• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 6
  • 6
  • 6
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação do máximo déficit acumulado de oxigênio de nadadores por meio da técnica de retro extrapolação

Campos, Eduardo Zapaterra [UNESP] 15 July 2015 (has links) (PDF)
Made available in DSpace on 2016-01-13T13:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-15. Added 1 bitstream(s) on 2016-01-13T13:33:28Z : No. of bitstreams: 1 000855952.pdf: 1890967 bytes, checksum: a328487391f3e5f64c37aac8694f8b12 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Devido à necessidade de otimização dos métodos de determinação da capacidade anaeróbia, o objetivo da presente tese de doutorado foi validar a avaliação do déficit acumulado de oxigênio (AOD) por meio da técnica de retro extrapolação (AODRED). Para isso, 25 nadadores foram avaliados e quatro trabalhos foram desenvolvidos. O primeiro trabalho objetivou comparar o VO2Pico e a vVO2Pico de nadadores obtidos após esforço máximo de 400 m e teste incremental em nado livre. Onze nadadores realizaram esforço máximo de 400m e protocolo incremental para determinar ambas variáveis. Apesar de nenhuma diferença entre VO2Pico (3.86 ± 0.85 L∙min-1 vs. 4.09 ± 0.93 L∙min-1), a vVO2Pico (1.39 ± 0.12 m∙s-1 vs. 1.34 ± 0.13 m∙s-1) foi superior durante teste incremental. O segundo trabalho objetivou comparar o AODRED (i.e. soma dos metabolismos lático e alático) com o AOD após esforço máximo de 400m. Para isso seis atletas foram submetidos à quatro exercícios submáximos e um esforço máximo de 400m. O AOD foi considerado a diferença entre a demanda teórica (DT) e a contribuição aeróbia (Aer), enquanto o AODRED foi avaliado pela soma dos metabolismos anaeróbios. Nenhuma diferença entre AOD (3.29 ± 1.34 LO2) e AODRED (3.24 ± 1.56 L O2), correlações significantes (r = 0.95) e baixo erro médio de estimativa (0.04 L) foram encontrados entre as metodologias. Haja vista que nenhuma diferença foi encontrada, o terceiro estudo objetivou verificar a possibilidade de se estimar a Aer apenas pelo uso do AODRED. Seis nadadores foram submetidos à um esforço máximo de 400m com snórquel. A Aer estimada pela demanda retangular (i.e. VO2Pico·tempo de esforço; AerRD) não foi diferente da Aer (10.36 ± 1.56 L vs. 10.31 ± 1.48 L), além de apresentar baixo erro médio (-0.15 L). Dessa forma, como o AODRED é determinado pelas concentrações pico de lactato e cinética off do consumo de oxigênio, seria possível avaliar o... / Due to the need to optmize the methods of anaerobic capacity determination, the aim of the present doctor thesis was validate the evaluation of accumulated oxygen deficit (AOD) by the backward extrapolation technique (AODRED). For this, 25 swimmers were evaluated and four scientific works were developed. The first study aimed to compare VO2Peak and sVO2Peak of swimmers obtained after a maximal 400 m effort and free-swimming incremental test. Eleven swimmers performed a maximal 400m effort and an incremental protocol to determine both variables. Besides no difference between VO2Peak (3.86 ± 0.85 L∙min-1 vs. 4.09 ± 0.93 L∙min-1), the sVO2Peak 1.39 ± 0.12 m∙s-1 vs. 1.34 ± 0.13 m∙s-1) was higher in the incremental test. The second study aumed compare AODRED (i.e. sum of lactic and alactic metabolism) with the AOD after a maximal 400m effort. The AOD was considered as the difference between theoretical demand (TD) and aerobic contribution (Aer), while AODRED was evaluated by the sum of anaerobic metabolisms. No difference between AOD (3.29 ± 1.34 LO2) and AODRED (3.24 ± 1.56 L O2), significant correlation (r = 0.95), and low mean standard estimative error (0.04 L) were found between the methodologies. Since no difference was found, the third study aimed to verify the possibility to estimate Aer only by the use of AODRED. Six swimmers were submitted to a maximal 400m effort with snorkel. The Aer estimated by the rectangular demand (i.e. VO2Peak·effort time; AerRD) was not different from Aer (10.36 ± 1.56 L vs. 10.31 ± 1.48 L), and presented low mean error (-0.15 L). Thus, since AODRED is determined by peak lactate concentration and off transient oxygen kinetics, it would be possible the AODRED by the backward extrapolation technique. Thus, the forth study aimed to test the reliability and validity of free-swimming AODRED (i.e. backward extrapolation). For this, eight swimmers performed two 400m efforts without snorkel ... / FAPESP: 13/15322-31
2

