• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 13
  • 9
  • 1
  • Tagged with
  • 63
  • 63
  • 31
  • 31
  • 29
  • 12
  • 11
  • 9
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Plaque formation and gingival inflammation as influenced by the major connector design of the mandibular removable partial denture a thesis submitted in partial fulfillment ... denture prosthodontics /

Vafa, Mehrangiz. January 1979 (has links)
Thesis (M.S.)--University of Michigan, 1979. / eContent provider-neutral record in process. Description based on print version record.
52

Avaliação clinica e radiografica de dentes retentores de protese parcial removivel em pacientes desdentados parciais Classe I de Kennedy / Clinical and radiographic evaluation of abutment tooth periodontal conditions in distal extension removable partial denture wearers

Mengatto, Cristiane Machado 09 February 2005 (has links)
Orientador: Celia Marisa Rizzati-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T08:23:17Z (GMT). No. of bitstreams: 1 Mengatto_CristianeMachado_M.pdf: 911060 bytes, checksum: 2e1e0d90cd78db26bbc3b3ab221b99f9 (MD5) Previous issue date: 2005 / Resumo: A maioria dos estudos anteriores a respeito dos efeitos do uso de próteses parciais removíveis (PPRs) sobre as condições periodontais dos dentes retentores demonstraram resultados contraditórios, e variabilidade nos métodos de padronização e avaliação. O objetivo desse estudo foi avaliar clinica e radiograficamente as condições periodontais dos dentes retentores diretos de prótese parcial removível (PPR) em pacientes edêntulas na arcada superior, e parcialmente dentadas (Classe I de Kennedy) na arcada inferior. Foram investigados: Índice Dicotômico de Placa (IPL), Índice de Sangramento à Sondagem (ISS), Mobilidade Dental (MD), Nível Clínico de Inserção Relativo (NCIR), Profundidade de Sondagem (PS), Nível da Margem Gengival (NMG), e Altura da Crista Óssea Percentual (ACOP). As avaliações foram feitas antes (t0) e após seis meses (t1) da instalação das próteses, com auxílio de sonda periodontal eletrônica de pressão controlada, guias para sondagem, registro oclusal em silicone para padronização das radiografias, e de um software (Image Tool®) para mensuração das radiografias periapicais. Para comparações que atenderam as pressuposições das análises paramétricas, utilizou-se o teste-t para amostras pareadas, para as que não atenderam, utilizou-se o teste de Wilcoxon para amostras pareadas, a 5% de significância. Entre t0 e t1, houve aumento estatisticamente significativo do IPL, ISS e MD (p<0,05); diminuição da ACOP distal (p<0,05); perda do NCIR e aumento da PS para as faces mesial, distal e lingual (p<0,05); perda do NCIR e diminuição do NMG para a face vestibular (p<0,05). Não houve diferença estatística significativa entre t0 e t1 para PS na face vestibular, ACOP mesial e NMG para a face lingual, mesial e distal (p>0,05). Considerando as condições deste estudo, concluiu-se que houve piora do acúmulo de biofilme e inflamação gengival, e das condições periodontais clínicas e radiográficas dos dentes retentores diretos após seis meses de uso da PPR de extensão distal / Abstract: Most previous studies about the influence of removable partial dentures (RPD) in periodontal conditions of abutment teeth have shown contradictory results, and variability regarding the methods of standardization and evaluation. Consequently, few comparisons can be made with the literature, as there is little systematic approach about the information reported. The aim of this study was to evaluate periodontal conditions of abutment teeth of 19 female patients (45 to 79 years old) rehabilitated with distal extension mandibular RPD and maxillary complete denture. Initially all were given oral hygiene instructions and motivation. Plaque index (PI), bleeding on probing (BOP), tooth mobility (TM), relative attachment level (RAL), probing depth (PD), gingival margin level (GML), and radiographic height of alveolar bone crest (HAC) were assessed immediately prior to (t0) and six months after (t1) prosthesis setting. Evaluations were carried with electronic periodontal probe, acrylic probing stents, and customized silicone occlusal stents to facilitate standardized periapical radiographs of abutment teeth. Radiographic measurements were taken by special software (Image Tool). Data were submitted either to paired Wilcoxon test or paired t-test, at 5% significance. There were increase in PI, BOP and TM; reduction of HAC for distal surface; attachment loss and increase in PD for mesial, distal and lingual surfaces; attachment loss and reduction in GML for buccal surface (p<0.05). There was no significant statistical difference between t0 and t1 in PD for buccal surface, HAC for mesial surface, and GML for lingual, mesial and distal surfaces (p>0.05). Within the limitations of the present study, it was concluded that biofilm accumulation, gingival inflammation, and periodontal and radiographic conditions of abutment teeth deteriorated six months after prosthesis setting / Mestrado / Protese Dental / Mestre em Clínica Odontológica
53

