• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Measurement of neutron flux spectra in a Tungsten Benchmark by neutron foil activation method / Messung der Neutronenflussspektren in einem Wolfram-Benchmark mit der Multifolien-Neutronenaktivierungstechnik

Negoita, Cezar Ciprian 16 August 2004 (has links) (PDF)
The nuclear design of fusion devices such as ITER (International Thermonuclear Experimental Reactor), which is an experimental fusion reactor based on the "tokamak" concept, rely on the results of neutron physical calculations. These depend on the knowledge of the neutron and photon flux spectra which is particularly important because it permits to anticipate the possible answers of the whole structure to phenomena such as nuclear heating, tritium breeding, atomic displacements, radiation shielding, power generation and material activation. The flux spectra can be calculated with transport codes, but validating measurements are also required. An important constituent of structural materials and divertor areas of fusion reactors is tungsten. This thesis deals with the measurement of the neutron fluence and neutron energy spectrum in a tungsten assembly by means of multiple foil neutron activation technique. In order to check and qualify the experimental tools and the codes to be used in the tungsten benchmark experiment, test measurements in the D-T and D-D neutron fields of the neutron generator at Technische Universität Dresden were performed. The characteristics of the D-D and D-T reactions, used to produce monoenergetic neutrons, together with the selection of activation reactions suitable for fusion applications and details of the activation measurements are presented. Corrections related to the neutron irradiation process and those to the sample counting process are discussed, too. The neutron fluence and its energy distribution in a tungsten benchmark, irradiated at the Frascati Neutron Generator with 14 MeV neutrons produced by the T(d, n)4He reaction, are then derived from the measurements of the neutron induced γ-ray activity in the foils using the STAYNL unfolding code, based on the linear least-square-errors method, together with the IRDF-90.2 (International Reactor Dosimetry File) cross section library. The differences between the neutron flux spectra measured by means of neutron foil activation and the neutron flux spectra obtained in the same assembly, making use of an NE213 liquid-scintillation spectrometer were studied. The comparison of measured neutron spectra with the spectra calculated with the MCNP-4B (Monte Carlo neutron and photon transport) code, which allows a crucial test of the evaluated nuclear data used in fusion reactor design, is discussed, too. In conclusion, this thesis shows the applicability of the neutron foil activation technique for the measurement of neutron flux spectra inside a thick tungsten assembly irradiated with 14 MeV from a D-T generator. / Die Konstruktion von Fusionsreaktoren wie ITER (International Thermonuclear Experimental Reactor), der ein experimenteller Fusionsreaktor ist und auf dem "Tokamak"-Konzept beruht, basiert unter neutronenphysikalischen Gesichtspunkten auf den Ergebnissen von umfangreichen Simulationsrechnungen. Diese setzen die Kenntnis der Spektren des Neutronen- und Photonenflusses voraus die besonders wichtig ist, weil sie, die möglichen Antworten der ganzen Struktur auf physikalische Prozesse vorauszuberechnen erlaubt wie z.B.: Heizen durch nukleare Prozesse, Tritium-Brüten, Atomverschiebung, Abschirmung von Strahlung, Leistungserzeugung und Materialaktivierung. Die Flußspektren können mittels Transportcodes berechnet werden, aber es werden auch Messungen zu ihrer Bestätigung benötigt. Ein wichtiger Bestandteil des Strukturmaterials und der Divertor-Flächen der Fusionsreaktoren ist Wolfram. Diese Dissertation behandelt die Messungen der Neutronspektren und ?fluenz in einer Wolfram-Anordnung mittels der Multifolien-Neutronenaktivierungstechnik. Um die anzuwendenden experimentellen Geräte und die Codes, die im Wolfram-Benchmark-Experiment eingesetzt werden, zu überprüfen und zu bestimmen, wurden Testmessungen in den D-T und D-D Neutronenfeldern des Neutronengenerator der Technischen Universität Dresden durchgeführt. Die Eigenschaften der D-T und D-D Reaktionen, die für die Erzeugung von monoenergetischen Neutronen verwendet werden, sowie die Auswahl der Aktivierungsreaktionen, die für Fusionsanwendungen geeignet sind und die Aktivierungsmessung werden detailliert vorgestellt. Korrekturen, die sich auf den Neutronen-Bestrahlungsprozess und auf den Probenzählungsprozess beziehen, werden ebenfalls besprochen. Die Neutronenfluenz und ihre Energieverteilung in einem Wolfram-Benchmark, bestrahlt am Frascati Neutronen Generator mit 14 MeV-Neutronen aus der T(d, n)4He Reaktion, werden aus den Messungen der γ-Strahlenaktivität, die von Neutronen in den Folien induziert ist, durch den STAYNL Entfaltungscode, der auf der Methode der kleinsten Fehlerquadrate basiert, zusammen mit der IRDF-90.2 Wirkungsquerschnitt-Bibliothek abgeleitet. Die Unterschiede zwischen den Neutronenflußspektren, die mit Hilfe der Multifolien-Neutronenaktivierung ermittelt wurden, und den Neutronenflußspektren, gemessen im selben Aufbau mit einem NE-213 Flüssigszintillator, wurden untersucht. Die gemessenen Neutronenspektren werden den aus MCNP-4B Rechnungen (Monte Carlo neutron and photon transport) ermittelten Spektren gegenüber gestellt. Der Vergleich stellt einen wichtigen Test der evaluierten Kerndaten für Fusionsreaktorkonzepte dar. Zusammenfassend zeigt diese Arbeit die Anwendbarkeit der Multifolien-Neutronenaktivierungstechnik bei Messungen der Neutronenflussspektren innerhalb eines massiven Wolframblocks bei Bestrahlung mit schnellen Neutronen aus D-T Generatoren.
2

