• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 110
  • 30
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 157
  • 55
  • 50
  • 47
  • 46
  • 39
  • 34
  • 29
  • 28
  • 28
  • 25
  • 21
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Clinical outcome measures of a non-drug preventive therapy for migraine

Nusair, Yanal M. H. January 2000 (has links)
No description available.
2

Effects of active vertical corrector treatment in growing anterior open-bite patients a thesis submitted in partial fulfillment ... for the degree of Master of Science in Orthodontics ... /

Cavanaugh, Catherine E. January 1995 (has links)
Thesis (M.S.)--University of Michigan, 1995. / Includes bibliographical references.
3

Impact of instructions on the pain-reducing ability of mouth guards for the treatment of temporomandibular disorders

Owais, Zaidoon Rakad, Glaros, Alan G., January 2005 (has links)
Thesis (M.S.)--School of Dentistry. University of Missouri--Kansas City, 2005. / "A thesis in oral biology." Advisor: Alan G. Glaros. Typescript. Vita. Title from "catalog record" of the print edition Description based on contents viewed March 12, 2007. Includes bibliographical references (leaves 109-114 ). Online version of the print edition.
4

Análise da resistência à flexão e da microdureza de resinas acrílicas utilizadas para confecção de placas interoclusais /

Costa, Patrícia dos Santos. January 2006 (has links)
Resumo: As placas interoclusais podem ser confeccionadas por meio de várias técnicas, sendo a resina acrílica o material de escolha mais difundido atualmente. Devido ao fato de as placas serem submetidas a diferentes tipos de forças por um longoperíodo no interior da cavidade bucal, estas podem fraturar-se ou desgastar-se com facilidade. O objetivo do presente estudo foi avaliar e comparar, por meio de ensaio de resistência à flexão e teste de microdureza Knoop, o comportamento das resinas acrílicas térmica e quimicamente ativadas utilizadas na confecção de placas interoclusais, variando-se as técnicas de confecção e processamento. Para tanto, foram confeccionados 60 espécimes divididos em seis grupos (GI, GII, GIII, GIV, GV, GVI), de acordo com o tipo de resina e técnica de processamento utilizadas. Os grupos GI e GII utilizaram resina acrílica termopolimerizável convencional (Clássico), sendo o GI polimerizado em banho de água quente e o GII pela energia de microondas. Para os grupos GIII, GIV, GV e GVI, utilizou-se resina acrílica autopolimerizável (Jet) e as seguintes técnicas de processamento: GIII) polimerização em condição ambiente (23 l 2oC), GIV) sob pressão de 2kgf/cm2 e água a 40°C, GV) sob a mesma pressão e temperatura a seco e GVI) associação de placa de acetato e polimerização em água a 40°C. Após ensaio de flexão, os dados foram submetidos à análise de variância, complementada pelo teste de Tukey (a = 0,05). Para os valores de microdureza, estes foram submetidos ao teste não paramétrico de Kruskal-Wallis (a = 0,05). Verificou-se que GII e GIII apresentaram, respectivamente, os maiores e menores valores de resistência à flexão em relação aos demais grupos. GI e GII apresentaram valores semelhantes de resistência à flexão (p > 0,05). GIV, V e VI não apresentaram diferença significante entre si (p > 0,05), porém foram estatisticamente superiores ao GIII (p < 0,05). / Abstract: The occlusal splints can be fabricated by many techniques and the acrylic resin is the main material used for this propose. The splints can be easily facture or worn because they are subjected to different kinds of forces during a long period in the oral cavity. The objective of this study was to evaluate the flexural strength and Knoop microhardness of a conventional heat-polymerized and an autopolymerized acrylic resin used to fabricate occlusal splints, varying the processing laboratorial techniques. Sixty specimens were manufactured and divided in 6 groups (GI, GII, GIII, GIV, GV, GVI) according to the type of the resin and the processing technique used. GI and GII were manufactured with conventional heatpolymerized acrylic resin (Clássico). GI was hot-water-bath polymerized and GII was microwave polymerized. GIII, GIV and GV specimens were fabricated using an autopolymerized acrylic resin (Jet). GIII was polymerized in air condition (23 l 2oC), GIV under 2kgf/cm2 pressure and in water at 40°C, and GV under the same pressure and temperature at dry condition. The GVI specimens were manufactured using autopolymerized acrylic resin and acetate sheet, polymerized in water at 40°C. The resin specimens were broken using a 3-point load on a testing machine. A ANOVA and Tukey test were performed to identify significant differences (a = .05). Knoop microhardness values were analyzed with Kruskal-Wallis test (a = .05). GII and GIII showed, respectively, the highest and the lowest significantly values of strength comparing with the other groups. GI and GII, manufactured with conventional heat-polymerized acrylic resin showed similar strength (p > .05). GIV, V e VI showed similar values between them, however they were stronger than GIII (p < .05). GII showed the highest significantly values of microhardness even when compared to GI. / Orientador: Paulo Renato Junqueira Zuim / Coorientador: Débora Barros Barbosa / Banca: Alício Rosalino Garcia / Banca: Osvaldo Luiz Bezzon / Mestre
5

