Spelling suggestions: "subject:"microextraction by packed sorbent"" "subject:"microextractions by packed sorbent""
1 |
Towards more selective sorbents for extraction of drugs and biomarkers from biological fluids using molecularly imprinted polymersMoein, Mohammad Mahdi January 2014 (has links)
Sample preparation has a critical role as a first step in analytical processes, especially in bioanalysis and environmental analysis. A good sample preparation technique should be robust and stable, regardless of the sample matrix. The aim of this thesis is to design and synthesize molecularly imprinted polymers that can be used in various sample preparation techniques, such as on-line MEPS, on-line SPE and on-line monolithic pre-columns used for the extraction of drugs, hormones, and cancer biomarkers from human plasma and urine samples. Additional aim was to provide full automation, on-line coupling, short sample preparation time and high-throughput. In this thesis MIP in MEPS was used on-line with liquid chromatography-tandem mass spectrometry (LC/MS/MS) for the determination of sarcosine in human urine and plasma samples. The method was fully automated and the packed sorbent could be used for about hundred extractions. In additional work a coated needle with MIP-Sol-Gel as thin layer was prepared and used for the microextraction of bilirubin from human plasma and urine. Small sample volumes could be handled and the validation of the method showed that the method was robust and selective. In a further work MIP-SPE on-line with HPLC was used for the extraction and determination of dextromethorphan in human plasma samples. MIP-SPE showed a good selectivity and high recovery (87% - 92%). On-line MIP monolithic pre-column was prepared and used in a coupled system for the extraction of tramadol in human plasma and urine samples. The MIP monolithic pre-column showed good selectivity and high extraction recovery was obtained (91-96%). The extraction and analysis of human insulin in plasma and pharmaceutical formulation solutions were carried out using MIP-SPE on-line with HPLC. The validation of the method showed that the method was accurate and robust. / <p>At the time of the doctoral defense, the following paper was unpublished and had a status as follows: Paper 5: Submitted.</p>
|
2 |
Desenvolvimento de fases monolíticas de sílica híbrida para microextração em sorvente empacotado (MEPS) de fármacos em amostras de plasma e análise por cromatografia líquida acoplada a espectrometria de massas em tandem (LC-MS/MS) / Synthesis of hybrid silica monoliths for microextraction by packed sorbent (MEPS) to determine drugs from plasma samples by liquid chromatography-tandem mass (LC-MS/MS)Souza, Israel Donizéti de 27 July 2015 (has links)
Segundo a Organização Mundial da Saúde (OMS), a esquizofrenia é reconhecida como um transtorno neuropsiquiátrico grave que afeta mais de 21 milhões de pessoas em todo o mundo. Para diminuir os sintomas associados a esta doença, a maioria dos pacientes esquizofrênicos fazem uso concomitantemente de antipsicóticos, antidepressivos, ansiolíticos e anticonvulsivantes. O desenvolvimento de métodos analíticos para a determinação desses fármacos em fluidos biológicos é importante para ajustar as doses administradas, minimizar os efeitos adversos e verificar a anuência do paciente à terapia. A química analítica moderna tem se direcionado para a simplificação, através da miniaturização dos sistemas analíticos. Neste contexto, pode-se destacar a técnica de microextração em sorvente empacotado (MEPS). O desenvolvimento de novas fases extratoras para MEPS, como, os monolitos de sílica híbrida permitem pré-concentração seletiva dos analitos. Neste projeto monolitos de sílica híbrida funcionalizados com grupos aminopropil ou cianopropil foram sintetizados pelo processo sol-gel. Estes monolitos apresentaram estrutura contínua, uniforme e porosa, como evidenciado pelas imagens de microscopia eletrônica de varredura (MEV). As análises de espectroscopia vibracional na região do infravermelho por transformada de Fourier (FTIR) dos monolitos de sílica híbrida exibiram picos facilmente identificáveis, característicos dos grupos cianopropil e aminopropil. Estes monolitos foram avaliados como fase estacionária para a MEPS para a determinação de fármacos em amostras de plasma por cromatografia líquida acoplada a espectrometria de massa em Tandem (LC-MS/MS). As variáveis MEPS (influência do pH na sorção dos analitos, número de ciclos aspirar/dispensar, etapa de limpeza do sorvente e solvente de eluição) foram otimizadas para aumentar a eficiência da extração. Em comparação com a fase de sílica híbrida aminopropil, a fase de sílica híbrida cianopropil apresentou maior capacidade de sorção para os fármacos em estudo. O método desenvolvido, MEPS/LC-MS/MS, empregando a fase extratora de sílica híbrida cianopropil, apresentou linearidade adequada com concentrações que variaram desde o limite inferior de quantificação (0,05-1,00 ng.mL-1) até o limite superior de quantificação (40-10.500 ng.mL-1) com coeficientes de determinação (R2) maiores do que 0,9955. Este método apresentou precisão com coeficientes de variação (CV) inferiores a 14% e exatidão com erro padrão relativo (EPR) de -12 a 14%. O método MEPS/LC-MS/MS foi aplicado com êxito para análise simultânea de cinco antipsicóticos (olanzapina, quetiapina, clozapina, haloperidol e clorpromazina), em combinação com sete antidepressivos (mirtazapina, paroxetina, citalopram, sertralina, imipramina, clomipramina e fluoxetina), dois anticonvulsivantes (carbamazepina e lamotrigina) e dois ansiolíticos (diazepam e clonazepam) em amostras de plasma de pacientes esquizofrênicos para fins de monitorização terapêutica. / According to World Health Organization (WHO), schizophrenia is recognizably a devastating neuropsychiatric disorder that affects more than 21 million people worldwide. To lessen the symptoms associated with the disease, most schizophrenic patients use other classes of drugs such as antidepressants, anxiolytics, and anticonvulsants concomitantly with antipsychotics. Developing analytical methods to quantify these drugs in biological fluids is important in therapeutic drug monitoring (TDM) to adjust doses, minimize adverse effects, and check patient adherence to the therapy. Regarding miniaturization and automation, microextraction by packed sorbent (MEPS) is a promising sample preparation technique. Sample preparation of biological matrixes is an important step in analytical processes: it removes endogenous components from the sample and pre-concentrates trace-level analytes. The development of new phases for MEPS such as the hybrid silica monoliths allows selective pre-concentration of the analytes. The present study reports on the synthesis of two hybrid silica monoliths functionalized with aminopropyl or cyanopropyl groups by the solgel process; evaluates these monoliths as selective stationary phase for MEPS to determine drugs in plasma samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS); and discusses important factors (influence of pH on the sorption of analytes, number of draw/eject cycles, washing step, and elution solvent) related to the optimization of MEPS efficiency. The prepared hybrid silica monoliths consisted of a uniform, porous, and continuous silica monolithic network, as shown by scanning electron microscopy (MEV) images. The Fourier-transform infrared spectroscopy (FTIR) spectra of the hybrid silica monoliths displayed readily identifiable peaks, characteristic of the cyanopropyl and aminopropyl groups. Compared with the aminopropyl hybrid silica phase, the cyanopropyl hybrid silica phase exhibited higher binding capacity for most of the target drugs. The developed method, MEPS/LC-MS/MS, afforded adequate linearity at concentrations ranging from the lower limit of quantification (0.05 to 1.00 ng.mL-1) to the upper limit of quantification (40 to 10500 ng.mL-1); the coefficients of determination (R2) were higher than 0.9955. The precision of the method presented coefficients of variation (CV) lower than 14%; the relative standard error (RSE) of the accuracy ranged from -12 to 14%. The developed MEPS/LC-MS/MS method allowed for simultaneous analysis of five antipsychotics (olanzapine, quetiapine, clozapine, haloperidol, and chlorpromazine) in combination with seven antidepressants (mirtazapine, paroxetine, citalopram, sertraline, imipramine, clomipramine, fluoxetine), two anticonvulsants (carbamazepine and lamotrigine), and two anxiolytics (diazepam and clonazepam) in plasma samples from schizophrenic patients, which should be valuable for TDM purposes.
