• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 224
  • 12
  • 12
  • 12
  • 12
  • 9
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 234
  • 140
  • 139
  • 122
  • 100
  • 97
  • 52
  • 48
  • 36
  • 34
  • 28
  • 28
  • 27
  • 27
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo comparativo in vivo de implantes Ti-cp com superfícies comerciais e modificadas por laser sem e com depósito de sílica: análises biomecânica, topográfica e histomorfométrica

Souza, Francisley Ávila [UNESP] 30 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-30Bitstream added on 2014-06-13T18:41:42Z : No. of bitstreams: 1 souza_fa_dr_araca.pdf: 2491659 bytes, checksum: 017388e8b7b826e5dad08553556571ca (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição: O objetivo deste estudo foi comparar o comportamento biológico e mecânico do tecido ósseo ao redor de implantes de superfícies comerciais modificada por condicionamento ácido (SA), e usinada (SU), com implantes de superfícies experimentais modificada por laser (SL), e modificada por laser com depósito de sílica (SS), empregando-se as análises biomecânica, topográfica e histométrica. Material e Métodos: Trinta coelhos receberam 120 implantes de 3,75x10mm em suas tíbias direita e esquerda, sendo dois implantes de cada superfície por tíbia. O implante localizado mais superior, instalado na metáfise tibial foi utilizado para o ensaio biomecânico, descrito no capítulo I; e o implante localizado abaixo deste, instalado na epífise tibial foi utilizado para o estudo histométrico, descrito no capítulo II. A morfologia das superfícies dos implantes foi analisada por microscopia eletrônica de varredura (MEV), e por espectroscopia de energia dispersiva de raios X (EDS) antes, e após 4 semanas de implantação e remoção por torque reverso. Medidas de rugosidade e secção transversal foram obtidas. Após períodos de 4, 8, e 12 semanas realizou-se o ensaio biomecânico, e após os animais sofreram eutanásia. As peças do implante localizado na epífise tibial foram levadas ao micrótomo para corte sem descalcificação. A análise histométrica foi realizada empregando-se microscopia óptica. Foi mensurada a extensão linear de contato entre osso e implante (ELCOI), e a área óssea (AO). Uma lâmina de cada superfície do período de 4 semanas foi metalizada para realização da análise do mapeamento elementar por MEV-EDS. Resultados: A caracterização topográfica mostrou diferenças entre as superfícies analisadas, e os valores de rugosidade média das SL e SS foram estatisticamente superiores (p<0,05) a SA. Na comparação estatística dos valores obtidos... / Purpose: The aim of this study was to compare the biologic and mechanical behavior of bone tissue around implants with commercially available surfaces, modified by acid etching (SA), and machined surfaces (SU), with the experimental surfaces modified by laser (SL), and modified by laser with silica deposition (SS), using biomechanical, topographic and histometric analyses. Materials and Methods: Thirty rabbits received 120 implants measuring 3,75x10mm in their right and left tibias, being two implants of each type of surface per tibia. The implant located in the uppermost position, inserted in the tibial metaphysis, was used for the biomechanical test, described in Chapter I; and the implant located below this, inserted in the tibial epiphysis, was used for the histometric study, described in Chapter II. The morphology of the implant surfaces was analyzed by scanning electron microscopy (SEM) and by energy dispersive X-ray spectrometry (EDS) before and after 4 weeks of implantation and removal by reverse torque. Mean roughness and cross-sectional measurements were obtained. After periods of 4, 8, and 12 weeks the biomechanical test was performed, and after this the animals were euthanized. The parts of the implant located in the tibial epiphysis were taken for cutting nondecalcified on a microtome. Histometric analysis was performed using an optical microscope. The bone interface contact (BIC), and the bone area (AO) were measured in percentages. A slide of each surface in the period of 4 weeks was metalized in order to analyze the element mapping by means of SEM-EDS. Results: The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of SL and SS were statistically higher (p<0,05) than those of SA. In the statistical comparison of the values obtained by the biomechanical test, it was... (Complete abstract click electronic access below)
32

Reparação do tecido ósseo peri-implantar após enxerto ósseo autógeno e heterógeno: estudo experimental histológico em cães

