Spelling suggestions: "subject:"orthodontic anchored procedures. eng"" "subject:"orthodontic anchor procedures. eng""
1 |
Avaliação da resistência ao arrancamento de mini-implantes ortodônticos : estudo laboratorial /Gouvêa, Carla Corrêa Mendes. January 2011 (has links)
Orientador: Eduardo César Almada Santos / Coorientador: Paulo Henrique dos Santos / Banca: Francisco Antonio Bertoz / Banca: José Fernando Castanha Henriques / Resumo: Objetivo: comparar, por meio do teste de arrancamento, a estabilidade primária de mini-implantes com diâmetro e comprimento diferentes inseridos em osso artificial. Material e método: foram utilizados 80 mini-implantes da marca SIN (Sistema de Implante) com 1mm de perfil transmucoso e divididos em 4 grupos: grupo I - mini-implantes de 1,4 mm de diâmetro e 6 mm de comprimento ; o grupo II - mini-implantes de 1,4 mm de diâmetro e 8 mm de comprimento; o grupo III - mini-implantes de 1,6 mm de diâmetro e 6 mm de comprimento; grupo IV - mini-implantes de 1,6 mm de diâmetro e 8 mm de comprimento. Os mini-implantes foram inseridos em bloco de osso artificial Sawbones (SAWBONES Pacific Research Laboratories) e submetidos ao teste de arrancamento na máquina de ensaio universal - EMIC. Resultados: os valores médios de força de arrancamento dos mini-implantes oscilaram entre 621.995N a 738.220N. A Análise de Variância mostrou que houve diferença estatisticamente significante entre os grupos (p<0.05). Na comparação entre os grupos houve igualdade entre os grupos I e III. Todas as demais comparações foram estatisticamente diferentes. Conclusões: em relação à estabilidade primária, constatou-se que os grupos I e III foram iguais, enquanto que, todos os demais apresentaram diferença na estabilidade / Abstract: Objective: to compare, by means of the pullout test, the primary stability of mini-implants with different diameter and length placed in artificial bone. Method: 80 mini-implants Sin (Implant System) with 1mm transmucosal profile and divided into four groups: Group I - mini-implants with diameter of 1.4mm and 6 mm of long; Group II - mini-implants with diameter of 1.4mm and 8 mm long; Group III - mini-implants with diameter of 1.6mm and 6 mm of long; Group IV - mini-implants with a diameter of 1.6mm and 8 mm of long. Mini-implants were inserted in block artificial bone Sawbones (Sawbones Pacific Research Laboratories) and tested in pullout universal testing machine - EMIC. Results: the mean pullout strength of mini-implants ranged from 621.995 to 738,220 N. Analysis of Variance showed that there was a statistically significant difference between the groups (p <0.05). Comparing the groups were only equality between groups I (mini-implants 1.4 Ø x 6 mm) and III (mini-implants Ø 1.6 x 6mm). All other comparisons are statistically different. Conclusions: relative primary stability, it was found that the groups I and III were similar, whereas all others show differences in stability / Mestre
|
2 |
Minimplante e botão lingual como ancoragem para retração inicial de caninos superiores : estudo prospectivo /Arantes, Flávia de Moraes. January 2009 (has links)
Orientador: Eduardo César Almada Santos / Banca: Francisco Antônio Bertoz / Banca: Júlio de Araújo Gurgel / Banca: José Rino Neto / Banca: Marcos Roberto de Freitas / Resumo: A preocupação com a ancoragem é um dos principais fatores a serem considerados no planejamento de um tratamento ortodôntico. Entendem-se como ancoragem os procedimentos intra e extrabucal em que um ou mais dentes ou dispositivos ortodônticos são utilizados como apoio para movimentar outros dentes. A utilização mais frequente dos implantes decorre de uma menor colaboração do paciente, não prejudica a sua estética e ainda cria um sistema de forças mais definido. Por essas razões e pela utilização clínica dos minimplantes de forma indiscriminada, surgiu o interesse em estudar a perda de ancoragem relacionada aos minimplantes. O objetivo deste trabalho foi comparar, por meio de telerradiografias, panorâmicas e modelos, a perda de ancoragem após a retração inicial de caninos superiores entre dois grupos. Foram selecionados 18 pacientes, divididos em dois grupos aleatórios de 9 indivíduos cada um (A e B), triados para tratamento ortodôntico na Faculdade de Odontologia de Araçatuba - UNESP, Disciplina de Ortodontia. O grupo A utilizou o minimplante enquanto o grupo B utilizou botão lingual. Para todos os pacientes foram realizadas duas telerradiografias (T1 e T2), duas panorâmicas (P1 e P2) e dois modelos (M1 e M2). Os primeiros exames complementares foram realizados ao início (T1, P1 e M1), e o outro, ao final da retração inicial de canino (T2, P2 e M2). Foi eleita a segunda fase (retração inicial de canino), devido à grande perda de ancoragem que se tem neste estágio do tratamento. Todas as medidas foram tabuladas e submetidas a análise estatística. Para comparação entre as fases Início e Após foi utilizado o teste "t" pareado. Para a comparação entre os grupos de minimplante e botão lingual foi utilizado o teste "t" de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Todos os cálculos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The concern with the anchorage is one of the main factors to be considered when planning an orthodontic treatment. Anchorage comprehends intra and extraoral procedures in which one or more teeth or orthodontic devices are used as a support for moving other teeth. The