Determinação do máximo déficit acumulado de oxigênio de nadadores por meio da técnica de retro extrapolação /

Campos, Eduardo Zapaterra. January 2015 (has links)
Orientador: Marcelo Papoti / Banca: Paulo Roberto Pereira Santiago / Banca: Julio Wilson dos Santos / Banca: Gustavo Gomes de Araújo / Banca: Adelino Sanchez Ramos da Silva / Resumo: Devido à necessidade de otimização dos métodos de determinação da capacidade anaeróbia, o objetivo da presente tese de doutorado foi validar a avaliação do déficit acumulado de oxigênio (AOD) por meio da técnica de retro extrapolação (AODRED). Para isso, 25 nadadores foram avaliados e quatro trabalhos foram desenvolvidos. O primeiro trabalho objetivou comparar o VO2Pico e a vVO2Pico de nadadores obtidos após esforço máximo de 400 m e teste incremental em nado livre. Onze nadadores realizaram esforço máximo de 400m e protocolo incremental para determinar ambas variáveis. Apesar de nenhuma diferença entre VO2Pico (3.86 ± 0.85 L∙min-1 vs. 4.09 ± 0.93 L∙min-1), a vVO2Pico (1.39 ± 0.12 m∙s-1 vs. 1.34 ± 0.13 m∙s-1) foi superior durante teste incremental. O segundo trabalho objetivou comparar o AODRED (i.e. soma dos metabolismos lático e alático) com o AOD após esforço máximo de 400m. Para isso seis atletas foram submetidos à quatro exercícios submáximos e um esforço máximo de 400m. O AOD foi considerado a diferença entre a demanda teórica (DT) e a contribuição aeróbia (Aer), enquanto o AODRED foi avaliado pela soma dos metabolismos anaeróbios. Nenhuma diferença entre AOD (3.29 ± 1.34 LO2) e AODRED (3.24 ± 1.56 L O2), correlações significantes (r = 0.95) e baixo erro médio de estimativa (0.04 L) foram encontrados entre as metodologias. Haja vista que nenhuma diferença foi encontrada, o terceiro estudo objetivou verificar a possibilidade de se estimar a Aer apenas pelo uso do AODRED. Seis nadadores foram submetidos à um esforço máximo de 400m com snórquel. A Aer estimada pela demanda retangular (i.e. VO2Pico·tempo de esforço; AerRD) não foi diferente da Aer (10.36 ± 1.56 L vs. 10.31 ± 1.48 L), além de apresentar baixo erro médio (-0.15 L). Dessa forma, como o AODRED é determinado pelas concentrações pico de lactato e cinética off do consumo de oxigênio, seria possível avaliar o... / Abstract: Due to the need to optmize the methods of anaerobic capacity determination, the aim of the present doctor thesis was validate the evaluation of accumulated oxygen deficit (AOD) by the backward extrapolation technique (AODRED). For this, 25 swimmers were evaluated and four scientific works were developed. The first study aimed to compare VO2Peak and sVO2Peak of swimmers obtained after a maximal 400 m effort and free-swimming incremental test. Eleven swimmers performed a maximal 400m effort and an incremental protocol to determine both variables. Besides no difference between VO2Peak (3.86 ± 0.85 L∙min-1 vs. 4.09 ± 0.93 L∙min-1), the sVO2Peak 1.39 ± 0.12 m∙s-1 vs. 1.34 ± 0.13 m∙s-1) was higher in the incremental test. The second study aumed compare AODRED (i.e. sum of lactic and alactic metabolism) with the AOD after a maximal 400m effort. The AOD was considered as the difference between theoretical demand (TD) and aerobic contribution (Aer), while AODRED was evaluated by the sum of anaerobic metabolisms. No difference between AOD (3.29 ± 1.34 LO2) and AODRED (3.24 ± 1.56 L O2), significant correlation (r = 0.95), and low mean standard estimative error (0.04 L) were found between the methodologies. Since no difference was found, the third study aimed to verify the possibility to estimate Aer only by the use of AODRED. Six swimmers were submitted to a maximal 400m effort with snorkel. The Aer estimated by the rectangular demand (i.e. VO2Peak·effort time; AerRD) was not different from Aer (10.36 ± 1.56 L vs. 10.31 ± 1.48 L), and presented low mean error (-0.15 L). Thus, since AODRED is determined by peak lactate concentration and off transient oxygen kinetics, it would be possible the AODRED by the backward extrapolation technique. Thus, the forth study aimed to test the reliability and validity of free-swimming AODRED (i.e. backward extrapolation). For this, eight swimmers performed two 400m efforts without snorkel ... / Doutor
3

