21

Analise do comportamento do som articular em individuos com alterações funcionais do sistema estomatognatico, tratados com aparelhos oclusais planos

Oliveira, Isabel Toscanelli de 09 December 2000 (has links)
Orientadores : Wilkens Aurelio Buarque e Silva, Fausto Berzin / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T06:46:55Z (GMT). No. of bitstreams: 1 Oliveira_IsabelToscanellide_M.pdf: 3538607 bytes, checksum: 96c8296e27d54b7c085b5bdd45125e6f (MD5) Previous issue date: 2000 / Resumo: As alterações funcionais do sistema estomatognático têm sido objeto de observações e estudo em diversas áreas da odontologia. Os sons emitidos pelas articulações temporomandibulares durante a função mastigatória, constituem-se em um dos sinais mais prevalentes deste quadro patológico. O objetivo desta pesquisa foi estudar o comportamento do som articular, no que concerne a sua intensidade e reprodutibilidade, através de avaliações eletrosonográficas, ausculta e escala visual analógica, em pacientes portadores de alterações funcionais do sistema estomatognático, tratados com aparelhos de cobertura oclusal plana. Para a realização da pesquisa, foram selecionados dez pacientes, os quais foram submetidos às avaliações previstas na ficha clínica do CETASE. Todos os voluntários utilizaram aparelhos de cobertura oclusal plana, por um período de 240 dias, onde foi observada a remissão da sintomatologia inicial e, o comportamento dos sons articulares sob três aspectos: o relato clínico do paciente, através de uma escala analógica visual; a ausculta e a eletrosonografia computadorizada. Em função da metodologia proposta e dos resultados obtidos, concluímos que: houve uma redução na intensidade e reprodutibilidade dos sons articulares em todos os parâmetros analisados; as avaliações eletrosonográficas computadorizadas, permitiram a análise dos ruídos articulares em níveis abaixo dos limites do ouvido humano e que; a terapia com aparelhos de cobertura oclusal plana, foi efetiva para a remissão da sintomatologia apresentada inicialmente pelos pacientes / Abstract: The Functional Alterations of Stomathognatic System had been the aim of study in various areas in dentistry. The articular sounds emitted during the masticatory function, are important indications of this pathology. The aim of this research, were to study the articular noise comportment in intensity and reproducibility, through electrosonographic evaluations, auscultation and clinical report, in patients with temporomandibular disorders, treated with plain occlusal splints. Ten patients were selected and submitted to the evaluations includes in CET ASE clinical fickle. Ali of them used plain occlusal splints for a period of 240 days, where were observed the symptomatology decrease and the comportment of the articular noise in three aspects: the clinical report, through an analogical visual scales, auscultation and computerized electrosonographic evaluations. The obtained results permitted to conclude that: there were a decrease in intensity and reproducibility of the articular noise in ali of the parameters analyzed; the computerized electrosonographic evaluations permitted an analyze of the articular sounds in levels down of the limits of the human ear and that, the plain occlusal splints therapy were effective to the remission of the symptomatology presented initially for the patients / Mestrado / Protese Dental / Mestre em Clínica Odontológica
22

Analise do assentamento passivo de infra-estruturas em titanio e liga de paladio-prata, fundidas em monobloco e submetidas a soldagem a laser