De Santis, Enzo [UNESP] 05 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-05Bitstream added on 2014-06-13T21:04:26Z : No. of bitstreams: 1 desantis_e_dr_araca.pdf: 2787266 bytes, checksum: b11c83dbba262a0641d23d2d0ceb74da (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: avaliar a regeneração da crista óssea alveolar e o processo de osseointegração de implantes instalados em sítios enxertados com blocos de osso autógeno e osso bovino mineral (DBBM),associado a membrana de colágeno. Material e método: em 6 cães labradores foram extraidos os molares inferiores bilateralmente, nos quais foi removida a tábua óssea vestibular, criando-se um defeito em formato de caixa. Após 3 meses de regeneração, os retalhos foram elevados e posicionado um guia com uma lima endodôntica, com a finalidade de alinhar paralelamente à parede vestibular do defeito. O guia foi removido e, no lado direito inferior (grupo controle), foi obtido um enxerto ósseo do ramo ascendente da mandibula, que foi fixado a parede lateral do defeito por meio de parafusos. No lado esquerdo inferior (grupo teste), foi fixado um bloco de DBBM no defeito mandibular. Em ambos os lados, os blocos enxertados foram protegidos por uma membrana de colágeno reabsorvível. Em seguida os retalhos foram suturados. Após elevação do retalho, utilizou-se o guia para instalação de um implante de cada lado da mandíbula, entre o enxerto e o osso remanescente. Após 3 meses, os animais foram eutanasiados para obtenção das peças a serem processadas laboratorialmente para análise histológica. Resultados: Todos os implantes apresentaram-se clinicamente estáveis. A espessura da crista alveolar no grupo teste foi de 5.4, 9.4 e 9.3 mm, antes, imediatamente após a enxertia, e no momento da instalação dos implantes respectivamente. No grupo controle (enxerto ósseo autógeno), a espessura da crista alveolar foi de 5.2, 9.0 mm antes e imediatamente após o procedimento de enxertia (reconstrução). Após 3 meses... / Aim: - to evaluate the healing of the alveolar bony crest and the integration of implants installed in augmented sites with autologous bone or DBBM blocks, concomitantly with a collagen membrane. Material & methods: Mandibular molars were extracted bilaterally in 6 Labrador dogs, the buccal bony wall was removed and a box-shaped defect was created. After 3 months, flaps were elevated and a device was applied to a stent and used for the placement of an endodontic file that was lined up parallel to the buccal wall of the defect. The stent was removed and, in the right mandibular side, a bony graft was harvested from the ascending ramus and secured to the lateral wall of the defect by means of screws. In the left mandibular side, a DBBM block was fixed to the defect. A resorbable membrane was applied both sides. The flaps were sutured. After three months, one bone graft was exposed, and the dog was excluded from further analysis. After flap elevation, the stent and the device were used as guide to install one implant in each mandibular side, between the graft and the parent bone. After 3 months, biopsies were harvested and ground sections prepared for histological evaluation. Results: All implants were clinically stable. The width of the alveolar crest at the test sites was 5.4mm before, 9.4mm immediately after grafting, and 9.3mm at implant installation. At the control sites (autologous bone graft), the width of the alveolar crest was 5.2mm before and 9.0mm immediately after the grafting procedure. After 3 months of healing, the width was 8.7mm. One autologous bone block graft was lost before implant installation. All implants installed were available for histological evaluation (n=5). The autologous bone... (Complete abstract click electronic access below)
33

Efeito da deficiência de magnésio sobre o metabolismo do tecido ósseo

Belluci, Marina Montosa [UNESP] 23 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-23Bitstream added on 2014-06-13T21:06:13Z : No. of bitstreams: 1 belucci_mm_dr_arafo.pdf: 1097324 bytes, checksum: 8187e99752ed7ef6feeaf20d01248e04 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O magnésio (Mg+2) é um mineral que possui um importante papel na homeostase mineral, podendo afetar diretamente a função das células ósseas e a formação da hidroxiapatita. Entretanto, até o presente momento existem poucos estudos avaliando os mecanismos relacionados à alteração do metabolismo ósseo frente à deficiência de Mg. O objetivo desse estudo foi avaliar, in vitro, o efeito da deficiência de magnésio sobre a osteoclastogênese e atividade de osteoclastos. Também foi objetivo avaliar, in vivo, o efeito da deficiência de magnésio na dieta sobre o metabolismo ósseo, doença periodontal e tecido ósseo ao redor de implantes com osseointegração estabelecida. Para o estudo in vitro, foram avaliadas células indiferenciadas da medula óssea de ossos longos e mandíbula de camundongos. As células foram cultivadas em plástico e sobre tecido ósseo, em meios de cultura com diferentes concentrações de Mg (0.8 Mm que é considerada a quantidade adequada de Mg; e meios com redução do Mg, 0.4 Mm; 0.08 Mm; e 0 Mm). Após 3 dias de cultura, foram avaliadas a viabilidade celular, a taxa de proliferação celular e a expressão gênica, por PCR, de genes relacionadas à osteoclastogênese (c-fms, RANK, DC STAMP, c-fos, TNF-α e IL-1β) e ao metabolismo do Mg (TRPM-7 e MRS2). Após 6 dias de cultura, foram avaliados os parâmetros: número de células osteoclásticas (coloração de TRACP), atividade (liberação de TRACP) e taxa de proliferação celular. Após 8 dias de cultura a atividade dos osteoclastos foi avaliada por análise de pit de reabsorção. Para o estudo in vivo, foram utilizados 30 ratos, divididos em 2 grupos: grupo controle (CTL), que recebeu dieta com conteúdo adequado de magnésio, e grupo Mg, que recebeu dieta... / Magnesium (Mg) deficiency is very common condition in the world population. This mineral has an important role on bone homeostasis. However, there has been little research regarding the mechanisms in which magnesium deficiency alters bone metabolism. Also, the understanding of the factors associated to bone metabolism is of interesting for the prognosis of oral therapies, such as on periodontal disease and on osseointegrated dental implants. The aim of this study was to evaluate, in vitro, whether Mg deficiency affects the formation and/or activity of osteoclasts. And also to evaluate, in vivo, the effect of Mg intake deficiency on bone metabolism, periodontal disease and the bone tissue around osseointegrated implants. For the in vitro study, bone marrow cells from long bone and jaw of mice were seeded on plastic and on bone in medium containing different concentrations of Mg (0.8 mM which is 100% of the normal value, 0.4, 0.08 and 0 mM). The effect of Mg deficiency was evaluated on cell viability after 3 days and proliferation rate after 3 and 6 days, as was mRNA expression of osteoclastogenesis-related genes (M-CSF, RANK, c-fos, DC STAMP, TNF-α and IL-1β) and Mg-related genes (TRPM7 and MRS2). After 6 days of incubation, the number of tartrate resistant acid phosphatase-positive multinucleated cells (TRACP+-MNCs) was determined, and the TRACP activity of the medium was measured. Osteoclastic activity was assessed at 8 days by resorption pit analysis. For the in vivo studies, 30 rats received an implant in the right tibial metaphysis. After 60 days for healing of the implants, the animals were divided into groups according to the diet received. Control group (CTL) received a standard diet with adequate... (Complete abstract click electronic access below)
34

