• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 87
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 89
  • 55
  • 24
  • 20
  • 17
  • 17
  • 16
  • 16
  • 16
  • 14
  • 13
  • 13
  • 12
  • 11
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Reprodutibilidade e comparação de diferentes métodos de avaliação de restaurações de resina composta em dentes posteriores

Podestá Rodriguez, Karina January 2007 (has links)
O objetivo deste estudo foi comparar diferentes métodos de avaliação de restaurações de resina composta em dentes posteriores, assim como avaliar a concordância intra-examinador. Cento e trinta e seis restaurações oclusais de resina composta foram avaliadas por um examinador treinado usando os critérios modificados do USPHS para avaliar quatro características das restaurações: integridade marginal, forma anatômica, descoloração marginal e textura superficial. Três métodos diferentes foram estudados: clínico, fotográfico e modelos. A reprodutibilidade intra-examinador foi medida através do teste de Kappa e a comparação de métodos através dos testes não-paramétricos de Fischer e Wilcoxon. Os resultados mostraram que os valores de concordância intra-examinador foram melhores na avaliação de integridade marginal e forma anatômica através de modelos, e os valores foram similares entre a avaliação clínica e fotográfica para integridade marginal e descoloração marginal. A textura superficial apresentou os valores mais baixos de concordância intra-examinador para todos os métodos examinados. O método direto foi significantemente diferente que os métodos indiretos para todas as características avaliadas (p< 0,05). Entretanto, quando os métodos foram avaliados segundo a aceitabilidade clínica considerada pelo USPHS, os métodos não foram diferentes. Os métodos fotográfico e modelos detectaram defeitos que não foram percebidos pelo método clínico na avaliação da integridade marginal e da forma anatômica. As avaliações através de fotografias e modelos foram semelhantes em todas as características avaliadas com exceção da textura superficial (p< 0,05). Todos os métodos mostraram ser inadequados para a avaliação de textura superficial. Houve diferenças significativas entre o método direto e os métodos indiretos. Os métodos indiretos permitiram realizar observações mais detalhadas e críticas. Entretanto, o método clínico mostrou ter capacidade para diferenciar entre restaurações clinicamente aceitáveis e não-aceitáveis. / The aim of this study was to compare different methods for evaluating composite resin restorations in posterior teeth and to evaluate the reproducibility of each method by determining the intraexaminer agreement. One hundred and thirty six occlusal composite resin restorations were evaluated by a trained examiner using modified USPHS criteria to assess four restoration characteristics: marginal integrity, anatomic form, marginal discoloration and surface texture. Three different methods were studied: clinical, photographic and dental cast models. Kappa statistics was used to determine reproducibility and non-parametric Friedman and Wilcoxon tests to compare the methods. The results showed that the best intraexaminer agreement values were obtained for dental cast models evaluations for marginal integrity and anatomic form and were similar between photographic and clinical evaluations for marginal integrity and marginal discoloration. Surface texture showed the lowest degree of intraexaminer agreement with all the methods tested. Direct clinical method and the two indirect methods were significantly different for all the characteristics assessed (p< 0.05). However, when they were evaluated according to USPHS clinical acceptability, the methods did not differ. Photographs and dental cast models methods detected defects that the direct clinical method could not distinguish for marginal integrity and anatomic form. Photographs and dental cast models evaluations were similar for all the characteristics assessed, except for surface texture (p< 0.05). All the methods showed that they are not adequate to evaluate surface texture. There were significant differences between the direct clinical method and the indirect methods for all the composite resin restorations characteristics assessed. The indirect methods allowed more detailed and critical observations. However, the direct clinical method was able to distinguish between clinical acceptable and unacceptable restorations.
52

Estudo dos distúrbios oclusais em posição de intercuspidação máxima com papel articular e palpação dos músculos masseter superficial e temporal anterior numa amostra de portadores de cefaléia crônica do tipo migrânea e voluntários normais

