• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 4
  • 2
  • Tagged with
  • 15
  • 15
  • 11
  • 11
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Órteses em PVC para membro superior: utilização por terapeutas ocupacionais brasileiros, propriedades físicomecânicas e de toxicidade e desempenhos funcional e mioelétrico

Silva, Larissa Galvão da 13 December 2013 (has links)
Made available in DSpace on 2016-06-02T20:44:13Z (GMT). No. of bitstreams: 1 5737.pdf: 4169263 bytes, checksum: 1d29d7112d3353be7cf96c4b7043ae44 (MD5) Previous issue date: 2013-12-13 / Financiadora de Estudos e Projetos / Splints are devices whose function to stabilize, immobilize, prevent and correct deformities and maximizing the function and are currently manufactured in thermoplastic , especially low temperature. Was created a technique for making splints from thermoplastic PVC and high temperature due to the lack of scientific studies of the applicability of PVC for orthosis for the upper limb, proposed a study aiming to meet , compare and analyze aspects concerning the applicability of the materials and wrist splints made of two types of thermoplastics , the high temperature PVC and a low temperature Ezeform ®, commonly used for orthosis . The research involved the analysis of the factors for the use of materials, the analysis of the mechanical properties, thermal and toxicity of both materials and analysis of myoelectric and functional performances of subjects with and without orthoses on functional tests of manual dexterity . It was found that occupational therapists using PVC do this by being accessible in terms of cost of material and using Ezeform, the ease in modeling, PVC has high recyclability, and Ezeform, is more susceptible to deformation; functional performance volunteers with orthotics PVC and Ezeform is hindered significantly; especially with the PVC; the myoelectric activity of the upper fibers of the trapezius increases with both orthoses; especially with Ezeform of the biceps muscle did not change significantly and muscles radial extensor and flexor digitorum superficialis had the myoelectric amplitude decreased when the orthoses used and so that the orthosis with PVC myoelectric activity was lower. / As órteses são dispositivos que tem como função, estabilizar, imobilizar, prevenir e corrigir deformidades e maximizar a função e atualmente são confeccionadas em termoplásticos, especialmente os de baixa temperatura, moldados diretamente sobre o membro. Foi criada uma técnica de confecção em órteses a partir do termoplástico de alta temperatura PVC e devido à falta de estudos científicos da aplicabilidade do PVC para confecção de órteses de membro superior, propôs-se um estudo com o objetivo de conhecer, comparar e analisar os aspectos que envolvem a aplicabilidade e os materiais de órteses de punho confeccionadas em dois tipos de termoplástico, o de alta temperatura, PVC e um de baixa temperatura, Ezeform®, comumente usado para confecção de órteses. A investigação envolveu a análise dos fatores de utilização dos materiais, a análise das propriedades mecânicas, térmicas e toxicidade de ambos os materiais e a análise dos desempenhos funcional e mioelétrico dos sujeitos sem e com as órteses em testes funcionais de destreza manual. Foi verificado que os terapeutas ocupacionais que utilizam PVC o fazem por este ser acessível em termo de custo do material e os que utilizam Ezeform, pela facilidade na modelagem; o PVC possui alta reciclabilidade, e o Ezeform, é mais susceptível à deformações; o desempenho funcional dos voluntários com as órteses de PVC e de Ezeform é dificultado significativamente, especialmente com a de PVC; a atividade mioelétrica das fibras superiores do trapézio aumenta com ambas as órteses, especialmente com a de Ezeform, o músculo bíceps não sofreu alterações significativas e os músculos extensor radial e flexor superficial dos dedos tiveram a amplitude mioelétrica diminuída quando utilizadas as órteses, de modo que com a órtese de PVC a atividade mioelétrica foi menor.
12

Avaliação tridimensional do côndilo mandibular em indivíduos pós-surto de crescimento pubertário após uso de Herbst bandado. / Three-dimensional evaluation of the mandibular condyle in individual post-pubertal growth outbreak after banded herbst use.