Processo de reparo ósseo diante de três tipos de superfície de titânio: análise histomorfométrica e por microscopia eletrônica de varredura associada ao EDS: estudo experimental

Francisconi, Giovanna Barbosa [UNESP] 11 August 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-08-11Bitstream added on 2015-05-14T16:59:19Z : No. of bitstreams: 1 000826475.pdf: 1230617 bytes, checksum: 9906192468cedb06e3bcaba8d01384f7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição: Tendo em vista a influência positiva do tratamento de superfície do implante no processo de reparo e/ou regeneração óssea peri-implantar, propusemos neste estudo caracterizar histologicamente o tecido ósseo neoformado em condições diferentes de superfícies de titânio. Material e Método: foram realizados procedimentos cirúrgicos em 75 ratos (Rattus norvegicus albinus,Wistar), divididos em 3 grupos de 25 animais, onde se obteve acesso ao terço superior da tíbia direita de cada rato para a posterior instalação dos implantes. O 1º grupo recebeu o implante de superfície polida (GRUPO POLIDO - GP), o 2° recebeu um implante com superfície usinada (GRUPO USINADO - GU) e o 3º grupo recebeu o implante de superfície tratada com ácido (GRUPO TRATADO - GT). No total foram 3 grupos, 25 implantes por grupo e 1 implante por animal. Nos períodos de 3, 7, 15, 21 e 40 dias pós-operatórios, os animais foram submetidos à eutanásia e com as amostras teciduais obtidas foram realizadas as análises histomorfométricas, por microscopia eletrônica de varredura (MEV) e Espectroscopia de Raios X por Dispersão em Energia (EDS). Resultados: O resultado das análises por MEV das superfícies demonstrou diferenças topográficas entre elas, sendo a superfície mais lisa e regular a do GP, seguida pela superfície do GU e, por fim, a superfície com maior rugosidade, a do GT. Comparando-se os valores de BIC (Bone to Implant Contact) dos três grupos para um mesmo período (medindo tanto osso em contato com a região cortical quanto medular da tíbia), houve diferença estatisticamente significante (p<0,05) somente no período inicial de osseointegração (7 dias) entre os valores de GP e GT, onde p=0,0189 e a porcentagem de BIC foi de 70% e 94%, respectivamente. Conclusão: O processo de osseointegração dos implantes aconteceu com o mesmo padrão qualitativo tanto nas superfícies... / Purpose: Given the positive influence of the surface treatment of implants in the healing and/or peri-implant bone regeneration process, we proposed on this study histologically characterize the newly formed bone tissue under different titanium surfaces. Material and Methods: Surgical procedures were performed on 75 rats (Rattus norvegicus Albinus, Wistar) were divided into 3 groups of 25 animals, where we had access to the upper third of the right tibia of each rat for the subsequent installation of the implants. The first group received the implant polished surface (POLISHED GROUP - GP), the second received an implant with machined surface (MACHINED GROUP - GU) and the third group received the implant surface treated with acid (TREATED GROUP - GT). In total there were 3 groups, 25 implants per group and 1 implant per animal. In periods of 3, 7, 15, 21 e 40 postoperative day, the animals were euthanized and tissue samples obtained were submitted to the histomorphometric analyses by scanning electron microscopy (SEM) and were performed by Energy Dispersive X Ray Spectroscopy (EDS). Results: The results of SEM analysis of the surfaces showed topographical differences among them being the most smooth and regular surface of the GP, then the surface of the GU and, finally, with greater surface roughness, the GT. Comparing the BIC values of the three groups for the same period (measuring both cortical as trabecular region of the tibia), a statistically significant 17 difference (p <0.05) was found only in the initial period of osseointegration (7 days) between the GP and GT values, where p = 0.0189 and the BIC percentage was 70% and 94%, respectively. Conclusion: The process of osseointegration of implants happened with same quality standard in both polished surfaces (GP), as on machined (GU) and treated with acid subtraction (GT). In contact with the surface...
35

