Spelling suggestions: "subject:"paper based"" "subject:"paper eased""
51 |
Novel methods for improving rapid paper-based protein assays with gold nanoparticle detectionLama, Lara January 2017 (has links)
This thesis describes methods for improving sensitivity in rapid singleplex and multiplex microarray assays. The assays utilize the optical characteristics of colloidal gold nanoparticles for the colorimetric detection of proteins. Multiplexed detection in sandwich immunoassays is limited by cross-reactivity between different detection antibodies. The cross-reactivity between antibodies can contribute to increased background noise - decreasing the Limit-of-Detection of the assay - or generate false positive signals. Paper I shows improved assay sensitivity in a multiplexed vertical flow assay by the application of ultrasonic energy to the gold nanoparticles functionalized with detection antibodies. The ultrasonication of the antibody conjugated gold nanoparticles resulted in a 10 000 fold increase in sensitivity in a 3-plex assay. COMSOL Multiphysics was used to simulate the acoustical energy of the probe used in Paper I for obtaining an indication of the size and direction of the forces acting upon the functionalized gold nanoparticles. In Paper II, it was studied if different gold nanoparticle conjugation methods and colorimetric signal enhancement of the gold nanoparticle conjugates could influence the sensitivity of a paper-based lateral flow microarray assay, targeting cardiac troponin T for the rapid diagnostics of acute myocardial infarction. Ultrasonication and signal enhancement of the detection gold nanoparticles has the potential of improving the sensitivity of paper based assays and expanding their potential future applications. / <p>QC 20170911</p>
|
52 |
PRINTING AND CHARACTERIZATION OF INKS FOR PAPER-BASED BIOSENSORSWang, Jingyun 04 1900 (has links)
<p>This thesis describes solutions to many of the challenges in the development of paper-based biosensors. Coupling techniques in analytical biochemistry with knowledge of paper science and technology, advances are described in the areas of: the influence of paper surface chemistry on bioactivity; optimizing bioactive ink formulation; the printing of paper supported microfluidic channels; and, the characterization of complex sensors based on printed sol-gel material layers.</p> <p>The stability of paper-immobilized antibodies under various conditions was first studied using both untreated filter paper and PAE-treated paper. Antibody stability decreased with increasing temperature and relative humidity. Paper treated with PAE had no significant influence on antibody stability under the experimental conditions. The experimental result was also encapsulated in an empirical equation to predict the impact of printing and coating operations on antibody activity.</p> <p>The influence of paper sizing agent (AKD) on the adsorption and inactivation of antibody was also investigated. The preliminary study showed that the small amount of AKD improved the antibody adsorption on paper and also did not interfere antibody activity. Therefore, packaging papers containing sizing agents can be used as a substrate for antibody immobilization.</p> <p>Two strategies to fabricate hydrophobic barriers were developed, based on sol-gel derived MSQ material. The first method is based on ink-jet printing a highly basic solution onto MSQ-impregnated filter paper to re-exposing the cellulose and producing a hydrophilic patterned region. The second method is direct ink-jet printing of MSQ onto paper to outline the hydrophobic walls bordering the hydrophilic channels. The resistance of the barriers to surfactants and organic solvents was tested. The functionality of MSQ-based devices was further demonstrated by using a colorimetric assay for <em>E. coli </em>detection.</p> <p>Multiple-stage inkjet printing of sol-gel based bioink onto porous filter paper for enzyme immobilization was characterized by various methods. Confocal microscope and SEM/TEM images confirmed the formation of sol-gel and enzyme composite material on the paper fibers without cracking. The protease assay proved that the entrapment of enzyme molecules improved with the increasing amount of the sol-gel derived material printed on paper. The top layer of sol-gel ink was found to play a major role in protection against enzyme proteolysis, while the bottom layer of sol-gel ink was found to be necessary to prevent the potential inhibition of enzyme by the cationic polymer.</p> / Doctor of Philosophy (PhD)
|
53 |
Paper-Based Sensors for Contaminant Detection Using Surface Enhanced Raman SpectroscopyJain, Ishan 29 June 2015 (has links)
Surface enhanced Raman spectroscopy (SERS) is highly promising analytical technique for trace detection of analytes. It is particularly well suited for environmental analyses due to its high sensitivity, specificity, ease of operation and rapidity. The detection and characterization of environmental contaminants, using SERS is highly related to the uniformity, activity and reproducibility of the SERS substrate.
