1 |
Desenvolvimento e validação da microextração líquido-líquido dispersiva com líquido iônico para determinação de omeprazol em plasma humano por cromatografia líquida de alta eficiência / Development and validation of an ionic liquid dispersive liquid-liquid microextration method for determination of omeprazole in human plasma by high performance liquid chromatographyDias, Larissa Alves dos Reis 28 September 2018 (has links)
O OME é empregado no tratamento de curto e longo prazo em diferentes desordens gastrointestinais. É um inibidor da bomba de prótons, que atua seletivamente na enzima H+/K+ ATPase. É completamente metabolizado pelas enzimas do citocromo P450 gerando três metabólitos principais: HOME, OMES e OS. É utilizado no tratamento de refluxo gastroesofágico em pacientes que sofrem de obesidade e sobrepeso no período anterior e posterior à cirurgia bariátrica. Entretanto, a realização deste procedimento cirúrgico pode prejudicar a absorção de nutrientes e medicamentos. Assim, a determinação das concentrações plasmáticas do OME é de grande importância clínica para o ajuste de dose evitando-se o comprometimento do tratamento. Portanto, foram desenvolvidos e validados dois métodos para quantificação do OME e metabólitos em amostras de plasma: LLE, método padrão e OS-DLLME e avaliada a IL-DLLME como método alternativo de extração. O método padrão, LLE, foi desenvolvido para quantificação do OME e metabólitos em amostras de plasma por HPLC-UV. A análise foi feita em uma coluna cromatográfica Zorbax Eclipse XDB - C18 (25 cm x 4,6 mm, partículas de 5 ?m) (Agilent Technologies, Palo Alto, CA, EUA) e coluna de guarda Zorbax Eclipse XDB - C18 (12,5 mm x 4,6 mm, partículas de 5 ?m) e FM composta por ACN: água (30:70, v/v), na vazão de 1 mL/min, detecção em 302 nm. Nestas condições foi possível a separação do OME e metabólitos em menos de 20 minutos. O método apresentou-se linear no intervalo de concentração plasmática de 20- 1000 ng/mL (r>0,99). Os parâmetros de precisão, exatidão, efeito carry-over e estabilidade estão em conformidade com o guia de validação da ANVISA (2012). O método foi satisfatoriamente aplicado em amostras de plasma de 20 pacientes submetidos à cirurgia bariátrica, no período pré e pós-cirúrgico. Outros dois métodos foram avaliados utilizando a técnica de microextração em fase líquida (DLLME). O método de OS-DLLME foi desenvolvido e validado para quantificação do OME e metabólitos em amostras de plasma por LCMS/ MS. A análise foi realizada na mesma coluna cromatográfica descrita anteriormente com FM composta por ACN:tampão formiato de amônio 10 mM pH 8,5 (50:50, v/v) vazão de 0,4 mL/min. Foram monitorados os íons precursores do OME, HOME, OMES e PI. As amostras de plasma foram pré-tratadas com ISO e com sobrenadante foi desenvolvida a OS-DLLME. Os parâmetros da OS-DLLME (tipo e volume de solvente extrator e dispersor, pH, força iônica do meio, tempo de agitação, tempo de centrifugação, volume de diluição da amostra e volume de amostra) foram otimizados com o auxílio de um delineamento experimental Plackett Burmann seguido por um CCD. Ao final uma metodologia de superfície de resposta facilitou a determinação da condição ótima de extração utilizando a ferramenta desejabilidade (D) na qual as condições otimizadas foram: 400?L de plasma, 2,5 mL de solução tampão tetraborato de sódio 0,1 mM pH 9,5, 120 ?L de CHCl3, 500 ?L de ISO, 0% de NaCl, 5 minutos de centrifugação, sem agitação das amostras. Posteriormente, o método foi aplicado com sucesso para análise de amostras de plasma de 5 pacientes submetidos à cirurgia bariátrica, no período pré e pós-cirúrgico.A IL-DLLME foi avaliada como técnica de extração utilizando ILs como solventes extratores alternativos. A análise foi realizada na mesma coluna cromatográfica com fase móvel no modo eluição por gradiente composta por ACN:água: 0-10 min, 5:95; 10,0-15 min, 10:90; 15,01-40 min, 30:70, v/v, vazão de 1 mL/min e detecção em 302 nm. Foram avaliados três ILs comerciais e oito ILs sintetizados no laboratório (NPPNS). Foram avaliados os parâmetros da IL-DLLME: solvente dispersor, IL extrator, pH e composição da solução tampão. Também foi realizada a avaliação por RMN dos IL utilizados. Dentre os ILs comerciais foi selecionado o OMImPF6, e dentre os ILs sintetizados foi selecionado o C8PF6. Entretanto, não foi possível o desenvolvimento do método devido a escassa quantidade de IL comercial. Em relação aos ILs sintetizados