• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação in vitro da resistência de união à tração de três tipos de pinos de fibra cimentados a raízes bovinas com diferentes cimentos resinosos / In vitro evaluation of tensile bond strength of three types of fiber posts luted in bovine roots with different resin cements

Quintero, Mayra Zamboni 20 September 2012 (has links)
Este estudo teve como objetivo avaliar, através de testes de tração, a resistência de união de pinos pré-fabricados, com diferentes graus de translucidez, à dentina bovina, utilizando três tipos de cimentos resinosos. Noventa incisivos bovinos tiveram suas coroas anatômicas separadas das raízes através de uma secção perpendicular ao longo eixo dos dentes na junção amelocementária, de modo que as raízes apresentassem 14 mm de comprimento. Os condutos radiculares foram tratados endodonticamente e os espécimes, mantidos em água destilada a 37°C por 7 dias. Após esse período, foi realizada a desobturação de 7 mm de profundidade de cada conduto para a cimentação dos três tipos de pino: Exacto (Angelus), translúcido; Reforpost fibra de vidro (Angelus), branco; e Reforpost fibra de carbono (Angelus), negro e opaco. Três tipos de cimentos resinosos foram utilizados de acordo com as recomendações dos fabricantes: o cimento dual auto-adesivo Rely X U100 (3M ESPE); o cimento dual Rely X ARC (3M ESPE), associado ao sistema adesivo autopolimerizável Scotchbond Multi-Uso Plus (3M ESPE); e o cimento de ação exclusivamente química Cement Post (Angelus), associado ao sistema adesivo Fusion Duralink (Angelus), constituindo 9 grupos experimentais (n=10). Após a armazenagem dos corpos de prova em água destilada a 37º C por 7 dias, foi realizado o teste de tração no aparelho de ensaio mecânico da marca Kratos Equipamentos, a uma velocidade de 0,5mm/min até a ruptura dos mesmos. Para determinar a tensão de tração, foi calculada a área de adesão de cada espécime. Os dados foram analisados estatisticamente através da Análise de Variância e do teste de Kruskal-Wallis, com grau de significância de 5%. Os espécimes foram examinados através de um microscópio óptico Olympus (Tokyo, Japão), com 20x de aumento, para avaliação do modo de fratura. Em relação às variáveis estudadas, verificou-se que: o pino Exacto, com maior translucidez e maior conicidade, apresentou valores de resistência à tração significativamente inferiores do que os pinos Reforpost Fibra de Vidro e Reforpost Fibra de Carbono, quando utilizado o cimento Rely X ARC; o cimento dual auto-adesivo Rely X U100 apresentou menores valores de resistência à tração do que cimento dual Rely X ARC quando utilizados os pinos Reforpost Fibra de Vidro e Reforpost Fibra de Carbono; e o cimento de polimerização química Cement Post apresentou menores valores de resistência à tração em relação aos cimentos duais, independente do tipo de pino testado. Quanto à análise microscópica, observou-se que os cimentos resinosos aderiram mais aos pinos do que à dentina radicular. Portanto, a translucidez dos pinos não contribuiu para aumentar a resistência à tração dos cimentos resinosos duais em nenhum dos grupos testados. / This study aimed to evaluate, through tensile test, the bond strength of prefabricated posts with different degrees of translucency, using three types of resin cements. Ninety bovine incisors were selected and sectioned at the cemento-enamel junction. The root canals were endodontically treated and the specimens were stored in distilled water at 37°C for 7 days. After this period, a 7-mm-deep post space was prepared for the cementation of three types of posts: Exacto (Angelus), translucent; Fiberglass Reforpost (Angelus), white; and Carbon Fiber Reforpost (Angelus), black and opaque. Three types of resin cements were used according to manufacturers\' instructions: the self-adhesive dual cement Rely X U100 (3M ESPE); the dual cement Rely X ARC (3M ESPE), associated with autopolymerized adhesive system Scotchbond Multi-Uso Plus (3M ESPE), and the self-cured cement Cement Post (Angelus), associated with the autopolymerized adhesive system Fusion Duralink (Angelus), constituting nine experimental groups (n = 10). After the storage of the specimens in distilled water at 37°C for 7 days, the tensile test was performed with a universal test machine at a crosshead speed of 0.5 mm/min. To determine the bond strength, the bonding area of each specimen was calculated. The data were statistically analyzed by ANOVA followed by Kruskal-Wallis test, with a significance level of 5%. The dislodged posts were examined microscopically (Olympus; Tokyo, Japan) at x20 magnification to determine the type of failure. Regarding the variables studied, it was found that: the Exacto post, more translucent and tapered, had significantly lower tensile bond strength than Fiberglass Reforpost and Carbon Fiber Reforpost when used the dual cement Rely X ARC; the dual self-adhesive cement Rely X U100 showed lower tensile bond strength than the dual cement Rely X ARC, when used Fiberglass Reforpost and Carbon Fiber Reforpost; regardless of the type of post tested, the self-cured cement Cement Post had lower tensile strength compared to dual cements. It was observed microscopically that resin cements adhered more to the posts than to the root dentin. Therefore, the translucency of the posts had not contributed to increase the tensile strength of dual-curing resin cements in all groups tested.
2

