Spelling suggestions: "subject:"placas ósseas"" "subject:"placas osseas""
21 |
Estudo comparativo da resistência mecânica cíclica e linear entre placas pré-dobradas e dobradas manualmente para avanço maxilar em cirurgia ortognática / Comparative study of cyclic and linear mechanical resistance of prebent and manually bent plates used for maxillary advancement in orthognathic surgeryMoura, Andrezza Lauria de, 1982- 25 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-25T11:10:00Z (GMT). No. of bitstreams: 1
Moura_AndrezzaLauriade_D.pdf: 2051584 bytes, checksum: 4113d876cae0533f95488619a05aa704 (MD5)
Previous issue date: 2014 / Resumo: O propósito no estudo foi avaliar comparativamente, através de teste de carregamento linear e cíclico, placas pré-dobradas e dobradas manualmente para avanço maxilar em cirurgia ortognática. Os grupos foram divididos em: Grupo I com placas pré-dobradas para avanço maxilar de 5mm, fixadas em blocos de poliuretano para o teste linear e blocos de alumínio para o teste cíclico; e grupo II, com placas dobradas manualmente simulando avanço maxilar de 5mm, fixadas em blocos de poliuretano e alumínio. Os testes de carregamento linear foram realizados com 8 amostras em cada grupo e com auxílio da máquina para ensaio universal mecânica Instron® 4411 até a falha do material. Já o teste cíclico foi realizado com 5 amostras em cada grupo através de uma máquina para ensaio universal Instron® E3000 e foram submetidas à carga de 12N a 120N, frequência de 3 Hz até a fratura da placa ou parafuso e com o número máximo de 500.000 ciclos. As médias e desvio padrão foram avaliadas através dos testes t-Student e Mann-Whitney em nível de significância de 5% para o teste linear e medianas através do teste Mann-Whitney para o teste cíclico. Os resultados do teste mecânico linear mostraram que não houve diferença estatística entre os grupos de placas pré-dobradas e dobradas manualmente, quando comparados em relação a carga de pico (p=0.09) e deslocamento de pico (p=0.63). Já o teste cíclico apresentou diferença estatística entre os grupos quanto ao número de ciclos, onde o grupo de placas pré-dobradas atingiu o limite de 500.000 ciclos sem fratura e o grupo de placas dobradas manualmente fraturaram em uma média 94.737 ciclos (p=0.008). A resistência mecânica in vitro entre os grupos de placas pré-dobradas e as dobradas manualmente não alterou com a confecção de dobras no teste de carregamento linear, porém, a confecção das mesmas pode ter criado microfraturas e fragilizações que, com o teste de ciclagem, causaram fratura prematura das placas com dobras manuais / Abstract: The purpose of the study was to comparatively evaluate, through linear load testing and cyclic loading test, prebent plates and plates bent manually to maxillary advancement in orthognathic surgery. The groups were divided into Group I with prebent plates for 5mm maxillary advancement, fixed in polyurethane blocks for linear test and aluminum blocks for cyclic test; and group II, with eight plates bent manually for 5mm maxillary advancement, fixed in polyurethane and aluminum blocks. Linear loading tests were performed with eight samples in each group through a mechanical universal testing machine Instron ® 4411, until failure of the material. The cyclic tests were performed with five samples in each group through a mechanical universal testing machine Instron ® E3000, where the samples were subjected to load of 12N to 120N and frequency of 3 Hz until plate or screw fracture, whit maximum number of 500,000 cycles. Means and standard deviations were evaluated by applying the Student t test and Mann-Whitney test at a significance level of 5% for linear loading and medians by Mann-Whitney test for cyclic loading. The results of linear mechanical testing showed no statistical difference between the groups pre-folded cards and folded manually compared peak load (p = 0.09) and peak displacement (p = 0.63). The cyclic test showed statistical difference between the groups, where the group of prebent plates reached the limit of 500,000 cycles without fracture and the group of manual bent plates fractured at an average of 94.737 cycles (p=0.008). The mechanical resistance in vitro among groups of prebent plates and plates bent manually does not change with the confection of bends in the linear loading test; however, the bends may have created microfractures and embrittlements that with the cyclic test, caused premature fracture of the plates / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutora em Clínica Odontológica
|
22 |
