• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 10
  • 10
  • 10
  • 10
  • 7
  • 5
  • 3
  • Tagged with
  • 199
  • 66
  • 56
  • 49
  • 35
  • 33
  • 29
  • 28
  • 27
  • 25
  • 24
  • 23
  • 22
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Análise dinâmica das vigas sandwich comprimidas

Villaça, Sérgio Fernando 07 1900 (has links)
Submitted by Fatima Fonseca (fatima.fonseca@sibi.ufrj.br) on 2017-07-27T15:50:24Z No. of bitstreams: 1 118078.pdf: 1059960 bytes, checksum: b80012a6f7a9a85bff1eb2c0d6549f51 (MD5) / Made available in DSpace on 2017-07-27T15:50:24Z (GMT). No. of bitstreams: 1 118078.pdf: 1059960 bytes, checksum: b80012a6f7a9a85bff1eb2c0d6549f51 (MD5) Previous issue date: 1970-07 / O problema abordado neste trabalho é o da determinação e análise das equações que regem o fenômeno de vibrações transversais de vigas sandwich submetidas a cargas axiais de compressão, bem como a análise das cargas críticas de instabilidade pelo processo dinâmico. Foram estudados os casos correspondentes a diversas condições de contorno, e obtidas as respectivas equações de frequência. São apresentados, também, gráficos e tabelas, através dos quais se pode verificar o comportamento das frequências naturais de vibração e da carga de instabilidade, em função da variação da rigidez ao cisalhamento das vigas sandwich. / The problem undertaken is this work is to determine and analyze the equations of lateral vibrations of sandwich beams with an axial compressive load, as well as the analysis of the instability loads by a dynamic method. Some cases, corresponding to several boundary conditions, were studied and the respective frequency equations were established. The behavior of the natural frequencies with the variation of the compressive load is plotted for several values of the shear stiffness of the sandwich beams. Numerical tables give the results for each case of boundary conditions.
82

Análise estática e dinâmica de vigas sandwich pelo método dos elementos finitos

Cardoso, Roberto 10 1900 (has links)
Submitted by Fatima Fonseca (fatima.fonseca@sibi.ufrj.br) on 2017-07-27T16:18:00Z No. of bitstreams: 1 133675.pdf: 1178137 bytes, checksum: 8949ee9e5bbd974c790632e00b21411d (MD5) / Made available in DSpace on 2017-07-27T16:18:00Z (GMT). No. of bitstreams: 1 133675.pdf: 1178137 bytes, checksum: 8949ee9e5bbd974c790632e00b21411d (MD5) Previous issue date: 1973-10 / O método dos Elementos Finitos é usado no presente trabalho visando uma análise estática e dinâmica de vigas sandwich submetidas a cargas axiais, bem como para a determinação das cargas críticas de instabilidade. Os elementos desenvolvidos são, também, aplicáveis a vigas onde deformações, devido ao esforço cortante, são significantes. Programas foram desenvolvidos para ambas as análises, estática e dinâmica. É feita a análise estática de uma viga sandwich em balanço e obtida a sua resposta a uma carga transversal dinâmica. É analisada, também, a convergência dos resultados e comparado o uso de ambas as matrizes de massa, consistente e diagonal. / In view of the static and dynamic analysis of sandwich beams submitted to axial loads as well as for the determination of instability critical loads the Finite Element Method has been used in the present work. The developed elements are also applied to beams where the shear strain has been taken into account. Programs have been developed both to the static and the dynamic analysis. The static analysis of a Cantilever sandwich beam has been done and for dynamical transversal load its response was obtained. The convergency of the results has been also analysed and compared the use of both consistent and diagonal mass matrices.
83

