• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Mesure de Température par Méthodes Multi-Spectrales et Caractérisation Thermique de Matériaux Anisotropes par Transformations Intégrales : « Aspects Théoriques et Expérimentaux » / Temperature Measurement by Multi-Spectral Methods and Thermal Characterization of Anisotropic Materials by Integral Transforms : "Theoretical and experimental aspects"

Rodiet, Christophe 17 July 2014 (has links)
Ce mémoire est constitué de deux parties relativement indépendantes, dont la première partie porte sur les méthodes de mesure de température par méthodes Multi-Spectrales (pyrométrie optique passive), et la seconde sur la Caractérisation Thermique à haute température par transformations intégrales de matériaux orthotropes. Dans chacune de ces deux parties, les méthodes/modèles développés ont été traités du point de vue théorique, numérique, et expérimental. Dans la partie multi-spectrale, une méthode de mesure de température permettant de prendre en compte les variations spectrales de la chaine de mesure globale (incluant l’émissivité) a été présentée. De plus, une méthode de détermination des longueurs d’ondes optimales au sens de la minimisation de l’écart-type sur la température, a été développée. Enfin, il a également été montré que les longueurs d’ondes optimales pour les mesures mono-spectrales et bi-spectrales pouvaient être déterminées à l’aide de lois analogues à la loi de déplacement de Wien. Dans la partie Caractérisation Thermique, différentes méthodes et modèles ont été développés. Les méthodes proposées effectuent l’estimation des diffusivités longitudinales et transversales sur l’ensemble des harmoniques simultanément. De plus, ces méthodes permettent de s’affranchir du couplage thermique dû à la présence d’un porte-échantillon, et/ou d’effectuer des mesures de diffusivités pseudo-locales, en injectant comme conditions aux limites les informations expérimentales obtenues par caméra infrarouge. Enfin, les notions de corrélation entre les paramètres et de durée d’exploitabilité des harmoniques ont également été abordées / This thesis consists of two relatively independent parts, the first part focuses on methods of temperature measurement using Multi-Spectral (passive optical pyrometry) methods, and the second on the Thermal Characterization by integral transforms at high temperature of orthotropic materials. In each of these two parts, methods / models developed were treated from a theoretical point of view, numerical and experimental. In the multi-spectral part, a method of temperature measurement to take into account a spectral variation of the overall measurement chain (including the emissivity) was introduced. Moreover, a method of determining the optimal wavelengths in the sense of minimizing the standard deviation of temperature, has been developed. Finally, it has also been shown that the optimal wavelengths for mono-spectral and bi-spectral measurements could be determined with similar laws to Wien's displacement law. In the Thermal Characterization part, different methods and models have been developed. The proposed methods perform the estimation of longitudinal and transverse diffusivities on all harmonics simultaneously. Furthermore, they allow overcoming the thermal coupling due to the presence of a sample holder, and / or making pseudo-local measurements of diffusivities. Finally, the concepts of correlation between parameters and duration of harmonics exploitability were also discussed.This thesis consists of two relatively independent parts, the first part focuses on methods of temperature measurement using Multi-Spectral (passive optical pyrometry) methods, and the second on the Thermal Characterization by integral transforms at high temperature of orthotropic materials. In each of these two parts, methods / models developed were treated from a theoretical point of view, numerical and experimental. In the multi-spectral part, a method of temperature measurement to take into account a spectral variation of the overall measurement chain (including the emissivity) was introduced. Moreover, a method of determining the optimal wavelengths in the sense of minimizing the standard deviation of temperature, has been developed. Finally, it has also been shown that the optimal wavelengths for mono-spectral and bi-spectral measurements could be determined with similar laws to Wien's displacement law. In the Thermal Characterization part, different methods and models have been developed. The proposed methods perform the estimation of longitudinal and transverse diffusivities on all harmonics simultaneously. Furthermore, they allow overcoming the thermal coupling due to the presence of a sample holder, and / or making pseudo-local measurements of diffusivities. Finally, the concepts of correlation between parameters and duration of harmonics exploitability were also discussed
2

Mesure de la température à l'échelle microscopique par voie optique dans la gamme ultraviolet-visible / Microscale temperature measurements by optical way in the ultraviolet-visible range

Pierre, Thomas 10 December 2007 (has links)
Cette étude porte sur la mesure de la température à l’échelle microscopique par voie optique dans la gamme UV-visible par comptage de photons à l’aide d’un PMT refroidi. À partir des avantages et des inconvénients de chaque technique existante, la première partie permet de comprendre les orientations de nos travaux. Le Second Chapitre montre et insiste sur l’intérêt de travailler aux courtes longueurs d’onde (limite de diffraction, précision sur la mesure...), d’utiliser la méthode multi-spectrale pour s’affranchir de paramètres inconnus (e.g. l’émissivité) en choisissant judicieusement les longueurs d’onde de travail, ainsi que les lois statistiques classiques pour mesurer le flux photonique sachant son émission aléatoire. Le Chapitre Trois présente le banc de mesure (microscope optique, système de mesure du flux photonique...) et une attention toute particulière est portée sur la conception des éléments chauffants servant à l’étalonnage. Le Quatrième Chapitre présente les résultats en températures obtenues à l’aide des lois statistiques. Ils valident le bon fonctionnement du dispositif, la mise au point de la zone microscopique, et l’intérêt de bien modéliser les filtres monochromatiques. Enfin, des améliorations sur la précision de la mesure (réseau de diffraction, analyseur multi-canal) et pour mesurer des températures plus faibles (LIF, méthode corrélation temporelle) sont présentées dans le Cinquième Chapitre / The aim of this study is to measure microscale temperature by optical way in the UV-visible range by photons counting using a cooled PMT. From the existing techniques advantages and disadvantages, this first part allows to understand the choices of this study. The second part shows and underlines the interest in working in short wavelengths (diffraction limit, measurement accuracy), in using the multi-spectral method to get rid of unknown parameters (e.g. emissivity) by choosing judicious working wavelengths, as well as the statistic laws to measure the photonic flux knowing its random emission. The third chapter presents the optical bench (optical microscope, photonic flux measurement facility…). A particularly attention is given to the design of the heated elements, which allow to calibrate the facility. The fourth part exposes the temperature results obtained through statistic laws. They validate the well-running of the facility, the microscopic area focusing, and the interest to model correctly the filters. Finally, measurement accuracy improvements (diffraction grating, multi-channel analyzer) and lower temperature measurement techniques (LIF, time-correlated method) are presented in the fifth part

Page generated in 0.0604 seconds