• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Amélioration des propriétés antibactériennes et anticoagulantes des prothèses vasculaires en polyester par immobilisation et libération contrôlée de principes actifs / Improvement of antibacterial and anticoagulant properties of polyester vascular prostheses by immobilization and controlled release of biologically active compounds

Jean Baptiste, Elixène 20 June 2012 (has links)
Les prothèses et les endoprothèses vasculaires, une fois implantées dans le corps humain, sont sujettes à un certain nombre de complications. Les infections, les thromboses précoces et les occlusions tardives sont les plus fréquentes, générant des conséquences cliniques très souvent délétères et parfois létales. Les difficultés de prise en charge de ces complications sont à l’origine des efforts déployés dans la recherche de solutions visant à améliorer les matériaux prothétiques. Aucune avancée clinique majeure n’a jusque-là été notée. Des études réalisées antérieurement dans notre laboratoire ont permis de développer des prothèses vasculaires en polyester dotées d’un revêtement de polymère d’hydroxypropyl-β-cyclodextrine capable d’adsorber puis de libérer de manière prolongée divers antibiotiques. Au cours des présents travaux nous avons déterminé les conditions optimales pour une libération effective de trois antibiotiques à partir de ces prothèses revêtues d’hydroxypropyl-β-cyclodextrine. Nous en avons testé l’efficacité dans des modèles in vitro et in vivo d’infections vasculaires. Nous avons eu recours à neuf souches pathogènes parmi les plus fréquemment rencontrées dans ce contexte en pathologie humaine. Nous avons parallèlement évalué in vivo l’innocuité, la tolérance tissulaire et la biocompatibilité de ces prothèses dans la perspective d’une application clinique. Le système développé s’est avéré efficace en libérant in situ sur une huitaine de jours les molécules antibactériennes sélectionnées. Les concentrations requises des solutions ainsi que le temps nécessaire d’imprégnation des prothèses étaient compatibles avec la pratique chirurgicale. Une activité bactéricide par réduction significative de l’adhésion, de la croissance et de la prolifération bactérienne a été observée comparativement aux témoins dans les différents modèles d’infections testés. Nos résultats démontrent aussi la possibilité d’utiliser ces molécules seules ou en association sans qu’il y ait d’antagonisme. Il deviendra ainsi possible de moduler et d’adapter le traitement antibiotique local, délivré in situ, en ciblant les divers pathogènes rencontrés dans le cadre d’infections mono ou polymicrobiennes. Les prothèses revêtues d’hydroxypropyl-β-cyclodextrine ont démontré in vivo une bonne intégration tissulaire et une excellente tolérance locale sans signe de toxicité systémique. [...] / Synthetic vascular prosthesis likewise vascular endoprosthesis are prone to several complications after implantation into the human body. Infections, thromboses and late occlusions are the most challenging and the most common, leading to serious clinical consequences that are sometimes lethal. Management of those complications is still fraught with tremendous difficulties justifying the economic burden and the continuous efforts in research development for improving vascular prosthetic materials. This research investment is, however, yet to yield any great clinical advance. Previous studies conducted in our research laboratory have led to the development of polyester vascular prostheses coated with a polymer of hydroxypropyl-β-cyclodextrin. This was achieved in order to increase the loading and eluting capacities of these vascular prostheses towards several antibiotics. In the current works, we sought to determine the optimal conditions for effective controlled release of three antibiotics from those prosthetic platforms. We have also evaluated their efficacy in both in vitro and in vivo models of vascular infections. This was carried-out against nine different bacteria strains that are among the most common in human vascular infections. Moreover, we have assessed in vivo their safety, their healing properties, their systemic toxicity and their biocompatibility in the prospect of clinical application.The above-mentioned drug delivery system has been proved to be effective in releasing in situ the selected antibacterial agents over a seven-day desorption period in human plasma. Optimal batch concentration and time for prosthetic immersion into the antibiotic solutions were well compatible with current surgical practice standards. A bactericidal activity evidenced by significant reduction of bacterial adhesion, growth and proliferation was revealed when compared to appropriate controls in the various tested vascular infection models. We have also studied antibacterial molecules alone or in combination. In this latter setting, no antagonistic effects were depicted. This provides a unique opportunity to customize local antibiotic treatment delivered in situ from vascular device fabrics and to adapt it to the evolving ecology of both monomicrobial and polymicrobial vascular prosthetic infection. The polyester vascular prostheses coated with a polymer of hydroxypropyl-β-cyclodextrin were proved in vivo safe and demonstrated excellent biocompatibility, healing properties and tissue integration without any signs of systemic toxicity. [...]
2

Optimisation de la structure textile des prothèses vasculaires pour un développement en monocouche des cellules endotheliales

