1 |
Mixing Performance Evaluation of a Micromixer Utilizing CFD and micro PIV systemTsai, Ming-Feng 03 September 2005 (has links)
This study proposed a novel design of the passive micromixer which employed several quadrilateral shaped blocks in the micro channel to enhance mixing. Both numerical and experimental investigations have been carry out. Commercial software CFD-ACE was used to simulate the flows. The simulation results showed great agreement with the measured results, implying that Navier¡VStokes¡¦ equations still effectively governs the micro-scope flows in this scale. It is effective to enhance mixing efficiency over wide flow rate ranges. Mixing performance was characterized by Laser-induced-fluorescence system (LIF system) to quantity the concentration distribution in the micro channel .
In addition, Microscopic flow visualization was also setup to visualize the flow field in the micro mixer. Micro-particle image velocimetry (Micro-PIV) was used to measure the flow fields in microchannel filled with deionized water (DI water) . The system utilizes an epifluorescent microscope, 3.3 £gm diameter seed particles, and an high speed CCD camera to record particle-image fields. The vector fields are analyzed using a double-frame cross-correlation algorithm. The stochastic influence of Brownian motion plays a significant role in the accuracy of instantaneous velocity measurements.
|
2 |
Design and development of a two dimensional scanning molecular tagging velocimetry (MTV) systemAhmad, Farhan Unknown Date
No description available.
|
3 |
In Vitro Investigation of Cell-Free Layer Formation in Microchannels: Dependency on the Red Blood Cell Aggregation and Field of ShearGliah, Omemah Rajab January 2018 (has links)
Red blood cells (RBCs) form approximately 40 to 45% of the human blood volume, and their behaviour and characteristics are the main determinant of blood properties, such as viscosity. RBCs are deformable species and stack together under low shear rate to form aggregates or rouleaux. Flowing RBCs migrate away from the wall leaving a cell-depleted layer known as the cell-free layer (CFL). This layer contributes to the blood viscosity and exchange between the RBCs and the target cells: a thinner CFL enhances the exchange process by reducing the diffusion distance. The formation of this CFL, however, is not yet completely understood.
The goal of this study is to improve the understanding of the formation of the CFL in the micro-flow. This was accomplished by studying the effects of changing both the flow rate and the microchannel geometry on blood flow in microchannels.
In this work, 10% hematocrit human blood suspensions were prepared in native plasma and flowed through poly-dimethylsiloxane (PDMS) microchannels of 100 μm x 34 μm cross-section. Investigation of the flowing cells was performed by using micro particle image velocimetry (μPIV) coupled with a high-speed camera. First, the high-speed camera images were processed with customized Matlab programs to detect and measure the CFL thickness and the RBC aggregates sizes. Second, the blood flow velocity profiles were measured using μPIV in order to determine the actual flow rate, the RBCs’ centerline velocity, and the shear rate.
The results showed that the increase in both flow rate and shear rate significantly reduced the CFL thickness and RBC aggregates size. Comparison of the upstream and downstream measurements in the bifurcating microchannel showed that the change in microchannel geometry did not significantly influence CFL thickness and RBC aggregate size, while within the daughter branches, RBCs tended to flow close to the inner wall resulting in an undetectable CFL at the inner wall and in a larger CFL at the outer wall of the branch. These in vitro results quantitatively relate CFL thickness and RBC aggregate size at different shear rates. The findings are of immediate interest regarding the understanding of microcirculation and improved designs of microchips.
