• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1879
  • 978
  • 10
  • 10
  • 7
  • 6
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 2895
  • 2759
  • 611
  • 592
  • 557
  • 498
  • 498
  • 459
  • 415
  • 381
  • 379
  • 378
  • 339
  • 314
  • 301
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
471

Organic binder as a substitute for bentonite in ilmenite pelletization

Sunde, Marius January 2012 (has links)
TiZir Titanium & Iron produces high titania slag and high purity pig iron from ilmenite in Tyssedal. The ilmenite is pelletized before smelting. Bentonite is added to the ilmenite concentrate as a binder to give the pellets strength and durability. Bentonite consists mainly of silica and alumina, which are considered as impurities in the high titania slag production. The use of organic binder has therefore been suggested as a substitute for bentonite.This work has focused on developing knowledge on the pelletization process and investigating various organic binders.Two methods of agglomeration, pelletization and briquetting, have been used in this work. Three batches of pellets have been made using a laboratory scale pelletizing drum. Two organic binders, Peridur 300 and Peridur 330, have been tested and compared to pellets made with bentonite and without binder. Seven batches of briquettes have been made using a cylindrical mold and a piston. Three organic binders, Peridur 300, calcium lignosulfonate and a nano cellulose fibre have been tested and compared to briquettes made with bentonite and without binder. The characterization included drop number test (pellets only), compression strength and thermal treatment.Briquettes were employed because using pellets yielded large deviations in the results. These deviations were believed to stem from the varying geometry of the pellets and were substantially mitigated by the use of cylindrical briquettes. It was found that Peridur 300 is a potential alternative to bentonite. The findings from thermal treatment suggest that above 500 degrees celcius sintering takes over as the dominating binding mechanism. For green strength, increasing binder viscosity has a positive effect.
472

Temporal Opinion Mining

Bjørkelund, Eivind, Burnett, Thomas Hoberg January 2012 (has links)
This project explores the possibilities in detecting changes in opinion over time. For this purpose, different techniques and algorithms in opinion mining have been studied and used as a theoretic foundation when developing strategies towards detecting changes in opinions.Different approaches to a system that detects and visualises changes in opinions have been proposed. These approaches include using machine learning techniques like the naiveBayes algorithm and opinion mining techniques based on SentiWordNet. Additionally,feature extraction techniques and the impact of burst detection have been studied.During this project, experiments have been carried out in order to test some of the techniques and algorithms. A data set containing hotel reviews and a prototype have beenbuilt for this purpose, allowing easy support for testing and validation. Results found high accuracy in opinion mining with the lexicon SentiWordNet, and the prototype can detect hotel features and possible reasons for changes in opinion. It can also show "good" and "bad" geographical areas based on hotel reviews.For commercial use, the prototype can help analyse the massive amount of hotel informa-tion published each day by customers, and can help hotel managers analyse their products. It can also be used as a more advanced hotel search engine where users can find extra information in a map user interface.
473

Masteroppgave i vassdragsteknikk : Sammenlikning av små elvekraftverk og kraftverk med magasin / Master Thesis in Hydro Power