|
3 |
Desenvolvimento de fases monolíticas de sílica híbrida para microextração em sorvente empacotado (MEPS) de fármacos em amostras de plasma e análise por cromatografia líquida acoplada a espectrometria de massas em tandem (LC-MS/MS) / Synthesis of hybrid silica monoliths for microextraction by packed sorbent (MEPS) to determine drugs from plasma samples by liquid chromatography-tandem mass (LC-MS/MS)Israel Donizéti de Souza 27 July 2015 (has links)
Segundo a Organização Mundial da Saúde (OMS), a esquizofrenia é reconhecida como um transtorno neuropsiquiátrico grave que afeta mais de 21 milhões de pessoas em todo o mundo. Para diminuir os sintomas associados a esta doença, a maioria dos pacientes esquizofrênicos fazem uso concomitantemente de antipsicóticos, antidepressivos, ansiolíticos e anticonvulsivantes. O desenvolvimento de métodos analíticos para a determinação desses fármacos em fluidos biológicos é importante para ajustar as doses administradas, minimizar os efeitos adversos e verificar a anuência do paciente à terapia. A química analítica moderna tem se direcionado para a simplificação, através da miniaturização dos sistemas analíticos. Neste contexto, pode-se destacar a técnica de microextração em sorvente empacotado (MEPS). O desenvolvimento de novas fases extratoras para MEPS, como, os monolitos de sílica híbrida permitem pré-concentração seletiva dos analitos. Neste projeto monolitos de sílica híbrida funcionalizados com grupos aminopropil ou cianopropil foram sintetizados pelo processo sol-gel. Estes monolitos apresentaram estrutura contínua, uniforme e porosa, como evidenciado pelas imagens de microscopia eletrônica de varredura (MEV). As análises de espectroscopia vibracional na região do infravermelho por transformada de Fourier (FTIR) dos monolitos de sílica híbrida exibiram picos facilmente identificáveis, característicos dos grupos cianopropil e aminopropil. Estes monolitos foram avaliados como fase estacionária para a MEPS para a determinação de fármacos em amostras de plasma por cromatografia líquida acoplada a espectrometria de massa em Tandem (LC-MS/MS). As variáveis MEPS (influência do pH na sorção dos analitos, número de ciclos aspirar/dispensar, etapa de limpeza do sorvente e solvente de eluição) foram otimizadas para aumentar a eficiência da extração. Em comparação com a fase de sílica híbrida aminopropil, a fase de sílica híbrida cianopropil apresentou maior capacidade de sorção para os fármacos em estudo. O método desenvolvido, MEPS/LC-MS/MS, empregando a fase extratora de sílica híbrida cianopropil, apresentou linearidade adequada com concentrações que variaram desde o limite inferior de quantificação (0,05-1,00 ng.mL-1) até o limite superior de quantificação (40-10.500 ng.mL-1) com coeficientes de determinação (R2) maiores do que 0,9955. Este método apresentou precisão com coeficientes de variação (CV) inferiores a 14% e exatidão com erro padrão relativo (EPR) de -12 a 14%. O método MEPS/LC-MS/MS foi aplicado com êxito para análise simultânea de cinco antipsicóticos (olanzapina, quetiapina, clozapina, haloperidol e clorpromazina), em combinação com sete antidepressivos (mirtazapina, paroxetina, citalopram, sertralina, imipramina, clomipramina e fluoxetina), dois anticonvulsivantes (carbamazepina e lamotrigina) e dois ansiolíticos (diazepam e clonazepam) em amostras de plasma de pacientes esquizofrênicos para fins de monitorização terapêutica. / According to World Health Organization (WHO), schizophrenia is recognizably a devastating neuropsychiatric disorder that affects more than 21 million people worldwide. To lessen the symptoms associated with the disease, most schizophrenic patients use other classes of drugs such as antidepressants, anxiolytics, and anticonvulsants concomitantly with antipsychotics. Developing analytical methods to quantify these drugs in biological fluids is important in therapeutic drug monitoring (TDM) to adjust doses, minimize adverse effects, and check patient adherence to the therapy. Regarding miniaturization and automation, microextraction by packed sorbent (MEPS) is a promising sample preparation technique. Sample preparation of biological matrixes is an important step in analytical processes: it removes endogenous components from the sample and pre-concentrates trace-level analytes. The development of new phases for MEPS such as the hybrid silica monoliths allows selective pre-concentration of the analytes. The present study reports on the synthesis of two hybrid silica monoliths functionalized with aminopropyl or cyanopropyl groups by the solgel process; evaluates these monoliths as selective stationary phase for MEPS to determine drugs in plasma samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS); and discusses important factors (influence of pH on the sorption of analytes, number of draw/eject cycles, washing step, and elution solvent) related to the optimization of MEPS efficiency. The prepared hybrid silica monoliths consisted of a uniform, porous, and continuous silica monolithic network, as shown by scanning electron microscopy (MEV) images. The Fourier-transform infrared spectroscopy (FTIR) spectra of the hybrid silica monoliths displayed readily identifiable peaks, characteristic of the cyanopropyl and aminopropyl groups. Compared with the aminopropyl hybrid silica phase, the cyanopropyl hybrid silica phase exhibited higher binding capacity for most of the target drugs. The developed method, MEPS/LC-MS/MS, afforded adequate linearity at concentrations ranging from the lower limit of quantification (0.05 to 1.00 ng.mL-1) to the upper limit of quantification (40 to 10500 ng.mL-1); the coefficients of determination (R2) were higher than 0.9955. The precision of the method presented coefficients of variation (CV) lower than 14%; the relative standard error (RSE) of the accuracy ranged from -12 to 14%. The developed MEPS/LC-MS/MS method allowed for simultaneous analysis of five antipsychotics (olanzapine, quetiapine, clozapine, haloperidol, and chlorpromazine) in combination with seven antidepressants (mirtazapine, paroxetine, citalopram, sertraline, imipramine, clomipramine, fluoxetine), two anticonvulsants (carbamazepine and lamotrigine), and two anxiolytics (diazepam and clonazepam) in plasma samples from schizophrenic patients, which should be valuable for TDM purposes.
