• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 174
  • 56
  • 11
  • 7
  • 7
  • 7
  • 7
  • 7
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 281
  • 140
  • 134
  • 127
  • 97
  • 85
  • 76
  • 70
  • 41
  • 39
  • 35
  • 31
  • 29
  • 28
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Das Einwachsverhalten von zylindrischen Implantaten aus einer porösen Ti-6Al-4V-Legierung in die Femurkondyle des Kaninchens / The ingrowth behavior of cylindrical implants made of a porous Ti-6Al-4V alloy in the femoral condyle of the rabbit

Frosch, Alice 10 December 2020 (has links)
No description available.
102

Bone regeneration in novel porous titanium implants

Khouja, Naseeba, 1981- January 2010 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The objective of this study was to evaluate the in vivo performance of the novel press-fit dental implant fabricated via electron beam melting (EBM, Southern Methodist Univ.) and compare it to a commercially-available porous-coated press-fit dental implant (Endopore, Innova Corp.). Twelve cylindrical shaped implants 3 mm in diameter x 5 mm long were made by EBM (Southern Methodist Univ.) using Ti6Al4V ELI alloy. Twelve commercial implants (Endopore, Innova Corp.) of the same geometry were used as controls. Samples were implanted in rabbit tibia and retrieved six weeks postoperatively. Six specimens from each implant type were embedded undecalcified, sectioned, and stained with toluidine blue (Sigma) for histomorphometry analysis. Bone-to-implant contact (BIC) was measured. On the six remaining samples from each implant type, the mechanical properties were evaluated by pushout test on a material testing machine. The samples were loaded at a loading rate of 1 mm/min. The pushout strength was measured and the apparent shear stiffness was calculated. The results were analyzed with a paired-t test. The histology shows osteointegration of surrounding bone with both implant types. Bone was found to grow into the porous space between the beads. Both the Endopore (Innova Corp.) and the EBM (Southern Methodist Univ.) showed similar BIC. The mean BIC for the Endopore (Innova Corp.) and EBM (Southern Methodist Univ.) implant were 35 ± 6% and 32 ± 9%, respectively. It failed to reach statistical significance (p > 0.05). The peak pushout force for Endopore (Innova Corp.) and EBM (Southern Methodist Univ.) implants were 198.80 ± 61.29 N and 243.21 ± 69.75 N, respectively. The apparent shear stiffness between bone and implant for the Endopore (Innova Corp.) and EBM (Southern Methodist Univ.) implants were 577.36 ± 129.99 N/mm; and 584.48 ± 146.63 N/mm, respectively. Neither the peak pushout force nor the apparent shear stiffness of the implants was statistically different between the two groups (p > 0.05). The results suggest that the implants manufactured by EBM (Southern Methodist Univ.) perform equally well as the commercial implant Endopore (Innova Corp.) in this current animal model.
103

Avaliação da resposta do tecido ósseo tipo IV a implantes osseointegráveis de titânio com diferentes tratamentos de superfície / Evaluation of type IV bone tissue response to titanium implants with different surface treatments.

