• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • Tagged with
  • 27
  • 27
  • 27
  • 25
  • 25
  • 21
  • 18
  • 18
  • 16
  • 11
  • 9
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise teórico-experimental de ligações parafusadas viga-pilar em perfis formados a frio.

Morais, Cassius Soares January 2003 (has links)
Programa de Pós Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. / Submitted by giuliana silveira (giulianagphoto@gmail.com) on 2016-01-21T17:38:43Z No. of bitstreams: 1 DISSERTAÇÃO_AnáliseTeóricoExperimentalLigações.pdf: 3427759 bytes, checksum: a4fd1be81ffd744d9fb55765cd29c5ab (MD5) / Approved for entry into archive by Oliveira Flávia (flavia@sisbin.ufop.br) on 2016-01-21T17:59:51Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO_AnáliseTeóricoExperimentalLigações.pdf: 3427759 bytes, checksum: a4fd1be81ffd744d9fb55765cd29c5ab (MD5) / Made available in DSpace on 2016-01-25T12:28:13Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO_AnáliseTeóricoExperimentalLigações.pdf: 3427759 bytes, checksum: a4fd1be81ffd744d9fb55765cd29c5ab (MD5) Previous issue date: 2003 / Neste presente trabalho são apresentados estudos teórico-experimentais para avaliar o comportamento de ligações viga-coluna parafusadas utilizando seções transversais em perfis formados a frio de duas edificações pertencentes ao projeto vencedor do 2o Prêmio Arquitetura em Aço, patrocinado pela USIMINAS, Projeto USIHAB. Este contém um projeto de dois pavimentos (Projeto 01) e um de quatro pavimentos (Projeto 02). Foram realizadas análises estruturais e dimensionamentos de ambos os projetos. Em seguida, determinou-se um protótipo de ensaio (P01) formado por um conjunto viga-coluna de seção transversal tipo caixa mais representativo do Projeto 02 para o qual foi projetada uma ligação parafusada. Para esta ligação realizou-se o teste experimental e verificou-se que esse protótipo apresentava um modo de colapso bastante frágil, então fez-se novas análises que originou uma nova configuração para a ligação, Protótipo P01B. Os resultados desse teste não se apresentaram satisfatórios, pois para tal solução a ligação teria um peso em aço representativo do peso total da estrutura inviabilizando a sua execução. Como para os protótipos referentes ao Projeto 02 não se obteve resultados satisfatórios, foi permitida uma flexibilização no Projeto 01 que passou pela mudança na arquitetura e alterações da seção transversal dos pilares para perfis de seção transversal tipo “I enrijecido” formado por dois perfis cartola. Para as análises de ligações do Projeto 01, onde em sua concepção são utilizados pilares “I enrijecidos” e vigas tipo caixa, obteve-se melhores resultados. Foram realizados oito testes experimentais com três tipos de protótipos e, assim, obteve-se a curva momento-rotação e a rigidez da ligação, os momentos últimos, os modos de colapso, os campos de deslocamento e de deformação de cada ligação. Em seguida fez-se uma segunda análise para o Projeto 01 utilizando as rigidezes das ligações obtidas nos testes experimentais e observou-se um aumento de 6,0 % na taxa (kg/m2) da estrutura nessa segunda análise em relação à primeira que não implicará necessariamente em gastos maiores para a edificação em função da utilização das ligações parafusadas. ______________________________________________________________ / ABSTRACT : In this present work are introduced theoretician-experimental studies to evaluate the behavior of bolt beam-column connections using transversal sections in cold formed steel members of two buildings to the winner project of the 2th Prize Architecture in Steel, sponsored by USIMINAS, USIHAB Project. This contains a project of two floors (Project 01) and one of four floors (Project 02). It accomplished structural analyses and designs from both projects. It determined a test prototype (P01) formed by a connection beam-column of transversal section more representative kind box of the Project 02 to which was projected a bolted connection. For this connection it accomplished the experimental test and verified itself that prototype introduced a way of very fragile collapse, then new analyses were done originated a new configuration for the connection, Prototype P01B. The results of this test did not introduce satisfactory, because for such solution the connection would have a weight in representative steel of the total weight of the structure making unfeasible your execution. As for the referring prototypes to the Project 02 did not obtain satisfactory results, it was allowed a flexibility in the Project 01 that passed by the change in the architecture and alterations of the transversal section of the pillars for members of transversal section kind “I” formed for double top hat back-to-back. For the connections analyses of the Project 01, where in your conception are used pillars “I” and kind box beams, it obtained best results. They were done eight experimental tests with three kinds of prototypes and, therefore, it obtained the momentrotation curve and the stiffness of the connection, the last moments, the collapse manners, the displacement field and of deformation of each connection. A second analysis was done for the Project 01 using the stiffness of the connections obtained in the experimental tests and an increase of 6,0 % was observed in the rate (kg/m2) of the structure on second analysis regarding the first that necessarily will not imply in larger expenses for the construction in function of the utilization of the bolted connections.
2