Avaliação das tensões ósseas geradas por prótese obturadora maxilar classe IV de Aramany por meio da análise de elementos finitos / Evaluation of the bone tensions generated in maxillary obturator prosthesis class IV of aramany through the analysis of finite elements

Miyashita, Elcio Ricardo 16 December 2008 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves seqüelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de uma prótese obturadora maxilar Classe IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 3.0 foi utilizado para a geração da malha de elementos finitos no programa FEMAP/NASTRAN®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores da prótese obturadora, para observação das forças de tensão geradas no tecido ósseo maxilar. Os resultados são apresentados sob a forma de análise qualitativa, indicada pela escala de Tensão Máxima Principal, e análise quantitativa, representada por valores em Mega Pascal (MPa). Observou-se que o carregamento posterior provoca tensão de tração e tensão de compressão, independentemente da região óssea avaliada, induz a uma maior tensão de tração em todas as regiões ósseas observadas e a uma maior tensão de compressão na região média anterior do palato. O carregamento anterior gera tensão de tração em todas as regiões ósseas consideradas e acarreta maior tensão de tração do que tensão de compressão, independentemente da região óssea avaliada. Concluiu-se que ocorre uma tendência de rotação da prótese em direção à área de ressecção cirúrgica, tanto para o carregamento posterior como para o carregamento anterior. O nível das tensões de tração e de compressão observado neste estudo indica que o comportamento biomecânico da prótese obturadora maxilar Classe IV de Aramany encontra-se dentro dos limites fisiológicos do tecido ósseo maxilar. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, enjoin the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class IV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 3.0 and then it was used to develop the finite element mesh in the software FEMAP/NASTRAN®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum Tension Scale and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that the posterior load generates tensile and compression stress and a higher tension stress regardless of the osseous region, as well as a higher compression stress on the anterior medial area of residual palate. Anterior load provokes tensile stress in each of the osseous regions evaluated, in addition to a higher tensile then compression stresses, despite of the osseous region. Therefore, it was concluded that the prostheses tends to rotate towards surgical resection areas during posterior and anterior loading. The amount of tensile and compression stresses observed herein indicates that the biomechanical behavior of Aramany Class IV obturator prostheses is within the physiological limits of the maxillary osseous tissue.
3

Avaliação in vitro da resistência de união à tração de três tipos de pinos de fibra cimentados a raízes bovinas com diferentes cimentos resinosos / In vitro evaluation of tensile bond strength of three types of fiber posts luted in bovine roots with different resin cements

