• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 710
  • 37
  • 37
  • 37
  • 37
  • 28
  • 9
  • 8
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 728
  • 728
  • 357
  • 269
  • 232
  • 185
  • 141
  • 141
  • 123
  • 118
  • 107
  • 105
  • 89
  • 80
  • 77
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Análise e comparação da interface implante/pilar de pilares de zircônia usinados por tecnologia CAD/CAM sobre implantes HE.

Rodríguez Ivich, Elí Jair January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia, Florianópolis, 2016 / Made available in DSpace on 2016-09-20T04:45:20Z (GMT). No. of bitstreams: 1 340525.pdf: 1688167 bytes, checksum: 70875b398c49ad9d4d9b2835008966ec (MD5) Previous issue date: 2016 / O objetivo deste estudo foi determinar a precisão marginal de diferentes pilares de zircônia usinados por sistemas de CAD/CAM instalados sobre implantes Hexágono Externo. Foram utilizados doze implantes de hexágono externo Easy Grip (Conexão Sistema de Prótese Ltda) de 10mm de comprimento e 4.0 mm de diâmetro. Foram utilizados quatro tipos de pilares: Grupo 1 Pilares de titânio pré-fabricados (30 N); Grupo 2 Pilares de zircônia: Dental Wings (20 N); Grupo 3 Pilares de zircônia: 3Shape (20 N); Grupo 4 Pilares Ti-base: (CEREC, Sirona) (35 N). As amostras foram apreendidas em um porta-amostra e segmentadas ao longo eixo. A espessura da interface implante-pilar foi mensurada por microscopia óptica em 6 diferentes pontos. Os valores da análise de variância resultaram que os tamanhos da interface do grupo 1 (Ti) foram significativamente menores do que os observados nos pilares ceâmicos (P <0,05). Os valores da interface do grupo 1 (Ti) não foram significativamente diferentes aos valores do grupo 4 (P>0.05). No entanto, foi encontrada uma diferença significativa entre as interfaces dos pilares de titânio (grupo 1 e 4) em comparação com os pilares de zircônia (grupo 2 e 3). Dentro dos limites deste estudo, mostrou-se que os pilares de zircônia não podem ser usinados com o mesmo grau de precisão que os pilares metálicos. As consequências mecânicas e o risco de infiltração microbiana da interface implante-pilares de zircônia devem ser avaliados em investigações clínicas. <br> / Abstract : The aim of this study was to determine the marginal accuracy of different zirconia abutments machined by CAD/CAM systems screwed on external hexagon implants. Twelve external hexagon (HE) ( Easy Grip, Prosthesis System Connection Ltd.) implants (10mm long and 4.0 mm) were used. Four types of abutments were used: Group 1 - prefabricated titanium abutments (30 N); Group 2 - zirconia abutments: Dental Wings (20 N); Group 3 - zirconia abutments: Tree Shape (20 N); Group 4 - Ti-base abutmetns: CEREC (35 N). The samples were placed in a sample port and segmented through the long axis. The thickness of the implant-abutment interface was measured by optical microscopy in 6 different points. One-way ANOVA have shown that the interfacial gaps from group 1 (Ti) were significantly lower than those observed in zirconia abutments (P <0.05), but were not significantly different from the values of Group 4 (P> 0.05). However, a significant difference was found between the interfaces of titanium abutments (Groups 1 and 4) compared with the zirconia abutments (Groups 2 and 3). Within the limits of this study showed that the zirconia abutments can not be machined with the same degree of precision as the metal abutments. The mechanical effects and the risk of microbial infiltration of zirconia implant-abutment interface should be evaluated in clinical research.
52

Avaliação, por extensometria, da deformação superficial no substrato de retenção dos implantes gerada por próteses fixas implanto suportadas em função do cantilever

