Power Electronic Control of a Partial Core Transformer

Bendre, Vijay January 2010 (has links)
The research programme at the University of Canterbury includes the development and applications of partial core inductors and transformers for high voltage testing of generator insulation. Unlike a conventional full core transformer, a partial core transformer has no limbs and yokes. A partial core transformer is a compromise between a full core and coreless transformer. It is superior to its full core counterpart as far as cost, weight and ease of transportation are concerned. Partial core transformers have a low magnetising reactance and hence draw a high magnetising current. This characteristic makes them a perfect fit in applications where the load is capacitive in nature, such as a.c. power frequency high voltage testing of generator insulation and cable testing etc. The work carried out for this thesis focuses on automatically controlling the amount of reactive power on the supply side of a partial core transformer. The considered design includes a third winding around the existing two windings. A power electronic controller is connected to the third winding, which modifies the VAr absorption characteristics of the magnetically coupled supply winding. Two options are considered to achieve continuous reactive power control in the partial core transformer as explained below. First, a thyristor controlled reactor (TCR) is proposed as the VAr controller. It is modelled using PSCAD/EMTDC software. Simulations reveal the design criteria, overall performance and the limitations of the suggested proposal. The TCR connected tertiary winding takes the capacitive burden of the supply. The model demonstrates the ability of the automatically controlled TCR to provide a continuous variation of reactive power without significant under or over compensation. This feature limits the supply current to its real component only, so the supply provides only the losses of the system. Second, a voltage source converter is considered as the VAr controller. This is modelled in PSCAD/EMTDC and a hardware prototype is designed and built. Based on the analysis, the control algorithm (including a digital PI controller) is implemented using an 8 bit micro-controller, PIC18LF4680. The prototype is tested in the laboratory for both active and inductive load conditions as seen from the supply side. Performance of the hardware prototype is discussed in detail. The PSCAD/EMTDC model and the hardware prototype successfully demonstrate the feasibility of a STATCOM controlled partial core transformer. The proposed system is capable of compensating a wide range of capacitive loads as compared with its TCR counterpart. It is proved that the system is very robust and remains dynamically stable for a large system disturbance such as change in load from full capacitive to inductive and vice versa. This confirms that the system is capable of providing continuous VAr control.
2

High Temperature Superconducting Partial Core Transformers

Lapthorn, Andrew Craig January 2012 (has links)
The thesis begins by providing an introduction to transformer theory. An ideal transformer is examined first, followed by full core transformer theory. The partial core transformer is then introduced and compared to the full core design. An introduction to superconductors is then presented where a simplified theory of superconductivity is given. High temperature superconductors are then examined including their physical structure, superconducting properties and the design of the superconducting wire. The early development of high temperature superconducting partial core transformers at the University of Canterbury is then examined. Early partial core development is discussed followed by some material testing at cryogenic temperatures. This work lead into the development of the first high temperature superconducting partial core transformer. This transformer failed during testing and an examination of the failure mechanisms is presented. The results of the failure investigation prompted an alternative winding insulation design which was implemented in a full core superconducting transformer. The modelling used to design a high temperature superconducting partial core transformer is then presented. Based upon the reverse design method, the modelling is used to determine the components of the Steinmetz equivalent transformer circuit. The modelling includes a combination of circuit theory and finite element analysis. An ac loss model for high temperature superconductors is also presented. A new 15 kVA, 230-230V high temperature superconducting partial core transformer was designed, built and tested. The windings are layer wound with first generation Bi2223 high temperature superconductor. The modelling was used to predict the performance of the transformer as well as the ac losses of the high temperature superconductor. A series of electrical tests were performed on the transformer including open circuit, short circuit, resistive load, overload, ac withstand voltage and fault ride through tests. The test results are compared with the model. The transformer was found to be 98.2% efficient at rated power with 2.86% voltage regulation.
3

High-voltage partial-core resonant transformers

Bell, Simon Colin January 2008 (has links)
This thesis first describes the reverse method of transformer design. An existing magnetic model for full-core shell-type transformers, based on circuit theory, is summarised. A magneto-static finite element model is introduced and two sample transformers are analysed. The magnetic model based on finite element analysis is shown to be more accurate than the model based on circuit theory. Partial-core resonant transformers are then introduced and their characteristics are explained using an equivalent circuit model. A method of measuring the winding inductances under resonant operation is developed and used to investigate the characteristics of two different tuning methods. A finite element model of the partial-core resonant transformer is developed by adopting the model for full-core shell-type transformers. The model results accurately match the measured inductance variation characteristics of three sample transformers and predict the onset of core saturation in both axial-offset and centre-gap arrangements. A new design of partial-core resonant transformer is arrived at, having an alternative core and winding layout, as well as multiple winding taps. The finite element model is extended to accommodate the new design and a framework of analysis tools is developed. A general design methodology for partial-core resonant transformers with fixed inductance is developed. A multiple design method is applied to obtain an optimal design for a given set of specifications and restrictions. The design methodology is then extended to devices with variable inductance. Three design examples of partial-core resonant transformers with variable inductance are presented. In the first two design examples, existing devices are replaced. The new transformer designs are significantly lighter and the saturation effects are removed. The third design example is a kitset for high-voltage testing, with the capability to test any hydro-generator stator in New Zealand. The kitset is built and tested in the laboratory, demonstrating design capability. Other significant test results, for which no models have yet been developed, are also presented. Heating effects in the core are reduced by adopting an alternative core construction method, where the laminations are stacked radially, rather than in the usual parallel direction. The new kitset is yet to be used in the field.
4

