• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 201
  • 11
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 217
  • 141
  • 103
  • 86
  • 82
  • 68
  • 55
  • 48
  • 41
  • 39
  • 37
  • 36
  • 31
  • 30
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Efeito da laserfototerapia na reparação de osso alveolar humano: análise microtomográfica e histomorfométrica / Effect of laserphototherapy on human alveolar bone repair: microtomographic and histomorphometrical analysis

Marcia Maria Altavista Romão 06 February 2015 (has links)
A instalação imediata de implante dental na região de molares é crítica, devido a grande perda óssea e da discrepância entre a espessura da crista alveolar e a plataforma do implante. Laserfototerapia (LFT) auxilia na reparação óssea, portanto pode acelerar a instalação do implante. Vinte pacientes foram selecionados para o estudo. Dez pacientes foram submetidos à LFT com laser de diodo de GaAlAs (808nm) no transcirúrgico de exodontia de molares, imediatamente após, e em 24h, 48h, 72h, 96h, 7 e 15 dias. As irradiações foram aplicadas no modo contínuo, em contato e pontual (100mW, 0,04cm2, 075,0J/cm2, 30s por ponto, 3J por ponto, em 5 pontos). O grupo controle (n=10) recebeu o mesmo tratamento, no entanto, o equipamento estava desligado. Quarenta dias depois, espécimes do tecido formado no interior dos alvéolos foram coletados para posterior análise por microtomografia (microCT) e histomorfometria. Dados de ambos os grupos foram comparados pelo test t de Student, enquanto aqueles das diferentes avaliações microtomográficas foram comparados pelo teste de correlação de Pearson (p<0.05). O volume relativo do osso, bem como a área relativa do osso foram significativamente maiores (p<0.001) no grupo laser do que no controle. No grupo controle houve correlação negativa significativa entre número e espessura de trabéculas, e entre número e separação entre trabéculas (p<0.01); entre espessura e separação das trabéculas a correlação foi positiva (p<0.01). O grupo laser mostrou correlação negativa significante entre número e espessura de trabéculas (p<0.01). A Laserfototerapia acelerou o reparo ósseo. Baseado na correlação de Pearson foi possível inferir que o grupo laser apresentou uma distribuição trabecular mais homogênea, com trabéculas menos espessas e mais numerosas, o que pode propiciar a redução do tempo para a instalação do implante. / The immediate dental implant placement in the molars region is critical, because of the high amount of bone loss and the discrepancy between the alveolar crest thickness and the dental implant platform. Laserphototherapy (LPT) improves bone repair thus could accelerate the implant placement. Twenty patients were selected for the study. Ten patients were submitted to LPT with GaAlAs diode laser (808nm) during molar extraction, immediately after, 24h, 48h, 72h, 96h, 7 and 15 days. The irradiations were applied in continuous wave, in contact and punctual mode (100mW, 0.04cm2, 075,0J/cm2, 30s per point, 3J per point, in 5 points). The control group (n=10) received the same treatment; however with the power of the laser off. Forty days later samples of the tissue formed inside the sockets were obtained for further microtomography (microCT) and histomorphometry analyses. Data of both groups were compared by the Student t test, whereas those from the different microCT parameters were compared by the Pearson correlation test (p<0.05). The relative bone volume, as well as the relative area were significantly higher (p<0.001) in the lased than the control group. In the control group there were negative correlations between number and thickness, and between number and separation of trabecula (p<0.01); between thickness and separation of trabecula the correlation was positive (p<0.01). The laser group showed significant negative correlation between the number and the thickness of trabecula (p<0.01). Laserphototherapy accelerated bone repair. By the Pearson correlation test it was possible to infer that the lased group presented a more homogeneous trabecula configuration, with thin and numerous trabecula, which would facilite the reduction of time for the installation of the implant.
132

Eficácia de remoção da medicação intracanal de hidróxido de cálcio com o uso do ultrassom associado ou não ao instrumento adicional, avaliada através da microtomografia computadorizada / Effectiveness of intracanal calcium hydroxide removal with the use of ultrasound with or without an additional instrument, evaluated by computed microtomography