Mesquita, Alfredo Mikail Melo [UNESP] 30 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-30Bitstream added on 2014-06-13T18:45:59Z : No. of bitstreams: 1 mesquita_amm_dr_sjc.pdf: 511472 bytes, checksum: bdcad35472f1cab510c82684030d9a0f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar, por extensometria, da deformação superficial ao redor de implantes em função do comprimento do cantilever de próteses implanto-suportadas por 2 ou 3 implantes. Para tanto, foram posicionados, paralelos entre si, implantes auto-rosqueáveis de hexágono externo, com dimensões de 3,75mm de diâmetro por 11,5mm de comprimento, a uma distância entre eles de 8mm, de centro a centro, em um modelo experimental de poliuretano com dimensões de 10x7x2cm. Pilares protéticos tipo Multi-Unit, com 3,0mm de altura de cinta metálica foram instalados sobre os implantes. Com auxílio de um dispositivo em alumínio, foram confeccionados 16 padrões de fundição em resina acrílica; 8 com 2 implantes; e 8 com 3 implantes sobre cilindros calcináveis. Em seguida os padrões foram fundidos em liga de cobaltocromo pela técnica convencional à maçarico. Três extensômetros lineares (strain gauges) foram colados na superfície superior do bloco experimental de poliuretano tangenciando a plataforma dos implantes. Cargas de 10kg foram exercidas na barra em local eqüidistante entre os dois implantes mais próximos do cantilever, e no cantilever a uma distância de 5, 10, 15, 20 e 25mm, com auxílio de um dispositivo desenvolvido para esta finalidade. Os extensômetros conectados a um aparelho condicionador de sinais elétricos além de alimentar a corrente elétrica, amplificou e converteu o sinal gerado de analógico para digital. Para cada local de carga foram feitas três medições. Os dados obtidos foram submetidos à Análise de Variância (ANOVA) de 3 fatores, e ao teste de Tukey (p<0,05). Como conclusão do tratamento dos dados obtidos em microdeformação (με): não houve diferença da utilização de dois ou três implantes na distribuição de carga no substrato de retenção dos implantes; quanto maior a extensão do cantilever, maiores deformações foram geradas ao redor dos implantes. / The aim of this study was to evaluate, using strain gauge, the load distribution surround the implants according the cantilever length of implant-supported prosthesis by two or three implants. Sixteen polyurethane models were obtained from an acrylic block (10 x 7 x 2 cm). In half of these models two cylindrical implants with external hexagon were fixed (diameter: 3.75 mm; length: 11.5 mm) and positioned 8 mm between their centers in each model. On the other half, three parallels implants were fixed in the same conditions. The Multi-Unit abutments with 3 mm of metallic neck were connected to the implants. With the assistance of an aluminum device, it was manufacture sixteen acrylic resin patterns over the cast cylinders: eight with two implant and eight three implants. After, patterns were casted in cobalt-chromium alloy, using the casting conventional technique. Three strain gauges were positioned on the upper surface of the experimental polyurethane model around the implants. With an assistance of a device, the metallic bars were loaded with 10 Kg between the two implants near to the cantilever and 5, 10, 15, 2 and 25 mm along the cantilever length. The strain-gauge was connected to a multichannel bridge amplifier to form one leg of the bridge. The computer was interfaced with bridge amplifier to register output signs of polyurethane strain. Each point of loading was measured three times. The data were submitted to ANOVA (three-way) and Tukey test (p<0.05). The cantilever length affected negatively the load distribution around the implants around the implants (p<0.05). Such as conclusion t from the treatment of the data obtained (με): there wasn’t difference between the using of two or three implants on the stress distribution on the substrate of implants retention; how longer is the cantilever, higher stress around implants were generated.
53

Taxa de sobrevida, carga para fratura e análise por elementos finitos de dentes anteriores restaurados com facetas cerâmicas variando o desenho do preparo

