1

Analise mecanica e fotoelastica das tecnica de fixação interna rigida da osteotomia sagital utilizando placa convencional e placa com sistema de travamento em avanços mandibulares / Mechanical and photoelastic analysis of two methods of rigid internal fixation in mandfibular advancement

Lyrio, Mariana Camilo Negreiros, 1980- 03 June 2009 (has links)
Orientadores: Marcio de Moraes, Luciana Asprino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T02:18:28Z (GMT). No. of bitstreams: 1 Lyrio_MarianaCamiloNegreiros_M.pdf: 2393437 bytes, checksum: f0dfbf68baaeb080347c83445d15e1e9 (MD5) Previous issue date: 2009 / Resumo: O propósito neste estudo foi realizar avaliação mecânica e fotoelástica de dois diferentes sistemas de fixação interna rígida (FIR): placas convencionais e placas com sistema de travamento. Para avaliação mecânica foi realizado teste de carregamento linear em réplicas de hemimandíbulas humanas dentadas seccionadas na região de ramo mandibular, representando uma osteotomia sagital, e fixadas com avanço mandibular de 5 mm. No grupo I a fixação foi realizada com placas convencionais e parafusos monocorticais do sistema 2,0mm e no grupo II utilizou-se placas e parafusos monocorticais com sistema de travamento do sistema 2,0 mm. Para análise estatística foram aplicados Anova e teste de Tukey em nível de significância de 5%, os quais demonstraram não haver diferenças entre os grupos I e II nos testes mecânicos. Para os testes fotoelásticos foram confeccionadas hemimandíbulas humanas dentadas em resina fotoelástica, também seccionadas simulando a osteotomia sagital e fixadas com avanço mandibular de 5 mm, com os mesmos grupos utilizados para os testes mecânicos. Em relação à distribuição de tensões, pode-se observar que as mesmas se concentram ao redor dos parafusos, principalmente naqueles próximos à área de osteotomia para ambos os grupos. Dessa forma, pode-se afirmar que os sistemas de fixação utilizando placa e parafusos convencionais ou com sistema de travamento não apresentaram diferenças estatísticas quanto à resistência, e que a maior concentração de forças está nas áreas próximas às osteotomias, consideradas regiões de maior fragilidade após a OSRM. / Abstract: The aim of this study was evaluate the mechanical and photoelastic behavior of two methods of rigid internal fixation (RIF): conventional plates and locking plates. For mechanical tests polyurethane synthetic hemimandible with seccional sagittal ramus split was used, simulating an advancement of 5 mm. The fixation performed on the Group I was a 2.0 mm conventional plates with monocortical screws and fixation used on group II was a 2.0 locking plates with monocortical locking screws. Anova and Tukey tests were applied (P<5) and no statistical differences were noted between the groups. Hemimandibles were made in photoelastic resin with same groups used in mechanical tests and submitted to photoelastical analysis. In relation to tension distribution in photoelastic analysis, the fringes were concentrated around screws, mainly in areas near the osteotomy for both groups. Based in this fact, the conventional and locking fixations systems did not present statistical differences on resistence, and the major forces was concentrated in regions near the osteotomies lines, that considered fragility before sagittal split osteotomy. / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
2

Avaliação biomecanica in vitro de tecnicas de fixação rigida metalica para osteotomia sagital do ramo mandibular em movimentos de avanço e recuo / An in vitro biomechanical evaluation of fixation techniques for sagittal split ramus osteotomy in mandibular advancement and setback