Demanda energética na sessão de exercício resistido com características de hipertrofia e resistência muscular localizada

Campanholi Neto, Jose [UNESP] 31 March 2015 (has links) (PDF)
Made available in DSpace on 2016-01-13T13:27:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-31. Added 1 bitstream(s) on 2016-01-13T13:32:27Z : No. of bitstreams: 1 000855858.pdf: 2461182 bytes, checksum: b1087380ea6cba7a72e730c212896aba (MD5) / Uma das estratégias utilizadas para proporcionar ao organismo maior demanda energética (DE) é a prática de exercício resistido (ER). Ao manipular corretamente as variáveis volume e a intensidade é possível otimizar a DE durante as sessões de ER. A DE no ER é constituída de dois componentes: o aeróbio, vinculado ao consumo de oxigênio, e anaeróbio, relacionado ao acúmulo de lactato. Com o objetivo de: a) comparar os efeitos agudos da sessão de ER (hipertrofia x RML) sobre DE total durante duas sessões de volume equiparado; b) investigar e comparar a participação dos componentes aeróbio e anaeróbio durante duas sessões de ER, com o mesmo volume; c) verificar em qual das intensidades estudadas ocorre maior concentração de lactato após as sessões; d) analisar a distribuição do tempo (exercícios e recuperação) nas sessões de ER; e) examinar qual das sessões de ER estudadas provocam maior percepção subjetiva de esforço. Para este fim no presente estudo foram avaliados 13 voluntários, homens, saudáveis, com idade de ( ̅ ± EP) 27,08 ± 1,48 anos; estatura de 176,8 ± 1,83 cm; massa corporal 85,38 ± 2,95 kg; percentual de massa gorda (%G) 18,38 ± 1,51 % duas sessões de ER de volume equiparado com intensidade característica de hipertrofia (70% 1RM) e RML (50% 1RM) em oito exercícios com intervalo de recuperação de 120 segundos. Para determinação do componente aeróbio e anaeróbio foi avaliado o consumo de oxigênio durante as sessões e variação da lactacidemia (Δ lactato x Kg de massa corporal x 3,3 ml O2). Os valores da demanda energética total ( ̅ ± EP) das sessões de hipertrofia (70%) e RML (50%) foram 372,0 ± 22,1 kcal e 305,4 ± 13,6 kcal, respectivamente, p = 0,0002. O metabolismo energético aeróbio da sessão foi responsável por 96,2% e 94,3% da demanda energética nas sessões de hipertrofia e RML, respectivamente. Na análise estatística do momento pós-sessão, houve uma diferença... / One of the strategies used to increase energy expenditure (EE) is the practice of resistance training (RT). Correctly handling the variables volume and intensity allows to optimize EE during RT sessions. The EE in RT is composed of two components: the aerobic, linked to oxygen consumption, and anaerobic, related to lactate accumulation. The purposes of this study were: a) to compare the acute effects of RT (hypertrophy vs. endurance) over total EE during two sessions of equal work; b) investigate and compare the participation of aerobic and anaerobic components during two RT sessions of equal work; c) check in which of the studied intensities lead to the highest concentration of lactate after the sessions; d) analyze the distribution of time (exercises and recovery) in RT sessions; e) examine which of the RT sessions studied causes the highest ratings of perceived exertion. Thirteen healthy adult men (( ̅ ± SE) age 27.08 ± 1.48 years; height 176.8 ± 1.83 cm; body mass 85.38 ± 2.95 kg; body fat 18.38 ± 1.51 %) participated in the study. Subjects performed eight resistance training exercises. To equate workload, the hypertrophy session involved performing 3 sets of 10 reps at 70% 1RM, while the endurance session involved performing 2 sets of 21 reps at 50% 1RM, followed by a 120 second rest period. EE was calculated as the sum of oxygen uptake (aerobic component) and lactate production (anaerobic component) that was calculated as the difference between resting and peak lactate values multiplied by body weight (kg), then by an equivalent of 3.3 ml of O2. During RT sessions there was significant difference in EE between the hypertrophy (70% 1RM) 372.0 ± 22.1 kcal and endurance (50% 1RM) 305.4 ± 13.6 kcal, p = 0.0002. The aerobic energy metabolism of the session accounted for 96.2% and 94.3% of energy demand in hypertrophy and endurance sessions, respectively. Statistical analysis after session, revealed a significant difference in ...
4