|
4 |
Desenvolvimento das barras imunosorventes de agitação e avaliação das técnicas extração sortiva em barra de agitação, microextração em sorvente empacotado e cromatografia líquida para análise de antidepressivos em amostras de plasma / Development of immunosorbent stir bars and evaluation of stir bar sorptive extraction, microextraction by packed sorbent and liquid chromatography for the analysis of antidepressants in plasma samplesLeandro, Fernanda Zampieri 15 December 2010 (has links)
Neste trabalho, os anticorpos policlonais e monoclonais anti-fluoxetina foram produzidos em coelhos e camundongos, respectivamente, por imunização com o conjugado fluoxetina-soroalbumina bovina. Os anticorpos obtidos foram caracterizados em função da especificidade contra o fármaco por ELISA (enzyme linked immunosorbent assay) e posteriormente, purificados por afinidade em coluna fluoxetina-agarose labmade. Os anticorpos purificados foram imobilizados covalentemente na superfície vítrea das barras SBSE (extração sortiva em barra de agitação) labmade. Após a derivatização das barras com 3-aminopropiltrietoxisilano, dois métodos distintos de acoplamento dos anticorpos às barras SBSE foram avaliados: ativação com glutaraldeído e succinilação seguida de ativação via éster N-hidroxisuccinimida (NHS). A funcionalização das barras SBSE foi comprovada através da imobilização de enzima peroxidase (HRP) em lugar do anticorpo e posterior ensaio enzimático com as barras. Várias barras SBSE com diferentes áreas (1,2; 2,4; e 4,0 cm2) foram preparadas, dentre as quais, as com maior área imunosorvente apresentaram maiores taxas de recuperação do fármaco. A avaliação da morfologia da superfície da barra SBSE imunosorvente foi realizada através de Microscopia Eletrônica de Varredura (MEV). As variáveis do processo SBSE de imunoafinidade foram otimizadas para estabelecer o equilíbrio de sorção antígeno-anticorpo em um menor tempo de análise e obtenção de limite de quantificação compatível com o intervalo terapêutico do fármaco. As capacidades adsortivas das barras imunosorventes foram de 1,2 e 8 microgramas por cm2 para anticorpos policlonais e monoclonais, respectivamente. Os imunosorventes desenvolvidos apresentaram reatividade-cruzada apenas com norfluoxetina (metabólito ativo de fluoxetina). As barras imunosorventes foram reutilizadas aproximadamente 30 vezes, sem perda significativa da eficiência das extrações. Baseados nos parâmetros de validação analítica avaliados, os métodos de SBSE/LC-FD de imunoafinidade desenvolvidos são adequados para a determinação de fluoxetina em amostras de plasma de pacientes em terapia com o fármaco, para fins de monitorização terapêutica. Por conseguinte, esses métodos foram aplicados com êxito para análises de amostras de plasma de pacientes idosos em terapia com Prozac®. Neste trabalho, o método MEPS (microextração em sorvente empacotado)/LC-UV também foi desenvolvido e validado para análise simultânea de sertralina, paroxetina, citalopram, fluoxetina e mirtazapina em amostras de plasma para fins de monitorização terapêutica. As variáveis do processo MEPS foram otimizadas (pH e volume da amostra, força iônica, volume dos ciclos aspirar-dispensar e condições de dessorção) para estabelecer o equilíbrio de sorção em menor tempo de análise e obter sensibilidade analítica adequada para a determinação dos antidepressivos no intervalo terapêutico. O método MEPS/LC-UV desenvolvido permitiu integração da dessorção dos analitos e injeção da amostra no sistema cromatográfico (LC-UV) em uma única etapa, usando a microsseringa de extração MEPS. A fase extratora MEPS, M1 (C8/SCX), foi reutilizada mais de 50 vezes com perda mínima da eficiência da extração, comprovando a robustez do material sorvente. Segundo os parâmetros de validação analítica avaliados, o método MEPS/LC-UV desenvolvido é adequado para a determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica. / In this work, polyclonal and monoclonal anti-fluoxetine antibodies were developed in rabbits and mice by immunization with fluoxetine-bovine albumin conjugate, respectively. The developed antibodies were characterized on the basis of the specificity against the drug by ELISA (enzyme linked immunosorbent assay) and, subsequently they were purified by labmade fluoxetine-agarose affinity column. The purified antibodies were covalently immobilized onto the glass surface of labmade SBSE (stir bar sorptive extraction) bars. After derivatization of the bars with 3-aminopropyltriethoxysilane, two distinct methods were evaluated for the antibodies coupling to the SBSE bars: activation with glutaraldehyde and succinylation activation via ester N-hydroxysuccinimide (NHS). The functionalization of SBSE bars was confirmed by the immobilization of peroxidase (HRP) instead of the antibody and, subsequent enzymatic assay with the bars. Several SBSE bars with different areas (1.2, 2.4, and 4.0 cm2) were prepared, among of them the largest immunosorbent area showed higher recovery rates of the drug. The evaluation of surface morphology of the SBSE immunosorbent bar was performed using scanning electron microscopy (SEM). The SBSE immunoaffinity variables were optimized to establish sorption equilibrium of antigen-antibody in a short time analysis and to obtain the limit of quantification compatible with the therapeutic range of the drug. The adsorptive capacities of the immunosorbent bars were 1.2 and 8 micrograms per cm2 for polyclonal and monoclonal antibodies, respectively. The developed immunosorbents showed cross-reactivity only with norfluoxetine (active metabolite of fluoxetine). The immunosorbent bars were reused approximately 30 times without significant loss of the extraction efficiency. Based on evaluated analytical validation parameters, the developed immunoaffinity SBSE/LC-FD methods are suitable for the determination of fluoxetine in plasma samples from patients on therapy with the antidepressant for therapeutic drug monitoring. Therefore, these methods were successfully applied for the analysis of plasma samples from elderly patients undergoing therapy with Prozac®. In this work, the method MEPS (microextraction by packed sorbent)/ LC-UV was also developed and validated for the simultaneous analysis of sertraline, paroxetine, citalopram, fluoxetine and mirtazapine in plasma samples for therapeutic drug monitoring. The MEPS process variables were optimized (pH, sample volume, ionic strength, draw-eject cycles volume and desorption conditions) to establish the sorption equilibrium in a short time analysis and to obtain adequate analytical sensitivity for determination of antidepressants within therapeutic range. The developed MEPS/LC-UV method allowed integration of the analytes desorption and sample injection in the chromatographic system (LC-UV) in a single step, using a MEPS extraction microsyringe. The MEPS extraction phase, M1 (C8/SCX) was reused over 50 times with minimum loss of extraction efficiency, proving the robustness of the sorbent material. According to the evaluated analytical validation parameters, the developed MEPS/LC-UV method is suitable for the determination of antidepressants in plasma samples for therapeutic drug monitoring.