Vibrações de placas sandwich enrijecidas por barras conectoras

Freire, Antônio José de Alencastro Muniz 11 1900 (has links)
Submitted by Fatima Fonseca (fatima.fonseca@sibi.ufrj.br) on 2017-10-09T16:25:24Z No. of bitstreams: 1 154273.pdf: 858004 bytes, checksum: 5ad352d0bcb19d4cfbacea3bcc2b7cf8 (MD5) / Made available in DSpace on 2017-10-09T16:25:24Z (GMT). No. of bitstreams: 1 154273.pdf: 858004 bytes, checksum: 5ad352d0bcb19d4cfbacea3bcc2b7cf8 (MD5) Previous issue date: 1980-11 / Analisa as equações das vibrações transversais livres de placas sandwich retangulares, incluindo barras conectoras entre as faces que produzem enrijecimento do núcleo, sendo uniformemente comprimidas no seu plano médio, assim como o cálculo das cargas críticas de instabilidade, determinadas por um processo dinâmico. As equações das vibrações da placa sandwich foram obtidas substituindo as equações constitutivas e relações deformação-deslocamento nas equações de movimento. São apresentados gráficos fornecendo a variação das frequências naturais de vibração e da carga de instabilidade, com rigidez ao cisalhamento da placa variando as dimensões das barras conectoras. É elaborado também para uma dada placa, um gráfico de comportamento da carga de instabilidade com o modo de vibração e a rigidez das barras conectoras. / Analysis of the free transverse vibration equations of retangular sandwich-type plates including spaced transverse posts between the faces which introduce additional stiffness in the core, under compressive uniforme load acting in the midplane, as well as the determination of the critical loads by a dynamical process. The equations of vibration were obtained through the substitution of the constitutive equations into the equations of motion. Some results, as the variation of the natural frequencies and critical loads with the shear stiffness of the plate changing the sizes of the transverse posts were plotted. It is also plotted the influence on the critical load of the vibration mode and the transverse posts stiffness.
84

Dimensionamento ótimo de painéis fotovoltaicos usando enxame de partículas modificado para reduzir as perdas de energia e melhorar o perfil de tensão.

Souza, Jeane Silva de 29 February 2016 (has links)
Submitted by Morgana Silva (morgana_linhares@yahoo.com.br) on 2016-09-27T17:05:15Z No. of bitstreams: 1 arquivototal.pdf: 2911484 bytes, checksum: a40eec3093de5890811339c6b3e86fa7 (MD5) / Made available in DSpace on 2016-09-27T17:05:15Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2911484 bytes, checksum: a40eec3093de5890811339c6b3e86fa7 (MD5) Previous issue date: 2016-02-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work presents a method of sizing photovoltaic panels using modified Particle swarm (MPSO) in order to reduce power losses and improve the voltage profile. For implementation was used the PowerFactory® software, specifically programing language DIgSILENT (DPL). The proposed method was applied at the first time in the IEEE 13-bus system. After validating, it was applied to a real system, Federal University of Paraíba (UFPB). The results show that the proposed method have the ability to provide the best dimensions of photovoltaic panels distributed at the University, improving of the voltage profile and reducing energy losses / Este trabalho apresenta um método de dimensionamento de painéis fotovoltaicos usando enxame de partículas modificado (MPSO), a fim de reduzir as perdas de energia e melhorar o perfil de tensão. Para a implementação é utilizado o software PowerFactory®, especificamente a linguagem de programação em DIgSILENT (DPL). O método proposto foi aplicado inicialmente no sistema IEEE 13-barras. Após a validação, foi aplicada a um sistema real, Universidade Federal da Paraíba (UFPB). Os resultados mostram que o método proposto tem a capacidade de proporcionar as melhores dimensões de módulos fotovoltaicos distribuídos na micro rede da Universidade, melhorando o perfil de tensão e reduzindo as perdas de energia.
85

Desenvolvimento e avaliação de painéis de argamassa armada para aplicação em casas de agrovilas / Development and evaluation of mortar boards for housing construction in rural villages