Sousa, Samira Albuquerque de 03 September 2001 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T21:28:19Z (GMT). No. of bitstreams: 1 Sousa_SamiraAlbuquerquede_M.pdf: 13576811 bytes, checksum: 7e60e73bfad677f2750d67484e369966 (MD5) Previous issue date: 2001 / Resumo: Este estudo se propôs avaliar o assentamento passivo de infra estruturas fundidas em titânio e liga de paládio-prata, confeccionadas pela técnica monobloco e soldagem à laser. A partir de uma matriz metálica com cinco implantes (3,75 X 13mm), obteve-se um modelo mestre onde foram incorporadas réplicas de implantes em aço inoxidável, e então foram realizados os procedimentos de enceramento, inclusão e acabamento das estruturas metálicas. Foram enceradas 20 amostras, padronizadas em forma e tamanho, sendo 10 fundidas em titânio comercialmente puro (Rematitan-Dentaurum, Pforzhein-Germany) e 10 em liga de paládio-prata (Pors-on 4-Degussa). As amostras foram divididas em 04 grupos, sendo: Grupo I: 05 estruturas fundidas em peça única em liga de paládio-prata; Grupo II: 05 estruturas fundidas em liga de paládio-prata, previamente seccionadas e submetidas à soldagem a laser; Grupo III: 05 estruturas fundidas em peça única de titânio e Grupo IV: 05 estruturas fundidas em titânio, previamente seccionadas e submetidas à soldagem a laser. As análises e mensurações das interfaces foram efetuadas tanto nas peças em monobloco quanto nas soldadas a laser, utilizando microscópio mensurador (STM Digital - OLYMPUS - Japan). Sendo as mesmas efetuadas na região vestibular (V) e lingual (L) da interface implante/prótese dos três implantes previamente denominados com letras A, C e E. Os dados foram submetidos análise de variância e ao teste de Tukey (p<0,05). Os resultados indicaram que: as estruturas fundidas em monobloco nos cilindros centrais apresentaram maior interface (desajuste médio de 151,392 mm) que as soldadas a laser (34,739 mm). Também foram encontradas diferenças estatisticamente significantes entre os materiais utilizados, sendo que a liga de paládio-prata (66,301 mm) apresentou melhores resultados que o titânio (119,831 mm). Nos cilindros distais, os resultados mostraram não haver diferenças estatisticamente significantes entre as estruturas fundidas em titânio e paládio-prata, na técnica monobloco. No entanto, foram encontradas diferenças estatisticamente significantes entre os dois materiais, após a soldagem a laser, sendo que o titânio (31,37 mm) apresentou melhores resultados que a liga de paládio-prata (106,59 mm). Houve também diferenças estatisticamente significantes entre as técnicas monobloco e soldagem a laser para ambos os materiais, sendo os melhores resultados para a técnica de soldagem à laser / Abstract: The aim of this study was to evaluate passive fit in titanium and palladium-silver, made by the one-piece casting technique and laser welding. By means of a metallic matrix containing five implants (3.75 X 13mm), a master model was obtained and implant replies were incorporated into it, then, wax up, inclusion and polishing was performed in the metallic structures. Twenty standardized samples, in shape and size, were waxed up; ten samples were cast in commercially pure titanium (Rematitan Dentaurum, Pforzhein-Germany), the other ten specimens were cast in palladium-silver alloy (Pors-on 4-Degussa). The samples were separated in four groups: Group I: five single structures cast in palladium-silver alloy; Group II: five structures, that were previously sectioned and underwent to laser welding, were cast in palladium-silver alloy; Group III: five single structures that were cast in titanium; and Group IV: five structures, that were previously sectioned and underwent to laser welding, were cast in titanium. The interfaces evaluations and measurements were performed both in one-piece castings and the laser welded structures, using a microscope. Data were submitted to ANOVA and Tukey's test (p<0.05). According to the results, one-piece casting structures showed higher interface (mean desajustment of 151.392 mm) in comparison to the structures welded in laser (34.739 mm). Concerning the materials, it was also found statistically significant difference, palladium-silver alloy (66.301 mm) showed better results than titanium (119.831 mm). In relation to the distal cylinders, the structures cast in titanium and palladium-silver alloy didn't present statistically significant differences, for the one-piece casting technique. However, statistically significant differences between these materials were found after laser welding. Titanium presented better results (31.37 mm) compared to palladium-silver alloy (106.59 mm). With respect to the one piece casting and laser welding techniques, there were also statistically significant differences between this two materials / Mestrado / Protese Dental / Mestre em Clínica Odontológica
23

Estudo cefalometrico do posicionamento de dentes artificiais em proteses totais duplas confeccionadas pela tecnica da zona neutra

