• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Stratégies de médecine "régénérative" pour la réparation de la peau dans un modèle murin de brûlure profonde / Regenerative medicine strategies in a mouse model of burns wound healing

Perez, Guillaume 17 June 2015 (has links)
La cicatrisation et la régénération sont les deux processus de réparation observés dans le règne animal. Toutefois, les mammifères ne sont susceptibles de réparer une blessure que par la constitution d'une cicatrice qui ne restitue point la structure et les propriétés du tissu initial. Dans un contexte de brûlure profonde, la cicatrisation, le plus souvent excessive, peut retentir négativement sur la vie de l'individu. A cette aune, nous nous somme proposé de mettre au point des thérapies innovantes, dans un modèle murin de brûlure, dans le but de réduire ou de réorienter une réaction cicatricielle anormale. La première stratégie était une thérapie cellulaire basée sur l'utilisation des cellules stromales mésenchymateuses du tissu adipeux. Bien que les études effectuées aient révélé des aptitudes immunomodulatrices encourageantes, l'utilisation de ces cellules n'a pas apporté de résultats probants pour prétendre combattre la cicatrisation excessive de notre modèle. La seconde stratégie s'appuyait sur les enseignements tirés de la première approche et de la régénération animale. Les brûlures ont été traitées par des jets de plasma froid à pression atmosphérique. La prise en charge des lésions par ce nouvel outil entraina singulièrement une diminution de la zone cicatricielle. Les expériences montrèrent que le plasma circonscrivit la cicatrisation par l'atténuation de l'inflammation et du dépôt matriciel subséquent ; il en résulta une fibrose dermique quasi-inexistante, l'émergence de follicules pileux en régénération et une récupération de l'hypoderme. En conclusion, le plasma froid améliore significativement la cicatrisation des brûlures profondes. / Scarring and regeneration are both repair processes observed in the animal kingdom, even though mammals always heal by a scar tissue formation that never restitute the initial tissue structure and properties. Burns healing can become abnormal and may subsequently affect the person's daily life. Considering pathological healings, we developed innovative regenerative medicine strategies to reduce or redirect the wound healing process towards a better issue in a mouse model of skin burn. First, we performed a cell therapy based on the administration of adipose mesenchymal stromal cells. Although the experiments showed promising immunomodulatory abilities, such cells failed to provide convincing results in our model of excessive burn healing. The second intent was designed after findings from the first approach and knowledge from regenerative models. Deep skin burns were treated by cold atmospheric plasma. We found that plasma-treated lesions were repaired by a considerably diminished scar. Experiments showed that the plasma treatment resulted in almost inexistent fibrosis through a reduction of inflammation and matrix deposition, emergence of regeneration follicles regeneration and a better restitution of hypodermis. In conclusion, cold atmospheric plasma significantly improves healing when applied on skin burns.
2

Utilisation d'une décharge à barrière diélectrique pour développer une matrice polymère plasma dégradable pour des applications vasculaires / Using a dielectric barrier discharge to develop a degradable plasma polymer matrix for vascular applicationsg