New Model of Eddy Current Loss Calculation and Applications for Partial Core Transformers

Huo, Xi Ting (Bob) January 2009 (has links)
This thesis first explains the eddy current and the phenomenon of skin effect, where the resultant flux flows near the surface of the metal. A new flux direction perspective is created for steel laminations, from which derivations of the eddy current resistance and power losses in different directions are developed assuming uniform flux conditions. The developed method compares with a proposed theory through experimental data. The results from the comparison support the validity of the developed derivations. Two uniform flux generators and their billets construction are introduced. The power loss between two cubic billets with different orientations is compared. A Finite Element Analysis (FEA) program is used to show the difference between lamination alignments. To prove the validity of the developed theory, two experiments were performed using two different electroheating apparatus. The results give scale factors from which the theoretical values can be matched to the experimental ones. Due to the poorer construction of the first apparatus, the scale factor of measured to computed losses is 1.15. The scale factor for the second apparatus can be taken as unity, revealing a good match between theory and measurements. After verification of the developed equations for uniform flux experiments, the focus of the eddy current loss calculation turned to partial core transformers. The flux background of a cubical core is reviewed. Three key factors ( L', Kec and βa) are introduced into the eddy current power loss model. L' is a length which indicates the region of the flux spreading at the ends of the core. Kec as a ratio indicates how much of the main flux spreads at the ends of the core. βa is the ratio of the winding axial length and winding thickness. Using simulations from the Finite Element Analysis (FEA) program MagNet, a partial core side view with the flux distribution and flux density from two orthogonal angles is created. A flux linkage comparison between the experimental results and the returned values from MagNet verifies the high accuracy of the flux plot in MagNet. The eddy current power loss model is then built up with equations. The relationships amongst the three key factors are studied and confirmed using the experimental results. Normally, a partial core transformer uses a cylindrical partial core rather than a cubical partial core, to reduce the amount of winding material. Therefore, a further goal was to prove the developed model for cylindrical partial core transformers. The construction differences between the cubical and cylindrical core is discussed. The orthogonal flux assumptions for the cylindrical core in two directions are reviewed. The flux penetration between two adjacent blocks is considered and explained. The mathematical core loss model is created for a cylindrical core composing by ten blocks. Three tests were performed using the developed core loss model. The results visualize the power loss from the core by its temperature distribution, and consequently prove the validity of the developed core loss model. An eddy current loss comparison and the discussion are made between the previous method and the developed method. Overall, the results confirm a significant improvement using the developed core loss model, and a generic form of the partial core can be used for designing future models of partial core transformers which have a stacking factor greater than 0.96.
5

High Temperature Superconducting Partial Core Transformer and Fault Current Limiter

Sham,Jit Kumar January 2015 (has links)
The thesis begins with an introduction to transformer theory. The partial core transformer is then introduced and compared with a full core design. A brief introduction to superconductors and high temperature superconductors is then presented. High temperature superconducting fault current limiters are then examined and the advantage of a high temperature superconducting partial core transformer and fault current limiter as a single unit is highlighted. The reverse design model is discussed followed by the model parameters that are used in designing the high temperature superconducting partial core transformer. Partial core transformers with copper windings and high temperature superconductor windings at the University of Canterbury were then tested and the measured results compared with the results calculated from the reverse design model, to validate the model. The high temperature superconducting partial core transformer failed during an endurance run and the investigation of the failure is then presented. The results of the failure investigation prompted an alternative winding insulation design. A model to calculate the time at which the high temperature superconducting winding of the partial core transformer would melt at different currents was then built. The time was calculated to be used in the operation of the quench detection mechanism and it could also be used in choosing a circuit breaker with a known operating time. The design of the high temperature superconducting partial core transformer and fault current limiter is then presented. Design configurations with different core length and winding length are examined. The idea behind choosing the final design for the high temperature superconducting partial core transformer and fault current limiter is then discussed. The final design of the high temperature superconducting partial core transformer and fault current limiter is then presented. A new 7.5 kVA, 230-248 V high temperature superconducting partial core transformer and fault current limiter was designed, built and tested. The windings are layer wound with first generation Bi2223 high temperature superconductor. A series of electrical tests were performed on the new device including open circuit, short circuit, resistive load, overload and fault ride through. These tests were performed to determine the operational characteristics of the new high temperature superconducting partial core transformer and fault current limiter. The measured results from the tests were compared with the calculated results. The fault ride through test results were then compared to a 15 kVA high temperature superconducting partial core transformer that was designed and built at the University of Canterbury. Since the resistive component of the silver matrix in Bi2223 high temperature superconductor plays a very little role in controlling the fault current, the current limited by the leakage reactance is compared between the two devices. The high temperature superconducting partial core transformer and fault current limiter was found to be 99.1% efficient at rated power with 5.7% regulation and fault current limiting ability of 500 % over the 15 kVA high temperature superconductor partial core transformer from University of Canterbury.