Oliveira, Rui Carlos de 31 July 2013 (has links)
Made available in DSpace on 2015-03-26T13:23:52Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2626409 bytes, checksum: 689e2d612a3c7dcc3b669e91ad248063 (MD5) Previous issue date: 2013-07-31 / Brazilian agriculture has been transformed, with large agribusiness structures, better use of space and better use of available resources, and thus the rural workers have preferred to live close to the workplace, which are usually agricultural small villages. These locations require simple homes, fast built and inexpensive, such as modular buildings, made with prefabricated panels, reducing the assembly time on ready foundations, with significant reduction of remains. As this typology still needs investigations, this work was to develop and evaluate vertical (walls) and horizontal (ceiling) panels using mortar and pet plastic bottles. The results led to a modular measure of 1.05 m, and building measure of 1.04 m wide by 2.75 m high by 0.15 m thick. The modular panels was defined with female system on the side edges and upper, allowing joints on-line, l, t or cross, as well as the joint between vertical panels and slab. The form for the panels were made of wood, 6 cm thick, with half diameter pvc pipe diameter of 7.5 cm fixed on the sides and upper face of the panel to shape the female type fitting. The panels were armed with a metal cage with steel stirrups of ca-60 4.2 mm arranged in two directions, each 20 cm in longitudinal and 25 cm transversal way. Inside the metal cage were inserted eight columns of pet bottles and, lastly, the assembly was encased in wire netting. The surroundings of window and door panels were reinforced with 4 ca-60 8.0 mm steel bars in the longitudinal direction and with 4.2 mm stirrups every 15 cm. The mortar had weight trace of 1.0: 2.0 and a factor w/c = 0.45. In the compression test, the panels presented linear deformation, with deflections in a security range, thus far away from a possible breakage. In the hard body impact test, the panel surface was adequate, showing great performance. In the vertical compression test, based on prisms, made the calculation, it was concluded that the panel was suitable for use on walls of houses up to two floors. In the bending test of the slab panel with up to 8 kn of load, it was concluded that it can be used even for slab with public access. In the shear test of the slab panel, as the load was higher than that recommended for public access, the panel was approved to be used as a ceiling or floor. The masonry panels had its cost about 2.5 times smaller than the conventional masonry. Finally, the proposed modular system can be recommended both as wall and as slabs. / A agricultura brasileira vem se transformando, com grandes estruturas agroindustriais, melhor aproveitamento do espaço físico e melhor uso dos recursos disponíveis, e o trabalhador rural tem preferido morar próximo do local de trabalho, que normalmente são agrovilas. Estas localidades demandam casas com execução simples, rápida e econômica, como as edificações moduladas, confeccionadas com painéis pré-fabricados, com redução do tempo de montagem sobre fundações prontas e redução significativa de resíduos. Como esta tipologia ainda carece de investigações, objetivou-se com este trabalho desenvolver e avaliar painéis de fechamentos verticais (paredes) e horizontais (teto), empregando argamassa armada e garrafas de plástico tipo PET. Os resultados conduziram á uma medida modular de 1,05 m, com a medida de construção do painel de 1,04 m de largura, por 2,75 m de altura, por 0,15 m de espessura. Os painéis modulares foram definidos para terem sistema fêmea nas extremidades laterais e superior, permitindo junções em linha, l, t ou em cruz, assim como junção entre painéis verticais e de laje. As fôrmas dos painéis foram de madeira, com 6 cm de espessura, com meio diâmetro de tubo de pvc diâmetro de 7,5 cm, nas laterais e face superior do painel, para moldar o encaixe tipo fêmea. Os mesmos foram armados com uma gaiola metálica com estribos de aço ca-60 4,2 mm dispostos nas duas direções, a cada 20 cm na longitudinal e a cada 25 cm na transversal. Em seu interior foram inseridas 8 colunas de garrafas pet e, por fim, o conjunto foi envolto por tela de viveiro. Os painéis com janela e porta tiveram o seu entorno reforçados com 4 barras de aço ca-60 8,0 mm no sentido longitudinal e estribos de 4,2 mm, a cada 15 cm. A argamassa teve traço em peso de 1,0 : 2,0 e fator a/c = 0,45. No ensaio de compressão dos painéis, as deformações se apresentaram dentro de um inervalo de segurança e bem distante de uma possível ruptura. No ensaio de impacto de corpo duro, a superfície do painel se mostrou adequada, com ótimo desempenho. Nos ensaios de compressão vertical, através de prismas, feito o cálculo, pôde-se concluir que o painel é adequado para a utilização em paredes de residências de até dois pavimentos. Nos ensaios de flexão e de cisalhamento do painel de laje, com carregamento de até 8 kN, conclui-se que a mesma pode ser de piso com acesso ao público. A alvenaria com painéis teve o seu custo cerca de 2,5 vezes menor que as alvenarias convencionais. Por fim, o sistema modular proposto atende ao preconizado, quer como paredes ou como lajes.
86