Almeida, Kélei Cristina de Mathias 17 March 2017 (has links)
Submitted by Kelei Cristina De Mathias Almeida (keleimathias.almeida@gmail.com) on 2018-09-05T16:47:11Z No. of bitstreams: 1 TESE Doutorado Kélei.pdf: 2128690 bytes, checksum: 6d32a1eacad944a350a690a474e3afa7 (MD5) / Rejected by Ana Cristina Jorge null (anacris@fclar.unesp.br), reason: Solicitamos que faça as seguintes correções: 1) O sumário deve conter todas as seções e subseções da sua tese (Ex. 2.1 Articulação temporomandibular (ATM) , 2.2.......e demais subseções); 2) As keywords devem ser as apresentadas no DECS. As suas palavras chaves em inglês no DECs são : Malocclusion, Angle class II Orthotic devices Cone-beam computed tomography Imaging, three-dimensional 3) Na ficha catalográfica o número correto de páginas é 108 f ; 4) Nos metadados você assinalou que não recebeu financiamento. Porém, na sua tese você agradece ao apoio financeiro da Capes e da Fapesp. Lembre-se que no caso da Fapesp é obrigatório informar também o número do processo; 5) Você não preencheu o nome do seu Programa de pós graduação no metadados; 6) Também não preencheu no metadados a área de concentração. Atenciosamente on 2018-09-05T18:58:25Z (GMT) / Submitted by Kelei Cristina De Mathias Almeida (keleimathias.almeida@gmail.com) on 2018-09-12T02:42:13Z No. of bitstreams: 1 TESE Doutorado Kélei Almeida.pdf: 2132229 bytes, checksum: f4f99b7fff170f591582b5ec78cec062 (MD5) / Approved for entry into archive by Ana Cristina Jorge null (anacris@fclar.unesp.br) on 2018-09-12T13:08:39Z (GMT) No. of bitstreams: 1 almeida_kcm_dr_arafo_int.pdf: 2132229 bytes, checksum: f4f99b7fff170f591582b5ec78cec062 (MD5) / Made available in DSpace on 2018-09-12T13:08:39Z (GMT). No. of bitstreams: 1 almeida_kcm_dr_arafo_int.pdf: 2132229 bytes, checksum: f4f99b7fff170f591582b5ec78cec062 (MD5) Previous issue date: 2017-03-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo prospectivo foi avaliar tridimensionalmente a remodelação e o deslocamento do côndilo mandibular na fossa articular nos indivíduos, pós-surto de crescimento pubertário, tratados com aparelho Herbst bandado. A amostra foi constituída por 24 indivíduos, de ambos os gêneros, leucodermas, com idade cronológica média de 16 anos e 1 mês. Os indivíduos foram tratados com aparelho Herbst bandado por um período de 8 meses (média da amostra: 9,8 meses). Para a avaliação da remodelação do côndilo mandibular foram utilizadas tomografias computadorizadas de feixe cônico (TCFC) em dois tempos, denominados de T1 (antes da colocação do aparelho e T2 (após a remoção do mesmo). As tomografias foram obtidas pelo tomógrafo i-CAT Classic e os dados foram exportados no formato DICOM (Digital Image and Comunication in Medicine) e avaliados no programa Dolphin® Imaging 11.5 Premium. As medidas foram analisadas nas imagens dos cortes multiplanares (planos coronal, sagital e axial) por um observador, previamente calibrado. Os dados obtidos foram calculados pelo sistema de coordenadas cartesianas tridimensionais em um programa de software Matlab desenvolvido pelo Departamento de Física e Biofísica, da Faculdade Estadual Paulista – UNESP de Botucatu. Para avaliar o grau de concordância entre as mensurações empregouse o coeficiente de correlação intraclasse (ICC). À exceção das medidas FOE (eixo Z), C1E (no eixo X) e C2-T2 em ambos os lados, todas as demais medidas apresentaram alto grau de reprodutibilidade, denotando que o erro do método pode ser desprezado. O deslocamento dos côndilos, no sistema de coordenadas cartesianas, foi calculado com o Ponto Zero na Base do crânio; a remodelação foi calculada com o Ponto Zero na média da distância dos forames mentuais direito e esquerdo, forneceu uma análise quantitativa e qualitativa e distâncias euclidianas. Com relação a base do crânio, o côndilo direito se deslocou de forma moderada (0,71mm) para baixo e