Avaliação mecânica in vitro e análise fractográfica de duas marcas comerciais nacionais de sistema de fixação 2,0mm com travamento de parafusos em fraturas simuladas de corpo mandibular / Mechanical and fractographic analysis of two national brands of 2.0mm locking fixation systems in simulated mandibular body fractureCorreia Medeiros, Raquel, 1986- 23 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T02:59:43Z (GMT). No. of bitstreams: 1
CorreiaMedeiros_Raquel_M.pdf: 1506622 bytes, checksum: 7e7760f3ed374300679a2cb781f5ca71 (MD5)
Previous issue date: 2013 / Resumo: Este trabalho teve como objetivo de avaliar comparativamente a resistência de duas marcas de sistema de fixação de 2,0 mm com sistema de travamento de parafusos em hemimandíbulas de alumínio com fratura simulada de corpo mandibular. E também, realizar a análise fractográfica das placas utilizadas no estudo acima, através de Microscopia Eletrônica de Varredura (MEV). Quatro hemimandíbulas em alumínio com seccionamento linear simulando uma fratura de corpo mandibular foram utilizadas como substrato, fixadas de acordo com duas técnicas de fixação de duas marcas nacionais Tóride® (Tóride Indústria e Comércio Ltda. - Mogi Mirim, São Paulo - Brasil) e Traumec® (Traumec - Tecnologia e Implantes Ortopédicos Imp. e Exp. Ltda.- Rio Claro, São Paulo- Brasil) e divididas em dois grupos. O grupo I foi fixado com uma placa de quatros furos, com quatro parafusos de 6 mm na zona de tensão e uma placa de 4 furos, com 4 parafusos de 10 mm na zona de compressão e o grupo II foi fixado com uma placa de 4 furos com 4 parafusos de 6 mm na zona neutra. Para cada grupo foram utilizadas cinco amostras de cada marca comercial. As hemimandíbulas foram submetidas a testes de carregamento linear vertical por uma unidade de testes mecânicos Instron 4411(Instron Corp, Norwood, MA) para registro da carga de pico e da carga nos deslocamentos de 3 mm, 5 mm e 7 mm. As médias e o desvio padrão foram avaliados aplicando-se a Análise de Variância em nível de significância de 5%. Após os testes mecânicos, não houve diferença estatisticamente significante entre as marcas, tanto no grupo I quanto no grupo II, em relação às cargas suportadas no deslocamento de 3 mm e 5mm, nem entre as cargas de pico, havendo diferença apenas no deslocamento de 7 mm. De uma maneira geral, as placas Tóride® suportaram uma carga maior nos dois grupos. A superfície de fratura analisada no MEV apontou para uma fratura do tipo dúctil, normalmente encontrada em corpos de ensaio de tração de materiais dúcteis, como o titânio. Não foram observados em nenhuma superfície de fratura quaisquer indícios de falha por alteração na estrutura ou na composição do material / Abstract: This study aimed to comparatively evaluate the resistance of two brands of rigid fixation system with 2,0 mm locking system in hemimandibles of aluminum with simulated fracture of the mandibular body. Also, perform fractographic analysis of the same, by Scanning Electron Microscopy (SEM). Four hemimandible of aluminum with a sectioning linear simulating fracture of mandibular body were used as substrate and fixed according to two techniques for two national brands Tóride® (Tóride Indústria e Comércio Ltda. - Mogi Mirim, São Paulo - Brazil) and Traumec® (Traumec - Orthopedic Implants and Technology Imp. e Exp Ltda. - Rio Claro, São Paulo, Brazil). The techniques were: two 4- hole locking miniplate applied at the superior and inferior borders and one 4-hole locking miniplate applied in neutral zone. The samples was subjected to linear vertical loading in the canine region in an mechanical testing unit Instron 4411 (Instron Corporation, Norwood, MA) and the peak load and load displacement in 3 mm, 5 mm and 7 mm were recorded. Averages and standard deviations were evaluated by applying the analysis of variance at a significance level of 5%.After mechanical testing, there was no statistically significant difference between the brands, both in group I and group II, in relation to the load supported in the displacement of 3 mm and 5 mm, or between peak loads. The only difference between the brands, for both groups, was the load in the displacement of 7 mm. In general, the plates Toride supported a greater load in both groups. The fracture surface examined under SEM indicated a ductile fracture, usually found in bodies testing of ductile materials such as titanium. Were not observed, in any fracture surface, any evidence of failure by altering the structure or composition of the material / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestra em Clínica Odontológica
|
23 |
Análise da resistência mecânica e fractográfica de placas de titânio do sistema 1,5mm e dois métodos de fixação em fraturas simuladas em corpo de hemimandíbula de alumínio / Mechanical and fractographic analysis of 1,5mm titanium platesin two methods of fixation in simulated body fractures of aluminum hemimandiblesRodrigues, Danillo Costa, 1981- 23 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T17:35:55Z (GMT). No. of bitstreams: 1
