• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 23
  • 6
  • 6
  • 4
  • 2
  • 2
  • Tagged with
  • 130
  • 40
  • 30
  • 28
  • 26
  • 24
  • 23
  • 22
  • 20
  • 20
  • 20
  • 19
  • 19
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Desenvolvimento do fantasma matematico de uma crianca de 10 anos de idade para fins de dosimetria interna

DEUS, SUDERNAIQUE F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:41Z (GMT). No. of bitstreams: 1 01056.pdf: 9216178 bytes, checksum: 1bd6e90e03bfc38d02eb59996c618992 (MD5) / Tese (Doutoramento) / IEA/T / Instituto de Energia Atomica - IEA
22

Desenvolvimento de material simulador de tecido humano a partir do latex de borracha natural vulcanizado com radiacao gama

TOMIMASU, SUMIE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:02Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:01Z (GMT). No. of bitstreams: 1 07006.pdf: 15307556 bytes, checksum: c9788962df8605b765ce5760357ba775 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
23

Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generation

CARVALHO, DIEGO V. de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:06:37Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:06:37Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
24

Avaliacao de dosimetros termoluminescentes empregando objetos simuladores equivalentes a agua para aplicacao na dosimetria de feixes clinicos de eletrons / Evaluation of thermoluminescent dosimeters using water equivalent phantoms for application in clinical electrons beams dosimetry

BRAVIM, AMANDA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:50Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:12Z (GMT). No. of bitstreams: 0 / A dosimetria em Radioterapia prevê a calibração do feixe de radiação e a dosimetria de rotina para controle de qualidade, pois o seu principal objetivo é determinar, com maior precisão, a dose absorvida pelo tumor. Este trabalho tem como objetivo avaliar o comportamento de três dosímetros termoluminescentes na dosimetria de feixes clínicos de elétrons. O desempenho de detectores de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN foi comparado com o de dois dosímetros comercialmente disponíveis pela Harshaw, ambos denominados TLD-100, porém com dimensões distintas. Os dosímetros foram caracterizados com a utilização de objetos simuladores de água, água sólida RMI-457 e PMMA em campos de radiação de elétrons de 4, 6, 9, 12 e 16 MeV. Também foram realizadas medidas em feixes de fótons de 6 e 15 MV (2 e 5 MeV) apenas para comparação de resultados. As curvas de dose-resposta foram obtidas para a radiação gama do 60Co no ar e em condições de equilíbrio eletrônico e para feixes clínicos de fótons e elétrons nas profundidades de máxima dose. A sensibilidade, a reprodutibilidade, a eficiência intrínseca e a dependência energética dos dosímetros termoluminescentes foram estudadas. O CaSO4:Dy apresentou comportamento semelhante ao dos TLD-100 com uma vantagem em relação à sensibilidade para os feixes e doses de radiação estudados. Sendo assim, o dosímetro produzido pelo IPEN pode ser considerado uma nova alternativa para a dosimetria nos departamentos de Radioterapia. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
25

Desenvolvimento do manequim matematico do homem brasileiro para calculos de dosimetria interna

GUIMARAES, MARIA I.C.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:51Z (GMT). No. of bitstreams: 1 06045.pdf: 15655492 bytes, checksum: 6cfb83e47451ce75631c870bbce0e7cd (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
26

Desenvolvimento do fantasma matematico de uma crianca de 10 anos de idade para fins de dosimetria interna

DEUS, SUDERNAIQUE F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:41Z (GMT). No. of bitstreams: 1 01056.pdf: 9216178 bytes, checksum: 1bd6e90e03bfc38d02eb59996c618992 (MD5) / Tese (Doutoramento) / IEA/T / Instituto de Energia Atomica - IEA
27

Desenvolvimento de material simulador de tecido humano a partir do latex de borracha natural vulcanizado com radiacao gama

TOMIMASU, SUMIE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:02Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:01Z (GMT). No. of bitstreams: 1 07006.pdf: 15307556 bytes, checksum: c9788962df8605b765ce5760357ba775 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
28

Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generation

CARVALHO, DIEGO V. de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:06:37Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:06:37Z (GMT). No. of bitstreams: 0 / O estudo do efeito da colimação nos detectores de radiação sobre a qualidade de imagem do tomógrafo industrial de terceira geração desenvolvido no IPEN/CNEN-SP é descrito neste trabalho. Três conjuntos de colimadores de chumbo foram projetados e confeccionados, sendo um com janelas retangulares de 2 x 5 x 50 mm e outro com 4 x 10 x 50 mm (largura x comprimento x profundidade) e um terceiro com orifício circular de 5 mm de diâmetro x 40 mm de profundidade. Os colimadores foram projetados para poderem ser facilmente substituídos entre si nos detectores de radiação. Paralelamente, foram confeccionados e utilizadas a eletrônica associada, constituída de analisadores de sinais tipo multicanal de 8 bits contendo a unidade de alta tensão e o amplificador. Dentre as vantagens deste sistema destaca-se a sua capacidade de análise multicanal rápida e possuir uma eletrônica mais simples. Valores de resolução energética comparável com a da literatura foram encontrados utilizando a eletrônica desenvolvida acoplada ao detector de radiação de NaI(Tl). Os efeitos dos colimadores foram avaliados pelas medidas tomográficas em um fantom de polimetilmetacrilato contendo componentes multifásicos estáticos (ferro, alumínio e ar). Fontes de radiação com energias de das fontes de 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV e 400 keV), de 137Cs (662 keV) e de 192Ir (317 keV, 468 keV e 602 keV) observou-se que a melhor imagem do fantom foi obtida com os colimadores de janelas retangulares (fendas) de 2 x 5 x 50 mm. Na avaliação dinâmica da formação de bolhas em coluna simuladora de processos industriais, a melhor imagem foi obtida com a fonte de 192Ir. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
29

Reconstrução Tomográfica com superfícies B-splines

Ferreira de Oliveira, Eric 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T23:14:42Z (GMT). No. of bitstreams: 2 arquivo2690_1.pdf: 6789118 bytes, checksum: 05cc3d356f57a760866a4fc16453b6e0 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Vários estudos têm indicado que, das várias classes de algoritmos de reconstrução aplicáveis para dados limitados, os baseados na técnica de reconstrução algébrica são mais flexíveis e precisos. Infelizmente, estas técnicas, geralmente, sofrem de ruídos ocasionados por processos de correção durante a reconstrução e também por inconsistências nos dados adquiridos pelos tomógrafos. O pós - processamento da imagem reconstruída com a aplicação de filtros pode ser feito para atenuar a presença de ruídos, mas geralmente atenuam também as descontinuidades presentes em bordas que distinguem objetos ou falhas. O presente trabalho propõe a redução de ruídos assegurando a continuidade (das derivadas) da superfície antes da reconstrução, representando cada incógnita por uma combinação linear de pontos de controle e suas bases B-splines. São aplicadas três bases Bsplines: B1 , B2 e B3, assegurando as continuidade C0, C1 e C2, respectivamente. Para validação da técnica, foram utilizadas simulações de modelos propostos na literatura e medidas experimentais por tomografia gama. Os resultados foram comparados com as técnicas algébricas ART, SIRT, MART e SMART, sendo validada satisfatoriamente para todos os phantoms propostos. Todas as bases B-splines aplicadas obtiveram erros menores que as técnicas de correção ART e SIRT, sendo a B3, a de melhor desempenho. Este resultado pode ser explicado pelas restrições de suavidade impostas à superfície reconstruída pelas bases Bsplines e a inclinação das técnicas aditivas a ruídos, principalmente para um número limitado de dados (5 e 10 vistas). A performance das técnicas multiplicativas para essa situação é a melhor, mostrando uma imagem sem artefatos e com pouco ruído. Devido a esse fato, a técnica b-spline não tem bons resultados, apresentando na maioria dos casos, erros maiores. Para todos os testes realizados, as técnicas de representação B-splines superaram os filtros de mesma natureza aplicados no pós-processamento, sugerindo que a técnica seja utilizada no lugar da filtragem pós-processamento
30

SENSITIVITY OF DIFFUSE CORRELATION SPECTROSCOPY TO FLOW RATES IN TISSUE-SIMULATING OPTICAL PHANTOMS

Zanfardino, Sara Marie 01 August 2018 (has links)
No description available.

Page generated in 0.0243 seconds