Estudo teórico-experimental de sistemas de armazenagem industrial tipo Drive-in.

Campos, Simone Rodrigues January 2003 (has links)
Programa de Pós Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. / Submitted by giuliana silveira (giulianagphoto@gmail.com) on 2016-02-15T16:41:05Z No. of bitstreams: 1 DISSERTAÇÃO_EstudoTeóricoExperimentalSistemas.pdf: 2483971 bytes, checksum: f88c97824d253148d1fe18d72ddd039b (MD5) / Approved for entry into archive by Oliveira Flávia (flavia@sisbin.ufop.br) on 2016-02-15T18:47:44Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO_EstudoTeóricoExperimentalSistemas.pdf: 2483971 bytes, checksum: f88c97824d253148d1fe18d72ddd039b (MD5) / Made available in DSpace on 2016-04-12T17:53:06Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO_EstudoTeóricoExperimentalSistemas.pdf: 2483971 bytes, checksum: f88c97824d253148d1fe18d72ddd039b (MD5) Previous issue date: 2003 / Neste trabalho apresenta-se um estudo do comportamento de sistemas de armazenagem industrial do tipo Drive-in. Apesar de ser uma estrutura composta de perfis formados a frio, o seu projeto não pode ser baseado nas normas tradicionais de dimensionamento. Isto porque os sistemas de armazenagem industrial possuem como característica própria perfurações ao longo dos perfis que compõem as colunas e que são utilizados para facilitar o encaixe das vigas. Para o presente estudo foram utilizadas as prescrições de norma do RMI - Rack Manufacturers Institute com algumas modificações para abranger o sistema Drive-in Por ser uma estrutura esbelta e composta por perfis formados a frio, a estabilidade do sistema Drive-in é importante, sendo interessante conhecer a rigidez real das ligações. Neste trabalho foi avaliada experimentalmente a rigidez da ligação colunaplaca de base, enquanto os valores de rigidez das demais ligações foram obtidos em estudos anteriores. As análises foram feitas através de um software em elementos finitos, em que a estrutura foi modelada com elementos de viga e elementos de mola. Estudou-se o tipo de análise que melhor representa o comportamento da estrutura: linear ou não linear, bidimensional ou tridimensional; avaliou-se a perda de influência do plano de contraventamento dos fundos nas colunas frontais; validou-se a obtenção da área efetiva da coluna através da tensão nominal segundo a NBR-14672; estudou-se a importância da consideração dos dados experimentais no comportamento global da estrutura, aplicaram-se forças horizontais como forma de representar a estrutura fora do prumo e foram feitas algumas considerações sobre a determinação da carga crítica da coluna. Essas análises têm como objetivo conhecer o comportamento e propor recomendações para projeto de sistemas do tipo Drive-in. ___________________________________________________________________________________ / ABSTRACT: This work studies the behavior of the Drive-in, which is a steel storage rack system. Although these systems consist of thin cold-formed steel sections, their projects cannot be based on the traditional codes. It happens because there are holes en the columns of the racks. These holes are used to make the rabbet of the beams easier. In this study was used a specific code to steel storage racks systems of the RMI - Rack Manufacturers Institute with some modifications because this code doesn’t enclose the Drive-in system. Being a slender structure, the stability of the Drive-in system is important, and then in this case the knowledge of the true stiffness of the joining is important. At the present work the stiffness of de base plates was determined by test. The values of the others stiffness used in this study are the previous studies. A study about a better analysis – linear or non-linear and 2D or 3D – to represent the structure behavior was made by software in finite elements, where the structure was shaped with beam and spring elements. The influence of the bracing was evaluated in the front columns. The calculation of the column’s area through the NBR-14672’s stress was validated. The experimental data in the global behavior of the structure was considered important. Horizontal forces were applied as form to the effect of the out-ofplumbness in the structure and some considerations were made about the critical load of the column. These analyses have as objective to know the behavior and to consider recommendations for project of Drive-in system.
3

