• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 8
  • 8
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Eficiência energética em edifícios hospitalares obtida por meio de estratégias passivas: estudo da redução do consumo com climatização para arrefecimento do ar em salas de cirurgia / Energy efficiency in hospital buildings achieved through passive strategies: a study of reduced consumption with air conditioning for air-cooling in operating rooms.

Campos, Clarissa Cordeiro de 03 April 2013 (has links)
A pesquisa propõe avaliar quantitativamente a eficácia do emprego de estratégias passivas em um bloco cirúrgico hospitalar para a redução do consumo de energia elétrica com fins de arrefecimento do ar. A partir do estudo da conformação histórica do edifício hospitalar e da identificação das unidades funcionais em que é obrigatório o uso de ar condicionado; das características de geração e consumo de energia elétrica no Brasil e potenciais de economia energética em edificações, com foco em hospitais; seguidos do estabelecimento de conceitos básicos de térmica de edificações, estabeleceu-se o embasamento teórico para a realização de estudos de caso na cidade de Belo Horizonte, Minas Gerais. A análise comparativa dos dados de área física, sistemas de iluminação artificial, climatização e equipamentos coletados em seis blocos cirúrgicos possibilitou a seleção de uma unidade para construção de modelo computacional e realização de simulações em software de análise de desempenho térmico e energético de edificações. Os resultados alcançados demonstraram a importância de se considerar as condições bioclimáticas locais, em especial o controle da insolação direta, bem como reforçaram a concepção de que o projeto arquitetônico pode contribuir para a eficiência energética da edificação, mesmo quando é obrigatório o uso de ar condicionado. A realização de simulações computacionais se mostrou vantajosa, visto que possibilita a comparação de diversas opções de projeto com objetividade, antes de sua efetiva implementação. / The research quantitatively evaluate the effectiveness of the use of passive strategies in a surgical ward for reducing energy consumption for the purpose of air-cooling. The study of the historic conformation of the hospital building and the identification of the functional units in which it is mandatory the use of air conditioning; the characteristics of generation and consumption of electricity in Brazil and potential energy savings in buildings, focusing on hospitals; followed by the review of basic concepts of building heat transfer, established the theoretical basis for conducting case studies in the city of Belo Horizonte, Minas Gerais. A comparative analysis of physical area, artificial lighting, air conditioning systems and equipment data collected in six surgical wards enabled the selection of one unit to build a computational model and run simulations with the use of a software for thermal and energy performance of buildings. The results demonstrated the importance of considering local bioclimatic conditions, in particular the control of direct sunlight, as well as reinforced the concept that architectural design can contribute to the energy efficiency of the built environment, even when the use of air conditioning is mandatory. Performing computer simulations proved advantageous, since it enables objective comparison of different design options before its effective implementation.
2

Eficiência energética em edifícios hospitalares obtida por meio de estratégias passivas: estudo da redução do consumo com climatização para arrefecimento do ar em salas de cirurgia / Energy efficiency in hospital buildings achieved through passive strategies: a study of reduced consumption with air conditioning for air-cooling in operating rooms.