Hüning, Sandra Vargas January 2000 (has links)
Objetivos: Avaliar a freqüência de DNO em pacientes portadores de migrânea e sujeitos normais através do método oclusal visual com papel carbono e palpação muscular nos músculos masseter superficial e temporal anterior, ambos em PIM. Estabelecer a correlação entre o momento de contração destes músculos com seus volumes finais de contração em PIM. Estabelecer correlação entre o método de palpação muscular e o de análise oclusal visual com carbono em PIM. 3. Delineamento: estudo transversal controlado 4. Desfecho (efeito clínico): distúrbio neuro-oclusal (DNO) 5. Fator em estudo: cefaléia crônica do tipo migrânea Metodologia: Foram examinados aleatoriamente 30 pacientes portadores de migrânea do Ambulatório de Cefaléias do HCPA e 55 indivíduos normais, na faixa etária entre 20 e 50 anos. Os exames para verificação da condição neuro-oclusal em PIM foram exame oclusal visual através de papel carbono e palpação muscular em masseter superficial e temporal anterior em PIM. Os DNOs foram divididos em anterior (DNOA) e posterior (DNOP), analisando-se a correlação entre estes parâmetros e os músculos temporal anterior e masseter superficial respectivamente. Resultados: Entre os grupos de migranosos e normais não houve diferença estatisticamente significativa quanto a presença de DNO tanto para a região anterior quanto para a posterior. Os volumes finais de contração dos músculos masseter superficial e temporal anterior mostraram correlação com os seus viii momentos de contração inicial em PIM. Não houve relação entre o local do DNO em PIM com o local de início de cefaléia relatado pelos pacientes. A palpação muscular em PIM do temporal anterior e do masseter superficial apresentou valores de sensibilidade e especificidade que podem chegar a ser aceitáveis para a averiguação da condição oclusal do paciente. Conclusões: Os grupos migrânea e normal apresentam freqüência de DNOs em PIM semelhantes, o que sugere a necessidade de estudos futuros que avaliem aspectos funcionais do SEG que envolvam outras variáveis tais como aspectos da dinâmica mandibular para que a compreensão entre a questão de interrelação entre migrânea e DCOC possa ser abordada de forma mais completa. A utilização conjunta do exame de palpação muscular em masseter superficial e temporal anterior em PIM e do exame oclusal visual com papel carbono pode ser complementar no exame diagnóstico oclusal quando se busca uma abordagem diagnóstico-terapêutica odontológica mais abrangente.
53

Estudo e desenvolvimento de sistema baseado em sensores de pressão aplicados à ortodontia

Crivellaro, Fernando Sacilotto January 2016 (has links)
Este trabalho tem por objetivo o estudo e o desenvolvimento de uma solução de engenharia para o mapeamento e caracterização da oclusão dentária, não somente no âmbito de sua distribuição ao longo da arcada, mas também através da mensuração da intensidade de pressão nos pontos de contato oclusal interarco. Neste sentido, empregaram-se esforços no aprofundamento do conhecimento neste campo da Odontologia, assim como, na elaboração de um sistema experimental que, utilizando sensores de pressão/força resistivos (FSR) específicos para uso odontológico, viabilizou a análise do estado da oclusão, atuando como agente facilitador no diagnóstico de desequilíbrios oclusais. Inicialmente, são apresentados e esclarecidos os principais conceitos da esfera odontológica, os quais são tomados como base para todos os projetos deste trabalho, além da abordagem referente às formas de contato entre os dentes, aos diferentes tipos de oclusão e seus problemas. Em relação ao desenvolvimento do sistema, foram projetadas duas placas de circuito impresso para interface com os sensores e elaborados o firmware de acesso ao hardware, assim como o software de gerenciamento global do sistema. Todos os blocos do circuito de condicionamento foram avaliados e as suas funcionalidades validadas. Do mesmo modo, a caracterização da resposta dos sensores e a sua homogeneidade ao longo da extensão sensível foram analisadas, demonstrando que a resistência elétrica varia de forma análoga em todas as áreas do sensor. Através de ensaios realizados com sujeito envolvido no projeto, estabeleceu-se um comparativo entre a utilização do papel carbono e o sistema desenvolvido, mostrando as vantagens na utilização do segundo, principalmente atreladas à capacidade de avaliação da intensidade dos contatos oclusais. Por fim, ainda se valendo do uso paralelo do papel carbono, foram efetuados ensaios de análise da oclusão em sujeito envolvido no projeto utilizando placa miorrelaxante, possibilitando a utilização da capacidade do sistema desenvolvido para executar ajustes precisos na placa, com a finalidade de manter o balanço de pressões oclusais entre ambos os lados da arcada. / This essay has as objective the study and development of an engineer solution for the dental occlusion mapping and characterization, not only related to the interarch occlusal contact distribution, but also through the pressure magnitude measuring in each. In this sense, was employed effort in the Odontological knowledge increasing and also in the system elaboration allowing the occlusion state evaluation and acting as an easier agent in the occlusion disturbs diagnosing using a specific pressure/force sensing resistor (FSR) for dental use. Initially the main concepts of the Odontological sphere are presented, clarified and took as a base for all the projects in this essay. Besides this, different teeth contacts shapes are shown, as well as the occlusion’s types and its problems. In the system development, two printed circuit boards were designed for sensor interfacing. The hardware access through the firmware was elaborated, even as the global system managing software. All the conditioning circuit blocks and functionalities were evaluated and validated. In the same way, the sensor’s output and its homogeneity through all the sensible extension were evaluated, showing that the sensor’s electric resistance changes in the same form in all the sensor’s areas. In addition, it was showed the advantages of the developed system over the articulation paper through trials with a subject that is part of the project, showing the capacity of the system in the occlusion contacts magnitude evaluation. Ultimately, also in an articulation paper versus the developed system comparison, it was made occlusion analysis trials with subject using a night guard for teeth grinding (bruxism), showing the system capacity of precisely adjust the night guards for pressure balance between the both arch sides.
54