In this thesis, SERS substrates were produced by gold nanoparticle formation on wax patterned chromatography paper. In situ reduction of hydrogen tetrachloroaurate (gold precursor) by trisodium citrate dihydrate (reducing agent) was used to produce gold nanoparticles within a paper matrix. These gold nanoparticle based SERS substrates were analyzed by FE-SEM, UV-Vis and Raman spectroscopy. This work discusses the SERS signal enhancements for Raman active MGITC dye for a series of substrates prepared by in situ reduction of gold salt and pre-produced gold nanoparticles. UV-Vis analysis was performed to understand the effect of different molar ratio (reducing agent to gold precursor) and reaction time on the size and shape of the localized surface plasmon resonance (LSPR) band that dictates the SERS enhancements. It was concluded that lower molar ratio (1:1 and 2:1) of citrate-to gold produced better SERS signal enhancements and broader LSPR band. Therefore, use of lower molar ratio (MR) was recommended for paper-based substrates using in situ-based reduction approach. / Master of Science
|
54 |
Desenvolvimento de sensores eletroquímicos e colorimétricos para aplicações em amostras de interesse forense / Development of electrochemical and colorimetric sensors for application in forensic interest samplesAraujo, William Reis de 07 June 2016 (has links)
Esta tese apresenta os estudos e esforços visando ao desenvolvimento de sensores químicos para aplicações diversas na área forense. Foram desenvolvidos métodos eletroanalíticos para detecção e quantificação de alguns compostos comumente encontrados na adulteração de amostras de drogas de abuso (procaína, fenacetina, aminopirina, paracetamol, levamisol), além da cocaína e estudos fundamentais sobre o comportamento eletroquímico desses compostos. Empregaram-se também métodos eletroquímicos para quantificação de compostos tóxicos e perigosos como explosivos (ácido pícrico) e melamina por exemplo. Os trabalhos utilizando sensores eletroquímicos contemplam modificações eletroquímicas das superfícies eletródicas, utilização de sensores com polímeros molecularmentes impressos (MIP) e eletrodos descartáveis em papel utilizando diferentes técnicas voltamétricas e amperométricas, eletrodo disco rotatório (EDR) e microbalança de cristal de quartzo. Além da fabricação de dispositivos analíticos descartáveis em papel empregando detecção eletroquímica utilizou-se também a detecção colorimétrica para quantificação de alguns dos principais adulterantes de amostras de apreensão de cocaína, como procaína e fenacetina, bem como análises e discriminações de compostos explosivos (peroxi e nitro compostos) nessas plataformas portáteis e de baixo custo. Os métodos foram sempre desenvolvidos visando característicos como: facilidade, praticidade, baixo custo e portabilidade para análises diretamente no local de medida com mínima infraestrutura laboratorial. Por fim, são apresentados alguns estudos realizados durante estágio de pesquisa no exterior (Universidade da Califórnia - San Diego (UCSD)) na área de Wearable Sensors, em que foram desenvolvidos métodos para análises de micronutrientes no suor (zinco) e um metabólito (ácido úrico) na saliva usando sensores aplicados diretamente no corpo humano. / This thesis shows studies and efforts to the development of chemical sensors for different applications in the forensic field. Electroanalytical methods were developed for detection and quantification of some compounds (procaine, phenacetin, aminopyrine, acetaminophen, levamisole) commonly found in the drug of abuse adulteration process and cocaine, as well as, fundamental studies about the electrochemical behavior of these compounds. It was also employed electrochemical methods for quantification of hazardous compounds such as explosives (picric acid) and melamine. Analytical methods with electrochemical sensors included electrochemical modification of electrodic surfaces, molecularly imprinted polymers (MIP), and paper disposable electrochemical devices using different voltammetric and amperometric techniques, rotating disc electrode (RDE) and quartz crystal microbalance. In addition to the fabrication of paper disposable analytical devices with electrochemical detection, it was also used the colorimetric detection