Brasileiro, Bernardo Ferreira 26 October 2007 (has links)
Orientador: Luis Augusto Passeri / Tese doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T20:14:50Z (GMT). No. of bitstreams: 1 Brasileiro_BernardoFerreira_D.pdf: 9990302 bytes, checksum: ddce5ea3896243c2b52242b595e7946d (MD5) Previous issue date: 2007 / Resumo: Um melhor entendimento biomecânico da fixação interna rígida (FIR) na osteotomia sagital dos ramos mandibulares (OSRM) pode ser baseado em pesquisas com o intuito de investigar sua função in vitro antes da aplicação clínica. Assim, este trabalho teve como objetivo avaliar comparativamente a resistência de três diferentes técnicas de FIR em réplicas de hemimandíbulas humanas de poliuretano simulando a OSRM para movimentos de 5 mm em avanço e recuo. As técnicas de FIR incluíram uma miniplaca ponte com 4 furos e 4 parafusos monocorticais (grupo miniplaca), uma miniplaca com 4 furos e 4 parafusos monocorticais mais um parafuso bicortical posicional (grupo híbrido) e 3 parafusos bicortical posicionais em configuração em ¿L¿ invertido (grupo ¿L¿ invertido). Os parafusos e as miniplacas utilizados eram de titânio e pertencentes ao sistema de 2,0 mm. Estes foram avaliados quanto à padronização dimensional por meio do coeficiente de variação, que evidenciou alta semelhança macroscópica. As hemimandíbulas foram submetidas a testes de carregamento linear vertical e lateral por uma unidade de testes mecânicos Instron 4411 para registro da carga de pico aos deslocamentos de 1 mm, 3 mm, 5 mm e 10 mm. Médias e desvio padrão foram avaliados aplicando-se a Análise de Variância e o teste de Tukey em nível de significância de 5%. O grupo miniplaca apresentou menores valores de carga de pico ao deslocamento (p<0,01) quando comparada com as outras técnicas de fixação considerando-se igual tipo de movimento e direção de carga. O grupo ¿L¿ invertido foi ainda superior em resistência (p<0,01) ao grupo híbrido em movimento de avanço e com aplicação de carga verticalmente. Concluiu-se que a utilização da técnica de FIR para a OSRM baseada em 3 parafusos bicorticais em ¿L¿ invertido foi a mais estável, e que a colocação de um parafuso bicortical pode otimizar significativamente a resistência da fixação com miniplacas e parafusos monocorticais / Abstract: A better understanding of the biomechanics of sagittal split ramus osteotomy (SSRO) rigid internal fixation (RIF) can be based on research aiming to evaluate its function in vitro before clinical application. Thus, the goal of this investigation was to evaluate comparatively the resistance of three different RIF techniques applied to polyurethane synthetic hemi-mandible replicas simulating the SSRO for 5 mm advancement and setback. RIF techniques included a 4-hole miniplate and 4 monocortical screws (miniplate group), a 4-hole plate and 4 monocortical screws with one additional bicortical positional screw (hybrid group), and 3 bicortical positional screws in a traditional inverted-L pattern (inverted-L group). Screws and miniplates were made of titanium and from 2.0 mm system. These were analyzed according to dimensional standardization by a coefficient of variation, which revealed high macroscopic similarity. The hemi-mandibles were submitted lateral and vertical loading tests in an Instron 4411 mechanical testing unit for recording of peak loading at 1 mm, 3 mm, 5 mm and 10 mm of displacement. Means and standard deviation were analyzed using Analysis of Variance and Tukey test with a 5% level of significance. Miniplate group showed lower load peak scores (p<.01) when compared to the others fixation techniques regarding equal type of movement and force direction. Inverted-L group demonstrated higher resistance (p<.01) than hybrid group during advancement and with application of vertical load. It was concluded the RIF technique for SSRO based on 3 bicortical screws in the inverted-L pattern was the most stable, and the installation of a bicortical screw may significantly optimize the resistance of the miniplate and monocortical screws fixation / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
3

Estudo biomecanico de tres tecnicas diferentes de fixações metalicas utilizadas em osteotomia sagital do ramo mandibular / Biomechanical evaluation of three different techniques of rigid fixation in sagital split ramus osteotomy