Bergoli, César Dalmolin [UNESP] 01 August 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-08-01Bitstream added on 2014-06-13T20:06:13Z : No. of bitstreams: 1 000757600.pdf: 2238658 bytes, checksum: e4af2fec93f2c954b6aa895e20cc674a (MD5) / O objetivo deste estudo foi avaliar a taxa de sobrevida, carga para fratura e distribuição de tensões de incisivos centrais e caninos superiores restaurados com facetas cerâmicas variando o desenho do preparo. Trinta incisivos centrais superiores e trinta caninos superiores (N=60) foram selecionados para o estudo. Os espécimes foram embutidos até 3 mm da junção cemento esmalte e o ligamento periodontal simulado usando um material a base de poliéter. Após essa etapa os espécimes foram randomizados em quatro grupos (n=15) de acordo com o desenho do preparo e o tipo de dente: Gr1- Incisivo central com preparo conservador; Gr2- Incisivo central com preparo convencional com chanfro palatino; Gr3- Canino com preparo conservador; Gr4 – Canino com preparo convencional com chanfro palatino. Os espécimes foram restaurados com facetas cerâmicas a base de di-silicato de lítio, obtidas pela técnica da injeção. Os espécimes foram submetidos à 4.106 ciclos mecânicos (45º, 37oC, 100 N, 4 Hz) e avaliados quanto a possíveis falhas a intervalos de 500.000 ciclos. Ao final da ciclagem mecânica os espécimes que sobreviveram foram submetidos ao teste de compressão. Modelos semelhantes aos utilizados no teste laboratorial foram simulados bi-dimensionalmente (Rhinoceros® 4.0) e o comportamento mecânico avaliado (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) através dos valores de Tensão Máxima Principal. As taxas de sobrevida dos corpos de prova foram calculadas pelo teste de Kaplan Meier e Log-rank (α=0.05) e os valores de carga para fratura pelo teste T-Student (α=0.05). Todos os grupos apresentaram taxas de 100 % de sobrevida, não havendo diferença estatística entre eles. O teste T-Student não mostrou diferença estatística para os diferentes desenhos de preparo, mas mostrou diferença para os diferentes dentes submetidos ao mesmo desenho de preparo. O teste de elementos finitos... / The aim of this study was to evaluate the survival rate, load to fracture and tensile distribution of human central incisors and canines restored with ceramic veneers varying the prepare design. Thirty human central incisors and thirty canines (N=60) were selected for the study. The specimens were embedded with acrylic resin up to 3 mm of the cemento/enamel junction and the periodontal ligament was simulated with polyether. After this step the specimens were randomized in four groups (n=15), based on the tooth prepare design and type of teeth: Gr1- Central incisor with a conservative prepare; Gr2- Central incisor with conventional prepare with palatine chamfer; Gr3- Canine with conventional prepare; Gr4 - Canine with conventional prepare with palatal chamfer. The specimens were prepared, molded and models with rock stone type IV were obtained. Ceramic veneers (IPS e.max Press, Ivoclar Vivadent, Schann) were confectioned. The veneers were adhesively cemented on specimens. The specimens were submitted to mechanical cycling (45o, 37oC, 100 N, 4 Hz, 4.000.000 cycles) and evaluated at each 500.000 cycles to detect any kind of failure. Specimens that survive to mechanical cycling were submitted to fracture resistance test. Identical models were draw bi-dimensionally (Rhinoceros® 4.0) and the mechanical behavior were evaluated (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) by Maximum Principal Stress. The survival rate were evaluated by Kaplan-Meier test (α=0.05), while load to fracture values was evaluated by T-Student test (α=0.05). All groups showed same values of survival rate (100%). Same teeth showed same values of fracture load, independently the design of prepare. Different teeth, showed differences in the fracture load, when submitted to same design prepare. The laminate veneer with the palatal chamfer design showed higher Maximum Principal Stress values
54

Efeito da terapia cirúrgica anti-infecciosa sobre biomarcadores imunológicos em pacientes portadores de peri-implantite

Zani, Sabrina Rebollo January 2015 (has links)
Made available in DSpace on 2015-06-16T02:06:48Z (GMT). No. of bitstreams: 1 000470529-Texto+Completo-0.pdf: 1858726 bytes, checksum: 5770182d321cd5a1e49c65dc3d839f41 (MD5) Previous issue date: 2015 / The objective of the present study was to evaluate the effects of an antiinfective surgical therapy over 20 peri-implant crevicular fluid biomarkers in patients with peri-implantitis and to compare these immunologic profiles with the clinical parameters. Fifty-two patients presenting implants affected by peri-implantitis were classified into 4 groups according with probing depth and the presence of bleeding and/or suppuration at mesio-buccal site of each implant with periimplantitis. Clinical parameters were measured and PICF samples were collected from the mesio-buccal site of every implant. All subjects were submitted to anti-infective surgical therapy. Clinical parameters and PICF biomarkers were re-measured at 6 and 12 months after treatment. PICF samples were analyzed using multiplex bead immunoassay for 20 biomarkers. Differences over time were analyzed using generalized estimating equations. The significance level established for all analyses was 5% (p <0. 05).The results demonstrated a significant reduction of the clinical parameters post-therapy. However, it was observed a significant increase of some pro-inflammatory biomarkers levels (IL-1β, IL-6, IL-12p40, IL-12p70, IL-17a e sCD-40L). And IL-13 was the only anti-inflammatory cytokine, which had a significant increase in its levels after anti-infective surgical therapy. / O presente estudo tem por objetivo avaliar o efeito da terapia cirúrgica anti-infecciosa sobre 20 biomarcadores imunológicos em pacientes com periimplantite, e comparar esse perfil imunológico com os parâmetros clínicos. Foram selecionados 52 pacientes que apresentavam implantes com peri-implantite, os quais foram divididos em 4 grupos de acordo com a profundidade de sondagem e presença de sangramento e/ou supuração no sítio mésio-vestibular de cada implante com peri-implantite. Os parâmetros clínicos foram mensurados e amostras de fluido crevicular peri-implantar, coletadas do sítio mésio-vestibular de cada implante. Todos pacientes foram submetidos à terapia cirúrgica anti-infecciosa e reavaliados 6 e 12 meses após o tratamento. As amostras de fluido crevicular foram analisadas através do ensaio imunológico Luminex (multi-análise com micro-esferas) para detecção de 20 biomarcadores. Diferenças entre os grupos em relação aos níveis desses biomarcadores ao longo do tempo foram analisadas estatisticamente através das equações de estimação generalizadas. O nível de significância estabelecido foi de 5% (p < 0,05).Os resultados demonstraram reduções significativas dos parâmetros clínicos, entretanto mostraram aumentos significativos dos níveis de alguns biomarcadores pró-inflamatórios (IL-1β, IL-6, IL-12p40, IL-12p70, IL-17a e sCD-40L) após a terapia cirúrgica. A IL-13 foi a única citocina anti-inflamatória que mostrou aumento significativo após o tratamento.
55