Silva, Almenara de Souza Fonseca 03 August 2001 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T08:34:54Z (GMT). No. of bitstreams: 1 Silva_AlmenaradeSouzaFonseca_D.pdf: 4253050 bytes, checksum: 24c4e76e39bad8efc60fb7555a293658 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar a posição ocupada pelos dentes artificiais em próteses totais duplas confeccionadas pela técnica da Zona Neutra, por meio de análises cefalométricas e posteriormente, comparar os dados obtidos com os padrões considerados como normais para indivíduos dentados. Foram avaliados 28 indivíduos saudáveis, previamente reabilitados com próteses totais duplas, do sexo feminino, raça branca, com idade variando entre 55 e 65 anos e que não apresentavam sinais e sintomas clínicos de desordens temporomandibulares. Após a instalação das próteses e o período de adaptação, foram tomadas duas telerradiografias, uma em norma frontal e outra lateral, em oclusão cêntrica, com as superfícies dentárias previamente marcadas com uma substância de contraste radiográfico. Posteriormente foram executados traçados cefalométricos pelo método manual e realizadas as mensurações lineares e angulares correspondentes aos parâmetros considerados de importância para o trabalho. Os resultados foram analisados utilizando-se o intervalo de confiança para a média ao nível de 95%, sendo esses intervalos comparados com os padrões de normalidade estabelecidos pelas análises, indicando assim, diferenças significativas ou não. Os valores médios referentes à posição ântero-posterior dos incisivos centrais superior (99,84mm) e inferior (97,39mm); a inclinação do incisivo inferior em relação à mandíbula (93,89°); a dimensão transversal inter-molares (53,91mm) e a relação dos primeiros molares inferiores esquerdo (10,79mm) e direito (10,45mm) em relação ao complexo maxilomandibular não apresentaram diferença significativa, considerando-se o intervalo de confiança de 95% para a média, quando comparados com os padrões de normalidade, que eram respectivamente: 94,1mm '+ OU ¿' 5,05; 90,0mm '+ OU ¿' 5,33; 90° '+ OU ¿' 5; 54mm '+ OU ¿' 2 e 11,6mm '+ OU ¿' 2, para ambos os lados. A inclinação do incisivo central superior em relação à maxila (98,79°) e a posição ântero-posterior do primeiro molar superior (23,41mm), quando comparadas ao padrão de normalidade, que era respectivamente de 112° '+ OU ¿' 6 e 18mm '+ OU ¿' 3, foram significativamente diferentes, considerando-se uma confiança de 95%. Foi observada uma correlação negativa ('alfa¿ '< OU =¿ 0,01) entre o ângulo goníaco e a inclinação do incisivo central inferior em relação à mandíbula. Pôde-se concluir que os dentes artifíciais montados em próteses totais duplas, confeccionadas pela técnica da Zona Neutra encontram-se em uma posição vestíbulo-língual compatível com aquela ocupada pelos dentes naturais e os dentes anteriores inferiores apresentam uma redução na inclinação à medida que ocorre o aumento nos valores do ângulo goníaco, seguindo a mesma tendência observada em indivíduos dentados / Abstract: The object of this study was to evaluate the artificial teeth position in double complete dentures constructed by Neutral Zone technique, through cephalometrics analysis and then to compare the data obtained to cephalometrics standards considered as normal for dentate subjects. Twenty eight healthy subjects, of female sex, white race, who received double complete dentures, with range in age from 55 to 65 years and without signs and symptoms of temporomandibular dysfunction were evaluated. After insertion of dentures and the adaptation period, two teleradiographys, at frontal and lateral norms were made in centric occlusion, with the dental surfaces previously marked with a radio-opaque substance. They were made cephalometrics tracing by manual method and obtained the linear and angular measurements of the parameters considered important for the work. The results were analyzed by onfidence interval for the average at levei of 95% and these intervals were compared to cephalometrics standards, showing the significant difference or not. The average of the anteroposterior position of the upper central incisor (99.84mm) and lower (97.39mm); the inclination of lower incisor to the mandibula (93.89°); the intermolar width (53.94mm) and the relation of left lower first molar (10.79mm) and right (10.45mm) to fronto denture plane did not show any significant difference, by 95% confidence interval, when compared to cephalometrics standards, which are respectively 94.1mm '+ or ¿' 5.05; 90.0mm '+ or¿' 5.33; 90° '+ or ¿' 5; 54mm '+ or ¿' 2 e 11.6mm '+ or ¿' 2 for both side. The inclination of upper incisor to maxilla (98.79°) and the anteroposterior position of the upper first molar (23.41mm), when compared to standards, that are respectively 112° '+ or ¿' 6 and 18mm '+ or ¿' 3, were significant different, by confidence of 95%. It was found a negative correlation ('alfa¿ '< or =¿ 0.01) between gonial angle and inclination of lower central incisor to mandibula. It could conclude that the artificial teeth arranged in double complete dentures constructed by Neutral Zone technique are in a buccolingual position compatible with that occupied for the natural teeth and the lower anterior teeth presented a decrease inclination as increase the values of gonial angle, following the same tendency observed in dentate subjects / Doutorado / Protese Dental / Doutor em Clínica Odontológica
24

Efeito de agentes quimicos para limpeza de proteses sobre a alteração de peso de material reembasador resiliente temporario

