• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 8
  • 8
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Padronização do volume pulmonar pela tomografia

Basso, Caio Ferraz January 2019 (has links)
Orientador: Sergio Marrone Ribeiro / Resumo: A medida correta e acurada do volume pulmonar é uma importante ferramenta de avaliação diagnóstica e terapêutica na prática clínica. Atualmente, com o avanço da capacidade de reconstrução tridimensional da Tomografia Computadorizada (TC) é possível mensurar o volume pulmonar total por este aparelho. O presenta trabalho busca apresentar uma nova técnica de mensuração do volume pulmonar e estabelecer uma padronização de valores normais do volume pulmonar na população adulta. O volume pulmonar total de 95 pacientes, assim como quatro medidas antropométricas obtidas na TC foram analisados. Em um intervalo de confiança de 95%, se estabeleceu os limites inferiores e superiores da relação entre o volume e cada uma das medidas, assim valores de importância estatística. / Abstract: Correct and accurate measurement of lung volume is an important diagnostic and therapeutic evaluation tool in clinical practice. Nowadays, with the advancement of the capacity of three-dimensional reconstruction of Computed Tomography (CT), it is possible to measure the total lung volume by this device. The present paper aims to present a new technique for measuring lung volume and establish a standardization of normal values of lung volume in the adult population. The total lung volume of 95 patients, as well as four anthropometric measurements obtained at CT were analyzed. In a 95% confidence interval, we established the lower and upper limits of the relationship between the volume and each of the measures, thus values of statistical importance. / Mestre
2

Validação do sistema de gerenciamento de banco de dados da Coleção de Culturas de Fungos de Referência do INCQS/FIOCRUZ / Validation of the database management system of the Reference Fungi Culture Collection of INCQS/Fiocruz

Fialho, Miguel Madi January 2010 (has links)
Made available in DSpace on 2012-05-07T15:02:17Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 000012.pdf: 9383091 bytes, checksum: 88e7a35810c189cbcb0ebde99c5d4e73 (MD5) Previous issue date: 2010 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. / A validação para adequação dos itens de qualidade é uma orientação do Guia Para Operação de Centros de Recursos Biológicos da OCDE (Organização para Cooperação e Desenvolvimento Econômico). Os Centros de Recursos Biológicos (CRB) devem disponibilizar dados descrevendo o material biológico e sua origem ao Global Biological Resource Centre Network (GBRCN). De acordo com o guia, os CRBs deverão produzir e armazenar dados eletrônicos e catálogos baseados em informações validadas. Os dados também devem ser conservados para rastreabilidade em conformidade com as leis, regulamentos e políticas nacionais. Os depositários são responsáveis por assegurar a qualidade dos dados associados com o material biológico. A orientação da norma da qualidade ABNT NBR ISO/IEC 17025:2005, é que softwares de prateleira utilizados devam ser validados. Utilizando as ISOs para qualidade de produção de software de prateleira, engenharia de software, visão geral e processos, processos de ciclo de vida de software, incluindo a comprovação documental, este trabalho resultou na validação do Sistema de Gerenciamento de Banco de Dados INFOGER_FUNGOS, uma ferramenta de administração da Coleção de Micro-organismos de Referência avaliando sua capacidade de desempenho e qualidade. Este sistema é objeto de um processo de propriedade intelectual para tratamento de dados, gerando informações de qualidade nos serviços de referência desta Coleção. / Validation for adequacy of quality items is an orientation of the Guide to Operation of Biological Resource Centers OECD (Organization for Economic Cooperation and Development). The Biological Resource Centers (BRC) must provide data describing the biological material and its origin to the Global Biological Resource Center Network (GBRCN). According to the guide, the BRCs should produce and store electronic data and catalogs based on validated information. The data also should be retained for traceability in accordance with the laws, regulations and policies. The trustees are responsible for ensuring the quality of the data associated with the biological material. The orientation of the quality standard ISO / IEC 17025:2005, is that shelf software used should be validated. By using the ISOs to production quality of packaged software, software engineering, overview and processes including documentary evidence, this work resulted in the validation of the Database Management System INFOGER_FUNGOS, an administration tool for the Collection of Reference Microorganisms evaluating its performance and quality. This system is subject to a process of intellectual property for data processing, generating high quality information for the reference services of this collection.
3

