• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação das tensões geradas nos componentes protéticos de próteses obturadoras maxilares classe I, II e IV de Aramany por meio de análise de elementos finitos / Evaluation of stress generated in maxillar obturators prosthesis of class I, II and IV of Aramany in Finite Element Analysis

Miyashita, Elcio Ricardo 20 March 2013 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves sequelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de próteses obturadoras maxilares Classe I, II e IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 4.0 foi utilizado para a geração da malha de elementos finitos no programa Ansys Workbench 14.0®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores das próteses obturadoras, para observação das tensões geradas sobre as próteses obturadoras. Os resultados são apresentados sob a forma de análise qualitativa, indicada pelo estudo de Tensão Máxima Principal para as estruturas acrílicas da prótese e estudo de Von Mises para as estruturas metálicas da prótese, e análise quantitativa, representada por valores em Mega Pascal (MPa). Tanto nos carregamentos posteriores como nos carregamentos anteriores, foram observadas dissipações de cargas significativas localizadas na placa palatina próxima a ressecção e na junção do metal com o acrílico, sendo os maiores valores alcançados na placa de retenção metálica para retenção do acrílico localizada posteriormente na condição de carregamento posterior em ordem crescente na Classe II de Aramany com 149,17 MPa, Classe I de Aramany com 344,08 MPa e Classe IV de Aramany alcançando valor de 390,25 MPa. No acrílico da prótese obturadora, no caso de Classe I de Aramany em carregamento posterior, foi observada uma concentração de tensão principal na região correspondente ao limite lateral e anterior da junção da placa de retenção e do acrílico no valor de 19,796 MPa de tração. Na Classe IV de Aramany em carregamento posterior, foi observada uma concentração de tensão na região posterior da junção da placa de retenção e do acrílico no valor de 18,33 MPa. Na Classe II de Aramany, em carregamento posterior foi observada uma concentração de tensão na região anterior próxima ao limite da ressecção anterior no valor de 25,45 MPa de tração. Concluiu-se que os valores quantitativos alcançados neste estudo parecem não apresentar riscos de fratura sobre a armação metálica de liga de CrCo, porem podem apresentar riscos de falha na retenção metal/acrílico da prótese obturadora maxilar. A configuração de placa de recobrimento palatino proporciona uma melhor distribuição das tensões ao longo de sua superfície. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, determine the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class I,II andIV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 4.0 and then it was used to develop the finite element mesh in the software Ansys Workbench 14.0 ®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum stress and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that in the posterior loadings as in the anterior loadings were observed charge dissipation plate located in significant palate resection and near the junction of the metal with the acrylic and the highest values obtained in the metal retaining plate for retaining acrylic located further provided that subsequently loaded in ascending order in Class II Aramany with 149.17 MPa, Aramany with Class I and Class IV 344.08 MPa Aramany reaching value of 390.25 MPa. In acrylic prosthesis obturator in the case of Class I Aramany in subsequent loading, was observed a stress concentration in the region corresponding to the limit lateral and anterior junction of the retaining plate and the value of acrylic 19.796 MPa. Class IV for loading Aramany later, it was observed a stress concentration in the posterior region of the junction of the retaining plate of acrylic and the value of 18.336 MPa. In Class II Aramany in load was later observed a stress concentration in the anterior region near the boundary of the anterior resection worth 25.455 MPa. It was concluded that the quantitative values obtained in this study do not appear to present a risk of fracture of the metal frame CrCo alloy, but may present risks of failure in the metal retention / acrylic obturator prostesis . The configuration of palatal plate coating provides a better stress distribution along its surface.
2

Análise das tensões geradas por prótese obturadora maxilar implanto-retida por meio da análise de elementos finitos / Avaliation of stresses generated by the maxillary obturator prosthesis implant-retained by the finite element analysis