Freitas, Gileade Pereira 26 June 2014 (has links)
As alterações de superfície dos implantes de titânio (Ti) influenciam funções celulares e formação de tecido adjacente aos mesmos, mas é controverso se tais alterações trariam vantagens quando esses implantes fossem colocados em tecido ósseo de baixa qualidade. O objetivo deste estudo foi avaliar a resposta do tecido ósseo de baixa qualidade (tipo IV) a implantes de Ti com diferentes tratamentos de superfície. Para isso, implantes de Ti com superfície nanotexturizada (Ti-Nano), microtexturizada (Ti-Porous) e sem tratamento de superfície (Ti-Usinado) foram implantados em tíbias de coelhos. Após duas e seis semanas, o tecido ósseo formado ao redor dos implantes foi avaliado em cortes histológicos por desgaste e histomorfometricamente foram avaliados: a porcentagem de contato ossoimplante (BIC), porcentagem de área de osso mineralizado formado entre as espiras do implante (BABT), porcentagem da área de osso formada na área espelho (BAMA). Vários outros parâmetros morfométricos foram avaliados a partir de imagens e reconstruções tridimensionais obtidos por microtomografia. Ao final de seis semanas, foi avaliado o torque de remoção. Os resultados foram submetidos à análise de variância (ANOVA) com dois fatores de variação (tratamento de superfície e tempo de implantação) seguido do teste de Tukey (p≤0,05). Apesar de algumas diferenças estatisticamente significantes para alguns dos parâmetros morfométricos, tais diferenças não são biologicamente importantes para que pudessem ser atribuídas aos tratamentos de superfície. Tanto que, histologicamente não se observou diferença nos padrões de formação óssea ou tipo de osso formado que pudesse ser associado aos tratamentos de superfície e o torque de remoção também não foi afetado pelos tratamentos. Em conclusão, esses resultados mostraram que os tratamentos de superfície, embora sejam na escala micrométrica ou nanométrica, não induzem repostas do tecido ósseo tipo IV diferentes daquelas induzidas por superfícies sem tratamento. / Some alterations in titanium (Ti) implant surfaces influence cell functions and tissue formation in areas adjacent to the implants, but it is controversial whether these changes would bring advantages when these implants were placed in bone of poor quality. The aim of this study was to evaluate the response of poor quality bone tissue (type IV) to Ti implants with different surface treatments. For this, Ti implants with nanotextured surface (Ti-Nano), microtextured (Ti-Porous) and without surface treatment (Ti-Machined) were implanted into tibias of rabbits. After two and six weeks, the bone tissue around the implants was assessed in undecalcified histological sections and histomorphometrical analysis to evaluate: the percentage of bone-implant contact (BIC), percentage of the area of mineralized bone formed between threads (BABT), the percentage area of bone formed in the mirror area (BAMA). Several other morphometric parameters were evaluated from images and three-dimensional reconstructions obtained by microtomography. At the end of six weeks the removal torque was evaluated. The results were subjected to analysis of variance (ANOVA) with two factors of variation (surface treatment and time) followed by Tukey test (p≤0.05). Despite some statistically significant differences for some of the morphometric parameters, such differences are not biologically important and they could not be attributed to the surface treatments. In keeping with this, histological analysis failed to show any difference in bone formation that could be associated to the surface treatments and removal torque was not affected by treatments either. In conclusion, these results showed that the surface treatments, irrespective of being on the micrometer or nanometer scale, do not induce responses of type IV bone tissue different from those induced by untreated surfaces.
104

Implantes cerâmicos e metálicos - caracterização da osteointegração por imuno-histoquímica, lectina-histoquímica e marcadores fluorescentes / Ceramic and metallic implants - osseointegration characterization by immunohistochemistry, lectinhistochemistry and fluorescent markers