to quantify some of the major adulterants in cocaine seizure samples, such as procaine and phenacetin, as well as analysis and discrimination of explosive compounds (peroxy and nitro explosives) in these low cost portable platforms. All proposed methods were always developed aming at theses characteristics: ease, convenience, low cost and portability for analysis directly at the measurement site with minimal laboratory infrastructure. Finally, we presented some studies conducted during research internship abroad (University of California - San Diego (UCSD)) in the area of Wearable Sensors, which have been developed methods for micronutrient analysis in sweat (Zn) and a metabolite (Uric Acid) in saliva using sensors applied directly to the human body
|
55 |
Funcionalização de celulose para ensaios bioanalíticos em dispositivos microfluídicos baseados em papel (μPADs) / Cellulose modification for bioanalytical assays on paper-based microfluidic devices (µPADs)Morbioli, Giorgio Gianini 09 June 2015 (has links)
A funcionalização da matriz celulósica é um ponto essencial para o aprimoramento dos dispositivos microfluídicos baseados em papel (µPADs). Ela permite minimizar o preparo de amostras e a interferência do usuário, principais fontes de erro no processo analítico. A oxidação da celulose durante uma hora com m-periodato de sódio e a imobilização química de enzimas a partir da formação de bases de Schiff (iminas), via a adição direta da enzima ao substrato oxidado sem a necessidade de outras etapas, é um processo rápido e de baixo custo, apresentando grande potencialidade de aplicação nos dispositivos microfluídicos em papel. A enzima glicose oxidase imobilizada na celulose, com a adição do estabilizante trealose, apresentou elevada atividade catalítica - de 31,9 ± 5,5 mmol L-1 para a enzima não imobilizada a 14,8 ± 2,0 mmol L-1 para a enzima imobilizada e com o estabilizante - além de apresentar maior homogeneidade de sinal, condições desejáveis em testes rápidos em papel. A confecção de dispositivos em papel via impressão em cera alia rapidez e baixo custo de produção, e o arranjo em camadas para originar dispositivos tridimensionais (3D) permite ampliar as funcionalidades dos dispositivos em duas dimensões, tal como o tratamento individualizado de camadas e o armazenamento de reagentes no próprio dispositivo. O método da adição de padrão para obtenção de curvas analíticas no próprio microchip em papel surge como alternativa às curvas analíticas externas, minimizando a manipulação e o preparo de amostras. O uso do ácido 2,2’-azino-bis (3-etilbenzotiazolina-6-sulfônico) - ABTS como indicador redox para as reações enzimáticas e o método de adição de padrão nos µPADs apresentou boa correlação com um modelo de crescimento e saturação de Michaelis-Menten (r2 = 0,8723) na faixa de 0 a 10 mmol L-1, e a utilização da faixa linear para quantificação de glicose (0 a 3 mmol L-1) apresentou grande correlação linear com a concentração estimada pelas curvas de adição de padrão (r2 = 0,959), demonstrando a potencialidade do método. A união da tecnologia desses dispositivos em papel com a de um software automatizado de reconhecimento de imagens (PAlizer) torna instantânea a obtenção de resultados, eliminando-se a necessidade de intervenção humana no processo, tornando os testes em papel mais robustos, reprodutíveis e rápidos. Com o contínuo aperfeiçoamento das funcionalidades e potencialidades dos dispositivos microfluídicos em papel espera-se que os testes diagnósticos de baixo custo atinjam àqueles que deles necessitam, contribuindo para a saúde da população. / Functionalization of a cellulosic matrix is essential for the success of the paper-based microfluidic analytical devices (µPADs). It allows minimization of sample preparation and user interference, both being major sources of errors in the analytical process. Cellulose oxidation with sodium m-periodate during one hour and the direct chemical immobilization of enzymes on it by Schiff-base (imines) formation, which is made by direct insertion of the enzyme on the oxidized substrate without subsequent steps, is a fast and low cost process of immobilization, presenting great potential of application in paper-based microfluidic analytical devices. The glucose oxidase enzyme immobilized on