Spelling suggestions: "subject:"compression stress"" "subject:"8compression stress""
1 |
Deformations of helical fibres under uniformly and non-uniformly distributed compressive forcesTandon, Surinder Kumar January 1988 (has links)
No description available.
|
2 |
Avaliação das tensões ósseas geradas por prótese obturadora maxilar classe IV de Aramany por meio da análise de elementos finitos / Evaluation of the bone tensions generated in maxillary obturator prosthesis class IV of aramany through the analysis of finite elementsMiyashita, Elcio Ricardo 16 December 2008 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves seqüelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de uma prótese obturadora maxilar Classe IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 3.0 foi utilizado para a geração da malha de elementos finitos no programa FEMAP/NASTRAN®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores da prótese obturadora, para observação das forças de tensão geradas no tecido ósseo maxilar. Os resultados são apresentados sob a forma de análise qualitativa, indicada pela escala de Tensão Máxima Principal, e análise quantitativa, representada por valores em Mega Pascal (MPa). Observou-se que o carregamento posterior provoca tensão de tração e tensão de compressão, independentemente da região óssea avaliada, induz a uma maior tensão de tração em todas as regiões ósseas observadas e a uma maior tensão de compressão na região média anterior do palato. O carregamento anterior gera tensão de tração em todas as regiões ósseas consideradas e acarreta maior tensão de tração do que tensão de compressão, independentemente da região óssea avaliada. Concluiu-se que ocorre uma tendência de rotação da prótese em direção à área de ressecção cirúrgica, tanto para o carregamento posterior como para o carregamento anterior. O nível das tensões de tração e de compressão observado neste estudo indica que o comportamento biomecânico da prótese obturadora maxilar Classe IV de Aramany encontra-se dentro dos limites fisiológicos do tecido ósseo maxilar. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, enjoin the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class IV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 3.0 and then it was used to develop the finite element mesh in the software FEMAP/NASTRAN®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum Tension Scale and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that the posterior load generates tensile and compression stress and a higher tension stress regardless of the osseous region, as well as a higher compression stress on the anterior medial area of residual palate. Anterior load provokes tensile stress in each of the osseous regions evaluated, in addition to a higher tensile then compression stresses, despite of the osseous region. Therefore, it was concluded that the prostheses tends to rotate towards surgical resection areas during posterior and anterior loading. The amount of tensile and compression stresses observed herein indicates that the biomechanical behavior of Aramany Class IV obturator prostheses is within the physiological limits of the maxillary osseous tissue.
|
3 |
Avaliação das tensões ósseas geradas por prótese obturadora maxilar classe IV de Aramany por meio da análise de elementos finitos / Evaluation of the bone tensions generated in maxillary obturator prosthesis class IV of aramany through the analysis of finite elementsElcio Ricardo Miyashita 16 December 2008 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves seqüelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de uma prótese obturadora maxilar Classe IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 3.0 foi utilizado para a geração da malha de elementos finitos no programa FEMAP/NASTRAN®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores da prótese obturadora, para observação das forças de tensão geradas no tecido ósseo maxilar. Os resultados são apresentados sob a forma de análise qualitativa, indicada pela escala de Tensão Máxima Principal, e análise quantitativa, representada por valores em Mega Pascal (MPa). Observou-se que o carregamento posterior provoca tensão de tração e tensão de compressão, independentemente da região óssea avaliada, induz a uma maior tensão de tração em todas as regiões ósseas observadas e a uma maior tensão de compressão na região média anterior do palato. O carregamento anterior gera tensão de tração em todas as regiões ósseas consideradas e acarreta maior tensão de tração do que tensão de compressão, independentemente da região óssea avaliada. Concluiu-se que ocorre uma tendência de rotação da prótese em direção à área de ressecção cirúrgica, tanto para o carregamento posterior como para o carregamento anterior. O nível das tensões de tração e de compressão observado neste estudo indica que o comportamento biomecânico da prótese obturadora maxilar Classe IV de Aramany encontra-se dentro dos limites fisiológicos do tecido ósseo maxilar. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, enjoin the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class IV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 3.0 and then it was used to develop the finite element mesh in the software FEMAP/NASTRAN®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum Tension Scale and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that the posterior load generates tensile and compression stress and a higher tension stress regardless of the osseous region, as well as a higher compression stress on the anterior medial area of residual palate. Anterior load provokes tensile stress in each of the osseous regions evaluated, in addition to a higher tensile then compression stresses, despite of the osseous region. Therefore, it was concluded that the prostheses tends to rotate towards surgical resection areas during posterior and anterior loading. The amount of tensile and compression stresses observed herein indicates that the biomechanical behavior of Aramany Class IV obturator prostheses is within the physiological limits of the maxillary osseous tissue.