Iamashita, Heric Yukio 13 August 2018 (has links)
Orientadores: Valfrido Antonio Pereira Filho, Luis Augusto Passeri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T11:01:55Z (GMT). No. of bitstreams: 1 Iamashita_HericYukio_M.pdf: 10483371 bytes, checksum: 43fabb9ac62869422ae0c9f7b447d409 (MD5) Previous issue date: 2009 / Resumo: Estudos têm proposto diversas técnicas e métodos de fixação interna rígida (FIR) no sentido de se obter maior estabilidade dos segmentos ósseos e mínimo deslocamento condilar após osteotomia sagital do ramo mandibular (OSRM). Desta forma, o presente estudo teve por objetivo avaliar por meio de ensaio mecânico de compressão em hemimandíbulas sintéticas, três diferentes tipos de fixações utilizadas na OSRM em movimento de avanço de 5 mm. Foram utilizadas 30 hemimandíbulas, divididas em 3 grupos com 10 hemimandíbulas em cada. O grupo 1 foi fixado com três parafusos posicionais de 15 mm do sistema 2,0 mm dispostos bicorticalmente na posição de L invertido e com angulação de inserção de 90°; no Grupo 2 a fixação foi realizada com placa de 4 furos do sistema 2,0 mm e 4 parafusos monocorticais de 6 mm de comprimento disposto sobre a região do canal mandibular, e o Grupo 3 a fixação consistiu de uma placa sagital ajustável do sistema 2,0 mm e 8 parafusos de 6,0 mm de comprimento também localizada sobre o canal mandibular. Sendo avaliados quanto à padronização, o sistema de fixação demonstrou semelhança dimensional. As hemimandíbulas foram submetidas a cargas compressivas verticais, por meio de ponta de aplicação de carga em máquina de ensaio universal MTS®, na velocidade de 1 mm/min com deslocamento máximo de 10 mm. Médias e desvios padrão foram obtidos e submetidos à análise de variância a um fator e teste HSD de Tukey com nível de significância de 5%. O Grupo 1 apresentou maiores valores de resistência à força de carga compressiva (p<0,001) sendo superior aos demais grupos. O Grupo 3 demonstrou a menor resistência às forças (p<0,001). Concluiuse que o uso de parafusos bicorticais posicionais em L invertido promove a maior capacidade de resistência às cargas compressivas, sendo que as placas sagitais ajustáveis apresentam-se cerca de 60% menos resistentes do que o Grupo 1. / Abstract: Studies have considered many techniques and methods of rigid internal fixation (RIF) leads to obtain greater stability to the bone segments and minimum displacement of the condyles after performed the sagittal split ramus osteotomy (SSRO). In this way, the purpose of this study was to evaluate by means of mechanical compression testing model with synthetic hemimandibles, three different fixation types used in the SSRO in movement of advance of 5 mm. Thirty hemimandibles, divided in 3 groups with 10 hemimandibles in each group. Group 1 was fixed with three 15 mm positional screws (2.0 mm diameter) bicortically in an inverted-L pattern and with insertion angle of 90°; in Group 2 the fixation was carried through with four-hole straight plate and four 6 mm monocortical screws made located on the region of the mandibular canal, and Group 3 the fixation is consisted of an adjustable sagittal plate and eight 6 mm screws also placed on the mandibular canal. Evaluated for dimensional standardization, the fixation system had demonstrated dimensional similarity. Hemimandibles had been exposed to the vertical compressive loads, by means of tip of load application in a MTS® mechanical testing unit, in the speed of 1 mm/min with maximum displacement of 10 mm. Averages and standard deviations had been obtained and submitted to the analysis of variance to a factor and have tested for HSD of Tukey test with a 5% level of significance. Group 1 presented greaters values of resistance to the compressive loads (p< 0.001) showed superior to the other groups. Group 3 demonstrated the lesser resistance to the loading forces (p< 0.001). It was concluded that the use of positional bicortical screws in inverted-L pattern promotes the higher capacities of resistance to compressive loads, moreover, the adjustable sagittal plates are presented about less resistant 60% that the Group 1. / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
4

Resistência de três tipos de fixação utilizados no tratamento das fraturas do ângulo mandibular / Resistance of three types of fixation in the treatment of fractures of the mandibular angle