Comportamento estrutural e dimensionamento de cantoneiras de aço formadas a frio submetidas à compressão / Structural behavior and design of cold-formed steel angle columns

Mesacasa Júnior, Enio Carlos 27 April 2012 (has links)
Envolto ao já conhecido comportamento de cantoneiras esbeltas de abas iguais, questões aparentemente contraditórias tem sido reportadas em estudos experimentais de diversos autores, entre elas a ocorrência de modos de instabilidade em desacordo com aqueles obtidos via análise de estabilidade elástica, e forças axiais resistentes muito diferentes dos resultados teóricos (em geral, conservadoramente). Nestas condições, este trabalho procura analisar a fundo o comportamento das cantoneiras esbeltas de abas iguais, de modo a contribuir com o entendimento dos fenômenos que dificultam a interpretação dos resultados experimentais, dentre os quais, o afastamento longitudinal entre a rótula e a extremidade das barras (no caso de barras com extremidades rotuladas), e o sentido da imperfeição global de flexão em torno do eixo de menor inércia, o qual mostrou-se um fator chave na determinação do comportamento das cantoneiras, especialmente para comprimentos próximos da transição entre os dois modos globais de instabilidade elástica. Para esta faixa de comprimentos, diferentes níveis de interação entre os dois modos globais podem ser obtidos. Ademais, estudos experimentais realizados por diversos autores, aqui complementados por uma série de ensaios realizados em cantoneiras com extremidades engastadas, formam um vasto banco de resultados, que é utilizado para (além de comparações nos estudos teóricos) avaliar diversos procedimentos de previsão teórica sugeridos por diferentes autores, ou advindos de interpretações a partir do procedimento normativo, à luz do comportamento teórico estudado na primeira etapa do trabalho. Assim, destes procedimentos, apenas um baseado no Método da Resistência Direta, e dois baseados no Método das Larguras Efetivas demonstraram bons resultados, sendo que todos eles, desconsiderando o modo de flexo-torção como um modo global de instabilidade. Ao fim, comenta-se da necessidade de se expandir alguns estudos específicos, pois ao adotar-se um procedimento baseado somente no modo global de flexão, apesar de se mostrar estatisticamente mais eficiente, verifica-se a possível ocorrência de resultados demasiadamente contra a segurança. / On the well known behavior of equal-leg angle columns, some questions apparently paradoxical have been reported in experimental results from several authors, including the occurrence of different instability modes from the expected by the elastic stability analysis, and maximum axial compressive load expressly different (generally conservative) from theoretical previsions. Therefore, the aim of this work is to improve the knowledge about the equal-leg angle columns behavior, contributing to the understanding of the features that complicate the interpretation of experimental results, among which, the longitudinal distance between the end sections and the center of hinges (pin-ended columns), and also the direction of the minor-axis flexural initial imperfection, which proved to play a key role in the post-critical column behavior, specially for column lengths near of the transition between global buckling modes (major-axis flexural-torsional and minor-axis flexural modes). On this range of lengths, different modal interaction amplitudes can be obtained, only with the direction of the minor-axis flexural initial imperfection (i.e., the amplitude of this imperfection plays a negligible influence on the column behavior). Furthermore, putting together a fairly large column ultimate strength data bank comprising experimental test results performed by several authors, collected from the available literature, and new experimental results on fixed-ended angle columns performed in this work, important comparisons with theoretical studies can be showed as well as evaluation of several ultimate strength theoretical prevision procedures, either those suggested by another authors as those arising from interpretations of normative procedures in the light of theoretical behavior verified in the first stage of labor. In conclusion, only one procedure based on Direct Strength Method and two procedures based on Effective Width Method exhibited accurate results, all of which neglecting the flexural-torsional mode as a global mode. Thus, it is important to mention that some additional studies are needed, because if adopted a procedure based only in the minor-axis flexural mode, despite being statistically advantageous, it is verified the possibility to occurs quite unconservative results.
4

Ligações metálicas constituídas por parafusos auto-atarraxantes / Steel connections constituted of screws