Luciana Jorge Moraes Silva 02 September 2013 (has links)
Objetivos: avaliar a eficácia do uso da irrigação ultrassônica passiva (IUP), do instrumento adicional e da associação de ambos na remoção da medicação intracanal de hidróxido de cálcio através da microtomografia computadorizada (micro-CT). Material e métodos: foram selecionados 32 dentes humanos unirradiculares, preparados pela técnica de instrumentação rotatória com o sistema Protaper® universal até a lima final Finishing File 4 (F4). As amostras foram preenchidas com medicação intracanal de Ca(OH)2 associada ao propilenoglicol 400. Após 30 dias, os dentes foram divididos em quatro grupos, de acordo com a técnica de remoção da medicação. Nos grupos em que foi utilizada a IUP, esta foi realizada através da irrigação-aspiração com 5 mL de NaOCl 1%, 3 mL de EDTA 17% com agitação ultrassônica por um minuto a 2 mm do CRT e 5 mL de NaOCl 1%. O instrumento adicional utilizado foi a lima F5. No grupo controle, a remoção da medicação foi feita apenas com o instrumento final (F4) e com o uso do EDTA 17%, mantido por um minuto no interior do canal, sem ativação ultrassônica. As amostras foram avaliadas por meio da micro-CT, em três momentos distintos do procedimento endodôntico: 1) após preparo químico-cirúrgico do canal, 2) 30 dias após aplicação da medicação intracanal de Ca(OH)2 e 3) após remoção da medicação intracanal. As imagens microtomográficas foram avaliadas utilizando o software CTan (SkyScan). O canal foi dividido em terços apical, médio e cervical. Os conjuntos de dados foram analisados usando a escala de cinza do software CTan para quantificar o volume (em mm3) do canal após o preparo, o volume da medicação após 30 dias, o volume de resíduos de medicação e o volume do canal após remoção da medicação. A porcentagem de resíduos também foi calculada em relação ao volume do canal e ao volume de medicação após 30 dias. Finalmente, o aumento de volume do canal após a remoção também foi avaliada. Os dados foram analisados através de ANOVA de três fatores/teste de Tukey ou Kruskal-Wallis/Student-Newman-Keuls, com nível global de significância de 5%. Resultados: Independentemente da região do canal, o uso do ultrassom resultou em um menor volume de resíduos de MIC, em termos absolutos e em relação ao volume do canal. Em relação ao volume de medicação após 30 dias, o uso do ultrassom foi marginalmente significante. O uso do instrumento adicional não apresentou influência significante sobre a eficácia da remoção da MIC. A porcentagem de resíduos foi maior na região apical, quando o ultrassom não foi utilizado. Em números absolutos, a região cervical apresentou maior volume de resíduos. Em relação ao grupo controle, o uso do ultrassom resultou em um volume final maior do canal cirúrgico no terço cervical. Em termos percentuais, todas as técnicas resultaram em aumentos estatisticamente semelhantes do volume do canal cirúrgico para os terços cervical e médio. No terço apical, o grupo controle apresentou aumento percentual estatisticamente inferior aos demais. Conclusões: houve diferenças estatisticamente significantes na eficácia de remoção da MIC entre as técnicas testadas, sendo que o uso do ultrassom resultou em um menor volume de resíduos de MIC, em todos os grupos para um dado terço. / Objectives: To evaluate the efficacy of passive ultrasonic activation (PUI), an additional instrument and the combination of both for removal of intracanal calcium hydroxide using computerized microtomography (micro-CT). Methods: 32 singlerooted human teeth were prepared using the universal Protaper® rotary instrumentation system, with Finishing File 4 (F4) as the final file. The samples were filled with intracanal Ca(OH)2 plus propyleneglycol 400. After 30 days, the samples were divided into four groups according to the medication removal technique. In the groups where PUI was used, it was done by suction-irrigation with 5 mL of 1% NaOCl, 3 ml 17% EDTA with ultrasonic agitation for one minute at 2 mm from the working length and 5 ml of 1% NaOCl. The additional instrument used was the F5 file. In the control group, removal of the medication was performed only with the final instrument (F4) and using 17% EDTA, kept for one minute in the canal without ultrasonic activation. The samples were evaluated by micro-CT, at three different stages of the endodontic procedure: 1) after chemical-surgical preparation of canal 2) 30 days after application of the Ca(OH)2 medication 3) after removal of the medication. Microtomography images were evaluated using the CTan (SkyScan) Software. The root was divided in apical, middle and cervical. Each data set was analyzed using the CTan software gray scale to determine the volume (mm3) of the canal after the preparation, the volume occupied by the medication after 30 days, the medication residue volume and the volume of the canal after medication removal. The residue percentage was also calculated in relation to the volume of the canal and the volume of medication found after 30 days. Finally, the volume increase of the canal after medication removal was also assessed. Data were analyzed using threefactor ANOVA/Tukey test or Kruskal-Wallis/Student-Newman-Keuls with overall significance level of 5% Results: Regardless of the region, the use of ultrasound resulted in a smaller volume of residue in absolute terms and in relation to the volume of the canal. In relation to the volume of medication after 30 days, the use of ultrasound was only marginally significant. The use of an additional instrument showed no statistically significant influence on the effectiveness of MIC removal. The percentage of residue was higher in the apical region, when the ultrasound was not used. In absolute numbers, the cervical region showed the highest volume of residue. In relation to the control group, the use of ultrasound resulted in a higher final volume in the cervical third. All techniques resulted in statistically similar increases in the volume of the surgical canal for the cervical and middle thirds. In the apical third, the control group showed a statistically lower increase in volume than the others thirds. Conclusions: Statistically significant differences were found among the tested techniques, the use of ultrasound resulted in a smaller volume of residue in all groups for a particular third.
133

Efeito da terapia de longa duração com ácido zoledrônico no osso esponjoso da mandíbula e fêmur de ratos Wistar / Effect of long-term zoledronic acid treatment on cancellous bone in the mandible and femur of Wistar rats

