• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 13
  • 9
  • 1
  • Tagged with
  • 63
  • 63
  • 31
  • 31
  • 29
  • 12
  • 11
  • 9
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Three-dimensional photoelastic stress analysis of a bilateral distal-extension mandibular removable partial denture with mesial and distal occlusal rests a thesis submitted in partial fulfillment ... denture prosthodontics ... /

Ko, Seok-Hoon. January 1983 (has links)
Thesis (M.S.)--University of Michigan, 1983.
22

Three-dimensional photoelastic stress analysis of a bilateral distal-extension mandibular removable partial denture with mesial and distal occlusal rests a thesis submitted in partial fulfillment ... denture prosthodontics ... /

Ko, Seok-Hoon. January 1983 (has links)
Thesis (M.S.)--University of Michigan, 1983.
23

The changes of contour which occur during the repair of heat-cured and self-cured maxillary dentures a dissertation submitted in partial fulfillment ... in dental materials ... /

Anthony, David H. January 1961 (has links)
Thesis (M.S.)--University of Michigan, 1961.
24

Comparison of occlusal rest seat preparations to cast metal rests.

Cassim, Shabir. January 2007 (has links)
<p>A well designed metal-based removable partial denture (MBRPD) is a cost-effective and a conservative method of rehabilitating a partially edentulous mouth. The MBRPD demands that the abbutment tooth provides support and/or retention while the abutment tooth, in turn, expects the MBRPD to transmit the forces axially and to be passive when fully seated. For vertical forces to be transmitted axially, occlusal rest seats have to be prepared on the abutment teeth to receive a cast metal rest of the MBRPD. The&nbsp / objective of this study was to compare occlusal rest seat preparations for metal-based removable partial dentures (MBPRD) prepared by dental students at the UWC Oral Health centres, to the corresponding cast metal rests and to determine action taken in response to discovered discrepancies between the rest seat preparation depth and the cast metal occlusal rset thickness.</p>
25

An in vitro analysis of the behaviour of an alumina based dental all-ceramic restorative system subjected to occlusal loads

Ironside, James G January 2001 (has links)
Doctor of Philosophy / The commercial introduction of glass infiltrated slip cast ceramic technology as a core dental ceramic for crowns and bridges began in 1990. The system known as Inceram® provided a metal free ceramic core with a flexural strength that was reported to be between 400 and 600 MPa. The first aim of this study was to investigate in vitro fractures for this type of crown that occurred from high localized occlusal loading. The second aim was to propose suitable guidelines for the construction of crowns that are more crack resistant when loaded by a spherical object such as an opposinc cusp. The review of the literature identified Young’s modulus (E) as an important aspect for the behaviour of a brittle solid when it is exposed to load. Young’s modulus is involved in the total energy of the solid, its free surface energy, its toughness, parameters involved in contact areas, stresses from indenters on those contact areas and at the interface between two materials with different moduli. This mismatch was to become more important when Finite Element Analysis was applied to the test results. A second physical property that has importance in bilaminar minerals is Poisson’s ratio. Less important than Young’s modulus, Poisson’s ratio still provides some of the answers to crack propagation at an interface, highlighted by the description of Dundurs parameters (Mencik 1996). The use of Weibull statistics provided information concerning reliability for different core to veneer thickness ratios in the experimental models and crown designs. The first experimental part was to establish a crown model suitable for investigation. The porcelain jacked crown restoration for an upper incisor was chosen because it provided the best opportunity to vary the construction parameters of the crown without sacrificing the aesthetics. The results from this initial in vitro study established thickness ranges for the standard design of these crowns, the loads that could be expected and the two types of fracture patterns that might occur when the bilaminar system is loaded via a hard steel ball indenter in the middle of the palatal surface. The data from chapter three were then compared with two basic bilaminar and monolithic disc designs to establish the relevance of the dimensions of the ISO standard test specimen design for flexural strength. The results of this chapter confirmed that the loads were in the same range for the bilaminate discs, and that the flexural strengths for the two component parts were in agreement with other known results. The use of Finite Element Analysis (FEA) was employed to provide an additional method for testing the model to establish areas when principal stresses might lie and how they were distributed. It was found that the ISO flexural strength test was not ideal for testing bilaminates because it did not account for the large mismatch in Young’s modulus between the two component materials. The FEA revealed an unexpected increase in tensile stress on the bottom surface of the In-Ceram when it was the bottom layer in the bilaminate. The FEA did confirm the difference between a flat punch and a ball indenter for stress intensities around the contact area with the ball indenter producing higher stresses for a given load…
26

Comparison of occlusal rest seat preparations to cast metal rests.