Utilização sistêmica de estrôncio não radioativo como potencializador da osseointegração de implantes: avaliação biomeânica, microtomográfica e histomorfométrica em ratos

Scardueli, Cássio Rocha [UNESP] 25 March 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-25Bitstream added on 2014-12-02T11:21:07Z : No. of bitstreams: 1 000800880.pdf: 720556 bytes, checksum: 98904c318206483604d36216d6313baf (MD5) / Medicamentos a base de bisfosfonatos têm sido amplamente empregados para tratar enfermidades como osteoporose, mieloma múltiplo, doenças reumáticas e neoplasias com metástases ósseas. No entanto, não podem ser usados rotineiramente na clínica odontológica em favor da maior reparação óssea e osseointegração devido a seus mecanismos específicos e por estarem constantemente relacionados a problemas como alta permanência da droga no organismo e risco de necroses ósseas. Medicamentos a base de estrôncio surgem como novas formas de tratamento para pacientes osteoporóticos bem como uma possível indicação para o uso coadjuvante em procedimentos cirúrgicos, favorecendo a nova formação óssea. Diante das vantagens oferecidas pelos medicamentos a base de estrôncio, como ranelato de estrôncio e cloreto de estrôncio/carbonato de estrôncio, este trabalho teve como objetivo avaliar a osseointegração de implantes em tíbias de ratos. Foram utilizados 70 ratos Rattus Norvegicus, machos, divididos aleatoriamente em 5 grupos: S-Controle (soro); RE 50 (Ranelato de Estrôncio 50 mg); RE 625 (Ranelato de Estrôncio 625 mg); ClECaE 30 (Cloreto Estrôncio e Carbonato Estrôncio 30 mg); ClECaE 365 (Cloreto Estrôncio e Carbonato de Estrôncio 365 mg). Os medicamentos foram administrados diariamente, via gavagem, de acordo com cada grupo, iniciando 15 dias antes do procedimento cirúrgico (1 implante em cada tíbia), persistindo até o final do experimento 15 ou 60 dias. Testes biomecânicos foram realizados com os implantes do lado direito através do contra-troque de remoção, e os implantes no lado esquerdo foram realizadas microtomografias e análises histomorfométricas. Os resultados mostraram uma melhora na osseointegração, principalmente nos grupos ranelato estrôncio 62mg e cloreto estrôncio/carbonato estrôncio 365mg nos testes biomecânicos e microtomográficos. O medicamento a base de estrôncio teve uma influência positiva... / Drugs containing bisphosphonates have been widely used to treat diseases such as osteoporosis, multiple myeloma, myeloproliferative disease and cancer with bone metastases. However, can not be used routinely in dental practice in favor of greater bone repair and osseointegration due to its specific mechanisms and are constantly related issues such as high permanence of the drug in the body and risk of bone necrosis. Drugs based on strontium emerge as new forms of treatment for osteoporotic patients as well as a possible indication for adjuvant use in surgical procedures, promoting new bone formation. Given the advantages offered by drugs containing strontium as strontium ranelate and strontium chloride/strontium carbonate , this study aimed to evaluate the osseointegration of implants in rat tibia. Were used 70 rats Rattus Norvegicus, males, randomly divided into 5 groups: S (control-serum physiologic); RE50 (Strontium Ranelate 50 mg); RE 625 (Strontium Ranelate 625 mg); ClE/CaE 30 (Strontium Carbonate and Strontium Chloride 30 mg); ClE/CaE 365 (Strontium Carbonate and Chloride Strontium 365 mg). The drugs were administered daily by gavage according to each group, starting 15 days before surgery (1 implant in each tibia) and persisted until the end of the experiment 15 or 60 days. Biomechanical tests were performed with the right implants through shift against removal, and implants in the left side microtomography and histomorphometric analysis were performed. The results showed an improvement in osseointegration, especially in groups strontium ranelate 625mg and strontium cloride/strontium carbonate 365mg in microtomography and biomechanical testing. The drug strontium base had a positive influence on osseointegration of implants, especially strontium chloride/strontium carbonate, can be incorporated into prevention, treatments of pathologies and surgical procedures as adjunct to implant placement.
36