Mariana Quirino Silveira Soares 09 October 2017 (has links)
Os bisfosfonatos (BF) são amplamente utilizados no tratamento de doenças osteolíticas como metástases ósseas e osteoporose. A osteonecrose dos maxilares associada ao uso de BF (OMAB) é caracterizada pela presença de osso exposto ou que pode ser sondado através de uma fístula que persiste por mais de oito semanas em pacientes com história de terapia de BF e sem história de radioterapia na região de cabeça e pescoço e/ou sem doença metastática nos maxilares. A incidência de OMAB aumenta com a potência, duração do tratamento e dose de BF recebida. Até o presente momento, a fisiopatologia da OMAB não está clara, dificultando a prevenção e o tratamento. O objetivo deste estudo foi avaliar o efeito da administração de altas doses Ácido Zoledrônico (AZ) por período prolongado no osso esponjoso da mandíbula e da metáfise proximal do fêmur de ratos Wistar. Para relacionar as descobertas à fisiopatologia da OMAB, o regime de administração de BF de um modelo animal relevante desta lesão foi reproduzido. Seis animais receberam AZ (0,6 mg / kg) e seis receberam solução salina no mesmo volume (Controles). Os compostos foram administrados por via intraperitoneal em cinco doses a cada 28 dias. A eutanásia dos animais ocorreu após 150 dias de início da terapia. As hemimandíbulas e fêmures direitos foram escaneados usando Micro-tomografia computadorizada (Micro-CT) de alta resolução (14 m). Para a primeira análise realizada neste estudo, os dados morfométricos do osso esponjoso foram calculados na região do segundo e primeiro molar na mandíbula e na metáfise do fêmur usando CTAnalyzer (Bruker, Bélgica). Para a segunda análise, cinco amostras de hemimandíbulas de cada grupo foram cortadas em lâminas histológicas (5 m) e coradas com Hematoxilina e Eosina. Para comparar os parâmetros morfométricos na Micro-CT e histologia, as imagens de Micro-CT foram espacialmente alinhadas à histologia. Os dados morfométricos do osso alveolar foram calculados usando o software CTAnalyzer (Bruker, Bélgica) na região entre as raízes mesial e distal do primeiro molar. A densidade da área vascular (área vascular/área total; VA/TA) e os dados histomorfométricos ósseos foram estimados usando Axiovision na mesma região (entre as raízes mesial e distal do primeiro molar). Foi adotada significância estatística de 5% ( = 0,05). Os animais tratados com AZ apresentaram aumento significativo na porcentagem de volume ósseo (p <0,05) com trabéculas mais espessas, osso mais compacto com menor separação trabecular na mandíbula e no fêmur. Na mandíbula, o aumento da densidade óssea e diminuição da separação trabecular foram fortemente correlacionados com a diminuição da área vascular observada no grupo AZ (p <0,05). Em conclusão, o tratamento de longa duração com altas doses de AZ foi significativamente associado ao aumento na densidade óssea e à diminuição dos espaços medulares, canais nutritivos e vasculatura do osso alveolar. A análise com Micro-CT revelou alterações semelhantes na estrutura óssea tanto na mandíbula quanto no fêmur do grupo AZ. / Bisphosphonates (BFs) are widely used in the treatment of osteolytic diseases such as bone metastases and osteoporosis. The osteonecrosis of the jaws related to BF (ONB) is characterized by the presence of exposed bone or bone that can be probed through a fistula that persists for more than eight weeks in patients with a history of BF therapy and without history of head and neck radiotherapy and / or without metastatic disease in the jaws. The incidence of ONB increases with potency, duration of treatment and dose of BF received. Thus far, the pathophysiology of ONB is unclear, hampering prevention and treatment. The aim of this study was to objectively assess the effect of long-term high-dose Zoledronic Acid (ZA) on cancellous bone in the jaw and femur of Wistar rats. In order to link our findings to the physiopathology of ONB, the therapeutic regiment of a relevant ONB animal model was reproduced. Twelve Wistar rats were randomly divided in two groups: six received Zoledronic acid (ZA; 0.6 mg / kg) and six (Controls) received saline solution in the same volume. The compounds were administrated intraperitoneally in five doses each 28 days. The rats were killed after 150 days of the therapy onset. Mandibles and femurs were scanned using a high-resolution (14m) micro-computerized tomography (Micro-CT). For the first analysis carried in this study, cancellous bone morphometric data were calculates in the region of the second and first molar in the mandible and in the proximal femur using CTAnalyzer (Bruker, Belgium). For the second analysis five samples were cut into histological slices (5m) and stained with Hematoxylin and Eosin. In order to compare the same morphological structures in Micro-CT and histology, the Micro-CT images were aligned to histology. Alveolar bone morphometric data (Micro-CT) was calculated using CTAnalyzer (Bruker, Belgium) in the region between the mesial and distal roots of the first molar. Blood vessels density and bone histomorphometric data were calculated using Axiovision (Carl Zeiss, Germany) in the same region used for Micro-CT evaluation. Statistical significance of 5% (=0.05) was adopted. ZA treated rats presented significant increase in the percentage of bone volume (p<0.05) with thicker trabeculae and more compact bone with smaller marrow spaces in the mandible and femur. In the mandible, the increase in bone density and decrease of marrow spaces size was strongly correlated with the decrease in the vascular area noticed in the ZA group (p<0.05). In conclusion, long-term high-dose ZA treatment was significant associated with the increase of bone density and the diminution of medullary spaces and nutritive canals size as well as decrease in vascularity of the alveolar bone. Micro-CT investigation showed similar changes in bone structure in the mandible and femur in the ZA group.
134

