• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 188
  • 67
  • 32
  • 17
  • 14
  • 8
  • 5
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 388
  • 388
  • 374
  • 97
  • 69
  • 66
  • 65
  • 64
  • 62
  • 55
  • 44
  • 40
  • 37
  • 36
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

Comparison of Normal- and High-Tension Glaucoma: Nerve Fiber Layer and Optic Nerve Head Damage

Häntzschel, Janek, Terai, Naim, Furashova, Olga, Pillunat, Karin, Pillunat, Lutz E. 19 May 2020 (has links)
Purpose: The aim of this study was to investigate differences in the nerve fiber layer and glaucoma-induced structural optic nerve head (ONH) damage in patients with normal- (NTG) and high-tension (HTG) glaucoma. Methods: In this retrospective pair-matched comparative study, 22 NTG and 22 HTG eyes were matched according to the same glaucomatous damage based on rim volume, rim area and disk size, as measured by Heidelberg retinal tomography (HRT III). Visual fields (VF) were assessed by Humphrey perimetry, and nerve fiber layer thickness was determined both by scanning laser polarimetry (GDxVCC) and spectral-domain optical coherence tomography (SD-OCT). Comparisons of all measured parameters were made between NTG and HTG groups. Results: Based on HRT results, both NTG and HTG eyes displayed comparable structural damage to the ONH (NTG/HTG, mean: disk area, 2.30/2.31 mm 2 , p = 0.942; rim area, 1.02/0.86 mm 2 , p = 0.082; rim volume, 0.19/0.17 mm 3 , p = 0.398). NTG eyes had significantly less VF damage than HTG eyes (NTG/HTG, mean deviation: –4.23/–12.12 dB, p = 0.002; pattern standard deviation: 5.39/8.23 dB, p = 0.022). The inferior nerve fiber layer of NTG patients was significantly thicker than that of HTG patients (NTG/HTG, mean: GDx inferior: 53.5/46.3 μm, p = 0.046). SD-OCT revealed a significantly thicker nerve fiber in NTG compared with HTG patients in all quadrants (NTG/HTG, total mean: 72.72/58.45 μm, p = 0.002). Conclusion: At comparable glaucomatous stages, nerve fiber loss was more advanced in HTG patients compared with NTG patients.
352

Detection of carious lesions utilizing depolarization imaging by polarization sensitive optical coherence tomography

Golde, Jonas, Tetschke, Florian, Walther, Julia, Rosenauer, Tobias, Hempel, Franz, Hannig, Christian, Koch, Edmund, Kirsten, Lars 27 August 2020 (has links)
As dental caries is one of the most common diseases, the early and noninvasive detection of carious lesions plays an important role in public health care. Optical coherence tomography (OCT) with its ability of depth-resolved, high-resolution, noninvasive, fast imaging has been previously recognized as a promising tool in dentistry. Additionally, polarization sensitive imaging provides quantitative measures on the birefringent tissue properties and can be utilized for imaging dental tissue, especially enamel and dentin. By imaging three exemplary tooth samples ex vivo with proximal white spot, brown spot, and cavity, we show that the combination of polarization sensitive OCT and the degree of polarization uniformity (DOPU) algorithm is a promising approach for the detection of proximal carious lesions due to the depolarization contrast of demineralized tissue. Furthermore, we investigate different sizes of the DOPU evaluation kernel on the resulting contrast and conclude a suitable value for this application. We propose that DOPU provides an easy to interpret image representation and appropriate contrast for possible future screening applications in early caries diagnostics.
353

In vivo imaging in the oral cavity by endoscopic optical coherence tomography

Walther, Julia, Schnabel, Christian, Tetschke, Florian, Rosenauer, Tobias, Golde, Jonas, Ebert, Nadja, Baumann, Michael, Hannig, Christian, Koch, Edmund 01 September 2020 (has links)
The common way to diagnose hard and soft tissue irregularities in the oral cavity is initially the visual inspection by an experienced dentist followed by further medical examinations, such as radiological imaging and/or histopathological investigation. For the diagnosis of oral hard and soft tissues, the detection of early transformations is mostly hampered by poor visual access, low specificity of the diagnosis techniques, and/or limited feasibility of frequent screenings. Therefore, optical noninvasive diagnosis of oral tissue is promising to improve the accuracy of oral screening. Considering this demand, a rigid handheld endoscopic scanner was developed for optical coherence tomography (OCT). The novelty is the usage of a commercially near-infrared endoscope with fitting optics in combination with an established spectral-domain OCT system of our workgroup. By reaching a high spatial resolution, in vivo images of anterior and especially posterior dental and mucosal tissues were obtained from the oral cavity of two volunteers. The convincing image quality of the endoscopic OCT device is particularly obvious for the imaging of different regions of the human soft palate with highly scattering fibrous layer and capillary network within the lamina propria.
354