Lofthus, Sigrid Jacobsen January 2012 (has links)
Det siste tiåret har småkraftutbygginger økt kraftig. Små kraftverk har generelt blitt oppfattet som mindre kontroversielt enn større magasinkraftverk, men lite er gjort for å sammenligne disse to kraftverkstypene når det gjelder nytteverdi og miljøpåvirkning. Målet med denne rapporten var å gjøre en sammenligning av et større magasinkraftverk og flere små elvekraftverk med tanke på produksjon, økonomi, naturinngrep, miljøvirkning og samfunnsnytte. Videre var det ønskelig å gjøre en mer generell vurdering av små kraftverk og et større magasinkraftverk, med utgangspunkt i de analyserte kraftverkene. Studieområdet var Kvannevatn og Sagelva i Rana kommune, der det i dag står tre små elvekraftverk, Kvannevatn kraftverk, Sagelva I og Sagelva II. Minikraft AS, som er eier av disse elvekraftverkene, søkte tidligere om å få bygge et større magasinkraftverk. Sammenligningen tar utgangspunkt i dagens små elvekraftverk og et tenkt tilfelle med kun det planlagte magasinkraftverket. Analysen av magasinkraftverket ble basert på dataprogrammet nMAG2004 som er en simuleringsmodell for drift og kraftproduksjon i vannkraftsystemer. Simuleringene forutsetter informasjon om blant annet magasin, kraftstasjoner, energimarkedet, restriksjonsdata, operasjonsstrategi og hydrologiske data. De hydrologiske dataene for både magasinkraftverket og de små kraftverkene ble basert på en nærliggende målestasjon, Bredek.For å strukturere de ulike konsekvensene ved en planlagt magasinkraftutbygging, ble Samla plan-metoden benyttet. Den kategoriserer konsekvensene inn i primære virkninger, fysiske virkninger, det levende miljø og til slutt brukerinteressene. Metoden ga også et grunnlag for å fastsette en miljøbasert minstevannføring. Ved å bruke Samla plan-metoden ble fisk og den estetiske opplevelsen av elva vurdert til å være de viktigste verdiene i Sagelva for å sette et miljøbasert krav til minstevannføring. Disse verdiene ville mest sannsynlig ikke blitt ivaretatt ved den minstevannføringen som var planlagt basert på tradisjonelle beregninger til å være 0,035 m3/s om vinteren, og 0,135 m3/s om sommeren. Kravet til en miljøbasert minstevannføring ble satt ved hjelp av building block-metoden som baseres på at hvert definerte behov utgjør en building block i vannføringsregimet (Alfredsen, Harby, Linnansaari, & Ugedal, 2011).Resultatene fra denne masteroppgaven viser at magasinkraftverket har mulighet til å slippe en miljøbasert vannføring og fortsatt ivareta en lønnsom produksjon. Den miljøbaserte minstevannføringen for magasinkraftverket ble satt til 0,15 m3/s fra september til og med april, 0,5 m3/s i mai, 1,5 m3/s i juni og juli, og 0,5 m3/s i august. Denne minstevannføringen ville imidlertid ikke vært forenlig med god produksjon for de små elvekraftverkene. Magasinkraftverket kan også produsere kraft gjennom hele året på grunn av reguleringsmuligheten, noe de tre elvekraftverkene ikke har mulighet til. Det ble derfor konkludert med at magasinkraftverket har større samfunnsnytte enn de tre små kraftverkene med tanke på leveringssikkert. Basert på studiet av de tre elvekraftverkene og magasinkraftverket i Sagelva kan det videre konkluderes med at man ikke kan bevare viktige verdier i et vassdrag ved å sette et minstevannføringskrav gjennom et standardisert «skrivebords-studie». Siden hvert eneste vassdrag er unikt, er det rimelig å anta at disse verdiene må kartlegges og vurderes spesielt for hvert vassdrag, og at krav til minstevannføring bør settes spesielt ut i fra hvilke verdier som skal ivaretas.Ut ifra beregninger viste det seg at det opprinnelig planlagte magasinkraftverket ikke var optimalisert, da bare 2-3 meter av en reguleringshøyde på 10 meter ble utnyttet i et normalår. I tillegg ville flomtapet i et normalår være stort. Dette gjorde at sammenligningen av det planlagte magasinkraftverket og de små kraftverkene basert på produksjonen ville bli misvisende, ettersom magasinkraftverket ikke var optimalisert.På grunn av den dårlige utnyttelsen av magasinet som var planlagt opprinnelig, ble det utført en ny beregning av magasinkraftverket. Denne beregningen optimaliserer ikke magasinkraftverket fullstendig, men var ment til å gi en indikasjon på hvilket potensiale det har. Resultatene fra denne beregningen viste at magasinkraftverket har potensialet til å produsere større mengder kraft enn de tre små elvekraftverkene, men at en optimalisering av magasinkraftverket er nødvendig.
474