Regeneração óssea de defeitos circunferenciais criados cirurgicamente ao redor de implantes submersos. Estudo experimental em cães /

Rossi, Fabio. January 2011 (has links)
Orientador: Daniele Botticelli / Banca: Wilson Roberto Poi / Banca: Idelmo Rangel Garcia Júnior / Banca: Márcio de Moraes / Banca: Thaís da Silveira Rodrigues / Resumo: Objetivo: descrever o processo de reparo em defeitos marginais ao redor de implantes submersos 1mm abaixo ou acima da crista óssea. Estudo experimental em cães. Material e Métodos: Em 12 cães labradores, todos os pré-molares inferiores e primeiros molares foram extraídos bilateralmente. Três meses após as extrações, foi realizada a incisão sobre o rebordo e o descolamento dos retalhos de espessura total do lado direito da mandíbula. Foram preparados dois sítios cirúrgicos para instalação de implantes, com a região marginal alargada em 5mm de diâmetro para obtenção de um gap de 0,5 mm na região mesial (defeito pequeno) e um gap de 1,25 mm na região distal (defeito grande). Os parafusos de cobertura foram colocados aos implantes e os retalhos suturados para permitir um processo de cicatrização totalmente submerso. Posteriormente, foram realizados os mesmos procedimentos experimentais no lado esquerdo da mandíbula. O momento da realização dessas cirurgias e as eutanásias foram planejados de forma a se obter biópsias com 5, 10, 20, 30 dias de pósoperatórios. Após a eutanásia, os cortes histológicos foram processados laboratorialmente para análise histomorfométrica. Resultados: Aos 30 dias pós-operatório, os defeitos ósseos apresentaram-se parcialmente preenchidos por osso neoformado em todos os espécimes. A formação óssea ocorreu originando-se a partir da base do defeito e das paredes laterais. Um maior volume de osso neoformado foi observado nos defeitos grandes quando comparado aos pequenos. A maior parte de osso neoformado nos defeitos grandes formou-se entre o décimo e vigésimo dias de pósoperatórios. Entretanto, o contorno do osso neoformado localizou-se a uma distância similar da superfície do implante (aproximadamente 0,4 mm) em ambos os tipos de defeitos, no... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: to describe the healing of marginal defects below or above one millimeter of dimension around submerged implants in a dog model. Material and Methods: In 12 Labrador dogs, all mandibular premolars and first molars were extracted bilaterally. After 3 months of healing, full-thickness flaps were elevated in the edentulous region of the right side of the mandible. Two recipient sites were prepared and the marginal 5 mm were widened to such an extent to obtain, after implant installation, a marginal gap of 0.5 mm at the mesial site (small defect) and of 1.25 mm at the distal site (large defect). Titanium healing caps were affixed to the implants and the flaps were sutured allowing a fully-submerged healing. The experimental procedures were subsequently performed in the left side of the mandible. The timing of the experiments and sacrifices were planned in such a way to obtain biopsies representing the healing after 5, 10, 20, 30 days. Ground sections were prepared and histomorphometrically analyzed. Results: The filling of the defect with newly formed bone was incomplete after one month of healing in all specimens. Bone formation occurred from the base and the lateral walls of the defects. A larger volume of new bone was formed in the large compared to the small defects. Most of the new bone at the large defect was formed between the 10 and the 20-day period of healing. After one month of healing, the outline of the newly formed bone was, however, located at a similar distance from the implant surface (about 0.4 mm) at both defect types. Only minor newly formed bone in contact with the implant, starting from the base of the defects, was seen at the large defects (about 0.8 mm) while a larger amount was detected at the small defects (about 2.2 mm). Conclusion: Marginal defects around titanium... (Complete abstract click electronic access below) / Doutor
37

Estudo in vitro das alterações na superfície do titânio comercialmente puro e da liga de titânio Ti -6Al-4V submetida a diferentes tratamentos /