Multimodální registrace obrazů sítnice / Multimodal retinal image registration

Štohanzlová, Petra January 2011 (has links)
This work deals with possibilities of registration of retinal images from different mo-dalities, concretely optical coherence tomography (OCT), scanning laser ophthalmoscopy (SLO) and fundus camera. In first stage is the interest focused on registration of SLO and fundus images, which will serve to determine area of interest for consecutive registration of OCT data. The final stage is finding correct location of OCT B-scans in fundus image. On the basis of the studied methods of registration was chosen method making use of computation of correlation coefficient for both cases. For finding optimal parameters of registration is used searching through whole space of parameters. In partial stages of the work was created algorithm for alignment of B-scans followed by detection of blood vessels and also simple algorithm for detection of blood vessels from fundus image. For more transparent registration the graphical user interface was created, which allows loading input images and displaying the result in several possible forms.
355

Analýza vrstvy nervových vláken pro účely diagnostiky glaukomu / Analysis of retinal nerve fiber layer for diagnosis of glaucoma

Vodáková, Martina January 2013 (has links)
The master thesis is focused on creating a methodology for quantification of the nerve fiber layer on photographs of the retina. The introductory part of the text presents a medical motivation of the thesis and mentions several studies dealing with this issue. Furthermore, the work describes available textural features and compares their ability to quantify the thickness of the nerve fiber layer. Based on the described knowledge, the methodology to make different regression models enabling prediction of the retinal nerve fiber layer thickness was developed. Then, the methodology was tested on the available image dataset. The results showed, that the outputs of regression models achieve a high correlation between the predicted output and the retinal nerve fiber layer thickness measured by optical coherence tomography. The conclusion discusses an usability of the applied solution.
356

Prostorové dělení optických svazků / Spatial Division of Optical Beams

Hampl, Martin January 2009 (has links)
The dissertation thesis deals with a free space optical links, especially is focused directly to the transmission optical beams. The influence of environmental conditions like atmospheric turbulence, buildings movement and vibration is described. As a possibility to reduce these undesirable influences, the generation of the transmission beam by the help of the two-mode optical fiber is proposed. A possibility to drive the shape of the resulting transmission beam by means of the change of power ration of individual modes in fiber is described. The coherence features of the proposed beam are analyzed considering the possibility to reduce the influence of atmospheric turbulence. In the thesis there are introduced beam quality parameters that enable to evaluate the quality of the optical beam for the free space optical link. These parameters give the relationship between the shape of the optical beam and the power balance of the optical link and the statistical evaluation of the optical link.
357

Výzkum sklivce a vitreoretinálního rozhraní u mikrovaskulárních chorob sítnice se zaměřením na oční komplikace diabetes mellitus. / Research of vitreous and vitreoretinal interface in microvascular retinal disorders focussed on eye complications of diabetes mellitus

Křížová, Libuše January 2016 (has links)
In this work I present conclusions of clinical-laboratory research focused on the patients with diabetic macular edema (DME). We performed biochemical and immunochemical analyses of vitreous samples that were collected during the pars plana vitrectomy. Moreover, at patients with non-proliferative diabetic retinopathy (NPDR) we assessed morphological characteristics of DME using optical coherence tomography (OCT). According to our findings, the vitreous and serum concentrations of uric acid and glucose were significantly higher in patients with diabetic retinopathy and DME compared to controls. Also total ratio (serum/ vitreous concentration) of uric acid and glucose was in diabetics significantly higher than in controls. The most important determinant of increasing concentration of both uric acid and glucose in the vitreous was the grade of diabetic retinopathy. Moreover, we demonstrated significant correlation between vitreous concentration of uric acid and concentration of the vascular endothelial growth factor (VEGF) in patients with DME and NPDR. We found further, that the volume of the macula (cube volume - CV) computed with the software of Cirrus HD-OCT correlates in diabetics significantly with the vitreous VEGF concentration, but not with uric acid. This OCT parameter could be used to...
358

Výzkum sklivce a vitreoretinálního rozhraní u mikrovaskulárních chorob sítnice se zaměřením na oční komplikace diabetes mellitus. / Research of vitreous and vitreoretinal interface in microvascular retinal disorders focussed on eye complications of diabetes mellitus