Taxa de sobrevida, carga para fratura e análise por elementos finitos de dentes anteriores restaurados com facetas cerâmicas variando o desenho do preparo /

Bergoli, César Dalmolin. January 2013 (has links)
Orientador: Marco Antonio Bottino / Co-orientador : Josete Barbosa Cruz Meira / Co-orientador : Luiz Felipe Valandro Soares / Banca: Renata Marques de Melo Marinho / Banca: Alexandre Luiz Souto Borges / Banca: Renata Faria / Banca: Carlos José Soares / Resumo: O objetivo deste estudo foi avaliar a taxa de sobrevida, carga para fratura e distribuição de tensões de incisivos centrais e caninos superiores restaurados com facetas cerâmicas variando o desenho do preparo. Trinta incisivos centrais superiores e trinta caninos superiores (N=60) foram selecionados para o estudo. Os espécimes foram embutidos até 3 mm da junção cemento esmalte e o ligamento periodontal simulado usando um material a base de poliéter. Após essa etapa os espécimes foram randomizados em quatro grupos (n=15) de acordo com o desenho do preparo e o tipo de dente: Gr1- Incisivo central com preparo conservador; Gr2- Incisivo central com preparo convencional com chanfro palatino; Gr3- Canino com preparo conservador; Gr4 - Canino com preparo convencional com chanfro palatino. Os espécimes foram restaurados com facetas cerâmicas a base de di-silicato de lítio, obtidas pela técnica da injeção. Os espécimes foram submetidos à 4.106 ciclos mecânicos (45º, 37oC, 100 N, 4 Hz) e avaliados quanto a possíveis falhas a intervalos de 500.000 ciclos. Ao final da ciclagem mecânica os espécimes que sobreviveram foram submetidos ao teste de compressão. Modelos semelhantes aos utilizados no teste laboratorial foram simulados bi-dimensionalmente (Rhinoceros® 4.0) e o comportamento mecânico avaliado (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) através dos valores de Tensão Máxima Principal. As taxas de sobrevida dos corpos de prova foram calculadas pelo teste de Kaplan Meier e Log-rank (α=0.05) e os valores de carga para fratura pelo teste T-Student (α=0.05). Todos os grupos apresentaram taxas de 100 % de sobrevida, não havendo diferença estatística entre eles. O teste T-Student não mostrou diferença estatística para os diferentes desenhos de preparo, mas mostrou diferença para os diferentes dentes submetidos ao mesmo desenho de preparo. O teste de elementos finitos... / Abstract: The aim of this study was to evaluate the survival rate, load to fracture and tensile distribution of human central incisors and canines restored with ceramic veneers varying the prepare design. Thirty human central incisors and thirty canines (N=60) were selected for the study. The specimens were embedded with acrylic resin up to 3 mm of the cemento/enamel junction and the periodontal ligament was simulated with polyether. After this step the specimens were randomized in four groups (n=15), based on the tooth prepare design and type of teeth: Gr1- Central incisor with a conservative prepare; Gr2- Central incisor with conventional prepare with palatine chamfer; Gr3- Canine with conventional prepare; Gr4 - Canine with conventional prepare with palatal chamfer. The specimens were prepared, molded and models with rock stone type IV were obtained. Ceramic veneers (IPS e.max Press, Ivoclar Vivadent, Schann) were confectioned. The veneers were adhesively cemented on specimens. The specimens were submitted to mechanical cycling (45o, 37oC, 100 N, 4 Hz, 4.000.000 cycles) and evaluated at each 500.000 cycles to detect any kind of failure. Specimens that survive to mechanical cycling were submitted to fracture resistance test. Identical models were draw bi-dimensionally (Rhinoceros® 4.0) and the mechanical behavior were evaluated (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) by Maximum Principal Stress. The survival rate were evaluated by Kaplan-Meier test (α=0.05), while load to fracture values was evaluated by T-Student test (α=0.05). All groups showed same values of survival rate (100%). Same teeth showed same values of fracture load, independently the design of prepare. Different teeth, showed differences in the fracture load, when submitted to same design prepare. The laminate veneer with the palatal chamfer design showed higher Maximum Principal Stress values / Doutor
56