Avaliação dos Setores de Fungos de Referência e de Alimentos do INCQS como produtores de material de referência na área biológica / Evaluation of the Reference Fungal Division and Food Division of the National Institute of Quality Control in Health (INCQS / FIOCRUZ) as producers of reference material in the biological area

Forti, Tatiana January 2013 (has links)
Made available in DSpace on 2016-05-11T12:48:49Z (GMT). No. of bitstreams: 2 Mestrado_Tatiana-Forti.pdf: 9439996 bytes, checksum: a9b77f31ef52230c31281d71227fef5f (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2013 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / Esse trabalho teve como objetivo a avaliação dos Setores de Fungos de Referência e de Alimentos do Instituto Nacional de Controle de Qualidade em Saúde (INCQS/FIOCRUZ) como produtores de material de referência na área biológica. Seguindo as diretrizes internacionais para a acreditação de produtores de materiais de referência, um checklist, baseado nos requisitos do ABNT ISO Guia 34:2012 (Requisitos Gerais para a Competência de Produtores de Material de Referência) correlacionados com a ABNT NBR ISO/IEC 17025:2005 (Requisitos Gerais para a Competência de Laboratórios de Ensaio e Calibração), foi elaborado para ser aplicado nesses dois Setores. Complementando a aplicação do checklist, foi realizada uma auditoria interna formal, conforme a ABNT NBR ISO 19011:2012 (Diretrizes para auditorias de sistema de gestão), tendo como base os mesmos documentos do checklist. No Setor de Alimentos foi acompanhada a produção de Staphylococcus aureus P 4283 na matriz queijo para ser utilizado como item de ensaio em uma rodada de ensaio de proficiência. No Setor de Fungos de Referência a avaliação teve como escopo a produção de Cryptococcus Gattii INCQS 40324 e Cryptococcus neoformans INCQS 40323 para serem utilizados como material de referência pelos integrantes da Rede de Criptococose Brasil. Como o acervo de fungos do Setor de Fungos de Referência faz parte da Coleção de Micro-organismos de Referência em Vigilância Sanitária (CMRVS) do INCQS, foi, também, realizada uma avaliação deste Setor como Centro de Recursos Biológicos (CRB) segundo os requisitos das Diretrizes de Boas Práticas para CRB da Organização para Cooperação e Desenvolvimento Econômico (OCDE) para o domínio micro-organismos e da NIT-DICLA-061 rev02, norma interna da Divisão de Acreditação de Laboratórios-DICLA/Inmetro. O foco das avaliações foi na área de gestão dos processos produtivos e não abrangeram a área técnica/biológica e os estudos estatísticos.
4

Desenvolvimento de amostras padrão de referência para difratometria / Development of standart reference samples for diffractometry

Galvao, Antonio de Sant'Ana 05 May 2011 (has links)
Neste trabalho foram desenvolvidas amostras de materiais padrão de referência para difratometria de policristais. Materiais de alta pureza foram tratados mecânica e termicamente até atingirem as características necessárias para serem usados como materiais padrão de referência de alta qualidade, comparáveis àqueles produzidos pelo NIST. As medidas foram feitas inicialmente em vários difratômetros convencionais de laboratório de difração de raios X, com geometria de Bragg -Brentano, difratômetros de nêutrons e, posteriormente, em equipamento de alta resolução com fonte síncrotron. Os parâmetros de rede obtidos foram calculados pelo programa Origin e ajustados pelo Método dos Mínimos Quadrados. Esses ajustes foram comparados com os obtidos pelo Método de Rietveld, usando o programa GSAS através da interface gráfica EXPGUI, mostrando-se bastante satisfatórios. Os materiais obtidos foram alumina-α, ítria, silício, céria, hexaboreto de lantânio e fluoreto de lítio, que apresentaram qualidade semelhante e, em alguns casos, superiores aos padrões desenvolvidos e comercializados pelo NIST, a custos bem menores. / In this work, samples of standard reference materials for diffractometry of polycrystals were developed. High-purity materials were submitted to mechanical and thermal treatments in order to present the adequate properties to be used as high-quality standard reference materials for powder diffraction, comparable to the internationally recognized produced by the USA National Institute of Standards and Technology NIST, but at lower costs. The characterization of the standard materials was performed by measurements in conventional X-ray diffraction diffractometers, high resolution neutron diffraction and high-resolution synchrotron diffraction. The lattice parameters were calculated by extrapolation of the values obtained from each X-ray reflection against cos2θ by the Least-Squares Method. The adjustments were compared to the values obtained by the Rietveld Method, using the program GSAS. The materials thus obtained were the α-alumina, yttrium oxide, silicon, cerium oxide, lanthanum hexaboride and lithium fluoride. The standard reference materials produced present quality similar or, in some cases, superior to the standard reference materials produced and commercialized by the NIST.
5