Simulation of Unstable Two-phase Flows in Long Risers

Akselsen, Andreas Holm January 2012 (has links)
The principles of the object oriented slug tracking schemes at EPT (Department of Energy and Process Engineering, NTNU) have been developed and discussed in some detail.Simple bench-mark testing revealed that the LASSI code suffers form a pipe inclination-dependant lack of mass conservation, the cause of which is presently unidentified.Comparing simplified and non-simplified SLUGGIT simulations with experimental data published by Taitel <i>et al.</i> mostly indicate a reasonable correspondence, though the precision is somewhat imprecise. In particular, obtaining stable riser flow (free of significant pressure oscillations) at low liquid flow rates was not managed without excessive gas rates.This is possibly a consequence of the method's intrinsic slug flow approximation to dispersed regimes, but further investigation showed that the methods stability response altered with recent code versions in which alterations to management procedures was identified as the main differences, indicating that the SLUGGIT method's riser stability properties are quite sensitive to intuition-based section management routines. Further developing the models to better accommodate vertical flow regimes is advised.Supplementary testing was afforded through the development of a steady-state unit-cell type model for phase fractions in the riser. Excellent accordance with simulation data was found, confirming that the SLUGGIT model is capable of reproducing stable, expanding bubble flow. Coarse resolution served to disturb this process as bubbles becomes longer and are affected by riser entrance and exit effects. It was also found that pressure oscillations caused by such entrance and exit effects display the typical characteristics of terrain slugging and may be mistaken as such.With basis in the P50 Girassol pipeline, a systematic investigation into operational instability phenomena has been carried out using the available boundary conditions. Instabilities rooted in gas accumulation in jumpers, possibly also influenced by the U-bend, were found when studying the fixed pressure open inlet condition. The character of these instabilities were of a frequency and intermittency uncongenial to the field data. Most instability phenomena captured in these simulations were sensitive to changes in geometry, inlet condition and management parameters. Severe slugging was initially found to dominate the flow picture with a fixed flow closed inlet condition. Also this type of operational instability had too high a frequency to be a match with the field data. Nor does the well-know `shark fin' pressure profile of the terrain slugging liquid build-up and blow-out precesses match the sinusoidal character of the field data.It was recently found that the supplied field data needed adjustment for phase transition at the inlet state, amounting to a considerable reduction in gas flow. This produced predictions of more stable production compatible with those generated by external participant, though significant pressure fluctuations were still observed. These fluctuations were found to originate from slugging in the U-bend and entrance effects as large Taylor bubbles formed through coalescence and penetrated into the riser.This latter cause is believed to be a feature of the limited, non-dispersed flow objects available in the EPT models.A production index type boundary condition was implemented to better accommodate the well production response. Even so, the conditions under which the Girassol field instability data was recorded could not be recreated satisfactorily without gas lift and PVT support implemented. Simulations including the productivity index inlet indicated, for the most part, that without the presence of a gas lift system, the pipeline is likely to come to a complete stand-still; unless the liquid in riser and well are strongly aerated at all times, the well head will not be sufficient to overcome the total system liquid column weight.
475

Electro-oxidation of ethanol at Pt electrodes with the use of a Dynamic Electrochemical Impedance Spectroscopy (DEIS) technique