François, Sébastien 07 December 2009 (has links) (PDF)
Les prothèses vasculaires textiles en polyéthylène téréphtalate (PET) présentent souvent des occlusions après implantation pour les petits diamètres (6-8mm) car la surface des prothèses est peu hémocompatible. Or, l'hémocompatibilité des prothèses serait largement améliorée si ces dernières se recouvraient d'une couche de cellules endothéliales qui tapissent naturellement les vaisseaux sanguins. Ce projet vise à mettre en évidence que les textiles bruts ne sont pas un support viable pour le développement de ces cellules endothéliales, puis propose de remplacer les matrices protéiniques par un recouvrement synthétique. Pour ce faire, de l'acide poly-L-lactique (PLA) solubilisé a été filé sous forme de nanofibres déposées sur la surface luminale de la prothèse. L'étirage par jet d'air a été caractérisé selon un modèle plan, puis adapté à la fon11e tubulaire des prothèses. Les nanofibres ont été évaluées sur le plan de la cytocompatibilité, de l'adhérence et de la prolifération avec un modèle de cellules endothéliales animales. Ce travail vise aussi à optimiser l'adhérence de ces fibres sur le PET par l'emploi d'une technique de modification de surface par plasma. Les résultats montrent qu'il est possible de produire des nanofibres de PLA et de contrôler leur diamètre, et de sceller la paroi de la prothèse textile. Enfin, les cellules endothéliales prolifèrent en monocouche sur des prothèses recouve1tes de nanofibres. Il est possible d'optimiser l'adhérence des nanofibres sur le PET avec un traitement par plasma. En conclusion nous avons proposé une alternative à l'enduction traditionnelle des prothèses permettant la prolifération en monocouche des cellules endothéliales.
3

Optimisation de la structure textile des prothèses vasculaires pour un développement en monocouche des cellules endotheliales / Vascular textile prostheses optimization for an endothelial cells monolayer devlopment

François, Sébastien 07 December 2009 (has links)
Les prothèses vasculaires textiles en polyéthylène téréphtalate (PET) présentent souvent des occlusions après implantation pour les petits diamètres (6-8mm) car la surface des prothèses est peu hémocompatible. Or, l'hémocompatibilité des prothèses serait largement améliorée si ces dernières se recouvraient d'une couche de cellules endothéliales qui tapissent naturellement les vaisseaux sanguins. Ce projet vise à mettre en évidence que les textiles bruts ne sont pas un support viable pour le développement de ces cellules endothéliales, puis propose de remplacer les matrices protéiniques par un recouvrement synthétique. Pour ce faire, de l'acide poly-L-lactique (PLA) solubilisé a été filé sous forme de nanofibres déposées sur la surface luminale de la prothèse. L'étirage par jet d'air a été caractérisé selon un modèle plan, puis adapté à la fon11e tubulaire des prothèses. Les nanofibres ont été évaluées sur le plan de la cytocompatibilité, de l'adhérence et de la prolifération avec un modèle de cellules endothéliales animales. Ce travail vise aussi à optimiser l'adhérence de ces fibres sur le PET par l'emploi d'une technique de modification de surface par plasma. Les résultats montrent qu'il est possible de produire des nanofibres de PLA et de contrôler leur diamètre, et de sceller la paroi de la prothèse textile. Enfin, les cellules endothéliales prolifèrent en monocouche sur des prothèses recouve1tes de nanofibres. Il est possible d'optimiser l'adhérence des nanofibres sur le PET avec un traitement par plasma. En conclusion nous avons proposé une alternative à l'enduction traditionnelle des prothèses permettant la prolifération en monocouche des cellules endothéliales. / Textile vascular prostheses show poor patency rate for smaller diameter grafts (6-8mm). Mainly due to thrombosis or hyperplasia, graft failures can be explained by meagre hemocompatibility. Lack of neoendothelialization of the inner wall of the graft can be one reason explaining this poor hemocompatibility, This project aimed to prove that bare textiles are not a good support to stand endothelial cells' proliferation. Poly(L-latic) acid was therefore chosen to replace protein coating by being formed as a nanofibres mesh on the PET textile prostheses luminal surface. Air jet spinning process was first evaluated in a basic planar model to determined optimal parameters for nanofibres production. Endothelial cells compatibility, adhesion and proliferation were tested. Then air jet spinning was dedicated to tubular shape of textile vascular prostheses. Nanofibres mesh were analysed for chemical and physical properties, and covered graft were tested for water permeability. Lastly, atmospheric pressure plasma treatment was performed to optimize PLLA nanofibres adhesion on PET. Results showed that nanofibre diameters were controlled by polymer concentration. Nanofibre cristallinities depend of spinning parameters. Air jet spinning allows quick covering of textile surfaces with a dense net of nanofibre scelling the inner wall of the prosthesis, even in tubular samples. Moreover, endothelial ceIls show monolayer proliferation on these nanofibres. Finally, Polylactic acid adhesion on PET was optimized with atmospheric pressure plasma. In conclusion, we bring a new solution to cover inner wall of prostheses, allowing a monolayer proliferation of endothelial cells.
4