Violin, Kalan Bastos 24 August 2015 (has links)
Biomateriais, cerâmicos ou metálicos, para emprego em tecido ósseo, são importantes ferramentas na medicina regenerativa com intuito de reparar, restaurar, restituir, sustentar, tratar e substituir tecido lesionado. A análise da resposta biológica aos biomateriais é um grande desafio, considerando os aspectos inerentes do tecido ósseo mineralizado e as características físicas dos biomateriais. A compreensão do comportamento celular envolvido nesse conjunto tem o intuito de desenvolver biomateriais mais aptos e adequados ao tecido ósseo o qual ele é destinado. O objetivo deste estudo foi avaliar a osteointegração de implantes cerâmicos e metálicos após ensaio in vivo, por meio de técnicas histoquímicas com colorações de Giemsa-Eosina (GE), Hematoxilina-Eosina (HE), Tricrômico de Masson-Goldner (MG), Tricrômico de Masson (TM), Tricrômico de Gomori (GO) e Picrossírus (PS), Azul de Toluidina (AT) além de técnicas imunohistoquímica (IHQ), lectina-histoquímica (LHQ) e marcadores fluorescentes. Implantes cerâmicos à base de fosfatos de cálcio: hidroxiapatita (HAp), β-fosfato tricálcico (β-TCP) e mistura dos dois (BCP) 1:1 em peso, foram produzidos por gelcasting de espuma e pela inovadora técnica da bola de neve. Os implantes à base de titânio comercialmente puro (Ticp) e da Liga Ti-13Nb-13Zr (Liga) foram produzidos por metalurgia do pó; sendo macroporosos, com a adição de diferentes polímeros naturais, ou microporosos, com elevadas densidades, submetidos a diferentes tratamentos de superfície. A avaliação da osteointegração foi realizada em tíbia de coelhos após períodos de reparação, em conjuntos osso-implante: não-descalcificados e descalcificados. Na análise histológica por microscopia óptica com colorações histoquímicas, os conjuntos apresentaram crescimento ósseo com osteointegração em todos os implantes. A análise por fluorescência mostrou as fases e áreas marcadas de acordo com o período de aplicação do marcador, indicando intenso remodelamento ósseo em todo o osso, o crescimento ósseo no interior dos poros e ao redor dos implantes para os marcadores tetraciclina e calceína. Com a análise de IHQ foram avaliados os marcadores para osteopontina (OP), osteonectina (ON) e osteocalcina (OC), e com LHQ foram avaliadas 5 lectinas. O melhor marcador por IHQ foi para OP, havendo correlação entre a marcação com WGA pela LHQ e OP pela IHQ. A técnica de LHQ foi bem sucedida em criar perfis de comparação entre os biomateriais. A maior marcação por RCA-1 para todos os implantes cerâmicos e metálicos, indicam que esta é um promissor marcador para diferenciação em estudos de osteointegração, bem como a marcação por sWGA e PNA nos implantes de Liga. / The use of biomaterials in bone, whether ceramic or metallic, are important tools for regenerative medicine aiming to repair, restore, restitute, support, treat and substitute damaged tissue. The evaluation of biological response towards biomaterials is a big challenge considering the inherent aspects of mineralized bone tissue and physical characteristics of biomaterials. The understanding of the cellular behavior involved will propitiate the development of more fit and adequate biomaterials to the targeted bone. The objective of this study was to evaluate the osseointegration of ceramic and metallic implants after in vivo testing on bone, with histochemical staining techniques as Giemsa-Eosin (GE), Hematoxylin-Eosin (HE), Masson-Goldners Trichrome (MG), Massons Trichrome (MT), Gomoris Trichrome (GT), Picrosirius Red (PS), Toluidine Blue (TB), besides Immunohistochemistry (IHC), Lectinhistochemistry (LHC) and Fluorescent labeling. The ceramic implants were produced using calcium phosphates: hydroxyapatite (HAp), β-tricalcium phosphate (β-TCP) and their biphasic mixture (BCP) 1:1 by weight, as ceramic foam by gelcasting or as ceramic spheres obtained by the innovative Snowballing technique. The metallic implants were produced using commercially pure titanium (cpTi) and alloy Ti-13Nb-13Zr (Alloy) by powder metallurgy, using natural polymers as additives to achieve macroporosity and microporous without additives and different surface treatments. The osseointegration evaluation was performed on implanted tibia bone of New Zealand White rabbits after repair period in bone-implant samples either decalcified or undecalcified. Histological analysis of stained slides with optical microscopy showed samples with bone ingrowth and osteointegration on all implants. The Fluorescent analysis evidenced the bone growth phases and areas according to each marker injection period. Intense remodeling process throughout the bone, bone ingrowth inside the pores and surrounding the implants was observed with the markers tetracycline and calcein. The IHC analysis was performed using markers for osteopontin (OP), osteocalcin (OC) and osteonectin (ON), and LHC analysis using five lectins. The best marker by IHC was OP; with correlation between the result of lectin WGA and the antibody for OP. The LHC technique was successful creating profiles for comparison between biomaterials. The results of RCA-1 for all ceramic and metallic implants indicates that this is a promising marker for differentiation at osseointegration studies, as well as the results of sWGA and PNA for Alloy implants.
105

Implantes porosos à base de titânio, avaliação in vitro e in vivo / Titanium based porous implants, in vitro and in vivo evaluation