Døssland, Line Teigen January 2012 (has links)
Electro-oxidation of ethanol on smooth platinum surfaces was studied in thetemperature range 21C to 140C for 0.2 M ethanol in 0.5 M sulphuric acid.This was done by use of cyclic voltammetry and electrochemical impedancespectroscopy. In addition cyclic voltammetry with different ethanol concentrationsfrom 0.1 M to 1 M, in 0.5 M sulphuric acid was done at room temperature.Cyclic voltammetry with different ethanol concentrations showed a shift to morepositive potentials for the first oxidation peak in positive going scan as the ethanolconcentration increased. A shift to more positive potentials was also observed forthe oxidation peak in the negative scan as the concentration increased from 0.1M to 1 M. This indicates that the optimum surface condition is reached at higherpotentials for higher ethanol concentrations. This can be because ethanol andadsorbed ethanol derivatives take up more active sites at the surface, thus leavingless active sites available for adsorbed water derivatives which is necessary for theoxidation of ethanol to acetic acid and CO2.Cyclic voltammetry was done for increasing temperatures from 21C up to 140Cfor 0.2 M ethanol in 0.5 M sulphuric acid. These results showed an increasein oxidation current for all oxidation peaks as the temperature increased. Adecrease in peak potential for the first oxidation peak was observed for increasingtemperatures. This indicates that the optimum surface condition for ethanoloxidation is reached at lower potentials at higher temperatures. There was alsoseen an decrease in the apparent onset potential of the first oxidation peak as thetemperature increases. These effects can come from increased thermal activity forwater adsorption at higher temperatures. The peak potential for the oxidationpeak in negative going scan increased with increasing temperatures. This cancome from an easier reduction of platinum oxide at higher temperatures.Dynamic electrochemical impedance spectroscopy measurements was done atdifferent temperatures from 21C up to 140C for 0.2 M ethanol in 0.5 Msulphuric acid solution. The results from the measurements at 60C was fittedto electrochemical equivalent circuits. This gave indications of one kineticallysignificant surface adsorbed species in most potential regions with a notableoxidation current. This in combination with literature suggesting that acetic acidand acetaldehyde is the major products from ethanol electro-oxidation suggestthat the adsorbed intermediate is something other than CO(ads). Results fromthis work together with existing literature on ethanol oxidation was used to givea suggested simplified reaction mechanism for ethanol electro-oxidation.
476

Livssyklusbetraktninger for levedyktig oppgradering av kontorbygg / Life Cycle Considerations for Sustainable Upgrading of Office Buildings

Wood, Oda Caroline January 2012 (has links)
Denne oppgaven omhandler vurderinger av levedyktighet, herunder betraktninger av konsekvenser for miljø og økonomi over tid. Det er gjennomført beregninger av livssykluskostnader, LCC, i henhold til NS 3454. I tillegg er det gjort en livsløpsvurdering (LCA) ved hjelp av klimagassregnskap.no. Dette knyttes opp mot en tenkt oppgradering av en kontorblokk i Sandvika til plusshusnivå. Tre ulike konsepter for oppgradering av kontorblokken ble vurdert, herunder to plusshuskonsept og en standard oppgradering etter gjeldende byggteknisk forskrift. Alle konseptene innebærer utskifting av fasaden, økte isolasjonsmengder i yttervegg og nytt ventilasjonsanlegg. Utover dette varierer konseptenes omfang. Plusshuskonseptene involverer installasjon av varmepumpe og solcellepanel på tak. Ved beregningene benyttes en analyseperiode på 25 år, og oppgraderingen betraktes som en av flere mindre sykluser i løpet av bygningens totale livsløp. Beregningene resulterte i kun små forskjeller mellom konseptenes analyseperiodekostnad. Det totale klimagassutslippet fra plusshuskonseptene var langt mindre enn ved standard oppgradering. Generelt peker energi- og materialbruk seg ut som de mest bidragsytende prosessene. Gjennomførte sensitivitetsanalyser viser at konseptenes relative prestasjoner forblir uendret selv ved relativt store variasjon i de antatte inputparameterne. Resultatene ble knyttet opp i et bærekraftig perspektiv for å kunne vurdere levedyktigheten av de ulike konseptene. På bakgrunn av dette kan det konkluderes med at plusshus i dette tilfellet er et mer levedyktig alternativ enn standard oppgradering. Dette begrunnes med at de i større grad møter fremtidige krav, samtidig som de minimerer de miljømessige og økonomiske konsekvensene som følge av oppgraderingen.
477