Mayra Zamboni Quintero 20 September 2012 (has links)
Este estudo teve como objetivo avaliar, através de testes de tração, a resistência de união de pinos pré-fabricados, com diferentes graus de translucidez, à dentina bovina, utilizando três tipos de cimentos resinosos. Noventa incisivos bovinos tiveram suas coroas anatômicas separadas das raízes através de uma secção perpendicular ao longo eixo dos dentes na junção amelocementária, de modo que as raízes apresentassem 14 mm de comprimento. Os condutos radiculares foram tratados endodonticamente e os espécimes, mantidos em água destilada a 37°C por 7 dias. Após esse período, foi realizada a desobturação de 7 mm de profundidade de cada conduto para a cimentação dos três tipos de pino: Exacto (Angelus), translúcido; Reforpost fibra de vidro (Angelus), branco; e Reforpost fibra de carbono (Angelus), negro e opaco. Três tipos de cimentos resinosos foram utilizados de acordo com as recomendações dos fabricantes: o cimento dual auto-adesivo Rely X U100 (3M ESPE); o cimento dual Rely X ARC (3M ESPE), associado ao sistema adesivo autopolimerizável Scotchbond Multi-Uso Plus (3M ESPE); e o cimento de ação exclusivamente química Cement Post (Angelus), associado ao sistema adesivo Fusion Duralink (Angelus), constituindo 9 grupos experimentais (n=10). Após a armazenagem dos corpos de prova em água destilada a 37º C por 7 dias, foi realizado o teste de tração no aparelho de ensaio mecânico da marca Kratos Equipamentos, a uma velocidade de 0,5mm/min até a ruptura dos mesmos. Para determinar a tensão de tração, foi calculada a área de adesão de cada espécime. Os dados foram analisados estatisticamente através da Análise de Variância e do teste de Kruskal-Wallis, com grau de significância de 5%. Os espécimes foram examinados através de um microscópio óptico Olympus (Tokyo, Japão), com 20x de aumento, para avaliação do modo de fratura. Em relação às variáveis estudadas, verificou-se que: o pino Exacto, com maior translucidez e maior conicidade, apresentou valores de resistência à tração significativamente inferiores do que os pinos Reforpost Fibra de Vidro e Reforpost Fibra de Carbono, quando utilizado o cimento Rely X ARC; o cimento dual auto-adesivo Rely X U100 apresentou menores valores de resistência à tração do que cimento dual Rely X ARC quando utilizados os pinos Reforpost Fibra de Vidro e Reforpost Fibra de Carbono; e o cimento de polimerização química Cement Post apresentou menores valores de resistência à tração em relação aos cimentos duais, independente do tipo de pino testado. Quanto à análise microscópica, observou-se que os cimentos resinosos aderiram mais aos pinos do que à dentina radicular. Portanto, a translucidez dos pinos não contribuiu para aumentar a resistência à tração dos cimentos resinosos duais em nenhum dos grupos testados. / This study aimed to evaluate, through tensile test, the bond strength of prefabricated posts with different degrees of translucency, using three types of resin cements. Ninety bovine incisors were selected and sectioned at the cemento-enamel junction. The root canals were endodontically treated and the specimens were stored in distilled water at 37°C for 7 days. After this period, a 7-mm-deep post space was prepared for the cementation of three types of posts: Exacto (Angelus), translucent; Fiberglass Reforpost (Angelus), white; and Carbon Fiber Reforpost (Angelus), black and opaque. Three types of resin cements were used according to manufacturers\' instructions: the self-adhesive dual cement Rely X U100 (3M ESPE); the dual cement Rely X ARC (3M ESPE), associated with autopolymerized adhesive system Scotchbond Multi-Uso Plus (3M ESPE), and the self-cured cement Cement Post (Angelus), associated with the autopolymerized adhesive system Fusion Duralink (Angelus), constituting nine experimental groups (n = 10). After the storage of the specimens in distilled water at 37°C for 7 days, the tensile test was performed with a universal test machine at a crosshead speed of 0.5 mm/min. To determine the bond strength, the bonding area of each specimen was calculated. The data were statistically analyzed by ANOVA followed by Kruskal-Wallis test, with a significance level of 5%. The dislodged posts were examined microscopically (Olympus; Tokyo, Japan) at x20 magnification to determine the type of failure. Regarding the variables studied, it was found that: the Exacto post, more translucent and tapered, had significantly lower tensile bond strength than Fiberglass Reforpost and Carbon Fiber Reforpost when used the dual cement Rely X ARC; the dual self-adhesive cement Rely X U100 showed lower tensile bond strength than the dual cement Rely X ARC, when used Fiberglass Reforpost and Carbon Fiber Reforpost; regardless of the type of post tested, the self-cured cement Cement Post had lower tensile strength compared to dual cements. It was observed microscopically that resin cements adhered more to the posts than to the root dentin. Therefore, the translucency of the posts had not contributed to increase the tensile strength of dual-curing resin cements in all groups tested.
4

Avaliação das tensões ósseas geradas por prótese obturadora maxilar classe IV de Aramany por meio da análise de elementos finitos / Evaluation of the bone tensions generated in maxillary obturator prosthesis class IV of aramany through the analysis of finite elements

