61 |
Análise de tensões em pilares de próteses implantossuportadas em função da sequência de aparafusamento e do torque progressivoBarcellos, Leonardo Hoffmann de January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:14Z (GMT). No. of bitstreams: 2
000425140-0.pdf: 832261 bytes, checksum: 4413ad773642b662c2ac5d0e51f68ef9 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the influence of four screw tightening sequences and the mode of torque application on the residual tension in a simulation of full-arch mandibular prosthesis supported by five implants. Four metallic frameworks were fabricated, and strain gauges were attached to the implant abutments in order to measure the generated tensions on the implant-framework system during the experiments. The screw-retained frameworks were fixed with a 10 N. cm torque using four different screw tightening sequences: I) 2-4-3-1-5; II) 1-2-3-4-5; III) 3-2-4-1-5; and IV) 2-5-4-1-3. The same sequences were repeated in each framework using a progressive torque method, firstly with a 5 N. cm torque in each screw, followed by a 10 N. cm torque. Data were analyzed by ANOVA for repeated measures and effect size test. No statistically significant differences in tension were found among the different screw tightening sequences. For the different methods for applying prosthetic screw torque, only one sequence (3-2-4-1-5) showed statistically significant difference in tension. The use of other screw tightening sequences did not yield significant differences in tension for either the directly applied torque or the progressive torque. / O presente estudo avaliou a influência da sequência de aparafusamento e do modo de aplicação de torque protético sobre a tensão residual em uma simulação de prótese implantossuportada tipo protocolo Branemark com cinco implantes. Quatro estruturas metálicas em forma de barra foram confeccionadas sobre um modelo simulando uma mandíbula com cinco implantes. Extensômetros de resistência elétrica foram colados aos pilares protéticos para medir a tensão durante o experimento de aparafusamento. As barras (n=4) foram aparafusadas com torque de 10 N. cm sobre os parafusos protéticos, utilizando-se quatro diferentes sequências de aparafusamento: I) 2-4-3-1-5; II) 1-2-3-4-5; III) 3-2-4-1-5 e IV) 2-5-4-1-3. O experimento foi repetido utilizando-se o aparafusamento de maneira progressiva, com a aplicação de um torque de 5 N. cm e posteriormente de 10 N. cm. Os resultados foram analisados por ANOVA de medidas repetidas e teste de tamanho de efeito padronizado. Não houve diferença estatisticamente significativa de tensão entre as sequências de aparafusamento. Houve diferença significativa de tensão entre a aplicação direta do torque protético (10 N. cm) e a utilização de um torque progressivo (5 N. cm + 10 N. cm) para a sequência de aparafusamento 3-2-4-1-5. As demais sequências de aparafusamento não apresentaram diferença estatisticamente significativa de tensão quando se comparou o modo de aplicação do torque protético.
|
62 |
Distribuição de força em pilares de próteses implantossuportadas tipo Protocolo Branemark com implantes inclinados: estudo in vitroGeremia, Tomás January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:26Z (GMT). No. of bitstreams: 2
000348626-0.pdf: 4950710 bytes, checksum: 4ebacb5fb961a07040b7f0a6d426dd6c (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study evaluated the distribution of force in abutments of Brånemark protocol prostheses, as a function of the inclination of the distal implants and the position of abutments in the arch. Specimens were ten metallic bar structures cast in Pd-Ag alloy, simulating Brånemark protocol prostheses supported by five implants. These structures were made over two master models: one model with five parallel and straight implants (n = 5) and one model with the distal implants tilted (n = 5). Strain gauges were fixed on the abutments of each master model to measure the deformation when a static load of 50 N was applied on the cantilever (15 mm) of each specimen. The deformation values were transformed into force values and analyzed by ANOVA for randomized blocks design, followed by Tukey's test multiple comparisons, at the 5% level of significance. The main factors (Model and Abutment) and their interaction were statistically significant. In the straight model, abutment #1 (adjacent to cantilever) had the highest mean force; abutment #2 had higher force than abutment #5. In the model with tilted distal implants, abutment #1 showed the highest force, and the other abutments (#2, 3, 4, and 5) were not different from each other. In the model with straight implants, the compressive force on abutment #1 exceeded in 2. 85 times the 50 N static load applied (142,52 N). In the model with tilted distal implants, the compressive force was 1. 