Painéis de medium density fiberboard produzidos com adesivo alternativo / Panels medium density fiberboard produced with alternative round

Eugênio, Rafael Augusto Pinholati [UNESP] 02 December 2016 (has links)
Submitted by RAFAEL AUGUSTO PINHOLATI EUGENIO null (rafael.pinholati@duratex.com.br) on 2016-12-06T23:33:20Z No. of bitstreams: 1 DISSERTAÇÃO RAFAEL - MESTRADO Rev 4.pdf: 3957807 bytes, checksum: 74c157bc6d300c719cca57459b4455da (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-12-09T12:54:47Z (GMT) No. of bitstreams: 1 eugenio_rap_me_bauru.pdf: 3957807 bytes, checksum: 74c157bc6d300c719cca57459b4455da (MD5) / Made available in DSpace on 2016-12-09T12:54:47Z (GMT). No. of bitstreams: 1 eugenio_rap_me_bauru.pdf: 3957807 bytes, checksum: 74c157bc6d300c719cca57459b4455da (MD5) Previous issue date: 2016-12-02 / O trabalho consistiu na produção de painéis de MDF (Medium Density Fiberboard) em escala laboratorial utilizando o adesivo PVA (Poliacetato de Vinila), variando suas concentrações e realizando misturas com a resina comumente empregada neste processo, o adesivo a base de uréia-fomaldeído, onde foi avaliado além das características físicas e mecânicas dos painéis produzidos, também teve o intuito de verificar o desprendimento de formaldeído para o ambiente quando aplicado juntamente com a resina uréia-fomaldeído, e a avaliação dos perfis de densidades dos traços. As amostras foram confeccionadas com fibra de eucalipto, onde as dosagens do adesivo PVA seguiram as seguintes proporções: 30%, 50% e 70%, e para efeito de comparação com as amostras produzidas com a mistura de PVA foram fabricadas provas em branco com 100% uréia-formaldeído. No total foram produzidas 16 amostras, quatro painéis de cada traço, e retirados os corpos de prova que posteriormente foram avaliados conforme a NBR 15316-2:2015 para as condições secas. Todos os insumos foram fornecidos pelo fabricante de painéis Duratex SA, e os testes foram realizados nos laboratórios da empresa. O adesivo PVA mostrou-se bastante favorável, apresentando grande compatibilidade com os demais componentes da formulação, apresentando potencial para fabricação de MDF. Diversos traços conseguiram atender os requisitos da norma, com destaque para módulo de ruptura (MOR), módulo de elasticidade (MOE), obtidos atraves do ensaio de flexão estática, e o teor de umidade. Houve também uma discreta redução na emissão de formol em dois traços (T3 e T4), e na avaliação dos perfis de densidade foi constatado que a formulação dos traços não impactou nas densidades médias da espessura dos painéis. / The work consisted in the production of MDF (Medium Density Fiberboard) in laboratory scale using PVA adhesive (Polyacetate Vinyl Chloride), varying their concentrations and performing mixtures with commonly used resin in this process, the adhesive base of ureafomaldehyde, which was evaluated in addition to the physical and mechanical characteristics of the panels produced, also aimed to check the formaldehyde release to the environment when applied together with resin urea-fomaldehyde, and evaluation of the densities of the features profiles. The samples were made from eucalyptus fibers where PVA adhesive doses followed the following proportions: 30%, 50% and 70%, and for the purpose of comparison with the samples produced with the mixture of PVA blank tests were made with 100 % ureaformaldehyde. In total, we produced 16 samples, four panels of each stroke, and removed the specimens which were then evaluated according to NBR 15316-2: 2015 for dry conditions. All inputs were provided by the panel manufacturer Duratex SA, and the tests were performed in the company's laboratories. PVA adhesive proved to be very favorable, with high compatibility with the other components of the formulation, with potential for the production of MDF. Many features were able to meet the standard requirements, particularly modulus of rupture (MOR), modulus of elasticity (MOE), obtained through the bending, and moisture content test. There was also a slight reduction in formaldehyde emissions by two dashes (T3 and T4), and evaluation of density profiles was found that the formulation of the traits did not affect the average thickness of the thickness of the panels.
87