|
5 |
Microextração de canabinoides em urina usando dispositivo empacotado com polímero molecularmente impresso e análise por cromatografia líquida - espectrometria de massas sequencial / Microextraction of cannabinoids in urine using device packed with molecularly imprinted polymer and analysis by liquid chromatography - sequential mass spectrometrySartore, Douglas Morisue 30 July 2018 (has links)
O preparo da amostra é uma das etapas mais importantes em toda a análise química. O isolamento e a concentração dos componentes da amostra são cruciais e busca-se sempre que essas etapas sejam as mais simples e consumam o mínimo possível de tempo e reagentes. Nos últimos anos, um tipo de material tem se mostrado bastante útil para análises químicas a partir de fluidos biológicos, os polímeros molecularmente impressos (MIPs). Os MIPs são sintetizados por reações de polimerização, na presença de uma molécula molde (template). A molécula molde se liga aos monômeros funcionais do polímero durante a reação de polimerização e permanece ligada à superfície das cadeias poliméricas quando a reação se completa. Terminada a polimerização, realiza-se a completa lavagem das moléculas molde, assim, restam na superfície polimérica cavidades tridimensionais complementares à molécula empregada como molde. Essas cavidades permitem a ligação reversível e preferencial da molécula molde ou outras com estrutura química semelhante. A Cannabis sativa é a droga ilícita mais consumida em todo o mundo e nos últimos anos muita atenção tem se voltado a seus efeitos toxicológicos no corpo humano e a aplicações medicinais. Nesta dissertação, foi sintetizado um MIP com a molécula molde catequina para a extração e posterior análise por LC-MS/MS dos canabinóides Δ9-tetrahidrocanabinol (THC), 11-hidroxi-Δ9-tetrahidrocannabinol (THC-OH) e 11-nor-Δ9-tetrahidrocannabinol-9-ácido carboxílico (THC-COOH) em amostras de urina. O MIP produzido foi empacotado em microdispositivo e empregado no preparo das amostras de urina por microextração por sorvente empacotado (MEPS). O método desenvolvido apresentou boa linearidade (valores de r de 0,977 para o THC e 0,994 para THC-OH e THC-COOH). Os limites de detecção e de quantificação foram respectivamente de 5 ng mL-1 e 20 ng mL-1, para os compostos THC e THC-OH, na faixa linear de 25 a 250 ng mL-1. Para o composto THC-COOH os limites de detecção e quantificação alcançados foram de 1 ng mL-1 e 5 ng mL-1, respectivamente, na faixa linear de 5 a 170 ng mL-1. O método apresentou valores razoáveis de precisão entre 3,2% (THC-COOH) e 25,1% (THC) e de exatidão, que variou entre -18,4 e 17,4 (ambos para o THC). O MIP empregado no preparo da amostra mostrou-se mais seletivo e específico do que materiais normalmente empregados para a extração dos canabinoides das amostras de urina, além de a técnica de extração por MEPS apresentar baixo consumo de solventes e amostra para a extração dos analitos e posterior análise por LC-MS/MS. / The sample preparation is one of the most important steps in every chemical analysis. The isolation and concentration of the sample components are crucial and it is always sought that these steps are simple and consume the lowest amount of time and reagents. In the recent years, a type of material has proved to be very useful for chemical analyzes of biological fluids, the molecularly imprinted polymers (MIPs). MIPs are synthesized by polymerization reactions in the presence of a template molecule. The template molecule binds to the functional monomers of the polymer during the polymerization reaction and remains bonded to the surface of the polymeric chains after the reaction is complete. After the polymerization is finished, the complete washing of the template molecules is carried out, thus, three-dimensional cavities, complementary to the molecule used as a template, remain on the polymer surface. These cavities allow the reversible and preferential bonding of the template molecule or others with similar chemical structure. Cannabis sativa is the most commonly consumed illicit drug in the world and in recent years much attention has focused on its toxicological effects on human body and for medical applications. In this master dissertation, a MIP was synthesized with the catechin molecule as template, for extraction and subsequent analysis by LC-MS/MS of the cannabinoids Δ9-tetrahydrocannabinol (THC), 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH), and 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in urine samples. The MIP produced was packed in a microdevice and used in the preparation of the urine samples by microextraction by packed sorbent (MEPS). The developed method showed good linearity (r values of 0.977 for THC and 0.994 for THC-OH and THC-COOH). The detection and quantification limits were respectively 5 ng mL-1 and 20 ng mL-1 for THC and THC-OH in the linear range from 25 to 250 ng mL-1. For the compound THC-COOH the limits of detection and quantification achieved were 1 ng mL-1 and 5 ng mL-1, respectively, in the linear range from 5 to 170 ng mL-1. The method presented reasonable values of precision, between 3.2% (for THC-COOH) and 25.1% (for THC) and displayed accuracy ranging from -18.4 to 17.4 (both for THC). The MIP used in the sample preparation was more selective and specific than other materials usually employed for the extraction of the cannabinoids from the urine samples. The MEPS technique also showed low consumption of solvents and sample for sample preparation, extraction of analytes and subsequent analysis by LC-MS/MS.