Avaliação clínica e radiográfica de implantes osseointegráveis instalados na mandíbula posterior e submetidos a um protocolo de função oclusal precoce

Pinto, Antonio Vicente de Souza [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T18:43:56Z : No. of bitstreams: 1 pinto_avs_dr_araca.pdf: 1496770 bytes, checksum: c9fd8c4da9c28379a95d5da49951a5df (MD5) / 3i Implant / As vantagens do tratamento do edentulismo total mandibular com implantes osseointegráveis e função oclusal precoce são bem conhecidas. Recentemente, um interesse crescente pelos benefícios dessa modalidade terapêutica envolveu o edentulismo parcial em várias regiões da boca. No entanto, protocolos bem definidos para a mandíbula posterior com função oclusal precoce não foram devidamente testados e aprovados. O objetivo desta investigação foi avaliar a eficácia clínica de um protocolo cirúrgico, protético e radiográfico para o tratamento da mandíbula posterior, com implantes osseointegráveis e função oclusal precoce. Treze pacientes com edentulismo parcial posterior, uni ou bilateral, foram tratados em clínica particular. Cinqüenta e dois implantes foram inseridos em 17 áreas mandibulares, com classes I, II e III de Kennedy. Os implantes utilizados foram MKIII e MKIV, com superfície lisa e foi empregada técnica cirúrgica padronizada para inserção dos implantes. A função oclusal precoce foi obtida com próteses parciais fixas instaladas com uma média de 7 dias da inserção dos implantes.O tempo de observação clínica variou entre 12 e 26 meses, com média de 19 meses. O nível do osso marginal foi determinado com medidas nas imagens digitalizadas de radiografias convencionais padronizadas. A taxa cumulativa de sobrevivência foi de 98,1% e a perda óssea marginal média, nos primeiros seis meses, foi de 1,02mm e 1,07mm para um ano de observação. A taxa da sobrevivência das próteses foi de 100%. Considerando os limites deste estudo, o protocolo testado para tratamento da mandíbula posterior com função oclusal precoce e implantes osseointegráveis parece viável para aplicação clínica em bases rotineiras, No entanto, estudos multicêntricos e a longo prazo devem ser conduzidos para confirmar ou refutar os resultados obtidos. / The early occlusal loading of Osseointegrated implants in mandibular totally edentulous patients have been shown to be a successful and an advantageous approach. Recently, this treatment modality evolved to the treatment of partially edentulous patients. However protocols for treating those cases were neither tested nor approved. The objective of this investigation was to evaluate the clinical efficacy of a surgical, a prosthetic and a radiographic protocol idealized for the treatment of the posterior mandible with early occlusaly loaded osseointegrated implants. Thirteen partially edentulous patients in the posterior mandibleunilaterally or bilaterally, were treated in a private practice setting. Fifty two fixtures were placed in seventeen mandibular areas class I, II and III accordingly to Kennedy’s classification. Machined MKIII and MKIV implants were placed utilizing standardized surgical technique. Early loading conditions were obtained with the placement of fixed partial dentures installed in average seven days after fixtures installation. The clinical observation time varied between 12 and 26 months with an average of 19 months. The marginal bone levels were determined from digital images derived from standardized conventional radiographs. A mean marginal bone loss of 1.02mm was noted in the first six months of observation and a mean marginal bone loss of 1.07 mm after 12 months under the evaluated conditions. The cumulative survival rate of 98.1% and 100 % were found for implants and prostheses respectively. Within the limits of this study, it can be concluded that the tested protocol for the treatment of the posterior mandible with osseointegrated implants under early occlusal loading condition seemed to be a viable clinical alternative for routine application. Nevertheless, additional studies including a multicenter design and longer evaluation periods are necessary to substantiate these findings.
55