Validation of Wet Gas Surge Phenomena

Sørvik, Lars Andreas Øvrum January 2012 (has links)
AbstractIn order to utilize the fossil resources on the Norwegian continental shelf, technology and expertise have proven to be of great importance and hence, essential for further exploration and development of new resources. A key element in this matter is the subsea wet gas compression technology which enables the transport of well stream directly to a land based treatment system, or more remote processing facilities offshore. Compression of gas at the seabed is a significant technology advance no one has previously made. The technology of subsea gas compression is one of the most important measures to deliver increased volumes from existing gas fields as well as developing resources in more remote and vulnerable areas.Due to the need of expertise and development of subsea installations, in order to meet the demand for fossil fuels and be competitive in a constantly increasing market, the Norwegian University of Science and Technology (NTNU) has built an experimental rig to test a wet gas compressor. The rig is unique and important to analyze the basic mechanisms and occurrence of instabilities related to wet gas compression. Both the literature review and the experimental work presented here are performed in order to visualize and document instabilities related to the phenomena surge and stall. Experimental data in this master thesis are obtained from a one- stage wet gas centrifugal compressor with an axial direct inlet. The stage involves a shrouded impeller, a vaneless diffuser and a volute. The compressor is a part of an open loop facility that is located at NTNU in Trondheim. The test rig is designed to operate with different amounts of liquid in the gas with gas volume fractions (GVF) and gas mass fractions (GMF) down to correspondingly 0.95 and 0.5. Applications in LabView were made and designed to analyze the raw data from the pressure sensors and pitot tubes in order to post-process and represent the data in a graphical manner. Log files from a total of seven scientific experiments with dry- and wet gas were documented and analyzed to identify the impeller outlet angle and achieving a more precise identification of wet gas surge initiation and instability precursor. The steady state flow angle experiments revealed a stringent increase in flow angle with decreasing volume flow, for both the dry gas test of 10000 and 9000 rpm, with maximum corresponding flow angles of 81.5 and 86 degrees. A sudden rise in flow angle gradient was found to occur at a volume flow of 0.95 m3/s and 0.8 m3/s for 10000 rpm and 9000 rpm, respectively, due to the volute causing a shift change from deceleration to acceleration performance, at the respective volume flows. Flow angle measurements of dry gas were further validated and compared with Matlab and CFD simulation revealing coincident trends. The performed wet gas tests were associated with a greater uncertainty than dry gas, due to the influence of liquid. However, the wet gas curves showed distinct trends with lower discharge angles across the spectrum compared to the case for dry gas measurements.The transient surge identification test was conducted on 7500 rpm with alternating GMF in the range from 0.6 to 0.42. The pressure characteristic revealed the first sign of intermittent behavior at a volume flow of 0.26 m3/s prevailing sudden stringent static pressure fluctuations. The corresponding frequency spectrum for dynamic pressure sensors shows that the critical disturbance occurs, and is enhanced at low frequencies causing the initiation of surge at a volume flow of 0.27 m3/s. A pitot tube set-up for identification of surge onset was evaluated and compared to the measurements conducted by a static pressure-, a differential pressure- and a high responsive dynamic pressure sensor. The detection tube indicated a possible precursor to surge by prevailing change and high fluctuations in the stagnation pressure.Observation through the impeller inlet showed that an annular backflow ring was formed with decreasing volume flow. The first observation of the ring shape was done for a volume flow of 0.3 m3/s, followed by larger developments and a chaotic flow path with complete backflow for volume flow lower than 0.25 m3/s.
478

Nytteverdien av å etablere pumpe i et eksisterende vannkraftsystem / Benfit of implementing a pump in an existing hydropower system

