• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • 2
  • Tagged with
  • 13
  • 13
  • 6
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dna electrophoresis in photopolymerized polyacrylamide gels on a microfluidic device

Lo, Chih-Cheng 15 May 2009 (has links)
DNA gel electrophoresis is a critical analytical step in a wide spectrum of genomic analysis assays. Great efforts have been directed to the development of miniaturized microfluidic systems (“lab-on-a-chip” systems) to perform low-cost, high-throughput DNA gel electrophoresis. However, further progress toward dramatic improvements of separation performance over ultra-short distances requires a much more detailed understanding of the physics of DNA migration in the sieving gel matrix than is currently available in literature. The ultimate goal would be the ability to quantitatively determine the achievable level of separation performance by direct measurements of fundamental parameters (mobility, diffusion, and dispersion coefficients) associated with the gel matrix instead of the traditional trial-and-error process. We successfully established this predicting capability by measuring these fundamental parameters on a conventional slab gel DNA sequencer. However, it is difficult to carry out fast and extensive measurements of these parameters on a conventional gel electrophoresis system using single-point detection (2,000 hours on the slab gel DNA sequencer we used). To address this issue, we designed and built a new automated whole-gel scanning detection system for a systematic investigation of these governing parameters on a microfluidic gel electrophoresis device with integrated on-chip electrodes, heaters, and temperature sensors. With this system, we can observe the progress of DNA separation along the whole microchannel with high temporal and spatial accuracy in nearly real time. This is in contrast to both conventional slab gel imaging where the entire gel can be monitored, but only at one time frame after completion of the separation, and capillary electrophoresis systems that allows detection as a function of time, but only at a single detection location. With this system, a complete set of mobility, diffusion, and dispersion data can be collected within one hour instead of days or even months of work on a conventional sequencer under the same experimental conditions. The ability to acquire both spatial and temporal data simultaneously provides a more detailed picture of the separation process that can potentially be used to refine theoretical models and improve separation performance over ultra-short distances for the nextgeneration of electrophoresis technology.
2

Studies on High Performance Microscale Electrophoresis Using Online Sample Concentration Techniques / オンライン試料濃縮法を用いる高性能ミクロスケール電気泳動に関する研究

Kawai, Takayuki 26 March 2012 (has links)
Kyoto University (京都大学) / 0048 / 新制・課程博士 / 博士(工学) / 甲第16864号 / 工博第3585号 / 新制||工||1542(附属図書館) / 29539 / 京都大学大学院工学研究科材料化学専攻 / (主査)教授 大塚 浩二, 教授 松原 誠二郎, 教授 田中 勝久 / 学位規則第4条第1項該当
3

Immunoassays of Potential Cancer Biomarkers in Microfluidic Devices

Pagaduan, Jayson Virola 30 March 2015 (has links) (PDF)
Laboratory test results are important in making decisions regarding a patient's diagnosis and response to treatment. These tests often measure the biomarkers found in biological fluids such blood, urine, and saliva. Immunoassay is one type of laboratory test used to measure the level of biomarkers using specific antibodies. Microfluidics offer several advantages such as speed, small sample volume requirement, portability, integration, and automation. These advantages are motivating to develop microfluidic platforms of conventional laboratory tests. I have fabricated polymer microfluidic devices and developed immunoassays on-chip for potential cancer markers. Silicon template devices were fabricated using standard photolithographic techniques. The template design was transferred to a poly(methyl methacrylate) (PMMA) piece by hot embossing and subsequently bonded to another PMMA piece with holes for reservoirs. I used these devices to perform microchip immunoaffinity electrophoresis to detect purified recombinant thymidine kinase 1 (TK1). Buffer with 1% methylcellulose acted as a dynamic coating that minimized nonspecific adsorption of protein and as sieving matrix that enabled separation of free antibody from antibody-TK1 complexes. Using this technique, I was able to detect TK1 concentration >80 nM and obtained separation results within 1 minute using a 5 mm effective separation length. Detection of endogenous TK1 in serum is difficult because TK1 is present at the pM range. I compared three different depletion methods to eliminate high abundance immunoglobulin and human serum albumin. Cibacron blue columns depleted abundant protein but also nonspecifically bound TK1. I found that ammonium sulfate precipitation and IgG/albumin immunoaffinity columns effectively depleted high abundance proteins. TK1 was salted out of the serum with saturated ammonium sulfate and still maintained activity. To integrate affinity columns in microfluidic devices, I have developed a fast and easy strategy for initial optimization of monolith affinity columns using bulk polymerization of multiple monolith solutions. The morphology, surface area, and porosity, were qualitatively assessed using scanning electron microscopy. This method decreased the time, effort, and resources compared to in situ optimization of monoliths in microfluidic devices. This strategy could be used when designing novel formulations of monolith columns. I have also integrated poly(ethylene glycol dimethacrylate-glycidyl methacrylate) monolith affinity columns in polymer microfluidic devices to demonstrate the feasibility of extracting human interleukin 8 (IL8), a cancer biomarker, from saliva. Initial results have shown that the affinity column (~3 mm) was successfully integrated into the devices without prior surface modification. Furthermore, anti-IL8 was immobilized on the surface of the monolith. Electrochromatograms showed that 1 ng/mL of IL8 can be detected when in buffer while 10 ng/mL was detected when IL8 was spiked in saliva. Overall, these findings can be used to further develop immunoassays in microfluidic platforms, especially for analyzing biological fluids.
4