|
4 |
Flow Visualization In Microfluidic Expansion And MixingYakhshi-Tafti, Ehsan 01 January 2009 (has links)
Micro particle image velocimetry (microPIV) is a non-intrusive tool for visualizing flow in micron-scale conduits. Using this investigative instrument, two experimental studies were performed to understand flow behaviors in microfluidic channels - a sudden expansion step flow and laminar velocity profile variation in diffusion driven mixing. First, flow in a backward facing step feature (1:5 expansion ratio) in a microchannel was taken as the subject of microPIV flow visualization. The onset and development of a recirculation flow was studied as a function of flow rate. This flow pattern was further used to investigate two major parameters affecting microPIV measurements; the depth-of-focus and recording time-intervals between images in a microPIV image pair. The onset of recirculation was initiated at flow rates that correspond to Reynolds numbers, Re > 95, which is well beyond the typical working range of microfluidic devices (Re=0.01-10). The recirculation flow has a 3D structure due to the dimensions of the microchannel and the effect of no slip condition on the walls. Ensemble cross-correlation was found not to be sensitive to variations of depth-of-focus and the output flow fields were similar as long as the overall optical focus remained within the upper and lower bounds of the microchannel. However, variations of time intervals between images in a microPIV pair, resulted in quantitatively and qualitatively different flow patterns for a given constant flow rate and depth-of-focus. In the second experiment, the effect of the laminar velocity profile and its variation on mixing phenomena at the reduced scale is studied. It is shown that the diffusive mass flux between two miscible streams, flowing in a laminar regime in a microchannel, is enhanced if the velocity at their diffusion interface is increased. Based on this idea, an in-plane passive micromixing concept is proposed and implemented in a working device (sigma micromixer). This mixer shows considerable mixing performance by periodically varying the flow velocity profile, such that the maximum of the profile coincides with the transversely progressing diffusion fronts repeatedly throughout the mixing channel. microPIV has been used to visualize the behavior of laminar flow inside the micromixer device and to confirm the periodic variation of the velocity profile through the mixing channel.
|
5 |
<b>Defocused Distance Prediction in 3D Particle Tracking</b>Baoxuan Tao (18858733) 22 June 2024 (has links)
<p dir="ltr">Particle tracking velocimetry, also known as PTV, is a technology to measure velocity and study the flow field in fluid by observing change in position of individual tracer particles over time. A laser sheet illuminates a thin layer of the sample, in which particles emit fluorescent light and are visible to the camera. Particles at different distances from the microscope lens focal plane are visible, because particle diameter is much smaller than the thickness of laser sheet in micro-scale. The defocused distance changes the shape of particle seen by the camera. Analyzing particle shapes and obtaining the defocused distance of particles completes the third dimension of PTV with the use of a single camera. One approach to obtain defocused distance from particle shape is by comparing particle shapes with calibration images of known defocused distance. The accuracy of PTV relies on the collection of proper calibration images. There are three methods involved in this work. The first approach is to use synthetic images generated by solving Lommel differential equations, which describe the intensity distribution of particles under the impact of defocusing aberration. It was later discovered that the point source assumption inherent in Lommel function causes inaccuracy in generated calibration images. The second approach captures particle images while manually shifting the microscope stage in the z-direction. This approach causes systematic error by ignoring the refractive index of the immersion medium. The third approach is to use a microscale reference ramp as calibration target. Results are experimentally compared with particle shapes obtained from pressure driven flow with known velocity profile.</p>
|
6 |
[en] VISCOELASTIC FLOW THROUGH MICROCHANNELS WITH CONSTRICTION / [pt] ESCOAMENTO VISCOELÁSTICO ATRAVÉS DE MICROCANAIS COM CONSTRIÇÃOJOSE ANGEL FLORIAN GUTIERREZ 28 February 2019 (has links)
[pt] Alguns projetos pilotos de injeção de polímeros em campos de produção de petróleo mostraram um incremento na recuperação de óleo, embora os mecanismos que governam a dinâmica do escoamento não são bem compreendidos. Recentes investigações experimentais mostraram que as propriedades viscoelásticas de soluções poliméricas podem alterar o comportamento do escoamento na escala de poros e reduzir a saturação residual de óleo. Para entender esses fenômenos em meios porosos, é importante estudar o escoamento de soluções viscoelásticas através das gargantas dos poros. Este trabalho apresenta um estudo experimental do escoamento de uma solução viscoelástica de PEO (0,1 porcento em peso de óxido de polietileno) de alto peso molecular escoando através de uma constrição, utilizado como modelo de uma geometria de garganta de poro de um meio poroso. Medições de queda de pressão e campos de velocidade do escoamento são obtidos utilizando a técnica de velocimetria por imagem de partículas (Micro-PIV). Experimentos com uma solução viscosa de glicerina (45 porcento em peso de glicerina em