Faverani, Leonardo Perez. January 2012 (has links)
Orientador: Wirley Gonçalves Assunção / Coorientador: Valentim Adelino Ricardo Barão / Banca: Idelmo Rangel Garcia Júnior / Banca: Cláudio Maldonado Pastori / Resumo: Proposição: Neste estudo nós investigamos o efeito dos peróxidos de carbamida a 16% e a 35%, peróxido de hidrogênio 35% e refrigerante de Cola, nas modificações da superfície do titânio comercialmente puro (Ti-cp) e liga Ti-6Al-4V. Materiais e Métodos: Setenta e dois discos de Ti (8 mm de diâmetro, 2 mm de espessura) foram utilizados e divididos em 18 grupos (n = 4) em função do tratamento das soluções e o tipo de Ti. Os espécimes foram mecanicamente polidos utilizando procedimentos metalográficos padrão. Os espécimes foram imersos em 3 ml de peróxido de carbamida a 16% e a 35%, em peróxido de hidrogênio 35% e ao refrigerante de Cola, 4 horas por dia (mantidos secos ou imersos em saliva artificial nas 20 horas restantes), durante 15 dias. Os espécimes do grupo controle foram imersos apenas em saliva artificial ao longo dos 15 dias. A rugosidade de superfícies e a topografia do Ti foram examinados por meio da microscopia de força atômica (AFM) e microscopia eletrônica de varredura (MEV). As modificações químicas das superfícies Ti foram avaliadas por meio da espectroscopia de energia dispersiva (EDS). Os dados foram analisados pela ANOVA de três fatores e o teste de Tukey foi utilizado como técnica post-hoc (α =.05). Resultados: Os grupos imersos em peróxido de hidrogênio 35% apresentaram a maior rugosidade (P <0,05), seguido pelos peróxidos de carbamida, com maiores valores para o Ticp, porém sem alterações quando associados ou não à saliva artificial. Estes valores foram estatisticamente superiores aos observados no início e no grupo controle. O refrigerante de Cola não alterou a rugosidade de superfície de ambos os tipos de Ti (P> 0,05). A MEV e a AFM mostraram maiores alterações... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose: In this study we investigated the effect of 16% and 35% carbamide peroxides, 35% hydrogen peroxides and cola soft drink, on the surface modifications of commercially-pure titanium (cp-Ti) and Ti-6Al-4V alloy. Materials and Methods: Seventy-two Ti discs (8-mm diameter, 2-mm thickness) were used and divided into 18 groups (n=4) as a function of solution treatments and Ti type. Samples were mechanically polished using standard metallographic procedures. Samples were immersed into 3 ml of 16% and 35% carbamide peroxides, 35% hydrogen peroxide and cola soft drink at 4 hours per day (kept dried or immersed in artificial saliva in the remaining 20 hours) during 15 days. Control samples were immersed just in artificial saliva throughout the 15 days. Ti surfaces roughness and topography were examined using atomic force microscopy (AFM) and scanning electron microscopy (SEM). The chemical modifications of Ti surfaces were evaluated through energy dispersive spectroscopy (EDS). Data were analyzed by 3-way ANOVA, Tukey's tests were further used as post-hoc techniques (α=.05). Results: Groups immersed in 35% hydrogen peroxide exhibited the greatest surface roughness (P<.05), followed by the carbamide peroxides regardless of Ti type and association or not with artificial saliva. Ticp exhibited greater surface roughness than Ti-6Al-4V alloy. These values were statistically higher than those observed at baseline and in control group. Cola soft drink did not change the surface roughness of both Ti types (P>.05). The SEM and AFM images of Ti surfaces showed higher surface changes for the samples immersed in 16% and 35% carbamide peroxides, and 35% hydrogen peroxide, with greater visible alteration for Ticp. These groups promoted the formation of crevices and pitting on the Ti surfaces. No detectable chemical... (Complete abstract click electronic access below) / Mestre
38