|
4 |
Caracterização da relaxação por compressão de borracha acrílica irradiada. / Compression relaxation characterization of irradiated acrylic rubber.Santos, Demetrio Jackson dos 11 February 2011 (has links)
Este trabalho tem como objetivo investigar a redução da relaxação por compressão de borracha acrílica modificada (ACM) irradiada por feixe de elétrons, através da caracterização de seu comportamento mecânico e de sua estrutura molecular. O material, nas condições original e irradiado, foi inicialmente submetido a ensaios uniaxiais de tração e espectroscopia por infravermelho com o objetivo de verificar a influência da irradiação EB em seu comportamento, eliminando a possibilidade de degradação do material, permitindo a continuidade dos estudos. Definidas as doses, novos corpos de prova foram irradiados e submetidos a ensaios uniaxiais, equibiaxiais de tensão e cisalhamento puro, gerando resultados que foram aplicados na simulação pelo método de elementos finitos, utilizando o modelo de comportamento elástico não-linear de Ogden, para predizer o comportamento do material em condições de compressão. Confirmado o aumento da tensão por compressão para mesmas deformações, com o aumento da dose de radiação, análises termogravimétricas e dinâmicas mecânicas foram realizadas para possibilitar o entendimento do fenômeno. Na fase final do trabalho ensaios de relaxação por compressão foram realizados, em diferentes níveis de deformação e temperatura, apresentando a redução da relaxação por compressão gerada pela radiação EB e quantificando tal influência combinada com outros fatores, através da aplicação dos resultados no método de Planejamento Fatorial 2k. / The aim of this work is to investigate the compression stress relaxation (CSR) decrease of modified acrylic rubber, irradiated by electron beam, through its mechanical behavior and molecular structure characterization. Uniaxial tensile test and infrared spectroscopy were carried out, on original and irradiated material conditions, to verify the influence of EB irradiation on ACM, and to eliminate the possibility of degradation caused by EB radiation. After to define the radiation doses, new ACM specimens were irradiated. Uniaxial, equibiaxial and planar shear tests generated experimental data, which were applied to simulate the non linear elastic behavior of the material, through finite elements method, using the Ogden Model. Confirmed the compression stress increase at same deformation level, caused by increasing of radiation dose, thermogravimetric and dynamic mechanical analysis were carried out in order to make possible to understand the behavior changes. In the final part of this work, compression stress relaxation experiments were carried out, at two deformation and temperature levels, with the purpose to validate the compression stress relaxation decrease caused by EB radiation, and to quantify such influence combined with other factors. The CSR decrease combined with other influence variables were studied through use of factorial design.
|
5 |
Caracterização da relaxação por compressão de borracha acrílica irradiada. / Compression relaxation characterization of irradiated acrylic rubber.Demetrio Jackson dos Santos 11 February 2011 (has links)
Este trabalho tem como objetivo investigar a redução da relaxação por compressão de borracha acrílica modificada (ACM) irradiada por feixe de elétrons, através da caracterização de seu comportamento mecânico e de sua estrutura molecular. O material, nas condições original e irradiado, foi inicialmente submetido a ensaios uniaxiais de tração e espectroscopia por infravermelho com o objetivo de verificar a influência da irradiação EB em seu comportamento, eliminando a possibilidade de degradação do material, permitindo a continuidade dos estudos. Definidas as doses, novos corpos de prova foram irradiados e submetidos a ensaios uniaxiais, equibiaxiais de tensão e cisalhamento puro, gerando resultados que foram aplicados na simulação pelo método de elementos finitos, utilizando o modelo de comportamento elástico não-linear de Ogden, para predizer o comportamento do material em condições de compressão. Confirmado o aumento da tensão por compressão para mesmas deformações, com o aumento da dose de radiação, análises termogravimétricas e dinâmicas mecânicas foram realizadas para possibilitar o entendimento do fenômeno. Na fase final do trabalho ensaios de relaxação por compressão foram realizados, em diferentes níveis de deformação e temperatura, apresentando a redução da relaxação por compressão gerada pela radiação EB e quantificando tal influência combinada com outros fatores, através da aplicação dos resultados no método de Planejamento Fatorial 2k. / The aim of this work is to investigate the compression stress relaxation (CSR) decrease of modified acrylic rubber, irradiated by electron beam, through its mechanical behavior and molecular structure characterization. Uniaxial tensile test and infrared spectroscopy were carried out, on original and irradiated material conditions, to verify the influence of EB irradiation on ACM, and to eliminate the possibility of degradation caused by EB radiation. After to define the radiation doses, new ACM specimens were irradiated. Uniaxial, equibiaxial and planar shear tests generated experimental data, which were applied to simulate the non linear elastic behavior of the material, through finite elements method, using the Ogden Model. Confirmed the compression stress increase at same deformation level, caused by increasing of radiation dose, thermogravimetric and dynamic mechanical analysis were carried out in order to make possible to understand the behavior changes. In the final part of this work, compression stress relaxation experiments were carried out, at two deformation and temperature levels, with the purpose to validate the compression stress relaxation decrease caused by EB radiation, and to quantify such influence combined with other factors. The CSR decrease combined with other influence variables were studied through use of factorial design.
|
Page generated in 0.1048 seconds