|
6 |
Síntese de novos materiais à base de grafeno para aplicação em microextração por sorvente empacotado MEPS na extração de tetraciclinas presentes no leite com posterior análise por cromatografia líquida acoplada a espectrometria de massas sequencial <i / MEPS-HPLC-MS/MS determination of tetracyclines in milk sample utilizing graphene-particles supported on sílica as sorbent phaseMaciel, Edvaldo Vasconcelos Soares 27 July 2017 (has links)
O crescimento da população mundial e a expansão industrial são fatores que atualmente desencadeiam um aumento no consumo de produtos e geração de resíduos. Frequentemente utilizados na medicina tradicional e veterinária, os antibióticos são classificados como uma classe emergente de poluentes, pois, devido à sua baixa taxa de degradação e à ineficácia dos sistemas de tratamentos de água, encontram-se disseminados no meio ambiente e nos alimentos. Em consequência desse fato, estudos para o desenvolvimento de novos materiais e métodos que removam estes contaminantes utilizando menor quantidade de consumíveis químicos e a baixo custo, têm sido um campo em desenvolvimento na química analítica. Inserido nesse contexto encontra-se o grafeno, que devido à sua estrutura de anéis aromáticos com elétrons π deslocalizados e elevada área superficial (3600 m2/g), pode favorecer fenômenos de sorção, elevando a eficiência na extração de contaminantes presentes em matrizes complexas. O objetivo do projeto foi sintetizar e caracterizar novas fases sorventes à base de grafeno para atuar no preparo da amostra avaliando a eficácia destas na remoção de tetraciclinas presentes em leite. Para isso, utilizou-se da microextração por sorvente empacotado MEPS como método de preparo de amostra com posterior análise por cromatografia líquida acoplada a espectrometria de massas HPLC-MS/MS. A caracterização dos materiais foi feita através de microscopia eletrônica de varredura MEV e espectroscopia vibracional na região do infravermelho IV revelando eficácia na síntese das folhas de óxido de grafeno, assim como, no recobrimento das partículas de sílica com os novos materiais. Foram avaliadas as fases extratoras: G, GO-SIL, G-Sil e C18-G-Sil com relação a eficiência na extração das tetraciclinas. A fase G-Sil mostrou-se a mais apropriada para continuidade do estudo, pois apresentou os melhores resultados. Com o objetivo de otimizar a etapa de preparo de amostra, foi feito um planejamento fatorial fracionário 24-1 avaliando as variáveis químicas: solvente de eluição, força iônica, pH da solução de lavagem e inclusão de EDTA na solução tampão de Mcllvaine (pH 4.2). Posteriormente foi feito um planejamento fatorial completo 23 visando a otimização dos ciclos de extração da MEPS, possibilitando determinar a condição ótima de extração do método. Baseando-se no documento: ICH - Q2 (R1) guideline, a metodologia foi submetida a testes para avaliar as figuras de mérito referentes a validação analítica. O método apresentou faixa linear de 15 - 110 µg/L, LQ entre 0,05 e 0,9 µg/L e boa seletividade. A precisão foi avaliada intra e inter-dia apresentando desvio padrão relativo - RSD abaixo de 18%. Ao final do desenvolvimento do estudo foram analisadas onze amostras reais incluindo leite bovino, caprino, ovino e leite em pó. A aplicação em amostras de diferentes espécies reforça a versatilidade do método desenvolvido, além de evidenciar o elevado potencial dos novos materiais de grafeno para atuar como sorvente no preparo da amostra. / Nowadays, the rise of world population and industrial expansion are leading to an increase in consumption and consequently waste generation. Large quantities of chemical residues are released into the environment affecting humans and wildlife. Among these residues, antibiotics used in medicine and veterinary are classified as an emerging contaminant due to their low degradation rate, ineffectiveness of wastewater treatment and consequently water and food contamination. An effort has been made to develop microextraction techniques to remove these drugs using reduce volume of solvent and chemical consumable and researches of new sorbent phases are increasing due the high potential to improve these microextraction techniques. Recent studies pinpoint graphene (G) as an effectively sorbent phase to act in sample preparation. G has a structure composed by carbon nanosheets arranged in a honeycomb pattern with large surface area (3600 m2 /g) and delocalized π-electrons system that suggests good interaction between them and contaminants compounds such as veterinary drugs, pesticides, personal care products etc. This study focuses to evaluate sorbent phases based upon graphene particle supported on silica to analyze Tetracycline residues present in milk. For this purpose, was used microextraction by packed sorbent - MEPS as sample preparation method with analysis by liquid chromatography and mass spectrometry. The characterization of synthesized materials was performed by scanning electron microscopy - SEM and vibrational spectroscopy in infrared region - FTIR. The results suggest that synthesis of graphene\'s particles as well as the coating of silica surface with these materials were both performed. To evaluate extraction efficiency each sorbent material: GO-Sil, G-Sil, G, C18-GO-Sil were tested in MEPS and confronted to commercial phases: C8 and C18. By the results, G-Sil was choose to application as sorbent phase. MEPS extractions were optimized and the effect of some factors was investigated by application of experimental design. Firstly, a factorial experimental design 2(4-1) was executed to evaluate chemistry variables such as elution solvent, washing solution, media ionic strength and inclusion of EDTA salt in Mcllvaine solution. After, an experimental design 23 was made in order to estimate the cycles of MEPS extraction like sampling, washing and elution steps. By the results, an optimized extraction conditional was achieved and evaluation of validation parameters was carried out on sequence based on the ICH - Q2 (R1) guide. The method showed linearity ranging from 15 - 110 µg/L, LOQ values from 0,05 to 0,9 µg/L and good selectivity. Precision showed relative standard deviation RSD less than 18% to intra and inter-day analysis. The developed method was applied in analysis of eleven milk samples including bovine, caprine and ovine milk and milk powder. Application in samples from different species enhances the versatility of this analytical method and show the great potential for graphene\'s particles to act as sorbent phase in sample preparation.