Laurent, Morgane 03 November 2017 (has links)
Chaque année, environ 1,5 million de patients requièrent un remplacement vasculaire en réponse à une athérosclérose avancée, causant le rétrécissement interne des vaisseaux sanguins. Malheureusement, encore aujourd'hui les matériaux synthétiques utilisés pour remplacer les artères de petits diamètres (inférieurs à 6 mm) restent associés à un haut taux d'échecs, démontrant ainsi un manque de biocompatibilité certain. L'une des principales complications observées est l'hyperplasie néointimale artérielle caractérisée par l'obstruction du vaisseau sanguin due à la prolifération tridimensionnelle de cellules sur la paroi interne de la prothèse. Différentes stratégies visant à limiter cette réaction naturelle sont aujourd'hui envisagées, notamment l'utilisation d'un système à libération contrôlée de médicament intégré localement aux prothèses vasculaires. En parallèle, l'essor des technologies plasma a permis de montrer qu'il était possible de revêtir la surface de matériel biomédical pour améliorer son interaction avec un environnement biologique. La stratégie consiste à utiliser l'énergie et la réactivité d'un plasma pour polymériser un précurseur gazeux. En sélectionnant la structure moléculaire du précurseur et les conditions expérimentales du plasma appropriées, il est possible de déposer un polymère plasma à la surface du matériel sélectionné pour lui conférer des propriétés sur mesure. C'est dans ce contexte que cette thèse a consisté à synthétiser, à l'aide d'un plasma, une matrice polymère plasma biodégradable pour revêtir la paroi interne d'une prothèse vasculaire, dans le but d'y incorporer un médicament choisi de façon à limiter l'hyperplasie néointimale. Ce projet a permis d'une part de réaliser une preuve de concept en déposant un revêtement polymère plasma dégradable par décharge à barrière diélectrique en configuration planaire. En utilisant le lactate d'éthyle en tant que précurseur et après de nombreuses analyses, des conditions de dépôt optimales ont pu être élues pour leur potentiel dans le cadre d'applications vasculaires. D'autre part, grâce à une caractérisation approfondie de la décharge, une corrélation étroite entre la physico-chimie du plasma et les dépôts dégradables obtenus a pu être établie. Afin d'élargir les possibilités de vitesse de dégradation, l'influence d'une alimentation impulsionnelle sur la décharge et sur le dépôt a de plus été étudiée. Si la manière d'apporter l'énergie a eu une forte influence sur la décharge, aucune influence majeure n'a été notée sur la chimie et la morphologie des dépôts faits à partir de lactate d'éthyle. Enfin, la construction d'un réacteur plasma tubulaire permettant de déposer la matrice développée à l'intérieur de prothèses artérielles a permis de s'étendre aux conditions réelles de dépôt. Dans l'ensemble, ce projet de recherche a mis en évidence le potentiel des procédés plasma pour le développement de matrices polymères plasma dégradables, notamment dans le cadre de systèmes à libération contrôlée et locale de médicaments pour des applications en chirurgie vasculaire. D'un point de vue de la physique des plasmas, ce travail a de plus souligné l'importance de l'étude de la décharge dans de véritables conditions de dépôt de couches minces. / Every year, about 1.5 million patients need a vascular replacement due to advanced arteriosclerosis, which causes the internal narrowing of blood vessels. Unfortunately, even today the synthetic materials used to replace small diameter arteries (below 6 mm) remain associated with low patency rate, which demonstrates an evident lack of biocompatibility. One of the main observed complications is arterial neointimal hyperplasia, which is characterized by the blood vessel obstruction due to the tridimensional proliferation of cells on the graft internal wall. Different strategies aiming at limiting this body reaction are currently considered, in particular the use of a drug delivery system locally integrated to the vascular grafts. Concurrently, the rise of plasma technologies enabled to demonstrate the possibility to coat the surface of biomedical devices to improve their interaction with a biological environment. The strategy consists in using the plasma energy and reactivity to polymerize a gaseous precursor. By selecting the appropriate precursor molecular structure and plasma experimental conditions, one can build up a plasma polymer with tailored properties. It is in this context that this thesis consisted in synthesizing, using plasma, a biodegradable polymeric plasma polymer matrix to coat the internal wall of a vascular graft, with the goal to incorporate a drug chosen to limit neointimal hyperplasia. On one hand, this project acted as proof of concept by developing a degradable plasma polymer coating using a planar dielectric barrier discharge. After extensive studies using ethyl lactate as precursor, optimal chemical vapor deposition conditions were elected for their potential in terms of vascular applications. On the other hand, thanks to an extended discharge characterization, a strong correlation was established between the plasma physico-chemistry and the properties of the degradable coatings synthesized. In addition, to broaden possibilities in terms of degradation rate, the influence of a squared pulse power supply on the discharge and the coating was studied. If changing the way to bring the energy had a strong influence on the discharge, no major influence was noticed on the ethyl lactate-based coatings' chemistry and morphology. Finally, a tubular plasma reactor was build up to empower the internal wall of vascular prosthesis to be coated, which enabled to extend this project to the deposition conditions of its final application. Overall, this research project highlighted the potential of plasma processes for the development of degradable plasma polymer matrices, particularly for local drug delivery systems for vascular applications. On a physics perspective, this work emphasized the importance of studying the discharge under actual thin layer deposition conditions.
3

Étude des mécanismes d'adhésion entre une gomme caoutchouc et un fil métallique revêtu d'une couche mince déposée par plasma / Study of adhesion mechanisms between rubber and zinc-plated steel wires coated with plasma polymerized organo-chlorinated thin films