Longva, Birgit January 2012 (has links)
Hovedfokus for oppgaven er å analysere nytten av en pumpe som et tillegg til kraftverket som ble vurdert i prosjektoppgaven ”Alternative tekniske løsninger for utbygging av lavtrykks kraftverk”. Kraftverket er plassert ved overføringstunnelen mellom hovedmagasinet og inntaksmagasinet til Tyin kraftverk. Prosjektoppgaven anbefalte å installere en Kaplan-turbin med kapasitet på ca. 9,5 MW og 35 m3/s i kraftverket. Dette er derfor grunnlaget for denne oppgaven.Hovedbegrunnelsen for en pumpe i systemet er at mye av tilsiget går direkte i inntaks-magasinet (Torolmen), som har relativt liten magasineringskapasitet. En må derfor noen ganger kjøre Tyin kraftverk selv om prisene er ugunstige og en heller skulle ønske å magasinere vannet. Ved å pumpe vannet fra for eksempel deler av vårflommen rundt 30 meter fra Torolmen og opp i det store magasinet i Tyinsjøen, kan en unngå produksjon i Tyin kraftverk til de mest ugunstige prisene. Kostnadene til investering i og drift av pumpa veies opp mot verdiøkningen som oppstår når dette vannet kjøres både gjennom Torolmen kraftverk og Tyin kraftverk etter at prisene har økt. Verdiøkningen gjelder hovedsaklig for produksjonen i Tyin kraftverk siden fallhøyden her er over 30 ganger så stor som pumpehøyden.Fem forskjellige pumpestørrelser er vurdert, og brukt i simuleringer av mengde pumpet vann og inntekt fra prisdifferansene i årene 2006 til 2011. Det er også gjort overslagsberegninger på hvilken prisdifferanse som er nødvendig for å kunne betale ned kapitalkostnaden for pumpa med ulike mengder pumpet vann. Resultatene sannsynliggjør lønnsomheten for pumpa. Pumpa gir økt fleksibilitet for hele systemet til en forholdsvis liten kostnad. Den prisdifferansen som skal til for å tjene inn pumpa er liten. I et marked som periodevis vil ha stort overskudd med stor sannsynlighet for kortere perioder med priskollaps, kan en pumpe som tar unna vannet være meget lønnsom. Stabiliteten til kraftverket er også vurdert. For å unngå for stor treghet i systemet og store trykkstøt som kan skade anlegget er en nødt til å ha en svingesjakt i systemet. Denne bør ha et vannspeilareal på minst 45 m2 for å unngå ustabile U-rørssvingninger mellom sjakt og magasin. Ved avslag etter pådrag får en også mye vann som må tas vare på. For å unngå overløp, må en finne en måte å ta unna dette vannet på, for eksempel øke tverrsnittet av sjakten ytterligere. Trykkøkningen foran turbinen blir på over 30 prosent, selv med et vannspeilareal i sjakten på 70 m2. Det trengs derfor en ventil eller luke som åpner seg ved brått avslag for å unngå dette. Tidskonstantene for vannveien gir en indikasjon på at systemet blir tungregulert og tregt, og et kraftverk ved Torolmen bør kjøres på et sterkt nett. Det vil mest sannsynlig si at kraftverket må kjøres samtidig med Tyin kraftverk. For å minske belastningen på nettet og sikre at pumpa ikke får fullt moment så raskt at det skader akslingen og motoren, kan en installere en soft-starter eller pumpe med turtallsregulering.
479

Characterization and recovery of rare earth elements from electronic scrap

Bristøl, Lene Marie Lysgaard January 2012 (has links)
The rare earth elements are a group of 17 elements consisting of the lantahnide series, scandium and yttrium. The application with the largest rare earth consumption is the permanent rare earth magnets. The neodymium-iron-boron magnets are the strongest permanent magnetic material known and are widely used. There is a concern that there will be a shortage in Nd-Fe-B magnets in short time. This has lead to an increased interest in the recycling of the rare earth magnets in the world.This project gives a very brief introduction to the Nd-Fe-B magnets, their uses and recycling. Two types of experiments that aims at recovery of neodymium from Nd-Fe-B magnets have been performed; extraction of neodymium by the use of molten silver and extraction of neodymium by direct oxidation. In the liquid silver experiments, extraction was obtained, but the analysis gave equivocal results. In the direct oxidation experiment, the separation of an iron phase and a neodymium oxide phase failed, and the experiment was not seen as successful.Magnetic waste from WEEE Recycling was also performed, and it turned out to contain small amounts of rare earth elements.
480