Feitosa, Maria Aurea Lira 13 February 2001 (has links)
Orientadores: Altair A. Del Bel Cury, Renata Cunha Matheus R. Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T13:10:53Z (GMT). No. of bitstreams: 1 Feitosa_MariaAureaLira_M.pdf: 10196962 bytes, checksum: 10b8701068a6ffafaae9228fdc228ae2 (MD5) Previous issue date: 2001 / Resumo: O objetivo desta pesquisa foi avaliar a alteração de peso do material reembasador resiliente temporário Coe-80ft quando armazenado em saliva artificial e submetido a tratamentos com os agentes químicos para limpeza de próteses Polident e Efferdent. Assim, foram confeccionadas 48 amostras do material resiliente que foram divididas aleatoriamente em quatro grupos, dois experimentais (G3 e G4) e dois controles (G1 e G2) e armazenadas em saliva artificial à temperatura de 37 ± 2°C durante todo o período estudado. As amostras dos grupos experimentais foram imersas diariamente nas soluções de Polident (G3) e Efferdent (G4), por 5 e 15 minutos, respectivamente e, as dos grupos-controle (G1 e G2) em água, por um período de 15 dias. As avaliações de peso foram realizadas imediatamente após confecção das amostras (To), após 24 horas (T1), com 7dias (T2) e 15 dias (T3). Os resultados (médias ± dp)para a perda de peso do material (mg) comparando-se os grupos em cada tempo (letras maiúsculas) e a influência do tempo (letras minúsculas) para cada grupo foram: G1=2,71 ± 0,08Aa; 2,65 ± 0,08Ab; 2,63 ± 0,08Abc; 2,60 ± 0,11Ac; G2=2,66 ± 0,08Aa; 2,61 ± 0,09Ab; 2,58 ± 0,08Ac; 2,57 ± 0,08Ad; G3=2,65 ± 0,14Aa; 2,60 ± 0,14Ab; 2,58 ± 0,14Ac; 2,57 ± 0,14Ad; G4=2,63 ± 0,11Aa; 2,58 ± 0,11Ab; 2,55 ± 0,11Ac; 2,54 ± 0,11Ad. Médias seguidas de letras distintas diferem estatisticamente entre si (p<0,05) pelo teste de Tukey. Com base nos resultados obtidos foi possível concluir que o material reembasador resiliente Coe-Soft quando imerso em saliva artificial perdeu peso antes do início do tratamento com os agentes químicos para limpeza da próteses e esta perda prosseguiu durante todo o período estudado, independentemente do tratamento empregado / Abstract: The purpose of this study was to evaluate the weight variation of Coe-80ft resilient material when stored in artificial saliva and submitted to treatments with Polident and Efferdent chemical denture cleansers. Forty-eight samples made of resilient material were divided, randomly, in four graups: two experimental (G3 and G4) and two contrai graups (G1 and G2), that were immersed in artificial saliva and kept at 37 ± 2°C temperature during the whole period of the study. The samples of the experimental graups were immersed daily in Polident or Efferdent solutions for 5 and 15 minutes, respectively, and the samples of the contrai were immersed in water, during a period of 15 days. The rates of weight were accomplished just after the samples were made (To), after 24 hours (T 1), with 7 days (T2) and 15 days (T3). The results (means and standard deviation) for the weight loss of material (mg) comparing the graups in each time (capitalletters) and the influence of time (small letters) for each graup were: G1=2,71±0,08Aa; 2,65 ± 0,08Ab; 2,63 ± 0,08Abc; 2,60 ± 0,11Ac; G2=2,66 ± 0,08Aa; 2,61 ± 0,09Ab; 2,58 ± 0,08Ac; 2,57 ± 0,08Ad; G3=2,65 ± 0,14Aa; 2,60 ± 0,14Ab; 2,58± 0,14Ac; 2,57 ±0,14Ad; G4=2,63 ±0, 11Aa; 2,58 ±0,11Ab; 2,55 ± 0,11Ac; 2,54 ± 0,11Ad. Means followed by different letters are statistically different themselves (p<0,05) by Tukey test. Based on these results it was possible concluded that the Coe-Soft liner resilient, when it is immersed in artificial saliva it lost weight before the beggining of 3 treatment with cleanser agents for dentures and the weight loss proceded during ali the time studied period, independently of the treatment used. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
25

Função oral e qualidade de dieta : influencia de fatores estomatognaticos e socio-demograficos

Shinkai, Rosemary Sadami Arai 18 October 2001 (has links)
Orientador : Altair A. Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:17:27Z (GMT). No. of bitstreams: 1 Shinkai_RosemarySadamiArai_D.pdf: 3978741 bytes, checksum: bb292ede4a32f6dd1d01afd036dc453b (MD5) Previous issue date: 2001 / Resumo: Estudos anteriores sobre o impacto da saúde bucal e da função oral na escolha e ingestão de alimentos apresentaram resultados contraditórios. Este trabalho, composto por três manuscritos, teve por objetivo explorar a relação entre função oral e qualidade de dieta em indivíduos com diferentes tipos de condições bucais. O primeiro capítulo estudou a influência de variáveis mastigatórias e de fatores sócio-demográficos na qualidade de dieta de indivíduos dentados e edentados. O segundo artigo avaliou se a deficiência técnica de próteses totais em termos de retenção, estabilidade e desgaste de dentes artificiais está relacionada à diminuição da performance mastigatória, à percepção de dificuldades em mastigar e à qualidade de dieta insatisfatória. O terceiro manuscrito abordou a relação entre função mastigatória, qualidade de dieta e problemas digestivos em pacientes de cirurgia ortognática. Os resultados destes estudos demonstraram que a qualidade de dieta não foi determinada pelas condições oclusais ou pelo grau de função oral. Quanto pior as condições oclusais, pior é a eficiência de função oral em termos de performance mastigatória e força de mordida. Em relação a próteses totais, próteses com qualidade técnica adequada permitiram um desempenho funcional superior às próteses com deficiências técnicas. Entretanto, não há reflexo na percepção de capacidade mastigatória ou na qualidade de dieta e adequação nutricional. Independentemente das condições oclusais, da qualidade técnica das próteses totais ou do grau de função oral, a maioria dos indivíduos apresentou qualidade de dieta deficiente / Abstract: Previous studies about the impact of oral health and oral function on diet and food choices have shown contradictory results. This study, which is composed by three manuscripts, aimed to explore the relationship between oral function and diet quality in subjects with different oral conditions. The first chapter studied the influence of masticatory and sociodemographic variables on diet quality of dentate and edentulous subjects. The second paper evaluated if poor quality of complete dentures, in terms of retention, stability, and artificial tooth wear, is related to decreased masticatory performance, perceived difficulties in ability to chew, and poor diet quality. The third manuscript analyzed the relationship among oral function, diet quality, and digestive problems in orthognathic surgery patients. The results of these studies showed that diet quality was determined neither by occlusal conditions nor by the leveI of oral function. The worse the occlusal conditions, the worse the efficiency of oral function regarding masticatory performance and bite force. In relation to complete dentures, good quality complete dentures allowed superior functional performance compared to poor quality prostheses. However, this did not reflected in perception of masticatory ability or in diet quality and nutrition adequacy. The majority of subjects had deficient diet qualities independently of occlusal conditions, technical quality of complete dentures, and level of oral function / Doutorado / Protese Dental / Doutor em Clínica Odontológica
26