Sistema de controle de estoque de materiais de referência de agrotóxicos / Friendly software for the control of pestides reference material

Melo, Artur Domingos Fonseca de January 2009 (has links)
Made available in DSpace on 2012-05-07T15:02:16Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 000011.pdf: 4487406 bytes, checksum: 233bd27015d9696418f0f45da4432774 (MD5) Previous issue date: 2010 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / O objetivo deste trabalho foi desenvolver um programa (software) para controlar o estoque de Materiais de Referência de Agrotóxicos (e outros itens de interesse), utilizados na determinação de resíduos de agrotóxicos em alimentos no Laboratório de Resíduos de Agrotóxicos do Departamento de Química do Instituto Nacional de Controle da Qualidade em Saúde INCQS da Fundação Oswaldo Cruz. Foi desenvolvido utilizando técnicas e ferramentas de Engenharia de Sistemas e o programa Epi Info para Windows 3.5.1, sendo denominado como Sistema de Controle de Estoque de Materiais de Referência de Agrotóxicos ou simplesmente ConPad. O programa ConPad, entre outras características, permite de uma forma amigável, realizar o registro de materiais de referência de agrotóxicos quando adquiridos, indicando quais daqueles materiais e quanto de cada composto está disponível no laboratório, bem como o gasto e a obsolescência dos mesmos, isto é quando novas aquisições deverão ser feitas. O programa ConPad poderá ser aperfeiçoado no futuro para registrar e informar sobre as soluções mãe de materiais de referência disponíveis no laboratório. / The objective of this work was to construct a software for controlling the stock of pesticide standards (and other items of interest) used on analyzing food for pesticide residues in the Pesticide Residues Laboratory - PRL of the Department of Chemistry, National Institute for the Quality Control on Health – INCQS, Oswaldo Cruz Foundation - FIOCRUZ. The ConPad software here described was thus elaborated using techniques and tools of systems engineering and the Epi Info for Windows 3.5.1 software. The ConPad software, among other characteristics, in a friendly way, performs the registration of the standards acquired by the PRL, indicates which standards and how much of each compound is available at any time in the laboratory, as well as the expenditure of standards, that is, which ones are about to run out or to surpasses the expire date, thus indicating which / when standards should be bought . The ConPad software will be implemented in the future to control also the stock and intermediate solutions of MRAs in use at the PRL.
6

Sistema de controle de estoque de materiais de referência de agrotóxicos / Friendly software for the control of pestides reference material

Melo, Artur Domingos Fonseca de January 2009 (has links)
Made available in DSpace on 2015-02-27T17:39:04Z (GMT). No. of bitstreams: 2 70.pdf: 4487406 bytes, checksum: 233bd27015d9696418f0f45da4432774 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / O objetivo deste trabalho foi desenvolver um programa (software) para controlar o estoque de Materiais de Referência de Agrotóxicos (e outros itens de interesse), utilizados na determinação de resíduos de agrotóxicos em alimentos no Laboratório de Resíduos de Agrotóxicos do Departamento de Química do Instituto Nacional de Controle da Qualidade em Saúde INCQS da Fundação Oswaldo Cruz. Foi desenvolvido utilizando técnicas e ferramentas de Engenharia de Sistemas e o programa Epi Info para Windows 3.5.1, sendo denominado como Sistema de Controle de Estoque de Materiais de Referência de Agrotóxicos ou simplesmente ConPad. O programa ConPad, entre outras características, permite de uma forma amigável, realizar o registro de materiais de referência de agrotóxicos quando adquiridos, indicando quais daqueles materiais e quanto de cada composto está disponível no laboratório, bem como o gasto e a obsolescência dos mesmos, isto é quando novas aquisições deverão ser feitas. O programa ConPad poderá ser aperfeiçoado no futuro para registrar e informar sobre as soluções mãe de materiais de referência disponíveis no laboratório. / O objetivo deste trabalho foi desenvolver um programa (software) para controlar o estoque de Materiais de Referência de Agrotóxicos (e outros itens de interesse), utilizados na determinação de resíduos de agrotóxicos em alimentos no Laboratório de Resíduos de Agrotóxicos do Departamento de Química do Instituto Nacional de Controle da Qualidade em Saúde – INCQS da Fundação Oswaldo Cruz.Foi desenvolvido utilizando técnicas e ferramentas de Engenharia de Sistemas e o programa Epi Info para Windows 3.5.1, sendo denominado como Sistema de Controle de Estoque de Materiais de Referência de Agrotóxicos ou simplesmente ConPad. O programa ConPad, entre outras características, permite de uma forma amigável, realizar o registro de materiais de referência de agrotóxicos quando adquiridos, indicando quais daqueles materiais e quanto de cada composto está disponível no laboratório, bem como o gasto e a obsolescência dos mesmos, isto é quando novas aquisições deverão ser feitas. O programa ConPad poderá ser aperfeiçoado no futuro para registrar e informar sobre as soluções mãe de materiais de referência disponíveis no laboratório.
7

