipirona
sódica injetável por medidas de absorbância efetuadas diretamente nas ampolas dos
medicamentos injetáveis. O fotômetro foi calibrado com soluções padrão de dipirona e
seu desempenho foi avaliado na análise de 620 amostras comerciais de dipirona
injetável, das quais 320 apresentavam prazo de validade expirado. O instrumento obteve
elevado índice de acerto para a análise screening (91%). Para determinação quantitativa
do princípio ativo dipirona, uma resposta linear foi obtida [R2 = 0,9964, A = 0,0068 +
0,0043 C (% m/v)] na faixa de concentração de: 5 a 60 % m/v. Também foi obtido um
baixo erro relativo conjunto (0,40 %) e boa precisão nas análises (desvio padrão relativo
conjunto = 2,13%).
|
Page generated in 0.0889 seconds