Estudo das microdeformações geradas ao redor de implantes de hexágono interno com roscas convencionais e implantes com platôs, sob a aplicação de carga vertical /

Santos, Vivian Mayumi Miyazaki. January 2013 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Eduardo Shigueyuki Uemura / Banca: Luis Gustavo de Oliveira Vasconcellos / Resumo: O objetivo deste estudo foi avaliar a micro deformação ao redor de implantes hexágono interno e implantes com roscas platô sob carregamento vertical. Foram confeccionados 10 blocos de poliuretano com 190X30X12 mm. Na face de menor largura e maior comprimento de cada bloco foi inserido um implante de cada sistema (implante hexágono interno de 4 mm X 8,5 mm e implante platô de 4,5 mm X 8 mm) que depois receberam um pilar com 10 mm de altura. O pilar do implante hexágono interno recebeu torque de 20 N com auxilio de torquímetro manual, enquanto o pilar do implante platô foi inserido no implante com o auxilio de martelete. Quatro extensômetros foram colados ao redor dos implantes. Também foram colados extensômetros na lateral do bloco na região do terço médio e apical dos implantes. Os implantes foram submetidos a uma carga vertical estática de 30 Kg. Os dados foram submetidos a análise estatística ANOVA e Tukey (5%). Foi verificado que houve diferença estatística significante para a região cervical (horizontal) dos implantes em relação à região média e apical (vertical), sendo o P=0.0259. Com o teste Tukey, foi verificado que a região horizontal dos implantes platôs apresentaram uma maior micro deformação em relação a região vertical e da região horizontal e vertical dos implantes hexágono interno. Pode-se concluir que o implante platô demonstrou maior micro deformação do que o implante hexágono interno, a região cervical obteve uma maior concentração de tensões em relação à região do terço médio e apical e que o tipo de conexão pilar/implante interfere na micro deformação distribuída ao redor do implante / Abstract: The aim of the study was to evaluate the micro strain around internal hexagon implant and plateau screws implant under vertical load. 10 polyurethane blocks were produce with 190X30X12 mm. On the narrower face of each block was inserted in each system implant (internal hexagon implant 4 mm X 8,5 mm and plateau implant 4,5 mm X 8 mm) which then received one abutment with 10 mm high. The internal hexagon abutment received torque of 20 N with aid manual torquemeter and plateau abutment was inserted with surgical mallet. Four strain gauge were bonded around of the implants. Also the strain gauges were bonded in the lateral block in the middle and apical region implants. The implants were subjected to a static vertical load of 30 kg. The data were submitted to ANOVA and Tukey (5%). It was found that there was statistically significant difference for the cervical region (horizontal) of the implants to the middle and apical region (vertical), with P = 0.0259. In the Tukey test, it was found that the horizontal region of the plateau implants was higher micro strain than vertical region of the plateau implants and horizontal and vertical region of the internal hexagon implants. It concluded that the implant had a higher plateau micro strain of the implant internal hexagon, the cervical region showed a higher stress concentration towards the region of the middle and apical, and the connection type abutment/implant interferes with micro strain distributed around the implant / Mestre
57

Estomatite protética em pacientes com Diabetes mellitus : prevalência de Candida spp. e eficiência dos tratamentos com nistatina e desinfecção de próteses por micro-ondas /