Cassim, Shabir. January 2007 (has links)
<p>A well designed metal-based removable partial denture (MBRPD) is a cost-effective and a conservative method of rehabilitating a partially edentulous mouth. The MBRPD demands that the abbutment tooth provides support and/or retention while the abutment tooth, in turn, expects the MBRPD to transmit the forces axially and to be passive when fully seated. For vertical forces to be transmitted axially, occlusal rest seats have to be prepared on the abutment teeth to receive a cast metal rest of the MBRPD. The&nbsp / objective of this study was to compare occlusal rest seat preparations for metal-based removable partial dentures (MBPRD) prepared by dental students at the UWC Oral Health centres, to the corresponding cast metal rests and to determine action taken in response to discovered discrepancies between the rest seat preparation depth and the cast metal occlusal rset thickness.</p>
27

An in vitro analysis of the behaviour of an alumina based dental all-ceramic restorative system subjected to occlusal loads

Ironside, James G January 2001 (has links)
Doctor of Philosophy / The commercial introduction of glass infiltrated slip cast ceramic technology as a core dental ceramic for crowns and bridges began in 1990. The system known as Inceram® provided a metal free ceramic core with a flexural strength that was reported to be between 400 and 600 MPa. The first aim of this study was to investigate in vitro fractures for this type of crown that occurred from high localized occlusal loading. The second aim was to propose suitable guidelines for the construction of crowns that are more crack resistant when loaded by a spherical object such as an opposinc cusp. The review of the literature identified Young’s modulus (E) as an important aspect for the behaviour of a brittle solid when it is exposed to load. Young’s modulus is involved in the total energy of the solid, its free surface energy, its toughness, parameters involved in contact areas, stresses from indenters on those contact areas and at the interface between two materials with different moduli. This mismatch was to become more important when Finite Element Analysis was applied to the test results. A second physical property that has importance in bilaminar minerals is Poisson’s ratio. Less important than Young’s modulus, Poisson’s ratio still provides some of the answers to crack propagation at an interface, highlighted by the description of Dundurs parameters (Mencik 1996). The use of Weibull statistics provided information concerning reliability for different core to veneer thickness ratios in the experimental models and crown designs. The first experimental part was to establish a crown model suitable for investigation. The porcelain jacked crown restoration for an upper incisor was chosen because it provided the best opportunity to vary the construction parameters of the crown without sacrificing the aesthetics. The results from this initial in vitro study established thickness ranges for the standard design of these crowns, the loads that could be expected and the two types of fracture patterns that might occur when the bilaminar system is loaded via a hard steel ball indenter in the middle of the palatal surface. The data from chapter three were then compared with two basic bilaminar and monolithic disc designs to establish the relevance of the dimensions of the ISO standard test specimen design for flexural strength. The results of this chapter confirmed that the loads were in the same range for the bilaminate discs, and that the flexural strengths for the two component parts were in agreement with other known results. The use of Finite Element Analysis (FEA) was employed to provide an additional method for testing the model to establish areas when principal stresses might lie and how they were distributed. It was found that the ISO flexural strength test was not ideal for testing bilaminates because it did not account for the large mismatch in Young’s modulus between the two component materials. The FEA revealed an unexpected increase in tensile stress on the bottom surface of the In-Ceram when it was the bottom layer in the bilaminate. The FEA did confirm the difference between a flat punch and a ball indenter for stress intensities around the contact area with the ball indenter producing higher stresses for a given load…
28

Plaque formation and gingival inflammation as influenced by the lingual bar position of the mandibular removable partial denture a thesis submitted in partial fulfillment ... in denture prosthodontics ... /

Adams, Mark W. January 1900 (has links)
Thesis (M.S.)--University of Michigan, 1986.
29

Force transmission by the indirect retainer during unilateral loading a thesis submitted in partial fulfillment ... denture prosthodontics ... /

McDowell, Glen C. January 1977 (has links)
Thesis (M.S.)--University of Michigan, 1977.
30

Treatment outcomes of patients with implant-supported fixed partial prostheses

Wyatt, Chris, January 1996 (has links)
Thesis (M. Sc.)--University of Toronto, 1996. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.

Page generated in 0.3269 seconds