Clarissa Cordeiro de Campos 03 April 2013 (has links)
A pesquisa propõe avaliar quantitativamente a eficácia do emprego de estratégias passivas em um bloco cirúrgico hospitalar para a redução do consumo de energia elétrica com fins de arrefecimento do ar. A partir do estudo da conformação histórica do edifício hospitalar e da identificação das unidades funcionais em que é obrigatório o uso de ar condicionado; das características de geração e consumo de energia elétrica no Brasil e potenciais de economia energética em edificações, com foco em hospitais; seguidos do estabelecimento de conceitos básicos de térmica de edificações, estabeleceu-se o embasamento teórico para a realização de estudos de caso na cidade de Belo Horizonte, Minas Gerais. A análise comparativa dos dados de área física, sistemas de iluminação artificial, climatização e equipamentos coletados em seis blocos cirúrgicos possibilitou a seleção de uma unidade para construção de modelo computacional e realização de simulações em software de análise de desempenho térmico e energético de edificações. Os resultados alcançados demonstraram a importância de se considerar as condições bioclimáticas locais, em especial o controle da insolação direta, bem como reforçaram a concepção de que o projeto arquitetônico pode contribuir para a eficiência energética da edificação, mesmo quando é obrigatório o uso de ar condicionado. A realização de simulações computacionais se mostrou vantajosa, visto que possibilita a comparação de diversas opções de projeto com objetividade, antes de sua efetiva implementação. / The research quantitatively evaluate the effectiveness of the use of passive strategies in a surgical ward for reducing energy consumption for the purpose of air-cooling. The study of the historic conformation of the hospital building and the identification of the functional units in which it is mandatory the use of air conditioning; the characteristics of generation and consumption of electricity in Brazil and potential energy savings in buildings, focusing on hospitals; followed by the review of basic concepts of building heat transfer, established the theoretical basis for conducting case studies in the city of Belo Horizonte, Minas Gerais. A comparative analysis of physical area, artificial lighting, air conditioning systems and equipment data collected in six surgical wards enabled the selection of one unit to build a computational model and run simulations with the use of a software for thermal and energy performance of buildings. The results demonstrated the importance of considering local bioclimatic conditions, in particular the control of direct sunlight, as well as reinforced the concept that architectural design can contribute to the energy efficiency of the built environment, even when the use of air conditioning is mandatory. Performing computer simulations proved advantageous, since it enables objective comparison of different design options before its effective implementation.
3

Conforto térmico no Colégio de Aplicação Pedagógica da Universidade Estadual de Maringá: proposta para melhoria do desempenho térmico de um antigo CAIC / Thermal Comfort in the Pedagogical College of the State University of Maringá: proposal for improving the thermal performance of an old CAIC

Goulart, Mariana Fortes 07 April 2014 (has links)
O Colégio de Aplicação Pedagógica da Universidade Estadual de Maringá (CAP/UEM) fazia parte de um projeto de âmbito nacional criado na década de 1990, os Centros de Atenção Integral à Criança e ao Adolescente - CAIC´s. O projeto inicial é de autoria do arquiteto João Filgueiras Lima, Lelé, reconhecido pela preocupação com o conforto ambiental dos usuários em suas obras. Em geral, sabe-se que os alunos têm uma melhor qualidade no aprendizado quando os espaços estão bem ventilados, iluminados e silenciosos. Sendo assim, este trabalho tem como objetivo avaliar o conforto térmico no edifício do CAP/UEM verificando o desempenho das estratégias passivas para proporcionar conforto térmico, a sensação térmica dos usuários e aferindo o desempenho de uma estratégia, sugerida pelo arquiteto Lelé em entrevista a autora, para melhoria do comportamento térmico da cobertura. A metodologia proposta consiste, inicialmente, em um levantamento de dados que se destaca pela entrevista com o arquiteto. Após, foi feita uma análise projetual para a identificação e caracterização das soluções passivas de conforto e a verificação do funcionamento destas no âmbito de projeto. Para verificar a eficiência destas estratégias foi aplicado o método dos Votos Médios Preditos (PMV), que envolve medições das variáveis ambientais concomitantemente com aplicação de questionários aos alunos no período de verão. Além disso, ainda foi avaliado o desempenho térmico da cobertura, através de medições de temperaturas superficiais internas e externas comparadas entre três salas de aula: uma inalterada, outra lavada e a terceira, lavada e pintada de branco, sugestão do arquiteto Lelé para melhorar o desempenho térmico do edifício. Os resultados indicaram que a cobertura do prédio ocasiona grande ganho térmico e insatisfação dos usuários praticamente o tempo todo, prejudicando as condições de conforto no interior do edifício. Esse alto grau de desconforto pode ser explicado pela falta de manutenção e a pouca inércia térmica do sistema, principalmente da cobertura. A pintura do telhado de branco se mostrou eficiente para diminuir o calor que entra pela cobertura, ressaltando a importância da temperatura radiante para promoção das condições de conforto térmico nas salas de aula. / The Pedagogical College of the State University of Maringá (CAP/UEM) was part of a nationwide project created in the 1990s, the Centres for the Integral Care to Children and Adolescents - CAIC\'s. The initial design was concived by the architect João Filgueiras Lima (a.k.a. Lelé), acknowledged for his concern for the environmental comfort of users in his work. In general, it is known that the students have a better quality of learning when the spaces are well chilled, lighted and quiet. Therefore, this study aims to evaluate the thermal comfort in the building of the CAP/UEM checking the performance of passive strategies of thermal comfort, thermal sensation of users and verifying the performance of a strategy, suggested by the architect Lelé in an interview for the author, to improve the thermal performance of the roof. The proposed methodology consists, initially, in a collection of the datas that stands out from the interview with the architect. Afterwards, it was made an analysis projectual in order to identify passive solutions to obtain thermal comfort, at the same time, to verify the work system of this project. To check the efficiency of these strategies it was apllied the Predicted Mean Vote Method (PMV), that envolve measurements of environmental variables concurrently with questionnaires applied to students during the summer time. Futher there, it was analized the thermal performance of the roof, throught out indoor and outdoor superficial temperature measurements, compared between three classrooms: one untouchable, another washed and the third one washed and white painted, suggested by the architect Lelé to improve thermal comfort of the building. The results indicate that the roof of the building causes huge thermal gain and unsatisfaction of the users all the time, damaging the comfort conditions within the building. This high level of uncomfortable can be explained by the lack of maintenance and the low thermal inertia of the system, especially the roof. The white paint of the roof has shown efficient to reduce the heating coming throughout the roof, highlighting the importance of radiant temperature for promotion of thermal comfort conditions in classrooms.
4