70 times higher than the applied load (85,32 N). Comparing both models, only the mean force in abutment #1 of the straight model was higher than the same abutment in the tilted model. The results of this study suggest that the inclination of the posterior implants allow a better distribution of forces in abutments of Brånemark protocol prostheses. / Este estudo avaliou a distribuição da força em pilares protéticos de próteses tipo Protocolo Brånemark, em função da inclinação dos implantes distais e da posição dos pilares no arco. Os corpos-de-prova constituíram-se de dez barras metálicas em liga de Prata-Paládio, as quais simularam uma prótese fixa tipo Protocolo Brånemark sobre cinco implantes. Estas barras foram confeccionadas sobre dois modelos-mestre: um modelo com cinco implantes retos e paralelos entre si (n=5 barras) e outro com os dois distais inclinados (n=5 barras). Extensômetros foram colados nos pilares protéticos de cada modelo-mestre para medir a deformação quando da aplicação de uma carga estática de 50 N no extremo livre (15 mm) de cada barra metálica. Os valores de deformação dos pilares foram convertidos em força e analisados por ANOVA para delineamento em blocos casualizados, complementada pelo Teste de Comparações Múltiplas de Tukey, ao nível de significância de 5%. Os fatores principais (Modelo e Pilar) e a interação entre os fatores foram estatisticamente significativos. No modelo reto, o pilar 1 (adjacente ao cantilever) apresentou a maior média de força; o pilar 2 apresentou uma média maior do que o pilar 5. No modelo inclinado, o pilar 1 apresentou a maior média de força; os pilares 2, 3, 4 e 5 não diferiram entre si. No modelo com implantes retos, as forças compressivas no pilar 1 excederam em 2,85 vezes o valor da carga estática de 50 N (142,52 N). Já no modelo com implantes posteriores inclinados, as forças compressivas no pilar 1 excederam em 1,70 vezes o valor da carga aplicada (85,32 N). Na comparação entre os modelos, somente a média de força no pilar 1 no modelo reto foi significativamente maior do que no modelo inclinado. Os resultados deste estudo sugerem que a inclinação dos implantes posteriores permite uma melhor distribuição de forças em pilares para próteses tipo Protocolo Brånemark.
|
63 |
Distribuição de tensões em dois sistemas de implantes com pilares de fibra de vidro e titânio e osso adjacente através da análise por elementos finitosHerbstrith Segundo, Regênio Mahfuz January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:31Z (GMT). No. of bitstreams: 2
000425137-0.pdf: 1288305 bytes, checksum: 6a92199aeb43337370e8cff821e88682 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to compare and evaluate, through 3D finite element analysis, strain distribution generate by simulated loads over implants, abutments and metal ceramic crowns models and mandible surrounded bone. The analysis were executed in four 3D models: model 1 and 3 made by means of Ankylos® System external butt joint and models 2 and 4 made from Straumann System geometry, the standard loads was 382N(vertical) and 8N(horizontal), in 4 different observation points on the implant-abutment-screw set and 3 intra bone observation points in 2 different spots: cervical and apical. The results suggested that in a general way, the models 1 and 3 showed a better mechanic behavior related to strain distribution along the implant-abutment-screw set and in the bone models. The fiberglass abutments showed lower strain concentrations than titanium abutments in both studied systems. On both systems the cervical bone area showed higher volume of strain concentrations. / O objetivo deste estudo foi avaliar e comparar qualitativamente, através de análise por elementos finitos com modelo 3D, a distribuição das tensões geradas por cargas simuladas sob modelos de implantes, pilares, coroas protéticas metalocerâmicas e tecido ósseo mandibular. As análises foram executadas em 4 modelos tridimensionais: modelo 1 e modelo 3 construídos a partir do sistema Ankylos®, modelos 2 e 4 construídos a partir do sistema Straumann®, ambas conexões internas cone morse. As cargas aplicadas foram padronizadas em 382N(vertical) e 8N(horizontal), em 4 pontos diferentes de observação no conjunto implante-pilarparafuso e em 3 pontos de observação intraósseos em duas regiões diferentes, cervical e apical Os resultados obtidos sugeriram que, de uma maneira geral, os modelos 1 e 3 possuem um melhor comportamento mecânico em relação a distribuição de tensões ao longo do complexo implante-pilar-parafuso e em relação aos modelos ósseos. Os pilares feitos com fibra de vidro mostraram concentrações de tensão menores que seus homólogos em titânio em ambos sistemas estudados. Para ambos sistemas a região óssea de maior volume de tensões concentradas foi a cervical.