Sanitá, Paula Volpato. January 2011 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Marco Antonio Compagnoni / Banca: Silvana Regina Perez Orrico / Banca: Helena de Freitas Oliveira Paranhos / Banca: Karin Hermana Neppelenbroek / Resumo: Este estudo in vivo teve como objetivos avaliar: 1. a prevalência das diferentes espécies de Candida em pacientes diabéticos portadores de estomatite protética e compará-la àquela de pacientes não diabéticos com/sem estomatite protética; 2. a eficiência de dois tratamentos para estomatite protética em pacientes diabéticos: terapia antifúngica com nistatina e desinfecção de próteses totais por micro-ondas. Para isso, 210 pacientes usuários de prótese totais foram selecionados e distribuídos em três grupos de estudo. O grupo controle - GC foi formado por 90 pacientes não diabéticos e com mucosa oral saudável; os grupos experimentais foram formados por portadores de estomatite protética, sendo 80 pacientes não diabéticos - EPND e 40 diabéticos do tipo 2 controlados - EPD. Uma avaliação intra-oral dos pacientes dos grupos experimentais foi realizada e a aparência clínica da mucosa inflamada foi classificada de acordo com os critérios de Newton em graus I, II ou III. Coletas microbiológicas das próteses totais foram realizadas com swab estéril e plaqueadas em meio CHROMagar Candida. Em seguida, os procedimentos de identificação foram realizados: análise de microcultivo, teste de triagem fenotípica em caldo hipertônico e testes bioquímicos (ID-32C). Os resultados obtidos foram analisados por Intervalo de Confiança de Bonferroni e testes Exato de Fisher e Qui Quadrado (α=0,05). Os 40 pacientes diabéticos foram, então, submetidos ao tratamento da estomatite protética. Para isso, foram aleatoriamente distribuídos em 2 grupos (n=20): grupo NIS - tratamento com antifúngico tópico nistatina (suspensão oral - 100.000UI/mL), 4 vezes ao dia, por 14 dias; grupo MIC - tratamento por meio da irradiação das totais por micro-ondas (650W / 3 minutos), 3 vezes por semana, por 14 dias. Dois parâmetros... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this in vivo study was to evaluate: 1. the prevalence of Candida spp. in well-controlled type 2 diabetic patients and compare it to that found in non-diabetics with/without denture stomatitis; 2. the efficacy of two treatments of denture stomatitis in diabetic patients: topical nystatin and denture microwave disinfection. Two hundred and ten denture wearer patients were divided into three groups of study. The control group - CG was formed by 90 individuals without diabetes or denture stomatitis and the experimental groups were formed by patients with denture stomatitis, being 80 non-diabetics - DSND and 40 well-controlled type 2 diabetics - DSD. Mucosal characteristics of denture stomatitis patients were classified in types I, II, and III, according to Newton's criteria. Mycological samples were taken from the dentures and cultured in CHROMagar′s plates. Candida spp. were identified by micro-cultivation, hypertonic Sabouraud broth, and bioMérieux ID32C assays. Results were analyzed by means of Bonferroni corrected confidence interval, Fisher's exact test, and Chi-square analysis of several proportions (α=0.05). The 40 diabetic patients were divided into two groups (n=20) and submitted to two treatments for denture stomatitis: NYS group - patients were treated with topical nystatin, 4 times a day, for 14 days; MW group - patients had their dentures microwaved (650W / 3 minutes), 3 times per week, for 14 days. Mycological samples were taken from the palates and the tissue surface of the dentures for quantification and identification of Candida spp. and standardized photographs of the palates were taken for the clinical analysis. Microbiological and clinical evaluations were repeated at baseline... (Complete abstract click electronic access below) / Doutor
58

Estudo prospectivo de falhas biomecânicas em próteses totais fixas implantossuportadas: série de casos