Efeito da deficiência de magnésio sobre o metabolismo do tecido ósseo /

Belluci, Marina Montosa. January 2012 (has links)
Resumo: O magnésio (Mg+2) é um mineral que possui um importante papel na homeostase mineral, podendo afetar diretamente a função das células ósseas e a formação da hidroxiapatita. Entretanto, até o presente momento existem poucos estudos avaliando os mecanismos relacionados à alteração do metabolismo ósseo frente à deficiência de Mg. O objetivo desse estudo foi avaliar, in vitro, o efeito da deficiência de magnésio sobre a osteoclastogênese e atividade de osteoclastos. Também foi objetivo avaliar, in vivo, o efeito da deficiência de magnésio na dieta sobre o metabolismo ósseo, doença periodontal e tecido ósseo ao redor de implantes com osseointegração estabelecida. Para o estudo in vitro, foram avaliadas células indiferenciadas da medula óssea de ossos longos e mandíbula de camundongos. As células foram cultivadas em plástico e sobre tecido ósseo, em meios de cultura com diferentes concentrações de Mg (0.8 Mm que é considerada a quantidade adequada de Mg; e meios com redução do Mg, 0.4 Mm; 0.08 Mm; e 0 Mm). Após 3 dias de cultura, foram avaliadas a viabilidade celular, a taxa de proliferação celular e a expressão gênica, por PCR, de genes relacionadas à osteoclastogênese (c-fms, RANK, DC STAMP, c-fos, TNF-α e IL-1β) e ao metabolismo do Mg (TRPM-7 e MRS2). Após 6 dias de cultura, foram avaliados os parâmetros: número de células osteoclásticas (coloração de TRACP), atividade (liberação de TRACP) e taxa de proliferação celular. Após 8 dias de cultura a atividade dos osteoclastos foi avaliada por análise de pit de reabsorção. Para o estudo in vivo, foram utilizados 30 ratos, divididos em 2 grupos: grupo controle (CTL), que recebeu dieta com conteúdo adequado de magnésio, e grupo Mg, que recebeu dieta... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Magnesium (Mg) deficiency is very common condition in the world population. This mineral has an important role on bone homeostasis. However, there has been little research regarding the mechanisms in which magnesium deficiency alters bone metabolism. Also, the understanding of the factors associated to bone metabolism is of interesting for the prognosis of oral therapies, such as on periodontal disease and on osseointegrated dental implants. The aim of this study was to evaluate, in vitro, whether Mg deficiency affects the formation and/or activity of osteoclasts. And also to evaluate, in vivo, the effect of Mg intake deficiency on bone metabolism, periodontal disease and the bone tissue around osseointegrated implants. For the in vitro study, bone marrow cells from long bone and jaw of mice were seeded on plastic and on bone in medium containing different concentrations of Mg (0.8 mM which is 100% of the normal value, 0.4, 0.08 and 0 mM). The effect of Mg deficiency was evaluated on cell viability after 3 days and proliferation rate after 3 and 6 days, as was mRNA expression of osteoclastogenesis-related genes (M-CSF, RANK, c-fos, DC STAMP, TNF-α and IL-1β) and Mg-related genes (TRPM7 and MRS2). After 6 days of incubation, the number of tartrate resistant acid phosphatase-positive multinucleated cells (TRACP+-MNCs) was determined, and the TRACP activity of the medium was measured. Osteoclastic activity was assessed at 8 days by resorption pit analysis. For the in vivo studies, 30 rats received an implant in the right tibial metaphysis. After 60 days for healing of the implants, the animals were divided into groups according to the diet received. Control group (CTL) received a standard diet with adequate... (Complete abstract click electronic access below) / Orientador: Silvana Regina Perez Orrico / Coorientador: Carlos Rossa Junior / Banca: Denise Carleto Andia / Coorientador: Vicent Everts / Banca: Juliana Rico Pires / Banca: Paulo Sergio Cerri / Banca: Joni Augusto Cirelli / Doutor
39

Estudo in vitro das alterações na superfície do titânio comercialmente puro e da liga de titânio Ti -6Al-4V submetida a diferentes tratamentos

Faverani, Leonardo Perez [UNESP] 17 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-17Bitstream added on 2014-06-13T18:51:03Z : No. of bitstreams: 1 faverani_lp_me_araca.pdf: 585353 bytes, checksum: 55ba5a6198999b7b032f65483a4c39b6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / Proposição: Neste estudo nós investigamos o efeito dos peróxidos de carbamida a 16% e a 35%, peróxido de hidrogênio 35% e refrigerante de Cola, nas modificações da superfície do titânio comercialmente puro (Ti-cp) e liga Ti-6Al-4V. Materiais e Métodos: Setenta e dois discos de Ti (8 mm de diâmetro, 2 mm de espessura) foram utilizados e divididos em 18 grupos (n = 4) em função do tratamento das soluções e o tipo de Ti. Os espécimes foram mecanicamente polidos utilizando procedimentos metalográficos padrão. Os espécimes foram imersos em 3 ml de peróxido de carbamida a 16% e a 35%, em peróxido de hidrogênio 35% e ao refrigerante de Cola, 4 horas por dia (mantidos secos ou imersos em saliva artificial nas 20 horas restantes), durante 15 dias. Os espécimes do grupo controle foram imersos apenas em saliva artificial ao longo dos 15 dias. A rugosidade de superfícies e a topografia do Ti foram examinados por meio da microscopia de força atômica (AFM) e microscopia eletrônica de varredura (MEV). As modificações químicas das superfícies Ti foram avaliadas por meio da espectroscopia de energia dispersiva (EDS). Os dados foram analisados pela ANOVA de três fatores e o teste de Tukey foi utilizado como técnica post-hoc (α =.05). Resultados: Os grupos imersos em peróxido de hidrogênio 35% apresentaram a maior rugosidade (P <0,05), seguido pelos peróxidos de carbamida, com maiores valores para o Ticp, porém sem alterações quando associados ou não à saliva artificial. Estes valores foram estatisticamente superiores aos observados no início e no grupo controle. O refrigerante de Cola não alterou a rugosidade de superfície de ambos os tipos de Ti (P> 0,05). A MEV e a AFM mostraram maiores alterações... / Purpose: In this study we investigated the effect of 16% and 35% carbamide peroxides, 35% hydrogen peroxides and cola soft drink, on the surface modifications of commercially-pure titanium (cp-Ti) and Ti-6Al-4V alloy. Materials and Methods: Seventy-two Ti discs (8-mm diameter, 2-mm thickness) were used and divided into 18 groups (n=4) as a function of solution treatments and Ti type. Samples were mechanically polished using standard metallographic procedures. Samples were immersed into 3 ml of 16% and 35% carbamide peroxides, 35% hydrogen peroxide and cola soft drink at 4 hours per day (kept dried or immersed in artificial saliva in the remaining 20 hours) during 15 days. Control samples were immersed just in artificial saliva throughout the 15 days. Ti surfaces roughness and topography were examined using atomic force microscopy (AFM) and scanning electron microscopy (SEM). The chemical modifications of Ti surfaces were evaluated through energy dispersive spectroscopy (EDS). Data were analyzed by 3-way ANOVA, Tukey’s tests were further used as post-hoc techniques (α=.05). Results: Groups immersed in 35% hydrogen peroxide exhibited the greatest surface roughness (P<.05), followed by the carbamide peroxides regardless of Ti type and association or not with artificial saliva. Ticp exhibited greater surface roughness than Ti-6Al-4V alloy. These values were statistically higher than those observed at baseline and in control group. Cola soft drink did not change the surface roughness of both Ti types (P>.05). The SEM and AFM images of Ti surfaces showed higher surface changes for the samples immersed in 16% and 35% carbamide peroxides, and 35% hydrogen peroxide, with greater visible alteration for Ticp. These groups promoted the formation of crevices and pitting on the Ti surfaces. No detectable chemical... (Complete abstract click electronic access below)
40