Dynamic Optimization of Integrated Active - Passive Strategies for Building Enthalpy Control

Zhang, Rongpeng 01 May 2014 (has links)
The building sector has become the largest consumer of end use energy in the world, exceeding both the industry and the transportation sectors. Extensive types of energy saving techniques have been developed in the past two decades to mitigate the impact of buildings on the environment. Instead of the conventional active building environmental control approaches that solely rely on the mechanical air conditioning systems, increasing attention is given to the passive and mixed-mode approaches in buildings. This thesis aims to explore the integration of passive cooling approaches and active air conditioning approaches with different dehumidification features, by making effective use of the information on: 1) various dynamic response properties of the building system and mechanical plants, 2) diverse variations of the building boundary conditions over the whole operation process, 3) coupling effect and synergistic influence of the key operational parameters, and 4) numerous parameter conflicts in the integrated active-passive operation. These issues make the proposed integration a complex multifaceted process operation problem. In order to deal with these challenges, a systematic approach is developed by integrating a number of advanced building/system physical models and implementing well established advanced dynamic optimization algorithms. Firstly, a reduced-order model development and calibration framework is presented to generate differential-algebraic equations (DAE) based physical building models, by coupling with the high-order building energy simulations (i.e., EnergyPlus) and implementing MLE+ co-simulation programs in the Matlab platform. The reduced-order building model can describe the dynamic building thermal behaviors and address substantial time delay effects intrinsic in the building heat transfer and moisture migration. A calibration procedure is developed to balance the modelling complexity and the simulation accuracy. By making use of the advanced modeling and simulation features of EnergyPlus, the developed computational platform is able to handle real buildings with various geometric configurations, and offers the potential to cooperate with the dominant commercial building modeling software existing in the current AEC industry. Secondly, the physical model for the active air conditioning systems is developed, which is the other critical part for the dynamic optimization. By introducing and integrating a number of sub-models developed for specific building components, the model is able to specify the dynamic hygrothermal behavior and energy performance of the system under various operating conditions. Two representative air conditioning systems are investigated as the study cases: variable air volume systems (VAV) with mechanical dehumidification, and the desiccant wheel system (DW) with chemical dehumidification. The control variables and constraints representing the system operational characteristics are specified for the dynamic optimization. Thirdly, the integrated active-passive operations are formulated as dynamic optimization problems based on the above building and system physical models. The simultaneous collocation method is used in the solution algorithm to discretize the state and control variables, translating the optimization formulation into a nonlinear program (NLP). After collocation, the translated NLP problems for the daily integrated VAV/DW operation for a case zone have 1605/2181 variables, 1485/2037 equality constraints and 280/248 inequality constraints, respectively. It is found that IPOPT is able to provide the optimal solution within minutes using an 8-core 64-bit desktop, which illustrates the efficiency of the problem formulation. The case study results indicate that the approach can effectively improve the energy performance of the integrated active-passive operations, while maintaining acceptable indoor thermal comfort. Compared to the conventional local control strategies, the optimized strategies lead to remarkable energy saving percentages in different climate conditions: 29.77~48.76% for VAV and 27.85~41.33% for DW. The energy saving is contributed by the improvement of both the passive strategies (around 33%) and active strategies (around 67%). It is found that the thermal comfort constraint defined in the optimization also affects the energy saving. The total optimal energy consumption drops by around 3% if the value of the predicted percentage dissatisfied (PPD) limit is increased by one unit between 5~15%. It is also found that the fitted periodic weather data can lead to similar operation strategies in the dynamic optimization as the realistic data, and therefore can be a reasonable alternative when the more detailed realistic weather data is not available. The method described in the thesis can be generalized to supervise the operation design of building systems with different configurations.
5