|
7 |
Síntese de novos materiais à base de grafeno para aplicação em microextração por sorvente empacotado MEPS na extração de tetraciclinas presentes no leite com posterior análise por cromatografia líquida acoplada a espectrometria de massas sequencial <i / MEPS-HPLC-MS/MS determination of tetracyclines in milk sample utilizing graphene-particles supported on sílica as sorbent phaseEdvaldo Vasconcelos Soares Maciel 27 July 2017 (has links)
O crescimento da população mundial e a expansão industrial são fatores que atualmente desencadeiam um aumento no consumo de produtos e geração de resíduos. Frequentemente utilizados na medicina tradicional e veterinária, os antibióticos são classificados como uma classe emergente de poluentes, pois, devido à sua baixa taxa de degradação e à ineficácia dos sistemas de tratamentos de água, encontram-se disseminados no meio ambiente e nos alimentos. Em consequência desse fato, estudos para o desenvolvimento de novos materiais e métodos que removam estes contaminantes utilizando menor quantidade de consumíveis químicos e a baixo custo, têm sido um campo em desenvolvimento na química analítica. Inserido nesse contexto encontra-se o grafeno, que devido à sua estrutura de anéis aromáticos com elétrons π deslocalizados e elevada área superficial (3600 m2/g), pode favorecer fenômenos de sorção, elevando a eficiência na extração de contaminantes presentes em matrizes complexas. O objetivo do projeto foi sintetizar e caracterizar novas fases sorventes à base de grafeno para atuar no preparo da amostra avaliando a eficácia destas na remoção de tetraciclinas presentes em leite. Para isso, utilizou-se da microextração por sorvente empacotado MEPS como método de preparo de amostra com posterior análise por cromatografia líquida acoplada a espectrometria de massas HPLC-MS/MS. A caracterização dos materiais foi feita através de microscopia eletrônica de varredura MEV e espectroscopia vibracional na região do infravermelho IV revelando eficácia na síntese das folhas de óxido de grafeno, assim como, no recobrimento das partículas de sílica com os novos materiais. Foram avaliadas as fases extratoras: G, GO-SIL, G-Sil e C18-G-Sil com relação a eficiência na extração das tetraciclinas. A fase G-Sil mostrou-se a mais apropriada para continuidade do estudo, pois apresentou os melhores resultados. Com o objetivo de otimizar a etapa de preparo de amostra, foi feito um planejamento fatorial fracionário 24-1 avaliando as variáveis químicas: solvente de eluição, força iônica, pH da solução de lavagem e inclusão de EDTA na solução tampão de Mcllvaine (pH 4.2). Posteriormente foi feito um planejamento fatorial completo 23 visando a otimização dos ciclos de extração da MEPS, possibilitando determinar a condição ótima de extração do método. Baseando-se no documento: ICH - Q2 (R1) guideline, a metodologia foi submetida a testes para avaliar as figuras de mérito referentes a validação analítica. O método apresentou faixa linear de 15 - 110 µg/L, LQ entre 0,05 e 0,9 µg/L e boa seletividade. A precisão foi avaliada intra e inter-dia apresentando desvio padrão relativo - RSD abaixo de 18%. Ao final do desenvolvimento do estudo foram analisadas onze amostras reais incluindo leite bovino, caprino, ovino e leite em pó. A aplicação em amostras de diferentes espécies reforça a versatilidade do método desenvolvido, além de evidenciar o elevado potencial dos novos materiais de grafeno para atuar como sorvente no preparo da amostra. / Nowadays, the rise of world population and industrial expansion are leading to an increase in consumption and consequently waste generation. Large quantities of chemical residues are released into the environment affecting humans and wildlife. Among these residues, antibiotics used in medicine and veterinary are classified as an emerging contaminant due to their low degradation rate, ineffectiveness of wastewater treatment and consequently water and food contamination. An effort has been made to develop microextraction techniques to remove these drugs using reduce volume of solvent and chemical consumable and researches of new sorbent phases are increasing due the high potential to improve these microextraction techniques. Recent studies pinpoint graphene (G) as an effectively sorbent phase to act in sample preparation. G has a structure composed by carbon nanosheets arranged in a honeycomb pattern with large surface area (3600 m2 /g) and delocalized π-electrons system that suggests good interaction between them and contaminants compounds such as veterinary drugs, pesticides, personal care products etc. This study focuses to evaluate sorbent phases based upon graphene particle supported on silica to analyze Tetracycline residues present in milk. For this purpose, was used microextraction by packed sorbent - MEPS as sample preparation method with analysis by liquid chromatography and mass spectrometry. The characterization of synthesized materials was performed by scanning electron microscopy - SEM and vibrational spectroscopy in infrared region - FTIR. The results suggest that synthesis of graphene\'s particles as well as the coating of silica surface with these materials were both performed. To evaluate extraction efficiency each sorbent material: GO-Sil, G-Sil, G, C18-GO-Sil were tested in MEPS and confronted to commercial phases: C8 and C18. By the results, G-Sil was choose to application as sorbent phase. MEPS extractions were optimized and the effect of some factors was investigated by application of experimental design. Firstly, a factorial experimental design 2(4-1) was executed to evaluate chemistry variables such as elution solvent, washing solution, media ionic strength and inclusion of EDTA salt in Mcllvaine solution. After, an experimental design 23 was made in order to estimate the cycles of MEPS extraction like sampling, washing and elution steps. By the results, an optimized extraction conditional was achieved and evaluation of validation parameters was carried out on sequence based on the ICH - Q2 (R1) guide. The method showed linearity ranging from 15 - 110 µg/L, LOQ values from 0,05 to 0,9 µg/L and good selectivity. Precision showed relative standard deviation RSD less than 18% to intra and inter-day analysis. The developed method was applied in analysis of eleven milk samples including bovine, caprine and ovine milk and milk powder. Application in samples from different species enhances the versatility of this analytical method and show the great potential for graphene\'s particles to act as sorbent phase in sample preparation.