Křížová, Libuše January 2016 (has links)
In this work I present conclusions of clinical-laboratory research focused on the patients with diabetic macular edema (DME). We performed biochemical and immunochemical analyses of vitreous samples that were collected during the pars plana vitrectomy. Moreover, at patients with non-proliferative diabetic retinopathy (NPDR) we assessed morphological characteristics of DME using optical coherence tomography (OCT). According to our findings, the vitreous and serum concentrations of uric acid and glucose were significantly higher in patients with diabetic retinopathy and DME compared to controls. Also total ratio (serum/ vitreous concentration) of uric acid and glucose was in diabetics significantly higher than in controls. The most important determinant of increasing concentration of both uric acid and glucose in the vitreous was the grade of diabetic retinopathy. Moreover, we demonstrated significant correlation between vitreous concentration of uric acid and concentration of the vascular endothelial growth factor (VEGF) in patients with DME and NPDR. We found further, that the volume of the macula (cube volume - CV) computed with the software of Cirrus HD-OCT correlates in diabetics significantly with the vitreous VEGF concentration, but not with uric acid. This OCT parameter could be used to...
359

Quantitative Analyse retinaler Veränderungen bei nichtglaukomatösen Optikusatrophien mit Hilfe der Optischen Kohärenztomographie

Kühn, Elisabeth 28 April 2011 (has links)
Nichtglaukomatöse Optikusatrophien führen nicht nur zu einer Verminderung der Dicke der retinalen Nervenfaserschicht (RNFL) sondern auch zu einer Reduktion des Makulavolumens. In dieser Arbeit wurde mit Hilfe der optischen Kohärenztomographie (OCT) untersucht, welche Schichten der Makula von Dickenveränderungen als Folge einer Optikusatrophie betroffen sind. Es wurden 27 Patienten mit nichtglaukomatösen Optikusatrophien unterschiedlicher Ätiologie (postneuritische, hereditäre und traumatische Atrophien) und 21 augengesunde Kontrollpersonen untersucht. OCT-Scans der RNFL und der Makula wurden mit Hilfe des Stratus OCT 3000 (Carl Zeiss Meditec) durchgeführt. Die axialen Reflektivitätsprofile der radialen Scans wurden aus den exportierten JPEG-Bildern an zwölf Punkten in je 1,5mm Entfernung von der Foveola vermessen und gemittelt. Das charakteristische Reflektivitätsprofil mit fünf Intensitätsmaxima und vier Intensitätsminima wurde der Lokalisation der einzelnen Makulaschichten zugeordnet. Die von nichtglaukomatöser Optikusatrophie betroffenen Augen wiesen im Vergleich zu den Augen der augengesunden Normalpersonen signifikant (p<0,05) reduzierte RNFL-Dicken (um 35,5% reduziert) und Makulavolumen-Werte (um 11,8% reduziert) auf. Bei allen untersuchten Formen der Optikusatrophie waren nicht nur die makuläre Nervenfaserschicht (MNFL) sondern alle inneren Schichten der Makula verdünnt. Die mittlere Reduktion betrug 21,2% für die MNFL, 39,7% für die Ganglienzellschicht, 33,2% für die innere plexiforme Schicht und 9,4% für die innere Körnerzellschicht im Vergleich zu den Werten der Normalpersonen. Veränderungen der äußeren Netzhautschichten traten nur bei den posttraumatischen Atrophien auf. Eine Beurteilung der Dicke aller einzelnen Netzhautschichten aus OCT-Scans ist mit Hilfe geräteintegrierter Software bisher noch nicht möglich. Die quantitative Analyse der axialen Reflektivitätsprofile aus exportierten OCT-Bildern stellt eine geeignete Methode zur Beschreibung des Verlaufs und der Lokalisation von Makulaveränderungen bei Optikusatrophien verschiedener Genese dar.
360

3D handheld endoscope for optical coherence tomography of the human oral mucosa in vivo

Walther, Julia, Schnabel, Christian, Ebert, Nadja, Baumann, Michael, Koch, Edmund 06 September 2019 (has links)
The early non-invasive diagnosis of epithelial tissue alterations in daily clinical routine is still challenging. Since optical coherence tomography (OCT) shows the potential to differentiate between benign and malignant tissue of primal endothelium, OCT could be beneficial for the early diagnosis of malignancies in routine health checks. In this research, a new handheld endoscopic scanning unit was designed and connected to a spectral domain OCT system of our workgroup for the in vivo imaging of the human oral mucosa.

Page generated in 0.057 seconds