Desempenho térmico de cobertura verde utilizando a grama Brachiaria humidicola na cidade de São Carlos-SP

Andrade, Nixon César de 22 August 2007 (has links)
Made available in DSpace on 2016-06-02T20:09:08Z (GMT). No. of bitstreams: 1 1676.pdf: 2206138 bytes, checksum: c83c9d5aa6bb880c23dbdaa15df8077f (MD5) Previous issue date: 2007-08-22 / This work aims to analyze the thermal behavior of a green roof with the Braquiária grass (Brachiaria humidicola), that reaches 1m height, comparing it with a traditional roof (concrete slab on show). Considering temperature and relative humidity data obtained through field measurements in different months, the thermal performance of the green and traditional roofs was analyzed. The inside and outside temperatures, and inside superficial of two test-cells were analyzed. The outside superficial temperatures were estimated through computation program and the solar radiation data and wind speed, necessaries for the use of this program, were provided by the Water Resource and Applied Ecology Center (CRHEA,) and the Engineering School of São Carlos (EESC), both from the University of São Paulo (USP). The results indicate that, submitted to the local climate, the green roof presents optimum performance, particularly for decreasing the temperatures of external and internal roof surfaces. In the same test-cell it was recently realized a similar research, which used the Esmeralda grass (Zoysia japonica), a short vegetation. Comparing the measurement results for cold and hot periods, it was noticed differences between the thermal performance of the two grasses. / O objetivo deste trabalho é analisar o comportamento térmico de uma cobertura ajardinada com a grama Braquiária (Brachiaria humidicola), que atinge 1m de altura, comparando-a com a de uma cobertura tradicional (laje exposta). Considerando-se os dados obtidos por meio de monitoramentos com aparelhos registradores de temperaturas e umidades relativas, em diferentes épocas do ano, analisou-se o comportamento térmico das coberturas tradicional e verde. Foram medidas as temperaturas do ar no interior e no exterior das células-teste e as superficiais internas de ambas as células. As temperaturas superficiais externas foram estimadas por programa computacional e os dados de radiação solar e velocidade do vento, necessários para a utilização desse programa, foram fornecidos pelo Centro de Recursos Hídricos e Ecologia Aplicada (CRHEA) e pela Escola de Engenharia de São Carlos (EESC), ambos da Universidade de São Paulo (USP). Os resultados indicam que, submetida ao clima local, a cobertura ajardinada apresenta ótimo desempenho, particularmente por amortecer as temperaturas das superfícies externas e internas da cobertura. Nessa mesma célula-teste realizou-se recentemente uma pesquisa similar, mas que utilizou a grama Esmeralda (Zoysia japonica), uma vegetação rasteira. Comparando-se os resultados dos monitoramentos realizados, nos períodos de frio e calor, foram detectadas diferenças entre os comportamentos térmicos das duas gramas.
6