Fresamento corretivo de estruturas implanto-retidas : influencia na adaptação marginal e na confiabilidade do teste do parafuso unico / Multi-unit implant-supported frameworks corrective finishing : influence on the marginal misfit and reliability of single-screw test

Daroz, Luiz Gustavo Dias 24 February 2006 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T09:25:51Z (GMT). No. of bitstreams: 1 Daroz_LuizGustavoDias_M.pdf: 1050394 bytes, checksum: 25c85e7dd89cc812e9e871cdc982a3a1 (MD5) Previous issue date: 2006 / Resumo: A obtenção de uma peça perfeitamente adaptada aos componentes de retenção, mantendo a resistência estrutural a custo acessível é o principal objetivo durante a construção de uma prótese implanto-retida de múltiplos elementos. Além disto, julgar a qualidade da adaptação das peças depende da confiabilidade dos métodos existentes para determinação da passividade. O objetivo deste estudo foi determinar o desajuste marginal de infra-estruturas metálicas implanto-retidas tipo monobloco antes e após o fresamento corretivo destas peças empregando retificador manual. Avaliou-se ainda a hipótese de que os procedimentos de fresamento corretivo podem ter influência sobre a confiabilidade do teste do parafuso único utilizado para averiguação de adaptação marginal de peças múltiplas sobre implantes. Foram confeccionadas 40 infra-estruturas metálicas pela técnica do monobloco, sendo 20 fundidas em titânio comercialmente puro (Ti c.p.) e outras 20 fundidas em liga de cobalto-cromo (Cr-Cr). Para tal, utilizou-se matriz metálica simulando a disposição clínica de implantes osseointegrados na região interforames mentonianos contendo 5 análogos de pilares cônicos para peças múltiplas padrão Branemark (Micro-Unit - Conexão) e cilindros protéticos calcináveis compatíveis. As peças confeccionadas em Ti c.p. e em Co-Cr, foram subdivididas em 2 subgrupos (n=10) de acordo com a seqüência de retificação a que foram impostas: Seqüência A ¿ fresamento corretivo das bordas de adaptação dos cilindros protéticos seguido do fresamento corretivo da base de assentamento da cabeça do parafuso protético ao pilar; e, Seqüência B ¿ fresamento corretivo da base de assentamento da cabeça do parafuso protético ao pilar seguido do fresamento corretivo das bordas de adaptação dos cilindros protéticos. A conduta forneceu um total de 4 grupos experimentais (Titânio A e B; Co-Cr A e B). As leituras de desajuste marginal, realizadas sobre a matriz metálica e com auxílio de um microscópio mensurador, foram baseadas na técnica do parafuso único e realizadas em cada estrutura antes e após cada etapa de retificação corretiva. As médias de desajuste marginal de cada estrutura foram calculadas e consideradas como uma unidade para a análise estatística. O teste de Friedman foi aplicado com nível de significância de 5% para avaliar o efeito dos diferentes passos de retificação sobre o desajuste marginal. Nos Grupos Ti A e B, assim como no Grupo Co-Cr A, não foi observada diferença significativa entre as condições experimentais (Grupo Ti A, p=0,9048; Grupo Ti B, p=0,273 e Grupo Co-Cr A, p=0,4966). Porém, diferenças estatisticamente significativas foram observadas no Grupo Co-Cr B, após a retificação corretiva das bordas dos cilindros fundidos (p=0,0017). Foi concluído que os procedimentos de fresamento corretivo não mostraram efeito significativo sobre a adaptação marginal das pecas de titânio. Contudo, em um grupo de peças fundidas em Co-Cr, a retificação das bordas dos cilindros mostrou efeito adverso sobre a passividade. Os procedimentos de fresamento corretivo parecem não apresentar influência significativa sobre a confiabilidade do teste do parafuso único, porém, devem ser realizados cuidadosamente, necessitando de aperfeiçoamentos para uma utilização segura / Abstract: The fabrication of a passively fitting framework over abutments and fixtures, maintaining its structural integrity and with a low costs, is the ultimate goal of the construction process of a multi-unit implant-support prosthesis. Furthermore, the accuracy and reliability of the passive fit determination methods have a crucial hole on framework misfit analysis. The objective was to evaluate the passive fit by the single-screw test method of cast commercially pure titanium (CP Ti) implantsupported frameworks after the corrective finishing of cast cylinders fitting borders and screw seats. The hypothesis tested was that finishing procedures could affect the single screw test measurements reliability. Were fabricated 40 frameworks by onepiece casting method, being 20 CP Ti frameworks and others 20 Co-Cr frameworks. A metallic index containing 05 Branemark-type multi-unit abutment analogs and respective calcinable cylinders were used to frameworks fabrication. The CP Ti and Co-Cr frames were assembled in 2 sub-groups (n=10) accordingly with the finishing sequence proposed: Group A - corrective finishing of cast cylinder borders followed by corrective finishing of cast cylinder screw seats - and Group B - corrective finishing of cast cylinder screw seats followed by corrective finishing of cast cylinder borders-. This conduct produce 4 experimental groups (CPTi A and B; Co-Cr A and B). The marginal gaps, assessed over the metallic matrix using a traveling microscope, were carried out before and after each corrective finishing step accordingly with one screw test protocol. The marginal misfit means of each framework was considered as a unit to statistical analyses. The Friedman¿s test was used with significance level set as 5% to analyze the effect of the different corrective finishing steps over frameworks passive fit. In the CPTi A and B Groups, and in the Co-Cr A Group, there was no significant differences between experimental conditions (Group CPTi A, p=0.9048; Group CPTi B, p=0.273 and Grupo Co-Cr A, p=0.4966). However, in the CPTi B Group, a significant difference was found after cast cylinder fitting borders corrective finishing (p=0.0015). It was concluded that the finishing process does not show any effect over Ti framewoks misfit values. However, to a group of Co-Cr frames, the fitting borders corrective finishing has a deleterious effect over passivity. The corrective finishing procedures seamed do not influence the single-screw test reliability, nevertheless, it should be used carefully and requires further improvements to guarantee a sever usage / Mestrado / Protese Dental / Mestre em Clínica Odontológica
54