|
64 |
Distribuição das tensões em três tipos diferentes de próteses fixas implanto-suportadas tipo protocolo : estudo pelo método dos elementos finitosCoelho, Luiz Felipe Butzke January 2012 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2012-10-04T12:10:39Z
No. of bitstreams: 1
442212.pdf: 8469172 bytes, checksum: e497ae0c16d8dee2df60b87814113982 (MD5) / Made available in DSpace on 2012-10-04T12:10:39Z (GMT). No. of bitstreams: 1
442212.pdf: 8469172 bytes, checksum: e497ae0c16d8dee2df60b87814113982 (MD5) / O objetivo deste estudo foi avaliar e comparar de maneira qualitativa, por meio da análise por elementos finitos, a distribuição das tensões geradas por cargas simuladas em modelos 3D de implantes, pilares, próteses fixas tipo protocolo e tecido ósseo mandibular. As análises foram realizadas em três modelos tridimensionais: modelo A simulando um protocolo provisório de acrílico, modelo B simulando uma prótese tipo protocolo metaloplástico e modelo C, metalocerâmico. O carregamento oclusal foi padronizado em 100 N e aplicado no extremo distal do cantilever lado direito. Os resultados obtidos sugeriram que os modelos A, B e C apresentaram comportamentos biomecânicos diferentes quando exigidos pelo mesmo esforço mecânico. O modelo A (provisório de acrílico) foi o que apresentou o pior comportamento biomecânico nas estruturas analisadas. / The objective of this study was a qualitative evaluation and comparison by means of finite element analysis of the tension distribution generated by a simulated loading in 3D models of implants, abutments, fixed protocol prosthesis and mandibular bone tissues. The analysis were carried out in 3 tridimensional models: a) model A, simulating a temporary full-resin protocol prosthesis, b) model B, simulating a metal-resin protocol prosthesis, and c) model C, simulating a porcelain-fused-tometal protocol prosthesis. The results from our study suggested that models A, B, and C presented different biomechanical performances when submitted to the same mechanical load. Model A was the one which presented the worst biomechanical performance in the analyzed models.
|
65 |
Efetividade da desinfecção por energia de microondas de três resinas acrílicas contaminadas por leveduras do gênero Candida / Effectiveness of microwave disinfection of three acrylic resin contaminated by yeast of CadidaSilva, Manoela Capla de Vasconcellos dos Santos da, 1983- 17 August 2018 (has links)
Orientadores: Rafael Leonardo Xediek Consani, Janaína de Cássia Orlandi Sardi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T04:26:24Z (GMT). No. of bitstreams: 1
Silva_ManoelaCapladeVasconcellosdosSantosda_M.pdf: 1427757 bytes, checksum: 3e559b527f8ddc7215c4e2a25c440832 (MD5)
Previous issue date: 2010 / Resumo: Neste estudo o objetivo foi avaliar a efetividade da irradiação por energia de microondas na desinfecção de resinas acrílicas para confecção de próteses totais. Setenta e dois corpos-deprova em resina acrílica de diferentes tipos (Vipi convencional, Vipi Wave e Vipi convencional) foram confeccionados de forma padronizada e submetidos à esterilização com óxido de etileno. Na parte superior dos corpos-de-prova foram inoculados 100 µL do inóculo de uma das três espécies de Candida e posterior colocação em estufa a 37°C por 1 hora e 30 minutos para a realização da primeira aderência. Após este tempo, cada poço foi completado com meio estéril e a placa novamente levada à estufa para incubação a 37°C por 6 horas. Após essa incubação, os 54 corpos-de-prova foram imersos em 10 mL de água estéril e irradiados por energia de microondas a 650 W por 3 minutos. Dezoito corpos-deprova não irradiados foram considerados grupo controle. Após a incubação por 48 horas, tanto as placas das amostras irradiadas quanto as não irradiadas foram submetidas à contagem de colônias em contador de colônias digital. Os números de unidades formadoras de colônias por mililitro foram calculados e comparados estatísticamente para verificação da efetividade do método de desinfecção proposto. As semeaduras das placas de Petri referentes aos corpos-de-prova irradiados (grupo experimental) não apresentaram colônias viáveis para todos os microorganismos avaliados após incubação a 37ºC por 48 horas. Os resultados demonstraram efetiva esterilização após 3 minutos de irradiação a 650 W para todos os corpos-de-prova do grupo experimental. Os corpos-de-prova do grupo controle (não irradiadas) apresentaram crescimento microbiano após 48 horas de incubação. A irradiação por microondas a 650 W por 3 minutos mostrou ser um método efetivo na esterilização dos corpos-de-prova inoculados com C. albicans, C. dubliniensis e