cellulose, with the addition of trehalose stabilizer presented enhanced catalytic activity - from 31.9 ± 5.5 mmol L-1 for the non-immobilized enzyme to 14.8 ± 2.0 mmol L-1 for the immobilized enzyme with the stabilizing agent - also presenting greater signal homogeneity, which are ideal characteristics in a paper-based rapid test. Wax printing is a simple, inexpensive and fast method by which micro-devices can be fabricated. Additionally, the stacking of layers originating tridimensional devices (3D) allow for the improvement of functionalities of 2-dimensional ones, such as individualized layer treatment and reagent storage at different layers in the same device. Standard addition to analytical curves in paper-based microchips is an alternative to external analytical curves, minimizing handling/sample preparation. The use of 2,2\'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid - ABTS redox indicator with the enzymatic reactions and the standard addition method in µPADs presented a good correlation in a growth and saturation Michaelis-Menten model (r2 = 0.8723), in the range of 0 to 10 mmol L-1, and the usage of the linear range to the glucose quantification (0 to 3 mmol L-1) presented a high linear correlation with the estimated concentration from the standard addition curves (r2 = 0.959), showing the potentiality of the method. The coupling of such paper-based devices to automated image analysis software, such as \'PAlizer\', turns the data acquisition process instantaneous, eliminating the need of human intervention during the process, making it more robust, reproducible and rapid. Expectations lie in improving the devices functions and potential so that these low-cost diagnostic devices can one day reach those who need them, contributing significantly to public health.
|
56 |
Desenvolvimento de sensores químicos de baixo custo visando ao monitoramento da qualidade e da potabilidade de águas / Development of low-cost chemical sensors aiming at monitoring water quality and potabilitySilva, José Ricardo da 30 October 2018 (has links)
A falta de acesso à água potável ainda é um problema de saúde pública no Brasil. O desenvolvimento de novos métodos analíticos de baixo custo para o reconhecimento de amostras contaminadas é uma necessidade, pois análises laboratoriais estão fora da realidade socioeconômica da população mais vulnerável. Visando contribuir para a resolução deste problema, esta tese apresenta esforços para o desenvolvimento de métodos de baixo custo para a análise de qualidade de águas ambientais. Foi estudada a associação de ferramentas quimiométricas com sensores voltamétricos para tentar discriminar amostras de águas contaminadas com espécies eletroativas. O modelo desenvolvido foi capaz de discriminar de forma satisfatória amostras contaminadas contendo chumbo(II), cobre(II), zinco(II) e nitrito. Os esforços para a redução do custo das análises também focaram no desenvolvimento de sensores com materiais de baixo custo. Um dos dispositivos voltamétricos propostos foi capaz de quantificar metais tóxicos e pesticidas, utilizando papel, grafite e cera. Foi desenvolvido também um sistema de agitação por som que resultou em um aumento significativo da sensibilidade dos dispositivos voltamétricos portáteis permitindo a quantificação de chumbo(II) até 48 nmol L-1, cádmio(II) até 370 nmol L-1 e zinco(II) até 340 nmol L-1. Outro sensor voltamétrico foi confeccionado utilizando apenas papelão como matéria prima, para o qual um laser de CO2 foi utilizado pela primeira vez com o intuito de pirolisar a superfície do papelão gerando estruturas de carbono condutoras. Sensores colorimétricos em papel foram testados com sucesso para a quantificação de fluoreto até 500 µmol L-1 em amostras de água mineral utilizando fotografias retiradas por um telefone celular para a construção de modelos12 de calibração. Com outro sistema colorimétrico em papel foi possível medir o pH de amostras utilizando um método de calibração multivariada. Como mostrado neste trabalho, o desenvolvimento e a integração dos dispositivos analíticos em papel é uma alternativa abrangente, confiável e de baixo custo para a análise da qualidade de águas ambientais. / The lack of access to safe water remains as a public health problem in Brazil. The development