Design, Fabrication, and Optimization of Miniaturized Devices for Bioanalytical Applications

Kumar, Suresh 01 August 2015 (has links)
My dissertation work integrates the techniques of microfabrication, micro/nanofluidics, and bioanalytical chemistry to develop miniaturized devices for healthcare applications. Semiconductor processing techniques including photolithography, physical and chemical vapor deposition, and wet etching are used to build these devices in silicon and polymeric materials. On-chip micro-/nanochannels, pumps, and valves are used to manipulate the flow of fluid in these devices. Analytical techniques such as size-based filtration, solid-phase extraction (SPE), sample enrichment, on-chip labeling, microchip electrophoresis (µCE), and laser induced fluorescence (LIF) are utilized to analyze biomolecules. Such miniaturized devices offer the advantages of rapid analysis, low cost, and lab-on-a-chip scale integration that can potentially be used for point-of-care applications.The first project involves construction of sieving devices on a silicon substrate, which can separate sub-100-nm biostructures based on their size. Devices consist of an array of 200 parallel nanochannels with a height step in each channel, an injection reservoir, and a waste reservoir. Height steps are used to sieve the protein mixture based on size as the protein solution flows through channels via capillary action. Proteins smaller than the height step reach the end of the channels while larger proteins stop at the height step, resulting in separation. A process is optimized to fabricate 10-100 nm tall channels with improved reliability and shorter fabrication time. Furthermore, a protocol is developed to reduce the electrostatic interaction between proteins and channel walls, which allows the study of size-selective trapping of five proteins in this system. The effects of protein size and concentration on protein trapping behavior are evaluated. A model is also developed to predict the trapping behavior of different size proteins in these devices. Additionally, the influence of buffer ionic strength, which can change the effective cross-sectional area of nanochannels and trapping of proteins at height steps, is explored in nanochannels. The ionic strength inversely correlates with electric double layer thickness. Overall, this work lays a foundation for developing nanofluidic-based sieving systems with potential applications in lipoprotein fractionation, protein aggregate studies in biopharmaceuticals, and protein preconcentration. The second project focuses on designing and developing a microfluidic-based platform for preterm birth (PTB) diagnosis. PTB is a pregnancy complication that involves delivery before 37 weeks of gestation, and causes many newborn deaths and illnesses worldwide. Several serum PTB biomarkers have recently been identified, including three peptides and six proteins. To provide rapid analysis of these PTB biomarkers, an integrated SPE and µCE device is assembled that provides sample enrichment, on-chip labeling, and separation. The integrated device is a multi-layer structure consisting of polydimethylsiloxane valves with a peristaltic pump, and a porous polymer monolith in a thermoplastic layer. The valves and pump are fabricated using soft lithography to enable pressure-based sample actuation, as an alternative to electrokinetic operation. Porous monolithic columns are synthesized in the SPE unit using UV photopolymerization of a mixture consisting of monomer, cross-linker, photoinitiator, and various porogens. The hydrophobic surface and porous structure of the monolith allow both protein retention and easy flow. I have optimized the conditions for ferritin retention, on-chip labelling, elution, and µCE in a pressure-actuated device. Overall functionality of the integrated device in terms of pressure-controlled flow, protein retention/elution, and on-chip labelling and separation is demonstrated using a PTB biomarker (ferritin). Moreover, I have developed a µCE protocol to separate four PTB biomarkers, including three peptides and one protein. In the future, an immunoaffinity extraction unit will be integrated with SPE and µCE to enable rapid, on-chip analysis of PTB biomarkers. This integrated system can be used to analyze other disease biomarkers as well.
5