Rodrigues_DanilloCosta_M.pdf: 1685806 bytes, checksum: 0e90fd8fb32a562bcf7161f1f78bfab7 (MD5)
Previous issue date: 2013 / Resumo: O presente estudo teve como propósito analisar a resistência mecânica de duas marcas de fixação do sistema 1,5mm através de teste mecânico de carregamento linear em dois métodos de fixação em modelos de hemimandíbulas de alumínio com fraturas simuladas e realizar análise fractográfica. Foi realizada a confecção de quatro estruturas de alumínio semelhantes a hemimandíbula, sendo utilizada duas hemimandíbulas para cada grupo de estudo. As mesmas foram fixadas com placas e parafusos das marcas Tóride® e Traumec®. No grupo I foi empregada uma placa reta de titânio de quatro furos na zona de compressão e outra na zona de tensão mandíbular; e no grupo II, foi empregada apenas uma placa reta de quatro furos na zona neutra. Para os testes mecânicos, foi utilizada a máquina para ensaio universal mecânica Instron® modelo 4411 até ocorrer a falha total do sistema de fixação (fratura da placa). Em seguida, as amostras foram submetidas a análises fractográficas das superfícies fraturadas com microscópio eletrônico de varredura FEI®. Foi aplicada a Análise de Variância (ANOVA) dois fatores e o teste de Tukey com significância de 5%. A fixação com duas placas retas de quatro furos apresentou maior resistência à carga (p<0,01) em relação ao grupo de apenas uma placa, independente da marca comercial. A marca Tóride® apresentou média de deslocamento de pico maior que as placas Traumec® quando avaliadas nos grupos com uma placa e extensão de carga no deslocamento de 5mm. As amostras romperam por sobrecarga dúctil, por falha mecânica caracterizada por dano alveolar / Abstract: The purpose of this study was to analyze the mechanical strength of two brands of 1.5 mm system fixation through mechanical linear load test in two fixation methods in aluminum hemimandibles with simulated body fractures and perform fractographic analysis of the samples. Four aluminum structures similar to hemimandibles were fabricated with a linear sectioning simulating a fracture of mandibular body and two hemimandibles were used in each group for posterior fixation with plates and screws with two national brands: Toride® and Traumec®. The group I was fixed with a straight titanium plate with four holes in the compression zone and another one in the tension zone. Group II was fixed with a straight plate with four holes in the neutral zone. For mechanical testing, a universal mechanical testing Instron ® Model 4411 was used and the test was made until final failure of the system (fracture plate). Then, the samples were submitted to fractographic analysis through a scanning electron microscope FEI ®. A analysis of variance (ANOVA) Two-way and Tukey test with 5% significance (?= .05) were applied for statistical analysis. The fixation method with two straight plates showed a higher load resistance (p<0.01) when compared to the group of only one plate, regardless of the brand. The brand Toride® showed an average of peak displacement higher than Traumec® when the groups with only one plate with the extension of 5mm were evaluated. All the samples fractured by ductile overload, characterized by alveolar micromechanisms / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
|
24 |
Comparação entre métodos de fixação interna utilizadas no tratamento de fraturas do ângulo mandibular = estudo mecânico / Comparison of internal fixation methods in the management of mandibular angle fractures : mechanical studyLyrio, Mariana Camilo Negreiros, 1980- 06 October 2011 (has links)
Orientadores: Valfrido Antonio Pereira Filho, Marcio de Moraes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T20:34:21Z (GMT). No. of bitstreams: 1
Lyrio_MarianaCamiloNegreiros_D.pdf: 27352279 bytes, checksum: c9fcc8fa65410e2e71a94c3f054de2c6 (MD5)
Previous issue date: 2011 / Resumo: Apesar dos diversos tipos de fixação interna existentes ainda não há um consenso quanto ao método de imobilização das fraturas do ângulo mandibular. Além disso, são poucos os estudos sobre a utilização de placas grade ultimamente lançadas no mercado. O presente estudo visou avaliar comparativamente a resistência entre três tipos de fixação interna em réplicas de hemimandíbulas de poliuretano seccionadas na região de ângulo mandibular, simulando uma fratura linear. As formas de fixação incluíram a utilização de placas em forma de grade com e sem barra intermediária e o método descrito por Champy (1978). O objetivo foi definir por meio de análise mecânica a técnica que permitiu maior