of new analytical methods for low cost contaminated samples recognition is necessary since the complete laboratorial procedures are away from the reality of the most socioeconomic vulnerable population. In order to contribute to solve this problem, this thesis shows our efforts to develop new low-cost analytical methods to evaluate environmental waters quality. The combination of chemometric tools with voltammetric sensors was studied to discriminate contaminated water samples with electroactive species. The proposed model was able to discriminate potable and contaminated samples containing lead(II), copper(II), zinc(II) and nitrite species. Efforts to reduce the analysis cost have also focused on the development of sensors using low-cost materials. A proposed voltammetric device fabricated with paper, graphite and wax was able to quantify heavy metals and pesticides. The use of a sound agitation system for the portable voltammetric devices resulted in a significant increase in the sensitivity allowing the quantification of lead(II) above 48 nmol L-1, cadmium(II) above 370 nmol L-1 e and zinc(II) above 340 nmol L-1 . Another voltammetric sensor was made for the first time using only cardboard as material and a CO2 laser to pyrolyze the cardboard surface generating conductive carbon structures. Paper colorimetric sensors were successfully tested for fluoride quantification in spring water samples based on photographs taken by a smartphone with a LOQ of 500 µmol L-1. Another paper colorimetric system was capable to measure the pH of samples using a multivariate calibration method. As shown in this thesis, the development and integration of analytical paper-based devices is a reliable and low-cost alternative for water quality analysis
|
57 |
Desenvolvimento de sensores químicos de baixo custo visando ao monitoramento da qualidade e da potabilidade de águas / Development of low-cost chemical sensors aiming at monitoring water quality and potabilityJosé Ricardo da Silva 30 October 2018 (has links)
A falta de acesso à água potável ainda é um problema de saúde pública no Brasil. O desenvolvimento de novos métodos analíticos de baixo custo para o reconhecimento de amostras contaminadas é uma necessidade, pois análises laboratoriais estão fora da realidade socioeconômica da população mais vulnerável. Visando contribuir para a resolução deste problema, esta tese apresenta esforços para o desenvolvimento de métodos de baixo custo para a análise de qualidade de águas ambientais. Foi estudada a associação de ferramentas quimiométricas com sensores voltamétricos para tentar discriminar amostras de águas contaminadas com espécies eletroativas. O modelo desenvolvido foi capaz de discriminar de forma satisfatória amostras contaminadas contendo chumbo(II), cobre(II), zinco(II) e nitrito. Os esforços para a redução do custo das análises também focaram no desenvolvimento de sensores com materiais de baixo custo. Um dos dispositivos voltamétricos propostos foi capaz de quantificar metais tóxicos e pesticidas, utilizando papel, grafite e cera. Foi desenvolvido também um sistema de agitação por som que resultou em um aumento significativo da sensibilidade dos dispositivos voltamétricos portáteis permitindo a quantificação de chumbo(II) até 48 nmol L-1, cádmio(II) até 370 nmol L-1 e zinco(II) até 340 nmol L-1. Outro sensor voltamétrico foi confeccionado utilizando apenas papelão como matéria prima, para o qual um laser de CO2 foi utilizado pela primeira vez com o intuito de pirolisar a superfície do papelão gerando estruturas de carbono condutoras. Sensores colorimétricos em papel foram testados com sucesso para a quantificação de fluoreto até 500 µmol L-1 em amostras de água mineral utilizando fotografias retiradas por um telefone celular para a construção de modelos12 de calibração. Com outro sistema colorimétrico em papel foi possível medir o pH de amostras utilizando um método de calibração multivariada. Como mostrado neste trabalho, o desenvolvimento e a integração dos dispositivos analíticos em papel é uma alternativa abrangente, confiável e de baixo custo para a análise da qualidade de águas ambientais. / The lack of access to safe water remains as a public health problem in Brazil. The development of new analytical methods for low cost contaminated