Limpeza e modelagem de canais ovais após preparo químico-mecânico utilizando três sistemas de instrumentação e irrigação com hipoclorito de sódio: estudo correlativo usando microtomografia computadorizada e histologia

Lacerda, Mariane Floriano Lopes Santos 31 March 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2018-02-28T14:32:12Z No. of bitstreams: 1 marianeflorianolopessantoslacerda.pdf: 10232685 bytes, checksum: 43a6424d223e0874ce221a2e6565b3ef (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-03-01T15:58:28Z (GMT) No. of bitstreams: 1 marianeflorianolopessantoslacerda.pdf: 10232685 bytes, checksum: 43a6424d223e0874ce221a2e6565b3ef (MD5) / Made available in DSpace on 2018-03-01T15:58:28Z (GMT). No. of bitstreams: 1 marianeflorianolopessantoslacerda.pdf: 10232685 bytes, checksum: 43a6424d223e0874ce221a2e6565b3ef (MD5) Previous issue date: 2017-03-31 / PROQUALI (UFJF) / Objetivos: O presente estudo se propôs a avaliar a limpeza e modelagem de canais ovais após preparo com 3 sistemas de instrumentação usando correlação entre método analíticos. Materiais e métodos: Raízes distais de molares inferiores com canais ovais e vitalidade pulpar foram inicialmente escaneadas por microtomografia computadorizada (micro-CT) para seleção e distribuição das amostras em três grupos experimentais de acordo com o instrumento a ser avaliado: selfadjusting files (SAF), TRUShape e XP-endo Shaper. Em todos os grupos, hipoclorito de sódio a 5,25% aquecido a 37°C foi o irrigante. Após novo escaneamento em micro-CT, as áreas não tocadas das paredes do canal foram calculadas e, em seguida, avaliadas histologicamente quanto à quantidade de remanescente pulpar nos terços radiculares. Resultados: A 4mm do ápice, SAF apresentou valor significativamente menor de paredes não tocadas em relação ao XP-endo Shaper (P<0,049). Não foi possível verificar diferença estatística a 10 mm do ápice (P>0,05). A quantidade de remanescentes pulpares não apresentou diferença significativa entre os instrumentos, em nenhum dos terços avaliados. Não houve correlação significativa entre área não tocada e remanescente pulpar para os instrumentos testados. Conclusão: Não houve diferença no percentual de paredes não tocadas entre os 3 grupos, exceto entre SAF e XP-endo Shaper na avaliação dos 4 mm apicais. Também não houve diferença significativa na limpeza das paredes não tocadas. A não correlação entre paredes não tocadas e a quantidade de remanescentes pulpares indica a eficácia do preparo químico-mecânico com hipoclorito de sódio como irrigante na eliminação de matéria orgânica sobre as paredes. / Purpose: The present study evaluated the cleaning and shaping ability of three instrumentation systems in oval canals of vital teeth using a correlative analytical approach. Materials and methods: Distal roots of oval canals with pulp vitality were scanned by computed microtomography (micro-CT) for sample selection and distribution into three experimental groups according to the instrument to be evaluated: self-adjusting files (SAF), TRUShape and XP-endo Shaper. In all groups, the irrigant was sodium hypochlorite (5.25%) heated at 37°C. After rescanning by micro-CT, the untouched walls were measured and then histologically evaluated for the amount of pulp remaining in the root thirds. Results: SAF was more effective in touching the walls at 4 mm from the apex, presenting a significantly lower value of untouched walls when compared to XPendo Shaper (P <0.049). However, it was not possible to verify significant differences in the full canal length between groups. The amount of pulp remnants also did not differ between instruments in the canal thirds. There was no significant correlation between untouched areas and pulp remnants for any instrument. Conclusion: There was no significant difference in the amount of untouched walls between instruments, except between SAF and XP-endo Shaper in the apical 4 mm. There was no significant difference in the cleaning ability either. The non-correlation between untouched walls and pulp remnants indicates the effectiveness of different instruments and sodium hypochlorite irrigation in the elimination of soft tissue from unprepared walls.
135

Qualidade de rebordos alveolares preservados e sua influência na estabilidade primária e secundária do implante: resultados preliminares de um estudo clínico-microtomográfico controlado e randomizado