use more constant of implants is derived from a poor patient collaboration, does not impair the esthetics and still creates more defined forces system. For these reasons and because of the mini-implants clinical utilization in an indiscriminate way, there was an increased interest in studying anchorage loss related to mini-implants. The purpose of this study was to compare, by means of teleradiographies, panoramic radiographs and models, the anchorage loss after initial maxillary canine retraction between two groups. Eighteen patients were selected, then randomly divided into two groups of 9 individuals each (A and B), and elected for orthodontic treatment in the Faculty of Dentistry of Araçatuba - UNESP, Orthodontics Department. Group A utilized mini-implant while group B utilized lingual button. For all patients, two teleradiographies (T1 and T2), two panoramic radiographs (P1 and P2) and two models (M1 and M2) were done. The first complementary exams were accomplished in the beginning (T1, P1 and M1) and the other in the end of the initial canine retraction (T2, P2, and M2). The second phase was elected (initial canine retraction) due to the great anchorage loss that exists in this treatment stage. All measurements were tabulated and submitted to statistical analysis. For the comparison between the stages "Beginning" and "After", a paired t test was used. For the comparison between the mini-implant and lingual button groups, a Student's t test for independent measurements was used. In all tests, a significance level of 5% (p<0,05) was adopted. All statistical calculations... (Complete abstract click electronic access below) / Doutor
|
3 |
Comparação quantitativa da retração de caninos superiores utilizando dois sistemas de ancoragem /Kina, Juliana. January 2009 (has links)
Orientador: Eduardo César Almada Santos / Banca: Marcos Rogério de Mendonça / Banca: João Batista de Paiva / Resumo: Introdução: Para a eficiência da ancoragem, diferentes protocolos são preconizados durante a mecânica ortodôntica, principalmente quando se deseja a retração inicial do canino para o alinhamento e nivelamento anterior sem a mesialização do segmento posterior. Nesse contexto, a utilização dos minimplantes tem sido cada vez mais frequente, pois possuem características desejáveis para essa finalidade como a facilidade operacional de sua instalação, dispensa a colaboração do paciente para o desenvolvimento da mecânica ortodôntica,é favorável na estética e permite um sistema de forças mais previsível. O objetivo deste trabalho foi comparar quantitativamente por meio de telerradiografias em norma lateral e radiografias panorâmicas, a taxa de retração inicial de caninos (RIC) superiores, utilizando-se dois sistemas distintos de ancoragem. Métodos: Foram selecionados 18 pacientes, formando dois grupos aleatórios de 9 indivíduos (G1 e G2), triados para tratamento ortodôntico na UNESP - Araçatuba. Como ancoragem foi utilizado minimplantes no grupo G1 e botão de Nance no grupo G2. Para todos os pacientes foram realizadas duas telerradiografias em norma lateral (T1 e T2) e duas panorâmicas (P1 e P2). Para comparação entre as fases Início (antes do tratamento) e Após (após a retração inicial de caninos) foi utilizado o teste t pareado. Para a comparação entre os grupos de minimplante e botão de Nance foi utilizado o teste t de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Resultados: Para a RIC no Grupo G1, obteve-se uma média de 0,63 mm/mês, enquanto para o grupo G2 a média foi de 0,56 mm/mês. Conclusões: A análise das telerradiografias em norma lateral e das radiografias panorâmicas revelou a inexistência de diferença estatisticamente significante entre os dois grupos. / Abstract: Introduction: For efficiency of the anchorage, different protocols are recommended during orthodontic mechanics, especially when clinicians want to retract the initial alignment and leveling without the inclination of the posterior segment. In this context, the use of mini-implants has been frequent. For this purpose it has desirable characteristics, such as the operational facility of installation, the collaboration of the patient, exemption for the development of orthodontic mechanics, it is favorable in appearance and allows more predictable system forces. This study compared, by teleradiographs and panoramic radiographs, the initial rate of retraction of canines (ICR), using two different systems of anchoring. Methods: 18 patients were selected and divided in two random groups of 9 subjects (G1 and G2). They needed and were refered to orthodontic treatment at UNESP - Araçatuba. In G1, mini-implants were used as anchor and G2 used the Nance button appliance. Two teleradiographs (T1 and T2) and two panoramic (P1 and P2) were made for all patients. The paired T test was used for comparison between Initial (before treatment) and After (after the initial retraction of canines) phases. Student's t test for independent measures was used for comparison between groups of mini-implants and the Nance button appliance. A significance level of 5% (p <0.05) was adopted in all tests. Results: For G1, an average of 0.63 mm / month was obtained, while for G2, the average was 0.56 mm / month. Conclusions: The analysis of teleradiographs and panoramic radiographs showed the absence of statistically significant difference between the two groups. / Mestre
|
Page generated in 0.1034 seconds