Evaluation du traitement antibiotique des infections de prothèse vasculaire à Staphylococcus aureus : apport d'un modèle murin / Assessment of different antibiotic therapies in a murine model of Staphylococcus aureus vascular prosthesis infection

Revest, Matthieu 16 December 2015 (has links)
Les infections de prothèses vasculaires (IPV) sont des maladies particulièrement graves. Malgré une fréquence finalement assez importante, elles demeurent mal connues. Staphylococcus aureus en est l’agent responsable principal. Les données concernant le traitement antibiotique à administrer pour ces infections sont excessivement pauvres. L’objectif de notre travail était donc de comparer l’efficacité de différents protocoles d’antibiothérapie à l’aide de divers modèles expérimentaux d’IPV. Six souches différentes de S. aureus ont été évaluées : 3 sensibles (SAMS) et 3 résistants à la méticilline (SARM). Nous avons comparé les concentrations minimales inhibitrices et éradicatrices (CMIB et CMEB) au sein du biofilm obtenues avec des techniques classiques sur polystyrène à ceux obtenus à l’aide d’un modèle original in vitro sur Dacron® (dCMIB et dCMEB) ®. Nous avons ensuite utilisé un modèle original d’infection de Dacron chez la souris pour comparer l’efficacité de différents protocoles thérapeutiques. Enfin nous avons visualisé l’effet de ces antibiotiques in vivo par microscopie confocale. Nous avons montré que les mesures classiques de CMIB et CMEB obtenues sur polystyrène pouvaient surestimer la baisse d’efficacité des antibiotiques dans le biofilm et que des mesures sur le matériel d’intérêt pouvaient être plus pertinentes. Dans notre modèle in vivo, la daptomycine pouvait être supérieure que les comparateurs pour certaines souches de SARM et de SAMS mais pas pour toutes. Par contre, si l’ajout de rifampicine était bénéfique pour la cloxacilline et la vancomycine, cela n’était pas le cas pour la daptomycine. Enfin, nous avons visualisés des effets totalement différents sur le biofilm selon les antibiotiques utilisés mais également selon les souches testées. Nos modèles ont permis d’obtenir des informations nouvelles concernant l’antibiothérapie des IPV qui, nous l’espérons, permettront d’aider à la prise en charge des patients. / Prosthetic vascular graft infection (PVGI) is an emerging disease, mostly due to staphylococci, with limited data regarding efficacy of current antistaphylococcal agents. We aimed to assess the efficacy of different antibiotic regimens. Six different strains of methicillin-susceptible (MSSA) and methicillin-resistant S. aureus (MRSA) were used. We compared results of minimal biofilm inhibitory and eradicating concentrations (MBICs and MBECs) obtained with a Calgary Biofilm Pin lid Device (CBPD) to those yielded by an original Dacron®-related minimal inhibitory and eradicating concentrations measure model. We then used an original murine model of Staphylococcus aureus vascular material infection to evaluate efficacy of different antibiotic regimens. We finally visualized the effect of antibiotics on biofilm by confocal microscopy. We demonstrated that classical measures of MBICs and MBECs with CPBD could overestimate the decrease of antibiotic susceptibility in material related infections and that the nature of the support used to measure biofilm susceptibility might be influent since results yielded by our Dacron®-related minimal eradicating assay were lower than those found on a plastic device. In our in vivo model, we shown that daptomycin was significantly more bactericidal than comparators for some strains of MRSA or MSSA but not for all. For the majority of strains, it was as efficient as comparators. The addition of rifampicin to daptomycin did not enhance daptomycin efficacy in our model. Finally, we highlighted an in vivo differential effect on biofilm depending on the antibiotic used but also on the bacterial strain evaluated. Our models represent an option to better define the best antibiotic options for PVGIs.
5

Utilisation d'une décharge à barrière diélectrique pour développer une matrice polymère plasma dégradable pour des applications vasculaires / Using a dielectric barrier discharge to develop a degradable plasma polymer matrix for vascular applicationsg