Goia, Tamiye Simone 14 February 2013 (has links)
O desenvolvimento de biomateriais com estrutura porosa visa permitir uma boa ancoragem biológica através do crescimento do tecido ósseo no interior dos poros, além de no caso de algumas ligas de titânio, proporcionar valores de módulo elástico semelhantes ao do osso, prevenindo assim o insucesso por reabsorção óssea na interface com o implante. O objetivo deste estudo foi avaliar o processamento de implantes porosos à base de titânio produzidos por metalurgia do pó, utilizando polímeros naturais como aditivos (albumina, amidos de arroz, batata, milho e a gelatina), e analisar a osteointegração desses implantes por ensaio in vivo. Foram obtidas, amostras de titânio comercialmente puro (Ticp) e da Liga Ti-13Nb-13Zr pelos processos de space-holder e suspensão; os polímeros naturais foram removidos termicamente (350°C/1h) previamente a sinterização (1300°C/1h e 1300°C/3h, respectivamente). As metodologias de processamento utilizando aditivos de baixo custo propiciaram a obtenção de implantes metálicos porosos de maneira simplificada, com porosidades diferenciadas, boa homogeneidade estrutural, grau de porosidade adequado (entre 40% e 60%), distribuição e tamanho dos poros conforme o polímero natural formador. Na caracterização biológica, o teste in vitro de citotoxicidade validou a utilização dos implantes para a realização do teste in vivo. A avaliação da osteointegração foi realizada em coelhos da raça New Zealand em períodos de 49 dias. Na análise histológica por microscopia eletrônica de varredura e fluorescência, foram obtidos os resultados quantitativos e qualitativos da osteointegração, com crescimento ósseo em todos os implantes, apresentando osteocondutividade. Os melhores resultados ocorreram em implantes com porosidade homogênea, e com tamanho médio de poros entre 100 e 200 μm. Assim, os materiais porosos de titânio e da liga Ti-13Nb-13Zr produzidos com os polímeros naturais (amido de arroz, amido de batata, amido de milho, gelatina e albumina), permitiram a nutrição e manutenção necessárias para a sobrevivência das células, comprovando a osteointegração e osteocondução dos implantes desenvolvidos. / The development of biomaterials with porous structure, seeks to allow a good biological anchorage through bone tissue ingrowth within the pores, besides to propitiate elastic modulus values similar to bone, thus preventing the failure by bone resorption, on implants interface. The goals of this study was to evaluate the processing of titanium based porous implants by powder metallurgy (PM), using natural polymers as additive (rice, potato and corn starches, albumin and gelatin), and evaluate these implants osseointegration by in vivo assay. Samples were obtained of commercially pure titanium (cpTi) and Ti-13Nb-13Zr alloy by space-holder and suspension techniques; the natural polymers were removed by thermal treatment (350C/1h) prior to sintering (1300C/1h and 1300C/3h respectively). The processing methodologies using low cost additives propitiate the production of porous metallic implants in a simplified manner, with differentiated porosities, good structural homogeneity, proper porosity degree (between 40% and 60%), distribution and pore size as the related natural polymer. The biological characterization was first performed in vitro with a cytotoxicity test, which allowed the use of implants in vivo. The osseointegration evaluation was performed in New Zealand White rabbits for 49 days period. Histological analyses with scanning electron microscopy and fluorescence microscopy were obtained quantitative and qualitative results of osseointegration, with bone growth in all implants, presenting osteoconductivity. The best results were in implants with homogenous porosity and with mean pore size between 100 and 200 μm. Thus, titanium and Ti-13Nb-13Zr alloy porous materials produced with natural polymers (rice, potato and corn starches, albumin and gelatin), allowed the nutrition and nourishing needed to bone cells survival, proving the osseointegration and osteoconduction features of developed implants.
106

Avaliação de dispositivo para viabilização de análise de frequência de ressonância em implantes dentários em ovelhas /  