Avaliação qualitativa das proteses removiveis e sua relação com a qualidade de vida em idosos

Oliveira, Gesiamy Francisco de 31 July 2006 (has links)
Orientador: Eduardo Hebling / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T06:12:52Z (GMT). No. of bitstreams: 1 Oliveira_GesiamyFranciscode_M.pdf: 190517 bytes, checksum: 6ad0ddc8b300886d14c0ba4ff3b17674 (MD5) Previous issue date: 2006 / Resumo: As alterações funcionais e o estado psicológico podem influenciar a saúde bucal e o uso de próteses removíveis em pacientes idosos. A autopercepção da saúde bucal tende a influenciar a procura por atendimento e a qualidade de vida e autopercepção de saúde bucal dos idosos. O objetivo desse trabalho foi avaliar a qualidade das próteses removíveis, parciais ou totais, e sua relação com a qualidade de vida de idosos institucionalizados de Piracicaba-SP, Brasil. A amostra foi constituída de 40 pessoas, de ambos os gêneros, com média de idade de 75 anos, funcionalmente independentes ou parcialmente dependentes, sem alterações cognitivas significantes. Foi aplicado um questionário sobre as características sócio-econômicas e de saúde sistêmica da amostra. A qualidade de vida foi avaliada com uso do Geriatric Oral Health Assessment Index (GOHAI) e da Escala de Depressão Geriátrica. A qualidade das próteses removíveis foi avaliada pelo índice de Nevalainen. Os dados foram analisados por meio dos testes Qui-quadrado, Kruskal-Wallis e Mann-Whitney (a=0,05). Não houve associação estatísticamente significantes entre as variáveis sócio-econômicas, quando comparadas com a autopercepção em saúde. Quanto ao uso de próteses removíveis, 62,5% usavam em ambas arcadas; 20% somente na arcada superior e 17,5% não usavam nenhuma prótese. Do total da amostra, 62,5% apresentavam depressão. Não foram observadas diferenças estatísticas significantes entre as médias de GOHAI com relação à oclusão, articulação e dimensão vertical. Entretanto, estas médias foram influenciadas pela estabilidade e pela retenção das próteses. Pode-se concluir que as próteses removíveis podem influenciar a qualidade de vida e a autopercepção de saúde bucal em idosos / Abstract: Functional alterations and psychological status influence in the oral health and the use of removable prostheses in elderly patients. The self-perception of oral health influences in the search for oral cares and the quality of life of the aged population. The aim of this study was to assess the quality of removable prostheses, total or partial, and its relation to the quality of life in institutionalized elderly from Piracicaba-SP, Brazil. The sample was constituted for 40 subjects, both gender, mean age of 75 years old, functionally independent or partially dependent, without significant cognitive alterations. A questionnaire with questions about the sociodemographic and systemic health characteristics was applied. The quality of life was assessed using the Geriatric Oral Health Assessment Index (GOHAI) and the Geriatric Depression Scale. Removable prosthesis quality was assessed using the Nevalainen index. The data were analyzed using Chi-Square test, Mann-Whitney test and Kruskal-Wallis test (a=0.05). No significant statistics differences were found in the socioeconomic variables. In relation to the use of removable prostheses, 62.5% used prostheses in both arcades; 20% in only upper arcade, and 17.5% used no prostheses. Of total sample, 62.5% showed depression. No significant statistics differences were found between the GOHAI averages related to the occlusion, articulation, and vertical dimension of the prostheses. However, stabilization and retention of the prostheses influenced these averages. The conclusion is that the quality of life and oral health self-perception in the elderly may be influenced by the quality of removable prostheses used. / Mestrado / Mestre em Saude Coletiva
