• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 33
  • 33
  • 12
  • 10
  • 8
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

The Effect of Core Stability on Running Mechanics in Novice Runners

Raabe, Margaret E. 16 June 2017 (has links)
No description available.
32

Caractérisation tridimensionnelle de l’amplitude articulaire de l’épaule

Haering, Diane 09 1900 (has links)
L’épaule est l’articulation la plus mobile et la plus instable du corps humain dû à la faible quantité de contraintes osseuses et au rôle des tissus mous qui lui confèrent au moins une dizaine de degrés de liberté. La mobilité de l’épaule est un facteur de performance dans plusieurs sports. Mais son instabilité engendre des troubles musculo-squelettiques, dont les déchirures de la coiffe des rotateurs sont fréquentes et les plus handicapantes. L’évaluation de l’amplitude articulaire est un indice commun de la fonction de l’épaule, toutefois elle est souvent limitée à quelques mesures planaires pour lesquelles les degrés de liberté varient indépendamment les uns des autres. Ces valeurs utilisées dans les modèles de simulation musculo-squelettiques peuvent amener à des solutions non physiologiques. L’objectif de cette thèse était de développer des outils pour la caractérisation de la mobilité articulaire tri-dimensionnelle de l’épaule, en passant par i) fournir une méthode et son approche expérimentale pour évaluer l’amplitude articulaire tridimensionnelle de l’épaule incluant des interactions entre les degrés de liberté ; ii) proposer une représentation permettant d’interpréter les données tri-dimensionnelles obtenues; iii) présenter des amplitudes articulaires normalisées, iv) implémenter une amplitude articulaire tridimensionnelle au sein d’un modèle de simulation numérique afin de générer des mouvements sportifs optimaux plus réalistes; v) prédire des amplitudes articulaires sécuritaires et vi) des exercices de rééducation sécuritaires pour des patients ayant subi une réparation de la coiffe des rotateurs. i) Seize sujets ont été réalisé séries de mouvements d’amplitudes maximales actifs avec des combinaisons entre les différents degrés de liberté de l’épaule. Un système d’analyse du mouvement couplé à un modèle cinématique du membre supérieur a été utilisé pour estimer les cinématiques articulaires tridimensionnelles. ii) L’ensemble des orientations définies par une séquence de trois angles a été inclus dans un polyèdre non convexe représentant l’espace de mobilité articulaire prenant en compte les interactions entre les degrés de liberté. La combinaison des séries d’élévation et de rotation est recommandée pour évaluer l’amplitude articulaire complète de l’épaule. iii) Un espace de mobilité normalisé a également été défini en englobant les positions atteintes par au moins 50% des sujets et de volume moyen. iv) Cet espace moyen, définissant la mobilité physiologiques, a été utilisé au sein d’un modèle de simulation cinématique utilisé pour optimiser la technique d’un élément acrobatique de lâcher de barres réalisée par des gymnastes. Avec l’utilisation régulière de limites articulaires planaires pour contraindre la mobilité de l’épaule, seulement 17% des solutions optimales sont physiologiques. En plus, d’assurer le réalisme des solutions, notre contrainte articulaire tridimensionnelle n’a pas affecté le coût de calculs de l’optimisation. v) et vi) Les seize participants ont également réalisé des séries d’amplitudes articulaires passives et des exercices de rééducation passifs. La contrainte dans l’ensemble des muscles de la coiffe des rotateurs au cours de ces mouvements a été estimée à l’aide d’un modèle musculo-squelettique reproduisant différents types et tailles de déchirures. Des seuils de contrainte sécuritaires ont été utilisés pour distinguer les amplitudes de mouvements risquées ou non pour l’intégrité de la réparation chirurgicale. Une taille de déchirure plus grande ainsi que les déchirures affectant plusieurs muscles ont contribué à réduire l’espace de mobilité articulaire sécuritaire. Principalement les élévations gléno-humérales inférieures à 38° et supérieures à 65°, ou réalisées