C. tropicalis / Abstract: The objective of this study was to evaluate the effectiveness of microwave irradiation in the disinfection of acrylic resins for the fabrication of dentures. Seventy two specimens of acrylic resin of different types were made in a standardized and subjected to sterilization with ethylene oxide. The specimens were individually inoculated with100 µL of inoculums of three species of Candida, and later placed in an incubator at 37°C for 1 hour and 30 minutes to perform the first adhesion. After this time, each well was supplemented with sterile media and the plate once again brought to a stove for incubation at 37°C for 6 hours. After this incubation, the 54 specimens were immersed in 10 mL of sterile water and irradiated by microwave energy at 650 W for 3 minutes. Eighteen specimens were
considered non-irradiated control group. After incubation for 48 hours, both plates of the irradiated samples as the non-irradiated were subjected to counting of colonies in colony digital counter. The number of colonies forming units per milliliter were calculated and compared to verify the effectiveness of the proposed method of disinfection. Cultivation of Petri plates relating to specimens irradiated (experimental group) showed no viable colonies for all microorganisms assessed after incubation at 37°C for 48 hours. The results demonstrated effective sterilization after 3 minutes of irradiation at 650W for all specimens the experimental group. Petri plates sown with the bodies corresponding specimens control group (not irradiated) showed microbial growth after 48 hours of incubation. A microwave irradiation at 650 W for three minutes proved to be an effective method of sterilization of the specimens inoculated with C. albicans, C. dubliniensis and C. tropicalis / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
66 |
Efeito do dispositivo RS de contensão, sobre a alteração dimensional das bases de protese total superiorConsani, Rafael Leonardo Xediek, 1974- 17 October 2000 (has links)
Orientador: Saide Sarckis Domitti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T09:40:54Z (GMT). No. of bitstreams: 1
Consani_RafaelLeonardoXediek_M.pdf: 5078942 bytes, checksum: 2b86e6de317dfb726f032a50b49bdb9d (MD5)
Previous issue date: 2000 / Resumo: Este trabalho verificou a adaptação das bases de prótese total superior, confeccionadas com resina acrílica termicamente ativada Clássico, sob a influência das variáveis prensagem e polimerização. Foram confeccionados quarenta modelos em gesso pedra, e os conjuntos modelo-base de cera foram divididos em quatro grupos de dez elementos e incluídos em muflas pela técnica de rotina, recebendo os tratamentos: Grupo 1- prensagem da resina e polimerização imediata em banho de água aquecida a 74°C por nove horas; Grupo 2- prensagem da resina acrílica e polimerização após seis horas, em banho de água aquecida a 74°C por nove horas; Grupo 3- prensagem da resina acrílica, utilização do dispositivo RS de contensão e polimerização imediata em banho de água aquecida a 74°C por nove horas; Grupo 4prensagem da resina acrílica, utilização do dispositivo RS de contensão e polimerização após seis horas, em banho de água aquecida a 74°C por nove horas. As bases de resina foram fixadas nos modelos com adesivo. Foram efetuados três cortes transversais, correspondentes à distal dos caninos (A), mesial dos primeiros molares (B) e região palatina posterior (C). O desajuste foi verificado com microscópio comparador (Leitz), em cinco pontos referenciais para cada corte. Os dados obtidos foram submetidos à análise estatística e ao teste de Tukey (5%). O dispositivo RS de contensão produziu níveis médios de adaptação (0,168 mm) com diferença estatística significativa (p<0,05) quando comparado com a prensagem convencional (0,215 mm), independente dos demais fatores.O dispositivo RS de contensão produziu níveis médios de adaptação (imediata = 0,173 mm e seis horas = 0,164 mm) com diferença estatística significativa (p<0,05) quando comparado com a prensagem convencional (imediata= 0,213 mm e seis horas= 0,216 mm). No fator corte, o dispositivo RS de contensão produziu valores (A = 0,140 mm, B= 0,183 mm e C= 0,256 mm) com diferença estatística significativa (p<0,05) quando comparado com a prensagem convencional (A= 0,151mm, B= 0,207 mm e C= 0,286 mm). Dentro do fator corte, a polimerização imediata produziu valores (A= 0,140 mm, B= 0,183 mm e C= 0,256 mm) sem diferença estatística significativa (p>0,05) quando comparada com a após seis horas (A= 0,193 mm, B= 0,187 mm e C= 0,244 mm). Independente dos demais fatores, os cortes A (0,140 mm), B (0,185 mm) e C (0,250 mm) foram