55

"Avaliação dimensional da região palatina em modelos de revestimento, após duplicação dos modelos de gesso para a confecção da estrutura metálica da prótese parcial removível, em função dos materiais duplicadores, revestimentos e da profundidade da abóbada palatina" / Dimensional evaluation of the palatal area in investment casts after the duplication of stone casts for removable partial denture framework construction in relation to the duplicating materials, investments and depth of the palatal vault.

Marcelo Alexandre Calamita 03 February 2005 (has links)
O objetivo deste estudo foi avaliar a região palatina em modelos de revestimento, após duplicação do modelo de gesso para a confecção da estrutura metálica da prótese parcial removível, em função dos materiais duplicadores, revestimentos e da profundidade da abóbada palatina. Foram utilizados 12 modelos mestres de gesso com duas diferentes profundidades da abóbada palatina, sendo seis de palato raso e seis de palato profundo. Os métodos de uplicação utilizados foram: A) Hidrocolóide reversível com revestimento aglutinado por sílica (GEL_SIL); B) Hidrocolóide reversível com revestimento aglutinado por fosfato (GEL_FOS) e C) Silicone de adição com revestimento aglutinado por fosfato (ADI_FOS). Assim, a partir de cada modelo mestre foi obtido um modelo de revestimento para cada um dos métodos descritos acima, sendo os 48 modelos resultantes aferidos com o aparelho de medição tridimensional de coordenadas e os dados analisados estatisticamente pelo método split-plot. Avaliando-se os resultados obtidos concluiu-se que: 1) Todos os métodos de duplicação produziram algum grau de imprecisão nos locais avaliados; 2) O método GEL_FOS apresentou mínimas diferenças médias em relação ao modelo mestre; 3) O método GEL_SIL apresentou diferenças médias positivas em relação ao modelo mestre, não estatisticamente significativas em relação ao método GEL_FOS; 4) O método ADI_FOS apresentou diferenças médias negativas em relação ao modelo mestre, estatisticamente significativas em relação aos métodos GEL_FOS e GEL_SIL e 5) A profundidade da abóbada palatina não influenciou significativamente os resultados obtidos. / The aim of this study was to evaluate the palatal area in investment casts after the duplication of stone casts in relation to the duplicating materials, investments and the depth of the palatal vault. Twelve master stone casts were used with two different palatal vault depths, six with a shallow palatal vault and six with a deep palatal vault. The duplicating methods used were: A) Reversible hydrocolloid with silica bonded investment (GEL_SIL); B) Reversible hydrocolloid with phosphate bonded investment (GEL_FOS), and C) Addition silicone with phosphate bonded investment (ADI_FOS). Thus, one investment cast was obtained from each master cast for each of the methods described above. The 48 resulting models were measured with a three-dimensional coordinate measurement machine, and the data were analyzed by the split-plot method. After evaluating the results we concluded that: 1) All investment casts showed some degree of distortion in the areas measured; 2) The GEL_FOS method showed the smallest average differences in relation to the master cast; 3)The GEL_SIL method showed positive, not statistically significant average differences in relation to the GEL_FOS method; 4) The ADI_FOS method showed negative, and statistically significant differences in relation to the GEL_FOS and GEL_SIL methods, and 5) The depth of the palatal vault did not influence the results significantly.
56