samples recognition is necessary since the complete laboratorial procedures are away from the reality of the most socioeconomic vulnerable population. In order to contribute to solve this problem, this thesis shows our efforts to develop new low-cost analytical methods to evaluate environmental waters quality. The combination of chemometric tools with voltammetric sensors was studied to discriminate contaminated water samples with electroactive species. The proposed model was able to discriminate potable and contaminated samples containing lead(II), copper(II), zinc(II) and nitrite species. Efforts to reduce the analysis cost have also focused on the development of sensors using low-cost materials. A proposed voltammetric device fabricated with paper, graphite and wax was able to quantify heavy metals and pesticides. The use of a sound agitation system for the portable voltammetric devices resulted in a significant increase in the sensitivity allowing the quantification of lead(II) above 48 nmol L-1, cadmium(II) above 370 nmol L-1 e and zinc(II) above 340 nmol L-1 . Another voltammetric sensor was made for the first time using only cardboard as material and a CO2 laser to pyrolyze the cardboard surface generating conductive carbon structures. Paper colorimetric sensors were successfully tested for fluoride quantification in spring water samples based on photographs taken by a smartphone with a LOQ of 500 µmol L-1. Another paper colorimetric system was capable to measure the pH of samples using a multivariate calibration method. As shown in this thesis, the development and integration of analytical paper-based devices is a reliable and low-cost alternative for water quality analysis
|
58 |
Desenvolvimento de sensores eletroquímicos e colorimétricos para aplicações em amostras de interesse forense / Development of electrochemical and colorimetric sensors for application in forensic interest samplesWilliam Reis de Araujo 07 June 2016 (has links)
Esta tese apresenta os estudos e esforços visando ao desenvolvimento de sensores químicos para aplicações diversas na área forense. Foram desenvolvidos métodos eletroanalíticos para detecção e quantificação de alguns compostos comumente encontrados na adulteração de amostras de drogas de abuso (procaína, fenacetina, aminopirina, paracetamol, levamisol), além da cocaína e estudos fundamentais sobre o comportamento eletroquímico desses compostos. Empregaram-se também métodos eletroquímicos para quantificação de compostos tóxicos e perigosos como explosivos (ácido pícrico) e melamina por exemplo. Os trabalhos utilizando sensores eletroquímicos contemplam modificações eletroquímicas das superfícies eletródicas, utilização de sensores com polímeros molecularmentes impressos (MIP) e eletrodos descartáveis em papel utilizando diferentes técnicas voltamétricas e amperométricas, eletrodo disco rotatório (EDR) e microbalança de cristal de quartzo. Além da fabricação de dispositivos analíticos descartáveis em papel empregando detecção eletroquímica utilizou-se também a detecção colorimétrica para quantificação de alguns dos principais adulterantes de amostras de apreensão de cocaína, como procaína e fenacetina, bem como análises e discriminações de compostos explosivos (peroxi e nitro compostos) nessas plataformas portáteis e de baixo custo. Os métodos foram sempre desenvolvidos visando característicos como: facilidade, praticidade, baixo custo e portabilidade para análises diretamente no local de medida com mínima infraestrutura laboratorial. Por fim, são apresentados alguns estudos realizados durante estágio de pesquisa no exterior (Universidade da Califórnia - San Diego (UCSD)) na área de Wearable Sensors, em que foram desenvolvidos métodos para análises de micronutrientes no suor (zinco) e um metabólito (ácido úrico) na saliva usando sensores aplicados diretamente no corpo humano. / This thesis shows studies and efforts to the development of chemical sensors for different applications in the forensic field. Electroanalytical methods were developed for detection and quantification of some compounds (procaine, phenacetin, aminopyrine, acetaminophen, levamisole) commonly found in the drug of abuse adulteration process and cocaine, as well as, fundamental studies about the electrochemical behavior of