resistência na fixação deste tipo de fratura. Os testes de carregamento linear vertical foram realizados em amostras de cada grupo estudado (n = 10) utilizando uma unidade de testes mecânicos para registro da carga atingida, nos momentos que o deslocamento vertical alcançou 3 mm e 5 mm. Médias e desvio padrão foram avaliados aplicando-se a Análise de Variância e o teste de Duncan em nível de significância de 5%. Concluiu-se que a técnica de fixação interna para as fraturas de ângulo mandibular descrita por Champy (1976) foi a mais resistente e, que a inclusão de barra vertical intermediária nas placas grade não ofereceu aumento da resistência quando comparadas às placas grade sem barra / Abstract: Although there are several methods of stable fixation, there is no consensus about the treatment of mandibular angle fractures, Also, there are few studies about grid plates recently commercially available. This study compares the resistance of three fixation methods in polyurethane hemimandible replicas. Those were osteotomized at the angle region to simulate a linear fracture. Fixation methods were four-hole 2.0mm grid plates with and without a vertical intermediate bar and 2.0mm four-hole straight plate. The objective was to determine, through mechanical analysis, the fixation method that results in greater resistance to displacement. The hemimandibles were submitted to vertical linear loading in a mechanical test unit for registration of load after displacement of 3 and 5mm. Means and standard deviation were determined. Variance analysis and Ducan's test were applied considering a significance level of 5%. Results showed that the 2.0 four-hole plates, positioned according to the Champy technique, provide greater stability than the grid plates. When a vertical intermediate bar was added to the grid plates, resistance of the system was not increased / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
|
25 |
Análise mecânica e fotoelástica de sistemas de fixação interna estável utilizados para o tratamento de fraturas subcondilares da mandíbula / Mechanical and photoelastic analysis of internal fixation systems used for treatment of subcondylar mandibular fracturesAssis, Adriano Freitas de, 1977- 02 March 2012 (has links)
Orientador: Márcio de Moraes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T14:44:31Z (GMT). No. of bitstreams: 1
Assis_AdrianoFreitasde_D.pdf: 2569542 bytes, checksum: c5fe7cff19045423ecf179969933848b (MD5)
Previous issue date: 2012 / Resumo: As fraturas do côndilo mandibular apresentam-se como as injúrias mais comuns ao complexo maxilo-mandibular, contudo ainda existe controvérsia quanto ao seu tratamento. O objetivo neste estudo foi avaliar comparativamente, in vitro, por meio de testes mecânicos e fotoelásticos a fixação de fraturas condilares com diferentes sistemas. Para os testes mecânicos foram utilizadas 60 hemimandíbulas de poliuretano, que foram divididas em 12 grupos com 5 hemimandíbulas cada, sendo dois grupos controle com hemimandíbulas íntegras e mais dois grupos de cada tipo de fixação: duas placas retas do sistema 2,0mm, uma placa trapezoidal do sistema 2,0mm, uma placa trapezoidal com extensão do sistema 2,0mm, uma placa trapezoidal do sistema 1,5mm e uma placa trapezoidal com extensão do sistema 1,5mm. Foram realizados testes de carregamento linear no sentido ântero-posterior e médio-lateral. As médias foram comparados pelo teste de Tukey. As diferenças foram consideradas estatisticamente significantes para p ? 0,05. Para os testes fotoelásticos, foi utilizada uma amostra de 10 hemimandíbulas de resina fotoelástica, sendo duas para cada grupo, na mesma distribuição dos testes mecânicos, submetidas ao carregamento linear nos mesmos sentidos para análise do comportamento e distribuição das tensões. Os resultados indicaram que a fixação com duas placas apresenta maior resistência no sentido ântero-posterior e a fixação com uma placa trapezoidal com extensão apresenta maior resistência no sentido médio-lateral. A análise fotoelástica demonstrou que as tensões são melhores distribuídas nas fixações com placas trapezoidais. De acordo com os resultados foi possível concluir que a extensão posterior das placas trapezoidais aumentou a resistência do sistema de fixação e que a utilização de placa trapezoidal com ou sem extensão posterior foi favorável à distribuição de tensão de maneira mais uniforme / Abstract: Fractures of the mandibular condyle are presented as the most common injuries to the maxillo-mandibular complex, however there is still great controversy regarding treatment. The aim of this study was to assess comparatively, in vitro, by mechanical and photoelastic testing, fixation for condylar fractures with different systems. For the mechanical tests 60 polyurethane mandible models were used. They were divided into 12 groups of 5 mandibles, two control groups with intact mandibles and two groups of each type of fixation: two 2.0mm straight plates, a 2.0mm trapezoidal plate, a 2.0mm trapezoidal plate with extension, a 1.5mm trapezoidal plate and a 1.5mm trapezoidal plate with extension. Linear loading tests were carried out in anterior-posterior and medial-lateral directions. Mean and standard deviations were compared by Tukey test. Differences were considered statistically significant at p ? 