Freitas, Márcio Felix de 01 September 2004 (has links)
O emprego de parafusos auto-atarraxantes em ligações metálicas, nos últimos anos, têm aumentado de forma significativa, principalmente como dispositivo de ligação entre componentes leves da construção metálica, como por exemplo, nas ligações entre telhas metálicas e terças. Tais ligações apresentam modos de falha diferentes dos observados para as ligações parafusadas convencionais, em função do tipo de parafuso e das reduzidas espessuras dos elementos conectados, definidos como \"pull-out\" e \"pull-over\". No Brasil, a carência de estudos específicos nesse tema foi uma das razões da omissão da recente norma brasileira de dimensionamento de estruturas de aço constituídas por perfis formados a frio - NBR 14762:2001, quanto a procedimentos específicos para o projeto de ligações com parafusos auto-atarraxantes. Nesse trabalho foi desenvolvido um estudo abrangente sobre as ligações metálicas com parafusos auto-atarraxantes, com ênfase na ligação telha-terça, onde são apresentados os procedimentos e as recomendações das principais normas estrangeiras, bem como os ensaios padronizados para caracterização dos parafusos e avaliação do comportamento estrutural e resistência de ligações. São apresentados também os resultados de uma investigação experimental, com base no ensaio padrão do AISI (1996) (American Iron and Steel Institute), em 27 corpos-de-prova com variação no diâmetro do parafuso e espessura dos componentes da ligação (terça e telha), com o objetivo principal de avaliar as expressões das AISI (2001b e 1996) para dimensionamento. Como conclusão, são relatadas as dificuldades associadas ao ensaio padrão, que apesar de sua concepção simples, conduz à elevada variabilidade nos resultados, indicando a necessidade da adoção de ensaios mais representativos e confiáveis. / The use of screws in steel connections has increased significantly in recent years, mainly as connecting devices between light-gage components in steel construction, as, for example, in joints between metal roofing and purlins. These connections exhibit different failure modes from those displayed by conventional bolted connections, due to the type of fastener and the reduced thicknesses of the connected elements, defined as pull-out and pull-over. In Brazil, the lack of specific studies of this theme was one of the reasons for the omission of specific procedures for the design of screw connections from the new edition of the brazilian code for cold-formed steel members - NBR 14762:2001. The work reported here involved a comprehensive study of steel connections using screws, with emphasis on the sheating-purlin connection. A presentation is made of the procedures and recommendations of the main foreign codes, as well as of standardized tests for characterizing screws and evaluating the structural behavior and strength of connections. Also presented are the results of an experimental investigation based on the standard test of the AISI (1996) (American Iron and Steel Institute) applied to 27 test specimens with varying screw diameters and connector component thicknesses (purlin and sheeting), whose main purpose was to evaluate the AISI\'s design equations (2001b e 1996). To conclude, a report is made of the difficulties associated with the standard test, which, despite its simple conception, leads to considerably variable results, indicating the need for the adoption of more representative and reliable tests.
5

Estudo teórico de perfis formados a frio em situação de incêndio / Theoretical study of cold-formed steel members in fire situation

Mendes, Cristiane Lopes 15 September 2004 (has links)
Com a publicação das normas NBR 14323:1999 Dimensionamento de estruturas de aço de edifícios em situação de incêndio e NBR 14432:2000 Exigências de resistência ao fogo de elementos construtivos de edificações, despertou-se, ainda mais, a preocupação com o dimensionamento das estruturas em caso de incêndio. Quando o aço é exposto a altas temperaturas apresenta reduções na resistência ao escoamento e no módulo de elasticidade. Em função dessas reduções, a NBR 14432:2000 apresenta tempos requeridos de resistência ao fogo, com os quais, pode-se optar pelo dimensionamento da estrutura, apresentado na NBR 14323:1999, ou pelo revestimento térmico. No entanto, essa última norma não permite a utilização do método simplificado de dimensionamento para perfis formados a frio. Quanto aos revestimentos térmicos, o mais utilizado no Brasil é a argamassa projetada, não adequada aos perfis formados a frio. O presente trabalho faz um breve histórico sobre estruturas de aço em situação de incêndio, sobre perfis formados a frio em temperatura ambiente e em situação de incêndio, além de apresentar tipos de revestimentos térmicos e suas aplicações. Finalmente sugere uma possível maneira de dimensionamento por meio da NBR 14762:2001 Dimensionamento de estruturas de aço constituídas por perfis formados a frio com adaptações para situação de incêndio e de proteção desses perfis em situação de incêndio. / The interest in design of steel structures in fire situation carried out in consequence of publication of Brazilians codes ABNT/NBR 14323:1999 named \"Steel structures fire design - Procedure\" and ABNT/NBR 14432:2000 \"Fire-resistance requirements for building construction elements - Procedure\". When the steel is exposed to elevated temperatures (for example, fire situation) reductions in the strength and deformation properties must be considered. In this sense, the code ABNT/NBR 14432:2000 prescribes values of parameter TRRF (Fire strength required time), with are used for design of steel structures using a simplified method prescribed in ABNT/NBR 14323:1999, or specifying fireproofing. However, this last code doesn\'t prescribe a simplified method for cold-formed steel in fire condition, and the fireproofing materials largely used in Brazil are the sprays, which are not appropriate to cold-formed profiles. In this sense, the main goal of the present work is show a brief context about steel structures in fire conditions, in special cold-formed profiles in room temperature and fire situation, and many types of fire protection materials used in steel structures and its applications. Finally, is suggested a design method to cold-formed profiles in fire, adopting the code ABNT/NBR 14762:2001 \"Design of cold-formed steel structures\", in which appropriate adaptations are considered, as well as a protection procedure to this profiles in fire conditions.
6