Reprodutibilidade e comparação de diferentes métodos de avaliação de restaurações de resina composta em dentes posteriores

Podestá Rodriguez, Karina January 2007 (has links)
O objetivo deste estudo foi comparar diferentes métodos de avaliação de restaurações de resina composta em dentes posteriores, assim como avaliar a concordância intra-examinador. Cento e trinta e seis restaurações oclusais de resina composta foram avaliadas por um examinador treinado usando os critérios modificados do USPHS para avaliar quatro características das restaurações: integridade marginal, forma anatômica, descoloração marginal e textura superficial. Três métodos diferentes foram estudados: clínico, fotográfico e modelos. A reprodutibilidade intra-examinador foi medida através do teste de Kappa e a comparação de métodos através dos testes não-paramétricos de Fischer e Wilcoxon. Os resultados mostraram que os valores de concordância intra-examinador foram melhores na avaliação de integridade marginal e forma anatômica através de modelos, e os valores foram similares entre a avaliação clínica e fotográfica para integridade marginal e descoloração marginal. A textura superficial apresentou os valores mais baixos de concordância intra-examinador para todos os métodos examinados. O método direto foi significantemente diferente que os métodos indiretos para todas as características avaliadas (p< 0,05). Entretanto, quando os métodos foram avaliados segundo a aceitabilidade clínica considerada pelo USPHS, os métodos não foram diferentes. Os métodos fotográfico e modelos detectaram defeitos que não foram percebidos pelo método clínico na avaliação da integridade marginal e da forma anatômica. As avaliações através de fotografias e modelos foram semelhantes em todas as características avaliadas com exceção da textura superficial (p< 0,05). Todos os métodos mostraram ser inadequados para a avaliação de textura superficial. Houve diferenças significativas entre o método direto e os métodos indiretos. Os métodos indiretos permitiram realizar observações mais detalhadas e críticas. Entretanto, o método clínico mostrou ter capacidade para diferenciar entre restaurações clinicamente aceitáveis e não-aceitáveis. / The aim of this study was to compare different methods for evaluating composite resin restorations in posterior teeth and to evaluate the reproducibility of each method by determining the intraexaminer agreement. One hundred and thirty six occlusal composite resin restorations were evaluated by a trained examiner using modified USPHS criteria to assess four restoration characteristics: marginal integrity, anatomic form, marginal discoloration and surface texture. Three different methods were studied: clinical, photographic and dental cast models. Kappa statistics was used to determine reproducibility and non-parametric Friedman and Wilcoxon tests to compare the methods. The results showed that the best intraexaminer agreement values were obtained for dental cast models evaluations for marginal integrity and anatomic form and were similar between photographic and clinical evaluations for marginal integrity and marginal discoloration. Surface texture showed the lowest degree of intraexaminer agreement with all the methods tested. Direct clinical method and the two indirect methods were significantly different for all the characteristics assessed (p< 0.05). However, when they were evaluated according to USPHS clinical acceptability, the methods did not differ. Photographs and dental cast models methods detected defects that the direct clinical method could not distinguish for marginal integrity and anatomic form. Photographs and dental cast models evaluations were similar for all the characteristics assessed, except for surface texture (p< 0.05). All the methods showed that they are not adequate to evaluate surface texture. There were significant differences between the direct clinical method and the indirect methods for all the composite resin restorations characteristics assessed. The indirect methods allowed more detailed and critical observations. However, the direct clinical method was able to distinguish between clinical acceptable and unacceptable restorations.
56