foram observados problemas na síntese e purificação, como presença de interferentes que coeluiam juntamente com os analitos avaliados. Entretanto, apesar deste método não ter sido validado foi possível obter valores de recuperação, para ambos os IL selecionados, superiores a 40%. / OME is used in the short- and long-term treatment of different gastrointestinal disorders. It is a proton pump inhibitor, which selectively acts on the enzyme H + / K + ATPase. It is completely metabolized by the cytochrome P450 enzymes generating three main metabolites: HOME, OMES and OS. It is used in the treatment of gastroesophageal reflux in patients who are obese and overweight in the period before and after bariatric surgery. However, performing this surgical procedure may impair the absorption of nutrients and medications. Thus, the determination of plasma concentrations of OME is of great clinical importance for dose adjustment, avoiding compromised treatment. Thus, two methods were developed for the quantification of OME and metabolites in plasma samples: LLE, standard method and OS-DLLME and IL-DLLME as an alternative method of extraction. The standard method, LLE, was developed for quantification of OME and metabolites in plasma samples by HPLC-UV. The analysis was done on a Zorbax Eclipse XDB-C18 (25 cm x 4.6 mm, 5 ?m particles) (Agilent Technologies, Palo Alto, CA, USA) and Zorbax Eclipse XDB-C18 (12, 5 mm x 4.6 mm, 5 ?m particles) and mobile phase composed of ACN: water (30:70, v / v) at the flow rate of 1 mL / min, detection at 302 nm. Under these conditions it was possible to separate OME and metabolites in less than 20 minutes. The method was linear in the plasma concentration range of 20-1000 ng / mL (r> 0.99). The parameters of accuracy, accuracy, carry-over effect and stability are in accordance with ANVISA\'s validation guide (2012). The method was satisfactorily applied in plasma samples from 20 patients submitted to bariatric surgery in the pre- and post-surgery period. Two other methods were evaluated using the liquid phase microextraction technique (DLLME). The OS-DLLME method was developed and validated for quantification of OME and metabolites in plasma samples by LC-MS / MS. The analysis was performed in the same chromatographic column described above with mobile phase composed of ACN: 10 mM ammonium formate buffer pH 8.5 (50:50, v / v) flow rate of 0.4 mL / min. The precursor ions of OME, HOME, OMES and PI were monitored. Plasma samples were pre-treated with ISO and the supernatant was grown to OS-DLLME. The parameters of OS-DLLME (type and volume of solvent extractor and dispersant, pH, ionic strength of medium, agitation time, centrifugation time, sample dilution volume and sample volume) were optimized with the aid of an experimental design Plackett Burmann followed by a central composite outline. At the end, a response surface methodology facilitated the determination of the optimal extraction condition using the desirability tool (D) in which optimized conditions were: 400?L of plasma, 2.5 mL of buffer solution 0.1 mM sodium tetraborate pH 9,5, 120 ?L CHCl3, 500 ?l ISO, 0% NaCl, 5 minutes centrifugation, without sample shaking. Subsequently, the method was validated and successfully applied for analysis of plasma samples from 5 patients submitted to bariatric surgery in the pre and post-surgical period. IL-DLLME was evaluated as an extraction technique using ILs as alternative extractive solvents. The analysis was performed on the iv same mobile phase chromatographic column in the gradient elution mode composed of ACN: water: 0-10 min, 5:95; 10.0-15 min, 10:90; 15.01 - 40 min, 30:70, v/v, flow rate of 1 mL / min and detection at 302 nm. Three commercial ILs and eight ILs synthesized in the laboratory (NPPNS) were evaluated. The parameters of IL-DLLME were evaluated: dispersing solvent, IL extractor, pH and buffer composition. NMR evaluation of the ILs used was also performed. Among the commercial ILs, OMImPF6 was selected, and C8PF6 was selected among the ILs synthesized. However, the development of the method was not possible due to the small amount of commercial IL. Concerning ILs synthesized, problems were observed in the synthesis and purification, as presence of interfering factors that coeluted together with the analyzed analytes. Thus, although this method was not validated, it was possible to obtain recovery values, for both ILs selected, higher than 40%.