Recuperação estrutural de edificações históricas utilizando perfis formados a frio / Structural recovery of a historical construction by means of cold-formed sections

Borges, Marcos Leopoldo 28 September 2001 (has links)
Este trabalho apresenta a proposta de recuperação estrutural de uma edificação histórica no município de Uberaba por meio de perfis formados a frio. Para o dimensionamento e cálculo dos elementos estruturais foi utilizado o projeto de norma brasileira de dimensionamento de estruturas de aço constituídas por perfis formados a frio. São apresentados os critérios e procedimentos para a recuperação de estruturas em geral e especificamente para as edificações antigas ou históricas. É feita uma análise da viabilidade técnica, da utilização de perfis formados a frio na recuperação estrutural de obras históricas. / This work presents the proposal of structural recovery of a historical construction in Uberaba city, by means of cold-formed sections. It was used the steel structures increasing brazilian norm project, composed of cold-formed sections. It is presented the criteria and procedures for the general structural recovery to the old or historical constructions. It is also made an analysis of technical viability of cold-formed sections utilization in structural recovery of historical works.
7

Estudo teórico de perfis formados a frio em situação de incêndio / Theoretical study of cold-formed steel members in fire situation

Cristiane Lopes Mendes 15 September 2004 (has links)
Com a publicação das normas NBR 14323:1999 Dimensionamento de estruturas de aço de edifícios em situação de incêndio e NBR 14432:2000 Exigências de resistência ao fogo de elementos construtivos de edificações, despertou-se, ainda mais, a preocupação com o dimensionamento das estruturas em caso de incêndio. Quando o aço é exposto a altas temperaturas apresenta reduções na resistência ao escoamento e no módulo de elasticidade. Em função dessas reduções, a NBR 14432:2000 apresenta tempos requeridos de resistência ao fogo, com os quais, pode-se optar pelo dimensionamento da estrutura, apresentado na NBR 14323:1999, ou pelo revestimento térmico. No entanto, essa última norma não permite a utilização do método simplificado de dimensionamento para perfis formados a frio. Quanto aos revestimentos térmicos, o mais utilizado no Brasil é a argamassa projetada, não adequada aos perfis formados a frio. O presente trabalho faz um breve histórico sobre estruturas de aço em situação de incêndio, sobre perfis formados a frio em temperatura ambiente e em situação de incêndio, além de apresentar tipos de revestimentos térmicos e suas aplicações. Finalmente sugere uma possível maneira de dimensionamento por meio da NBR 14762:2001 Dimensionamento de estruturas de aço constituídas por perfis formados a frio com adaptações para situação de incêndio e de proteção desses perfis em situação de incêndio. / The interest in design of steel structures in fire situation carried out in consequence of publication of Brazilians codes ABNT/NBR 14323:1999 named \"Steel structures fire design - Procedure\" and ABNT/NBR 14432:2000 \"Fire-resistance requirements for building construction elements - Procedure\". When the steel is exposed to elevated temperatures (for example, fire situation) reductions in the strength and deformation properties must be considered. In this sense, the code ABNT/NBR 14432:2000 prescribes values of parameter TRRF (Fire strength required time), with are used for design of steel structures using a simplified method prescribed in ABNT/NBR 14323:1999, or specifying fireproofing. However, this last code doesn\'t prescribe a simplified method for cold-formed steel in fire condition, and the fireproofing materials largely used in Brazil are the sprays, which are not appropriate to cold-formed profiles. In this sense, the main goal of the present work is show a brief context about steel structures in fire conditions, in special cold-formed profiles in room temperature and fire situation, and many types of fire protection materials used in steel structures and its applications. Finally, is suggested a design method to cold-formed profiles in fire, adopting the code ABNT/NBR 14762:2001 \"Design of cold-formed steel structures\", in which appropriate adaptations are considered, as well as a protection procedure to this profiles in fire conditions.
8

