• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização fluidodinâmica e térmica de jatos sintéticos

Lehnen, Matheus Vicenzo 05 1900 (has links)
Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2015-07-08T14:34:31Z No. of bitstreams: 1 Matheus Vicenzo Lehnen.pdf: 7507080 bytes, checksum: 1036a30adcb3840ea0e5fcb545f29987 (MD5) / Made available in DSpace on 2015-07-08T14:34:31Z (GMT). No. of bitstreams: 1 Matheus Vicenzo Lehnen.pdf: 7507080 bytes, checksum: 1036a30adcb3840ea0e5fcb545f29987 (MD5) Previous issue date: 2012-05 / Milton Valente / Nos dias atuais, os componentes eletrônicos estão cada vez mais potentes e com mais dispositivos integrados e há a necessidade de uma dissipação térmica mais eficiente. Os atuais ventiladores e dissipadores de calor usando ar como fluido de trabalho estão ficando obsoletos. Por este motivo, torna-se necessário o desenvolvimento de um sistema mais eficiente. Existem três técnicas principais em estudo nesta área: resfriamento líquido, trocadores de calor compostos por microcanais e jatos sintéticos como transmissores de quantidade de movimento ao fluido. Entretanto, a análise em pequena escala encontra limitações experimentais de modo que uma abordagem por Dinamica de Fluidos Computacional (Computational Fluid Dynamics – CFD) é mais recomendável para caracterizar e validar o desempenho dos jatos sintéticos. O objetivo principal deste trabalho é realizar uma análise fluidodinâmica de jatos sintéticos e caracterizar a troca térmica de jatos sintéticos colidindo sobre uma superfície aquecida, através de simulação numérica. A flexibilidade da aproximação numérica também possibilita o estudo da sensibilidade do design a vários parâmetros físicos e geométricos, tais como o número de Reynolds, a frequência do atuador, o número de Prandtl, a distância da placa aquecida ao orifício da cavidade, o formato do orifício do atuador, a profundidade da cavidade e a espessura da placa do orifício. Os resultados caracterizam o efeito dos parâmetros físicos e geométricos de interesse na formação do jato e na dissipação térmica. O conhecimento agregado neste estudo permitiu determinar uma correlação para o número de Nusselt em função da frequência adimensional – o número de Strouhal – do número de Reynolds, do número de Prandtl e da distância adimensional da superfície aquecida ao orifício. Assim, é possível prever o comportamento de tais jatos sobre a superfície aquecida, e assim contribuir para os atuais estudos nesta linha de pesquisa. Os resultados apresentados tem então aplicação em estudos posteriores, de maior complexidade de design com atuadores combinados com trocadores de calor de aletas, coolers e micro canais, resultando em avanços na área de resfriamento de microchips. / Current electronic components are becoming ever more potent and densly integrated, which requires further increases in the efficiency of heat dissipation. With current fan-based heat dissipation techniques with air as the working fluid becoming outdated, there is a pressing need to develop more eficient methods to cope with demand. So far, three techniques have been the primary focus of studies in this area: liquid cooling, microchannel heat exchangers and synthetic jets used to promote increased momentum transfer. Analysis of such devices at the small physical scale of electronic components is somewhat problematic in experimental form so that a computational fluid dynamics (CFD) approach is recommended. The main objective of this study is thus to utilize a CFD approach to establish the performance characteristics of a synthetic jet impacting against a heated surface. The flexibility of a numerical approach also allows the examination of the sensibility of the design with respect to several physycal and geometric parameters such as Reynolds number, pulsing frequency, jet orifice shape and size, cavity size and distance between the heated surface and the device. Such results, provide insight in the effect of physical and geometric parameters in the jet formation and heat dissipation. The combined knowledge of this study allowed the development of a practical correlation for the Nusselt number based on the Strouhal number (normalized pulsing frequency), Reynolds number, Prandtl number and the distance between the heated surface and the synthetic jet. This result allows improved predictions of a jet impacting against a heated surface and, consequently, adds an important contribution to other studies in this area. It is expected that the results presented here will be the starting point for further work, in which increasingly complex geometries such as actuators combined with heat exchangers equipped with fins, coolers or microchannels are examined to further improve the knowledge in the field of electronic cooling.
2

Estudo da ligação viga-pilar em sistema estrutural de concreto considerando a variação da semi-rigidez por meio de parâmetros geométricos da ligação / Study of beam-column connection in structural concrete system considering the variation of semi-rigidity through geometric parameters of the connection

Araújo, Tássio Jorge Figueiredo de 26 July 2013 (has links)
This work presents a study to quantify the influence of geometrical and stiffness parameters on the behavior of beam-column concrete connections. Therefore, linear elastic models are designed by using three-dimensional finite elements in the commercial software Abaqus. These models serve as a reference for the optimization of geometrical and rigidity parameters of reticulated models, which are commonly used in structural projects. The results confirm some tendencies of influence by parameters already reported in the literature, such as variations in stiffness caused by eccentricity and width variations. The results indicate variations in vertical displacement of the beams up to 5%, maintaining the vertical load and varying only the eccentricity and up to 60% only by varying the widths of the elements. Furthermore, the use of punctual representations of semi-rigidity on monolithic concrete connections through rotational springs is discarded, proving necessary an improvement of the model to represent the behavior of the connection. Several models have been proposed and tested in the representation of the semi-rigid behavior of the connections, making use of rigid core, rotational springs and variations of inertia and area. / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este trabalho apresenta um estudo de quantificação da influência de parâmetros geométricos e de rigidez no comportamento de ligações viga-pilar de concreto. Para tanto, são concebidos modelos elásticos lineares de ligação em elementos finitos tridimensionais utilizando o programa comercial Abaqus. Esses modelos servem como referência para a otimização dos parâmetros geométricos e de rigidez de modelos reticulados, que são os comumente utilizados em projetos estruturais. Os resultados obtidos confirmam algumas tendências de influência de parâmetros já apresentados na literatura, como variações de rigidez causadas por excentricidade e variações de largura. Os resultados indicam variações de deslocamento vertical nas vigas de até 5%, mantendo-se a carga vertical e variando apenas a excentricidade, e de até 60% variando-se apenas as larguras dos elementos. Além disso, é descartada a utilização de representações pontuais da semi-rigidez em ligações monolíticas de concreto através de molas rotacionais, provando ser necessário um aprimoramento do modelo para a representação do comportamento da ligação. Diversos modelos de barra são propostos e testados na representação do comportamento semi-rígido das ligações, fazendo uso de núcleos rígidos, molas rotacionais e variações de inércia e área.

Page generated in 0.074 seconds