Analise da deformação de componentes de protese fixa implantossuportada quando submetidos a cargas axiais e obliquas por meio de extensometria / Analysis of the deformation of the components of implant-suported prosthesis when submitted to axial and obliques loads by mean of the extensometry

Costa, Marcelo de Almeida 02 November 2009 (has links)
Orientador: Wilkens Aurelio Buarque e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T03:30:15Z (GMT). No. of bitstreams: 1 Costa_MarcelodeAlmeida_D.pdf: 2169259 bytes, checksum: 40e31d0384a05e3f5b7c97d6657b6364 (MD5) Previous issue date: 2009 / Resumo: Este trabalho teve como objetivo, avaliar através da extesometria, a resposta de forças aplicadas sobre abutments de infra-estrutruras implanto-retidas fundidas em ligas de cobalto-cromo, pela técnica de monobloco, simulando caso de protocolo mandibular, foram utilizados 06 implantes com distância de 10 mm entre implantes e com extremo livre Cantilever bilateral com tamanho do 20 mm. Em cada abutment foram colados 04 extensometros, fazendo uma ponte de Wheatstone, após apertamento de todos os componentes a peça em monobloco, foi submetido a um ensaio mecânico com cargas compressivas com valores de 150 N/cm, analisando quantitativamente os dados através da extensômetria, permitindo resultados bem precisos. Os referidos resultados foram obtidos usando os maiores valores registrados em cada ponto de força aplicado, ou seja, nos lados: esquerdo e direito ( cantilever bilateralmente), tanto para carga axial ou em 20º, demonstrou pura deflexão, porem quando a aplicação foi entre as fixações( implantes ) P1eP2,P3eP4,P4 eP5, P5eP6, respectivamente, foi obtido nas fixações mais próximas a aplicação da carga um maior grau de compressão (deflexão) e nas fixações mais distantes uma pequena deflexão negativa indo até conseguir uma deflexão positiva, sugerindo movimento de gangorra / Abstract: The objective of this study was evaluate through extensometry the response of implant-suported frameworks in cobalt-chromium submitted to a load by the technique of monoblock, that simulate a case of mandibular protocol with 06 implants with a distance of 10 mm between each implant and a bilateral cantlever of 20 mm. In each abutment were pasted 04 strain gauges, making a bridge of Wheatstone, after squeezing all components of the piece of the monoblock, was submitted to a test with mechanical compressive loads with values of 150 N, quantitatively analyzing the data through extensometry, allowing accurate results. The results were obtained using the highest values recorded at each point of force applied, in the points L and R (cantilever bilaterally) for both axial load or 20, showed pure deflection, but when the load was applyed between p1 and p2, P3eP4, P4 eP5, P5eP6 respectively, was obtained a greater degree of compression (deflection) closer to the application of the load and more dstant to the applicarion of load, a little negative deflection was found by going to a positive deflection, suggesting movement of seesaw / Doutorado / Protese Dental / Doutor em Clínica Odontológica
27

Dimensão vertical de oclusão em desdentados totais obtida pelos métodos de Tamaki de Beresin & Schiesser: estudo comparativo.

Rudys Rodolfo De Jesus Tavarez 08 August 1997 (has links)
A dimensão vertical de oclusão obtida pelos métodos de Tamaki e de Beresin & Schiesser; e a altura das próteses que os pacientes utilizavam, foram determinadas em uma amostra de 30 pacientes desdentados totais superior e inferior, com idade entre 38 e 77 anos; apresentando prótesis totais duplas totais em uso por um período mínimo de cinco anos, rebordos alveolares clinicamente favoráveis, ausência de sintomas de desordens temporomandibulares, com movimentos mandibulares normais. Os valores obtidos em cada um dos métodos testados foram comparados e relacionados com as alturas encontradas nas próteses que os pacientes utilizavam. Os resultados obtidos permitiram concluir que: 1) houve diferença estatisticamente significante em nível de 0,01 %, quando se compararam os valores obtidos pelos dois métodos; 2) quando comparados os métodos de Tamaki e Beresin & Schiesser em relação as alturas das próteses utilizadas, pode-se observar uma diferença média positiva de 3,02mm e 4,40mm respectivamente. / The vertical dimension of oclussion obtained by Tamaki’s and Beresin & Schiesser’s methods and the height of the complete dentures used by the patiens were obtained in a 30 edentulous persons sample with ages ranging from 38 to 77 years old, that had been wearing superior and inferior complete dentures for at least 5 years, in hose residual ridges were clinically favorable, and showing normal mandibular movements and absence of temporomandibular disordens. The purpose of this study was comparing the values obteined in each of the tested methods and correlating them with the heights taken of the dentures usedby the patients. As so checking the correspondence grade existing in each one. The results showed that: 1) There was statistically significant difference when comparing the values obteined in the two methods; being that there was a great correlation between these values to the leve of 0,01 %; 2) When comparing Tamaki’s and Beresin & Schiesser’s methods in relation to the heights of dentures used, a positiver medium difference could be observed, of 3.02mm and 4.40mm respectively.
28