Demanda energética na sessão de exercício resistido com características de hipertrofia e resistência muscular localizada /

Campanholi Neto, Jose. January 2015 (has links)
Orientador: Vilmar Baldissera / Banca: Autran José da Silva Júnior / Banca: Taisa Belli / Resumo: Uma das estratégias utilizadas para proporcionar ao organismo maior demanda energética (DE) é a prática de exercício resistido (ER). Ao manipular corretamente as variáveis volume e a intensidade é possível otimizar a DE durante as sessões de ER. A DE no ER é constituída de dois componentes: o aeróbio, vinculado ao consumo de oxigênio, e anaeróbio, relacionado ao acúmulo de lactato. Com o objetivo de: a) comparar os efeitos agudos da sessão de ER (hipertrofia x RML) sobre DE total durante duas sessões de volume equiparado; b) investigar e comparar a participação dos componentes aeróbio e anaeróbio durante duas sessões de ER, com o mesmo volume; c) verificar em qual das intensidades estudadas ocorre maior concentração de lactato após as sessões; d) analisar a distribuição do tempo (exercícios e recuperação) nas sessões de ER; e) examinar qual das sessões de ER estudadas provocam maior percepção subjetiva de esforço. Para este fim no presente estudo foram avaliados 13 voluntários, homens, saudáveis, com idade de ( ̅ ± EP) 27,08 ± 1,48 anos; estatura de 176,8 ± 1,83 cm; massa corporal 85,38 ± 2,95 kg; percentual de massa gorda (%G) 18,38 ± 1,51 % duas sessões de ER de volume equiparado com intensidade característica de hipertrofia (70% 1RM) e RML (50% 1RM) em oito exercícios com intervalo de recuperação de 120 segundos. Para determinação do componente aeróbio e anaeróbio foi avaliado o consumo de oxigênio durante as sessões e variação da lactacidemia (Δ lactato x Kg de massa corporal x 3,3 ml O2). Os valores da demanda energética total ( ̅ ± EP) das sessões de hipertrofia (70%) e RML (50%) foram 372,0 ± 22,1 kcal e 305,4 ± 13,6 kcal, respectivamente, p = 0,0002. O metabolismo energético aeróbio da sessão foi responsável por 96,2% e 94,3% da demanda energética nas sessões de hipertrofia e RML, respectivamente. Na análise estatística do momento pós-sessão, houve uma diferença... / Abstract: One of the strategies used to increase energy expenditure (EE) is the practice of resistance training (RT). Correctly handling the variables volume and intensity allows to optimize EE during RT sessions. The EE in RT is composed of two components: the aerobic, linked to oxygen consumption, and anaerobic, related to lactate accumulation. The purposes of this study were: a) to compare the acute effects of RT (hypertrophy vs. endurance) over total EE during two sessions of equal work; b) investigate and compare the participation of aerobic and anaerobic components during two RT sessions of equal work; c) check in which of the studied intensities lead to the highest concentration of lactate after the sessions; d) analyze the distribution of time (exercises and recovery) in RT sessions; e) examine which of the RT sessions studied causes the highest ratings of perceived exertion. Thirteen healthy adult men (( ̅ ± SE) age 27.08 ± 1.48 years; height 176.8 ± 1.83 cm; body mass 85.38 ± 2.95 kg; body fat 18.38 ± 1.51 %) participated in the study. Subjects performed eight resistance training exercises. To equate workload, the hypertrophy session involved performing 3 sets of 10 reps at 70% 1RM, while the endurance session involved performing 2 sets of 21 reps at 50% 1RM, followed by a 120 second rest period. EE was calculated as the sum of oxygen uptake (aerobic component) and lactate production (anaerobic component) that was calculated as the difference between resting and peak lactate values multiplied by body weight (kg), then by an equivalent of 3.3 ml of O2. During RT sessions there was significant difference in EE between the hypertrophy (70% 1RM) 372.0 ± 22.1 kcal and endurance (50% 1RM) 305.4 ± 13.6 kcal, p = 0.0002. The aerobic energy metabolism of the session accounted for 96.2% and 94.3% of energy demand in hypertrophy and endurance sessions, respectively. Statistical analysis after session, revealed a significant difference in ... / Mestre
5