Dorce, Cristiane Marques 13 April 2018 (has links)
Afirmação do problema. Estudos experimentais em animais são utilizados para avaliar previamente o resultado de pesquisas e sua necessidade de serem realizadas em humanos. Estudos em animais são fundamentais na implantodontia para que haja uma melhor compreensão da osseointegração. Durante o processo de execução de pesquisas nesse tipo de estudo, algumas dificuldades relacionadas ao manuseio, custos de manutenção e bem-estar dos animais tendem a dificultar o seu desenvolvimento. Finalidade. Esse estudo tem como objetivo, testar um novo dispositivo acoplado sobre o implante, para que possa atuar como uma extensão do mesmo, facilitando a realização da Análise de Frequência de Ressonância durante o processo de osseointegração permitindo que implantes instalados em ovelhas em diferentes períodos, possam ser reabertos sem que haja a necessidade de etapas cirúrgicas para a reabertura durante a realização de testes. Material e métodos. Foram utilizadas 4 ovelhas, sendo uma do Grupo Controle (GC) e 3 do Grupo Teste (GT). Cada animal recebeu oito implantes localizados próximos ao ângulo da mandíbula, sendo quatro do lado esquerdo e quatro do lado direito, totalizando, 32 implantes cone-morse Acqua® de 3,5 de diâmetro por 8,5mm de comprimento da empresa Neodent® que foram avaliados pela análise de frequência de ressonância com a medição do ISQ (Quociente de Estabilidade do Implante) utilizando um transdutor (SmartPeg) expressos numa escala de 0 a 100. Para o Grupo Controle (GC) as medições de ISQ foram realizadas pelo método convencional, onde o SmartPeg foi acoplado diretamente sobre a plataforma do implante. Já no Grupo Teste (GT) o dispositivo estudado, foi acoplado ao implante para que pudesse ser realizada a medição. Os períodos estudados foram: imediatamente após a cirurgia e com quatro semanas de osseointegração. Para a análise estatística foram empregados os testes de Wilcoxon e Man-Whitney com a probabilidade de 5% (p<0.05). Resultados. As médias obtidas no GC foram 50,47 imediatamente após cirurgia e 65,68 após 4 semana, enquanto que no GT foram 34,74 e 34,81, respectivamente. Comparando a diferença entre os grupos nas médias de ISQ imediatas e após quatro semanas, houve diferença significativa com p= 0.0321 e p= 0.0027, respectivamente, demonstrando que os resultados no GT nos dois períodos não foram equivalentes quando comparados ao GC. Conclusão. Os resultados demonstraram que o grupo teste, apesar de trazer benefícios em relação ao manuseio dos animais, não apresentou benefícios com relação à eficiência na leitura do ISQ, quando comparado ao método convencional. / Statement of the problem. Experimental studies in animals are used to pre-evaluate the results of research and their need to be performed in humans. Animal studies are fundamental in implantology so that there is a better understanding of osseointegration. During the execution of research in this type of study, some difficulties related to handling, maintenance costs and animal welfare tend to hinder its development. Purpose. This study aims to test a new device coupled on the implant, so that it can act as an extension of the same, facilitating the performance of the Resonance Frequency Analysis during the osseointegration process allowing implants installed in different periods of time, can be reopened without the need for surgical steps for reopening during testing. Material and methods. Four sheep were used, one being from the Control Group (GC) and 3 from the Test Group (GT). Each animal received eight implants located near the angle of the mandible, four on the left side and four on the right side, totaling 32 Acqua® 3.5 mm diameter 8.5 mm long implants of the company Neodent® that were evaluated by the resonance frequency analysis with the ISQ (Implant Stability Ratio) measurement using a transducer (SmartPeg) expressed on a scale of 0 to 100. For the Control Group (GC) the ISQ measurements were performed by the conventional method, where the SmartPeg was attached directly onto the implant platform. In the Test Group (GT) the studied device was attached to the implant so that the measurement could be performed. The periods studied were: immediately after surgery and four weeks of osseointegration. For the statistical analysis Wilcoxon and Man-Whitney tests were used, with a probability of 5% (p <0.05). Results. The averages obtained in the CG were 50.47 immediately after surgery and 65.68 after 4 weeks, while in the GT were 34.74 and 34.81, respectively. Comparing the difference between the groups in the means of immediate SAI and after four weeks, there was a significant difference with p = 0.0321 and p = 0.0027, respectively, demonstrating that the results in the WG in the two periods were not equivalent when compared to the CG. Conclusion. The results showed that the test group, despite having benefits in relation to the handling of the animals, did not present benefits in relation to the efficiency of the ISQ reading when compared to the conventional method.
107

Implantes de zircônia reforçada com ítria (Y-TZP): avaliação histomorfométrica / Y-TZP dental implants: histomorfometry analysis