Análise da influência da adição de nanopartículas de ZnO nas propriedades físico-mecânicas e de transferência de calor em painéis de fibras de madeira / Analysis of the influence of the addition of ZnO nanoparticles on physical-mechanical properties and heat transfer in wood fiber panels

Silva, Ana Paula Santos da [UNESP] 21 February 2018 (has links)
Submitted by Ana Paula Santos da Silva (ana.paula1@outlook.com) on 2018-04-13T00:44:19Z No. of bitstreams: 1 Defesa Mestrado- versão final.pdf: 2552832 bytes, checksum: 9589b4e1630518c51f6b72f3850d78d9 (MD5) / Approved for entry into archive by Pamella Benevides Gonçalves null (pamella@feg.unesp.br) on 2018-04-13T17:50:34Z (GMT) No. of bitstreams: 1 silva_aps_me_guara.pdf: 2552832 bytes, checksum: 9589b4e1630518c51f6b72f3850d78d9 (MD5) / Made available in DSpace on 2018-04-13T17:50:34Z (GMT). No. of bitstreams: 1 silva_aps_me_guara.pdf: 2552832 bytes, checksum: 9589b4e1630518c51f6b72f3850d78d9 (MD5) Previous issue date: 2018-02-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O segmento de painéis à base de madeira tem se destacado no setor madeireiro pelo uso de tecnologia moderna em seus equipamentos e uso mais racional da matéria-prima. No entanto, a busca por produtos melhores e mais competitivos é constante tendo em vista o mercado ser bastante exigente. Sendo assim, definiu-se como objetivo deste estudo a adição de nanopartículas de óxido de zinco (ZnO) na fabricação de painéis de fibras de média densidade e avaliar as influências das mesmas nas propriedades físicas e mecânicas dos painéis produzidos com dois adesivos comerciais e ainda verificar a influência das nanopartículas na transferência de calor durante o processo de prensagem. Os painéis foram produzidos com adição de 0,5% e 1% de nanopartículas com base no peso seco de fibras e painéis testemunha com resina ureia-formaldeído (UF) e melamina-formaldeído (MF) e, os mesmos caracterizados a partir da ABNT NBR 15.316-2:2015. Durante o processo de prensagem através de sistema de aquisição de dados acoplado a um termopar foram obtidas as variações de temperatura do colchão ao longo dos dez minutos do ciclo de prensagem. A partir dos resultados pode-se concluir que o uso das nanopartículas na proporção de 0,5% de nanopartículas não indicou grandes interferências nas propriedades físico-mecânicas dos painéis estudados. A adição de 1% de nanopartículas tanto nos tratamentos com MF e UF interferiu de forma negativa na interação com o adesivo e, assim, reduziu as propriedades físicas e mecânicas dos painéis e, auxiliou a transferência de calor a partir do segundo ciclo de prensagem. / The wood-based panels stood out in the wood segment by the use of modern technology in their equipment and more rational use of the raw material. However, the demand for better and more competitive products is constant, given that the market is quite demanding. Thus, the aim of this study was to add zinc oxide (ZnO) nanoparticles in the production of medium density fiberboards and to evaluate their influence on the physical and mechanical properties of the panels produced with two commercial adhesives and to verify the influence of nanoparticles on the heat transfer during the pressing process. The panels were produced with 0.5% and 1% of nanoparticles based on the dry weight of fibers and control panels with ureaformaldehyde (UF) and melamine-formaldehyde resin (MF) and characterized by ABNT NBR 15.316-2:2015. During the pressing process through a data acquisition system coupled to a thermocouple, the temperature variations of the mattress were obtained during the ten minutes of the pressing cycle. From a preliminary analysis of the results it can be concluded that the use of nanoparticles in the proportion of 0.5% of nanoparticles did not indicate large interferences in the physical-mechanical properties of the panels studied. The addition of 1% of nanoparticles in both MF and UF treatments interfered negatively in the interaction with the adhesive and thus reduced the physical and mechanical properties of the panels and assisted the heat transfer from the second pressing cycle
88