Fixed metal ceramic prostheses:treatment need, complications and survival of conventional fixed prosthodontics

Näpänkangas, R. (Ritva) 24 October 2001 (has links)
Abstract The aims of this study were to evaluate the treatment need of fixed bridges according to the distribution of pontics in dentition in different age groups, and to investigate the primary and late complications and survival of the conventional fixed metal ceramic prostheses, as well as patients' satisfaction with the prosthetic treatment. The whole material consisted of the patients treated with fixed metal ceramic prostheses by undergraduate students at the Institute of Dentistry during the years 1984 - 1996. There were altogether 772 patients, 460 women (60 %) and 312 men (40 %). Their mean age was 47 years (23 - 81 years). Altogether 944 single metal ceramic crowns and 543 fixed bridges (1374 abutments and 807 pontics) were prepared. It can be concluded that the fixed bridges are most often prepared to replace upper first premolars and lower first molars also in the future. The most usual primary complications related to fixed bridges occurred during preprosthetic endodontic treatment of abutment teeth and during the preparation of the root canals. Previous restoration of the prepared tooth does not have any marked effect on the prognosis of single crowns with dowels, although anatomically complicated upper lateral incisors and upper first premolars need special attention in the treatment planning. Patients were satisfied with aesthetics and function of the fixed metal ceramic prostheses. Late complications found in clinical examinations were few, and the survival rate for the fixed metal ceramic bridge prostheses was calculated to be 84 % after 10 years, long fixed bridges having a lower survival than the shorter ones. The treatment need for conventional fixed bridges seems to be highest among patients over 50 years of age in the future. Age does not influence the longevity of the fixed prostheses, but basic circumstances of the mouth, especially low secretion of saliva affected by diseases and/or medications and high scores of lactobacilli and streptococcus mutans of the saliva seem to decrease the survival.
57

Análise pelo método dos elementos finitos da distribuição de tensões em componentes protéticos posicionados em implantes com conexão cone morse na região anterior da maxila / Analysis by the finite element method of the stress distribution in prosthetic components placed in implants with morse cone connection in the anterior maxilla