Cavalieri-Pereira, Lucas, 1982- 08 January 2012 (has links)
Orientadores: Alexandre Elias Trivellato, Marcio de Moraes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T07:03:24Z (GMT). No. of bitstreams: 1 Cavalieri-Pereira_Lucas_D.pdf: 1578055 bytes, checksum: 8c7fc995f3dac6a8d0d45c1bc49f3175 (MD5) Previous issue date: 2012 / Resumo: Fraturas do ângulo mandibular são muito freqüentes dentre as fraturas mandibulares e um das formas de tratamento é a utilização de fixação interna com placas e parafusos. Neste estudo o objetivo foi avaliar comparativamente a resistência de três tipos de fixação em réplicas de mandíbula de poliuretano, empregando-se a técnica de Champy. Foram utilizadas 63 mandíbulas dentadas, submetidas aa seccionamento simulando uma fratura linear e favorável de ângulo mandibular esquerdo. As fixações foram realizadas com placas retas do sistema 2,0 mm, dispostas da seguinte forma: uma placa com quatro furos, uma com cinco furos e uma com quatro furos e extensão (ponte). A estabilização e fixação foram realizadas com adaptação da placa e quatro parafusos de 6,0 mm de comprimento, sobre a linha oblíqua da mandíbula. Foram elaborados 9 grupos, com 7 mandíbulas cada um, sendo 3 grupos fixados com placa de 5 furos, 3 com placa reta de 4 furos com extensão e 3 com placa reta de 4 furos. Cada conjunto foi submetido ao teste de carregamento linear com aplicação de carga no sentido súpero-inferior em três pontos distintos da mandíbula, de modo não simultâneo (região de molar ipsilateral à secção, incisivos centrais e molar contralateral) em máquina de ensaio universal EMIC DL 2000. Foram mensurados valores de carga no deslocamento de 1 mm, 2 mm e final e anotado o deslocamento final. Os resultados obtidos foram submetidos à análise estatística, utilizando a análise de variância (ANOVA), seguido do teste de Tukey, nível de significância de 5%. Nos valores de cargas obtidos, tanto quando aplicada no molar ipsilateral ao seccionamento, no molar contralateral ao seccionamento e entre incisivos centrais, foi verificada diferença estatística somente no momento do deslocamento final, na qual a placa com 5 furos e com 4 com extensão foi superior a placa com quatro furos. Não houve diferença entre placa com 5 furos e com 4 com extensão / Abstract: Mandibular angle fractures are very frequent among the mandibular fractures and a form of treatment is the use of internal fixation with plates and screws. In this study, the objective was to evaluate the resistance of three types of fixation in mandibular replicas of polyurethane, using the technique of Champy. Sixty three toothed mandibles were used, subject to sectioning simulating a linear and favorable fracture of left mandibular angle. The fixations were performed with straight plates system 2.0 mm, prepared as follows: one plate with 4-holes, one with 5-holes and one 4-holes and extension (bridge). Stabilization and adjustment were performed with locking plate and four screws of 6.0 mm in length, about the oblique line of the mandible. Nine groups were elaborated, with 7 each, which 3 groups being fixed with 5-holes plates, 3 groups with 4-holes plates with extension and 3 groups with 4-holes plates. Each set was submitted for loading test with load application towards in three distinct points of the mandible, so do not simultaneously (molar region on the side ipsilateral of section, the central incisors and contralateral molar) in universal testing machine EMIC DL 2000. Load values were measured at offset 1 mm, 2 mm and final and was noted the final dislocation. The results were submitted to statistical analysis, using analysis of variance (ANOVA) followed by Tukey test, a significance level of 5%. The values obtained, when loads were applied in the ipsilateral molar, contralateral molar and incisors, was verified statistically only at the final dislocation, in which the 5-holes plates and 4-holes with extension was more resistant than 4-holes plates. There was no difference between plate with 5-holes and 4-holes with extension / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
5

Comparação biomecânica entre CRIF e placa de reconstrução utilizadas para estabilização de fraturas distais de fêmur de cães / Biomechanical comparison of CRIF and reconstruction plate for stabilization of distal femur fractures in dogs