Martins, Renato 14 November 2013 (has links)
O objetivo do trabalho foi avaliar in vivo a osseointegração de implantes produzidos em zircônia reforçada com ítria (Y-TZP) e compará-los com o implante de titânio usinado e com o de superfície jateada com brushita. Para tanto, nas tíbias de 20 coelhos machos (n=10) e fêmeas (n=10) foram implantadas em uma das tíbias o implante Y-TZP (GE-1, n=10 implantes) e na outra tíbia o titânio usinado (GC, n=5 implantes) ou jateado com brushita (GE-2, n=5 implantes). Os animais receberam marcadores ósseos fluorescentes, tetraciclina (14 e 21 dias), alizarina (28 e 35 dias) e calceína (42 e 49 dias) após a cirurgia de implantação. Ao final de 56 dias, a região dos implantes foi coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados. Nas imagens obtidas no microscópio confocal foi avaliado o percentual de área para cada marcador. Nos cortes corados pelo azul de toluidina foi avaliado morfologicamente a qualidade do tecido ósseo formado e a existência de interposição de tecido conjuntivo entre osso e implante, e morfometricamente determinado o percentual de contato osso-implante (BIC) e o percentual de tecido ósseo próximo à superfície do implante (BA). Os resultados mostraram que, não houve diferenças estatisticamente significantes entre machos e fêmeas quanto aos parâmetros avaliados. Com relação aos grupos, GE-1 e GC apresentaram cortical óssea remanescente íntegra e formação de um tecido ósseo maduro/lamelar na superfície dos implantes. No GE-2 ocorreu intensa reabsorção da cortical óssea pre-existente próxima ao implante e extensa formação óssea mais imatura em relação aos observados no GE-1 e GC. Essa intensa reabsorção e extensa formação óssea fez com que o percentual de área dos marcadores fluorescentes fosse em média 0,73 vezes maior no GE-2 em relação aos grupos GE-1 e GC. Com relação ao BIC não houve diferença entre os grupos, sendo em média de 47,8%, porém, o BA no grupo GC (66,2%) foi 0,33 vezes maior em relação ao GE-1(51,6%) e GE-2 (48,2%). No modelo utilizado o implante Y-TZP apresentou osseointegração similar ao titânio usinado e superior ao jateada com brushita, podendo ser considerado uma alternativa para substituir o implante titânio quando a estética esta envolvida. / The aim of this work was evaluate in vivo the osseointegration of implants produced with yttria stabilized zirconia (Y-TZP) and compare it with machined titanium implant and sandblasted surface with brushita titanium. Therefore, on the tibia of 20 rabbits males (n=10) and female (n=10) were implanted in one of the tibias the implant Y-TZP (GE-1, n=10 implants) and on the other tibia the machined titanium (GC, n=5 implants) or sandblasted surface with brushita titanium (GE-2, n=5 implants). The animals received fluorescent bone markers, tetracycline (14th and 21th days), alizarin (28th and 35th days) and calcein (42th and 49th days). At the end of 56 days, the implants regions were collected and histomorphometrically processed to obtain tissue sections not demineralized. On images obtained from confocal microscopy was evaluated the percentage of area for each bone markers. On slides stained with toluidine blue was measured morphologically the quality of formed bone tissue and the existence of interposition of connective tissue between bone and implant, and was morphometrically determined the percentage of bone-implant contact (BIC) and the percentage of bone tissue next to the implant surface (BA). The results showed that there were no statistically significant differences between male and female regarding to evaluated parameters. Concerning to the groups, GE-1 and GC exhibited wholesome remaining cortical bone and formation of mature/lamellar bone tissue on implants surface. In GE-2 ocurred intense reabsorption of preexisting cortical bone next to the implant and extensive bone formation more immature than GE-1 and GC. This intense reabsorption and extensive bone formation made the GE-2 area percentage for fluorescent markers 0.73 times higher on average when compared to GE-1 and GC. About the BIC, there were no differences between the groups, with an average of 47.8%, however, the BA on GC group (66.2%) was 0.33 higher compared to GE-1 (51.6%) and GE-2 (48.2%). In the model used, the Y-TZP implant exhibited osseointegration suchlike machined titanium and better than sandblasted surface with brushita titanium, being considered an alternative to replace the titanium implant when aesthetics is involved.
108

Evolução dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial: revisão sistemática / Evolution of retention, fixation and anchorage extraoral in maxillofacial rehabilitation systems: a systematic review

Cobein, Marcus Vinicius 02 July 2014 (has links)
Introdução: A utilização de próteses bucomaxilofaciais é de extrema importância para a reintegração no convívio social dos pacientes acometidos de deformidades congênitas ou adquiridas. Tendo em vista os avanços dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial realizou-se revisão sistemática. Objetivos: verificar a evolução das retenções das próteses bucomaxilofaciais comparando os sistemas osseointegrados, aos sistemas não osseointegrados, analisando algumas variáveis como: taxa de sobrevivência dos implantes ao longo do tempo, idade média dos pacientes, etiologia do defeito facial e sitio dos sistemas de retenção relacionado ao tipo de prótese, em formato de revisão sistemática. Métodos: Realizou-se busca bibliográfica nas bases de dados PubMed e SCOPUS, após elaboração de estratégias de busca, obteve-se 2630 artigos onde foram analisados títulos, resumos e eliminadas duplicidades. Resultados: Obteve-se 25 artigos pré-selecionados que passaram pelos critérios de inclusão e exclusão sendo eleitos 13 artigos para a revisão sistemática. Conclusão: As próteses retidas por implantes superam os sistemas convencionais. A perda dos implantes foi muito pequena nos estudos analisados, apesar do tempo de acompanhamento ser relativamente curto e dos protocolos distintos de tratamento. A idade adulta entre a quarta e quinta década de vida foi a de maior prevalência. A etiologia mais incidente são as neoplasias. Os sistemas osseointegrados fixados por implantes por retenção barra clipe se localizam mais na região auricular e retenção magnética nas regiões nasal e orbital. Os sistemas não osseointegrados, a retenção anatômica é mais utilizada na região ocular, retenção mecânica na região orbital e o uso da retenção por adesivos nas regiões nasal e orbital. / Introduction: The use of maxillofacial prostheses is the most importance for reintegration into social life of patients suffering from congenital or acquired deformities. Given the advances in retention, fixation and extraoral anchorage systems in maxillofacial rehabilitation got systematic review. Objectives: To observe the evolution of the retentions of maxillofacial prostheses comparing osseointegrated systems, non osseointegrated systems, analyzing some variables such as survival rate of implants over time, mean patient age, etiology of facial defect and place restraint systems related kind of prosthesis, in a systematic review format. Methods: We performed a literature search in PubMed and SCOPUS database, after preparation of search strategies, we obtained 2630 articles where were checking titles, abstracts and eliminated duplicates were analyzed. Results: We obtained 25 pre-selected articles that passed the criteria for inclusion and exclusion being elected 13 articles for systematic review. Conclusion: The dentures retained by implants outperform conventional systems. The loss of the implants was very small in the analyzed studies, although the follow-up time is relatively short and the different treatment protocols. Between the fourth and fifth ages of life was the most prevalent. The most frequent etiology are neoplasms. Osseointegrated systems for fixed for implants retention bar clip are located more auricular and magnetic retention in the regions nasal and orbital. Non osseointegrated systems, anatomical retention is most commonly used in the ocular region, mechanical retention in orbital region and the use of adhesives for retention in the regions nasal and orbital.
109