água) de viscosidade similar à solução de PEO foram também realizados com a finalidade de estimar os efeitos elásticos da solução de PEO. O escoamento da solução de PEO exibiu uma queda de pressão extra (comportamento não linear) acima de uma condição crítica do escoamento, acima da qual os efeitos elásticos passam a ser preponderantes. Para toda a faixa de vazão explorada, os campos de velocidade da solução de glicerina mostraram um regime de escoamento Newtoniano, enquanto a solução de PEO apresenta instabilidade no escoamento a partir de um número de Weissenberg crítico, coincidindo com o aumento da queda de pressão. Esta instabilidade pode ser relacionada ao aumento da viscosidade extensional na entrada da garganta acima de uma determinada taxa de extensão. Os resultados obtidos indicam a variação do padrão do escoamento da solução polimérica de PEO devido à presença dos efeitos elásticos do polímero, e fornecem informações importantes sobre o comportamento das soluções poliméricas viscoelásticas em um meio poroso e que podem impactar sua utilização na recuperação melhorada de óleo. / [en] Some pilot projects of polymer injection in oil fiel ds have shown an increase in oil recovery, although the mechanisms that govern the flow dynamics are still not well understood. Recent experimental investigations have shown that the viscoelastic properties of polymer solutions may change the pore-scale flow behavior and reduce the residual oil saturation. To understand these phenomena in porous media, it is important to understand viscoelastic flow behavior through the pores-throats. This work presents experimental study of the flow of a high molecular viscoelastic PEO solution (0.1 wt percent Polyethylene Oxide) flowing through a constricted capillary, used as model for a pore-throat geometry of a porous media. Pressure drop measurements are performed and velocity fields are obtained using the micro-particle image velocimetry (Micro-PIV) technique. Experiments with a viscous solution of glycerin (45 wt percent glycerin in water), of similar shear viscosity to the PEO solution were also performed in order to isolate the elastic effects of the PEO solution. The flow of the PEO solution exhibited an extra pressure drop (nonlinear behavior) above a critical flow condition beyond which the elastic forces become relevant. For the entire flow rate range explored, the velocity field of the glycerin solution showed a Newtonian flow regime, while the PEO solution shows instability in the flow above a critical Weissenberg number, coinciding with the onset of the extra pressure drop. This instability in the flow is associated with the high extensional viscosity near the constriction at high enough extension rates. The results show the changes in the flow pattern of the PEO polymer solution due to the presence of the elastic effects of polymer, and provide important information on how viscoelastic polymer solutions behave in a porous media and can impact their use in Enhanced Oil Recovery operations.
|
7 |
Micro-PIV Study Of Apparent Slip Of Water On Hydrophobic SurfacesAsthana, Ashish 01 July 2008 (has links)
The condition of no relative velocity of fluid past solid is termed as ‘no-slip boundary condition’. This condition is a general observation in fluid mechanics. However, several research groups have recently reported slip of water for surfaces with water repelling chemistry (referred to as hydrophobic surfaces). The effect has been attributed to disruption of H-bonding network of water molecules at such surfaces and resulting nucleation of dissolved gases and even reduced water density locally in absence of dissolved air. Slip of water on hydrophobic surfaces has been demonstrated to get amplified by high degree of roughness and patterning. Trapping of air in the surface asperities has been cited as the possible reason. The present work focuses on the study of effect of surface chemistry and roughness on flow behavior close to solid surfaces.
Superhydrophobic surfaces have been generated by novel methods and wet-etching has been used to generate well-defined patterns on silicon surfaces. For flow characterisation, a micrometre resolution Particle Image Velocimetry (micro-PIV) facility has been developed and flow measurements have been carried out with a spatial resolution of less than 4 µm.
It has been found from the experiments that flow of water on smooth surfaces, with or without chemical modification, conforms to the no-slip within the resolution limits of experiments. Deviation is observed in case of rough and patterned hydrophobic surfaces, possibly because of trapped air in asperities. Total Internal Reflection experiments, used to visualise the air pockets, confirmed the trapping of air at asperities. Diffusion of air out of the crevices seems to be the limiting factor for the utility of these surfaces in under-water applications.
|