Sousa, Andréa Alves de 07 August 2012 (has links)
Neste estudo avaliou-se o comportamento biomecânico de próteses obturadoras maxilares Classe Ib, II e III de Okay retidas por implantes, observando as tensões geradas no tecido ósseo e gengivo-mucoso maxilar. A Análise de Elementos Finitos foi realizada empregando-se um modelo digital desenvolvido a partir de uma tomografia computadorizada de um indivíduo adulto. Utilizou-se o programa Rhinoceros® versão 4.0 SR9 para gerar o modelo maxilar BioCAD 3D, incorporando-se os modelos CAD dos implantes e UCLAS. Os implantes foram posicionados de acordo com cada modelo: Modelo 1 (Classe Ib de Okay): 6 implantes posicionados em regiões de caninos e incisivos laterais bilateralmente e em região de segundo premolar e primeiro molar esquerdos onde foram utilizados 4 clipes para o sistema de retenção barra/clipe; Modelo 2 (Classe II de Okay): 4 implantes posicionados em região de canino, incisivo lateral, segundo premolar e primeiro molar esquerdos, com 3 clipes; Modelo 3 (Classe III de Okay): 2 implantes posicionados em região de segundo premolar e primeiro molar esquerdos, com 2 clipes. A malha de elementos finitos foi gerada pelo programa Ansys®, tendo sido aplicada uma força de 80 N na plataforma oclusal, e de 35 N na plataforma incisal. Foi realizada uma análise qualitativa, correspondente à escala de tensão máxima principal, com valores quantitativos expressos em MPa. O deslocamento da prótese obturadora na região sem suporte ósseo aumentou em função da diminuição da área de suporte ósseo, do número de implantes e de clipes; a mucosa gengival, o osso cortical e o osso medular sofreram tensões de tração e de compressão que aumentaram em função da diminuição da área de suporte ósseo, do número de implantes e de clipes. Concluiu-se que quanto maior a perda da área de suporte ósseo em uma maxilectomia, maiores serão as forças de tensão e de compressão geradas pelo sistema de retenção barra/clipe nos tecidos remanescentes e maior será a tendência para o deslocamento da prótese. / Patients submitted to maxillectomy due to oral cancer shall be rehabilitated by means of obturator prosthesis in order to achieve a better quality of life. This study evaluated the biomechanics of implant-retained obturator prostheses analyzing the stress on maxillary osseous and gingivo-mucosal tissues. Finite elements analysis was developed using a 3D digital model based on a computed tomography of an adult man. Files were processed by Software Rhinoceros®, v4.0 SR9 and generated a maxillary BioCAD 3D model, which incorporated the CAD models of the implants and UCLAS. The implants were located considering: Model 1 (Okay Class Ib) - 6 implants in the areas of canines and lateral incisors and in the areas of left second premolar and molar, retention system bar/4 clips; Model 2 (Okay Class II ) - 4 implants located in the areas of canine, lateral incisor, left second premolar and first molar, retention system bar/3 clips; Model 3 (Okay Classe III) - 2 implants inserted in the left second premolar and first molar, retention system bar/2clips. The finite elements mesh was generate using Software Ansys®. A force of 80 N was applied to the occlusal platform and, at the same time, a force of 35 N was applied to the incisal platform of the obturator prosthesis. Results considered a qualitative analysis, based on the scale of maximum principal stress, and a quantitative analysis, when values were expressed in MPa. The dislodgement of the obturator prosthesis in the area with no osseous support increases as the area of the osseous support, the number of implants and clips diminish; the tensile and compressive stress in the gingival mucosa, the cortical and the alveolar bone increase as the osseous support, the number of implants and of clips diminish. The larger the area without osseous support, the higher the tensile and compressive stress in the remaining tissues and greater the displacement of the prosthesis.
3

Avaliação das tensões geradas nos componentes protéticos de próteses obturadoras maxilares classe I, II e IV de Aramany por meio de análise de elementos finitos / Evaluation of stress generated in maxillar obturators prosthesis of class I, II and IV of Aramany in Finite Element Analysis