Estudo comparativo da interação celular entre quatro tipos de implantes dentários / Comparative study of cellular interactions between four types of dental implants

Alves, Fabiana Ferreira 26 February 2015 (has links)
O tratamento de superfície dos implantes dentários é um critério importante para a osseointegração. Considerando a variedade de modificações das superfícies encontradas, estas podem acelerar ou melhorar o processo de osseointegração. Para tanto foram estudadas as características da composição química e a rugosidade, a partir das quais foram encontradas diferentes respostas celulares em estudos comparativos in vitro. O objetivo deste estudo foi comparar a adesão e o crescimento dos OSTEO-1 em implantes dentários com diferentes tratamentos de superfície. Foram utilizados quatro tipos de implantes dentários comercialmente disponíveis, com os seguintes tratamentos de superfície: (A) jateamento e condicionamento ácido com revestimento de fosfato e cálcio (CaP); (B) duplo condicionamento ácido; (C) condicionamento ácido; (D) oxidação anódica. Os implantes de mesmo tamanho foram fixados com dispositivo biocompatível no fundo dos poços das placas de cultura de 12 poços e cobertas com meio de cultura de células. Os OSTEO-1 foram colocados no corpo do implante. Nos períodos de 24, 48 e 72 horas mais tarde, as culturas foram submetidas ao ensaio de redução de MTT para avaliar a viabilidade celular. Os dados foram utilizados para analisar a adesão celular (24h) e para obter as curvas de crescimento das células (24, 48 e 72h). Os experimentos foram realizados em triplicata. Os dados foram comparados por ANOVA, complementado pelo teste de Tukey (p <0,05). Os OSTEO-1 aderiram ao corpo de todos os tipos de implantes testados. A maior taxa de crescimento celular foi observada em culturas semeadas sobre tratamento de superfície A. O menor crescimento celular foi apresentado por culturas semeadas no tratamento de superfície D (p <0,05). Com base nesta investigação in vitro é possível concluir que todos os implantes dentários testados, independentemente do tratamento de superfície, não são citotóxicos para os OSTEO-1. No entanto, as características físico-químicas do tipo de tratamento de superfície dos implantes dentários influencia o crescimento celular. A superfície A pareceu ter o comportamento mais compatível com os OSTEO-1, uma vez que promoveu mais crescimento celular. / The surface treatment of dental implants is a major feature for osseointegration. The variety of surface modifications found may be speed up or enhance the osseointegration process. In much was studied the chemical composition and characteristics of roughness, from which found different cellular responses in comparative studies in vitro.The aim of this study was to compare the adhesion and growth of osteoblast-like cells in response to dental implants characterized by different superficial treatments. Four types of dental implants with different superficial treatments were used. The commercially available implants presented the following superficial characteristics: (A) sandblasted with acid-etched and calcium phosphates (CaP) coating; (B) double acid-etched; (C) anodized, or (D) acid-etched. The implants of the same size (n= 3 per group/experimental time) were fixed with a biocompatible device on the bottom of the wells of 12 wells cell culture plates and covered with cell culture medium. Osteoblast-like cells (Osteo 1 cell line) were plated on the top of the implants (5x104 cells/implant). Twenty-four, 48 and 72 hours later, the cultures were submitted to the MTT reduction assay to assess cell viabilities. Data was used for analyze cell adhesion (24 h) and to obtain cell growth curves ( 24, 48 and 72 h). The experiments were done in triplicate. Data were compared by ANOVA complemented by the Tukey\'s test (p<0.05). Osteoblast-like cells adhered on the top of all types of implants tested. The highest cell growth was observed in cultures plated on the top of sandblasted with acid-etched and CaP coating surfaces. The smallest cell growth was presented by cultures plated on double acid-etched surfaces (p < 0.05). Based on this in vitro investigation, it is possible to conclude that all dental implants tested irrespective to the surface treatment, are non-cytotoxic for osteoblast-like cells. However, the physicochemical chacteristics of the type of dental implants surface treatment influences the cell growth. In fact, the surface treated by sandblasting with acid-etched and CaP coating seemed to the most compatible with osteoblast-like cell biology, once it promoted the highest cell growth.
110