Paes, Fernanda 25 October 2016 (has links)
O presente estudo objetivou comparar biomecanicamente, por meio do ensaio de compressão excêntrica, a resistência dos implantes Clamp and Rod Internal Fixation (CRIF) 5,0 mm versus placa de reconstrução 3,5 mm na fixação de fratura distais de fêmur de cão. Tais implantes foram subdividos em dois grupos, denominados grupo CRIF (GC) e grupo placa (GC). Foram utilizados 22 fêmures de 10 cadáveres de cão entre 2 e 7 anos de idade e peso corporal entre 20 e 40 kg, que foram distribuídos aleatoriamente a serem testados ambos os implantes em cada um dos membros dos pares. Para realização dos testes, foi simulado uma fratura distal nos corpos de prova, através de uma osteotomia de até 0,5 cm, realizada por meio de serra oscilatória, imediatamente proximal ao início da tróclea. Os implantes foram fixados segundo os padrões AOSIF, lateralmente ao fêmur, sendo utilizados três parafusos distais e cinco proximais ao foco de fratura. Foi utilizado o programa de computador PMI para calcular o ponto máximo de resistência antes da falha e avaliadas as variáveis força máxima, deformação máxima real, rigidez, força intermediária e deformação intermediária real. Não foram encontradas diferenças estatisticamente significativas entre os GC e GP quantos as variáveis avaliadas / This study aims to compare the biomechanical properties, through eccentric compression test, of the resistance of the 5.0 mm Clamp and Rod Internal Fixation Implants (CRIF) and 3.5 mm reconstruction plate in fixing dog femur distal fracture. Such implants were subdivided into two groups, called CRIF Group (CG) and plate group (CG). It was used 22 femurs from 11 dog cadavers with age between 2 and 7 years old and body weight between 20 and 40 kg, which was randomly assigned to test both implants in each member of the pair. A distal fracture in the specimens with a gap of 0.5 cm osteotomy, it was simulated to perform the test, performed by the oscillating saw, just proximal to the beginning of the trochlea. Bound the distance from the gap to the distal femur limit was equivalent to the distance between the femoral condyles. The implants were fixed by the standards AO / SIF, laterally to the femur, being used three distal screws and five proximal to the fracture site. The bone was placed longitudinally, and the femoral neck coupled to a concave surface simulating an acetabular device. PMI computer program was used to calculate the maximum point of resistance before failure and evaluated the variables maximum strength, real maximum deformation, stiffness, intermediate strength and real intermediate deformation. No statistically significant differences were found between the GC and GP as the variables evaluated
6

Avaliação in vitro da resistência de três tipos de fixação para tratamento de fraturas de ângulo mandibular / In vitro evaluation of the resistance of 3 types of fixation for treatment of mandibular angle fractures

González, Diana Maritza Contreras 18 March 2015 (has links)
As fraturas do ângulo mandibular são muito frequentes dentre as fraturas mandibulares e um das formas de tratamento é a utilização de fixação interna com placas e parafusos. Neste estudo o objetivo foi avaliar comparativamente a resistência de três tipos de fixação em réplicas de mandíbula de poliuretano. Foram utilizadas 63 mandíbulas dentadas, submetidas a seccionamento simulando uma fratura linear e desfavorável de ângulo mandibular esquerdo. As fixações foram realizadas com placas do sistema 2,0 mm, dispostas da seguinte forma: uma placa reta de quatro furos, uma placa reta de quatro furos com extensão (ponte) e uma placa 3D 4 furos. Cada grupo (n = 21) foi submetido ao teste de resistência linear com aplicação de carga no sentido súpero-inferior em três pontos distintos da mandíbula, de modo não simultâneo (região do primeiro molar ipsilateral à secção, primeiro molar contralateral e incisivos centrais) em máquina de ensaio universal EMIC DL 2000. Foram mensurados valores de carga no deslocamento de 1 mm, 2 mm e 5mm. Os resultados obtidos foram submetidos à análise estatística, utilizando a análise de variância (ANOVA), nível de significância de 5%. Os valores obtidos, não apresentaram diferença estatisticamente significante entre as placas. Os resultados mostraram que as placas 3D produzem escores similares às placas usadas convencionalmente. Com base nos resultados obtidos, pode-se concluir que os três tipos de fixação se comportam de forma similar. / Mandibular angle fractures are very frequent among the mandibular fractures and a form of treatment is the use of internal fixation with plates and screws. In this study, the objective was to evaluate the resistance of three types of fixation in mandibular replicas of polyurethane. Sixty three toothed mandibles were used, subject to sectioning simulating a linear and unfavorable fracture of left mandibular angle. The fixations were performed with straight plates system 2.0 mm, prepared as follows: one plate with 4-holes, one 4-holes and extension (bridge) and one plate 3D 4-holes .Each set was submitted for loading test with load application towards in three distinct points of the mandible, so do not simultaneously (molar region on the side ipsilateral of section, the central incisors and contralateral molar) in universal testing machine EMIC DL 2000. Load values were measured at offset 1 mm, 2 mm and 5mm and was noted the final dislocation. The results were submitted to statistical analysis, using analysis of variance (ANOVA), a significance level of 5%. the values obtained showed no statistically significant difference between the plates. The results show that the 3D plate can reproduce similar mechanical scores to the plates used conventionally. It can be concluded that the three types of fasteners behaved similarly.
7