Movimentação linear de dentes em protese total superior sob influencia dos tipos de prensagem e desinclusão

Consani, Rafael Leonardo Xediek, 1974- 15 August 2002 (has links)
Orientador : Saide Sarckis Domitti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T21:16:24Z (GMT). No. of bitstreams: 1 Consani_RafaelLeonardoXediek_D.pdf: 8126101 bytes, checksum: cd80ac9be45431a4717330a4c63fb7d8 (MD5) Previous issue date: 2002 / Resumo: O propósito deste estudo foi verificar a movimentação linear dos dentes em prótese total superior, confeccionada com resina acrílica ativada termicamente clássico, polimerizada em água a 74°C por 9 horas, após 12 horas da prensagem final, sob a influência do tipo de prensagem (convencional e RS) e da desinclusão (esfiiamento em água e em água mais bancada por 3 horas). Quarenta conjuntos modelo-base de prova de cera, com dentes artificiais, foram separados aleatoriamente em quatro grupos de dez conjuntos e incluídos em muflas metálicas pela técnica de rotina, a fim de receber os tratamentos experimentais: Grupo 1- prensagem convencional, polimerização em água a 74°C por 9 horas, iniciada após 12 horas da prensagem final e desinclusão após esfiiamento em água. Grupo 2- prensagem convencional, polimerização em água a 74°C por 9 horas, iniciada após 12 horas da prensagem final e desinclusão após esfiiamento em água e bancada por 3 horas. Grupo 3- prensagem RS, polimerização em água a 74°C por 9 horas, iniciada após 12 horas da prensagem final e desinclusão após esfiiamento em água. Grupo 4- prensagem RS, polimerização em água a 74°C por 9 horas, iniciada após 12 horas da prensagem final e desinclusão após esfiiamento em água e bancada por 3 horas. As distâncias I-I, PM-PM, M-M, ID-MD e lEME foram mensuradas antes e depois da polimerização da base, com microscópio comparador linear (Olympus), com precisão de 0,0005 mm. Os resultados submetidos à análise de variância e ao teste de Tukey em nível de 5% de significância mostraram que: a) Fator polimerização: não houve diferença estatística significativa nas distâncias transversais I-I, PM-PM e M M em todas interações; nas distâncias ântero-posteriores ID-MD e IE-ME na prensagem convencional com desinclusão após esfiiamento em água; e na prensagem RS com desinclusão após esfiiamento em água mais bancada por 3 horas. Houve diferença estatística significativa nos valores das distâncias ID-MD e IE-ME na prensagem convencional com desinclusão após esfriamento em água mais bancada por 3 horas e na prensagem RS com esfriamento em água. b) Fator prensagem: as distâncias I-I, PM-PM e M-M não apresentaram diferença estatística significativa em todas as interações. O mesmo aconteceu nas distâncias ID-MD e IE-ME antes da polimerização com desinclusão após esfriamento em água; após polimerização com desinclusão após esfriamento em água; e antes da polimerização com desinclusão após esfriamento em água mais bancada por 3 horas. Houve diferença estatística significativa nos valores das distâncias ID-MD e IE-ME após polimerização com desinclusão após esfriamento em água mais bancada por 3 horas. c) Fator desinclusão: as distâncias I-I, PM-PM, M-M, ID-MD e IE-ME foram sem diferença estatística significativa em todas as interações / Abstract: The purpose of this study was to verify the linear teeth movement in maxillary denture made with Clássico heat -cured acrylic resin, polymerized in water at 74°C for 9 hours, 12 hours after the detinitive flask closure, and influenced by pressing (conventional and RS) and deflasking (water cooling and water-cooling plus bench for 3 hours). Forty stone casts-wax plate base with teeth were randomly assigned in 4 groups of 10 elements and included in metallic frasks by routine technique, in order to receive the following experimental treatments: Group 1- conventional pressure, polymerization in water at 74°C for 9 hours, starting 12 hours after the detinitive pressure and deflasking after water-cooling. Group 2- conventional pressure, polymerization in water at 74°C for 9 hours, starting 12 hours after the definitive pressure and deflasking after water-cooling and bench for 3 hours. Group 3- RS pressure, polymerization in water at 74°C for 9 hours, starting 12 hours after the definitive pressure and deflasking after water-cooling. Group 4- RS pressure, polymerization in water at 74°C for 9 hours, starting 12 hours after the detinitive pressure and deflasking after water-cooling and bench for 3 hours. The I-I, PM-PM, M-M, RI-RM and LI-LM distances were determined before and after base polymerization, with a linear comparator microscope (Olympus), with tolerance of 0.0005 mm. The data submitted to ANOV A and Turkey's test at 5% of significance leveI showed that: a) Polymerization factor: there was no statistically significant difference in the lI, PM-PM and M-M distances in all interactions. The same was showed in the RI-RM and LI-LM distances in the conventional pressure with deflasking after water-cooling, and in the RS pressure with deflasking after watercooling plus bench for 3 hours. There was statistically significant difference in the RI-RM and LI-LM distance values in the conventional pressure with deflasking afier water-cooling plus bench for 3 hours, and in the RS pressure with deflasking afier water-cooling. b) Pressure factor: the I-I, PM-PM, M-M distances was no statistically significant difference in alI interactions. The same occurred in the RI-RM and LI-LM distances before and afier poIymerization with deflasking afier water-cooIing, and before poIymerization with deflasking afier water-cooIing pIus bench for 3 hours. There was statisticaUy significant difference in the RI-RM and LI-LM distances afier poIymerization with deflasking afier water-cooling pIus bench for 3 hours. c) Deflasking factor: The I-I, PM-PM, M-M, RI-RM and LI-LM distances were no statisticalIy significant difference in alI interactions / Doutorado / Protese Dental / Doutor em Clínica Odontológica
29