Influência da nicotina na osseointegração de implantes instalados em tíbias de ratos : avaliação biomecânica, histológica, histométrica e imunoistoquímica /

Faleiros, Paula Lazilha. January 2016 (has links)
Orientador: Alvaro Francisco Bosco / Coorientador: Juliano Milanezi de Almeida / Coorientador: Valdir Gouveia Garcia / Banca: Letícia Helena Theodoro / Banca: Edilson Ervolino / Banca: Marcio Zaffalon Casati / Banca: Leandro Araújo Fernandes / Resumo: Objetivo: Avaliar do ponto de vista biomecânico, histomorfométrico, histoquímico e através de marcadores imunoistoquímicos a influência da terapia com laser em baixa intensidade (LLLT) na osseointegração de implantes instalados em tíbias de ratos modificados ou não sistemicamente pela nicotina. Materiais e métodos: Um total de 120 ratos (Wistar) foi distribuído em dois grandes grupos experimentais (n = 60) submetidos a duas aplicações diárias de solução salina (Veh) ou nicotina (Nic). Após 30 dias, implantes de titânio (2.2 mm x 4 mm) foram instalados na metáfise proximal de ambas as tíbias de todos os animais. Grupos experimentais de diferentes tratamentos locais do alvéolo cirúrgico previamente a instalação do implante (n = 30) foram criados no momento da cirurgia: Veh - nenhum tratamento; Veh/LLLT - irradiação do alvéolo cirúrgico com laser em baixa intensidade; Nic - nenhum tratamento; Nic/LLLT - irradiação do alvéolo cirúrgico com laser em baixa intensidade. O laser utilizado foi o Thera Lase (InGaAlP 660 nm, modo de aplicação contínuo, em contato com a área, 35 mW, 0,14 J, 4,9 J/cm2, por 4 segundos). Dez animais de cada grupo foram eutanasiados aos 15, 30 e 60 dias pós-operatórios. As tíbias direitas foram submetidas à análise de torque reverso e posteriormente processadas para confecção de cortes histológicos descalcificados, corados por hematoxilina e eosina, vermelho picrosirius ou submetidos a reações imunoistoquímicas com os anticorpos primários policlonais: HIF-1 ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: To evaluate, from biomechanical, histomorphometric, histochemical stand point and through of immunohistochemical markers, the influence of low level laser therapy (LLLT) on the osseointegration of implants placed in the tibias of nicotine systemically modified (or not) rats. Materials and methods: A total of 120 rats (Wistar) was assigned into two major experimental groups (n = 60) underwent two-daily-applications of saline (Veh) or nicotine (Nic). After thirty days, titanium implants (2.2 mm x 4 mm) were placed in the proximal metaphysis of both tibiae from all animals. Experimental groups of different surgical alveolus local treatments prior to implant placement (n = 30) were created at the moment of the surgery: Veh - no local treatment; Veh/LLLT - irradiation of surgical alveoli with low level laser; Nic - no local treatment; Nic/LLLT - irradiation of surgical alveoli with low level laser. The laser used was Thera Lase® (InGaAIP 660 nm, in continuous mode, in contact with the area, 35 mW, 0.14 J, 4.9 J/cm2, for 4 seconds). Ten animals from each group were euthanized at 15, 30 and 60 days postoperative. The right tibiae were submitted to reverse-torque analysis and, then processing in order to prepare decalcified histological sections, stained either by hematoxylin and eosin or picrosirius red or subjected to immunohistochemical reactions with the primary polyclonal antibodies: HIF-1 α, VEGF, BMP-2, RUNX-2, OCN, ALP, RANKL, OPG and TRAP. From left tibias were p... (Complete abstract click electronic access below) / Doutor

Page generated in 0.057 seconds