New Approaches to Stabilize Black Lipid Membranes - Towards Ion Channel Functionalized Detectors for Capillary Separations

Bright, Leonard Kofi January 2015 (has links)
Capillary electrophoresis (CE) is an excellent analytical separation method with promising features such as small sample volumes (µL to pL), fast analysis times (s), high selectivity and efficiency, and excellent compatibility with biological samples. However, the inability of conventional CE detectors to sense biologically active compounds that are optically and electrochemically inactive limits their use for biosensing and drug screening. We have developed a highly stable electrophysiological detection platform consisting of ion channel (IC) reconstituted in synthetic bilayer membrane also known as black lipid membranes (BLM) suspended across a functionalized microaperture to be coupled to a high resolution capillary separation channel. Low energy surface modifiers were used to drastically improve the electrical, mechanical, and temporal stability of BLMs. Glass microapertures modified using tridecafluoro 1, 1, 2, 2-tetrahydrodimethylchlorosilane facilitated the rapid formation of highly stable BLMs due to the amphiphobic property (H₂O/oil repellency). Furthermore, a combination of chemically modified aperture surfaces and chemical cross-linking within the lipid membrane were used to dramatically improve BLM stability. Partial cross-linking within the bilayer maintained fluidity which allowed reconstitution of ion channel proteins while maintaining the stability of BLM-IC platform. The stable BLM-IC across glass pipette aperture was coupled to microchip electrophoresis and was shown to withstand field strength (>250 V/cm) from separation channel. Additionally, planar microapertures fabricated in SU8 were used for the formation of stable BLM-IC platform towards the construction of an integrated device. The chemical properties of the SU8 supported the formation and cross-linking within polymerizable lipid or lipid bilayer doped with polymerizable methacrylate monomers. Additionally, we expressed ion channel coupled receptor fusion protein in HEK 293 cells towards the development of ion channel sensors for wide range of ligand detection in BLM sensor platforms. The pharmacology of IC functionalized with muscarinic acetyl choline (M2-K) receptor using cell based assay by patch clamp electrophysiology showed activation by acetylcholine and inhibition by atropine. Thus this platform holds a great promise as the next-generation integrated analysis system for rapid screening of biologically active compounds (eg. glucagon) in complex matrix such as whole blood and urine for the diagnosis and management of chronic disease such as diabetes.
6

Design, Development, Characterization, and Validation of A Paper-based Microchip Electrophoresis System

Hasan, Muhammad Noman 01 June 2020 (has links)
No description available.
7

Optimization of Nonadsorptive Polymerized Polyethylene Glycol Diacrylate as a Material for Microfluidics and Sensor Integration