Estudo dos distúrbios oclusais em posição de intercuspidação máxima com papel articular e palpação dos músculos masseter superficial e temporal anterior numa amostra de portadores de cefaléia crônica do tipo migrânea e voluntários normais

Hüning, Sandra Vargas January 2000 (has links)
Objetivos: Avaliar a freqüência de DNO em pacientes portadores de migrânea e sujeitos normais através do método oclusal visual com papel carbono e palpação muscular nos músculos masseter superficial e temporal anterior, ambos em PIM. Estabelecer a correlação entre o momento de contração destes músculos com seus volumes finais de contração em PIM. Estabelecer correlação entre o método de palpação muscular e o de análise oclusal visual com carbono em PIM. 3. Delineamento: estudo transversal controlado 4. Desfecho (efeito clínico): distúrbio neuro-oclusal (DNO) 5. Fator em estudo: cefaléia crônica do tipo migrânea Metodologia: Foram examinados aleatoriamente 30 pacientes portadores de migrânea do Ambulatório de Cefaléias do HCPA e 55 indivíduos normais, na faixa etária entre 20 e 50 anos. Os exames para verificação da condição neuro-oclusal em PIM foram exame oclusal visual através de papel carbono e palpação muscular em masseter superficial e temporal anterior em PIM. Os DNOs foram divididos em anterior (DNOA) e posterior (DNOP), analisando-se a correlação entre estes parâmetros e os músculos temporal anterior e masseter superficial respectivamente. Resultados: Entre os grupos de migranosos e normais não houve diferença estatisticamente significativa quanto a presença de DNO tanto para a região anterior quanto para a posterior. Os volumes finais de contração dos músculos masseter superficial e temporal anterior mostraram correlação com os seus viii momentos de contração inicial em PIM. Não houve relação entre o local do DNO em PIM com o local de início de cefaléia relatado pelos pacientes. A palpação muscular em PIM do temporal anterior e do masseter superficial apresentou valores de sensibilidade e especificidade que podem chegar a ser aceitáveis para a averiguação da condição oclusal do paciente. Conclusões: Os grupos migrânea e normal apresentam freqüência de DNOs em PIM semelhantes, o que sugere a necessidade de estudos futuros que avaliem aspectos funcionais do SEG que envolvam outras variáveis tais como aspectos da dinâmica mandibular para que a compreensão entre a questão de interrelação entre migrânea e DCOC possa ser abordada de forma mais completa. A utilização conjunta do exame de palpação muscular em masseter superficial e temporal anterior em PIM e do exame oclusal visual com papel carbono pode ser complementar no exame diagnóstico oclusal quando se busca uma abordagem diagnóstico-terapêutica odontológica mais abrangente.
57

Avaliação da capacidade de identificação de prematuridades oclusais, por meio cortes paraxiais obtidos de tomografias computadorizadas de feixe cônico (Cone Beam)