de forma relevante (0,91mm) para frente; o côndilo esquerdo se deslocou de forma relevante (0,93mm) para baixo e de forma moderada (0,73mm) para frente. O côndilo direito remodelou de forma relevante 1,08mm para trás e se distanciou da média da distância dos forames mentuais de forma relevante (1,19mm); o côndilo esquerdo remodelou de forma relevante 0,98mm para cima e se distanciou da média da distância dos forames mentuais de forma relevante (0,93mm). Foram mensurados os espaçamentos entre os pontos nos côndilos direito e esquerdo, em relação a fossa articular, sendo observado aumento de forma média, do espaçamento superior do côndilo esquerdo (0,34mm). O tratamento não promoveu alterações significantes nas medidas no eixo X, constatando que não houve movimento de lateralidade. Conclui-se que, com relação a base do crânio, os côndilos direito e esquerdo se deslocaram para baixo e para frente. O côndilo direito remodelou para trás enquanto que o côndilo esquerdo remodelou para cima. / The aim of this prospective study was to evaluate in 3-D the remodeling and displacement of the mandibular condyle in the glenoid fossa in the individuals, post-pubertal growth outbreak, treated with the banded Herbst appliance. The sample consisted of 24 individuals of both genders, leucoderma, with a mean chronological age of 16 years and 1 month. Subjects were treated with banded Herbst appliance during 8 months. Cone beam computed tomography (CBCT) was performed in two times to evaluate the condylar remodeling: T1 (prior to placement of the device) and T2 (after removal).) CT scans were obtained by i-CAT tomography Classic and the data were exported in DICOM (Digital Image and Communication in Medicine) format and evaluated in the Dolphin® Imaging 11.5 Premium program. The measurements were analyzed in multiplanar sections images (coronal, sagittal and axial planes) by an observer, previously calibrated. The data obtained were calculated by 3-D Cartesian coordinate system in a Matlab software, developed by the Department of Physics and Biophysics, UNESP Botucatu. To evaluate the agreement degree between the measurements, the intraclass correlation coefficient (ICC) was used. With the exception of the measurements FOE (Z axis), C1E (X axis) and C2-T2 on both sides, all other measurements showed a high degree of reproducibility, denoting that the error of the method can be neglected. The displacement of the condyles in the Cartesian coordinate system was calculated with the Zero Point in the skull base; the remodeling was calculated with the Point Zero in the mean distance of the right and left mental foramina, provided a quantitative and qualitative analysis and Euclidean distances. In relation to skull base, the right condyle moved moderately (0.71 mm) downwards and significantly (0.91 mm) forward; the left condyle shifted significantly (0.93mm) downwards and moderately (0.73mm) forward. The right condyle significantly remodeled 1.08mm behind and distanced itself from the mean distance of the mental foramina significantly (1.19mm); the left condyle significantly reshaped 0.98mm upward and distanced itself from the mean distance of the mental foramina significantly (0.93mm). The spacing between the points on the right and left condyles were measured, in relation to the glenoid fossa; there was a mean increase in the superior space of the left condyle (0.34 mm). The treatment did not promote significant changes in the measurements on the X axis, noting that there was no laterality movement. It was concluded that, with respect to the skull base, the right and left condyles moved downwards and forward. The right condyle remodeled backwards while the left condyle remodeled upward. / 2010/17934-8
13

Avaliação de endoprótese nacional em traquéia de coelhos. / Auto-expansible endoprosthesis. Biocompatibility in rabbits trachea.