avec le bras maintenu en rotation interne engendrent des contraintes excessives pour la plupart des types et des tailles de blessure lors de mouvements d’abduction, de scaption ou de flexion. Cette thèse a développé une représentation innovante de la mobilité de l’épaule, qui tient compte des interactions entre les degrés de liberté. Grâce à cette représentation, l’évaluation clinique pourra être plus exhaustive et donc élargir les possibilités de diagnostiquer les troubles de l’épaule. La simulation de mouvement peut maintenant être plus réaliste. Finalement, nous avons montré l’importance de personnaliser la rééducation des patients en termes d’amplitude articulaire, puisque des exercices passifs de rééducation précoces peuvent contribuer à une re-déchirure à cause d’une contrainte trop importante qu’ils imposent aux tendons. / The shoulder is the most mobile but instable joint of the human body due to bony constraint scarcity and soft tissue function unlocking several degrees of freedom (DoF). Shoulder mobility is a factor of performance in some sports. But its instability leads to musculoskeletal impairments, the rotator cuff tear being the most debilitating disorder. Evaluation of the shoulder range of motion (RoM) is a common indicator of shoulder function but it is often limited to a few monoplanar measurements where each DoF varies independently. These values used in computer simulation models lead to non-physiological movements. The aim of this thesis was to develop tools for caracterizing tridimensional shoulder mobility. In this purpose it was mandatory to i) provide a method and its experimental approach to assess shoulder 3D (three-dimensional) RoM with DoF interactions; ii) propose a representation allowing 3D kinematical data interprestation; iii) present normalized shoulder amplitudes; iv) implement 3D RoM into computer simulation models to generate more realistic optimal sports technique; and v) predict safe 3D RoM and vi) safe rehabilitation exercises for patients after rotator cuff repair. i) Sixteen participants performed series of active arm movements with maximal amplitude with interactions between all the shoulder degrees-of-freedom. A motion analysis system combined with an upper limb kinematic model was used to estimate the 3D joint kinematics. ii) All 3D angular poses were included into a nonconvex hull representing the RoM space accounting for DOF interactions. The combination of elevation and rotation series is recommended to fully evaluate shoulder RoM. iii) A normalized 3D RoM space was defined by including 3D poses common to 50% of the participants into a hull of average volume. iv) This average hull, defining physiologic mobility, was used in a computer simulation model to optimize the technique of a release move in gymnastics. With commonly used monoplanar constraints of shoulder mobility, only 17% of the simulations led to a physiological shoulder kinematics, while our 3D RoM constraints systematically ensures realistic shoulder kinematics without extra computational cost. v) and vi) The 16 participants performed 3D shoulder range-of-motion and passive rehabilitation exercises. Stress in all rotator cuff tendons was predicted during each movement by means of a musculoskeletal model using simulations with different type and size of tears. Safety stress thresholds were used to discriminate safe from unsafe ranges-of-motion. Increased tear size and multiple tendons tear decreased safe range-of-motion. Mostly, glenohumeral elevations below 38°, above 65°, or performed with the arm held in internal rotation cause excessive stresses in most types and sizes of injury during abduction, scaption or flexion. This thesis established an innovative representation of the shoulder mobility, which accounts for DoF interactions. Clinical evaluation will be more accurate with a large potential to better diagnose shoulder disorders. Computer simulations are now more realistic. Finally, we showed the importance of personalized rehabilitation in terms of 3D RoM, since passive early rehabilitation exercises could contribute to re-tear due to excessive stress.
33