Avaliação do desempenho de compensados de Pinus taeda submetidos a tratamento térmico e químico / Evaluation of Pinus taeda plywood performance subjected to heat and chemical treatment

Ferreira, Bruno Santos [UNESP] 03 August 2017 (has links)
Submitted by Bruno Santos Ferreira null (brunosferreira88@gmail.com) on 2017-09-26T18:33:14Z No. of bitstreams: 1 Tese Doutorado - versão final.pdf: 4467628 bytes, checksum: bfc17dcc9741a54483dd3b40927f6926 (MD5) / Approved for entry into archive by Monique Sasaki (sayumi_sasaki@hotmail.com) on 2017-09-28T13:09:13Z (GMT) No. of bitstreams: 1 ferreira_bs_dr_guara.pdf: 4467628 bytes, checksum: bfc17dcc9741a54483dd3b40927f6926 (MD5) / Made available in DSpace on 2017-09-28T13:09:13Z (GMT). No. of bitstreams: 1 ferreira_bs_dr_guara.pdf: 4467628 bytes, checksum: bfc17dcc9741a54483dd3b40927f6926 (MD5) Previous issue date: 2017-08-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O setor madeireiro tem crescido nos últimos anos no Brasil, visto que o país possui vastas áreas com florestas de reflorestamento. Entretanto, com o passar dos anos, tem crescido a consciência de uma melhor utilização das matérias-primas, inclusive da madeira. Neste contexto, surgem os painéis à base de madeira, os quais utilizam melhor as toras, que podem ser de diferentes dimensões. Dentre estes painéis, destaca-se o compensado laminado, que é um painel produzido com um número ímpar de lâminas de madeira, dispostas perpendicularmente umas às outras com relação a direção da grã. Este painel possui ampla utilização, principalmente na indústria moveleira e na construção civil, podendo ser utilizado em construções do tipo wood frame. Além disso, o compensado necessita passar por algum processo de tratamento contra o ataque de fungos, insetos e intempéries. Assim, este estudo teve o objetivo de analisar a influência de tratamentos preservativos nas propriedades físicas e mecânicas do compensado laminado de Pinus taeda. Para isso, foi realizada a termorretificação, com três diferentes temperaturas (160°C, 180°C e 200°C) e o tratamento químico com CCA. Foram realizados os tratamentos das lâminas antes da produção do compensado e os tratamentos dos painéis já produzidos, sem prévio tratamento das lâminas, com o intuito de avaliar qual forma de tratamento é a mais adequada. Foram realizadas as análises de teor de extrativos totais, molhabilidade das lâminas, microscopia eletrônica de varredura e testes físicos e mecânicos. Os resultados obtidos mostraram que os tratamentos de termorretificação e o tratamento com CCA melhoraram a estabilidade dimensional do painel compensado, devido às alterações químicas ocorridas na madeira. Além disso, ambos os tratamentos diminuíram a resistência mecânica à flexão estática e a qualidade de colagem. Entretanto, todos os tratamentos continuaram a atender as especificações mínimas de órgãos normativos. Com base em todas as análises concluiu-se que a termorretificação do painel a 200°C mostrou-se mais adequada. / The forestry sector has grown recently in Brazil, since the country has vast reforestation fields. However, over the years, there has been growing the consciousness of a better use of raw materials, including wood. In this context arise the wood based panels, which make better use of logs, which may be of different dimensions. Among these panels is highlighted the plywood, which is a panel produced with an odd number of wood veneers arranged perpendicularly to each other with respect to the grain direction. This panel has wide application, especially in the furniture industry and in construction and can be used in wood frame type construction. Besides that, the plywood needs to undergo some treatment process against the attack of fungi, insects and weatherproof. Thus, this study aims to analyze the influence of preservative treatments on physical and mechanical properties of Pinus taeda plywood. To this were performed the heat treatment with three different temperatures (160 °, 180 ° C and 200 ° C) and chemical treatment with CCA. It was carried out the veneers treatments before the production of plywood and the panel treatment, without prior veneers treatment, in order to assess which form of treatment is most appropriate. The analyzes of extractive content, veneers wettability, scanning electron microscopy and physical and mechanical tests were performed. The results showed that the heat treatment and CCA treatment improved the dimensional stability of the plywood due to chemical changes in the wood. In addition, both treatments decreased mechanical strength in static bending and bonding quality. However, all treatments continued to meet the minimum specifications of specialized organs. Based on all the analyzes it was concluded that the heat treatment of the panel at 200°C was more adequate.
89