Rogers, Chad 01 March 2015 (has links) (PDF)
Microfluidics is a continually growing field covering a wide range of applications, such as cellular analysis, biomarker quantification, and drug discovery; but in spite of this, the field of microfluidics remains predominately academic. New materials are pivotal in providing tailored properties to improve device integration and decrease prototype turnaround times. In biosensing, nonspecific adsorption in microfluidic systems can deplete target molecules in solution and prevent analytes, especially those at low concentrations, from reaching the detector. Polyethylene glycol diacrylate (PEGDA) mixed with photoinitiator forms, on exposure to ultraviolet (UV) radiation, a polymer with inherent resistance to nonspecific adsorption. Optimization of the polymerized PEGDA (poly-PEGDA) formula imbues this material with some of the same properties, including optical clarity, water stability, and low background fluorescence, that makes polydimethylsiloxane (PDMS) a widely used material for microfluidics. Poly-PEGDA demonstrates less nonspecific adsorption than PDMS over a range of concentrations of flowing fluorescently tagged bovine serum albumin solutions, and poly-PEGDA has greater resistance to permeation by small hydrophobic molecules than PDMS. Poly-PEGDA also exhibits long-term (hour scale) resistance to nonspecific adsorption compared to PDMS when exposed to a low (1 μg/mL) concentration of a model adsorptive protein. Electrophoretic separations of amino acids and proteins resulted in symmetrical peaks and theoretical plate counts as high as 4 × 105/m. Pneumatically actuated, non-elastomeric membrane valves fabricated from poly-PEGDA have been characterized for temporal response, valve closure, and long-term durability. A ∼100 ms valve opening time and a ∼20 ms closure time offer valve operation as fast as 8 Hz with potential for further improvement. Comparison of circular and rectangular valve geometries indicates that the surface area for membrane interaction in the valve region is important for valve performance. After initial fabrication, the fluid pressure required to open a closed circular valve is ∼50 kPa higher than the control pressure holding the valve closed. However, after ∼1000 actuations to reconfigure polymer chains and increase elasticity in the membrane, the fluid pressure required to open a valve becomes the same as the control pressure holding the valve closed. After these initial conditioning actuations, poly-PEGDA valves show considerable robustness with no change in effective operation after 115,000 actuations.Often, localized areas of surface functionalization are desired in biosensing, necessitating site-specific derivatization. Integration of poly-PEGDA with different substrates, such as glass, silicon, or electrode-patterned materials, allows for broad application in biosensing and microfluidic devices. Deposition of 3-(trimethoxysilyl) propyl methacrylate or (3-acryloxypropyl) dimethylmethoxysilane onto these substrates makes bonding to poly-PEGDA possible under UV exposure. Primary deposition of (3-acryloxypropyl) dimethylmethoxysilane, followed by photolithographic patterning, allows for silane removal through HF surface etching in the exposed areas and subsequent deposition of 3 aminopropyldiisopropylethoxysilane on the etched regions. Fluorescent probes are used to evaluate surface attachment methods. Primary attachment via reaction of Alexa Fluor 488 TFP ester to the patterned aminosilane demonstrates excellent fluorescent signal. Initial results with glutaraldehyde were demonstrated but require more optimization before this method for secondary attachment is viable. Fabrication of 3D printed microfluidic devices with integrated membrane-based valves is performed with a low-cost, commercially available stereolithographic 3D printer and a custom PEGDA resin formulation tailored for low non-specific protein adsorption. Horizontal microfluidic channels with designed rectangular cross sectional dimensions as small as 350 µm wide and 250 µm tall are printed with 100% yield, as are cylindrical vertical microfluidic channels with 350 µm designed (210 µm actual) diameters. Valves are fabricated with a membrane consisting of a single build layer. The fluid pressure required to open a closed valve is the same as the control pressure holding the valve closed. 3D printed valves are successfully demonstrated for up to 800 actuations. Poly-PEGDA is a versatile material for microfluidic applications ranging from electrophoretic separations, valve implementation, and heterogeneous material integration. Further improvements in PEGDA resin formulation, in combination with a UV source 3D printer, will provide poly-PEGDA devices that are not only rapidly fabricated (<40 min per device), but that also include pumps and valves and are usable with a variety of detection methods, such as laser-induced fluorescence and immunoassays, for broad application in biosensing.
8

3D Printed Microfluidic Devices for Bioanalysis

Beauchamp, Michael J 01 July 2019 (has links)
This work presents the development of 3D printed microfluidic devices and their application to microchip analysis. Initial work was focused on the development of the printer resin as well as the development of the general rules for resolution that can be achieved with stereolithographic 3D printing. The next stage of this work involved the characterization of the printer with a variety of interior and exterior resolution features. I found that the minimum positive and negative feature sizes were about 20 μm in either case. Additionally, micropillar arrays were printed with pillar diameters as small as 16 μm. To demonstrate one possible application of these small resolution features I created microfluidic bead traps capable of capturing 25 μm polystyrene particles as a step toward capturing cells. A second application which I pioneered was the creation of devices for microchip electrophoresis. I separated 3 preterm birth biomarkers with good resolution (2.1) and efficiency (3600 plates), comparable to what has been achieved in conventionally fabricated devices. Lastly, I have applied some of the unique capabilities of our 3D printer to a variety of other device applications through collaborative projects. I have created microchips with a natural masking monolith polymerization window, spiral electrodes for capacitively coupled contactless conductivity detection, and a removable electrode insert chip. This work demonstrates the ability to 3D print microfluidic structures and their application to a variety of analyses.
9