Conforto térmico no Colégio de Aplicação Pedagógica da Universidade Estadual de Maringá: proposta para melhoria do desempenho térmico de um antigo CAIC / Thermal Comfort in the Pedagogical College of the State University of Maringá: proposal for improving the thermal performance of an old CAIC

Mariana Fortes Goulart 07 April 2014 (has links)
O Colégio de Aplicação Pedagógica da Universidade Estadual de Maringá (CAP/UEM) fazia parte de um projeto de âmbito nacional criado na década de 1990, os Centros de Atenção Integral à Criança e ao Adolescente - CAIC´s. O projeto inicial é de autoria do arquiteto João Filgueiras Lima, Lelé, reconhecido pela preocupação com o conforto ambiental dos usuários em suas obras. Em geral, sabe-se que os alunos têm uma melhor qualidade no aprendizado quando os espaços estão bem ventilados, iluminados e silenciosos. Sendo assim, este trabalho tem como objetivo avaliar o conforto térmico no edifício do CAP/UEM verificando o desempenho das estratégias passivas para proporcionar conforto térmico, a sensação térmica dos usuários e aferindo o desempenho de uma estratégia, sugerida pelo arquiteto Lelé em entrevista a autora, para melhoria do comportamento térmico da cobertura. A metodologia proposta consiste, inicialmente, em um levantamento de dados que se destaca pela entrevista com o arquiteto. Após, foi feita uma análise projetual para a identificação e caracterização das soluções passivas de conforto e a verificação do funcionamento destas no âmbito de projeto. Para verificar a eficiência destas estratégias foi aplicado o método dos Votos Médios Preditos (PMV), que envolve medições das variáveis ambientais concomitantemente com aplicação de questionários aos alunos no período de verão. Além disso, ainda foi avaliado o desempenho térmico da cobertura, através de medições de temperaturas superficiais internas e externas comparadas entre três salas de aula: uma inalterada, outra lavada e a terceira, lavada e pintada de branco, sugestão do arquiteto Lelé para melhorar o desempenho térmico do edifício. Os resultados indicaram que a cobertura do prédio ocasiona grande ganho térmico e insatisfação dos usuários praticamente o tempo todo, prejudicando as condições de conforto no interior do edifício. Esse alto grau de desconforto pode ser explicado pela falta de manutenção e a pouca inércia térmica do sistema, principalmente da cobertura. A pintura do telhado de branco se mostrou eficiente para diminuir o calor que entra pela cobertura, ressaltando a importância da temperatura radiante para promoção das condições de conforto térmico nas salas de aula. / The Pedagogical College of the State University of Maringá (CAP/UEM) was part of a nationwide project created in the 1990s, the Centres for the Integral Care to Children and Adolescents - CAIC\'s. The initial design was concived by the architect João Filgueiras Lima (a.k.a. Lelé), acknowledged for his concern for the environmental comfort of users in his work. In general, it is known that the students have a better quality of learning when the spaces are well chilled, lighted and quiet. Therefore, this study aims to evaluate the thermal comfort in the building of the CAP/UEM checking the performance of passive strategies of thermal comfort, thermal sensation of users and verifying the performance of a strategy, suggested by the architect Lelé in an interview for the author, to improve the thermal performance of the roof. The proposed methodology consists, initially, in a collection of the datas that stands out from the interview with the architect. Afterwards, it was made an analysis projectual in order to identify passive solutions to obtain thermal comfort, at the same time, to verify the work system of this project. To check the efficiency of these strategies it was apllied the Predicted Mean Vote Method (PMV), that envolve measurements of environmental variables concurrently with questionnaires applied to students during the summer time. Futher there, it was analized the thermal performance of the roof, throught out indoor and outdoor superficial temperature measurements, compared between three classrooms: one untouchable, another washed and the third one washed and white painted, suggested by the architect Lelé to improve thermal comfort of the building. The results indicate that the roof of the building causes huge thermal gain and unsatisfaction of the users all the time, damaging the comfort conditions within the building. This high level of uncomfortable can be explained by the lack of maintenance and the low thermal inertia of the system, especially the roof. The white paint of the roof has shown efficient to reduce the heating coming throughout the roof, highlighting the importance of radiant temperature for promotion of thermal comfort conditions in classrooms.
7