Sistema de medição para oximetria de pulso

Andrade, Luiz Augusto Kalva de 30 October 2009 (has links)
Este estudo tem como objetivo o desenvolvimento de um sistema para oximetria de pulso destinado a medir a saturação arterial de oxigênio. A determinação da saturação de oxigênio no sangue é reconhecida mundialmente como padrão de cuidado em anestesiologia, sendo utilizado em diversas aplicações desde tratamentos intensivos em hospitais até cirurgias veterinárias. O sistema de oximetria desenvolvido emprega um sensor de transmitância utilizando LEDs e um fotodetector como componentes principais. O instrumento é composto de um amplificador de transimpedância, circuito de demultiplexação, filtros passa-faixas, amplificador de ganho digitalmente programável e um processador digital de sinais. Os resultados de funcionamento do protótipo foram comparados com um simulador de oximetria de pulso comercial, obtendo-se um coeficiente r = 0,99954 entre os dados de saturação de oxigênio. Medições in vivo obtidas foram comparadas com medições feitas por um oxímetro comercial, atingindo-se diferenças médias de ±1,67% entre os dados de percentagem de saturação pulsátil e ±1,44 batimentos cardíacos para a taxa de batimentos por minuto. Espera-se que este trabalho possa contribuir para melhorar a monitorização de oxigênio aos tecidos do corpo tornando ainda mais comum e acessível o uso da técnica de medição da oximetria de pulso. / The main subject of this research is the development of a measurement system for pulse oximetry in order to determine oxygen arterial saturation. The measurement of blood oxygen saturation is recognized as a world standard in anesthesiology care, being used in intensive care units as well as in veterinary surgery. The developed oximetry system employs a transmittance probe using light emitting diodes and a photo detector as main components. The instrument is also composed by a transimpedance amplifier, demux and sample-and-hold circuits, pass-band filters, digitally controlled amplifier and a digital signal processor. The functioning results of the prototype were confirmed by using a commercial pulse oximeter simulator, obtaining a coefficient r = 0.99954 between the oxygen saturation data. Also, in vivo results obtained were compared with a commercial pulse oximeter showing mean differences of ±1.67% for percentage saturation data and ±1.44 beats per minute for heart rate. It is hoped that this work can help to improve the oxygen monitoring to body tissues and to make pulse oximetry a more common and accessible monitoring technique.
6

Sistema de medição para oximetria de pulso

Andrade, Luiz Augusto Kalva de 30 October 2009 (has links)
Este estudo tem como objetivo o desenvolvimento de um sistema para oximetria de pulso destinado a medir a saturação arterial de oxigênio. A determinação da saturação de oxigênio no sangue é reconhecida mundialmente como padrão de cuidado em anestesiologia, sendo utilizado em diversas aplicações desde tratamentos intensivos em hospitais até cirurgias veterinárias. O sistema de oximetria desenvolvido emprega um sensor de transmitância utilizando LEDs e um fotodetector como componentes principais. O instrumento é composto de um amplificador de transimpedância, circuito de demultiplexação, filtros passa-faixas, amplificador de ganho digitalmente programável e um processador digital de sinais. Os resultados de funcionamento do protótipo foram comparados com um simulador de oximetria de pulso comercial, obtendo-se um coeficiente r = 0,99954 entre os dados de saturação de oxigênio. Medições in vivo obtidas foram comparadas com medições feitas por um oxímetro comercial, atingindo-se diferenças médias de ±1,67% entre os dados de percentagem de saturação pulsátil e ±1,44 batimentos cardíacos para a taxa de batimentos por minuto. Espera-se que este trabalho possa contribuir para melhorar a monitorização de oxigênio aos tecidos do corpo tornando ainda mais comum e acessível o uso da técnica de medição da oximetria de pulso. / The main subject of this research is the development of a measurement system for pulse oximetry in order to determine oxygen arterial saturation. The measurement of blood oxygen saturation is recognized as a world standard in anesthesiology care, being used in intensive care units as well as in veterinary surgery. The developed oximetry system employs a transmittance probe using light emitting diodes and a photo detector as main components. The instrument is also composed by a transimpedance amplifier, demux and sample-and-hold circuits, pass-band filters, digitally controlled amplifier and a digital signal processor. The functioning results of the prototype were confirmed by using a commercial pulse oximeter simulator, obtaining a coefficient r = 0.99954 between the oxygen saturation data. Also, in vivo results obtained were compared with a commercial pulse oximeter showing mean differences of ±1.67% for percentage saturation data and ±1.44 beats per minute for heart rate. It is hoped that this work can help to improve the oxygen monitoring to body tissues and to make pulse oximetry a more common and accessible monitoring technique.

Page generated in 0.0899 seconds