Desempenho físico-mecânico de painéis LVL de pinus tropicais da região de São Paulo /

Gabriel, Maria Sílvia Chiaradia, 1970- January 2007 (has links)
Resumo: Este trabalho teve por objetivo principal a avaliação do desempenho físico-mecânico de painéis de lâminas paralelas LVL (Laminated venner lumber) de Pinus tropicais, classificando-se as lâminas em classes de qualidade (baixo e alto módulos de elasticidade), usando-se para isto métodos não-destrutivos, como ultra-som e ondas de tensão. As avaliações foram realizadas em painéis com lâminas de espessura de 2,2 mm, provenientes da Indústria de Madeiras Caribea Ltda., localizada no município de São Manuel, SP. Foram confeccionados painéis LVL de 13 e 25 lâminas, com quatro tipos de tratamento, com as lâminas previamente classificadas: a) T1-LVL homogêneo 1 (produzido somente com lâminas classificadas com alto módulo de elasticidade dinâmico) b) T2-LVL homogêneo 2 (produzido somente com lâminas classificadas com baixo módulo de elasticidade dinâmico ) c) T3-LVL com lâminas combinadas (lâminas de alto módulo de elasticidade dinâmico na capa e contracapa e baixo módulo de elasticidade dinâmico no miolo) d) T4-LVL não homogêneo (com lâminas alternadas - uma com alto módulo, e outra com baixo módulo de elasticidade alternadamente) As propriedades dos painéis foram avaliadas pelos métodos nãodestrutivos de ondas de tensão (stress wave method) e ultra-som, determinando-se, respectivamente, o módulo dinâmico (Ed.) e a constante dinâmica (CLL) de cada painel. Com os corpos-de-prova retirados dos painéis foram realizados ensaios de flexão estática, 2 cisalhamento longitudinal, compressão paralela e perpendicular às fibras, resistência da colagem ao esforço de cisalhamento, teor de umidade e densidade, seguindo-se as recomendações das normas ASTM 5456 e o Projeto 31:000.05-001/3 para Painéis de madeira compensada, da ABNT. Na avaliação da qualidade dos painéis os valores médios das propriedades do LVL foram comparados...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This paper had the main objective of evaluating physical and mechanical performance of LVL panels made from tropical pinus, with the previous classification of the veneers according to its MOE (high and low modulus of elasticity), obtained from non-destructive tests (ultrasound and stress wave methods). Evaluations were carried in commercial dimension panels made with 2,2 mm thick veneers from "Industria de Madeiras Caribea Ltda", located at Sao Manuel, São Paulo State, southeast of Brazil. Panels with 13 and 25 veneer were made considering four distinct treatments (three boards for each thickness and treatment) as follows: a) T1 (homogeneous superior) - LVL made entirely of higher MOE veneer; b) T2 (homogeneous inferior) - LVL made entirely of low-grade MOE veneer; c) T3 (rational) - LVL made with higher MOE in face veneer and lower MOE in core veneer; d) T4 (combined) - boards made with combined and alternated veneer with higher and lower MOE. Panels were submitted to non-destructive evaluation, in order to obtain their dynamic modulus of elasticity (Ed - stress wave method) and dynamic constant (CLL - ultrasound method). Specimens of the boards were tested under static bending, longitudinal shear, compression parallel and normal to the grain. For all specimens were evaluated density and humidity. All physical and mechanical tests were done according to ASTM D 5456 Code and CE 31:000.05-001/1 - First draft of the new Brazilian Code for Plywood...(Complete abstract click electronic access below) / Orientador: Adriano Wagner Ballarin / Coorientador: Hernando Alfonso Lara Palma / Banca: Takasho Yojo / Banca: Luiz Antonio Vasques Hellmeister / Banca: Mascos Antonio Rezende / Banca: Vladimir Eliodoro Costa / Doutor
90