Développement d'indicateurs biomécaniques en manutention et leur application dans l'étude des différences entre les sexes lors de levers de charges en hauteur

Martinez, Romain 09 1900 (has links)
Les blessures musculo-squelettiques du membre supérieur représentent un problème de santé publique dans le secteur de la manutention. En plus d’affecter la qualité de vie du travailleur, ces lésions entraînent une perte de temps de travail et une augmentation des coûts de production. Alors que nous avons des évidences épidémiologiques que les femmes manutentionnaires sont plus nombreuses que les hommes à souffrir de douleurs à l’épaule, la littérature fait défaut d’indices biomécaniques qui expliquent l'origine de cette différence. L'objectif général de cette thèse était d'améliorer l'évaluation des techniques de manutention du membre supérieur, avec trois objectifs spécifiques : (1) développer des indices cinématiques, électromyographiques et musculo-squelettiques synthétiques pour évaluer et différencier des techniques de manutention du membre supérieur ; (2) développer un logiciel libre d'analyse biomécanique ; et (3) utiliser les indices et le logiciel développés pour décrire les différences biomécaniques entre des femmes et des hommes manutentionnaires. Nous avons récolté des données de cinématique, d'électromyographie et de force sur 30 femmes et 30 hommes réalisant une tâche de manutention qui consistait à déplacer une boîte de 6 et 12 kg entre la hauteur des hanches et la hauteur des yeux. À partir de ces données, nous avons développé des indicateurs synthétiques : un indicateur cinématique utile pour identifier des techniques de manutention problématiques et plus généralement les fonctions articulaires ; des indicateurs électromyographiques qui permettent d'estimer la quantité d'activation musculaire et la co-contraction musculaire ; et des indicateurs musculo-squelettiques qui permettent d'estimer les contraintes musculaires totales et les contraintes appliquées à l'articulation glénohumérale. Nous avons implémenté ces indicateurs avec pyomeca, notre logiciel libre d'analyse biomécanique. Mis à disposition de la communauté biomécanique, pyomeca supporte des tâches utiles dans le quotidien d'un chercheur biomécanique, mais également des routines biomécaniques plus avancées, axées sur la mécanique du corps rigide et le traitement de signal. Ce dernier se démarque des logiciels biomécaniques existants parce que c'est une solution libre, conviviale, spécialisée et sûre. Nous avons ensuite appliqué les indices synthétiques pour décrire les différences biomécaniques entre les femmes et les hommes participant à notre expérimentation. L'indicateur cinématique a montré que les femmes employaient une technique de manutention moins sécuritaire, avec une plus grande contribution glénohumérale, une faible contribution des membres inférieurs et une boite plus éloignée du tronc. Ces différences de technique se sont répercutées sur les indicateurs électromyographiques et musculo-squelettiques, avec des activations musculaires deux fois plus importantes comparativement aux hommes et une moindre stabilité de l'articulation glénohumérale. Ces différences pourraient contribuer à expliquer la prévalence de blessure du membre supérieur plus élevée chez les femmes manutentionnaires. Cette thèse a donc permis de développer des indicateurs synthétiques et un logiciel libre d'analyse biomécanique qui pourraient permettre aux ergonomes d'évaluer l'exposition aux risques de blessures du membre supérieur pendant une tâche de travail dynamique. Appliqués à une population spécifique, ces indicateurs suggèrent qu'il est crucial d'accorder une attention particulière au sexe pendant l'évaluation d'une tâche de travail au-dessus des épaules. / Work-related upper limb musculoskeletal disorders represent a public health challenge in the material handling industry. In addition to affecting the worker's quality of life, these injuries result in lost work time and increased production costs. While we have epidemiological evidence that more female material handlers suffer from shoulder pain than men, the literature is lacking biomechanical indicators that explain the origin of this difference. The general objective of this thesis was to improve the evaluation of upper limb handling techniques, with three specific objectives~: (1) to develop synthetic kinematic, electromyographic and musculoskeletal indicators to evaluate and differentiate upper limb handling techniques~; (2) to develop an open source biomechanical analysis software~; and (3) to use the developed indicators and software to describe the biomechanical differences between female and male workers. We collected kinematics, electromyography and force data on 30 women and 30 men performing a handling task that consisted in lifting a 6 and 12~kg box from hip to eye level. From these data, we developed synthetic indicators~: a kinematic indicator useful to identify poor handling techniques and more generally joint functions~; two electromyographic indicators to quantify the amount of muscle activation and muscle co-contraction~; and two musculoskeletal indicators to estimate total muscle stress and stress applied to the glenohumeral joint. We have implemented these indicators with pyomeca, our open-source biomechanical analysis software. Available to the biomechanical community, pyomeca provide basic operations useful in the daily workflow of a biomechanical researcher, but also more advanced biomechanical routines geared towards rigid body mechanics and signal processing. pyomeca stands from existing biomechanical software because it is an open-source, user-friendly, specialized and secure solution. We then applied our synthetic indicators to describe the biomechanical differences between the women and men participating in our experiment. The kinematic indicator showed that women used a poor handling technique, with a higher glenohumeral contribution, a low contribution from the lower limbs and a box further away from the trunk. These differences in technique affected the electromyographic and musculoskeletal indicators, with twice as much muscle activation compared to men and less glenohumeral stability. These results may contribute to the sex difference in the prevalence of upper limb musculoskeletal disorders. This thesis has enabled the development of biomechanical indicators and an open-source software that could allow ergonomists to assess the upper limb exposure during a dynamic lifting task. Applied to a specific population, these indicators argue for a careful consideration of sex during ergonomics intervention, particularly during overhead work.

Page generated in 0.0821 seconds