Elcio Ricardo Miyashita 20 March 2013 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves sequelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de próteses obturadoras maxilares Classe I, II e IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 4.0 foi utilizado para a geração da malha de elementos finitos no programa Ansys Workbench 14.0®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores das próteses obturadoras, para observação das tensões geradas sobre as próteses obturadoras. Os resultados são apresentados sob a forma de análise qualitativa, indicada pelo estudo de Tensão Máxima Principal para as estruturas acrílicas da prótese e estudo de Von Mises para as estruturas metálicas da prótese, e análise quantitativa, representada por valores em Mega Pascal (MPa). Tanto nos carregamentos posteriores como nos carregamentos anteriores, foram observadas dissipações de cargas significativas localizadas na placa palatina próxima a ressecção e na junção do metal com o acrílico, sendo os maiores valores alcançados na placa de retenção metálica para retenção do acrílico localizada posteriormente na condição de carregamento posterior em ordem crescente na Classe II de Aramany com 149,17 MPa, Classe I de Aramany com 344,08 MPa e Classe IV de Aramany alcançando valor de 390,25 MPa. No acrílico da prótese obturadora, no caso de Classe I de Aramany em carregamento posterior, foi observada uma concentração de tensão principal na região correspondente ao limite lateral e anterior da junção da placa de retenção e do acrílico no valor de 19,796 MPa de tração. Na Classe IV de Aramany em carregamento posterior, foi observada uma concentração de tensão na região posterior da junção da placa de retenção e do acrílico no valor de 18,33 MPa. Na Classe II de Aramany, em carregamento posterior foi observada uma concentração de tensão na região anterior próxima ao limite da ressecção anterior no valor de 25,45 MPa de tração. Concluiu-se que os valores quantitativos alcançados neste estudo parecem não apresentar riscos de fratura sobre a armação metálica de liga de CrCo, porem podem apresentar riscos de falha na retenção metal/acrílico da prótese obturadora maxilar. A configuração de placa de recobrimento palatino proporciona uma melhor distribuição das tensões ao longo de sua superfície. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, determine the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class I,II andIV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 4.0 and then it was used to develop the finite element mesh in the software Ansys Workbench 14.0 ®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum stress and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that in the posterior loadings as in the anterior loadings were observed charge dissipation plate located in significant palate resection and near the junction of the metal with the acrylic and the highest values obtained in the metal retaining plate for retaining acrylic located further provided that subsequently loaded in ascending order in Class II Aramany with 149.17 MPa, Aramany with Class I and Class IV 344.08 MPa Aramany reaching value of 390.25 MPa. In acrylic prosthesis obturator in the case of Class I Aramany in subsequent loading, was observed a stress concentration in the region corresponding to the limit lateral and anterior junction of the retaining plate and the value of acrylic 19.796 MPa. Class IV for loading Aramany later, it was observed a stress concentration in the posterior region of the junction of the retaining plate of acrylic and the value of 18.336 MPa. In Class II Aramany in load was later observed a stress concentration in the anterior region near the boundary of the anterior resection worth 25.455 MPa. It was concluded that the quantitative values obtained in this study do not appear to present a risk of fracture of the metal frame CrCo alloy, but may present risks of failure in the metal retention / acrylic obturator prostesis . The configuration of palatal plate coating provides a better stress distribution along its surface.
4

Análise das tensões geradas por prótese obturadora maxilar implanto-retida por meio da análise de elementos finitos / Avaliation of stresses generated by the maxillary obturator prosthesis implant-retained by the finite element analysis