Avaliação in vitro do uso de uma miniplaca convencional e locking, de 4 e 7 furos, para tratamento das fraturas de ângulo mandibular

Ribeiro Júnior, Paulo Domingos [UNESP] 06 May 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-05-06Bitstream added on 2014-06-13T19:20:06Z : No. of bitstreams: 1 ribeirojunior_pd_dr_araca.pdf: 475855 bytes, checksum: 25027ddf9644c9757d0a760d4ed4ca58 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este estudo avaliou in vitro a influência do tipo de miniplaca (convencional ou locking) e do número de parafusos instalados no segmento ósseo distal e proximal para a promoção da estabilidade óssea e resistência da osteossínteses pelo método Champy, utilizada para o tratamento de fraturas de ângulo mandibular. Sessenta hemi-mandíbulas de poliuretano, com consistência similar ao osso mandibular, foram divididas em 4 grupos (n=15) e seccionadas na região de ângulo mandibular simulando uma fratura. Os segmentos ósseos foram fixados por diferentes tipos de miniplacas usando sistema 2.0- mm e parafusos monocorticais de 2.0 x 6.0mm. Nos grupos 1 e 2, dois parafusos convencionais (G1) ou locking (G2) foram instalados em cada segmento ósseo usando respectivamente miniplacas retas convencionais e locking; Nos grupos 3 e 4, três parafusos convencionais (G3) ou locking (G4) foram instados no segmento ósseo proximal e quatro parafusos convencionais (G3) ou locking (G4) foram instalados no segmento distal, usando uma miniplaca convencional (G3) e locking (G4) de sete furos, reta. As hemi-mandíbulas foram submetidas a um teste de compressão utilizando uma máquina universal de ensaio INSTRON até que houvesse um distanciamento entre os segmentos ósseos de 4 mm, seja no sentido horizontal ou vertical. Os dados registrados foram submetidos à avaliação estatística pelo método ANOVA e teste de Tukey utilizando um nível de significância de 1%. As miniplacas locking ofereceram maior resistência ao teste de compressão do que as miniplacas convencionais (p<0.01). Porém, não existiu diferença entre o uso de miniplacas de 7 ou 4 furos (p>0.01). Apesar de não estatisticamente significante os resultados numéricos sugeriram que as miniplacas locking longas oferecem maior resistência ao teste de compressão que as miniplacas locking curtas. / This study evaluated in vitro the influence of the type of miniplate (conventional or locking) and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy’s osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to 4 groups (n=15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplates and 2.0 x 6 mm monocortical screws: Groups 1 and 2- Two conventional (G1) or locking (G2) screws were installed in each bone segment using either a conventional (G1) or a locking (G2) straight miniplate; Groups 3 and 4- Three conventional (G3) or locking (G4) screws were installed in the proximal segment and four conventional (G3) or locking (G4) screws were installed in the distal segment using a either a conventional (G3) or a locking (G4) 7-hole straight miniplate. The hemimandibles were loaded in compressive strength in an Instron machine until a 4-mm displacement occurred between the segments either vertically or horizontally. Data were analyzed statistically by ANOVA and Tukey’s test at 1% significance level. The locking plate/screw systems provided significantly greater resistance to displacement under compressive load than the conventional plate/screw systems (p<0.01). However, no statistically significant difference was found between 7-hole and 4-hole miniplates (p>0.01). In conclusion, the locking miniplates offered more resistance than conventional miniplates and long locking miniplates provided greater (number results) bone stability compared to short ones.
8

Avaliação mecânica de seis formas de fixação interna da osteotomia sagital do ramo mandibular, em movimento de avanço com rotação anti-horária /