Petri, Luciano Costa January 2013 (has links)
Made available in DSpace on 2014-01-23T01:01:18Z (GMT). No. of bitstreams: 1 000453302-Texto+Completo-0.pdf: 2301270 bytes, checksum: cbc68a0ea07f8954655bd0c9592bed33 (MD5) Previous issue date: 2013 / Complications and failures in implant supported fixed dentures (ISFD) can be related to several biological and mechanical factors, such as maximum bite force (MBF), design of the infrastructure, thickness of the aesthetic coating over metal framework and nocturnal bruxism. The aim of this case series study was to describe the failures of ISFD regarding the characteristics of aesthetic coating thickness, bite force and the presence of nocturnal bruxism. Seventeen patients who received ISFD were followed over a period of 6 to 12 months. Data were collected through anamnesis questionnaires, clinical examinations, MBF measurements and recording of the distribution of occlusal forces on the dental arch during centric and eccentric movements (protrusion and laterotrusion). The presence of bruxism was assessed by questionnaires, clinical examination and BiteStrip® device. Complications were observed in 4 patients, of which three individuals had avulsion of an artificial denture tooth while a small tooth fracture was located adjacent to the screw access hole in the other case. The findings suggest that failures caused by artificial tooth avulsion may have occurred mainly due to lack of internal retention provided by metal extensions of infrastructure. The fracture adjacent to the screw access hole was probably due to excessive opening on the resin tooth. Further studies with larger sample size and longer clinical follow-up are necessary to determine the possible risk factors for biomechanical failure of ISFD due to occlusal overload and / or design of the infrastructure. / Complicações e falhas em próteses totais fixas implantossuportas (PTFI) podem estar relacionadas a fatores biológicos e mecânicos, tais como força máxima de mordida (FMM), desenho da infraestrutura metálica, espessura do revestimento estético e presença de bruxismo noturno. O objetivo deste estudo de série de casos foi descrever as falhas das PTFI em relação às características de espessura do revestimento estético, da força de mordida e da presença de bruxismo noturno. Foram acompanhados 17 pacientes que receberam PTFI durante um período de 6 a 12 meses. Os dados foram coletados através de exame físico, anamnese, medição de FMM e registro da distribuição de forças oclusais na arcada dentária em posições cêntrica e excêntricas (protrusão e lateralidades). A presença de bruxismo foi avaliada através de questionário, exame clínico e dispositivo BiteStrip®. Como resultado, foram observadas complicações em 4 pacientes, dos quais três indivíduos tiveram avulsão do dente da prótese e outro uma pequena fratura localizada adjacente ao orifício de acesso do parafuso em uma face dentária. Os achados sugerem que as falhas de avulsão de dente artificial podem ter ocorrido principalmente devido a falta de retenção interna proporcionada por pino da infraestrutura metálica. Já a fratura adjacente ao orifício de acesso do parafuso provavelmente ocorreu devido a uma excessiva abertura na resina do dente. Há necessidade de estudos subsequentes com ampliação da amostra e maior tempo de acompanhamento clínico para determinar os possíveis fatores de risco para falhas biomecânicas de PTFIs devido à sobrecarga oclusal e/ou desenho da infraestrutura.
59

Citoxicidade dos materiais protéticos dentários utilizados em implantodontia: estudo in vitro

Maia, Camila Francine January 2014 (has links)
Made available in DSpace on 2014-05-22T02:00:45Z (GMT). No. of bitstreams: 1 000458171-Texto+Completo-0.pdf: 387216 bytes, checksum: 93ef6b7911900fc5bf72d886ca1057ec (MD5) Previous issue date: 2014 / The choice of material used in the manufacture of dental prostheses on implants can be directly linked to the quality and maintenance of gingival tissue. The aim of this study was to evaluate the cytotoxicity of dental prosthetic materials in fibroblasts in cell culture by MTT assay at 24, 48, 72 h. Samples of materials were prepared: Titanium (Ti), polietereter-ketone (PEEK), composite resin (CR) and acrylic resin (AR) and left in contact with D-MEM for 24 h. NIH/3T3 cells was seeded in 96-well plate and added to the medium that were in contact with the test material. Wells containings only cells were used for negative control (NC) for toxicity. For positive control (PC) for toxicity cells were subjected to the action of sodium hypochlorite. The results were subjeted to calculating the percentage of cell viability and to statistical one-way anlysis of variance (ANOVA) followed by Tukey test (p <0. 05). The results of percentage cell viability at 24 h were CN 100%, Ti 67. 52%, 65. 71% PEEK, RC 44. 49%, RA 49. 09%, CP 4. 29%. Conclusion: The Ti and PEEK demonstrated a similar trend in our research, as well as the RC and RA. The worst results were observed for RC at all times observed. / A escolha do material utilizado na confecção das próteses dentárias sobre implantes podem ter ligação direta com a qualidade e manutenção de tecido gengival. O objetivo deste trabalho foi avaliar a citotoxicidade de materiais protéticos dentários em cultura de fibroblastos através do teste MTT em intervalos de tempo de 24, 48 e 72 h. Foram confeccionadas amostras dos seguintes materiais: titânio (Ti), polietereter-cetona (PEEK), resina composta fotopolimerizável (RC) e resina acrílica autopolimerizável (RA), que foram deixados em eluição no meio de cultura D-MEM durante 24 h. Células NIH/3T3 foram semeadas em placas de 96 poços, seguido da adição do meio de cultura que esteve em contato com os materiais em teste. Para controle negativo de citoxicidade (CN), foram utilizados poços contendo somente células e meio de cultura. Para o controle positivo de citoxicidade (CP) as células foram submetidas à ação de hipoclorito de sódio. Os resultados foram submetidos ao cálculo de percentagem de viabilidade celular ao teste estatístico de análise de variância (ANOVA) seguido do teste de Tukey (p<0,05). Os resultados de percentagem de viabilidade celular em 24 h foram: CN 100%, Ti 67,52%, PEEK 65,71%, RC 44,49%, RA 49,09%, CP 4,29%. Conclusão: O Ti e o PEEK demostraram uma evolução semelhante na nossa pesquisa, bem como a RC e a RA, sendo os piores resultados observados foram para RC em todos os tempos observados.
60