Romventilasjon for komfortkjøling / Room Air Distribution for Comfort Cooling

Rognes, Eskild Endal January 2012 (has links)
SammendragNye byggeforskrifter og krav til energimerking har bidratt til et økt fokus på energibruk i bygninger. Spesielt gjelder dette energibruk til kjøling i bygninger. Samtidig har de nye forskriftene gjort det mindre fordelaktig å benytte lokal mekanisk kjøling. Dette gjør det interessant å se på om kjøling kun med ventilasjonsluft kan være et alternativ, og i så fall hvilke ventilasjonsprinsipp som egner seg best for dette.Det er i denne oppgaven, med bruk av forsøk og simuleringer, sett på hvilket av de toventilasjonsprinsippene fortrengningsventilasjon og omrøringsventilasjon, som best egner seg til klimatisering av et vanlig kontor i et yrkesbygg i en sommersituasjon. Oppgaven er en videreføring av prosjektoppgaven som var en teoristudie av samme problemstilling. Først ble det gjennomført forsøk med tre ulike tilluftsventiler: to fortrengningsventiler, og en omrøringsventil. Forsøket ble satt opp slik at det skulle ligne mest mulig på et vanlig kontor, og det ble gjennomført to forsøk på hver tilluftsventil. De to forsøkene hadde konstante forhold med unntak av tilluftstemperaturen som ble variert. Forsøkene ble utført ved Airson Engineering sitt prøvelaboratorium i Ängelholm.Resultatene viste at alle tilluftsventilene oppnådde tilfredsstillende termiske forhold, men med klare forskjeller seg imellom. Begge fortrengningsventilene oppnådde en lavere lufttemperatur i oppholdssonen(for sittende personer) enn omrøringsventilen.Deretter ble det benyttet et simuleringsprogram, IDA ICE, for å beregne de termiskeforholdene og for å teste programmet opp mot forsøkene.Resultatene viste at for forsøkene med fortrengningsventilasjon var beregningene gode i den nedre del av rommet, mens for øvre del av rommet og avtrekket avviker simuleringene og de målte verdiene.For forsøkene med omrøringsventilasjon avvek simuleringene noe, ca. 1-2 °C, fra de målte verdiene.For alle forsøkene er det imidlertid en relativt god korrelasjon mellom de simulerte og de målte verdiene innenfor oppholdssonen for sittende personer(opp til 1,1m), da avvikene her er ca. < 1 °C. For øvre del av rommet ble det ikke gjort noen målinger med unntak av en i avtrekket, og her var avviket mellom simuleringene og de målte verdiene større, ca. < 3 °C. Det må imidlertid nevnes at det faktiske varmetapet fra forsøksrommet er betydelig større enn det simulerte, og dette skyldes mest sannsynlig skjulte kuldebroer og lignende som ikke blir fanget opp av simuleringsprogrammet.Resultatene viser at fortrengningsventilasjon oppnår en lavere temperatur i oppholdssonen for sittende personer enn omrøringsventilasjon. De målte verdiene for forsøkene med fortrengningsventilasjon ligger 1-1,5 °C under tilsvarende forsøk med omrøringsventilasjon, noe som er litt mindre enn praktiske erfaringer, men fremdeles utslagsgivende for energibruken til kjøling.Dette betyr at fortrengningsventilasjon vil kreve mindre kjøleenergi ennomrøringsventilasjon ved samme krav til termisk komfort.En enkel analyse av energibruken til kjøling viste at det kan oppnås store energibesparelser ved å heve tilluftstemperaturen bare med 1-2 °C.Fortrengningsventilasjon gir altså muligheten for å heve tilluftstemperaturen og dermedredusere energibruken til kjøling av uteluften, samtidig som den termiske komfortenopprettholdes.

Page generated in 0.0241 seconds