Faria, Celso Murilo Nálio Matias de 22 November 2011 (has links)
Made available in DSpace on 2016-01-26T12:51:38Z (GMT). No. of bitstreams: 1 celsomurilonmdefaria_dissert.pdf: 1426679 bytes, checksum: 62fc4b90d691c716aef67c9e6590368e (MD5) Previous issue date: 2011-11-22 / Introduction: the utilization of endoprosthesis has its main indication in the neoplasic obstructions do not surgically treatable. The foreign industry dependence is one of the barriers we found for the broad utilization of such devices. The relevance of this research is the development of a national prosthesis from easy access and low cost. Objective: to assess the biocompatibility of nitinol endoprosthesis with polyurethane in the rabbits trachea. Material and Method: Seventeen rabbits were studied from the New Zealand breed (Oryctolagus Sylvilagus), eight male and five female, with an average weight of 3255g (from 2570 to 4270g). The endoprosthesis were applied orally through laringoscopy, under general anesthesia and released in the middle third of the trachea. Radiological study was made to assure the placement of the endoprosthesis that allowed to compare the index of migration of the endoprosthesis in millimeters. The proposed time segment was 30 days. The microscopic variables study was proceeded: dilatation, incorporation and granolomatous tissue and histological cuts from the tracheal and lungs segments for microscopic study. The histological study measured the inflammatory process, the parietal alterations and the kind of epithelium observed in the tracheal bed. Results: Thirteen animals were included in the final study. The average segment time was 26 days (15 to 35 days in observation). Six animals underwent a radiological study during euthanasia and it was demonstrated displacement with migration of the prosthesis for the distal trachea in five animals. There was absence in one. It was shown the prosthesis had a complete expansion in seven animals and partial expansion in six. The incorporation of prosthesis in the tracheal lumen was observed in two animals and adhered in eleven. Granulomatous tissue was present in ten animals and absent in three. The histological study of the mucosa and submucosa showed inflammatory process predominantly of Polymorphonuclear cells as in the contact region with the prosthesis as in the proximal. The depth of the inflammatory process in the tracheal wall was larger in the tracheal area in contact with the prosthesis. The alterations of the respiratory epithelium: the metaplasia parameter was the most frequent in the area without contact with the prosthesis. Corrosion and ulceration were predominant in the area in contact with the prosthesis. The metaplasia parameter was the most frequent in the area in contact with the prosthesis. Conclusion: the nitinol endoprosthesis auto-expandable covered with polyurethane, produced by Braile Biomédica and implanted in the trachea of rabbits was easy to apply and liberation in the tracheal lumen. The endoprosthesis recovered with polyurethane showed in radiographic assessment distal migration, good radial expandability and formation of granuloma tissue. It was also observed an inflammatory process predominantly acute and restricted to the superficial portions of the trachea. The most frequent epithelium alterations in contact with the prosthesis were ulceration and regenerative hyperplasia. / Introdução: a utilização de endoprótese tem a principal indicação nas obstruções neoplásicas e nas obstruções não tratáveis cirurgicamente. A dependência da indústria estrangeira é uma das barreiras para utilização ampla destes dispositivos. A relevância deste trabalho é o desenvolvimento de uma prótese nacional de fácil acesso e baixo custo. Objetivo: avaliar endoprótese de nitinol revestida com poliuretano, na traqueia de coelhos. Material e Método: foram estudados 17 coelhos, da raça Nova Zelândia (Oryctolagus Cuniculus). Oito machos e nove fêmeas, com peso médio de 3522g (de 2570 a 4270g). As endopróteses foram aplicadas via oral, por meio de laringoscopia, sob anestesia geral, e liberadas no terço médio das traqueias. Realizou-se estudo radiológico para assegurar a posição da endoprótese que permitiu comparar o índice de migração da endoprótese em milímetros. O tempo proposto de seguimento foi de 30 dias. Procedeu-se ao estudo das variáveis macroscópicas: dilatação, incorporação e tecido de granulação e cortes histológicos dos segmentos traqueais e pulmonares para estudo microscópico. O estudo histológico mensurou o processo inflamatório, as alterações parietais e o tipo de epitélio observado no leito traqueal. Resultados: 13 animais foram incluídos no estudo definitivo. O tempo médio de seguimento foi 26 (15 a 35) dias em observação. Em seis animais submetidos a estudo radiológico por ocasião da eutanásia, demonstrou-se deslocamento com migração da prótese para traqueia distal, em cinco; ausência de migração em um. Demonstrou-se que a prótese tinha expansão completa em sete animais e parcial em seis. A incorporação da prótese na luz traqueal foi observada em dois animais, e aderido em 11. Tecido de granulação esteve presente em dez animais e ausente em três. O estudo histológico da mucosa e submucosa demonstrou processo inflamatório com predomínio de polimorfonucleares tanto na região em contato com a prótese quanto na proximal. A profundidade do processo inflamatório na parede traqueal foi maior na área traqueal em contato com a prótese. Das alterações do eptélio respiratório, o parâmetro metaplasia foi o mais frequente na área sem contato com a prótese. Corrosão e ulceração predominaram na área em contato com a prótese. Conclusões: A escolha do coelho no desenho do presente estudo prejudicou o resultado. Trata-se de estudo pioneiro tanto na utilização de coelho para estudo de endoprótese, quanto no desenvolvimento de endoprótese metálica autoexpansível nacional. As dificuldades foram naturais deste pioneirismo, mas prejudicaram o resultado final. A endoprótese autoexpansível de nitinol recoberta de poliuretano, produzida pela Braile Biomédica Ltda, (Brasil) e implantada na traqueia de coelhos, demonstrou-se de fácil aplicação e liberação na luz traqueal. Apresentou elevada taxa de migração, boa expansibilidade radial. Verificou-se alta frequência na formação de tecido de granulação e baixa permeabilidade. Observou-se ainda processo inflamatório predominantemente agudo e restrito ás porções superficiais da traquéia. As alterações epiteliais mais freqüentes em contato com a prótese foram ulceração e hiperplasia regenerativa.
