• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribuição para a definição de critérios para o dimensionamento da ligação entre peças estruturais de madeira por chapas metálicas com dentes estampados / not available

Carvalho, Johnny Soares de 21 June 2002 (has links)
O crescimento da população urbana, bem como as diferenças sociais brasileiras, têm causado significativa degradação nas condições de vida e de moradia em nosso país. Tal fato vem referenciar a necessidade de se intensificar as pesquisas que tenham como objetivos a produção de alternativas tecnológicas para solucionar-se tais problemas. Não é ainda comum no Brasil o uso de chapas com dentes estampados para se fazer a conexão de peças estruturais de madeira, apesar dessas se apresentarem como uma ótima alternativa estrutural e econômica para tal. A norma brasileira, NBR 7190/97 - Projeto de Estruturas de Madeira, não apresenta um método com os critérios de dimensionamento para tais tipos de ligação. Baseado em estudos teóricos e experimentais desenvolvidos no Laboratório de Madeira e Estruturas de Madeira (LaMEM), do Departamento de Engenharia de Estruturas da Escola de Engenharia de São Carlos, Universidade de São Paulo, são apresentados neste trabalho contribuições para o desenvolvimento de tais critérios para o dimensionamento destas ligações. O presente estudo foi desenvolvido para atender as especificações de espécies tropicais nativas e de reflorestamento encontradas em território nacional. / The increase number of urban population such as the social disparity of Brazilian people has caused significant degradation in habitation life style, increased slum numbers and the number of homeless people. Such fact strengthen the necessity of intensify researches that produce technological alternatives to solve this problems. In Brazil, it is not common see metal plate connectors in roof trusses, in spite of this connectors been a good structural and economical alternative to execute this joints. In Brazilian code, NBR 7190/97 - Timber Structures Design, design criteria for this kind of joints are not yet established. Based on theoretical and experimental studies, carried out in Wood and Timber Structures Laboratory, Structural Engineering Department, São Carlos Engineering School, São Paulo University, in this paper such criteria design will be presented. The study was developed and calibrated to attend the specifications of native specimens of Brazilian tropical wood species.
2

Contribuição para a definição de critérios para o dimensionamento da ligação entre peças estruturais de madeira por chapas metálicas com dentes estampados / not available

Johnny Soares de Carvalho 21 June 2002 (has links)
O crescimento da população urbana, bem como as diferenças sociais brasileiras, têm causado significativa degradação nas condições de vida e de moradia em nosso país. Tal fato vem referenciar a necessidade de se intensificar as pesquisas que tenham como objetivos a produção de alternativas tecnológicas para solucionar-se tais problemas. Não é ainda comum no Brasil o uso de chapas com dentes estampados para se fazer a conexão de peças estruturais de madeira, apesar dessas se apresentarem como uma ótima alternativa estrutural e econômica para tal. A norma brasileira, NBR 7190/97 - Projeto de Estruturas de Madeira, não apresenta um método com os critérios de dimensionamento para tais tipos de ligação. Baseado em estudos teóricos e experimentais desenvolvidos no Laboratório de Madeira e Estruturas de Madeira (LaMEM), do Departamento de Engenharia de Estruturas da Escola de Engenharia de São Carlos, Universidade de São Paulo, são apresentados neste trabalho contribuições para o desenvolvimento de tais critérios para o dimensionamento destas ligações. O presente estudo foi desenvolvido para atender as especificações de espécies tropicais nativas e de reflorestamento encontradas em território nacional. / The increase number of urban population such as the social disparity of Brazilian people has caused significant degradation in habitation life style, increased slum numbers and the number of homeless people. Such fact strengthen the necessity of intensify researches that produce technological alternatives to solve this problems. In Brazil, it is not common see metal plate connectors in roof trusses, in spite of this connectors been a good structural and economical alternative to execute this joints. In Brazilian code, NBR 7190/97 - Timber Structures Design, design criteria for this kind of joints are not yet established. Based on theoretical and experimental studies, carried out in Wood and Timber Structures Laboratory, Structural Engineering Department, São Carlos Engineering School, São Paulo University, in this paper such criteria design will be presented. The study was developed and calibrated to attend the specifications of native specimens of Brazilian tropical wood species.
3

Relationship between Tooth Withdrawal Strength and Specific Gravity for Metal Plate Truss Connections