Vandenabeele, Cédric 15 April 2014 (has links)
L'objectif de cette thèse est de développer un procédé plasma qui puisse se substituer au procédé de dépôt électrolytique de laiton, actuellement appliqué sur les fils d'acier utilisés comme matériaux de renforcement dans un pneu, pour les faire adhérer au caoutchouc. La stratégie employée consiste à déposer une couche mince organochlorée en continu sur un fil d'acier zingué, qui traverse une décharge à barrière diélectrique tubulaire, fonctionnant à la pression atmosphérique, dans une configuration fil-cylindre. Dans un premier temps, les travaux se concentrent sur la caractérisation de la décharge et de la couche mince déposée à la fois en mode statique (substrat immobile dans le réacteur) et dynamique (substrat en défilement). Des relations sont établies entre les paramètres plasma (puissance dissipée dans la décharge, fréquence de la source haute tension, flux de précurseur), les propriétés de la décharge et les caractéristiques du revêtement plasma. Des études morphologique, cinétique et chimique de la couche mince sont réalisées. Dans un second temps, la préparation de la surface du substrat et le dépôt plasma sont optimisés pour permettre d'obtenir les meilleurs niveaux d'adhésion entre l'acier zingué et le caoutchouc. À l'issue de ce travail d'optimisation, des analyses sont réalisées pour identifier la nature de la nouvelle interphase d'adhésion. Cette étude se conclut alors par une discussion sur l'origine possible des liens qui s'opèrent dans ce nouveau système / The primary objective of this thesis project is to develop a plasma process able to replace the electrolytic brass plating process, which is currently performed on steel wires used as reinforcing materials in tires to make them bond with rubber. The chosen strategy consists in depositing organo-chlorinated thin films in a continuous way on zinc-plated steel wires going across a tubular atmospheric pressure dielectric barrier discharge in a wire-cylinder configuration. In a first time, works focus on characterization of both the discharge and the plasma layer, deposited in the static (substrate stationary in the reactor) and dynamic (moving substrate) modes. Relationships are established between the plasma parameters (power dissipated in the discharge, high voltage source frequency, precursor flow rate), the discharge properties and the thin film characteristics. Morphological, kinetic and chemical studies of the plasma layer are carried out. In a second time, the substrate surface preparation and the coating are optimized to enhance the adhesion between zinc-plated steel wires and rubber. Analyses are performed to identify the new adhesion interface nature. At the end of this study, hypotheses concerning the adhesion origin in this system are formulated
4

Etude de la production des espèces réactives de l’oxygène et de l’azote par décharge Plasma Gun à pression atmosphérique pour des applications biomédicales / Study of oxygen and nitrogen reactive species production in atmospheric pressure Plasma Gun discharge for biomedical applications

Darny, Thibault 27 June 2016 (has links)
En l’espace d’une dizaine d’années, les jets de plasma froid à pression atmosphérique ont su s’imposer comme un outil pertinent pour les applications biomédicales. La simplicité de conception et d’utilisation de ces dispositifs, combinée à leurs facultés de produire des espèces réactives (NO, OH, O …), ont significativement contribué au développement rapide du domaine. Beaucoup d’efforts ont été entrepris dans le développement de diagnostics quantitatifs, pour mesurer la production des espèces réactives dans la plume plasma d’un jet donné. Toutefois, la diversité des géométries de décharge, des sources d’alimentations électriques ou des conditions d’utilisation, rendent les comparaisons d’un jet à l’autre, difficiles. Cette thèse a porté sur l’étude du jet de plasma froid à pression atmosphérique développé au GREMI, le Plasma Gun (hélium, impulsion de tension microseconde). Nous avons étudié les mécanismes de décharge susceptibles de considérablement affecter la production d’espèces réactives, dans des conditions approchantes d’applications biomédicales. La thèse s’articule en trois chapitres principaux : l’étude de la modification de l’écoulement de l’hélium par plasma (par strioscopie) ; l’étude de la propagation du plasma dans le capillaire diélectrique (étude expérimentale et numérique de la dynamique de propagation rapide du plasma et de l’évolution du champ électrique en mélange hélium-azote) ; l’étude de l’interaction du plasma avec une cible conductrice (mesures dans le capillaire et dans la plume de l’évolution spatiale et temporelle de la concentration des métastables de l’hélium, corrélées à des mesures du champ électrique). Ce dernier point est en particulier représentatif de tout jet plasma en condition traitement biomédical in vivo et tend à faire une distinction fondamentale avec les mécanismes de décharge du jet plasma dit « libre », sans obstacle entravant la plume plasma. / Over the past ten years, the cold atmospheric pressure plasma jets (CAPPJ) became useful devices for biomedical applications. Their relatively simple design and use, combine with their ability to produce reactive species (NO, OH, O, …), led to a rapid research growth in this field. A lot of studies have been devoted to quantitative diagnostics development for the reactive species production measurements in the plasma plume. However, it is difficult to compare one jet with another because of the huge variety of discharge geometries, electric power supplies or operating conditions. This thesis deals with the study of the CAPPJ developed in GREMI, the Plasma Gun (helium feeded, microsecond voltage pulse). We have studied discharge mechanisms which strongly impact the reactive species production in near target biomedical application conditions. This study is divided in three parts : the study of helium flow modifications induced by the plasma (strioscopy visualization); the study of plasma propagation inside dielectric capillary (experimental and numerical study of fast plasma propagation dynamic and electric field evolution for helium-nitrogen mixtures); the study of conductive target-plasma interaction (space and time resolved measurements inside the capillary and the plasma plume of helium metastable production, correlated with electric field evolution). The conductive target contact concerns any in vivo biomedical treatments. CAPPJ in front of such a conductive target leads to fundamentally different discharge mechanisms compare to the free jet case.
5

Transition des basses fréquences aux hautes fréquences d’une décharge à barrière diélectrique en hélium à la pression atmosphérique

Boisvert, Jean-Sébastien 06 1900 (has links)
No description available.

Page generated in 0.1255 seconds