Adaptação das bases de protese total superior sob influencia da interação gessos de inclusão e tempos pos-prensagem da resina acrilica

Sousa, Rodrigo Luiz dos Santos 13 November 2002 (has links)
Orientadores: Saide Sarckis Domitti, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:30:06Z (GMT). No. of bitstreams: 1 Sousa_RodrigoLuizdosSantos_M.pdf: 2175263 bytes, checksum: 6428bbb672d90b7979afa066cfb2be84 (MD5) Previous issue date: 2002 / Resumo: Este trabalho avaliou a adaptação das bases de prótese total superior sob efeitos da combinação de gessos de inclusão (tipos II x III e tipos II x IV) e dos tempos pós-prensagem (imediato e 24 horas), confeccionadas com resina acrílica ativada termicamente Clássico, polimerizada em água aquecida a 74°C por 9 horas. Foram confeccionados modelos de gesso pedra tipo III, e sobre eles bases com duas lâminas de cera de 0,9 mm. Após o processamento das bases pela técnica de rotina, o conjunto modelo de gesso-base de resina foi fixado num dispositivo para seccionamento transversal, e foram feitos três cortes correspondentes às regiões de distal de caninos (A), mesial dos primeiros molares (B) e região palatina posterior (C). O nível de adaptação foi mensurado com auxílio do microscópio comparador linear Olympus, com capacidade de medição de 0,0005 mm. Os dados submetidos à análise de variância e ao teste de Tukey (5%) mostraram que não houve diferença estatística significativa (p<0,05) entre as combinações de gesso tipo II x tipos III (0,224 mm) e IV (0,238 mm). O tempo pósprensagem imediato (TO) produziu níveis médios de adaptação (0,257 mm) com diferença estatística significativa (p<0,05) quando comparado ao tempo pós-prensagem de 24 horas (T24) (0,205 mm). O menor nível de desadaptação foi obtido pela combinação gesso II x III no tempo de 24 horas (0,183 mm). Independente dos demais fatores, o maior nível de desadaptação ocorreu no corte C (0,285 mm), seguido dos cortes B (0,231 mm) e A (0,179 mm), havendo diferença estatística significativa (p<0,05) entre eles. Na combinação gesso II x III, a menor média de desajuste ocorreu no corte A (0,181 mm), com diferença estatística significativa (p<0,05) em relação aos cortes B (0,224 mm) e C (0,268 mm). Na combinação gesso II x IV, a menor média de desajuste ocorreu no corte A (0,177 mm), seguida dos cortes B (0,237 mm) e C (0,301 mm), havendo diferença estatística (p<0,05) entre eles. No tempo de pós-prensagem imediato (TO), a menor média de desajuste ocorreu no corte A (0,187 mm), seguida dos cortes B (0,262 mm) e C (0,323 mm), havendo diferença estatística (p<0,05) entre eles. No tempo de pós-prensagem 24 horas (T24) a menor média de desajuste ocorreu no corte A (0,171 mm), com diferença estatística significativa (p<0,05) em relação aos cortes B (0,199 mm) e C (0,246 mm), iguais entre si / Abstract: This study evaluated the complete maxillary denture base adaptation under the effect of the flasking plaster combination (II x III and III x IV types) and post-pressing time (immediate and 24 hours). The bases were made with Clássico heat cured acrylic resin, polymerized in water bath at 74°C for 9 hours. The casts were made with type III plaster stone and the bases made with two wax plates of 0.9 mm. After the bases were processed by the routine technique, the stone cast and the resin bases were fixed with instantaneous adhesive and then transversally sectioned in three zones corresponding to distal of canine (A), mesial of first molars (8), and posterior palatal region (C). The adaptation levei was measured in an Olympus linear comparator microscope, with accuracy of 0.0005 mm. The data were submitted to the ANOVA and Tukey's test (5%). The results showed that there were no statistically significant differences (p<0.05) on the adaptation between the flasking plaster combination II x III (0.224) and IV (0.238 mm). The mean value at the immediate post-pressing time (TO)(0.257 mm) was statistically different from the levels of adaptation at the post-pressing time of 24 hours (T24) (0.205 mm). The best adaptation values were obtained with the flasking plaster combination II x III, when cut A (0.181 mm) was more adapted than cut 8 (0.224 mm) and C (0.268 mm). On the flasking plaster combination II x IV, the best mean value was also obtained in cut A (0.177 mm), followed by 8 (0.262 mm) and C (0.323 mm). All the mean values presented were statistically different for TO and T24. At immediate post pressing time (TO), the highest adaptation was at cut A (0.187 mm), followed by cut 8 (0.262 mm) and C (0.323 mm), with statistical differences (p<0.05). At the post-pressing time of 24 hours (T24), the best adaptation levei was at cut A (0.171 mm) with statistical difference from cut 8 (0.199 mm) and C (0.246 mm) (p<0.05) / Mestrado / Protese Dental / Mestre em Clínica Odontológica
30