diferentes estatisticamente entre si (p<0,05) / Abstract: The purpose of this study was to verify the denture base adaptation, made with Clássico heat-cured acrylic resin influenced by packing (conventional and RS tension system) and polymerization time (immediate and after 6 hours) variables. Forty stone plaster-acrylic resin base sets were randomly assigned in 4 groups of 10 elements and inc1uded in metallic frasks by routine technique, in order to receive the following experimental treatments: Group 1- acrylic resin packing and immediate polymerization in heated water at 74°C during 9 hours. Group 2- acrylic resin packing and polymerization after 6 hours in heated water at 74°C during 9 hours. Group 3acrylic resin packing using RS tension system and immediate polymerization in heated water at 74°C during 9 hours. Group 4- acrylic resin packing using RS contension system and polymerization after 6 hours in heated water at 74°C during 9 hours The resin bases were fixed on stone casts with instantaneous adhesive, and transversally cuts were made in the corresponding regions to distal of bicuspids (A), mesial of the first molars (B), and posterior palatal region (C). The dimensional alteration between acrylic resin base and stone plaster was verified with a comparator microscope at 5 referential points to each kind of cut. The data submitted to ANOV A and Turkey's test at 5% of significance level showed that the RS tension system produced better adaptation level (0.168 mm) with statistical significance (p<.05) when compared to conventional packing (0.215 mm), independently of other factors. For polymerization time, the RS tension system produced better adaptation level (immediate 0.173 mm and after 6 hours 0.164 mm) with statistical significance (p<.05) when compared to conventional packing (immediate 0.213 mm and after 6 hours 0.216 mm). In the cuts, the RS tension system produced values (A= 0.129 mm, B= 0.162 mm, and C= 0.214 mm) with statistical difference (p<.05) when compared to conventional packing (A= 0.151 mm, B= 0.207 mm, and C= 0.286 mm). The immediate cure showed values (A= 0.140 mm, B= 0.183 mm, and C= 0.256 mm) with no statistical difference (p>.05) when compared to those after 6 hours (A= 0.139 mm, B= 0.187 mm, and C= 0.244 mm). Independently ofthe other factors, the A (0.140 mm), B (0.185 mm), and C (0.250 mm) cuts showed values with significative statistical difference / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
67 |
Aderencia de Candida albicans, Cepa 12A, em tres materiais de revestimento resiliente para protese total, submetidos ou não a ciclagem termicaKina, Sidney 02 May 2001 (has links)
Orientador: Saide Sarckis Domitti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T22:22:53Z (GMT). No. of bitstreams: 1
Kina_Sidney_M.pdf: 3348251 bytes, checksum: fa871f0ac132f21ae41013ca2039119a (MD5)
Previous issue date: 2001 / Resumo: Este trabalho teve o objetivo de avaliar a adesão de leveduras (C. albicans, Cepa 12A) sobre a superfície de três materiais de revestimento resiliente, submetidos ou não à ciclagem térmica: MolloplastB@, Softliner@ e Eversoft@. Para tanto, foram confeccionados 24 corpos de prova com cada material, processados como indicado pelos fabricantes, que foram divididos em dois grupos, um sofrendo a ação de 1000 ciclos térmicos (1 minuto em banho a 5°C e 1 minuto em 65°C) e o outro não. Após a ciclagem térmica, todos os grupos foram esterilizados através de raios gama com dose de 25KGY. Posteriormente os corpos de prova foram submetidos ao teste de adesão utilizando-se para isso uma Cepa padrão para teste: C. albicans Cepa 12A. As leveduras foram cultivadas em meio de cultura a 3 t C por 18 horas, e então, coletadas em suspensão ajustada em espectofotômetro (Bauchse & Lamb) com 530 nm por 75% de transmitância. Os corpos de prova foram inoculados com 200 J.11 desta suspensão, e ficaram em estufa a 3tC sob agitação de 50 rpm durante uma hora. Após, as leveduras fracamente aderidas aos corpos de prova foram removidas através de lavagem em tubo com água miliQ. Foi preparada então, a solução para plaqueamento, através da lavagem fmal dos corpos de prova para remoção das leveduras fortemente aderidas. Este processo foi realizado com agitação em vortéx, por 30 segundos, com os corpos de prova imersos em 2 ml de STF, auxiliado ainda, por 1 grama de pérolas de vidro. Após, 100 J.11 desta suspensão foi plaqueada em ágar sabouraud, e guardadas em estufa a 37°C por 48 horas. Finalmente, processouse a contagem de colônias. Os resultados obtidos foram submetidos a análise de variância e corrigidos pelo método de Bonferroni. As diferenças dentro de cada um dos