Aproveitamento de madeiras tropicais para confecção e avaliação de painéis aglomerados com mistura de partículas e resinas alternativas /

Negrão, Wilson Henrique. January 2013 (has links)
Orientador: Sérgio Augusto Mello da Silva / Coorientador: Maria da Consolação Fonseca Albuquerque / Banca: Maximiliano dos Anjos Azambuja / Banca: Francisco Antonio Rocco Lahr / Resumo: Este trabalho constitui-se de estudos para confecção e avaliação de painéis aglomerados com quatro espécies de madeiras tropicais: Cedrela odorata (Cedrinho), Cordia goeldiana (Cordia), Ficus insípida (Ficus) e Ceiba pentandra (Paineira). Para confecção dos painéis empregou-se 10 % de adesivo em três traços utilizando-se resina ureia formaldeído, resina poliuretana bicomponente derivado de óleo de mamona e resina poliuretana monocomponente PURBOND HB SB109, respectivamente. A partir da caracterização física e mecânica realizada com base na NBR 14810 e ASTMD-1037, foram determinados valores de Densidades iguais a: 0,65; 0,73 e 0,61g/cm3, Umidade igual a: 7,61; 6,56 e 7,46%, Inchamento após 2h igual a: 12,94; 3,46 e 31,33 %; Absorção após 2h igual a: 54,81; 6,44 e 62,54 %, respectivamente e Módulo de Resistência à Flexão (MOR) igual a: 20,36; 19,49 e 19,30 MPa; Resistência à Tração Perpendicular (RTP) igual a:0,86; 1,17; 0,53 MPa, respectivamente. Os valores de RTP e Densidade foram submetidos à análise de regressão linear, sendo verificado que os coeficientes de determinação da reta tendem para um, possibilitando concluir que as propriedades de adesão interna e densidade estão fortemente correlacionadas e podem propiciar boas qualidades aos painéis / Abstract: This work consists of studies for fabrication and evaluation of particleboards of four species of tropical woods: Cedrela odorata (Cedrinho), Cordia goeldiana (Cordia), Ficus insípida (Ficus) and Ceiba pentandra (Paineira). To produce the particleboards was used 10% of resin in three stages using formaldehyde urea, polyurethane bicomponent derived from castor bean oil and a monocomponent polyurethane adhesive called PURBOND HB SB109, respectively. From the physical and mechanical characterization performed based on NBR 14810 and ASTM D-1037, were determined values of Density equal to: 0,65; 0,73 and 0,61g/cm³, Humidity equal to: 7,61; 6,56 and 7,46%, Swelling after 2 hours equal to: 12,94; 3,46 and 31,33%; Absorption after 2 hours equal to: 54,81; 6,44 and 62,54%, respectively and Modulus of Resistance to Flexion (MOR) equal to: 20,36; 19,49 and 19,10 MPa; Perpendicular Traction Resistance (RTP) equal to: 0,86; 1,17; 0,53 MPa, respectively. Then the values of RTP and Density were analyzed bilinear regression, being verified that the coefficients of determination of the line tend to one, allowing concluding that the internal adhesion properties and density are strongly correlated and can provide good qualities to the panels / Mestre

Page generated in 0.0367 seconds