14

Importância da podobarometria computadorizada na prescrição de órteses para redução das hemartroses de repetição dos tornozelos, em pacientes hemofílicos / Significance of the computerised pedobarography to prescription of orthosis for repetitive ankle haemarthrosis reduction, on hemophilic patients.

Jorge Filho, Donaldo 02 March 2005 (has links)
As hemartroses, a despeito dos avanços terapêuticos ocorridos na hemofilia, continuam sendo os eventos clínicos mais freqüentes. As hemartroses de repetição, sobretudo nos tornozelos, podem estar associadas à instabilidade articular. Sabe-se que a instabilidade articular pode contribuir para aumentar a frequência dessas complicações e prescrevem-se órteses que limitam muito os pacientes. Diante desse quadro buscamos um instrumento para qualificar os desvios nos tornozelos instáveis durante a marcha, dinamicamente e em tempo real. Essa avaliação permitiu a prescrição de palmilhas de fácil confecção, de calçados com contrafortes posteriores e, nos casos muito instáveis, a associação de órteses funcionais, dinâmicas, para tornozelos. A intervenção realizada nos pacientes constou do exame pela podobarometria dinâmica computadorizada, antes e depois da prescrição das órteses. O uso das órteses prescritas conforme as observações podobarométricas permitiu liberdade na marcha, assegurando estabilidade articular. O número de hemartroses nos tornozelos e o consumo de fatores da coagulação em cada hemorragia, nos 43 hemofílicos avaliados, foi verificado nos prontuários médicos dos pacientes, em suas instituições de origem, nos seis meses pré-intervenção e nos seis meses pós-intervenção. Nos 43 hemofílicos avaliados, a média de ocorrência de hemartroses, que era de 4,81, foi reduzida para 2,53 hemartroses por paciente, após a intervenção. A média do consumo de fatores da coagulação reduziu de 9647,7 IU para 4407,0 IU, com p<0,001 . Com base na análise dos resultados concluímos que a podobarometria dinâmica computadorizada é um meio diagnóstico útil na prescrição de estabilizadores para os tornozelos dos hemofílicos, contribuindo significantemente para a redução da incidência de hemartroses. / The haemarthrosis, despite the improvement of therapeutic resources occurred in haemophilia, have been the most frequent haemophiliac\'s clinical event. The repetitive haemarthrosis, speccialy those occurred in ankle joints, could be associated to ankle instabilities. It is known that the joint instability can contribute to increase the frequency of those complications and are prescribed orthosis which severely limit the patients. Face to these facts, we have searched for an instrument able to qualify the deviations in the unstable ankles during the gait, dynamically and in real time. Such evaluation would allow the prescription of insoles, of shoes with posterior counters and, in very unstable cases, the association of dynamic supports. The intervention performed in the patients was constituted of the computerised dynamic pedobarography examination, before and after the prescription of the orthosis. The use of the prescribed orthosis according to the pedobarographic observations allowed joint stability with gait liberty. The number of haemarthrosis in the ankles and the consumption of coagulation factors in each bleeding of the 43 haemophilic evaluated was verified in the patients\' medical records, in their original institutions, in the six months that preceded evaluation and therapeutic intervention in haemophilic patients and during the six months after it. In the 43 evaluated haemophilic patients, the average occurrence of haemarthrosis went from 4,81 episodes before intervention to 2,53 episodes after the intervention. The average coagulation factors consumption went from 9.647,7 IU to 4.407,0 IU. The p value is smaller than 0,001. Based on the analysis of the results, we are able to conclude that the computerised dynamic pedobarography is a useful diagnosis method with a significant contribution to the reduction of incidence of ankle haemarthrosis.