Comportamento estrutural e dimensionamento de cantoneiras de aço formadas a frio submetidas à compressão / Structural behavior and design of cold-formed steel angle columns

Enio Carlos Mesacasa Júnior 27 April 2012 (has links)
Envolto ao já conhecido comportamento de cantoneiras esbeltas de abas iguais, questões aparentemente contraditórias tem sido reportadas em estudos experimentais de diversos autores, entre elas a ocorrência de modos de instabilidade em desacordo com aqueles obtidos via análise de estabilidade elástica, e forças axiais resistentes muito diferentes dos resultados teóricos (em geral, conservadoramente). Nestas condições, este trabalho procura analisar a fundo o comportamento das cantoneiras esbeltas de abas iguais, de modo a contribuir com o entendimento dos fenômenos que dificultam a interpretação dos resultados experimentais, dentre os quais, o afastamento longitudinal entre a rótula e a extremidade das barras (no caso de barras com extremidades rotuladas), e o sentido da imperfeição global de flexão em torno do eixo de menor inércia, o qual mostrou-se um fator chave na determinação do comportamento das cantoneiras, especialmente para comprimentos próximos da transição entre os dois modos globais de instabilidade elástica. Para esta faixa de comprimentos, diferentes níveis de interação entre os dois modos globais podem ser obtidos. Ademais, estudos experimentais realizados por diversos autores, aqui complementados por uma série de ensaios realizados em cantoneiras com extremidades engastadas, formam um vasto banco de resultados, que é utilizado para (além de comparações nos estudos teóricos) avaliar diversos procedimentos de previsão teórica sugeridos por diferentes autores, ou advindos de interpretações a partir do procedimento normativo, à luz do comportamento teórico estudado na primeira etapa do trabalho. Assim, destes procedimentos, apenas um baseado no Método da Resistência Direta, e dois baseados no Método das Larguras Efetivas demonstraram bons resultados, sendo que todos eles, desconsiderando o modo de flexo-torção como um modo global de instabilidade. Ao fim, comenta-se da necessidade de se expandir alguns estudos específicos, pois ao adotar-se um procedimento baseado somente no modo global de flexão, apesar de se mostrar estatisticamente mais eficiente, verifica-se a possível ocorrência de resultados demasiadamente contra a segurança. / On the well known behavior of equal-leg angle columns, some questions apparently paradoxical have been reported in experimental results from several authors, including the occurrence of different instability modes from the expected by the elastic stability analysis, and maximum axial compressive load expressly different (generally conservative) from theoretical previsions. Therefore, the aim of this work is to improve the knowledge about the equal-leg angle columns behavior, contributing to the understanding of the features that complicate the interpretation of experimental results, among which, the longitudinal distance between the end sections and the center of hinges (pin-ended columns), and also the direction of the minor-axis flexural initial imperfection, which proved to play a key role in the post-critical column behavior, specially for column lengths near of the transition between global buckling modes (major-axis flexural-torsional and minor-axis flexural modes). On this range of lengths, different modal interaction amplitudes can be obtained, only with the direction of the minor-axis flexural initial imperfection (i.e., the amplitude of this imperfection plays a negligible influence on the column behavior). Furthermore, putting together a fairly large column ultimate strength data bank comprising experimental test results performed by several authors, collected from the available literature, and new experimental results on fixed-ended angle columns performed in this work, important comparisons with theoretical studies can be showed as well as evaluation of several ultimate strength theoretical prevision procedures, either those suggested by another authors as those arising from interpretations of normative procedures in the light of theoretical behavior verified in the first stage of labor. In conclusion, only one procedure based on Direct Strength Method and two procedures based on Effective Width Method exhibited accurate results, all of which neglecting the flexural-torsional mode as a global mode. Thus, it is important to mention that some additional studies are needed, because if adopted a procedure based only in the minor-axis flexural mode, despite being statistically advantageous, it is verified the possibility to occurs quite unconservative results.
9