Laurent, Morgane 03 November 2017 (has links)
Chaque année, environ 1,5 million de patients requièrent un remplacement vasculaire en réponse à une athérosclérose avancée, causant le rétrécissement interne des vaisseaux sanguins. Malheureusement, encore aujourd'hui les matériaux synthétiques utilisés pour remplacer les artères de petits diamètres (inférieurs à 6 mm) restent associés à un haut taux d'échecs, démontrant ainsi un manque de biocompatibilité certain. L'une des principales complications observées est l'hyperplasie néointimale artérielle caractérisée par l'obstruction du vaisseau sanguin due à la prolifération tridimensionnelle de cellules sur la paroi interne de la prothèse. Différentes stratégies visant à limiter cette réaction naturelle sont aujourd'hui envisagées, notamment l'utilisation d'un système à libération contrôlée de médicament intégré localement aux prothèses vasculaires. En parallèle, l'essor des technologies plasma a permis de montrer qu'il était possible de revêtir la surface de matériel biomédical pour améliorer son interaction avec un environnement biologique. La stratégie consiste à utiliser l'énergie et la réactivité d'un plasma pour polymériser un précurseur gazeux. En sélectionnant la structure moléculaire du précurseur et les conditions expérimentales du plasma appropriées, il est possible de déposer un polymère plasma à la surface du matériel sélectionné pour lui conférer des propriétés sur mesure. C'est dans ce contexte que cette thèse a consisté à synthétiser, à l'aide d'un plasma, une matrice polymère plasma biodégradable pour revêtir la paroi interne d'une prothèse vasculaire, dans le but d'y incorporer un médicament choisi de façon à limiter l'hyperplasie néointimale. Ce projet a permis d'une part de réaliser une preuve de concept en déposant un revêtement polymère plasma dégradable par décharge à barrière diélectrique en configuration planaire. En utilisant le lactate d'éthyle en tant que précurseur et après de nombreuses analyses, des conditions de dépôt optimales ont pu être élues pour leur potentiel dans le cadre d'applications vasculaires. D'autre part, grâce à une caractérisation approfondie de la décharge, une corrélation étroite entre la physico-chimie du plasma et les dépôts dégradables obtenus a pu être établie. Afin d'élargir les possibilités de vitesse de dégradation, l'influence d'une alimentation impulsionnelle sur la décharge et sur le dépôt a de plus été étudiée. Si la manière d'apporter l'énergie a eu une forte influence sur la décharge, aucune influence majeure n'a été notée sur la chimie et la morphologie des dépôts faits à partir de lactate d'éthyle. Enfin, la construction d'un réacteur plasma tubulaire permettant de déposer la matrice développée à l'intérieur de prothèses artérielles a permis de s'étendre aux conditions réelles de dépôt. Dans l'ensemble, ce projet de recherche a mis en évidence le potentiel des procédés plasma pour le développement de matrices polymères plasma dégradables, notamment dans le cadre de systèmes à libération contrôlée et locale de médicaments pour des applications en chirurgie vasculaire. D'un point de vue de la physique des plasmas, ce travail a de plus souligné l'importance de l'étude de la décharge dans de véritables conditions de dépôt de couches minces. / Every year, about 1.5 million patients need a vascular replacement due to advanced arteriosclerosis, which causes the internal narrowing of blood vessels. Unfortunately, even today the synthetic materials used to replace small diameter arteries (below 6 mm) remain associated with low patency rate, which demonstrates an evident lack of biocompatibility. One of the main observed complications is arterial neointimal hyperplasia, which is characterized by the blood vessel obstruction due to the tridimensional proliferation of cells on the graft internal wall. Different strategies aiming at limiting this body reaction are currently considered, in particular the use of a drug delivery system locally integrated to the vascular grafts. Concurrently, the rise of plasma technologies enabled to demonstrate the possibility to coat the surface of biomedical devices to improve their interaction with a biological environment. The strategy consists in using the plasma energy and reactivity to polymerize a gaseous precursor. By selecting the appropriate precursor molecular structure and plasma experimental conditions, one can build up a plasma polymer with tailored properties. It is in this context that this thesis consisted in synthesizing, using plasma, a biodegradable polymeric plasma polymer matrix to coat the internal wall of a vascular graft, with the goal to incorporate a drug chosen to limit neointimal hyperplasia. On one hand, this project acted as proof of concept by developing a degradable plasma polymer coating using a planar dielectric barrier discharge. After extensive studies using ethyl lactate as precursor, optimal chemical vapor deposition conditions were elected for their potential in terms of vascular applications. On the other hand, thanks to an extended discharge characterization, a strong correlation was established between the plasma physico-chemistry and the properties of the degradable coatings synthesized. In addition, to broaden possibilities in terms of degradation rate, the influence of a squared pulse power supply on the discharge and the coating was studied. If changing the way to bring the energy had a strong influence on the discharge, no major influence was noticed on the ethyl lactate-based coatings' chemistry and morphology. Finally, a tubular plasma reactor was build up to empower the internal wall of vascular prosthesis to be coated, which enabled to extend this project to the deposition conditions of its final application. Overall, this research project highlighted the potential of plasma processes for the development of degradable plasma polymer matrices, particularly for local drug delivery systems for vascular applications. On a physics perspective, this work emphasized the importance of studying the discharge under actual thin layer deposition conditions.

Page generated in 0.0604 seconds