Implantes porosos à base de titânio, avaliação in vitro e in vivo / Titanium based porous implants, in vitro and in vivo evaluation

Tamiye Simone Goia 14 February 2013 (has links)
O desenvolvimento de biomateriais com estrutura porosa visa permitir uma boa ancoragem biológica através do crescimento do tecido ósseo no interior dos poros, além de no caso de algumas ligas de titânio, proporcionar valores de módulo elástico semelhantes ao do osso, prevenindo assim o insucesso por reabsorção óssea na interface com o implante. O objetivo deste estudo foi avaliar o processamento de implantes porosos à base de titânio produzidos por metalurgia do pó, utilizando polímeros naturais como aditivos (albumina, amidos de arroz, batata, milho e a gelatina), e analisar a osteointegração desses implantes por ensaio in vivo. Foram obtidas, amostras de titânio comercialmente puro (Ticp) e da Liga Ti-13Nb-13Zr pelos processos de space-holder e suspensão; os polímeros naturais foram removidos termicamente (350°C/1h) previamente a sinterização (1300°C/1h e 1300°C/3h, respectivamente). As metodologias de processamento utilizando aditivos de baixo custo propiciaram a obtenção de implantes metálicos porosos de maneira simplificada, com porosidades diferenciadas, boa homogeneidade estrutural, grau de porosidade adequado (entre 40% e 60%), distribuição e tamanho dos poros conforme o polímero natural formador. Na caracterização biológica, o teste in vitro de citotoxicidade validou a utilização dos implantes para a realização do teste in vivo. A avaliação da osteointegração foi realizada em coelhos da raça New Zealand em períodos de 49 dias. Na análise histológica por microscopia eletrônica de varredura e fluorescência, foram obtidos os resultados quantitativos e qualitativos da osteointegração, com crescimento ósseo em todos os implantes, apresentando osteocondutividade. Os melhores resultados ocorreram em implantes com porosidade homogênea, e com tamanho médio de poros entre 100 e 200 &mu;m. Assim, os materiais porosos de titânio e da liga Ti-13Nb-13Zr produzidos com os polímeros naturais (amido de arroz, amido de batata, amido de milho, gelatina e albumina), permitiram a nutrição e manutenção necessárias para a sobrevivência das células, comprovando a osteointegração e osteocondução dos implantes desenvolvidos. / The development of biomaterials with porous structure, seeks to allow a good biological anchorage through bone tissue ingrowth within the pores, besides to propitiate elastic modulus values similar to bone, thus preventing the failure by bone resorption, on implants interface. The goals of this study was to evaluate the processing of titanium based porous implants by powder metallurgy (PM), using natural polymers as additive (rice, potato and corn starches, albumin and gelatin), and evaluate these implants osseointegration by in vivo assay. Samples were obtained of commercially pure titanium (cpTi) and Ti-13Nb-13Zr alloy by space-holder and suspension techniques; the natural polymers were removed by thermal treatment (350C/1h) prior to sintering (1300C/1h and 1300C/3h respectively). The processing methodologies using low cost additives propitiate the production of porous metallic implants in a simplified manner, with differentiated porosities, good structural homogeneity, proper porosity degree (between 40% and 60%), distribution and pore size as the related natural polymer. The biological characterization was first performed in vitro with a cytotoxicity test, which allowed the use of implants in vivo. The osseointegration evaluation was performed in New Zealand White rabbits for 49 days period. Histological analyses with scanning electron microscopy and fluorescence microscopy were obtained quantitative and qualitative results of osseointegration, with bone growth in all implants, presenting osteoconductivity. The best results were in implants with homogenous porosity and with mean pore size between 100 and 200 &mu;m. Thus, titanium and Ti-13Nb-13Zr alloy porous materials produced with natural polymers (rice, potato and corn starches, albumin and gelatin), allowed the nutrition and nourishing needed to bone cells survival, proving the osseointegration and osteoconduction features of developed implants.

Page generated in 0.1279 seconds