Resende, Maraísa Aparecida Pinto 19 September 2018 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2018-11-22T11:04:41Z No. of bitstreams: 1 maraisaaparecidapintoresende.pdf: 6162684 bytes, checksum: 81f875f5effd371befe15f0ee40da393 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-11-23T12:58:47Z (GMT) No. of bitstreams: 1 maraisaaparecidapintoresende.pdf: 6162684 bytes, checksum: 81f875f5effd371befe15f0ee40da393 (MD5) / Made available in DSpace on 2018-11-23T12:58:47Z (GMT). No. of bitstreams: 1 maraisaaparecidapintoresende.pdf: 6162684 bytes, checksum: 81f875f5effd371befe15f0ee40da393 (MD5) Previous issue date: 2018-09-19 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo clínico controlado randomizado microtomográfico foi comparar a qualidade óssea entre dois métodos diferentes de preservação do rebordo alveolar e avaliar as estabilidades primária e secundária dos implantes instalados nessas regiões. Vinte pacientes foram divididos aleatoriamente em dois grupos de tratamento após uma única extração dentária. Dez alvéolos foram enxertados com fosfato de cálcio bifásico (SBC, n = 10) associado a um retalho de tecido conjuntivo subepitelial pediculado para o fechamento primário. Dez alvéolos foram selados com uma restauração provisória de pôntico ovóide (PROV, n = 10) sem material de enxertia. Após 12 meses, 9 pacientes perderam-se no acompanhamento e 11 pacientes receberam implantes dentários. As biópsias ósseas foram avaliadas por microtomografia computadorizada (8 μm), quanto às características do osso trabecular. Valores de torque de inserção (ITV) e quociente inicial de estabilidade do implante (ISQI) foram registrados no momento da instalação dos implantes. O ISQ também foi registrado aos 7 dias, 30 dias e 60 dias pós-operatórios. Todos os onze pacientes tiveram os implantes osseointegrados sem intercorrências. O grupo PROV apresentou trabéculas mais espessas (0,17 ± 0,03) em relação ao grupo SBC (0,11 ± 0,03) (p = 0,03). O osso trabecular foi mais anisotrópico em PROV (0,3 ± 0,08) comparado com SBC (0,1 ± 0,07) (p = 0,01). O grupo PROV apresentou menor superfície óssea (26,02 ± 10,36) que o grupo SBC (40,09 ± 10,94) (p = 0,05). Além disso, o PROV apresentou ISQ inicial mais alto (72,3 ± 21) em comparação com o SBC (67 ± 3,9) (p = 0,05). O osso trabecular revelou diferenças na microarquitetura entre os dois métodos de preservação do rebordo alveolar e ambos os métodos foram satisfatórios para a instalação do implante e resultaram em altos valores de ITV e ISQ. / This randomized controlled clinical microtomographic trial aimed to compare the bone quality between two different methods of alveolar ridge preservation and to evaluate the primary and secondary implant stability. Twenty patients were randomly divided into two groups following a single tooth extraction: SBC group (n=10), sockets were grafted with alloplastic biphasic calcium phosphate and a pedicle subepithelial connective tissue flap was used for primary closure; and PROV group (n=10), sockets were sealed with an ovate pontic provisional restoration. After 12 months, 11 patients received dental implants, with nine patients lost to follow-up. Bone biopsies were evaluated by microcomputed-tomography (8 μm) to determine cancellous bone characteristics. Insertion torque values (ITV) and initial implant stability quotient (ISQI) were recorded at installation. The ISQ was also recorded 7, 30 and 60 days after the implant was installed. All implants showed uneventful osseointegration. The PROV group presented thicker trabeculae (0.17±0.03) compared to the SBC group (0.11±0.03; p 0.03). Trabeculae bone was more anisotropic in the PROV group (0.3±0.08) compared with the SBC group (0.1±0.07; p 0.01). The PROV group presented less bone surface (26.02±10.36) than the SBC group (40.09±10.94; p 0.05). Also, PROV showed higher ISQI (72.3±21) than SBC (67±3.9; p 0.05). The characteristics of the trabecular bone differed between the two alveolar ridge preservation methods and the both preservation methods gave satisfactory results with regard to implant placement, and both resulted in high values for ITV and ISQ.
136

Análise em microtomografia computadorizada do preparo e obturação em canais mesiais de molares inferiores /