Andréa Alves de Sousa 07 August 2012 (has links)
Neste estudo avaliou-se o comportamento biomecânico de próteses obturadoras maxilares Classe Ib, II e III de Okay retidas por implantes, observando as tensões geradas no tecido ósseo e gengivo-mucoso maxilar. A Análise de Elementos Finitos foi realizada empregando-se um modelo digital desenvolvido a partir de uma tomografia computadorizada de um indivíduo adulto. Utilizou-se o programa Rhinoceros® versão 4.0 SR9 para gerar o modelo maxilar BioCAD 3D, incorporando-se os modelos CAD dos implantes e UCLAS. Os implantes foram posicionados de acordo com cada modelo: Modelo 1 (Classe Ib de Okay): 6 implantes posicionados em regiões de caninos e incisivos laterais bilateralmente e em região de segundo premolar e primeiro molar esquerdos onde foram utilizados 4 clipes para o sistema de retenção barra/clipe; Modelo 2 (Classe II de Okay): 4 implantes posicionados em região de canino, incisivo lateral, segundo premolar e primeiro molar esquerdos, com 3 clipes; Modelo 3 (Classe III de Okay): 2 implantes posicionados em região de segundo premolar e primeiro molar esquerdos, com 2 clipes. A malha de elementos finitos foi gerada pelo programa Ansys®, tendo sido aplicada uma força de 80 N na plataforma oclusal, e de 35 N na plataforma incisal. Foi realizada uma análise qualitativa, correspondente à escala de tensão máxima principal, com valores quantitativos expressos em MPa. O deslocamento da prótese obturadora na região sem suporte ósseo aumentou em função da diminuição da área de suporte ósseo, do número de implantes e de clipes; a mucosa gengival, o osso cortical e o osso medular sofreram tensões de tração e de compressão que aumentaram em função da diminuição da área de suporte ósseo, do número de implantes e de clipes. Concluiu-se que quanto maior a perda da área de suporte ósseo em uma maxilectomia, maiores serão as forças de tensão e de compressão geradas pelo sistema de retenção barra/clipe nos tecidos remanescentes e maior será a tendência para o deslocamento da prótese. / Patients submitted to maxillectomy due to oral cancer shall be rehabilitated by means of obturator prosthesis in order to achieve a better quality of life. This study evaluated the biomechanics of implant-retained obturator prostheses analyzing the stress on maxillary osseous and gingivo-mucosal tissues. Finite elements analysis was developed using a 3D digital model based on a computed tomography of an adult man. Files were processed by Software Rhinoceros®, v4.0 SR9 and generated a maxillary BioCAD 3D model, which incorporated the CAD models of the implants and UCLAS. The implants were located considering: Model 1 (Okay Class Ib) - 6 implants in the areas of canines and lateral incisors and in the areas of left second premolar and molar, retention system bar/4 clips; Model 2 (Okay Class II ) - 4 implants located in the areas of canine, lateral incisor, left second premolar and first molar, retention system bar/3 clips; Model 3 (Okay Classe III) - 2 implants inserted in the left second premolar and first molar, retention system bar/2clips. The finite elements mesh was generate using Software Ansys®. A force of 80 N was applied to the occlusal platform and, at the same time, a force of 35 N was applied to the incisal platform of the obturator prosthesis. Results considered a qualitative analysis, based on the scale of maximum principal stress, and a quantitative analysis, when values were expressed in MPa. The dislodgement of the obturator prosthesis in the area with no osseous support increases as the area of the osseous support, the number of implants and clips diminish; the tensile and compressive stress in the gingival mucosa, the cortical and the alveolar bone increase as the osseous support, the number of implants and of clips diminish. The larger the area without osseous support, the higher the tensile and compressive stress in the remaining tissues and greater the displacement of the prosthesis.
5

Avaliação das tensões ósseas geradas por prótese obturadora maxilar classe IV de Aramany por meio da análise de elementos finitos / Evaluation of the bone tensions generated in maxillary obturator prosthesis class IV of aramany through the analysis of finite elements