López, Camilo Andrés Villabona 02 August 2012 (has links)
O objetivo desse estudo foi avaliar, por meio do método tridimensional dos elementos finitos, a distribuição de tensões na interface osso/implante e implante/pilar em implantes com conexão cone morse, posicionados na região anterior da maxila. A partir de uma reconstrução virtual óssea proveniente de uma tomografia computadorizada, foi simulada uma prótese cantilever (11-21) utilizando componente protético com pescoço de 2,5 mm de altura posicionado sobre implantes de 3,75 mm e 4,0 mm de diâmetro e 8,5 mm e 10 mm de comprimento; e prótese parcial fixa convencional (12-22) com componente protético com pescoço de 1,5 mm posicionado em implantes com 3,75 mm e 3,3 mm de diâmetro e 8,5 mm e 10 mm de comprimento. O ensaio realizado com aplicação de carga de 178 N e inclinação de 45° em relação ao longo eixo do implante na superfície palatina das próteses. A tensão de pico Equivalente Von Mises para ambos os casos clínicos foram localizados em áreas do pescoço dos componentes protéticos, plataforma e pescoço dos implantes e região óssea periimplantar. Na região dos incisivos centrais, o pico mais elevado de tensão Von mises correspondeu ao implante de 3,75 mm x 8,5 mm (370,413 MPa), e o menor ao implante de 4,0 mm x 8,5 mm valor (367, 475 MPa). No osso periimplantar a tensão de pico variou de 53,846 MPa para implante 3,75 mm x 8,5 mm à 47,284 MPa para implante 4,0 mm x 10 mm. Para implantes posicionados na região dos incisivos laterais, o valor mais elevado correspondeu ao implante de 3,3 mm x 8,5 mm (832, 911 MPa), e o menor valor ao implante de 3,75 mm x 8,5 mm (433, 666 MPa). No osso periimplantar a tensão de pico variou de 64,433 MPa, para implante 3,3 mm x 8,5 mm, à 50,277 MPa para implante 3,75 mm x 10 mm. Conclui-se que os valores e áreas de pico de tensão nos componentes protéticos posicionados em implantes com os diferentes comprimentos (8,5 mm e 10 mm) e diâmetros (3,75 mm e 4,0 mm), na região dos incisivos centrais, foram semelhantes. Implantes com mesmo diâmetro, posicionados na região dos incisivos laterais apresentaram valores e áreas de tensão semelhantes no pilar protético e osso periimplantar, independente do comprimento. Implantes com 3,3 mm de diâmetro apresentaram o dobro dos valores que implantes com 3,75 mm. / The aim of this study was to evaluate through the three-dimensional method of the finite elements the stress distribution in the bone / implant interface and implant / abutment on implants with morse cone connection, placed in the anterior maxilla. From a virtual reconstruction of bone from a CT scan, cantilever prosthesis (11-21) was simulated using prosthetic component with neck height of 2.5 mm placed in the implant with 3.75 and 4.0 mm diameter and 8.5 and 10 mm length; and conventional fixed partial denture (12-22) with prosthetic component with neck height of 1.5 mm placed in implants with 3.75 and 3.3mm of diameter and 8.5 mm and 10 mm length. The test performed with application of load of 178 N and inclination of 45 ° to the long axis of the implant in the palatal surface of the prosthesis. The peak stress concentration Equivalent Von Mises for both clinical cases were found in areas of the neck of the prosthetic components, platform and neck implants and peri-implant bone area. In the central incisors region, the highest value stressVon mises corresponded to 8.5 x 3.75 mm implant (370.413 MPa), and the lowest value to 4.0 x 8.5 mm implant (367 , 475 MPa). At the peri-implant bone the stress ranged from 53.846 MPa for 8.5 mm x 3.75 mm implant to 47,284 MPa for 4.0 mm x 10 mm implant. For implants placed in the lateral incisors region, the highest value corresponded to 3.3 x 8.5 mm implant (832 , 911 MPa ), and the lowest value to 3.75 mm x 8.5 mm implant (433, 666 MPa ). At the peri-implant bone the highest value stressVon mises ranged from 64.433 MPa for 3.3 mm x 8.5 mm implant, to 50,277 MPa for 3.75 x 10 mm implant. It follows that the values and peak areas of stress on the prosthetic components placed on implants with different lengths ( 8.5 to 10 mm) and diameter (3.75 and 4.0 mm), in the central incisors area, were similar. Implants with the same diameter, placed in the lateral incisors area showed values and areas of tension similar on the abutment and peri-implant bone area, regardless of the length. Implants with 3.3 mm diameter were twice the values that 3.75 mm implants.
58

Análise pelo método dos elementos finitos da distribuição de tensões em componentes protéticos posicionados em implantes com conexão cone morse na região anterior da maxila / Analysis by the finite element method of the stress distribution in prosthetic components placed in implants with morse cone connection in the anterior maxilla