grupos com relação aos valores obtidos com e sem ciclagem térmica foram analisados usando Test- T de Student para amostras pareadas. O nível de significância estatística usado foi de 5%. Os resultados demonstraram diferença significante no Eversoft@, com e sem ciclagem térmica, quando comparado entre si e com os outros materiais, com nível de agregação de leveduras muito superior aos outros. O Molloplast-B@ após sofrer ciclagem térmica, apresentou maior tendência a adesão de leveduras, e quando comparada com o Softliner@ sem ciclagem térmica, não houve diferença estatística, porém, nos corpos ciclados térmicamente o material apresentou maior tendência a agregação de leveduras do que o Softliner@. O Softliner@ não demonstrou diferença com ou sem ciclagem térmica, e teve a menor tendência a agregação de C. albicans destes materiais / Abstract: The aim of the present thesis was to evaluate the adhesion of yeast (c. albicans CEPA 12A) on the surface of 3 different soft lining materiaIs, Molloplast-B@, Softliner@ and Eversoft@. The study included 24 samples of each material. The samples were divided into 2 groups: (i) samples which were thermal cyc1ed 1000 times, each cyc1e lasting 1 minute in SOC and 1 minute in 6SoC water bath and (ii) samples which were not exposed to thermal cyc1ing. Following sterilization in gama rays, the samples were tested for yeast adhesion to their surfaces using C. albicans CEPA 12A. The samples were incorporated to 200 _l of a solution containing the yeast suspension at 37°C for 1 hour. The yeast which were loosen attached to the material surface were removed by water rins e (miliQ). Finally, the samples were further rinsed to remove the yeast intimately attached to the material. 1 00 _l of the second rinsed water was applied to agar sabouraud and kept in a stove at 37°C for 48 hours. After that, the number of newly formed yeast colonies were assessed. The differences in the number of yeast colonies among the various groups were evaluated using Analyse of Variance and corrected by the method of Bonferroni. The differences within the same group regarding the effect of thermal cyc1ing was, however, evaluated by Student- T test for paired samples. The results from the present thesis demonstrated that the Eversoft samples showed a statistically significant larger number of yeast colonies with and without thermal cycling than the remaining groups. The Molloplast-B samples with thermal cyc1ing presented larger number of yeast colonies than the corresponding samples in the Softliner group while, there were no differences between the samples which were not thermal cycled in these groups. The Softliner samples demonstrated the lowest number of newly formed yeast colonies on their surface, with and without thermal cycling / Mestrado / Protese Dental / Mestre em Odontologia
|
68 |
Avaliação da dureza Knoop de dentes artificiais de resina acrilica submetidos a metodos de desinfecção quimica e por energia de micro-ondas / Knoop hardness of resin denture teeth after chemical and microwave disinfectionVasconcelos, Ligia Regina Mota de 02 December 2010 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T21:54:08Z (GMT). No. of bitstreams: 1
Vasconcelos_LigiaReginaMotade_M.pdf: 3171884 bytes, checksum: eb790eb8d7dcc5fe8ef341afb479af7c (MD5)
Previous issue date: 2010 / Resumo: O objetivo neste trabalho foi avaliar o efeito da desinfecção por soluções químicas de glutaraldeído a 2% e hipoclorito de sódio a 1% e por energia de micro-ondas sobre a microdureza Knoop de cinco marcas de dentes artificiais de resina acrílica das marcas Trilux (Ruthinium), Biocler (Pirassununga), Biotone (Dentsply), New Ace (Yamahachi) e Magister (Heraeus-Kulzer). Foram confeccionados cem amostras com dentes incisivos centrais e laterais inferiores das cinco marcas selecionadas, incluídos individualmente em blocos circulares de resina acrílica (Vip Wave), deixando a face vestibular exposta. Cinco amostras de cada marca comercial foram preparadas e submetidas à desinfecção química com soluções de hipoclorito de sódio a 1% e glutaraldeído 2%, desinfecção por micro-ondas e para o grupo controle. A desinfecção química foi realizada deixando as amostras em imersão nas soluções, em temperatura ambiente por 10 minutos, seguido de lavagem em água corrente por 30 segundos. A desinfecção simulada em micro-ondas foi feita em forno doméstico (Eletrolux) com potência de 650 W por 3 minutos, com as amostras imersas individualmente em 150 mL de água destilada. Os dentes foram analisados quanto à microdureza Knoop com microdurômetro (HMV-2000/Shimadzu) em três momentos: 1- antes dos procedimentos de desinfecção (controle), 