• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 13
  • 9
  • 1
  • Tagged with
  • 63
  • 63
  • 31
  • 31
  • 29
  • 12
  • 11
  • 9
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Analise fotoelastica da distribuição de tensões induzidas por infra-estruturas implanto-suportadas obtidas pelas tecnicas do cilindro cimentado e soldado a laser / Stress distribution by implant-retained prosthesis comparing cylinders cemented and laser-welded.

Kleine, Alessandra 31 March 2006 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T10:58:33Z (GMT). No. of bitstreams: 1 Kleine_Alessandra_D.pdf: 1218745 bytes, checksum: c3583b924be9dcbd0a46d894fa1e9196 (MD5) Previous issue date: 2006 / Resumo: Este estudo avaliou a distribuição de tensões, através da análise fotoelástica de infra-estruturas de próteses fixas implanto-suportadas, confeccionadas pelas técnicas do cilindro cimentado ou soldado a laser. As estruturas foram obtidas a partir de uma matriz metálica com formas e dimensões similares a um arco mandibular. Foram confeccionadas 6 estruturas metálicas fundidas em titânio comercialmente puro (TritanÒ¿ Dentaurum - Germany), divididas em dois grupos: Grupo I: cilindros cimentados com cimento resinoso (Panavia FÒ Kuraray Co- Japan) e Grupo II: cilindros soldados a laser. Foram feitas mensurações com auxílio de um microscópio mensurador, com precisão de 0,0005 mm (STM Digital ¿ Olympus ¿ Japan), através do teste do parafuso único. Foi, então, escolhida a estrutura melhor adaptada, para cada um dos grupos, para a realização da análise fotoelástica, que foi realizada sobre um modelo confeccionado em resina fotoelástica (Aralditeâ GY279BR Huntsman - Araltec Produtos Químicos Ltda. ¿ Guarulhos - São Paulo), utilizando três seqüências de aperto dos parafusos (1/2/3/4/5, 5/4/3/2/1 e 3/2/4/1/5). Os resultados indicaram que maior quantidade de tensões foi observada na seqüência de aperto 1/2/3/4/5, para os grupos analisados. O grupo dos cilindros cimentados mostrou os melhores resultados, com menores valores de desadaptação (43,95 e 22,07mm) quando comparado ao grupo dos cilindros soldados a laser (198,8 e 60,17mm). A seqüência de aperto 3/2/4/1/5 mostrou menor quantidade de tensões para o grupo dos cilindros cimentados. A seqüência 5/4/3/2/1 apresentou melhores resultados para o grupo dos cilindros soldados a laser. O grupo dos cilindros cimentados apresentou melhores resultados, associado à seqüência 3/2/4/1/5 / Abstract: The aim of this study was to evaluate, by means of photoelastic analysis, the passive fit of fixed implant-supported prosthesis titanium frameworks using the cemented cylinder or laser welded cylinder techniques. Six frameworks welded in commercially pure titanium (TritanÒ-Dentaurum, Pforzhein-Germany) were made in a metallic master cast and divided in two groups. Group I: cylinders cemented with anaerobe resin (Panavia FÒ - Kuraray Co.) and Group II: cylinders laser-welded. The interfaces¿ evaluation and measurements were performed using a measurer microscope (STM Digital ¿ Olympus ¿ Japan) with 0.0005mm of precision. Thus, the ill-fit framework, for each group was chosen and evaluated by photoelastic analysis. The photoelastic model was made in photoelastic resin (Aralditeâ GY279BR Huntsman - Araltec Produtos Químicos Ltda. ¿ Guarulhos - Sao Paulo). Both groups were submitted to the photoelastic analysis, testing three screw-tightening sequences (1/2/3/4/5, 5/4/3/2/1 and 3/2/4/1/5). Results showed superior stress in 1/2/3/4/5 sequence of both groups. The cemented cylinder group showed better stress results (43.95 and 22.07mm) compared to the laser-welded cylinder group (198.8 and 60.17mm). The 3/2/4/1/5 sequence presented better stress for the cemented cylinder group. The 5/4/3/2/1 sequence showed better results for the laser-welded cylinder group. The cemented cylinder group presented the best results of stress analysis allied to the 3/2/4/1/5 sequence / Doutorado / Protese Dental / Doutor em Clínica Odontológica
62

Influencia do material de inclusão e apoio da grade metalica na estabilidade de proteses parciais removiveis de extremidade livre durante o processamento das bases polimerizadas por energia de microondas