|
2 |
Avaliação da microextração líquido-líquido dispersiva para determinação do levetiracetam e da risperidona por técnicas cromatográficas acopladas a espectrometria de massas / Evaluation of the dispersive liquid liquid microextraction for the determination of levetiracetam and risperidone by chromatographic techniques coupled mass spectrometryAlcantara, Greyce Kelly Steinhorst 06 June 2016 (has links)
A microextração líquido-líquido dispersiva baseada no uso de solventes orgânicos (OS-DLLME) vem recebendo grande destaque devido a facilidade de operação, baixo custo, rapidez e um consumo mínimo de solventes. Previamente a OS-DLLME um pré-tratamento do plasma se faz necessário a fim de propiciar a formação de uma adequada fase sedimentada. O levetiracetam (LEV) é um dos fármacos mais prescritos para o tratamento de crises epilépticas parciais e com generalizações secundárias. Assim, foi desenvolvido e validado um método bioanalítico para a quantificação do LEV em amostras de plasma por cromatografia em fase gasosa acoplada à espectrometria de massas (GC/MS). O pré-tratamento das amostras de plasma empregou ultrafiltros Amicon® (poros com tamanho de 10 kDa) que formavam um permeado adequado para a realização da OS-DLLME. A adição de 130 ?L de clorofórmio (solvente extrator) e 400 ?L de isopropanol (solvente dispersor), sem alteração na força iônica e agitação da amostra, proporcionaram 33 % de recuperação do LEV nas amostras de plasma. Tal análise foi realizada usando uma coluna de sílica fundida recoberta com Rtx-5MS (30 m × 0,25 mm x 0,25 ?m) empregando uma rampa de aquecimento. O tempo total de corrida cromatográfica foi de 9 minutos. O método apresentou-se linear no intervalo de concentração de 2 - 80 ?g mL-1 (r >= 0,99), onde os resultados foram ponderados (peso =1/x). A validade da regressão foi confirmada aplicando o teste da falta de ajuste linear. O limite inferior de quantificação (LIQ) foi de 2 ?g mL-1. Os parâmetros de precisão, exatidão, efeito matriz, efeito carry-over e estabilidade demonstraram-se em conformidade com o European Medicines Agency. Outro método foi desenvolvido e validado para a quantificação da risperidona (RSP) e seu metabólito 9-hidroxi-risperidona (9-OH-RSP) em amostras de plasma. A RSP e 9-OH-RSP correspondem a \"fração ativa\" do medicamento responsável pela atividade anticonvulsivante. As amostras de plasma foram pré-tratadas com ácido tricloroacético (TCA 30 %). O sobrenadante límpido foi diluído com solução de NaCl (10 %) e ajustado para o valor de pH 12, no qual foi desenvolvido a OS-DLLME. Foi adicionado um volume de 500 ?L de acetona (solvente dispersor) e 80 ?L de clorobenzeno (solvente extrator). Após otimização da extração, foi alcançado 89 % e 42 % de recuperação da RSP e 9-OH-RSP, respectivamente. Para tais análises foi empregada a cromatografia líquida acoplada à espectrometria de massas sequencial com ionização por eletrospray (LC-MS/MS). Uma coluna Ascentis® C18 (10 cm x 4,6 mm x 2,7 ?m), fase móvel composta por tampão acetato de amônio e acetonitrila, em modo de eluição gradiente, vazão de 500 ?L min-1 e temperatura da coluna de 40 ºC foram empregados. O tempo total da corrida cromatográfica foi de 8 minutos. O método foi linear na faixa de concentração de 5 - 80 ng mL-1 (r >= 0,99), para ambos os analitos. O LIQ foi