Desenvolvimento de amostras padrão de referência para difratometria / Development of standart reference samples for diffractometry

Antonio de Sant'Ana Galvao 05 May 2011 (has links)
Neste trabalho foram desenvolvidas amostras de materiais padrão de referência para difratometria de policristais. Materiais de alta pureza foram tratados mecânica e termicamente até atingirem as características necessárias para serem usados como materiais padrão de referência de alta qualidade, comparáveis àqueles produzidos pelo NIST. As medidas foram feitas inicialmente em vários difratômetros convencionais de laboratório de difração de raios X, com geometria de Bragg -Brentano, difratômetros de nêutrons e, posteriormente, em equipamento de alta resolução com fonte síncrotron. Os parâmetros de rede obtidos foram calculados pelo programa Origin e ajustados pelo Método dos Mínimos Quadrados. Esses ajustes foram comparados com os obtidos pelo Método de Rietveld, usando o programa GSAS através da interface gráfica EXPGUI, mostrando-se bastante satisfatórios. Os materiais obtidos foram alumina-α, ítria, silício, céria, hexaboreto de lantânio e fluoreto de lítio, que apresentaram qualidade semelhante e, em alguns casos, superiores aos padrões desenvolvidos e comercializados pelo NIST, a custos bem menores. / In this work, samples of standard reference materials for diffractometry of polycrystals were developed. High-purity materials were submitted to mechanical and thermal treatments in order to present the adequate properties to be used as high-quality standard reference materials for powder diffraction, comparable to the internationally recognized produced by the USA National Institute of Standards and Technology NIST, but at lower costs. The characterization of the standard materials was performed by measurements in conventional X-ray diffraction diffractometers, high resolution neutron diffraction and high-resolution synchrotron diffraction. The lattice parameters were calculated by extrapolation of the values obtained from each X-ray reflection against cos2θ by the Least-Squares Method. The adjustments were compared to the values obtained by the Rietveld Method, using the program GSAS. The materials thus obtained were the α-alumina, yttrium oxide, silicon, cerium oxide, lanthanum hexaboride and lithium fluoride. The standard reference materials produced present quality similar or, in some cases, superior to the standard reference materials produced and commercialized by the NIST.
8

Avaliação da metodologia oficial in vivo e desenvolvimento de metodologia de inibição da citotoxicidade in vitro para determinação da potência do soro antibotrópico / Evaluation of the in vivo official methodology and development of an in vitro cytotoxicity inhibition methodology for potency determination of bothrops antivenom