0.05. For the photoelastic tests, 10 photoelastic mandibles were used, 2 for each group, in the same distribution as the mechanical tests, submitted to linear loading in the same directions to analyze the behavior and distribution of tensile strain lines. The results indicated that the fixation with two plates presented a higher resistance in the anteroposterior direction and fixation with a plate with trapezoidal extension is more resistant towards mediolateral. The photoelastic analysis showed that the strain lines were best distributed when trapezoidal plates were used. According to the results we concluded that the posterior extension of the trapezoidal plates increased the strength of the fixation system, and the use of trapezoidal plate with or without posterior extension was favorable to a more balanced stress distribution / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
|
26 |
Resistência de quatro técnicas de fixação utilizadas no tratamento das fraturas subcondilares = estudo in vitro em mandíbulas de poliuretano / Resistance of four fixation techniques used in the treatment of subcondyles fractures : study in vitro in mandibles of polyurethaneCavalieri-Pereira, Lucas, 1982- 18 August 2018 (has links)
Orientador: Alexandre Elias Trivellato / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T13:54:21Z (GMT). No. of bitstreams: 1
Cavalieri-Pereira_Lucas_M.pdf: 2145596 bytes, checksum: 3e8bd390800cac6c62907f984daa8941 (MD5)
Previous issue date: 2011 / Resumo: A fratura do côndilo mandibular usualmente requer tratamento cirúrgico com emprego de fixação interna estável. O objetivo neste estudo foi avaliar comparativamente a resistência de quatro técnicas de fixação utilizadas no tratamento de fraturas subcondilares. Foram empregadas 84 mandíbulas sintéticas, 147 placas retas e 546 parafusos. As mandíbulas foram submetidas a um seccionamento simulando uma fratura subcondilar esquerda e fixadas com quatro técnicas utilizando-se das placas de 2,0 e 1,5 mm, que deram origem a doze grupos experimentais, cada um com 7 mandíbulas. Chamou-se de grupos G1, G5 e G9, aqueles fixados com uma placa reta de 4 furos do sistema 2,0 mm. Os grupos G2, G6 e G10, foram fixados com uma placa de 4 furos dos sistema 2,0 mm e uma placa de 3 furos do sistema 1,5 mm. Grupos G3, G7 e G11, aqueles fixados com duas placas 2,0 mm, sendo a anterior de 3 furos; Grupos G4, G8 e G12, aqueles fixados com duas placas 2,0 mm de 4 furos. Cada sistema foi submetido ao teste de resistência com aplicação de carga no sentido súpero-inferior em máquina de ensaio EMIC, modelo DL2000. Em G1, G2, G3 e G4 a aplicação de carga foi no primeiro molar do lado da fratura simulada (MF). Em G5, G6, G7 e G8, no primeiro molar contralateral à fratura simulada (MC). Em G9, G10, G11 e G12, entre os incisivos centrais (I). Foram mensurados valores de carga para os deslocamentos de 1 mm, 2 mm e 5 mm. Os resultados obtidos no teste de resistência foram comparados utilizando análise de variância (ANOVA), seguido do teste de Tukey com nível de significância de 5%. Verificou-se valores de carga menores no grupo tratado com uma placa de 4 furos do sistema 2,0 mm, nos deslocamentos de 1 e 2 mm, com aplicação de carga em MF. Pode-se concluir que a utilização do sistema de fixação com duas placas proporciona maior resistência / Abstract: Fractures of mandibular condyles usually require surgical treatment with steady employment internal fixation. The aim in this study was to evaluate the resistance of four fixation technique used in the treatment of subcondylar fractures. Were employed 84 synthetic jaws, 147 straight plates and 546 screws. The jaws underwent a sectioning simulating a left subcondylar fracture and fixed with four techniques using 2.0 mm and 1.5 mm plates, which gave rise to twelve experimental groups, each with 7 mandibles. Drew G1, G5 and G9, those set with single straight plate 4-holes. Groups G2, G6 and G10, were fixed with one 2.0 mm system plate 4-holes and one 1.5 mm system plate 3-hole. Groups G3, G7 and G11, were fixed with two plates 2.0 mm, which more anterior had 3-hole. Groups G4, G8 and G12, those fixed with two