Oliveira, Leandro Benetti de. January 2016 (has links)
Orientador: Marisa Aparecida Cabrini Gabrielli / Banca: Luis Geraldo Vaz / Banca: Eduardo Hochuli Vieira / Banca: Alexandre Elias Trivelato / Banca: Luciana Asprino / Resumo: Este estudo avaliou a resistência ao deslocamento vertical de seis métodos de fixação interna estáveis utilizados na osteotomia sagital do ramo mandibular (OSRM) no movimento de avanço mandibular com rotação anti-horária. Foram utilizadas sessenta hemimandíbulas sintéticas, divididas em seis grupos de 10 hemimandíbulas, todas fixadas com sistema de fixação 2,0 mm da seguinte forma: Grupo I - 1 miniplaca reta de quatro furos e quatro parafusos monocorticais de 6,0 mm; Grupo II - 1 miniplaca reta de seis furos e seis parafusos monocorticais de 6,0 mm; Grupo III - 2 miniplacas retas de quatro furos e oito parafusos monocorticais de 6,0 mm; Grupo IV - 1 placa grade de oito furos e oito parafusos monocorticais de 6,0 mm; Grupo V - 1 miniplaca reta de quatro furos com quatro parafusos monocorticais de 6,0 mm e um parafuso bicortical 2,0 x 12 mm; Grupo VI - 1 miniplaca reta de quatro furos, locking e quatro parafusos monocorticais de 6,0 mm locking. O teste mecânico foi realizado por meio da aplicação de uma força linear na região entre o primeiro pré-molar e canino, em uma máquina de ensaios mecânicos (EMIC- DL2000) com célula de carga de 10 kilogramas Newton (kN). As cargas para o deslocamento de 1, 3 e 5 mm foram registados em Newton (N) e os dados foram transmitidos para um computador. Os resultados foram avaliados utilizando a análise de variância ANOVA (p <0,001) e teste de Tukey para comparação entre os grupos. O sistema de fixação testado nas três condições de deslocamento m... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the resistance to vertical displacement of six stable fixation methods for the sagittal split ramus osteotomy (SSRO) in the mandibular advancement with counterclockwise rotation. Sixty synthetic hemimandibles were used. They were divided into six groups of 10 hemimandibles, all hemimandibles were fixed with 2.0 mm system as follows: Group I - fixation with a straight four-hole miniplate and four monocortical screws 6.0 mm; Group II - a straight six-hole miniplate and six monocortical screws 6.0 mm; Group III - two straight four-hole miniplates and eight monocortical screws 6.0 mm; Group IV - an eight-hole (grid plate) and eight monocortical screws 6.0 mm; Group V - a four-hole straight miniplate with four monocortical screws 6.0 mm and 2.0 x 12 mm bicortical screw; Group VI - a straight four-hole locking miniplate and four monocortical screws locking 6.0 mm. Biomechanical evaluation was performed by applying a linear force in the region between the canine and first premolar, using a mechanical testing machine (EMIC- DL2000) with loading cell of 10 kN. The loads at 1, 3 and 5 mm of displacement were recorded in N and the data were transmitted from the load cell to a computer. Results were analyzed using the variance analysis ANOVA (p < 0.001) and Tukey post-test for comparison between the groups. For the three displacement conditions fixation with two straight 2.0 mm plates and with the grid plate presented higher load values. / Doutor
9

Avaliação in vitro da resistência de três tipos de fixação para tratamento de fraturas de ângulo mandibular / In vitro evaluation of the resistance of 3 types of fixation for treatment of mandibular angle fractures

Diana Maritza Contreras González 18 March 2015 (has links)
As fraturas do ângulo mandibular são muito frequentes dentre as fraturas mandibulares e um das formas de tratamento é a utilização de fixação interna com placas e parafusos. Neste estudo o objetivo foi avaliar comparativamente a resistência de três tipos de fixação em réplicas de mandíbula de poliuretano. Foram utilizadas 63 mandíbulas dentadas, submetidas a seccionamento simulando uma fratura linear e desfavorável de ângulo mandibular esquerdo. As fixações foram realizadas com placas do sistema 2,0 mm, dispostas da seguinte forma: uma placa reta de quatro furos, uma placa reta de quatro furos com extensão (ponte) e uma placa 3D 4 furos. Cada grupo (n = 21) foi submetido ao teste de resistência linear com aplicação de carga no sentido súpero-inferior em três pontos distintos da mandíbula, de modo não simultâneo (região do primeiro molar ipsilateral à secção, primeiro molar contralateral e incisivos centrais) em máquina de ensaio universal EMIC DL 2000. Foram mensurados valores de carga no deslocamento de 1 mm, 2 mm e 5mm. Os resultados obtidos foram submetidos à análise estatística, utilizando a análise de variância (ANOVA), nível de significância de 5%. Os valores obtidos, não apresentaram diferença estatisticamente significante entre as placas. Os resultados mostraram que as placas 3D produzem escores similares às placas usadas convencionalmente. Com base nos resultados obtidos, pode-se concluir que os três tipos de fixação se comportam de forma similar. / Mandibular angle fractures are very frequent among the mandibular fractures and a form of treatment is the use of internal fixation with plates and screws. In this study, the objective was to evaluate the resistance of three types of fixation in mandibular replicas of polyurethane. Sixty three toothed mandibles were used, subject to sectioning simulating a linear and unfavorable fracture of left mandibular angle. The fixations were performed with straight plates system 2.0 mm, prepared as follows: one plate with 4-holes, one 4-holes and extension (bridge) and one plate 3D 4-holes .Each set was submitted for loading test with load application towards in three distinct points of the mandible, so do not simultaneously (molar region on the side ipsilateral of section, the central incisors and contralateral molar) in universal testing machine EMIC DL 2000. Load values were measured at offset 1 mm, 2 mm and 5mm and was noted the final dislocation. The results were submitted to statistical analysis, using analysis of variance (ANOVA), a significance level of 5%. the values obtained showed no statistically significant difference between the plates. The results show that the 3D plate can reproduce similar mechanical scores to the plates used conventionally. It can be concluded that the three types of fasteners behaved similarly.
10