Pinto, Jáder Camilo. January 2018 (has links)
Orientador: Mário Tanomaru Filho / Resumo: Objetivo: Avaliar preparo e dilatação adicional com instrumentos de NiTi tratados termicamente em movimento rotatório ou reciprocante, capacidade de preenchimento pelas técnicas de onda contínua de condensação (OCC) ou compactação lateral (CL) e por OCC com cimentos AH Plus (AHP) ou Neo MTA Plus (NMTAP) em raízes mesiais de molares inferiores. Metodologia: Molares inferiores com dois canais radiculares e curvatura entre 20° e 40° foram preparados (n=24) por ProDesign Logic (PDL) 25.01 e 25.06 em movimento rotatório e ProDesign R (PDR) 25.06 em movimento reciprocante. Dilatação adicional foi realizada com PDL35.01 e PDL35.05 ou PDR35.05. Canais preparados por PDL35.05 foram obturados (n=12) por CL ou OCC, associados a AHP. Canais preparados por PDR35.05 foram obturados por OCC e AHP ou NMTAP. Escaneamentos com 9 µm foram realizados com Micro-CT (SkyScan 1176) antes e após o preparo, após a dilatação adicional e após a obturação. Percentual de aumento volumétrico (%AV), debris (%D) e superfície não instrumentada (%SNI), transporte, centralização e tempo de preparo foram analisados. Análises volumétricas foram realizadas para determinação do percentual de material obturador e de falhas como um todo e em cada terço dos canais radiculares. Os testes estatísticos ANOVA e Tukey ou Kruskall-Wallis e Dunn foram realizados (P<0,05). Publicação 1 - Resultados: PDL25.06 promoveu maior %AV no terço apical e menor %D e %SNI em comparação ao PDR25.06 (P<0,05). Após dilatação adicional PDL35... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: The aim of this study was to evaluate root canal preparation and additional enlargement using NiTi instruments thermally treated in rotary or reciprocating motion, filling capacity by continuous wave of condensation (CWC) or lateral compaction (LC) and CWC using AH Plus (AHP) or Neo MTA Plus (NMTAP) in mesial roots of mandibular molars. Methods: Mesial roots of mandibular molars, degree of curvature between 20° and 40°, were prepared (n=24) by ProDesign Logic (PDL) 25.01 and 25.06 in rotating motion or ProDesign R (PDR) 25.06 in reciprocating motion. Additional enlargement was performed using PDL 35.01 and 35.05 or PDR 35.05. Root canals prepared by PDL 35.05 were filled (n=12) by LC or CWC, associated with AHP. Root canals prepared by PDR 35.05 were filled by CWC associated with AHP or NMTAP. Scanning with 9μm resolution were performed by Micro-CT (SkyScan 1176) before and after preparation, after additional enlargement and after filling. Percentage increase in volume (%VI), debris (%D) and uninstrumented surface (%US), root canal transportation, centralization and preparation time were analysed. Volumetric analyzes were performed to determine the percentage of obturator material and voids as a whole and in each third of the root canals. ANOVA and Tukey or Kruskal-Wallis and Dunn tests were used (α=0.05). Publication 1 - Results: PDL 25.06 promoted higher %VI in the apical third and lower %D and %US compared to PDR 25.06 (P<0.05). After additional enlargement, ... (Complete abstract click electronic access below) / Mestre
137

Avaliação por microtomografia de raio-X do reparo ósseo em osteotomia completa de tíbia de ratos após tratamento com ultrassom de baixa intensidade e laser de baixa potência / Assessment of bone repair by x-ray microtomography in complete Tiba rats osteotomy after low-intensity pulsed ultrasound and low-level laser therapy