Conforto térmico nos edifícios das indústrias de calçados de Jaú / Thermal comfort in footwear industry from Jaú

Prado, Monica Faria de Almeida 25 April 2012 (has links)
Este trabalho aborda o desempenho térmico obtido em edifícios industriais do setor calçadista, perante a importância em obter condições ambientais favoráveis à execução das atividades através de uma arquitetura adequada ao contexto climático. Assim, o objetivo nesta pesquisa é avaliar as condições de conforto térmico oferecidas pelos edifícios das indústrias calçadistas do município de Jaú, um importante pólo industrial do setor no interior de São Paulo. Caracterizam-se as tipologias construtivas dos edifícios quanto à geometria, materiais e sistema de ventilação. As estratégias passivas para obtenção de conforto térmico nos galpões fabris são identificadas e avaliadas utilizando as recomendações presentes na NBR 15220. Para avaliar as condições de conforto térmico, foram medidas as variáveis ambientais, sendo que a temperatura foi analisada sob condições de aceitabilidade térmica, conforme estabelecido pela ASHRAE 55-2010. Para estimar a sensação térmica dos usuários, são utilizados os índices PMV e PPD. Também foi aplicado um questionário para verificar o nível de satisfação dos funcionários com o ambiente de trabalho. Os resultados apontam que a maioria dos edifícios apresenta uma tipologia semelhante, com geometria retangular e ventilação realizada através de esquadrias nas fachadas. A ausência de diversas estratégias passivas resulta em um edifício com baixa inércia térmica e vulnerável às condições climáticas externas, sendo que em períodos quentes a temperatura interna foi superior a 30ºC, e em períodos frios inferior a 15ºC. A sensação térmica dos usuários na maior parte do período do expediente corresponde ao desconforto térmico para o calor, principalmente no período vespertino, sendo que a porcentagem de insatisfeitos ultrapassa 80%. Deste modo, há necessidade de otimizar a adoção de estratégias passivas, para proporcionar melhores condições térmicas de trabalho. Para isto, são indicadas soluções simples, que propiciam melhorias ao desempenho térmico dos edifícios, exemplificando: o uso de sistemas que possibilitem o resfriamento evaporativo e ampliação das áreas de aberturas destinadas à ventilação do edifício. / This paper discusses the thermal performance obtained in industrial buildings in the footwear sector, given the importance of obtaining favorable environmental conditions for the execution of activities through an architecture suited to the climate context. Thus, the objective of this research is to evaluate the thermal comfort conditions provided by the buildings of the footwear industries of Jaú city, an important industrial pole. It is characterized the typologies of building\'s construction regarding its geometry, materials and ventilation system. The passive strategies for achieving thermal comfort in the factory sheds are identified and evaluated using the recommendations present in the NBR 15220. To evaluate the thermal comfort conditions it was measured the environmental variables, and the temperature was examined under conditions of thermal acceptability, as established by ASHRAE 55-2010. In order to estimate the thermal sensation of the users, the PMV and PPD indices were used. Also, a questionnaire was applied in order to check the level of employee satisfaction with the working environment. The results show that most of the buildings presents a typology similar with a rectangular geometry and ventilation obtained through frames at the facades. The absence of different passive strategies results in a building with a low thermal inertia and vulnerable to the external weather conditions, and in hot periods, the internal temperature was above 30°C, and during colder periods it was lower than 15°C. The thermal sensation of users in most of the period of the working shift matches the thermal discomfort to the heat, especially in the afternoon, and the percentage of discontentment exceeds 80%. This way, there is a need to optimize the adoption of passive strategies, to provide better thermal conditions of work. For this purpose, simple solutions that provide improvements to the thermal performance of buildings are given, examples: the use of systems which allows evaporative cooling and expansion of openings areas for the ventilation of the building.
8