Camilo Andrés Villabona López 02 August 2012 (has links)
O objetivo desse estudo foi avaliar, por meio do método tridimensional dos elementos finitos, a distribuição de tensões na interface osso/implante e implante/pilar em implantes com conexão cone morse, posicionados na região anterior da maxila. A partir de uma reconstrução virtual óssea proveniente de uma tomografia computadorizada, foi simulada uma prótese cantilever (11-21) utilizando componente protético com pescoço de 2,5 mm de altura posicionado sobre implantes de 3,75 mm e 4,0 mm de diâmetro e 8,5 mm e 10 mm de comprimento; e prótese parcial fixa convencional (12-22) com componente protético com pescoço de 1,5 mm posicionado em implantes com 3,75 mm e 3,3 mm de diâmetro e 8,5 mm e 10 mm de comprimento. O ensaio realizado com aplicação de carga de 178 N e inclinação de 45° em relação ao longo eixo do implante na superfície palatina das próteses. A tensão de pico Equivalente Von Mises para ambos os casos clínicos foram localizados em áreas do pescoço dos componentes protéticos, plataforma e pescoço dos implantes e região óssea periimplantar. Na região dos incisivos centrais, o pico mais elevado de tensão Von mises correspondeu ao implante de 3,75 mm x 8,5 mm (370,413 MPa), e o menor ao implante de 4,0 mm x 8,5 mm valor (367, 475 MPa). No osso periimplantar a tensão de pico variou de 53,846 MPa para implante 3,75 mm x 8,5 mm à 47,284 MPa para implante 4,0 mm x 10 mm. Para implantes posicionados na região dos incisivos laterais, o valor mais elevado correspondeu ao implante de 3,3 mm x 8,5 mm (832, 911 MPa), e o menor valor ao implante de 3,75 mm x 8,5 mm (433, 666 MPa). No osso periimplantar a tensão de pico variou de 64,433 MPa, para implante 3,3 mm x 8,5 mm, à 50,277 MPa para implante 3,75 mm x 10 mm. Conclui-se que os valores e áreas de pico de tensão nos componentes protéticos posicionados em implantes com os diferentes comprimentos (8,5 mm e 10 mm) e diâmetros (3,75 mm e 4,0 mm), na região dos incisivos centrais, foram semelhantes. Implantes com mesmo diâmetro, posicionados na região dos incisivos laterais apresentaram valores e áreas de tensão semelhantes no pilar protético e osso periimplantar, independente do comprimento. Implantes com 3,3 mm de diâmetro apresentaram o dobro dos valores que implantes com 3,75 mm. / The aim of this study was to evaluate through the three-dimensional method of the finite elements the stress distribution in the bone / implant interface and implant / abutment on implants with morse cone connection, placed in the anterior maxilla. From a virtual reconstruction of bone from a CT scan, cantilever prosthesis (11-21) was simulated using prosthetic component with neck height of 2.5 mm placed in the implant with 3.75 and 4.0 mm diameter and 8.5 and 10 mm length; and conventional fixed partial denture (12-22) with prosthetic component with neck height of 1.5 mm placed in implants with 3.75 and 3.3mm of diameter and 8.5 mm and 10 mm length. The test performed with application of load of 178 N and inclination of 45 ° to the long axis of the implant in the palatal surface of the prosthesis. The peak stress concentration Equivalent Von Mises for both clinical cases were found in areas of the neck of the prosthetic components, platform and neck implants and peri-implant bone area. In the central incisors region, the highest value stressVon mises corresponded to 8.5 x 3.75 mm implant (370.413 MPa), and the lowest value to 4.0 x 8.5 mm implant (367 , 475 MPa). At the peri-implant bone the stress ranged from 53.846 MPa for 8.5 mm x 3.75 mm implant to 47,284 MPa for 4.0 mm x 10 mm implant. For implants placed in the lateral incisors region, the highest value corresponded to 3.3 x 8.5 mm implant (832 , 911 MPa ), and the lowest value to 3.75 mm x 8.5 mm implant (433, 666 MPa ). At the peri-implant bone the highest value stressVon mises ranged from 64.433 MPa for 3.3 mm x 8.5 mm implant, to 50,277 MPa for 3.75 x 10 mm implant. It follows that the values and peak areas of stress on the prosthetic components placed on implants with different lengths ( 8.5 to 10 mm) and diameter (3.75 and 4.0 mm), in the central incisors area, were similar. Implants with the same diameter, placed in the lateral incisors area showed values and areas of tension similar on the abutment and peri-implant bone area, regardless of the length. Implants with 3.3 mm diameter were twice the values that 3.75 mm implants.
59