Alessandra Rossi Paolillo 12 December 2013 (has links)
As fraturas são consideradas um dos maiores problemas de saúde pública pelo custo e morbidade a elas associados. O objetivo deste estudo foi investigar os efeitos do ultrassom de baixa intensidade (LIPUS) e do laser de baixa potência (LLLT) sobre o reparo ósseo de tíbia de ratos (Wistar) utilizando a microtomografia por raio-x (&#956CT) e a análise histomorfométrica. Uma osteotomia total no terço médio foi fixada com fio de Kirschner (0,89 mm) e utilizado um espaçador polimérico de 2 mm de espessura e 1 mm de diâmetro entre os fragmentos proximal e distal para induzir retardo de consolidação da fratura. Foram utilizados 24 animais separados aleatoriamente em 4 grupos experimentais: Grupo Controle: sem tratamento do retardo da consolidação (n = 5); Grupo Laser: tratamento da fratura com laser (n = 6); Grupo LIPUS: tratamento da fratura com LIPUS (n = 7) e; Grupo LIPUS + Laser: tratamento da fratura com LIPUS e Laser (n = 7). Os tratamentos com LIPUS e/ou Laser foram iniciados após 5 semanas da cirurgia e realizados durante 5 dias consecutivos de tratamento, seguidos por 2 dias sem serem tratados até totalizarem 12 sessões terapêuticas. Os parâmetros de irradiação laser foram: 808 nm; 100 mW; 2500 mW/cm² , 125 J/cm² durante 50 segundos. Os parâmetros do LIPUS foram: 1,5 MHz, ciclo de trabalho 1:4, intensidade de 30 mW/cm², 20 minutos por sessão. Quando as duas técnicas foram associadas, o laser foi aplicado perpendicularmente ao LIPUS no décimo minuto de aplicação do LIPUS. Radiografias da tíbia foram feitas para acompanhar a evolução da fratura após a cirurgia, antes dos tratamentos e antes da eutanásia. Após a eutanásia foram realizadas avaliações microtomográficas por raio-x e histomorfométricas para análise do reparo ósseo. Na análise microtomográfica do reparo ósseo o tecido neoformado de reparo (calo ósseo) e o tecido normal não foram isolados. Na análise estatística foi utilizada a ANOVA one-way com posthoc de Tukey. Não foi constatada diferença significativa para maioria das variáveis, exceto para o fator padrão trabecular (Tb.Pf) no grupo LIPUS+Laser comparado aos grupos LIPUS (p = 0.02), Laser (p = 0.02) e Controle (p = 0.01), para a conectividade (Conn) no grupo Laser comparada ao grupo Controle (p = 0.04) e para a densidade de conectividade (D.Conn) no grupo LIPUS+Laser comparado ao grupo Controle (p = 0.04). As imagens histológicas mostram maior quantidade de tecido esponjoso no grupo LIPUS+Laser. Parâmetros morfométricos e histomorfométricos não revelaram um avanço do reparo ósseo na comparação entre os grupos com tratamento em relação ao grupo controle provavelmente devido a não reabsorção do espaçador polimérico pelo organismo dos animais. A &#956CT é uma técnica de grande potencial que permite análises qualitativas e quantitativas e reconstruçoes 2D e 3D. / Bone fractures are important public health problems due to the morbidity and high cost related to them. The aim of this study was to evaluate the effects of low pulsed intensity ultrasound (LIPUS) and infrared low level laser therapy (LLLT) in the bone repair of a transverse rat tibia osteotomy with assessement by x-ray microtomography (&#956CT) and histomorphometry. An easily implemented transverse osteotomy with a Kirchner wire and 2 mm width polymeric spacer beads established a delayed union in the fracture. Twenty four rats were divided into four experimental groups: Control Group - untreated; Laser Group - treated with infrared LLLT; LIPUS Group treated with low intensity pulsed ultrasound; LIPUS+Laser Group - treated with low intensity pulsed ultrasound and infrared LLLT. The treatments with infrared LLLT (808 nm, 100 mW, 2500 mW/cm², 125 J/cm², 50 seconds) and LIPUS (1,5 MHz, 1:4 duty cicle, 30 mW/cm², 20 minutes) started 5 weeks after the surgery following a sequence of 5 days on and 2 days off until 12 sessions were reached. When LLLT and LIPUS therapies were used simultaneously there was a 90º angle between the laser and the ultrasound beams. The surgical technique and the bone repair were assessed by x-ray radiography. One-way analysis of variance (one-way ANOVA) and Tukey post-hoc were used for statistical analysis. The normal bone and the callus were kept together in the &#956CT analysis. There was no significant difference between treatments results except for the parameters trabecular pattern factor - Tb.Pf [US+Laser group x LIPUS group (p = 0.02); US+Laser group x Laser group (p = 0.02) and US+Laser group x Control group (p = 0.01)], connectivity - Conn [Laser group x Control group (p = 0.04)] and connectivity density D.Conn [US+Laser group x Control group (p = 0.04)]. The histology showed greater amount of spongeous bone in the LIPUS+Laser group. The morphometric and histomorphometric assessments didn´t show a faster bone repair when treated groups were compared against the control one. The non absorption of the polymeric spacer bead is probably the reason of these findings. The &#956CT is a powerful technique that allows 2D and 3D quantitative analysis and reconstructions.
138

Análise do preparo, limpeza, desinfecção e obturação de canais radiculares de molares inferiores por diferentes protocolos e materiais /

João, Mariana Mena Barreto Pivoto January 2019 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Resumo: Este estudo avaliou o preparo, limpeza e obturação de canais radiculares de molares inferiores por diferentes protocolos e materiais. Canais mesiais (n=48) de molares inferiores curvos (20°- 40°) foram preparados usando ProDesign Logic (PDL) até 25/.06 ou HyFlex EDM (HFEDM) 25/.08, e até PDL-40/.05 ou HFEDM-40/.04 na ampliação (Publicação 1). A irrigação final foi realizada com irrigação ultrassônica passiva-PUI ou easy clean-EC, hipoclorito de Sódio-NaOCl ou clorexidina-CLX ou água destilada (n=8): PUI/NaOCl2,5%; EC/NaOCl2,5%; EC/água destilada; PUI/CLX 2%; PUI/NaOCl 1%; PUI/NaOCl 2,5% (Publicação 2). A obturação foi realizada por condensação lateral-CL ou Termo Pack II e AHP (Publicação 3); cone único (CU) com nMTAP ou TFBC (Publicação 4). Escaneamentos (9 μm) foram realizados antes e após cada etapa experimental. Percentual de aumento volumétrico (%AV), debris (%D), redução de debris (%RD), superfície não instrumentada (%SNI), centralização, material obturador (%MO) e falhas (%F) foram analisados em toda a extensão do canal (total) e nos terços dos canais radiculares. Testes ANOVA e Tukey ou Kruskal-Wallis e Dunn, e T Pareado foram realizados (α = 0,05). HFEDM-25/.08 promoveu maior % AV. Após a dilatação, HFEDM apresentou maior volume (P < 0,05) e houve redução de %D e %SNI. Os sistemas produziram canais centralizados (Publicação 1). Houve diminuição do percentual e volume de debris acumulados após as técnicas e entre o PUI com diferentes soluções irrigantes. EC/NaOCl prop... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
139