Zanetti, Glauco Rangel 24 November 2000 (has links)
Orientador: Celia Marisa Rizzatti Barbosa / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T03:15:46Z (GMT). No. of bitstreams: 1 Zanetti_GlaucoRangel_D.pdf: 4522575 bytes, checksum: 4717fe0797e79a21a39c9cbeebb8ac1d (MD5) Previous issue date: 2000 / Resumo: Este estudo avaliou a influência do material de inclusão (gesso tipo 11 Herodent@ "G", silicone por condensação laboratorial Zetalabor@ "Z"), e da configuração da porção distal da grade metálica (com apoio "C" e sem apoio "s" sobre o modelo), nas alterações horizontais (esquerda "HE" e direita "HD") e verticais (esquerda "VE" e direita "VD") , entre as porções distais de estruturas metálicas de prõteses parciais removíveis (PPR's) e seus respectivos modelos durante o processamento das bases em resina acrílica. Foram utilizados modelos simulando uma arcada inferior parcialmente desdentada classe I de Kennedy. Quarenta amostras padronizadas foram divididas em quatro grupos. As bases foram processadas com uma resina polimerizada por energia de microondas (Onda-Cryl@). Os dados foram submetidos à análise de variância e as médias, ao teste de Tukey (p<O,O5). Os resultados das médias das alterações em milímetros, nos grupos GC (HE=0,2043; HD=0,1610; VE=0,0599; VD=0,0599), GS (HE=O,1888; HD=0,1156; VE=0,2063; VD=O,2420), ZC (HE=0,1796; HD=0,2025; VE=O,0717; VD=0,1396), ZS (HE=0,2043; HD=0,O746; VE=O,2143; VD=0,2880) indicaram que: na VE e VD, G não diferiu de Z, mas C apresentou alterações significativamente menores que S; na HE os grupos não diferiram estatisticamente entre si; na HD não houve diferença significativa entre (ZC e GC), (GC e GS), (GS e ZS) e as alterações foram progressivamente maiores em ZS, GS, GC e ZC / Abstract: This study evaluated the effect of two types of investment material ("G", type 11 dental stone, Herodent@; "Z", condensation silicone, Zetalabor@) and two types of design of the distal portion of the metallic framework ("S", with support in the model; "N", without support in the model) in the horizontal ("H L", left; "HR", right) and vertical ('VL", left; 'VR", right) distance changes between the distal portion of the metallic framework and their respective models during processing of the acrylic bases. A lower Kennedy Class I model was used. Forty standardized RPD's were prepared and equally divided into 4 groups. The RPD's bases were processed using a microwave-cured acrylic resin (OndaCryl@). Data was submitted to a "Tukey's Studentized" test (p<O.O5). The results of the means alterations in millimeters, in the groups GS (HL=O.2043; HR=O.1610; VL=O.O599; VR=O.O599), GN (HL=O.1888; HR=O.1156; VL=O.2063; VR=O.2420), ZS (HL=O.1796; HR=O.2025; VL=O.O717; VR=O.1396), ZN (HL=O.2043; HR=O.O746; VL=O.2143; VR=O.2880) showed that for VL and VR measurements, G and Z were not different, and S showed statistical lower changes than N. There was not difference of HL among groups. Considering HR, there was no statistical difference between groups for each following pair: ZS-GS, GS-GN and GN-ZN. Changes were crescent in the order ZN, GN, GS and ZS / Doutorado / Protese Dental / Doutor em Clínica Odontológica
63

Influência do formato do rebordo na associação de uma prótese parcial removível de extremidade livre mandibular associada ao implante com sistema de retenção ERA, pelo método dos elementos finitos /

Lucas, Liliana Vicente Melo de. January 2006 (has links)
Resumo: Associação das próteses parciais removíveis de extremidade livre com os implantes osseointegrados é, ainda, uma opção de tratamento pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão e o deslocamento nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm com sistema ERA de retenção, em diferentes formatos de rebordo alveolar. Para tanto, foram criados oito modelos, os quais, em corte sagital, representam: Modelo A (MA) - uma hemiarcada com rebordo horizontal, sem suporte posterior, com a presença do dente 33 e de uma PPREL convencional, com apoio metálico na incisal do dente 33, em substituição aos dentes 34, 35, 36 e 37; Modelo B (MB) - semelhante ao MA, diferenciando-se deste pela presença de um implante de 3,75 x 10,00 mm com sistema ERA de retenção associado, na região posterior da base da PPREL; Modelo C (MC) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação ascendente distal; Modelo D (MD) - semelhante ao MC, diferenciando-se deste pela presença do implante com sistema de retenção associado; Modelo E (ME) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação descendente distal; Modelo F (MF) - semelhante ao ME, diferenciando-se deste pela presença do implante com sistema ERA de retenção; Modelo G (MG) - semelhante ao MA, entretanto o rebordo distal apresenta formato descendente-ascendente; Modelo H (MH) - semelhante ao MG, diferenciando-se deste pela presença do implante com sistema ERA de retenção. Com o auxílio do programa de elementos finitos ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N, em cada ponta de cúspide....(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The association of mandibular distal extension removable artial dentures with an osteointegrated implant is a treatmeat hasn't been fully explored by modern rehabilitation dentistry yet. For this reason, the objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension and the displacement on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. For that purpose, eight models were created, representing, from a sagittal perspective: Model A (MA) - a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) - similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) - similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) - similar to ME, but different in the sense that there is an implant with an associated ERA retention system; Model G (MG) - similar to MA, however with a distally descending-ascending ridge format; Model H (MH) - similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip...(Complete abstract, click electronic address below) / Orientador: Eduardo Piza Pellizzer / Coorientador: João Antonio Pereira / Banca: Adriano de Almeida de Lima / Banca: Paulo Renato Junqueira Zuim / Banca: Regina Tamaki / Banca: Wilson Roberto Poi / Doutor

Page generated in 0.0922 seconds