de 5 ng mL-1. Todos os demais parâmetros estavam em conformidade com a agência regulatória. Ambos os métodos foram aplicados com sucesso em amostras de plasma de paciente em tratamento com LEV ou RSP. Desta forma foi possível demonstrar aplicabilidade dos métodos bioanalíticos desenvolvidos e averiguar a concentração plasmática dos devidos fármacos no paciente / Dispersive liquid-liquid microextraction technique based on the use of organic solvents (OS-DLLME) has received highlighted due to the easily, rapidity, low cost and low consumption of organic solvent. Prior to OS-DLLME, plasma pretreatment is necessary to provide the formation of a suitable settled phase. Levetiracetam (LEV) is one of the most prescribed drugs for the treatment-refractory partial onset seizures with or without secondary generalization. So, it was developed and validated a bioanalytical method for the quantification of LEV in plasma samples by Gas Chromatography Mass Spectrometry (GC/MS). The pretreatment of the plasma samples employed tubes of ultrafiltration Amicon® (pore size 10 kDa) in order to form a suitable permeated to carry out the OS-DLLME. The addition of 130 ?L of chloroform (extraction solvent) and 400 ?L of isopropanol (disperser solvent), without ionic strength and agitation of samples, have reached 33 % of recovery of LEV from plasma samples. This analysis was carried out using a fused silica coated Rtx-5MS column (30 m × 0.25 mm × 0.25 ?m) and a heating ramp. The run time was 9 minutes. The method was linear in the concentration range of 2 - 80 ?g mL-1 (r >= 0.99) and the results were weighted (1/x). The linear regression was confirmed by applying the lack of fit test. The lower limit of quantitation (LLOQ) was 2 ?g mL-1. The precision, accuracy, matrix effect, carry-over and stability were in agreement with European Medicines Agency. Another method was developed and validated for the quantification of risperidone (RSP) and its 9-hydroxy-risperidone metabolite (9-OH-RSP) from plasma samples. The RSP and 9-OH-RSP constitutes the total active moiety responsible for the anticonvulsant activity. Plasma samples were pretreated with trichloroacetic acid (TCA 30%). The clear supernatant was diluted with NaCl solution (10%) and adjusted to pH 12, where was developed the OS-DLLME. It was added 500 ?L of acetone (dispersing solvent) and 80 ?L of chlorobenzene (extraction solvent). After the parameters optimization, the recovery was 89% and 42% for RSP and 9-OH-RSP, respectively. It was employed liquid chromatography-electrospray-tandem-mass spectrometry (LC/ MS/MS). Ascentis® C18 column (10 cm x 4.6 mm x 2.7 ?M), ammonium acetate buffer and acetonitrile as mobile phase in gradient elution mode, at flow rate 500 ?L min-1 and column temperature of 40 °C for this analysis. The run time was 8 minutes. The method was linear in the concentration range 5 - 80 ng mL-1 (r >= 0.99) for both analytes. The LLOQ was 5 ng mL-1. All other parameters were in agreement with the regulatory agency. Both methods have been successfully applied in plasma samples from patient that receive diary doses of LEV or RSP. In this way, it was possible to present the applicability of developed bioanalytical methods and the quantitation of plasmatic concentration of these studied drugs.
|
Page generated in 0.0197 seconds