Polyoxymethylene as Material for Removable Partial Dentures—A Literature Review and Illustrating Case Report

Schierz, Oliver, Schmohl, Leonie, Hahnel, Sebastian, Rauch, Angelika 04 May 2023 (has links)
Compared to thermoplastic manufacturing techniques, computer-aided design (CAD) and computer-aided manufacturing (CAM) technologies make it easier to process modern restorative and prosthetic materials with improved material properties. In dentistry, tooth-colored alternatives to metal-based frameworks for application in removable dental prostheses (RDP) emerged. With regard to this aspect, the current article provides an overview of the specific material properties of polyoxymethylene (POM). Furthermore, it reviews scientific literature indexed in PubMed and Web of Science that focuses on RDPs fabricated from POM within the last 10 years. Finally, a prosthetic rehabilitation of a patient with a RDP fabricated from POM is illustrated and observations during a follow-up over 10 months are described. Scientific data and clinical observations indicate that polyoxymethylene is a promising material that bridges gaps in dental therapeutic options. While survival time may be limited due to wear, POM might be a favorable option for application in semi-permanent restorations.
60

Influência do formato do rebordo na associação de uma prótese parcial removível de extremidade livre mandibular associada ao implante com sistema de retenção ERA, pelo método dos elementos finitos

Lucas, Liliana Vicente Melo de [UNESP] 18 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-18Bitstream added on 2014-06-13T20:06:14Z : No. of bitstreams: 1 lucas_lvm_dr_araca.pdf: 2722998 bytes, checksum: 4598b84f7bad6e641b9c428ccef728d3 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Associação das próteses parciais removíveis de extremidade livre com os implantes osseointegrados é, ainda, uma opção de tratamento pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão e o deslocamento nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm com sistema ERA de retenção, em diferentes formatos de rebordo alveolar. Para tanto, foram criados oito modelos, os quais, em corte sagital, representam: Modelo A (MA) - uma hemiarcada com rebordo horizontal, sem suporte posterior, com a presença do dente 33 e de uma PPREL convencional, com apoio metálico na incisal do dente 33, em substituição aos dentes 34, 35, 36 e 37; Modelo B (MB) - semelhante ao MA, diferenciando-se deste pela presença de um implante de 3,75 x 10,00 mm com sistema ERA de retenção associado, na região posterior da base da PPREL; Modelo C (MC) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação ascendente distal; Modelo D (MD) - semelhante ao MC, diferenciando-se deste pela presença do implante com sistema de retenção associado; Modelo E (ME) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação descendente distal; Modelo F (MF) - semelhante ao ME, diferenciando-se deste pela presença do implante com sistema ERA de retenção; Modelo G (MG) - semelhante ao MA, entretanto o rebordo distal apresenta formato descendente-ascendente; Modelo H (MH) - semelhante ao MG, diferenciando-se deste pela presença do implante com sistema ERA de retenção. Com o auxílio do programa de elementos finitos ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N, em cada ponta de cúspide.... / The association of mandibular distal extension removable artial dentures with an osteointegrated implant is a treatmeat hasn't been fully explored by modern rehabilitation dentistry yet. For this reason, the objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension and the displacement on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. For that purpose, eight models were created, representing, from a sagittal perspective: Model A (MA) - a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) - similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) - similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) - similar to ME, but different in the sense that there is an implant with an associated ERA retention system; Model G (MG) - similar to MA, however with a distally descending-ascending ridge format; Model H (MH) - similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip...(Complete abstract, click electronic address below)

Page generated in 0.0855 seconds