Via, Brian Kipling 16 July 1998 (has links)
The objectives of this research were twofold: a) to define the relationship between tooth withdrawal and specific gravity for southern pine lumber and four different plate-to-wood load orientations, and b) to demonstrate how these relationships could be applied to new lumber grades to predict tooth withdrawal performance so that additional testing would not be necessary. The four orientations investigated were: a.) LRAA - plate axis parallel to load and wood grain parallel to load. b.) LREA - plate axis perpendicular to load and wood grain parallel to load. c.) LRAE - plate axis parallel to load and wood grain perpendicular to load. d.) LREE - plate axis perpendicular to load and wood grain perpendicular to load. For the LRAA, LREA, LRAE, LREE orientations, the following sample sizes were respectively: 27, 22, 27, and 29. Results showed specific gravity and embedment gap were excellent predictors of ultimate tooth withdrawal stress for the LRAA orientation. However, neither specific gravity nor percentage of latewood significantly influenced the location of tooth withdrawal. For the LREA orientation, specific gravity alone was a good predictor of ultimate tooth withdrawal stress. Furthermore, the side of the joint test specimen where tooth withdrawal initiated was dependent on the wood piece with the lowest mean specific gravity. For the LRAE orientation, specific gravity was a marginal predictor of ultimate tooth withdrawal stress. For the LREE orientation, specific gravity was a decent predictor of ultimate tooth-withdrawal stress. / Master of Science
4

Método de ensaio de ligações de estruturas de madeira por chapas com dentes estampados / Test method for joints of timber structures made with metal plate connector

Baraldi, Lívio Túlio 11 October 1996 (has links)
Este trabalho apresenta uma proposta de método de ensaio para determinação da resistência de ligações em peças estruturais de madeira por chapas com dentes estampados e também verifica os modos de ruptura destas ligações. Para esta finalidade foram realizados ensaios com 5 (cinco) espécies de madeira classificadas de acordo com as classes de resistência apresentadas no projeto da nova norma brasileira para estruturas de madeira, a PNBR 7190/1996 - Projeto de Estruturas de Madeira. No trabalho são verificados 3 (três) modos básicos de ruptura das ligações, a saber: tração da chapa, cisalhamento da chapa e arrancamento dos dentes da chapa da peça de madeira. Dentro de cada modo de ruptura verifica-se os efeitos da variação da posição da chapa em relação à direção de aplicação da força. Determina-se também a resistência da ligação de acordo com o proposto pelo projeto da nova norma brasileira para estruturas de madeira (PNBR 7190, 1996). / The aim of this work is to propose a test method to determine the strength and to verify failure modes of timber joints made with metal connectors plate. To this purpose, several tests were made with 5 species of wood, which were classified according to the strength class introduced in the new Brazilian Standard for Timber Structures, NBR 7190/1996 - Timber Structure Project. In this work are verified 3 failure modes: metal connector plates under shear force and pure tension force, and lateral resistance strength of metal connector plate teeth. For each failure mode is verified the effect of the position of the plate under the direction of force. The resistance of joints are determine in agreement to the new Brazilian Standard for Timber Structures.
5

Método de ensaio de ligações de estruturas de madeira por chapas com dentes estampados / Test method for joints of timber structures made with metal plate connector

Lívio Túlio Baraldi 11 October 1996 (has links)
Este trabalho apresenta uma proposta de método de ensaio para determinação da resistência de ligações em peças estruturais de madeira por chapas com dentes estampados e também verifica os modos de ruptura destas ligações. Para esta finalidade foram realizados ensaios com 5 (cinco) espécies de madeira classificadas de acordo com as classes de resistência apresentadas no projeto da nova norma brasileira para estruturas de madeira, a PNBR 7190/1996 - Projeto de Estruturas de Madeira. No trabalho são verificados 3 (três) modos básicos de ruptura das ligações, a saber: tração da chapa, cisalhamento da chapa e arrancamento dos dentes da chapa da peça de madeira. Dentro de cada modo de ruptura verifica-se os efeitos da variação da posição da chapa em relação à direção de aplicação da força. Determina-se também a resistência da ligação de acordo com o proposto pelo projeto da nova norma brasileira para estruturas de madeira (PNBR 7190, 1996). / The aim of this work is to propose a test method to determine the strength and to verify failure modes of timber joints made with metal connectors plate. To this purpose, several tests were made with 5 species of wood, which were classified according to the strength class introduced in the new Brazilian Standard for Timber Structures, NBR 7190/1996 - Timber Structure Project. In this work are verified 3 failure modes: metal connector plates under shear force and pure tension force, and lateral resistance strength of metal connector plate teeth. For each failure mode is verified the effect of the position of the plate under the direction of force. The resistance of joints are determine in agreement to the new Brazilian Standard for Timber Structures.

Page generated in 0.1787 seconds