Elcio Ricardo Miyashita 16 December 2008 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves seqüelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de uma prótese obturadora maxilar Classe IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 3.0 foi utilizado para a geração da malha de elementos finitos no programa FEMAP/NASTRAN®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores da prótese obturadora, para observação das forças de tensão geradas no tecido ósseo maxilar. Os resultados são apresentados sob a forma de análise qualitativa, indicada pela escala de Tensão Máxima Principal, e análise quantitativa, representada por valores em Mega Pascal (MPa). Observou-se que o carregamento posterior provoca tensão de tração e tensão de compressão, independentemente da região óssea avaliada, induz a uma maior tensão de tração em todas as regiões ósseas observadas e a uma maior tensão de compressão na região média anterior do palato. O carregamento anterior gera tensão de tração em todas as regiões ósseas consideradas e acarreta maior tensão de tração do que tensão de compressão, independentemente da região óssea avaliada. Concluiu-se que ocorre uma tendência de rotação da prótese em direção à área de ressecção cirúrgica, tanto para o carregamento posterior como para o carregamento anterior. O nível das tensões de tração e de compressão observado neste estudo indica que o comportamento biomecânico da prótese obturadora maxilar Classe IV de Aramany encontra-se dentro dos limites fisiológicos do tecido ósseo maxilar. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, enjoin the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class IV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 3.0 and then it was used to develop the finite element mesh in the software FEMAP/NASTRAN®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum Tension Scale and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that the posterior load generates tensile and compression stress and a higher tension stress regardless of the osseous region, as well as a higher compression stress on the anterior medial area of residual palate. Anterior load provokes tensile stress in each of the osseous regions evaluated, in addition to a higher tensile then compression stresses, despite of the osseous region. Therefore, it was concluded that the prostheses tends to rotate towards surgical resection areas during posterior and anterior loading. The amount of tensile and compression stresses observed herein indicates that the biomechanical behavior of Aramany Class IV obturator prostheses is within the physiological limits of the maxillary osseous tissue.
5

Influência do fator mecânico na formação de lesões cervicais não cariosas / Influence of the mechanical factor on the formation of non-carious cervical lesions