Distribuição de tensões em overdentures suportadas por implantes cônicos e cilíndricos: análise por elemento finito tridimensional

Sartori, Evandro Afonso January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:13Z (GMT). No. of bitstreams: 2 000399519-0.pdf: 2442576 bytes, checksum: 55b6e477b1bfaae44cca2d6ca7629555 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study using 3D-finite element analysis compared the stress distribution generated by a static load on implant-supported overdenture as a function of implant geometry (cylindrical versus conical shape). Tridimensional models were built from the images of a computerized tomography of a mandible and 3D laser digitalization of implants, abutments, mucosa, and complete denture. The geometric models of implants and abutments were mounted at the canine region (teeth 43 and 33) to build two models: model 1 – overdenture supported by two cylindrical implants, and model 2 – overdenture supported by two conical implants. The geometric models were converted into finite element models using a commercial software. A 100 N load simulating a masticatory bolus was applied at the first molar region of each model. The von Mises stress distribution was analyzed and compared in selected points. The stresses in both cylindrical and conical implants were similar and concentrated at the cervical and middle thirds. The implants placed at the loading side showed larger area of stress than the contralateral implants, but the stress magnitude was similar. In relation to the mandibular bone, the anterior surface had larger stress concentration at the distal area of both types of implants on the loading side than that of the contralateral side. The stress magnitude on the bone surface was similar but the area of higher stress distribution was larger for the cylindrical implant at the loading side. In a longitudinal section of the bone at the tooth 43 site, the higher stresses were concentrated at the cervical region of both implant shapes corresponding to the cortical bone. In relation to the bone at the tooth 33 region, the stresses were higher at the mesial side of the cylindrical implant compared to the conical implant. Therefore, the results suggest that conical implants provided reduction of the area of von Mises stress in the mandibular bone at the loading side. At the contralateral side the von Mises stress was similar for both implants. / Este trabalho teve por objetivo comparar a distribuição de tensões geradas por uma carga estática vertical aplicada em prótese do tipo overdenture implanto - muco -suportadas, retida por implantes cilíndricos ou cônicos, através de análise por elementos finitos. Foram gerados modelos tridimensionais de uma mandíbula edêntula a partir das imagens de tomografia computadorizada helicoidal e dos intermediários protéticos, da prótese total, da placa resiliente e dos implantes através de digitalização a laser em três planos. Os modelos geométricos dos implantes e intermediários protéticos foram montados na região dos caninos (dentes 43 e 33) no modelo mandibular, constituindo dois modelos: modelo 1 – overdenture retida por dois implantes cilíndricos e modelo 2 – overdenture retida por dois implantes cônicos. Os modelos geométricos foram inseridos em um software, no qual foi gerada a malha de elementos finitos. Uma carga vertical estática de 100 N foi aplicada indiretamente, sobre uma simulação de bolo alimentar, na região de primeiro molar inferior direito, sendo analisadas e comparadas as tensões pelo método de von Mises geradas nos dois modelos. As tensões foram semelhantes nos implantes cilíndrico e cônico, com concentração nos terços cervical e médio. Os implantes inseridos na região do dente 43, lado da aplicação da carga, apresentaram maior área de tensões que os implantes contralaterais na região do dente 33, embora a magnitude das tensões tenha sido similar. Em relação ao osso mandibular, na parte externa anterior houve maior concentração de tensões na área distal dos dois tipos de implante inseridos no lado de aplicação da carga em comparação com os implantes contralaterais.A magnitude das tensões no osso foi semelhante para ambos os tipos de implante, mas a área de distribuição das maiores tensões foi maior para o implante cilíndrico na região do dente 43. Em um corte longitudinal do osso mandibular na região dos implantes 43, observaram-se as maiores tensões concentraram-se na região cervical de ambos os tipos de implante, no osso cortical. Já em relação ao osso mandibular na região do dente 33, observou-se que as tensões foram maiores na face mesial do implante cilíndrico em relação ao implante cônico. Assim, os resultados deste estudo sugerem que os implantes cônicos promoveram redução da área de maiores tensões de von Mises no osso mandibular no lado da aplicação da carga. Quanto ao lado contralateral as tensões foram similares em ambos os implantes

Page generated in 0.0438 seconds