these compounds. It was also employed electrochemical methods for quantification of hazardous compounds such as explosives (picric acid) and melamine. Analytical methods with electrochemical sensors included electrochemical modification of electrodic surfaces, molecularly imprinted polymers (MIP), and paper disposable electrochemical devices using different voltammetric and amperometric techniques, rotating disc electrode (RDE) and quartz crystal microbalance. In addition to the fabrication of paper disposable analytical devices with electrochemical detection, it was also used the colorimetric detection to quantify some of the major adulterants in cocaine seizure samples, such as procaine and phenacetin, as well as analysis and discrimination of explosive compounds (peroxy and nitro explosives) in these low cost portable platforms. All proposed methods were always developed aming at theses characteristics: ease, convenience, low cost and portability for analysis directly at the measurement site with minimal laboratory infrastructure. Finally, we presented some studies conducted during research internship abroad (University of California - San Diego (UCSD)) in the area of Wearable Sensors, which have been developed methods for micronutrient analysis in sweat (Zn) and a metabolite (Uric Acid) in saliva using sensors applied directly to the human body
|
59 |
Funcionalização de celulose para ensaios bioanalíticos em dispositivos microfluídicos baseados em papel (μPADs) / Cellulose modification for bioanalytical assays on paper-based microfluidic devices (µPADs)Giorgio Gianini Morbioli 09 June 2015 (has links)
A funcionalização da matriz celulósica é um ponto essencial para o aprimoramento dos dispositivos microfluídicos baseados em papel (µPADs). Ela permite minimizar o preparo de amostras e a interferência do usuário, principais fontes de erro no processo analítico. A oxidação da celulose durante uma hora com m-periodato de sódio e a imobilização química de enzimas a partir da formação de bases de Schiff (iminas), via a adição direta da enzima ao substrato oxidado sem a necessidade de outras etapas, é um processo rápido e de baixo custo, apresentando grande potencialidade de aplicação nos dispositivos microfluídicos em papel. A enzima glicose oxidase imobilizada na celulose, com a adição do estabilizante trealose, apresentou elevada atividade catalítica - de 31,9 ± 5,5 mmol L-1 para a enzima não imobilizada a 14,8 ± 2,0 mmol L-1 para a enzima imobilizada e com o estabilizante - além de apresentar maior homogeneidade de sinal, condições desejáveis em testes rápidos em papel. A confecção de dispositivos em papel via impressão em cera alia rapidez e baixo custo de produção, e o arranjo em camadas para originar dispositivos tridimensionais (3D) permite ampliar as funcionalidades dos dispositivos em duas dimensões, tal como o tratamento individualizado de camadas e o armazenamento de reagentes no próprio dispositivo. O método da adição de padrão para obtenção de curvas analíticas no próprio microchip em papel surge como alternativa às curvas analíticas externas, minimizando a manipulação e o preparo de amostras. O uso do ácido 2,2’-azino-bis (3-etilbenzotiazolina-6-sulfônico) - ABTS como indicador redox para as reações enzimáticas e o método de adição de padrão nos µPADs apresentou boa correlação com um modelo de crescimento e saturação de Michaelis-Menten (r2 = 0,8723) na faixa de 0 a 10 mmol L-1, e a utilização da faixa linear para quantificação de glicose (0 a 3 mmol L-1) apresentou grande correlação linear com a concentração estimada pelas curvas de adição de padrão (r2 = 0,959), demonstrando a potencialidade do método. A união da tecnologia desses dispositivos em papel com a de um software automatizado de reconhecimento de imagens (PAlizer) torna instantânea a obtenção de resultados, eliminando-se a necessidade de intervenção humana no processo, tornando os testes em papel mais robustos, reprodutíveis e rápidos. Com o contínuo aperfeiçoamento das funcionalidades e potencialidades dos dispositivos microfluídicos em papel espera-se que os testes diagnósticos de baixo custo atinjam àqueles que deles necessitam, contribuindo para a saúde da população. / Functionalization of a cellulosic matrix is essential for the success of the paper-based