plates 2.0 mm with 4-hole. Each system was subjected to the test of resistance with load application superior-inferior on testing machine EMIC model DL2000. In G1, G2, G3 and G4 the implementation of load was the first molar side fracture simulated (MF). In G5, G6, G7 and G8 were in the first molar contralateral to the simulated fracture (MC). In G9, G10, G11 and G12 was between the central incisors (I). Load values were measured for displacement from 1 mm, 2 mm and 5 mm. Results obtained in the test of resistance were compared using analysis of variance (ANOVA), followed by Tukey test with a significance level off 5%. There was minor loads value in the group treated with a plate of 4-hole system 2.0 mm, in displacements of 1 and 2 mm, with application in MF. Can conclude that the use of the fixation system with two plates provide greater resistance / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
|
27 |
Estudo biomecânico comparativo de sistemas de fixação de 2,0-mm locking e convencionais em fraturas de ângulo em mandíbulas de cordeiro sob esforços em três eixos no espaço / Comparative biomechanical study of locking and conventional 2,0-mm fixation systems on angle fractures in sheep\'s mandibles under stresses on three axes in spaceSaavedra, Milton de Siqueira Ferreira Anzaloni 23 February 2017 (has links)
O objetivo deste trabalho foi avaliar comparativamente a rigidez vertical, horizontal e de resistência à ruptura, com liberdade de movimentos em três eixos no espaço, de mandíbulas fixadas com sistemas 2,0-mm locking e convencionais com uma ou duas placas, em fraturas unilaterais no ângulo mandibular. Vinte mandíbulas de cordeiro, submetidas a osteotomia reproduzindo fraturas, foram divididas em três grupos: F1PC - placa convencional em linha oblíqua; F2PC - duas placas convencionais de modo monoplanar; FL - placa de sistema locking 2,0mm em linha oblíqua. Foi utilizada máquina de ensaio universal, onde foi acoplado suporte metálico com rodas para as mandíbulas. O sistema foi analisado em três diferentes momentos: pré-osteotomia com mandíbulas hígidas e pós-osteotomia/fixação e resistência à ruptura. Os valores de rigidez foram submetidos a análise de variância (p<0,005). Os valores de rigidez vertical (p< 0,0001), horizontal (p= 0,0005) e resistência a ruptura (p= 0,0001) entre pré e pósosteotomia/ fixação apresentaram uma diminuição significante. Na comparação entre os grupos, houve diferença significante para a rigidez vertical (p= 0,009) e o grupo F2PC apresentou maior rigidez. Na comparação entre os grupos, não houve diferença significante para a rigidez horizontal e para resistência a ruptura. Foi concluído que para rigidez vertical, horizontal e resistência a ruptura os valores de pós-osteotomia/fixação foram significantemente menores, o sistema de fixação com duas placas convencionais mostrou maior resistência quanto à rigidez vertical que os demais sistemas e não houve diferença estatisticamente significante na comparação entre os grupos quanto a rigidez horizontal e resistência a ruptura. / The objective of this work was to evaluate the vertical, horizontal and tensile rigidity with freedom of movement in three axes in space, of mandibles fixed with 2.0-mm locking and conventional systems with one or two plates, in unilateral fractures in the Angle of the mandible. Twenty mandibles of lamb, submitted to osteotomy and reproducing fractures, were divided into three groups: F1PC - conventional oblique line; F2PC - two conventional single-mode boards; FL - 2.0mm locking system plate in oblique line. A universal test machine was used, where metal support was coupled with wheels for the jaws. The system was analyzed in three different moments: pre-osteotomy with healthy mandibles and post-osteotomy / fixation and resistance to rupture. The stiffness values were submitted to analysis of variance (p <0.005). The values of vertical rigidity (p <0.0001), horizontal (p = 0.0005) and resistance to rupture (p = 0.0001) between pre and post osteotomy / fixation showed a significant decrease. In the comparison between the groups, there was a significant difference for vertical stiffness (p = 0.009) and the F2PC group presented greater stiffness. In the comparison between the groups, there was no significant difference for horizontal rigidity and for resistance to rupture. It was concluded that for post-osteotomy / fixation values were significantly lower for vertical, horizontal and tensile rigidity, the fixation system with two conventional plates showed greater resistance to vertical rigidity than the other systems and there was no statistically significant difference in comparison between the groups for horizontal rigidity and resistance to rupture.