Desenvolvimento e propriedades mecânicas da placa óssea bloqueada em formato T /

Mesquita, Luciane dos Reis. January 2015 (has links)
Orientador: Sheila Canevese Rahal / Banca: Cláudia Valéria Seullner Brandão / Banca: Maria Jaqueline Mamprim / Banca: Fernanda De Biasi / Banca: Bruno Watanabe Minto / Resumo: O objetivo do estudo foi desenvolver uma placa óssea bloqueada em formato de T, com o intuito de ser utilizada em fraturas distais de rádio, e avaliar a resistência da montagem, por meio de ensaios mecânicos. A placa de 2,7 mm foi confeccionada em titânio, contendo eixo com três orifícios para parafusos bloqueados e um orifício para compressão dinâmica, e uma cabeça com dois orifícios para parafusos bloqueados. A cabeça da placa possuía uma chanfradura localizada na porção médio-distal e a extremidade proximal da haste da placa apresentava formato afunilado. Para os ensaios mecânicos foram usados 40 corpos de prova sintéticos em formato de T e 20 placas em T. A placa óssea foi posicionada sobre os corpos de prova, com a falha óssea segmentar de 2 mm localizada entre a cabeça e a haste da placa. Para a determinação das cargas para os ensaios de fadiga, seis montagens foram testadas até a falha, sendo três em flexão engastada e três em compressão. Para o ensaio de fadiga foram utilizadas 14 montagens, sendo sete testadas em compressão axial e sete em flexão engastada. Em ambos os ensaios foram observados valores mais altos, em todas as variáveis avaliadas, na configuração sob carga axial do que na flexão engastada. Além disso, no ensaio em fadiga em compressão axial as montagens suportaram um maior número de ciclos. Foi possível concluir que pelos testes mecânicos, o modelo oferece suficiente estabilidade para resistir as cargas axiais no tratamento de fratura radial distal / Abstract: The aim of this study was to develop a locked T-plate to be used in distal radial fractures and evaluate the mechanical properties. A titanium 2.7 mm T-plate was designed with a shaft containing three locked screw holes and one dynamic compression hole, and a head with two locked screw holes. The head of the plate had an indentation and shaft had tapered-shaped end. Forty polyurethane blocks having a T-shaped and 20 titanium T-plates were used for mechanical testing. The bone plate was positioned over the polyurethane blocks with 2 mm fracture gap between the head and shaft of the plate. Six bone-plate constructs were tested until failure, three in axial compression and three in cantilever bending, to determine the loads for fatigue testing. Fourteen bone-plate constructs were tested for failure in fatigue, seven in axial compression and seven in cantilever bending. Fatigue failure was defined as polyurethane block breakage or pullout of the screws in the polyurethane block. Tests were discontinued after one million cycles if the construct had not already failed. In both static and fatigue testing, higher values of axial compression test than cantilever bending test were observed for all variables. Moreover, the constructs under fatigue axial compression test supported a larger number of cycles to failure. The locking Tplate tested has biomechanical properties that may offer sufficient stability to resist axial loads in the treatment of a distal radius fracture / Doutor