• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Qualidade de vida de pacientes com defeito do pavilhão auricular, reabilitados e em processo de reabilitação : avaliação da resistência à tração e torque dos parafusos dos implantes dos sistemas de retenção para próteses auriculares implantorretidas em função de ciclagem mecânica / Life quality of patients with auricular defects, rehabilitated and in phase of rehabilitation with implant-retained auricular prostheses and evaluation of tensile strength and torque of the screws of the attachment systems to retained-implant auricular prosthesis, in function of mechanical cycles

Santos, Mateus Veppo dos 09 July 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2015-11-20T19:12:11Z No. of bitstreams: 1 2015_MateusVeppodosSantos.pdf: 1223994 bytes, checksum: 9e81488339c90d29af20465bbda9fb4c (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-05-12T20:32:38Z (GMT) No. of bitstreams: 1 2015_MateusVeppodosSantos.pdf: 1223994 bytes, checksum: 9e81488339c90d29af20465bbda9fb4c (MD5) / Made available in DSpace on 2016-05-12T20:32:38Z (GMT). No. of bitstreams: 1 2015_MateusVeppodosSantos.pdf: 1223994 bytes, checksum: 9e81488339c90d29af20465bbda9fb4c (MD5) / No presente estudo, foi realizada a análise da qualidade de vida de pacientes com defeito do pavilhão auricular, reabilitados e em processo de reabilitação por próteses auriculares implantorretidas, e a avaliação mecânica dos sistemas de retenção para próteses auriculares implantorretidas, em função de ciclagem mecânica. Para o primeiro estudo, 18 pacientes, de ambos os sexos e maiores de 12 anos de idade, responderam aos questionários WHOQOL-bref e de auto-avaliação, que visa avaliar diversas facetas relacionadas à qualidade de vida. Os dados obtidos foram tabulados e submetidos à análise estatística descritiva. Para o segundo estudo, foram confeccionados corpos de prova para avaliar a resistência à tração dos sistemas de retenção barra-clipe, O’ring, associação dos mesmos, e magnetos. As amostras foram submetidas a 1080 ciclos mecânicos de inserção e remoção, com registro da força de resistência à tração e torque dos parafusos, em 0 e 1080 ciclos. Os resultados obtidos, a partir dos questionários, demonstraram que a percepção da qualidade de vida pelos pacientes, em todos os aspectos analisados, foi considerada boa, independente da reabilitação ter sido concluída. Como resultado da retenção e torque, observamos que a associação dos sistemas barra-clipe e o’ring proporcionou maior retenção do que os demais; que houve diminuição da força de resistência à tração e torque dos parafusos após a ciclagem, independente do sistema. Concluímos que, apesar dos seus defeitos faciais, os pacientes mantém boa qualidade de vida e que os reabilitados por próteses devem fazer consultas de retorno, tanto para troca das próteses como para controle do torque dos parafusos e dos sistemas de retenção, devido ao uso diário da prótese. _______________________________________________________________________________________________ ABSTRACT / In the present study, was analyzed the quality of life in patients with auricular defects, rehabilitated and in phase of rehabilitation with implant-retained auricular prostheses, and also the retention strength and torque of the screws of the implants attachment systems for implant-retained auricular prostheses were evaluated mechanical cycling function. For the first study a total of eighteen patients of both genders and over the age of twelve answered the WHOQOL-Bref and self-evaluation, questionnaires used to assess different aspects related to quality of life. Data were tabulated and subjected to descriptive statistical analysis. In the second study, templates were done to evaluate Bar-clip, O’ring, bar-clip and o’ring associated, and magnets systems. The templates were submitted to 1080 mechanical cycles and were evaluated the force of traction and screw torque for each system in two stages: initial and after 1080 mechanical cycles. The results from the questionnaires showed that the patients quality of life perception, in all aspects evaluated, were considered good. The results about traction and screw torque showed that bar-clip and o’ring associated systems provides greater retention than the others attachment systems; there was a decreased resistance force to traction and torque of the screws after cycling, regardless of the system. We conclude that despite its auricular defects, patients maintain a good quality of life and those rehabilitated should make regular follow-ups, because of the a loss of torque of the screws of the implants and loss of retentive capacity of the attachment systems caused by the daily use of the prosthesis.
2

Estudo e desenvolvimento de tecnologias e técnicas para obtenção de prótese auricular com custo-efetividade por meio de modelagem 3d e manufatura aditiva

Artioli, Bárbara Olivetti January 2017 (has links)
Orientadora: Profª. Drª. Maria Elizete Kunkel / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Engenharia Biomédica, 2017. / A reconstrução auricular está presente desde 600 a.C. na forma de implante de retalhos de pele. Nos últimos anos, tem ocorrido cada vez mais pesquisas sobre o desenvolvimento de próteses que visam substituir um órgão do paciente sem a necessidade de realização de cirurgias. Novas tecnologias, como processos de aquisição da anatomia e manufatura aditiva, têm sido investigadas como alternativa para a produção de próteses auriculares com uma melhor relação custo/qualidade quando comparada com o processo manual. Nesta pesquisa foi desenvolvida uma metodologia para investigar o uso de quatro métodos de aquisição da estrutura externa do pavilhão auricular de uma voluntária (fotogrametria, escaneamento 3D, reconstrução 3D de imagens de tomografia computadorizada e modelagem 3D parametrizada) para a produção de moldes de prótese auricular por manufatura aditiva (técnica de deposição de material fundido). As próteses auriculares de silicone produzidas com esta metodologia apresentaram um excelente resultado estético com menos 3% de erro dimensional. Além disso, análises mecânicas (ensaios de resistência à tração e dureza) do silicone utilizado revelaram que as próteses produzidas apresentam ótima resistência mecânica que não é alterada pelo processo de pigmentação. Ensaios com pele suína mostraram que, dos quatro adesivos analisados, três apresentaram força de adesão satisfatória. Os resultados demonstram a viabilidade de uma metodologia acessível para a produção de próteses de orelhas utilizando softwares livres, tecnologias e suprimentos disponíveis no mercado brasileiro. / The auricular reconstruction is present since 600 BC through skin flaps implants. In the current years, prostheses have been developed to replace the patient's organ without the use of surgeries. Recently, new technologies, such as anatomical acquisition and additive manufacturing techniques are being applied in the production of auricular prostheses, aiming at obtaining a product with better cost/quality relation when compared to the manual manufacturing process. In this research, a methodology was developed to investigate the use of four methods to acquire the external structure of a volunteer's ear (photogrammetry, 3D scanning, 3D reconstruction of computed tomography images and parameterized 3D modeling) for the production of auricular prosthesis molds by additive manufacture (melt deposition technique). The silicone ear prosthesis produced with the presented methodology shows an excellent esthetic result with only 3% dimensional error. In addition, mechanical analysis (tensile strength and hardness tests) of the used silicone showed that the produced prostheses has excellent mechanical resistance that is not altered by the pigmentation process. Tests with swine skin showed that, of the four analyzed adhesives , three had satisfactory adhesion strength. The results demonstrate the feasibility of an accessible methodology for the production of ear prostheses using free softwares, technologies and supplies available in the Brazilian market.

Page generated in 0.021 seconds