|
8 |
Microextração de canabinoides em urina usando dispositivo empacotado com polímero molecularmente impresso e análise por cromatografia líquida - espectrometria de massas sequencial / Microextraction of cannabinoids in urine using device packed with molecularly imprinted polymer and analysis by liquid chromatography - sequential mass spectrometryDouglas Morisue Sartore 30 July 2018 (has links)
O preparo da amostra é uma das etapas mais importantes em toda a análise química. O isolamento e a concentração dos componentes da amostra são cruciais e busca-se sempre que essas etapas sejam as mais simples e consumam o mínimo possível de tempo e reagentes. Nos últimos anos, um tipo de material tem se mostrado bastante útil para análises químicas a partir de fluidos biológicos, os polímeros molecularmente impressos (MIPs). Os MIPs são sintetizados por reações de polimerização, na presença de uma molécula molde (template). A molécula molde se liga aos monômeros funcionais do polímero durante a reação de polimerização e permanece ligada à superfície das cadeias poliméricas quando a reação se completa. Terminada a polimerização, realiza-se a completa lavagem das moléculas molde, assim, restam na superfície polimérica cavidades tridimensionais complementares à molécula empregada como molde. Essas cavidades permitem a ligação reversível e preferencial da molécula molde ou outras com estrutura química semelhante. A Cannabis sativa é a droga ilícita mais consumida em todo o mundo e nos últimos anos muita atenção tem se voltado a seus efeitos toxicológicos no corpo humano e a aplicações medicinais. Nesta dissertação, foi sintetizado um MIP com a molécula molde catequina para a extração e posterior análise por LC-MS/MS dos canabinóides Δ9-tetrahidrocanabinol (THC), 11-hidroxi-Δ9-tetrahidrocannabinol (THC-OH) e 11-nor-Δ9-tetrahidrocannabinol-9-ácido carboxílico (THC-COOH) em amostras de urina. O MIP produzido foi empacotado em microdispositivo e empregado no preparo das amostras de urina por microextração por sorvente empacotado (MEPS). O método desenvolvido apresentou boa linearidade (valores de r de 0,977 para o THC e 0,994 para THC-OH e THC-COOH). Os limites de detecção e de quantificação foram respectivamente de 5 ng mL-1 e 20 ng mL-1, para os compostos THC e THC-OH, na faixa linear de 25 a 250 ng mL-1. Para o composto THC-COOH os limites de detecção e quantificação alcançados foram de 1 ng mL-1 e 5 ng mL-1, respectivamente, na faixa linear de 5 a 170 ng mL-1. O método apresentou valores razoáveis de precisão entre 3,2% (THC-COOH) e 25,1% (THC) e de exatidão, que variou entre -18,4 e 17,4 (ambos para o THC). O MIP empregado no preparo da amostra mostrou-se mais seletivo e específico do que materiais normalmente empregados para a extração dos canabinoides das amostras de urina, além de a técnica de extração por MEPS apresentar baixo consumo de solventes e amostra para a extração dos analitos e posterior análise por LC-MS/MS. / The sample preparation is one of the most important steps in every chemical analysis. The isolation and concentration of the sample components are crucial and it is always sought that these steps are simple and consume the lowest amount of time and reagents. In the recent years, a type of material has proved to be very useful for chemical analyzes of biological fluids, the molecularly imprinted polymers (MIPs). MIPs are synthesized by polymerization reactions in the presence of a template molecule. The template molecule binds to the functional monomers of the polymer during the polymerization reaction and remains bonded to the surface of the polymeric chains after the reaction is complete. After the polymerization is finished, the complete washing of the template molecules is carried out, thus, three-dimensional cavities, complementary to the molecule used as a template, remain on the polymer surface. These cavities allow the reversible and preferential bonding of the template molecule or others with similar chemical structure. Cannabis sativa is the most commonly consumed illicit drug in the world and in recent years much attention has focused on its toxicological effects on human body and for medical applications. In this master dissertation, a MIP was synthesized with the catechin molecule as template, for extraction and subsequent analysis by LC-MS/MS of the cannabinoids Δ9-tetrahydrocannabinol (THC), 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH), and 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in urine samples. The MIP produced was packed in a microdevice and used in the preparation of the urine samples by microextraction by packed sorbent (MEPS). The developed method showed good linearity (r values of 0.977 for THC and 0.994 for THC-OH and THC-COOH). The detection and quantification limits were respectively 5 ng mL-1 and 20 ng mL-1 for THC and THC-OH in the linear range from 25 to 250 ng mL-1. For the compound THC-COOH the limits of detection and quantification achieved were 1 ng mL-1 and 5 ng mL-1, respectively, in the linear range from 5 to 170 ng mL-1. The method presented reasonable values of precision, between 3.2% (for THC-COOH) and 25.1% (for THC) and displayed accuracy ranging from -18.4 to 17.4 (both for THC). The MIP used in the sample preparation was more selective and specific than other materials usually employed for the extraction of the cannabinoids from the urine samples. The MEPS technique also showed low consumption of solvents and sample for sample preparation, extraction of analytes and subsequent analysis by LC-MS/MS.