Solis, Myriam Katherine Zurita 14 November 2018 (has links)
Lesões cervicais não cariosas têm etiologia multifatorial, com ênfase na ação de ácidos, abrasivos e cargas mecânicas aplicadas à distância do local da lesão, mas que concentram tensão na região cervical, que é o local da lesão. O mecanismo de ação das cargas aplicadas à distância não foi ainda elucidado. Pensou-se que seria mediado por micro fraturas que fariam se desprender fragmentos de tecido (abfração); mas isto não explicaria a formação de lesões produzidas na presença de compressão, mesmo concentrada, nem a interação sinérgica na presença de ácidos. Além disso, as fraturas nunca foram localizadas no tecido. Uma outra hipótese considera os tecidos dentários como esponjas rígidas, deformáveis, capazes de expelir a sua própria água quando comprimidos ou absorver fluidos circundantes quando tracionados. Quando a carga fosse removida e o tecido recuperasse sua forma original, o fluido faria o caminho inverso. Assim, a ciclagem mecânica forçaria a circulação de fluidos circundantes no tecido e, se fossem ácidos, facilitaria a dissolução do tecido, tanto sob tração quanto sob compressão. A proposta do estudo foi avaliar a penetração de fluido traçador (nitrato de prata a 10 %) no esmalte de espécimes submetidos ou não a cargas cíclicas excêntricas que provocam compressão ou tração. Os espécimes foram construídos a partir de incisivos bovinos, cortados em paralelepípedos de 3x3x8,2 mm, com entalhe na dentina para formar um pescoço de 2x2 mm de seção transversal. Os espécimes, exceto uma faixa central do esmalte vestibular de 1,5x5 mm foram protegidos da penetração do traçador com verniz. Foram aplicados 1.200 ciclos mecânicos de carga excêntrica para produzir tensões de tração ou compressão no esmalte, com 5 s de carga de 40 N e 25 s sem carga. Um grupo controle não recebeu nem carga nem exposição ao traçador; outro controle recebeu apenas exposição ao traçador, sem carga; outros dois grupos controles receberam carga (de tração ou compressão) enquanto imersos em água e, imediatamente depois, foram expostos ao traçador durante 600 min. Os dois grupos teste foram expostos simultaneamente aos ciclos de carga (de tração ou de compressão) e ao traçador. A prata do traçador foi precipitada por exposição a fixador radiográfico e, posteriormente, à luz de fotopolimerizador (5 min). Para localizar o traçador os espécimes foram micro tomografados, radiografados e, posteriormente, foram cortados longitudinalmente para obter uma fatia central de 1 mm de espessura para avaliação em lupa, com luz refletida ou transmitida. A micro tomografia foi ineficaz devido aos artefatos formados. As radiografias marcaram apenas as regiões de maior concentração do traçador. A avaliação dos cortes em lupa binocular permitiu concluir que existem variações de padrão de coloração natural do esmalte de incisivos bovinos, que todos os espécimes expostos ao traçador, independentemente do grupo experimental, apresentaram alguma infiltração, pelo menos numa camada fina e uniforme da superfície exposta. Além da fina camada marcada, existe variação de padrões de penetração do traçador, mesmo entre os que receberam um mesmo tratamento experimental, o que pode ser devido a variações inevitáveis no histórico de cada dente. Isto, apesar de se tornar um inconveniente para identificar um possível efeito de bombeamento, poderia ser identificado também como um indicador de que podem existir diferenças na velocidade e profundidade de penetração no esmalte de outras moléculas como, por exemplo, as dos ácidos. Em resumo, o corante traçador penetrou no esmalte dos espécimes de incisivos bovinos sem diferenças claras de padrão de penetração entre os diferentes grupos e pode ser um método eficaz para comprovar a hipótese de circulação forçada, mas exigirá novos estudos. / Non-carious cervical lesions have a multifactorial aetiology, with emphasis on the action of acids, abrasives and mechanical loads applied at a distance from the site of the lesion, which concentrates tension at the lesion site. The mechanism of action of loads applied at a distance has not yet been elucidated. It was thought that it would be mediated by microfractures that would cause fragments of tissue (abfração) to be released, but this would not explain the formation of lesions produced in the presence of compression, even concentrated, nor the synergistic interaction in the presence of acids. Also, no fractures were located in the tissue. Another hypothesis considers dental tissues as rigid, deformable sponges capable of expelling their water when compressed or absorbing surrounding fluids under traction. When the load was removed, and the tissue regained its original shape, the fluid would do the reverse way. Thus, mechanical cycling would force the circulation of surrounding fluids into the tissue and, if they were acidic, would facilitate dissolution of the tissue, both under traction and under compression. The study aimed to evaluate the penetration of tracer fluid (10% silver nitrate) in the enamel of specimens subjected or not to eccentric cyclic loads that cause compression or traction. The specimens were constructed from bovine incisors, cut in parallelepipeds of 3x3x8.2 mm, with a notch in dentin to form a neck of 2x2 mm cross-section. The specimens, except a central vestibular enamel strip of 1.5x5 mm, were protected from penetration of the tracer with varnish. 1,200 eccentric load mechanical cycles were applied to produce tension or compression in the enamel, with 5 s of 40 N load and 25 s without load. A control group received neither load nor exposure to the tracer; another control received only exposure to the tracer, without load; two other control groups received loading (tensile or compression) while immersed in water and immediately exposed to the tracer for 600 min. The two test groups were exposed simultaneously to the load (traction or compression) cycles and the tracer. The silver from the tracer was precipitated by exposure to a radiographic fixer and, subsequently, by the light of a curing light source (5 min). To locate the tracer the specimens were micro-scanned, radiographed and later cut longitudinally to obtain a central slice of 1 mm thickness for evaluation in a magnifying glass, light reflected or transmitted. Microtomography was ineffective due to artefacts formed. The radiographs marked only the regions with the highest concentration of the tracer. The evaluation with stereo microscopy allowed to conclude that there are variations in the natural staining pattern of bovine incisor enamel; that all the specimens exposed to the tracer, independently of the experimental group, showed some infiltration, at least in a thin and uniform layer of the exposed surface. In addition to the thin layer marked, there is a variation of tracer penetration patterns, even among those who received the same experimental treatment, which may be due to inevitable variations in the history of each tooth. This fact, although an inconvenience to identify a possible pumping effect, could also be identified as an indicator that there may be differences in the speed and depth of enamel penetration of other molecules, such as those of acids. In summary, tracer dye penetrated the enamel of bovine incisor specimens without clear differences in penetration pattern between the different groups and may be an effective method to prove the hypothesis of forced circulation, but will require further studies.

Page generated in 0.0799 seconds