Machado, Naila Aparecida de Godoi 23 February 2010 (has links)
The objective of this study was to evaluate the ability to identify occlusal prematurity, by cutting the paraxial CT cone beam, comparing the opinion of these images, provided by professionals in different specialities, with clinical examination obtained from strips of carbon paper. Sixteen young asymptomatic patients underwent an initial clinical examination and then were made appliance desprogramming individual (Lucia JIG). Through manipulation and marking interocclusal jaw with carbon film (Accufilm) identified clinically premature contact Centric Relation (CR) of each patient. Later these devices were set in the position of centric contact and used during the CT scans so that they could obtain tomographic images in the position of centric relation. After processing the images, these were analyzed for thirty professionals from different areas and compared the results obtained by the analysis of imaging and analysis of clinical markers. The data were statistically analyzed by analysis of variance ANOVA and Scott-Knott. From the evaluation of the ability to identify occlusal prematurity through cuts of paraxial CT cone beam, we can conclude that there was no statistically significant difference between the views of professionals with clinical examination carried out with carbon paper. Comparing the opinions expressed by professionals in the areas of occlusion, Radiology and General Clinicians, notes that there was no statistically significant differences. Regarding the time of his profession, the group with less time since graduation had the lowest rate of agreement among the analysis of imaging and clinical analysis with carbon paper. / O objetivo deste estudo foi avaliar a capacidade de identificação de prematuridades oclusais, por meio de cortes paraxiais de tomografias computadorizadas de feixe cônico, confrontando o parecer destas imagens, estabelecido por profissionais de diferentes áreas odontológicas, com a análise clínica obtida por meio de marcações com papel carbono. Dezesseis pacientes jovens assintomáticos foram submetidos a um exame clínico inicial e em seguida foram confeccionados dispositivos desprogramadores individuais ( JIG de Lucia ). Mediante manipulação mandibular e marcação interoclusal com papel carbono (Accufilm) identificou-se clinicamente o contato prematuro em Relação Cêntrica (RC) de cada paciente. Posteriormente estes dispositivos foram ajustados na posição de contato cêntrico e utilizados durante os exames tomográficos para que se pudessem obter imagens tomográficas na posição de Relação Cêntrica. Após o processamento das imagens, estas foram analisadas por trinta profissionais das áreas de Oclusão, Radiologia e Clínico Geral (n=10 para cada área) e compararam-se os resultados obtidos pela análise das imagens tomográficas e pela análise clínica por marcações. Os dados obtidos foram analisados estatisticamente pela Análise de Variância ANOVA e pósteste de Scott-Knott (p <0,05). A partir da avaliação da capacidade de identificação de prematuridades oclusais por meio de cortes paraxiais de tomografias computadorizadas de feixe cônico, pode-se concluir que não houve diferenças estatisticamente significantes entre os pareceres dos profissionais com a análise clínica realizada com papel carbono. Ao comparar os pareceres emitidos pelos profissionais das áreas de Oclusão, Radiologia e Clínica Geral, constata-se que não houve diferenças estatisticamente significantes. Em relação ao tempo de exercício profissional, o grupo com menor tempo de formado apresentou o menor índice de concordância entre os pareceres da análise das imagens tomográficas e a análise clínica com papel carbono. / Mestre em Odontologia
58

Estudo e desenvolvimento de sistema baseado em sensores de pressão aplicados à ortodontia