Conforto térmico nos edifícios das indústrias de calçados de Jaú / Thermal comfort in footwear industry from Jaú

Monica Faria de Almeida Prado 25 April 2012 (has links)
Este trabalho aborda o desempenho térmico obtido em edifícios industriais do setor calçadista, perante a importância em obter condições ambientais favoráveis à execução das atividades através de uma arquitetura adequada ao contexto climático. Assim, o objetivo nesta pesquisa é avaliar as condições de conforto térmico oferecidas pelos edifícios das indústrias calçadistas do município de Jaú, um importante pólo industrial do setor no interior de São Paulo. Caracterizam-se as tipologias construtivas dos edifícios quanto à geometria, materiais e sistema de ventilação. As estratégias passivas para obtenção de conforto térmico nos galpões fabris são identificadas e avaliadas utilizando as recomendações presentes na NBR 15220. Para avaliar as condições de conforto térmico, foram medidas as variáveis ambientais, sendo que a temperatura foi analisada sob condições de aceitabilidade térmica, conforme estabelecido pela ASHRAE 55-2010. Para estimar a sensação térmica dos usuários, são utilizados os índices PMV e PPD. Também foi aplicado um questionário para verificar o nível de satisfação dos funcionários com o ambiente de trabalho. Os resultados apontam que a maioria dos edifícios apresenta uma tipologia semelhante, com geometria retangular e ventilação realizada através de esquadrias nas fachadas. A ausência de diversas estratégias passivas resulta em um edifício com baixa inércia térmica e vulnerável às condições climáticas externas, sendo que em períodos quentes a temperatura interna foi superior a 30ºC, e em períodos frios inferior a 15ºC. A sensação térmica dos usuários na maior parte do período do expediente corresponde ao desconforto térmico para o calor, principalmente no período vespertino, sendo que a porcentagem de insatisfeitos ultrapassa 80%. Deste modo, há necessidade de otimizar a adoção de estratégias passivas, para proporcionar melhores condições térmicas de trabalho. Para isto, são indicadas soluções simples, que propiciam melhorias ao desempenho térmico dos edifícios, exemplificando: o uso de sistemas que possibilitem o resfriamento evaporativo e ampliação das áreas de aberturas destinadas à ventilação do edifício. / This paper discusses the thermal performance obtained in industrial buildings in the footwear sector, given the importance of obtaining favorable environmental conditions for the execution of activities through an architecture suited to the climate context. Thus, the objective of this research is to evaluate the thermal comfort conditions provided by the buildings of the footwear industries of Jaú city, an important industrial pole. It is characterized the typologies of building\'s construction regarding its geometry, materials and ventilation system. The passive strategies for achieving thermal comfort in the factory sheds are identified and evaluated using the recommendations present in the NBR 15220. To evaluate the thermal comfort conditions it was measured the environmental variables, and the temperature was examined under conditions of thermal acceptability, as established by ASHRAE 55-2010. In order to estimate the thermal sensation of the users, the PMV and PPD indices were used. Also, a questionnaire was applied in order to check the level of employee satisfaction with the working environment. The results show that most of the buildings presents a typology similar with a rectangular geometry and ventilation obtained through frames at the facades. The absence of different passive strategies results in a building with a low thermal inertia and vulnerable to the external weather conditions, and in hot periods, the internal temperature was above 30°C, and during colder periods it was lower than 15°C. The thermal sensation of users in most of the period of the working shift matches the thermal discomfort to the heat, especially in the afternoon, and the percentage of discontentment exceeds 80%. This way, there is a need to optimize the adoption of passive strategies, to provide better thermal conditions of work. For this purpose, simple solutions that provide improvements to the thermal performance of buildings are given, examples: the use of systems which allows evaporative cooling and expansion of openings areas for the ventilation of the building.

Page generated in 0.1073 seconds