Jaw position during swallowing and the effect of occlusal adjustment upon it a thesis submitted in partial fulfillment ... in restorative dentistry--occlusion ... /

Alem, Ali. January 1976 (has links)
Thesis (M.S.)--University of Michigan, 1976.
6

The relationship between occlusal interferences and graphic tracings of mandibular movement a thesis submitted in partial fulfillment ... in restorative dentistry (crown and bridge) ... /

Aitken, David Lawrence. January 1987 (has links)
Thesis (M.S.)--University of Michigan, 1987.
7

An electromyographic study of orthodontic retention patients before and after occlusal equilibration a thesis submitted in partial fulfillment ... /

Jacob, John T. January 1960 (has links)
Thesis (M.S.)--University of Michigan, 1960.
8

The relationship between occlusal interferences and graphic tracings of mandibular movement a thesis submitted in partial fulfillment ... in restorative dentistry (crown and bridge) ... /

Aitken, David Lawrence. January 1987 (has links)
Thesis (M.S.)--University of Michigan, 1987.
9

Jaw position during swallowing and the effect of occlusal adjustment upon it a thesis submitted in partial fulfillment ... in restorative dentistry--occlusion ... /

Alem, Ali. January 1976 (has links)
Thesis (M.S.)--University of Michigan, 1976.
10

Avaliação da magnitude das interferências oclusais e sua relação com os sinais clínicos de trauma oclusal e sinais e sintomas de desordens temporomandibulares

Mendonça Neto, Tatiany de 26 May 2003 (has links)
Apesar dos conhecimentos atuais mostrarem que a oclusão desempenha um papel relativamente pequeno na etiologia multifatorial das DTMs, publicações recentes demonstraram que algumas alterações oclusais e/ou esqueléticas aumentam o risco do indivíduo apresentar DTM. Dentre estas alterações está a diferença entre RC e MIH no sentido horizontal maior que 4mm. No entanto, ainda não se sabe qual o papel de uma interferência desta magnitude, no sentido vertical, como fator contribuinte para as DTMs. Este estudo verificou a relação de causa e efeito das interferências oclusais no sentido vertical avaliando a relação entre a magnitude da interferência oclusal com a presença de sinais sintomas de trauma oclusal e sinais e sintomas de DTM. Foram avaliados 43 pacientes, independente do gênero e idade, que não poderiam ser desdentados totais, não poderiam apresentar ausência de 5 ou mais unidades oclusais posteriores não substituídas e não poderiam estar em tratamento ortodôntico. O registro da magnitude da interferência oclusal foi feito na região anterior, através da borda incisal do incisivo superior, na face vestibular do incisivo inferior, nas posições de MIH e contato interferente em RC. A diferença em milímetros desta posição determinou a magnitude da interferência oclusal. Os resultados mostraram que as evidências de interferência oclusal estão presentes nos pacientes com e sem sinais e sintomas de DTM e sinais clínicos de trauma oclusal. Concluiu-se que não houve associação entre a magnitude das interferências oclusais e sinais clínicos de trauma oclusal e sinais e sintomas de Desordens Temporomandibulares. / In the present days, occlusion has not been considered important etiologic factor for the development of temporomandibular disorders(TMD) symptoms. However, some features seems to be specially important as contributory factor. Slides from retruded position(RP) to intercuspal position(IP) greater than 4mm are judged as one of those itens. The aim of this study was to evaluated the cause/ effect relationship those interfernces and different clinical signs, including TMD. Sample was constructed by 43 patients with the great interference, recorded in the anterior region in both positions. Patients with 5 or more posterior missing teeth or perform by orthodontic therapy were excluded. There was no relationship or any association between the interferences and clinical signs, including TMD. Author concluded that slides from RP to IP can not be considered a potential risk factor for TMD.

Page generated in 0.0294 seconds