2- depois do primeiro ciclo de desinfecção, e 3- depois do terceiro ciclo de desinfecção. Três endentações foram produzidas na área central da face vestibular dos incisivos. Os dados foram submetidos à análise de variância e ao teste de Tukey para comparação das médias em nível de 5% de significância. Os resultados mostraram que os valores de dureza Knoop não variaram significativamente para os tratamentos com soluções desinfetantes; porém, apresentaram variação estatística significante para a desinfecção simulada por micro-ondas, sendo mais evidente no Magister. O dente New Ace não apresentou alteração significativa com os tratamentos, sendo mais estável quando submetido aos processos de desinfecção / Abstract: The aim of this study was to evaluate the effect of disinfectant solutions of 2% glutaraldehyde and 1% sodium hypoclorite and microwave disinfection in Knoop hardness values of five brands of acrylic resin denture teeth Trilux (Ruthinium), Biocler (Pirassununga), Biotone (Dentsply), New Ace (Yamahachi) e Magister (Heraeus-Kulzer). One hundred specimens were produced using central and lateral lower acrylic denture teeth of the five brands selected which were individually positioned within tubes with heat-polymerized acrylic resin (Vip Wave), with buccal aspect exposed. Five specimens of each brand were submitted to each method of disinfection. The chemical method was made leaving the specimens immersed in the solutions for 10 minutes at room temperature and then rinsed with running water for 30 seconds. The microwave disinfection was realized in a microwave oven (Eletrolux; Amazonia Ltd., Manaus, AM), at 650 W for 3 minutes with the specimens individually immersed in 150 ml of distilled water. Knoop hardness test was performed using HMV- 2 (Shimadzu) with a 50g load for 15 seconds in three different moments: 1- before sterilization procedure, 2- sterilization procedure performed once and 3- sterilization procedure performed twice. The indentations were made in each specimen. Data were submitted to analysis of variance and Tukey's test at 5% of significance level. According to the results, no significant differences were found between materials and immersed solutions. However, a decrease in hardness was noticed after three simulated microwave disinfection was noticed in Magister brand teeth. New Ace showed the best hardness values after disinfection procedures / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
69 |
Avaliação da posição condilar em pacientes desdentados totais portadores de dentaduras duplas, através de planigrafias da ATMVinícius Carvalho Porto 25 April 2000 (has links)
A posição condilar tem sido questionada como importante fator na detecção de sinais e sintomas de DTM,s. Por muito tempo, determinou-se que a concentricidade condilar refletiria uma posição ótima para o paciente. No entanto, outros trabalhos mostraram que era possível a visualização da descentralização dos côndilos, mesmo em pacientes assintomáticos. Dessa forma, avaliou-se neste trabalho a posição condilar antes e após instalação de PT,s novas, por meio de planigrafias laterais da ATM. O critério de seleção dos pacientes foi aleatório e, mediante a amostra escolhida, foi preenchido um questionário clínico-anamnésico, seguido de tomadas radiográficas com o par de dentaduras antigas e novas em 12 pacientes. Um único examinador conduziu o preenchimento das fichas e análise das radiografias no programa de imagens Corel Draw 8. De acordo com a metodologia aplicada e análise estatística dos resultados, verificou-se que a posição condilar em desdentados totais na primeira tomada radiográfica situou-se mais para anterior em 100% dos casos. Já o deslocamento condilar após instalação das novas próteses resultou em uma tendência de deslocamento para posterior em 75% dos indivíduos, para anterior em 16,7% e em 8,3% não houve variação da posição condilar. Dos 18 côndilos (75% casos) com deslocamento para posterior, apenas 1 côndilo assumiu uma posição levemente posterior, tendo os demais se localizado concentricamente ou para anterior. Não houve qualquer correlação estatisticamente significativa entre variações das posições condilares e dimensões verticais de oclusão. Provavelmente, os deslocamentos condilares encontrados sejam justificados pelas manipulações com forças variadas, aplicada pelos profissionais, para a posição de trabalho (RC). Baseado na literatura, a tendência de localização para posterior possivelmente não irá causar danos aos pacientes, tendo em vista se tratarem de indivíduos assintomáticos. / Condyle position have been questioned as a relevant factor in detection of signs and symptoms