Crivellaro, Fernando Sacilotto January 2016 (has links)
Este trabalho tem por objetivo o estudo e o desenvolvimento de uma solução de engenharia para o mapeamento e caracterização da oclusão dentária, não somente no âmbito de sua distribuição ao longo da arcada, mas também através da mensuração da intensidade de pressão nos pontos de contato oclusal interarco. Neste sentido, empregaram-se esforços no aprofundamento do conhecimento neste campo da Odontologia, assim como, na elaboração de um sistema experimental que, utilizando sensores de pressão/força resistivos (FSR) específicos para uso odontológico, viabilizou a análise do estado da oclusão, atuando como agente facilitador no diagnóstico de desequilíbrios oclusais. Inicialmente, são apresentados e esclarecidos os principais conceitos da esfera odontológica, os quais são tomados como base para todos os projetos deste trabalho, além da abordagem referente às formas de contato entre os dentes, aos diferentes tipos de oclusão e seus problemas. Em relação ao desenvolvimento do sistema, foram projetadas duas placas de circuito impresso para interface com os sensores e elaborados o firmware de acesso ao hardware, assim como o software de gerenciamento global do sistema. Todos os blocos do circuito de condicionamento foram avaliados e as suas funcionalidades validadas. Do mesmo modo, a caracterização da resposta dos sensores e a sua homogeneidade ao longo da extensão sensível foram analisadas, demonstrando que a resistência elétrica varia de forma análoga em todas as áreas do sensor. Através de ensaios realizados com sujeito envolvido no projeto, estabeleceu-se um comparativo entre a utilização do papel carbono e o sistema desenvolvido, mostrando as vantagens na utilização do segundo, principalmente atreladas à capacidade de avaliação da intensidade dos contatos oclusais. Por fim, ainda se valendo do uso paralelo do papel carbono, foram efetuados ensaios de análise da oclusão em sujeito envolvido no projeto utilizando placa miorrelaxante, possibilitando a utilização da capacidade do sistema desenvolvido para executar ajustes precisos na placa, com a finalidade de manter o balanço de pressões oclusais entre ambos os lados da arcada. / This essay has as objective the study and development of an engineer solution for the dental occlusion mapping and characterization, not only related to the interarch occlusal contact distribution, but also through the pressure magnitude measuring in each. In this sense, was employed effort in the Odontological knowledge increasing and also in the system elaboration allowing the occlusion state evaluation and acting as an easier agent in the occlusion disturbs diagnosing using a specific pressure/force sensing resistor (FSR) for dental use. Initially the main concepts of the Odontological sphere are presented, clarified and took as a base for all the projects in this essay. Besides this, different teeth contacts shapes are shown, as well as the occlusion’s types and its problems. In the system development, two printed circuit boards were designed for sensor interfacing. The hardware access through the firmware was elaborated, even as the global system managing software. All the conditioning circuit blocks and functionalities were evaluated and validated. In the same way, the sensor’s output and its homogeneity through all the sensible extension were evaluated, showing that the sensor’s electric resistance changes in the same form in all the sensor’s areas. In addition, it was showed the advantages of the developed system over the articulation paper through trials with a subject that is part of the project, showing the capacity of the system in the occlusion contacts magnitude evaluation. Ultimately, also in an articulation paper versus the developed system comparison, it was made occlusion analysis trials with subject using a night guard for teeth grinding (bruxism), showing the system capacity of precisely adjust the night guards for pressure balance between the both arch sides.
59

Reprodutibilidade e comparação de diferentes métodos de avaliação de restaurações de resina composta em dentes posteriores

Podestá Rodriguez, Karina January 2007 (has links)
O objetivo deste estudo foi comparar diferentes métodos de avaliação de restaurações de resina composta em dentes posteriores, assim como avaliar a concordância intra-examinador. Cento e trinta e seis restaurações oclusais de resina composta foram avaliadas por um examinador treinado usando os critérios modificados do USPHS para avaliar quatro características das restaurações: integridade marginal, forma anatômica, descoloração marginal e textura superficial. Três métodos diferentes foram estudados: clínico, fotográfico e modelos. A reprodutibilidade intra-examinador foi medida através do teste de Kappa e a comparação de métodos através dos testes não-paramétricos de Fischer e Wilcoxon. Os resultados mostraram que os valores de concordância intra-examinador foram melhores na avaliação de integridade marginal e forma anatômica através de modelos, e os valores foram similares entre a avaliação clínica e fotográfica para integridade marginal e descoloração marginal. A textura superficial apresentou os valores mais baixos de concordância intra-examinador para todos os métodos examinados. O método direto foi significantemente diferente que os métodos indiretos para todas as características avaliadas (p< 0,05). Entretanto, quando os métodos foram avaliados segundo a aceitabilidade clínica considerada pelo USPHS, os métodos não foram diferentes. Os métodos fotográfico e modelos detectaram defeitos que não foram percebidos pelo método clínico na avaliação da integridade marginal e da forma anatômica. As avaliações através de fotografias e modelos foram semelhantes em todas as características avaliadas com exceção da textura superficial (p< 0,05). Todos os métodos mostraram ser inadequados para a avaliação de textura superficial. Houve diferenças significativas entre o método direto e os métodos indiretos. Os métodos indiretos permitiram realizar observações mais detalhadas e críticas. Entretanto, o método clínico mostrou ter capacidade para diferenciar entre restaurações clinicamente aceitáveis e não-aceitáveis. / The aim of this study was to compare different methods for evaluating composite resin restorations in posterior teeth and to evaluate the reproducibility of each method by determining the intraexaminer agreement. One hundred and thirty six occlusal composite resin restorations were evaluated by a trained examiner using modified USPHS criteria to assess four restoration characteristics: marginal integrity, anatomic form, marginal discoloration and surface texture. Three different methods were studied: clinical, photographic and dental cast models. Kappa statistics was used to determine reproducibility and non-parametric Friedman and Wilcoxon tests to compare the methods. The results showed that the best intraexaminer agreement values were obtained for dental cast models evaluations for marginal integrity and anatomic form and were similar between photographic and clinical evaluations for marginal integrity and marginal discoloration. Surface texture showed the lowest degree of intraexaminer agreement with all the methods tested. Direct clinical method and the two indirect methods were significantly different for all the characteristics assessed (p< 0.05). However, when they were evaluated according to USPHS clinical acceptability, the methods did not differ. Photographs and dental cast models methods detected defects that the direct clinical method could not distinguish for marginal integrity and anatomic form. Photographs and dental cast models evaluations were similar for all the characteristics assessed, except for surface texture (p< 0.05). All the methods showed that they are not adequate to evaluate surface texture. There were significant differences between the direct clinical method and the indirect methods for all the composite resin restorations characteristics assessed. The indirect methods allowed more detailed and critical observations. However, the direct clinical method was able to distinguish between clinical acceptable and unacceptable restorations.
60