Miyashita, Elcio Ricardo 16 December 2008 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves seqüelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de uma prótese obturadora maxilar Classe IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 3.0 foi utilizado para a geração da malha de elementos finitos no programa FEMAP/NASTRAN®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores da prótese obturadora, para observação das forças de tensão geradas no tecido ósseo maxilar. Os resultados são apresentados sob a forma de análise qualitativa, indicada pela escala de Tensão Máxima Principal, e análise quantitativa, representada por valores em Mega Pascal (MPa). Observou-se que o carregamento posterior provoca tensão de tração e tensão de compressão, independentemente da região óssea avaliada, induz a uma maior tensão de tração em todas as regiões ósseas observadas e a uma maior tensão de compressão na região média anterior do palato. O carregamento anterior gera tensão de tração em todas as regiões ósseas consideradas e acarreta maior tensão de tração do que tensão de compressão, independentemente da região óssea avaliada. Concluiu-se que ocorre uma tendência de rotação da prótese em direção à área de ressecção cirúrgica, tanto para o carregamento posterior como para o carregamento anterior. O nível das tensões de tração e de compressão observado neste estudo indica que o comportamento biomecânico da prótese obturadora maxilar Classe IV de Aramany encontra-se dentro dos limites fisiológicos do tecido ósseo maxilar. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, enjoin the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class IV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 3.0 and then it was used to develop the finite element mesh in the software FEMAP/NASTRAN®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum Tension Scale and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that the posterior load generates tensile and compression stress and a higher tension stress regardless of the osseous region, as well as a higher compression stress on the anterior medial area of residual palate. Anterior load provokes tensile stress in each of the osseous regions evaluated, in addition to a higher tensile then compression stresses, despite of the osseous region. Therefore, it was concluded that the prostheses tends to rotate towards surgical resection areas during posterior and anterior loading. The amount of tensile and compression stresses observed herein indicates that the biomechanical behavior of Aramany Class IV obturator prostheses is within the physiological limits of the maxillary osseous tissue.
6

Avaliação das tensões ósseas geradas por prótese obturadora maxilar classe IV de Aramany por meio da análise de elementos finitos / Evaluation of the bone tensions generated in maxillary obturator prosthesis class IV of aramany through the analysis of finite elements

Elcio Ricardo Miyashita 16 December 2008 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves seqüelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de uma prótese obturadora maxilar Classe IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 3.0 foi utilizado para a geração da malha de elementos finitos no programa FEMAP/NASTRAN®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores da prótese obturadora, para observação das forças de tensão geradas no tecido ósseo maxilar. Os resultados são apresentados sob a forma de análise qualitativa, indicada pela escala de Tensão Máxima Principal, e análise quantitativa, representada por valores em Mega Pascal (MPa). Observou-se que o carregamento posterior provoca tensão de tração e tensão de compressão, independentemente da região óssea avaliada, induz a uma maior tensão de tração em todas as regiões ósseas observadas e a uma maior tensão de compressão na região média anterior do palato. O carregamento anterior gera tensão de tração em todas as regiões ósseas consideradas e acarreta maior tensão de tração do que tensão de compressão, independentemente da região óssea avaliada. Concluiu-se que ocorre uma tendência de rotação da prótese em direção à área de ressecção cirúrgica, tanto para o carregamento posterior como para o carregamento anterior. O nível das tensões de tração e de compressão observado neste estudo indica que o comportamento biomecânico da prótese obturadora maxilar Classe IV de Aramany encontra-se dentro dos limites fisiológicos do tecido ósseo maxilar. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, enjoin the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class IV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 3.0 and then it was used to develop the finite element mesh in the software FEMAP/NASTRAN®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum Tension Scale and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that the posterior load generates tensile and compression stress and a higher tension stress regardless of the osseous region, as well as a higher compression stress on the anterior medial area of residual palate. Anterior load provokes tensile stress in each of the osseous regions evaluated, in addition to a higher tensile then compression stresses, despite of the osseous region. Therefore, it was concluded that the prostheses tends to rotate towards surgical resection areas during posterior and anterior loading. The amount of tensile and compression stresses observed herein indicates that the biomechanical behavior of Aramany Class IV obturator prostheses is within the physiological limits of the maxillary osseous tissue.

Page generated in 0.0958 seconds