Preparo e obturação de canais distais achatados de molares inferiores : análise por microtomografia computadorizada /

Santos Júnior, Airton Oliveira. January 2020 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Resumo: Objetivo: Avaliar o preparo com instrumentos de níquel-titânio tratados termicamente em movimento rotatório ou reciprocante e a associação com inserto ultrassônico e capacidade de preenchimento pelas técnicas híbrida de Tagger ou cone único empregando o cimento Bio-C Sealer em canais radiculares achatados. Metodologia: Canais distais achatados de molares inferiores com diâmetro vestíbulo-lingual igual ou maior que 4 vezes o diâmetro mésio-distal foram preparados (n=12) por Reciproc Blue (RB) R40 em movimento reciprocante ou ProDesign Logic (PDL) 40.01 e 40.05 em movimento rotatório. Etapa complementar de instrumentação foi realizada com inserto ultrassônico Flatsonic nos dois grupos. Os canais foram obturados (n=12) pela técnica híbrida de Tagger ou cone único com o cimento Bio-C Sealer. Escaneamentos em resolução de 8,74 µm foram realizados em microtomografia computadorizada (micro-CT) antes e após todas as etapas experimentais. Percentual de aumento volumétrico, debris e superfície não instrumentada foram analisados para as etapas de preparo e percentual de falhas para obturação. Testes estatísticos ANOVA e Tukey, teste t pareado e não pareado foram realizados com nível de significância de 5%. Publicação 1 – Resultados: O percentual de aumento volumétrico, debris e superfície não instrumentada foi semelhante entre RB e PDL na extensão total do canal (P>0,05). PDL promoveu menor percentual de debris no terço cervical e menor percentual de aumento volumétrico no terço apical ... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
140

Análise por microtomografia computadorizada do preparo e obturação de canais radiculares achatados de segundos pré-molares superiores /

Tavares, Karina Ines Medina Carita. January 2020 (has links)
Orientador: Mario Tanomaru Filho / Resumo: Objetivo: Avaliar o preparo empregando dois sistemas rotatórios de níquel-titânio tratados termicamente e efeito do novo inserto ultrassônico e instrumento de menor diâmetro e a capacidade de preenchimento dos cimentos Bio-C Sealer ou AH Plus pela técnica de cone único em canais radiculares achatados de segundos pré-molares superiores. Metodologia: Canais radiculares achatados de segundos pré-molares superiores humanos com diâmetro vestíbulo-lingual igual ou maior que 4 vezes o diâmetro mésio-distal foram preparados com sistemas rotatórios(n=16): ProDesign Logic (PDL) 30.01 e 30.05 ou HyFlex EDM (HEDM) 10.05 e 25.08. Etapa do preparo complementar foi realizada com inserto ultrassônico Flatsonic (terço cervical e médio) e PDL 25.03 (terço apical) (FPDL) em ambos os grupos. Os canais radiculares foram obturados (n=16) com o cimento Bio-C Sealer ou AH Plus pela técnica de cone único. Escaneamentos em resolução de 8,74 µm foram realizados em microtomografia computadorizada (micro-CT) antes e após as etapas experimentais. Percentual de aumento volumétrico, debris e superfície não instrumentada foram analisados para as etapas de preparo e percentual de falhas para obturação. Os testes estatísticos específicos para o preparo e obturação foram realizados com nível de significância de 5%. Publicação 1 – Resultados: Não houve diferença estatística entre PDL e HEDM para o aumento de volume, debris e superfície não instrumentada no canal como um todo (P>0,05). PDL obteve maior percentual... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The aim of this study was to evaluate root canal preparation using two rotary nickel-titanium systems thermally treated and the effect of ultrasonic tip and small diameter instrument; and the filling capacity of sealers Bio-C Sealer and AH Plus by single cone technique in flattened root canals of maxillary second premolars. Methods: Flattened root canals of human maxillary second premolars with buccolingual diameter 4 or more times larger than the mesiodistal diameter were prepared with rotary systems (n=16): ProDesign Logic (PDL) 30.01 e 30.05 or HyFlex EDM (HEDM) 10.05 e 25.08. Complementary preparation step was performed with ultrasonic tip Flatsonic (cervical and middle thirds) and PDL 25.03 (apical third) (FPDL) in both groups. The root canals were filled (n=16) with Bio-C Sealer or AH Plus by single cone technique. Scanning in resolution of 8,74 µm were performed by microcomputed tomography (micro-CT) before and after the experimental steps. Percentage of increase in volume, debris and uninstrumented surface were analysed for the preparation steps and percentage of voids for obturation. The statistical tests specific to preparation and obturation analyses were performed with a significance level of 5%. Publication 1 - Results: There was no statistically difference between PDL and HEDM for volume increase, debris and uninstrumented surface, in entire canal (P>0,05). PDL showed higher debris in the middle and apical thirds than HEDM (P<0,05). The FPDL protocol ... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0527 seconds