Ligações metálicas constituídas por parafusos auto-atarraxantes / Steel connections constituted of screws

Márcio Felix de Freitas 01 September 2004 (has links)
O emprego de parafusos auto-atarraxantes em ligações metálicas, nos últimos anos, têm aumentado de forma significativa, principalmente como dispositivo de ligação entre componentes leves da construção metálica, como por exemplo, nas ligações entre telhas metálicas e terças. Tais ligações apresentam modos de falha diferentes dos observados para as ligações parafusadas convencionais, em função do tipo de parafuso e das reduzidas espessuras dos elementos conectados, definidos como \"pull-out\" e \"pull-over\". No Brasil, a carência de estudos específicos nesse tema foi uma das razões da omissão da recente norma brasileira de dimensionamento de estruturas de aço constituídas por perfis formados a frio - NBR 14762:2001, quanto a procedimentos específicos para o projeto de ligações com parafusos auto-atarraxantes. Nesse trabalho foi desenvolvido um estudo abrangente sobre as ligações metálicas com parafusos auto-atarraxantes, com ênfase na ligação telha-terça, onde são apresentados os procedimentos e as recomendações das principais normas estrangeiras, bem como os ensaios padronizados para caracterização dos parafusos e avaliação do comportamento estrutural e resistência de ligações. São apresentados também os resultados de uma investigação experimental, com base no ensaio padrão do AISI (1996) (American Iron and Steel Institute), em 27 corpos-de-prova com variação no diâmetro do parafuso e espessura dos componentes da ligação (terça e telha), com o objetivo principal de avaliar as expressões das AISI (2001b e 1996) para dimensionamento. Como conclusão, são relatadas as dificuldades associadas ao ensaio padrão, que apesar de sua concepção simples, conduz à elevada variabilidade nos resultados, indicando a necessidade da adoção de ensaios mais representativos e confiáveis. / The use of screws in steel connections has increased significantly in recent years, mainly as connecting devices between light-gage components in steel construction, as, for example, in joints between metal roofing and purlins. These connections exhibit different failure modes from those displayed by conventional bolted connections, due to the type of fastener and the reduced thicknesses of the connected elements, defined as pull-out and pull-over. In Brazil, the lack of specific studies of this theme was one of the reasons for the omission of specific procedures for the design of screw connections from the new edition of the brazilian code for cold-formed steel members - NBR 14762:2001. The work reported here involved a comprehensive study of steel connections using screws, with emphasis on the sheating-purlin connection. A presentation is made of the procedures and recommendations of the main foreign codes, as well as of standardized tests for characterizing screws and evaluating the structural behavior and strength of connections. Also presented are the results of an experimental investigation based on the standard test of the AISI (1996) (American Iron and Steel Institute) applied to 27 test specimens with varying screw diameters and connector component thicknesses (purlin and sheeting), whose main purpose was to evaluate the AISI\'s design equations (2001b e 1996). To conclude, a report is made of the difficulties associated with the standard test, which, despite its simple conception, leads to considerably variable results, indicating the need for the adoption of more representative and reliable tests.
10

Recuperação estrutural de edificações históricas utilizando perfis formados a frio / Structural recovery of a historical construction by means of cold-formed sections

Marcos Leopoldo Borges 28 September 2001 (has links)
Este trabalho apresenta a proposta de recuperação estrutural de uma edificação histórica no município de Uberaba por meio de perfis formados a frio. Para o dimensionamento e cálculo dos elementos estruturais foi utilizado o projeto de norma brasileira de dimensionamento de estruturas de aço constituídas por perfis formados a frio. São apresentados os critérios e procedimentos para a recuperação de estruturas em geral e especificamente para as edificações antigas ou históricas. É feita uma análise da viabilidade técnica, da utilização de perfis formados a frio na recuperação estrutural de obras históricas. / This work presents the proposal of structural recovery of a historical construction in Uberaba city, by means of cold-formed sections. It was used the steel structures increasing brazilian norm project, composed of cold-formed sections. It is presented the criteria and procedures for the general structural recovery to the old or historical constructions. It is also made an analysis of technical viability of cold-formed sections utilization in structural recovery of historical works.

Page generated in 0.0647 seconds