Araújo, Humberto Pinheiro de January 2008 (has links)
Made available in DSpace on 2014-08-26T17:15:10Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 110.pdf: 1330597 bytes, checksum: 23ed5e7ab657bb9c29c75987db8a4052 (MD5) Previous issue date: 2008 / Este estudo buscou fazer um diagnóstico da situação atual da determinação da potência do soro antibotrópico e anticrotálico no Brasil, assim como propor e avaliar materiais de referência e metodologias alternativas (potência relativa e inibição da citotoxicidade in vitro) à metodologia oficial, com o objetivo de melhor avaliar a qualidade do soro antibotrópico utilizado no Brasil. Entre os anos de 2000 e 2006 o INCQS analisou 619 lotes de soros antiofídicos. Neste período, oito lotes foram considerados insatisfatórios (1,29%). O desempenho dos Padrões de Referência foi avaliado pela determinação da repetibilidade e da reprodutibilidade através do Coeficiente de Variação (CV). A repetibilidade para o lote BRA/BOT/04 foi de 16,57%, para BRA/BOT/05 de 13,17%, para BRA/CROT/01 de 31,82% e para BRA/CROT/02 de 17,36%. Em um estudo interlaboratorial foi avaliada a reprodutibilidade da DL50 do lote BRA/BOT/05 (CV = 16,76%) e a repetibilidade, que variou entre 7,48% e 10,88% nos diferentes laboratórios. A correlação de Pearson entre as determinações da potência dos soros antibotrópicos feitas pelo INCQS e laboratórios produtores foi de 0,286 o que é considerada uma correlação regular, a correlação das determinações da potência dos soros anticrotálicos foi de 0,002 o que é considerado insatisfatório. Nenhum dos venenos de referência apresentou perda de potência significativa nas condições ideais de armazenamento, demonstrando a boa estabilidade destas preparações. O soro BRAantiBot/01 apresentou uma potência de 6,62 mg/mL, com CV de 11%. A correlação de Pearson entre os valores obtidos pelas metodologias de potência relativa e absoluta foi de 0,785, o que é considerado como uma boa correlação. Foi desenvolvida uma metodologia in vitro para a determinação da atividade citotóxica do veneno de B. jararaca e do soro antibotrópico em células VERO. Esta metodologia se propõe como uma alternativa ao ensaio de letalidade em camundongos, metodologia oficial vigente. O valor da DCt50 do veneno BRABOT/05 foi de 2,92 ug/mL. A precisão interensaios para as determinações da DL50 pelo método dose Citotóxica 50% in vivo apresentou um CV de 12,27% enquanto que para as determinações in vitro da DCt50 o CV foi de 7,19%. A correlação de Pearson entre os resultados obtidos pelas duas metodologias foi de 0,96, o que é considerado uma correlação excelente. A potência de BRAantiBOT/01 pelo método in vitro foi de 3.092,6 mg/mL. A repetibilidade apresentou um CV de 56,81%. Neste trabalho foi proposto que a potência do soro antibotrópico seja expressa em Unidades Neutralizantes (UN) e que cada UN corresponda à capacidade de 1 mL de soro antibotrópico neutralizar 1 mg de Veneno Botrópico de Referência. / This study aims to make a diagnosis of the potency evaluation of bothropic and crotalic antivenoms in Brazil, as well as evaluate the performance of reference materials and alternatives (relative potency and in vitro cytotoxicity inhibition) to the pharmacopeic methods trying to improve the quality of antivenoms used in Brazil. Between 2000 and 2006, 619 lots of antivenoms were tested at INCQS. In this period, eight lots were unsatisfactory (1.29%). The Reference Standards performance was evaluated through the Coefficient of Variation (CV). The repeatability for the lot BRA/BOT/04 was 16.7%, for BRA/BOT/05 was 13.7%, for BRA/CROT/01 was 31.2% and for BRA/CROT/02 was 17.36%. The reproducibility for LD50 determinations of BRABOT/05 was evaluated through an interlaboratorial study and the CV was 16.76%, the repeatability varied between 7.48% and 10.88% in the participant laboratories. The correlation between the potency determinations for bothropic antiserum done by INCQS and manufacturers was 0.286, which is considered fair. The correlation for crotalic antiserum was 0.002 what is considered unsatisfactory. No one of the Reference Venoms lose potency significatively, giving evidence of a good stability profile in shelf conditions. The antiserum BRAantiBot/01 had a potency of 6.62 mg/mL, with a CV of 11%. The correlation between the values obtained through the methodologies of relative and absolute potency was 0.785, which is considered a good correlation. We also developed an in vitro methodology for the determination of the cytotoxic activity of B. jararaca venom and bothropic antivenom on VERO cells. This method is proposed as an alternative to the mice lethality test, the official methodology in vigour. The CtD50 of the reference venom BRABOT/05 was 2,92 ug/mL. The inter-assay precision for the LD50 (in vivo method) had a CV of 12.27%, while for the in vitro method (CtD50) the CV was 7.19%. The correlation between the results obtained by the two methods was 0.96, which is considered an excellent correlation. The potency of BRAantiBOT/01 obtained through the in vitro method was 3,092.6 mg/mL. The repeatability of this method has a CV of 56.81%. In this work, we propose that the bothropic antivenom potency should be expressed in Neutralizing Units (NU) and that each NU correspond to the ability of 1 mL of antivenom to neutralize 1 mg of Bothropic Reference Venom.

Page generated in 0.0799 seconds