Estudo dos distúrbios oclusais em posição de intercuspidação máxima com papel articular e palpação dos músculos masseter superficial e temporal anterior numa amostra de portadores de cefaléia crônica do tipo migrânea e voluntários normais

Hüning, Sandra Vargas January 2000 (has links)
Objetivos: Avaliar a freqüência de DNO em pacientes portadores de migrânea e sujeitos normais através do método oclusal visual com papel carbono e palpação muscular nos músculos masseter superficial e temporal anterior, ambos em PIM. Estabelecer a correlação entre o momento de contração destes músculos com seus volumes finais de contração em PIM. Estabelecer correlação entre o método de palpação muscular e o de análise oclusal visual com carbono em PIM. 3. Delineamento: estudo transversal controlado 4. Desfecho (efeito clínico): distúrbio neuro-oclusal (DNO) 5. Fator em estudo: cefaléia crônica do tipo migrânea Metodologia: Foram examinados aleatoriamente 30 pacientes portadores de migrânea do Ambulatório de Cefaléias do HCPA e 55 indivíduos normais, na faixa etária entre 20 e 50 anos. Os exames para verificação da condição neuro-oclusal em PIM foram exame oclusal visual através de papel carbono e palpação muscular em masseter superficial e temporal anterior em PIM. Os DNOs foram divididos em anterior (DNOA) e posterior (DNOP), analisando-se a correlação entre estes parâmetros e os músculos temporal anterior e masseter superficial respectivamente. Resultados: Entre os grupos de migranosos e normais não houve diferença estatisticamente significativa quanto a presença de DNO tanto para a região anterior quanto para a posterior. Os volumes finais de contração dos músculos masseter superficial e temporal anterior mostraram correlação com os seus viii momentos de contração inicial em PIM. Não houve relação entre o local do DNO em PIM com o local de início de cefaléia relatado pelos pacientes. A palpação muscular em PIM do temporal anterior e do masseter superficial apresentou valores de sensibilidade e especificidade que podem chegar a ser aceitáveis para a averiguação da condição oclusal do paciente. Conclusões: Os grupos migrânea e normal apresentam freqüência de DNOs em PIM semelhantes, o que sugere a necessidade de estudos futuros que avaliem aspectos funcionais do SEG que envolvam outras variáveis tais como aspectos da dinâmica mandibular para que a compreensão entre a questão de interrelação entre migrânea e DCOC possa ser abordada de forma mais completa. A utilização conjunta do exame de palpação muscular em masseter superficial e temporal anterior em PIM e do exame oclusal visual com papel carbono pode ser complementar no exame diagnóstico oclusal quando se busca uma abordagem diagnóstico-terapêutica odontológica mais abrangente.

Page generated in 0.0534 seconds