of TMD. For a long time, it was determined that condylar concentricity would reflect an ideal position for the pacient. However, others studies demonstrated that it was possible to visualize that condyles were not always concentic in assintomatic pacient. This study evaluated the condylar position before and after instalation of new complete dentures using plain tomography of TMJ,s. Twelve completely edentulous patients were selected randomly to have new complete dentures. A questionare was filled out and plain tomograms were taken with old and new complete dentures inserted. Only one examiner evaluated the questionare and tomograms using Corel Draw 8 image software. According to the metodology and statical analysis, it was noted that condyle position in completely edentulous patients in the first tomogram was anterior in 100% of patients. After insertion of new dentures, the condyles had a tedency to be posteriorly positioned relative to the initial tomogram in 75% of the, 16,7% of the condyles deslocated anteriorly, and in 8,3% did not change position. Of the 18 condyles (75% of total) with posterior displacement, only one condyle assumed a true, although slight, posterior position, with the others located in a concentric or anterior position. There was no any statical correlation between variation of condylar position and vertical dimension of occlusion. Probably, the condylar displacement occurred due to variations in the manipulation technique applied by the professionals for centric relation registration. Base on the literature, the tendency to posterior location of condyles of completely edentulous patients after new complete dentures insertion will not cause any damage in assintomatic patients.
|
70 |
Avaliação da resistência ao cisalhamento de três sistemas de núcleos intra-radicularesAnuar Antônio Xible 26 April 2000 (has links)
Foram comparadas as resistências adesivas ao cisalhamento presente entres os componentes de três diferentes sistemas de núcleos intra-radiculares. Foram utilizados pinos de cerâmica à base de dióxido de zircônia ( Cosmopost ), e pinos de titânio ( Tenax ). Os preenchimentos testados foram a resina composta fotopolimerizável ( Tetric Ceram ) e porcelana vítrea fundível ( IPS Empress Post ). Foram confeccionados 30 espécimes divididos em 03 grupos: 10 espécimes de pinos de cerâmica à base de zircônia, aos quais foi fundida porcelana vítrea; 10 espécimes de pinos de cerâmica à base de zircônia e resina composta fotopolimerizável; e 10 espécimes de pinos de titânio e resina composta fotopolimerizável, todos, de acordo com o fabricante. Os espécimes do grupo 1 necessitaram ser ajustados, por desgaste, à base de prova. Todos foram submetidos a uma força de cisalhamento em uma máquina de ensaios universal Kratos, até fratura. A análise estatística, assim como observações macroscópicas permitiu-nos concluir que: 1- A resistência encontrada entre os componentes dos corpos de prova do grupo Pino de Zircônia X Cerâmica IPS Empress Post apresentou resultados estatisticamente não significantes em relação ao grupo em que foi usado Pinos de Titânio X Resina composta. 2- Os resultados dos sistemas do grupo 1 - Pino de Zircônia X Cerâmica IPS Empress Post - e 3 - Pinos de Titânio X Resina Composta demonstraram diferença estatisticamente significante em relação ao grupo 2, em que foi empregado o sistema dos Pinos de Zircônia X Resina Composta. / The purpose of the present study was to evaluate shear bond strength in three different posts and core systems. Thirty standardized cylindrical cores with 4mm height and 6mm diameter were prepared surrounding the posts in a special prefabricated device. They were divided in three groups. Group 1 was composed of 10 zirconia posts ( Cosmopost Ivoclar ), which were placed in a special device. Cylinders were waxed surrounding them. The patterns were then invested and glass-ceramic ( Empress Cosmo Ivoclar ) was heat-pressed in a EP500 furnace ( Ivoclar ). Group 2 consisting of 10 zirconia posts ( Cosmopost Ivoclar ) adapted in the device and composite ( Tetric Ceram Ivoclar ) was inserted and then light activated. Group 3 consisting of titanium posts ( Tenax Whaledent ) was adapted in the same device as group 1 and 2. The same composite was inserted and also light activated. Specimens were tested for shear bond strength in a Kratos universal test machine. Results showed no statistical differences between groups 1 and 3 but significant difference between group 2 and the others. According to above results, it was concluded that systems used in groups 1 and 3 are the most reliable in clinical applications.
|
Page generated in 0.034 seconds