Measurement of neutron flux spectra in a Tungsten Benchmark by neutron foil activation method

Negoita, Cezar Ciprian 19 August 2004 (has links)
The nuclear design of fusion devices such as ITER (International Thermonuclear Experimental Reactor), which is an experimental fusion reactor based on the "tokamak" concept, rely on the results of neutron physical calculations. These depend on the knowledge of the neutron and photon flux spectra which is particularly important because it permits to anticipate the possible answers of the whole structure to phenomena such as nuclear heating, tritium breeding, atomic displacements, radiation shielding, power generation and material activation. The flux spectra can be calculated with transport codes, but validating measurements are also required. An important constituent of structural materials and divertor areas of fusion reactors is tungsten. This thesis deals with the measurement of the neutron fluence and neutron energy spectrum in a tungsten assembly by means of multiple foil neutron activation technique. In order to check and qualify the experimental tools and the codes to be used in the tungsten benchmark experiment, test measurements in the D-T and D-D neutron fields of the neutron generator at Technische Universität Dresden were performed. The characteristics of the D-D and D-T reactions, used to produce monoenergetic neutrons, together with the selection of activation reactions suitable for fusion applications and details of the activation measurements are presented. Corrections related to the neutron irradiation process and those to the sample counting process are discussed, too. The neutron fluence and its energy distribution in a tungsten benchmark, irradiated at the Frascati Neutron Generator with 14 MeV neutrons produced by the T(d, n)4He reaction, are then derived from the measurements of the neutron induced γ-ray activity in the foils using the STAYNL unfolding code, based on the linear least-square-errors method, together with the IRDF-90.2 (International Reactor Dosimetry File) cross section library. The differences between the neutron flux spectra measured by means of neutron foil activation and the neutron flux spectra obtained in the same assembly, making use of an NE213 liquid-scintillation spectrometer were studied. The comparison of measured neutron spectra with the spectra calculated with the MCNP-4B (Monte Carlo neutron and photon transport) code, which allows a crucial test of the evaluated nuclear data used in fusion reactor design, is discussed, too. In conclusion, this thesis shows the applicability of the neutron foil activation technique for the measurement of neutron flux spectra inside a thick tungsten assembly irradiated with 14 MeV from a D-T generator. / Die Konstruktion von Fusionsreaktoren wie ITER (International Thermonuclear Experimental Reactor), der ein experimenteller Fusionsreaktor ist und auf dem "Tokamak"-Konzept beruht, basiert unter neutronenphysikalischen Gesichtspunkten auf den Ergebnissen von umfangreichen Simulationsrechnungen. Diese setzen die Kenntnis der Spektren des Neutronen- und Photonenflusses voraus die besonders wichtig ist, weil sie, die möglichen Antworten der ganzen Struktur auf physikalische Prozesse vorauszuberechnen erlaubt wie z.B.: Heizen durch nukleare Prozesse, Tritium-Brüten, Atomverschiebung, Abschirmung von Strahlung, Leistungserzeugung und Materialaktivierung. Die Flußspektren können mittels Transportcodes berechnet werden, aber es werden auch Messungen zu ihrer Bestätigung benötigt. Ein wichtiger Bestandteil des Strukturmaterials und der Divertor-Flächen der Fusionsreaktoren ist Wolfram. Diese Dissertation behandelt die Messungen der Neutronspektren und ?fluenz in einer Wolfram-Anordnung mittels der Multifolien-Neutronenaktivierungstechnik. Um die anzuwendenden experimentellen Geräte und die Codes, die im Wolfram-Benchmark-Experiment eingesetzt werden, zu überprüfen und zu bestimmen, wurden Testmessungen in den D-T und D-D Neutronenfeldern des Neutronengenerator der Technischen Universität Dresden durchgeführt. Die Eigenschaften der D-T und D-D Reaktionen, die für die Erzeugung von monoenergetischen Neutronen verwendet werden, sowie die Auswahl der Aktivierungsreaktionen, die für Fusionsanwendungen geeignet sind und die Aktivierungsmessung werden detailliert vorgestellt. Korrekturen, die sich auf den Neutronen-Bestrahlungsprozess und auf den Probenzählungsprozess beziehen, werden ebenfalls besprochen. Die Neutronenfluenz und ihre Energieverteilung in einem Wolfram-Benchmark, bestrahlt am Frascati Neutronen Generator mit 14 MeV-Neutronen aus der T(d, n)4He Reaktion, werden aus den Messungen der γ-Strahlenaktivität, die von Neutronen in den Folien induziert ist, durch den STAYNL Entfaltungscode, der auf der Methode der kleinsten Fehlerquadrate basiert, zusammen mit der IRDF-90.2 Wirkungsquerschnitt-Bibliothek abgeleitet. Die Unterschiede zwischen den Neutronenflußspektren, die mit Hilfe der Multifolien-Neutronenaktivierung ermittelt wurden, und den Neutronenflußspektren, gemessen im selben Aufbau mit einem NE-213 Flüssigszintillator, wurden untersucht. Die gemessenen Neutronenspektren werden den aus MCNP-4B Rechnungen (Monte Carlo neutron and photon transport) ermittelten Spektren gegenüber gestellt. Der Vergleich stellt einen wichtigen Test der evaluierten Kerndaten für Fusionsreaktorkonzepte dar. Zusammenfassend zeigt diese Arbeit die Anwendbarkeit der Multifolien-Neutronenaktivierungstechnik bei Messungen der Neutronenflussspektren innerhalb eines massiven Wolframblocks bei Bestrahlung mit schnellen Neutronen aus D-T Generatoren.

Page generated in 0.1558 seconds