|
28 |
Avaliação da vida em fadiga de placas ósseas metálicas sob condições pre-operatóriasZimmer, Cinthia Gabriely January 2014 (has links)
Placa óssea é o nome designado para os implantes sintéticos utilizados como suporte – a fim de auxiliar na consolidação óssea − quando por algum motivo ocorrer fratura do sistema ósseo do corpo humano. Esta tese investiga o comportamento em fadiga de placas ósseas, do tipo DCP (Dynamic Compression Plate), utilizadas no tratamento de fraturas do fêmur, fabricadas em aço inoxidável e submetidas a condições pré-operatórias. A deformação pré-operatória é uma prática comum realizada antes da operação cirúrgica, a qual consiste no encurvamento do componente, com o objetivo de ajustar a placa à anatomia do osso, aumentando a compressão nos ossos fraturados e facilitando a consolidação óssea. O encurvamento da placa gera deformação plástica permanente no metal, sendo previsto na norma de placas ósseas da série ABNT NBR 15676 (equivalente à ASTM F 382). Contudo, na mesma série de normas, é recomendado que o ensaio de fadiga em flexão seja conduzido sem a deformação da placa, o que não condiz com a realidade de utilização do componente. Desta forma, uma investigação aprofundada sobre as tensões residuais impostas pelo encurvamento da placa, e suas consequências na vida em fadiga foram analisadas, com o intuito de verificar a influência deste procedimento na resistência do componente. Para isto, 30 placas foram avaliadas quanto aos seguintes requisitos: acabamento superficial (lupa), tensões residuais (difratômetro de raio X), flexão estático e fadiga (máquina de ensaios mecânicos servo-hidráulica), superfície de fratura (microscópio eletrônico de varredura) e aspecto microestrutural (microscópio ótico). Os resultados indicam que o dobramento controlado pode contribuir para resistência da placa, porém se o dobramento for realizado de forma descontrolada, a resistência à fadiga é reduzida, expondo o paciente a um risco de fratura do componente metálico dentro do corpo. / Bone plate is the name designated to the synthetic implants used to give support to a fractured bone of the human skeletal system. This thesis investigates the fatigue behavior of DCP (Dynamic Compression Plate) plate bone, which is used for treatment of femoral fractures, treatment of femoral fractures manufactured in stainless steel and subjected to preoperative conditions. Preoperative deformation, or contouring, is a common practice performed before surgical operation, which consists to bend the component, in order to adjust it to the bone anatomy, increasing the compression on the fractured bones and facilitating bone healing. This practice is predicted in the bone plates standard (ABNT NBR 15676/ASTM F382). However, the test method recommends that the test should be conducted without contouring, but this is not consistent with the reality of the component use. Thus, a thorough investigation of residual stresses imposed by the plate bending and their consequences on fatigue limit were analyzed, in order to check the influence of this procedure on the strength of the component. Therefore, 30 plates were evaluated against the following requirements: surface finish (stereoscopic microscope), residual stress (X-ray diffractometer), static and dynamic bend testing (Servo Hydraulic Mechanical Testing Machines), fracture surface analysis (scanning electron microscope) and microstructural aspects (optical microscope). The results indicate that controlled bending contributes to plate strength, but if uncontrolled bending is carried out, the fatigue strength is reduced, exposing the patient to a risk of breaking the component inside the body.
|
29 |
Estudo biomecânico comparativo de sistemas de fixação de 2,0-mm locking e convencionais em fraturas de ângulo em mandíbulas de cordeiro sob esforços em três eixos no espaço / Comparative biomechanical study of locking and conventional 2,0-mm fixation systems on angle fractures in sheep\'s mandibles under stresses on three axes in spaceMilton de Siqueira Ferreira Anzaloni Saavedra 23 February 2017 (has links)
O objetivo deste trabalho foi avaliar comparativamente a rigidez vertical, horizontal e de resistência à ruptura, com liberdade de movimentos em três eixos no espaço, de mandíbulas fixadas com sistemas 2,0-mm locking e convencionais com uma ou duas placas, em fraturas unilaterais no ângulo mandibular. Vinte mandíbulas de cordeiro, submetidas a osteotomia reproduzindo fraturas, foram divididas em três grupos: F1PC - placa convencional em linha oblíqua; F2PC - duas placas convencionais de modo monoplanar; FL - placa de sistema locking 2,0mm em linha oblíqua. Foi utilizada máquina de ensaio universal, onde foi acoplado suporte metálico com rodas para as mandíbulas. O sistema foi analisado em três diferentes momentos: pré-osteotomia com mandíbulas hígidas e pós-osteotomia/fixação e resistência à ruptura. Os valores de rigidez foram submetidos a análise de variância (p<0,005). Os valores de rigidez vertical (p< 0,0001), horizontal (p= 0,0005) e resistência a ruptura (p= 0,0001) entre pré e pósosteotomia/ fixação apresentaram uma diminuição significante. Na comparação entre os grupos, houve diferença significante para a rigidez vertical (p= 0,009) e o grupo F2PC apresentou maior rigidez. Na comparação entre os grupos, não houve diferença significante para a rigidez horizontal e para resistência a ruptura. Foi concluído que para rigidez vertical, horizontal e resistência a ruptura os valores de pós-osteotomia/fixação foram significantemente menores, o sistema de fixação com duas placas convencionais mostrou maior resistência quanto à rigidez vertical que os demais sistemas e não houve diferença estatisticamente significante na comparação entre os grupos quanto a rigidez horizontal e resistência a ruptura. / The objective of this work was to evaluate the vertical, horizontal and tensile rigidity with freedom of movement in three axes in space, of mandibles fixed with 2.0-mm locking and conventional systems with one or two plates, in unilateral fractures in the Angle of the mandible. Twenty mandibles of lamb, submitted to osteotomy and reproducing fractures, were divided into three groups: F1PC - conventional oblique line; F2PC - two conventional single-mode boards; FL - 2.0mm locking system plate in oblique line. A universal test machine was used, where metal support was coupled with wheels for the jaws. The system was analyzed in three different moments: pre-osteotomy with healthy mandibles and post-osteotomy / fixation and resistance to rupture. The stiffness values were submitted to analysis of variance (p <0.005). The values of vertical rigidity (p <0.0001), horizontal (p = 0.0005) and resistance to rupture (p = 0.0001) between pre and post osteotomy / fixation showed a significant decrease. In the comparison between the groups, there was a significant difference for vertical stiffness (p = 0.009) and the F2PC group presented greater stiffness. In the comparison between the groups, there was no significant difference for horizontal rigidity and for resistance to rupture. It was concluded that for post-osteotomy / fixation values were significantly lower for vertical, horizontal and tensile rigidity, the fixation system with two conventional plates showed greater resistance to vertical rigidity than the other systems and there was no statistically significant difference in comparison between the groups for horizontal rigidity and resistance to rupture.