Avaliação eletromiografica computadorizada bilateral dos musculos masseter, temporal anterior e digastrico em pacientes reabilitados com proteses totais duplas com variação na dimensão vertical de oclusão

Casselli, Henrique 02 November 2003 (has links)
Orientador: Wilkens Aurelio Buarque e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:38:23Z (GMT). No. of bitstreams: 1 Casselli_Henrique_M.pdf: 16931688 bytes, checksum: 8793dfa78aaad560ffd7399caf228541 (MD5) Previous issue date: 2002 / Resumo: Este estudo teve como objetivo a avaliação eletromiográfica computadorizada bilateral dos músculos masseter e temporal anterior e da musculatura supra-hióidea, antes, durante e após a reabilitação por meio de próteses totais duplas com variação na dimensão vertical de oclusão. Foram selecionados 16 pacientes sem sinais ou sintomas de alterações funcionais do sistema estomatognático, os quais foram submetidos a uma avaliação eletromiográfica inicial e então à utilização de um aparelho intra-oral de cobertura oclusal plana sobre suas próteses usuais, durante 30 dias. Passado esse período foi realizada uma segunda avaliação eletromiográfica e então os pacientes foram reabilitados com próteses novas preservando a existência de um espaço funcional livre de 3mm. Após 60 dias de uso das novas próteses realizou-se a terceira avaliação eletromiográfica e então o espaço funcional livre foi suprimido obtendo-se um aumento da dimensão vertical de oclusão equivalente. As dentaduras assim modificadas foram utilizadas por mais 60 dias, ao término dos quais realizou-se a quarta e última avaliação eletromiográfica. Os dados coletados foram submetidos à análise estatística pelo ANOVA e Teste de Tukey ao nível de significância 5%. Através da análise dos resultados obtidos, pode-se concluir que, para a situação de repouso, houve aumento na atividade elétrica dos músculos masseter e temporal anterior admitindo diferenças estatisticamente significativas entre as avaliações eletromiográficas realizadas com as próteses antigas em relação à segunda avaliação; para a situação de fechamento isométrico houve um significativo aumento da atividade elétrica para os músculos masseteres considerando a primeira avaliação em relação às duas últimas, e uma significativa diminuição da atividade elétrica para os músculos digástricos considerando as duas primeiras avaliações em relação à última / Abstract: The purpose of this study was to evaluate by means of computerized electromyography, the activity of masseter, anterior temporal and digastric bilateral muscles before, during and after total prosthesis rehabilitation with occlusal vertical dimension variation and with the mandible in rest position. Sixteen patients without signs and symptoms of stomatognatic functional disorders were examined, submitted to an initial electromyographic evaluation and then, to an intra-oral plane occlusal splint therapy over the usual prosthesis during thirty days. After this p.eriod a second electomyographic evaluation was performed, and the pacients received new complete dentures with a 3 mm interocclusal rest space for occlusal vertical dimension establishment. After sixty days using the new prosthesis, the third electromyographic evaluation was performed and the interocclusal rest space in occlusal vertical dimension was supressed. The modified prosthesis were used for further sixty days when the forth and last electromyographic analysis was performed. Data were submitted to ANOVA and Tukey Test at the 5% confidence leveI. Results showed a significant increase in the electromyographic activity for the anterior temporal and masseter muscles between the initial and second evaluation periods in the rest position. For the closing with no resistance situation, masseter muscles showed a significant increase in the electrical activity at the third and last periods of evaluation, while for the digastric muscles, a decrease in the electrical activity between the initial period and the last one was verified. / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.0406 seconds