|
9 |
Desenvolvimento das barras imunosorventes de agitação e avaliação das técnicas extração sortiva em barra de agitação, microextração em sorvente empacotado e cromatografia líquida para análise de antidepressivos em amostras de plasma / Development of immunosorbent stir bars and evaluation of stir bar sorptive extraction, microextraction by packed sorbent and liquid chromatography for the analysis of antidepressants in plasma samplesFernanda Zampieri Leandro 15 December 2010 (has links)
Neste trabalho, os anticorpos policlonais e monoclonais anti-fluoxetina foram produzidos em coelhos e camundongos, respectivamente, por imunização com o conjugado fluoxetina-soroalbumina bovina. Os anticorpos obtidos foram caracterizados em função da especificidade contra o fármaco por ELISA (enzyme linked immunosorbent assay) e posteriormente, purificados por afinidade em coluna fluoxetina-agarose labmade. Os anticorpos purificados foram imobilizados covalentemente na superfície vítrea das barras SBSE (extração sortiva em barra de agitação) labmade. Após a derivatização das barras com 3-aminopropiltrietoxisilano, dois métodos distintos de acoplamento dos anticorpos às barras SBSE foram avaliados: ativação com glutaraldeído e succinilação seguida de ativação via éster N-hidroxisuccinimida (NHS). A funcionalização das barras SBSE foi comprovada através da imobilização de enzima peroxidase (HRP) em lugar do anticorpo e posterior ensaio enzimático com as barras. Várias barras SBSE com diferentes áreas (1,2; 2,4; e 4,0 cm2) foram preparadas, dentre as quais, as com maior área imunosorvente apresentaram maiores taxas de recuperação do fármaco. A avaliação da morfologia da superfície da barra SBSE imunosorvente foi realizada através de Microscopia Eletrônica de Varredura (MEV). As variáveis do processo SBSE de imunoafinidade foram otimizadas para estabelecer o equilíbrio de sorção antígeno-anticorpo em um menor tempo de análise e obtenção de limite de quantificação compatível com o intervalo terapêutico do fármaco. As capacidades adsortivas das barras imunosorventes foram de 1,2 e 8 microgramas por cm2 para anticorpos policlonais e monoclonais, respectivamente. Os imunosorventes desenvolvidos apresentaram reatividade-cruzada apenas com norfluoxetina (metabólito ativo de fluoxetina). As barras imunosorventes foram reutilizadas aproximadamente 30 vezes, sem perda significativa da eficiência das extrações. Baseados nos parâmetros de validação analítica avaliados, os métodos de SBSE/LC-FD de imunoafinidade desenvolvidos são adequados para a determinação de fluoxetina em amostras de plasma de pacientes em terapia com o fármaco, para fins de monitorização terapêutica. Por conseguinte, esses métodos foram aplicados com êxito para análises de amostras de plasma de pacientes idosos em terapia com Prozac®. Neste trabalho, o método MEPS (microextração em sorvente empacotado)/LC-UV também foi desenvolvido e validado para análise simultânea de sertralina, paroxetina, citalopram, fluoxetina e mirtazapina em amostras de plasma para fins de monitorização terapêutica. As variáveis do processo MEPS foram otimizadas (pH e volume da amostra, força iônica, volume dos ciclos aspirar-dispensar e condições de dessorção) para estabelecer o equilíbrio de sorção em menor tempo de análise e obter sensibilidade analítica adequada para a determinação dos antidepressivos no intervalo terapêutico. O método MEPS/LC-UV desenvolvido permitiu integração da dessorção dos analitos e injeção da amostra no sistema cromatográfico (LC-UV) em uma única etapa, usando a microsseringa de extração MEPS. A fase extratora MEPS, M1 (C8/SCX), foi reutilizada mais de 50 vezes com perda mínima da eficiência da extração, comprovando a robustez do material sorvente. Segundo os parâmetros de validação analítica avaliados, o método MEPS/LC-UV desenvolvido é adequado para a determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica. / In this work, polyclonal and monoclonal anti-fluoxetine antibodies were developed in rabbits and mice by immunization with fluoxetine-bovine albumin conjugate, respectively. The developed antibodies were characterized on the basis of the specificity against the drug by ELISA (enzyme linked immunosorbent assay) and, subsequently they were purified by labmade fluoxetine-agarose affinity column. The purified antibodies were covalently immobilized onto the glass surface of labmade SBSE (stir bar sorptive extraction) bars. After derivatization of the bars with 3-aminopropyltriethoxysilane, two distinct methods were evaluated for the antibodies coupling to the SBSE bars: activation with glutaraldehyde and succinylation activation via ester N-hydroxysuccinimide (NHS). The functionalization of SBSE bars was confirmed by the immobilization of peroxidase (HRP) instead of the antibody and, subsequent enzymatic assay with the bars. Several SBSE bars with different areas (1.2, 2.4, and 4.0 cm2) were prepared, among of them the largest immunosorbent area showed higher recovery rates of the drug. The evaluation of surface morphology of the SBSE immunosorbent bar was performed using scanning electron microscopy (SEM). The SBSE immunoaffinity variables were optimized to establish sorption equilibrium of antigen-antibody in a short time analysis and to obtain the limit of quantification compatible with the therapeutic range of the drug. The adsorptive capacities of the immunosorbent bars were 1.2 and 8 micrograms per cm2 for polyclonal and monoclonal antibodies, respectively. The developed immunosorbents showed cross-reactivity only with norfluoxetine (active metabolite of fluoxetine). The immunosorbent bars were reused approximately 30 times without significant loss of the extraction efficiency. Based on evaluated analytical validation parameters, the developed immunoaffinity SBSE/LC-FD methods are suitable for the determination of fluoxetine in plasma samples from patients on therapy with the antidepressant for therapeutic drug monitoring. Therefore, these methods were successfully applied for the analysis of plasma samples from elderly patients undergoing therapy with Prozac®. In this work, the method MEPS (microextraction by packed sorbent)/ LC-UV was also developed and validated for the simultaneous analysis of sertraline, paroxetine, citalopram, fluoxetine and mirtazapine in plasma samples for therapeutic drug monitoring. The MEPS process variables were optimized (pH, sample volume, ionic strength, draw-eject cycles volume and desorption conditions) to establish the sorption equilibrium in a short time analysis and to obtain adequate analytical sensitivity for determination of antidepressants within therapeutic range. The developed MEPS/LC-UV method allowed integration of the analytes desorption and sample injection in the chromatographic system (LC-UV) in a single step, using a MEPS extraction microsyringe. The MEPS extraction phase, M1 (C8/SCX) was reused over 50 times with minimum loss of extraction efficiency, proving the robustness of the sorbent material. According to the evaluated analytical validation parameters, the developed MEPS/LC-UV method is suitable for the determination of antidepressants in plasma samples for therapeutic drug monitoring.
|
Page generated in 0.1452 seconds