microfluidic analytical devices (µPADs). It allows minimization of sample preparation and user interference, both being major sources of errors in the analytical process. Cellulose oxidation with sodium m-periodate during one hour and the direct chemical immobilization of enzymes on it by Schiff-base (imines) formation, which is made by direct insertion of the enzyme on the oxidized substrate without subsequent steps, is a fast and low cost process of immobilization, presenting great potential of application in paper-based microfluidic analytical devices. The glucose oxidase enzyme immobilized on cellulose, with the addition of trehalose stabilizer presented enhanced catalytic activity - from 31.9 ± 5.5 mmol L-1 for the non-immobilized enzyme to 14.8 ± 2.0 mmol L-1 for the immobilized enzyme with the stabilizing agent - also presenting greater signal homogeneity, which are ideal characteristics in a paper-based rapid test. Wax printing is a simple, inexpensive and fast method by which micro-devices can be fabricated. Additionally, the stacking of layers originating tridimensional devices (3D) allow for the improvement of functionalities of 2-dimensional ones, such as individualized layer treatment and reagent storage at different layers in the same device. Standard addition to analytical curves in paper-based microchips is an alternative to external analytical curves, minimizing handling/sample preparation. The use of 2,2\'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid - ABTS redox indicator with the enzymatic reactions and the standard addition method in µPADs presented a good correlation in a growth and saturation Michaelis-Menten model (r2 = 0.8723), in the range of 0 to 10 mmol L-1, and the usage of the linear range to the glucose quantification (0 to 3 mmol L-1) presented a high linear correlation with the estimated concentration from the standard addition curves (r2 = 0.959), showing the potentiality of the method. The coupling of such paper-based devices to automated image analysis software, such as \'PAlizer\', turns the data acquisition process instantaneous, eliminating the need of human intervention during the process, making it more robust, reproducible and rapid. Expectations lie in improving the devices functions and potential so that these low-cost diagnostic devices can one day reach those who need them, contributing significantly to public health.
|
60 |
The Effect of GED Candidate Race and Motivation Factors on Exam OutcomesMiddleton, Kathi L. 01 January 2017 (has links)
Earning a General Educational Development (GED) credential can have positive results in a student's life including higher wages and better job opportunities. The 2014 version of the GED exam changed the format from a paper-based test to a computer-based test. This change coincided with a 35% decline in the pass rate indicating not all students are prepared to pass the new computer-based test (CBT). The purpose of this quantitative study was to evaluate the influence of a candidate's race and reason for taking the exam on the pass or fail outcome of the new computer-based GED exam. The study used Vroom's expectancy theory as the theoretical framework. The guiding question was to examine the relationship between a candidate's motivation and pass or fail outcome of the CBT. This study used a quantitative approach to analyze available archival data from The Technical College System of Georgia in 2014 and 2015. Two chi-square analyses were conducted on data from 21,641 participants using candidate's race, reason for taking the exam, and GED pass or fail outcome. Results suggested that individually, both a candidate's race and reason for taking the test have a statistically significant effect on the participant's pass or fail outcome. Results from this study may help GED educators and students better understand factors that can influence student success. Integrating career development orientations and remedial computer based technology classes into the GED preparation process were recommended. Implications for positive social change include the potential to increase student motivation, improve the preparedness of both students and educators and subsequently increase the number of people who pass the GED exam.
|
Page generated in 0.0481 seconds