15

Importância da podobarometria computadorizada na prescrição de órteses para redução das hemartroses de repetição dos tornozelos, em pacientes hemofílicos / Significance of the computerised pedobarography to prescription of orthosis for repetitive ankle haemarthrosis reduction, on hemophilic patients.

Donaldo Jorge Filho 02 March 2005 (has links)
As hemartroses, a despeito dos avanços terapêuticos ocorridos na hemofilia, continuam sendo os eventos clínicos mais freqüentes. As hemartroses de repetição, sobretudo nos tornozelos, podem estar associadas à instabilidade articular. Sabe-se que a instabilidade articular pode contribuir para aumentar a frequência dessas complicações e prescrevem-se órteses que limitam muito os pacientes. Diante desse quadro buscamos um instrumento para qualificar os desvios nos tornozelos instáveis durante a marcha, dinamicamente e em tempo real. Essa avaliação permitiu a prescrição de palmilhas de fácil confecção, de calçados com contrafortes posteriores e, nos casos muito instáveis, a associação de órteses funcionais, dinâmicas, para tornozelos. A intervenção realizada nos pacientes constou do exame pela podobarometria dinâmica computadorizada, antes e depois da prescrição das órteses. O uso das órteses prescritas conforme as observações podobarométricas permitiu liberdade na marcha, assegurando estabilidade articular. O número de hemartroses nos tornozelos e o consumo de fatores da coagulação em cada hemorragia, nos 43 hemofílicos avaliados, foi verificado nos prontuários médicos dos pacientes, em suas instituições de origem, nos seis meses pré-intervenção e nos seis meses pós-intervenção. Nos 43 hemofílicos avaliados, a média de ocorrência de hemartroses, que era de 4,81, foi reduzida para 2,53 hemartroses por paciente, após a intervenção. A média do consumo de fatores da coagulação reduziu de 9647,7 IU para 4407,0 IU, com p<0,001 . Com base na análise dos resultados concluímos que a podobarometria dinâmica computadorizada é um meio diagnóstico útil na prescrição de estabilizadores para os tornozelos dos hemofílicos, contribuindo significantemente para a redução da incidência de hemartroses. / The haemarthrosis, despite the improvement of therapeutic resources occurred in haemophilia, have been the most frequent haemophiliac\'s clinical event. The repetitive haemarthrosis, speccialy those occurred in ankle joints, could be associated to ankle instabilities. It is known that the joint instability can contribute to increase the frequency of those complications and are prescribed orthosis which severely limit the patients. Face to these facts, we have searched for an instrument able to qualify the deviations in the unstable ankles during the gait, dynamically and in real time. Such evaluation would allow the prescription of insoles, of shoes with posterior counters and, in very unstable cases, the association of dynamic supports. The intervention performed in the patients was constituted of the computerised dynamic pedobarography examination, before and after the prescription of the orthosis. The use of the prescribed orthosis according to the pedobarographic observations allowed joint stability with gait liberty. The number of haemarthrosis in the ankles and the consumption of coagulation factors in each bleeding of the 43 haemophilic evaluated was verified in the patients\' medical records, in their original institutions, in the six months that preceded evaluation and therapeutic intervention in haemophilic patients and during the six months after it. In the 43 evaluated haemophilic patients, the average occurrence of haemarthrosis went from 4,81 episodes before intervention to 2,53 episodes after the intervention. The average coagulation factors consumption went from 9.647,7 IU to 4.407,0 IU. The p value is smaller than 0,001. Based on the analysis of the results, we are able to conclude that the computerised dynamic pedobarography is a useful diagnosis method with a significant contribution to the reduction of incidence of ankle haemarthrosis.

Page generated in 0.1034 seconds