|
30 |
Avaliação da vida em fadiga de placas ósseas metálicas sob condições pre-operatóriasZimmer, Cinthia Gabriely January 2014 (has links)
Placa óssea é o nome designado para os implantes sintéticos utilizados como suporte – a fim de auxiliar na consolidação óssea − quando por algum motivo ocorrer fratura do sistema ósseo do corpo humano. Esta tese investiga o comportamento em fadiga de placas ósseas, do tipo DCP (Dynamic Compression Plate), utilizadas no tratamento de fraturas do fêmur, fabricadas em aço inoxidável e submetidas a condições pré-operatórias. A deformação pré-operatória é uma prática comum realizada antes da operação cirúrgica, a qual consiste no encurvamento do componente, com o objetivo de ajustar a placa à anatomia do osso, aumentando a compressão nos ossos fraturados e facilitando a consolidação óssea. O encurvamento da placa gera deformação plástica permanente no metal, sendo previsto na norma de placas ósseas da série ABNT NBR 15676 (equivalente à ASTM F 382). Contudo, na mesma série de normas, é recomendado que o ensaio de fadiga em flexão seja conduzido sem a deformação da placa, o que não condiz com a realidade de utilização do componente. Desta forma, uma investigação aprofundada sobre as tensões residuais impostas pelo encurvamento da placa, e suas consequências na vida em fadiga foram analisadas, com o intuito de verificar a influência deste procedimento na resistência do componente. Para isto, 30 placas foram avaliadas quanto aos seguintes requisitos: acabamento superficial (lupa), tensões residuais (difratômetro de raio X), flexão estático e fadiga (máquina de ensaios mecânicos servo-hidráulica), superfície de fratura (microscópio eletrônico de varredura) e aspecto microestrutural (microscópio ótico). Os resultados indicam que o dobramento controlado pode contribuir para resistência da placa, porém se o dobramento for realizado de forma descontrolada, a resistência à fadiga é reduzida, expondo o paciente a um risco de fratura do componente metálico dentro do corpo. / Bone plate is the name designated to the synthetic implants used to give support to a fractured bone of the human skeletal system. This thesis investigates the fatigue behavior of DCP (Dynamic Compression Plate) plate bone, which is used for treatment of femoral fractures, treatment of femoral fractures manufactured in stainless steel and subjected to preoperative conditions. Preoperative deformation, or contouring, is a common practice performed before surgical operation, which consists to bend the component, in order to adjust it to the bone anatomy, increasing the compression on the fractured bones and facilitating bone healing. This practice is predicted in the bone plates standard (ABNT NBR 15676/ASTM F382). However, the test method recommends that the test should be conducted without contouring, but this is not consistent with the reality of the component use. Thus, a thorough investigation of residual stresses imposed by the plate bending and their consequences on fatigue limit were analyzed, in order to check the influence of this procedure on the strength of the component. Therefore, 30 plates were evaluated against the following requirements: surface finish (stereoscopic microscope), residual stress (X-ray diffractometer), static and dynamic bend testing (Servo Hydraulic Mechanical Testing Machines), fracture surface analysis (scanning electron microscope) and microstructural aspects (optical microscope). The results indicate that controlled bending contributes to plate strength, but if uncontrolled bending is carried out, the fatigue strength is reduced, exposing the patient to a risk of breaking the component inside the body.
|
Page generated in 0.0557 seconds