Electrokinetically Operated Integrated Microfluidic Devices for Preterm Birth Biomarker Analysis

Sonker, Mukul 01 August 2017 (has links)
Microfluidics is a vibrant and expanding field that has the potential for solving many analytical challenges. Microfluidics shows promise to provide rapid, inexpensive, efficient, and portable diagnostic solutions that can be used in resource-limited settings. Microfluidic devices have gained immense interest as diagnostic tools for various diseases through biomarker analysis. My dissertation work focuses on developing electrokinetically operated integrated microfluidic devices for the analysis of biomarkers indicative of preterm birth risk. Preterm birth (PTB), a birth prior to 37 weeks of gestation, is the most common complication of pregnancy and the leading cause of neonatal deaths and newborn illnesses. In this dissertation, I have designed, fabricated and developed several microfluidic devices that integrate various sample preparation processes like immunoaffinity extraction, preconcentration, fluorescent labeling, and electrophoretic separation of biomarkers indicative of PTB risk. I developed microchip electrophoresis devices for separation of selected PTB biomarkers. I further optimized multiple reversed-phase porous polymer monoliths UV-polymerized in microfluidic device channels for selective retention and elution of fluorescent dyes and PTB biomarkers to facilitate on-chip labeling. Successful on-chip fluorescent labeling of multiple PTB biomarkers was reported using these microfluidic devices. These devices were further developed using a pH-mediated approach for solid-phase extraction, resulting in a ~50 fold enrichment of a PTB biomarker. Additionally, this approach was integrated with microchip electrophoresis to develop a combined enrichment and separation device that yielded 15-fold preconcentration for a PTB peptide. I also developed an immunoaffinity extraction device for analyzing PTB biomarkers directly from a human serum matrix. A glycidyl methacrylate monolith was characterized within microfluidic channels for immobilization of antibodies to PTB biomarkers. Antibody immobilization and captured analyte elution protocols were optimized for these monoliths, and two PTB biomarker proteins were successfully extracted using these devices. This approach was also integrated with microchip electrophoresis for combined extraction and separation of two PTB biomarkers in spiked human serum in <30 min. In the future, these optimized microfluidic components can be integrated into a single platform for automated immunoaffinity extraction, preconcentration, fluorescent labeling, and separation of PTB biomarkers. This integrated microfluidic platform could significantly improve human health by providing early diagnosis of PTBs.
10

Developing 3D Printed Integrated Microfluidic Devices for Microchip Electrophoresis Separation of Preterm Birth Biomarkers

Esene, Joule E. 06 November 2023 (has links) (PDF)
Preterm birth is a global health challenge and the leading cause of neonatal mortality. Each year, about 15 million babies are born preterm globally. Traditional tools that have been exploited for the detection of preterm birth biomarkers are expensive, time consuming, or lack multiplexing capabilities. The work described in this dissertation highlights techniques developed to detect preterm birth biomarkers rapidly and accurately in the effort to mitigate preterm birth risk. In this dissertation, I first demonstrated the use of stereolithography digital light processing-based 3D printing and microfluidics for the development of microfluidic devices that had microvalves for fluid control. I then used these devices for microchip electrophoresis and fluorescence detection of five preterm birth biomarkers from a published panel. Next, I presented developments in 3D printed microchip electrophoresis device design. I separated amino acids and preterm birth biomarkers in a serpentine device design, obtaining good resolution, separation efficiency, and improved preterm birth biomarker peak capacity. Finally, I demonstrated the integration of solid-phase extraction with microchip electrophoresis in 3D printed microfluidic devices. These integrated devices enabled a seamless transition from preterm birth biomarker enrichment and labeling to microchip electrophoresis separation and fluorescence detection. The work described in this dissertation shows promise in advancing key tools needed to address preterm birth risk rapidly and effectively.

Page generated in 0.0973 seconds